Home

User manual

image

Contents

1. EQUITEL Technical Manual N965 99 M 10 100Base TX Cable Schematic The following two figures show the 10 100Base TX cable schematic Switch Router or PC 3 TD 3 RD 6 TD gt z 6 RD 1 RD 1 TD 2 BD TD Straight through cable schematic Switch Switch 3 TD 3 TD 6 TD 6 TD RD RD 2 RD 2 RD Cross over cable schematic B 10 100 1000Base TX Pin outs The following figure shows the 10 100 1000 Ethernet RJ 45 pin outs 12345678 TPO Te TP TP3 mq gi amp hM EQUITEL Technical Manual N965 100 D EQUITEL B 10 100 1000Base TX Cable Schematic Switch Router 1 TP1 TPO TPO m m E gg 4 TP3 5 7 TP2 8 TP2 oM on b 3 3 Straight through cables schematic Switch Switch 1 1 TPO 2 TPO 2 TPO 3 1 3 1 1 TP1 4 TP2 4 TP2 5 TP2 5 TP2 7 TP3 7 TP3 a TP3 8 TP3 Cross over cables schematic EQUITEL Technical Manual N965 Jan 2013 Ed 2 01 101 D RJ 45 Pin Assignment of PoE With 100BASE TX 10BASE T cable pins 1 and 2 are used for transmitting data and pins 3 and 6 for receiving data pins 4 5 7 and 8 are used for power supplying m Pin out of Cisco non 802 3af standard PD EM SEM RX x RX TX VCC VCC TX VCC VCC
2. B Pin out of PoE Midspan Hub Switch TX VCC VCC TX VCC VCC EQUITEL Technical Manual N965 102 B Pin out of PoE Endspan Hub Switch EN WEN 1 TX VCC 2 TX VCC 3 TX VCC 4 5 6 TX VCC 7 8 Note and signs represent the polarity of the wires that make up each wire pair Before you power PD please check the RJ 45 connector pin assignment follow IEEE802 3af standard otherwise you may need to change one of the RJ 45 connector pin assignment attached with the UTP cable EQUITEL Technical Manual N965 103 CQUITEL Jan 2013 Ed 2 01 Appendix B Command Sets Commands Set List User EXEC E Privileged EXEC P Global configuration G VLAN database V Interface configuration Netstar Commands Level Description Example enable E Enter Privileged EXEC switch enable mode quit E Logout command line switch gt quit shell show E Show switch switch gt show config configuration uptime E Show system up time switch gt uptime disable P Leave Privileged switch gt enable EXEC mode switch disable configure P Enter Global switch gt enable configuration mode switch configure end G Leave Global switch gt enable configuration mode switch config end exit G Leave Global switch gt enable configuration mode switch config exit Switch Setting Commands Set Netstar Commands Level Description Example show terminal P S
3. qos priority G Configure COS Port switch enable cosportdefault default switch configure Port Priority switch config qos priority cosportdefault 1 1 qos priority tos G Configure TOS Priority switch gt enable Priority lowest low mid switch configure dle high switch config qos priority tos 3 show qos P Displays the eic sss information of QoS switch configure configuration switch show qos no gos G Disable QoS function switch enable switch configure switch config no qos IGMP Commands Set Netstar Commands Level Description Example igmp enable G Enable IGMP switch gt enable snooping function switch configure switch config igmp enable igmp query G Configure IGMP query switch gt enable auto fource mode switch configure switch config igmp query auto igmp unregister G Configure IGMP switch gt enable flooding blocking sourc unregister stream switch configure eonly switch config igmp unregister flooding igmp last query count G Configure Last switch gt enable 1 2 sec Member Query Count switch configure switch config igmp last query count 1 igmp last query interval G Configure Last switch gt enable 1 250 tenths of a sec Member Query switch configure Interval switch config igmp last query EQUITEL Technical Manual N965 123 CQUITEL Jan 2013 Ed 2 01 interval 100 igmp query interval G Configure Query switch gt enable 1 250 sec Interval switch configu
4. 41 SNMP Agent 41 6 20 1 SNMP Trap Configuration 43 6 10 System Alert Relay Alarm 44 6 8 1 System Alert SMTP 44 6 8 2 System Alert 46 6 11 DHCP Server 48 6 6 1 DHCP Server Server configuration 48 6 6 2 Client Table 49 6 6 3 IP BIndl0S PE cU 49 6 12 Port Configuration 51 6 13 Porn 2 52 6 14 POM SlAUSUCS ambas Sob etait 54 6 15 Port Port Alert 56 6 16 Rate Control Rate 57 6 17 Aggregation Configuration 59 EQUITEL Technical Manual N965 Jan 2013 Ed 2 01 CQUITEL 6 17 1 Configuration 60 6 17 2 Aggregator Status 62 6 18 Spanning Tree 63 6 18 1 RSTP SONG bene Up as 63 6 18 2 RSTP Information 65 6 19 Pro Ring S 66 6 20 Multicast 68 6 21 T z
5. 04 o Port os gt Portos o gt 6 25 4 DSCP mapping to queue Set up the DSCP priority With the drop down selection item of Priority Type above being selected as DSCP only SDCP first this control item will then be available to set the queuing policy for each port m DSCP priority The system provides 0 63 DSCP priority level Each level has 4 types of priority High Middle Low and Lowest The default value is Lowest priority for each level When the IP packet is received the system will check the DSCP level value in the IP packet that has received For example the user sets the DSCP level 25 as high the system will check the DSCP value of the received IP packet If the DSCP EQUITEL Technical Manual N965 82 D value of received IP packet is 25 priority high and then the packet priority will have highest priority W Click Apply to have the configuration take effect QoS DSCP Mapping to Queue Priority Setting DSCP 0 al 2 3 4 5 6 Priority Lowest Lowest ort M Lowest y Lowest m Lowest al Lowest EIL DSCP 8 10 Priority Lowest 7 Lowest EI Ss x Lowest lt Lowest Lowest EIE x DSCP 16 Priority Low Low E Low Low E Low Low E Low Low DSCP 24 Priority Low Low Low x Low Low x Low Low Low x DSCP 32 Priority Middle Sas Sas a a a Sas sas y DSCP 40 Priority Midd
6. EQUITEL Technical Manual N965 52 Port Status Type 100TX 100TX 100TX 100TX 100TX 100TX 100TX 100TX EQUITEL Technical Manual N965 Link State Speed Duplex Flow Control Down Enable N A Down Enable N A Down Enable N A Down Enable N A Down Enable N A UP Enable 100 Full Down Enable N A Down Enable 1GTX SFP Down Enable N A 1GTX SFP Down Enable N A N A N A N A N A N A Enable N A N A N A N A Jan 2013 Ed 2 01 53 6 14 Port Statistics The following chart provides the current statistic information which displays the real time packet transfer status for each port The user might use the information to plan and implement the network or check and find the problem when the collision or heavy traffic occurs m Port The port number Type Displays the current speed of connection to the port m Link The status of linking or Down W State It s set by Port Control When the state is disabled the port will not transmit or receive any packet Tx Good Packet The counts of transmitting good packets via this port Tx Bad Packet The counts of transmitting bad packets including undersize less than 64 octets oversize CRC Align errors fragments and jabbers packets via this port Rx Good Packet The counts of receiving good packets via this port Rx Bad Packet The counts of receiving good packets including undersize less than 64 octets oversize CRC e
7. Technical Manual N965 48 exe DHCP Server Server Configuration Jan 2013 Ed 2 01 DHCP Setting DHCP Server Disable Start IP Address 192 168 16 2 End IP Address 192 168 16 200 Subnet Mask 255 255 255 0 Gateway 192 168 16 254 DNS oo Lease Time Hour 6 6 2 Client Table When the DHCP server function is enabled the system will collect the DHCP client information including the assigned IP address the MAC address of the client device the IP assigning type status and lease time Server Client Table IP Address MAC Address Type Status Lease 6 6 3 IP Bindings Assign the dynamic IP address bound with the port to the connected client The user is allowed to fill each port column with one particular IP address When the device is connecting to the port and asks for IP assigning the system will assign the IP address bound with the port EQUITEL Technical Manual N965 49 EQUITEL Technical Manual N965 Jan 2013 Ed 2 01 50 Jan 2013 Ed 2 01 CQUITEL 6 12 Port Configuration In Port control you can configure the settings of each port to control the connection parameters and the status of each port is listed beneath Port No The port number which you want to be configured m State Current port state The port can be set to disable or enable mode If the port state is set as Disable it will not receive or transmit any packet
8. 1000M Green External Power Supply DC 12 48V Redundant power DC LED Power Supply 12 48V and connective removable terminal block for master and slave power Power 9 86 W at full load Consumption Operating m 596 to 9596 Non condensing Humidity Operating 40 C 75 Temperature Storage 40 C 85 C Temperature Case Dimension IP 30 72mm W x 105mm D x 152mm H Installation DIN rail and wall mount ear FCC Class A CE EN61000 4 2 CE EN61000 4 3 CE EN 61000 4 4 CE EN61000 4 5 CE EN61000 4 6 CE EN61000 4 8 CE EN61000 4 11 CE EN61000 4 12 CE EN61000 6 2 CE EN61000 6 4 Safety UL cUL CE EN60950 1 1 60068 2 32 Free fall 60068 2 27 Shock Stability Testing IEC60068 2 6 Vibration EQUITEL Technical Manual N965 CQUITEL Jan 2013 Ed 2 01 1 2 Software Features Management SNMP MIB Port Trunk with LACP Spanning tree Pro Ring2s Quality of Service Class of Service Port Security SNMP v1 v2c v3 Web Telnet CLI RFC 1215 Trap RFC1213 MIBII RFC 1157 SNMP MIB RFC 1493 Bridge MIB RFC 2674 VLAN MIB RFC 1643 RFC 1757 RSTP MIB Private MIB LLDP MIB Port Based VLAN IEEE 802 1Q Tag VLAN 256 entries VLAN ID Up to 4K VLAN ID can be assigned from 1 to 4094 GVRP 256 Groups LACP Port Trunk 4 Trunk groups Maximum 4 trunk members Supports LLDP allowing switch to advertise its identif
9. EQUITEL Technical Manual N965 mam Ful gi Jan 2013 Port Port Alert SMTP 6 16 Rate Control Rate Limit You can set up every port s bandwidth rate and frame limitation type All the ports support port egress rate control For example assume port 1 is 10Mbps users can set it s effective egress rate is 1Mbps ingress rate is 500Kbps The switch performs the ingress rate by packet counter to meet the specified rate m Andthen click Apply to apply the settings EQUITEL Technical Manual N965 57 exe Rate Control Rate Limit Jan 2013 Port No Egress 01 n kbps Port o2 D kbps Port 03 n kbps Port o4 0 kbps Port 05 n kbps 0 kbps Por 07 D kbps Port 08 o kbps B Storm Control select the frame type that wants to filter There are four frame types for selecting All Broadcast Multicast Flooded Unicast Broadcast Multicast Broadcast only Broadcast Multicast Flooded Unicast Broadcast Multicast and Bbroadcast only types are only for ingress frames The egress rate only supports All type Andthen click Apply to apply the settings EQUITEL Technical Manual N965 58 Jan 2013 o Rate Control Storm Control Port No Ingress Limit Frame Type Ingress Potoi al _ m keps Pato a mo Potoa ja m o Port o4 I ro koes Potos fal
10. Enable Telnet Management Z Enable SNMP Management Apply Help 85 EQUITEL Technical Manual N965 Jan 2013 Ed 2 01 6 26 2 IP Source Guard Static Table Security IP 1 10 The system allows the user to assign up to 10 specific IP addresses for access security Only these 10 IP addresses can access and manage the switch through the HTTP Telnet service once IP Security Mode is enabled m Andthen click Apply to have the configuration take effect NOTE Remember to execute the Save Configuration action otherwise the new configuration will lose when the switch powers off IP Source Guard Configuration Configuration Static Table IP List Settings Secure 1 ppop Secure 1 2 5520 Secure JOGO Secure 1 4 pooo Secure IPS poon SecueIP6 1000 Secure IP7 ooo Secure 1 8 ioon Secure IP9 nooo Secure IP10 pooo EQUITEL Technical Manual N965 86 fm eauirel m Jan 2013 Ed 2 01 6 26 3 802 1X Radius 802 1x is an IEEE authentication specification which prevents the client from accessing a wireless access point or wired switch until it provides authority like the user name and password that are verified by an authentication server such as RADIUS server After enabling the IEEE 802 1X function you can configure the parameters of this function 6 26 3 1 Configuration IEEE 802 1x Protocol Enable or disable 802 1x protocol Radius Server IP
11. WB Speed Diplex It can be set as auto or set speed and negotiated way manually Flow Control Whether or not the receiving node sends feedback to the sending node is determined by this item When enabled once the device exceeds the input data rate of another device the receiving device will send a PAUSE frame which halts the transmission of the sender for a specified period of time When disabled the receiving device will drop the packet if too much to process m Alies Add description of each port to let the manager know the connected device of each port it will be showed by NMS utility to have the configuration take effect B Click Apply EQUITEL Technical Manual N965 51 exe Port Configuration Jan 2013 Ed 2 01 State Speed Duplex Flow Control Alias Enable v autoNegotiaton gt Symmetrie zl 000 Enable v auteNegotiation Symmetrie l Enable v auteNegotiation Symmetrie l 0000000 Enable v auteNegotiation Symmetrie l Enable 2 AutoNegotiation Symmetrie l 1 Enable v autoNegotiation Symmetrie zl 000 Enable autoNegotiation gt Symmetrie zl 00001 Enable AutoNegotiation gt Symmetrie zl 0001 Enable gt AutoNegotiation gt Symmetrie zl 0001 SFP Setting Auto Detect 100 1000 SFP Enable Port Control interface 6 13 Port Status It will Show you the status of port configuration setting
12. event type switch gt enable switch configure switch config event device restart both event authentication failure Sysog SMTP Both Set Authentication failure event type switch gt enable switch configure switch config event EQUITEL Technical Manual N965 131 CQUITEL Jan 2013 Ed 2 01 authentication failure both event syslog Set port event for switch gt enable Link UP Link SYSLOG switch configure Down Both switch config interface fastethernet 3 switch config if event syslog both event smtp Set port event for switch gt enable Link UP Link SMTP switch configure Down Both switch config interface fastethernet 3 switch config if event smtp both show event Show event selection switch gt enable switch show event no event device restart Syslog SMTP Both Disable device restart event type switch gt enable switch configure switch config no event device restart both no event authentication failure Syslog SMTP Both Disable Authentication failure event typ switch gt enable switch configure switch config no event authentication failure both no event syslog Disable port event for system log switch gt enable switch configure switch config interface fastethernet 3 switch config if no event syslog no event smpt Disable port event for SMTP switch gt enable switch configure switch conf
13. Assign the RADIUS Server IP address Server Port Set the UDP destination port for authentication requests to the specified RADIUS Server WB Accounting Port Set the UDP destination port for accounting requests to the specified RADIUS Server m Shared Key Set an encryption key for using during authentication sessions with the specified RADIUS server This key must match the encryption key used on the RADIUS Server B Identifier Set the identifier for the RADIUS client Quiet Period Set the period which the port doesn t try to acquire a supplicant TX Period Set the period the port waits for retransmit next EAPOL PDU during an authentication session B Timeout Set the period of time the switch waits for a supplicant response to an EAP request Server Timeout Set the period of time the switch waits for a server response to an authentication request m Requests Set the number of authentication that must time out before authentication fails and the authentication session ends m Reauth period Set the period of time which clients connected must be re authenticated B Click Apply EQUITEL Technical Manual N965 87 Le 6 26 You 802 1x Radius Configuration Radius Server Setting 802 1x Protocol Disable Radius Server 192 168 16 3 Server Port Accounting Port Shared Key 2345678 NAS Identifier 5 l2 SWITCH J Advanced Setting 7
14. Example ratelimit type all Set interface ingress limit frame type to accept all frame switch gt enable switch configure switch config interface fastEthernet 2 switch config if ratelimit type all EQUITEL Technical Manual N965 112 CQUITEL Jan 2013 Ed 2 01 ratelimit type broadcast multicast flooded unicast Set interface ingress limit frame type to accept broadcast multicast and flooded unicast frame switch gt enable switch configure switch config interface fastEthernet 2 switch config if ratelimit type broadcast multicast flooded unicast ratelimit type broadcast multicast Set interface ingress limit frame type to accept broadcast and multicast frame switch gt enable switch configure switch config interface fastEthernet 2 switch config if ratelimit type broadcast multicast ratelimit type broadcast Set interface ingress switch gt enable only limit frame type to switch configure only accept broadcast switch config interface frame fastEthernet 2 switch config if ratelimit type broadcast only ratelimit in Set interface input switch gt enable kbps bandwidth zero switch configure means no limit switch config interface fastEthernet 2 switch config if ratelimit in 160 ratelimit out Set interface output switch gt enable kbps bandwidth Rate switch configure Range is from 100 kbps to 102400
15. Quiet Period fo Tx Period o Supplicant Timeout E ServerTimeout F Max Requests RE sq si Re Auth Period pamm O 3 2 Port Setting can configure the 802 1x authentication state for each port The state provides Disable Accept Reject and Authorize Reject The specified port is required to be held in the unauthorized state Accept The specified port is required to be held in the authorized state Authorize The specified port is set to the Authorized or Unauthorized state in accordance with the outcome of an authentication exchange between the Supplicant and the authentication server Disable When disabled the specified port works without complying with 802 1x protocol EQUITEL Technical Manual N965 88 Jan 2013 Ed 2 01 Click Apply 802 1x Radius Port Settings Port Authorize Mode 6 26 3 3 Port Status You can monitor the port Authorized state in this function EQUITEL Technical Manual N965 89 Jan 2013 Ed 2 01 802 1x Radius Port Status Port Authorize State Accept Accept Accept Accept Accept Accept Accept Accept Accept Accept EQUITEL Technical Manual N965 90 6 26 4 MAC Filtering Jan 2013 Ed 2 01 You can block the un authorized MAC by switch in this function EQUITEL Technical Manual N965 91 EQUITEL i Jan 2013 Ed 2 01 6 26 5 Port Security You can block the un authorized MAC by oer port in t
16. Zone 9 IDLE International Date Line NZST New Zealand 12 hours Midnight Standard NZT New Zealand B SNTP Sever Address Set the SNTP server IP address You can assign a local network time server IP address or an internet time server IP address Daylight Saving Time This is used as a control switch to enable disable daylight saving period and daylight saving offset Users can configure Daylight Saving Period and Daylight Saving Offset in a certain period time and offset time while there is no need to enable daylight saving function Afterwards users can just set this item as enable without assign Daylight Saving Period and Daylight Saving Offset again B Daylight Saving Period Set up the Daylight Saving beginning date time and Daylight Saving ending date time Please key in the value in the format of YYYYMMDD and HH MM leave a space between YYYYMMDD and HH MM gt YYYYMMDD an eight digit year month day specification gt HH MM five digit including a colon mark hour minute specification For example key 20070701 02 00 and 20071104 02 04 in the two column fields respectively to represent that DST begins at 2 00 a m on March 11 2007 and ends at 2 00 a m on November 4 2007 m Daylight Saving Offset For non US and European countries specify the amount of time for day light savings Please key in the valid figure in the range of minute between 0 and 720 which means you can set the offset
17. interface static switch gt enable switch configure switch config interface fastEthernet 2 switch config if mac address table static hwaddr 000012345678 show mac address table static Show MAC address table static switch gt enable switch show mac address table static no mac address table static hwaddr HW Addr Remove an entry of MAC address table of interface static switch gt enable switch configure switch config interface fastEthernet 2 switch config if no mac address table static hwaddr 000012345678 MAC Blacklist Commands Set Netstar Commands Level Description Example mac address table filter G Configure MAC switch gt enable hwaddr HW Addr address entry of interface filter switch configure switch config mac address table filter hwaddr 000012348678 EQUITEL Technical Manual N965 126 CQUITEL Jan 2013 Ed 2 01 show mac address table P Show MAC address switch gt enable filter table filter switch show mac address table filter no mac address table G Remove an entry of switch enable filter hwaddr MAC address table switch configure HW Addr filter switch config no mac address table filter hwaddr 000012348678 802 1x Commands Set Netstar Commands Level Description Example 8021x enable G Enable IEEE802 1x switch gt enable function switch configure switch config 802
18. port PortNumbers plfc Enable Disable Set PoE port Power Limit from Classification switch gt enable switch poe switch poe port 1 plfc enable port PortNumbers legacy Enable Disable Set PoE port Legacy switch gt enable switch poe switch poe port 1 legacy enable port PortNumbers priority Low High Critical Set PoE port Priority switch gt enable switch poe switch poe port 1 priority high autoping enable Set PoE auto ping Enable switch gt enable switch poe switch poe autoping enable autoping sendmail enable Set PoE auto ping Send Mail switch gt enable switch poe switch poe autoping sendmail enable port PortNumbers Set PoE schedule switch gt enable EQUITEL Technical Manual N965 136 CQUITEL Jan 2013 Ed 2 01 schedule enable Configuration switch poe switch poe port 1 schedule enable port PortNumbers schedule day 0 6 e g 0 Sun 6 Sat hour 0 23 power On Down P Set PoE schedule date day switch gt enable switch poe switch poe port 1 schedule day 5 hour 21 power on switch poe port 1 schedule day 0 1 hour 0 3 power on switch poe port 1 schedule day 0 4 hour 0 3 5 power on show poe autoping P Show PoE auto ping information switch gt enable switch poe switch show poe autoping show poe schedule P Show PoE schedule information switch gt enable switch poe switch
19. 08 Disable v Disable Disable EQUITEL Technical Manual N965 73 9 EQUITEL 01 ex 6 23 1 Dynamic MAC table You can monitor the learning status of MAC address table in this function Filtering Data Base Dynamic Table Dynamic Address Count D Static Address Count 0 EQUITEL Technical Manual N965 Jan 2013 74 6 24 VLAN A Virtual LAN VLAN is a logical network grouping that limits the broadcast domain which would allow you to isolate network traffic so only the members of the same VLAN will receive traffic from the ones of the same VLAN Basically creating a VLAN on a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch However all the network devices are still plugged into the same switch physically This switch supports Port based and 802 1Q tagged based VLAN The default configuration of VLAN operation mode is Disable 6 24 1 VLAN Configuration m Operation Mode Enter the MAC address of the port that should permanently forward traffic regardless of the device network activity Configuration VLAN Mode Setting Operation Mode 802 10 Disable Port Based EQUITEL Technical Manual N965 75 m 802 1Q VLAN Setting Enable GVRP mode and define the Management VLAN ID GVRP GARP VLAN Registration Protocol or Generic VLAN Registration Protocol is a protocol
20. Web Management Before using the web management install the industrial switch on the network and make sure that any one of the PCs on the network can connect with the industrial switch through the web browser The industrial switch default value of IP subnet mask username and password are listed as below IP Address 192 168 16 1 Subnet Mask 255 255 255 0 Default Gateway 192 168 16 254 User Name root Password root EQUITEL Technical Manual N965 29 Jan 2013 Ed 2 01 EQUITEL 6 3 System Login Launch the Internet Explorer on the PC Key in http the IP address of the switch and then Press Enter 1 2 File Edit View Favorites Tools Help z ix E TN JO Search Favorites Address http 192 168 16 1 The login screen will appear right after 4 Key in the user name and password The default user name and password are the Press Enter or click the OK button and then the home screen of the Web based D same as root 5 management appears Connect to 192 168 16 1 index htm root User name Password Login screen 30 EQUITEL Technical Manual N965 6 4 System 6 4 1 General Switch Information User can find the system name description location and contact personnel to identify the switch The version table below is a read only field to show the basic information of the switch B System Name Assign the
21. encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver m Connect the equipment into an outlet on a circuit different from that to which the receiver is connected W Consult the dealer or an experienced radio TV technician for help CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures EQUITEL Technical Manual N965 Chapter 1 Introduction The 8 10 100TX 2 10 100 1000T Dual Speed SFP Combo Managed Industrial Switch is a cost effective solution and meets the high reliability requirements demanded by industrial applications Using fiber port can extend the connection distance that increases the network elasticity and performance 1 1 Hardware Features IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX FX IEEE802 3ab 1000Base T IEEE802 3z Gigabit fiber IEEE802 3x Flow Control and Back Pressure IEEE802 3ad Port trunk with LACP IEEE802 1d Spanning Tree IEEE802 1w Rapid Spanning Tree IEEE802 1p Class of Service IEEE802 1Q VLAN Tag IEEE 802 1x User Authentication Radius IEEE802 1ab LLDP Switch Back plane Switching Fabric 7 4Gbps Architecture Packet throughput ability Full Duplex 8 3Mpps 64bytes 14 880pps for Ethernet port Standard Transfer Rate 14
22. high IP switch gt enable High IP address for IP pool switch configure switch config dhcpserver highip 192 168 1 200 dhcpserver subnetmask Configure subnet switch gt enable Subnet mask mask for DHCP clients switch configure switch config dhcpserver subnetmask 255 255 255 0 dhcpserver gateway G Configure gateway for switch gt enable Gateway DHCP clients switch configure switch config dhcpserver gateway 192 168 1 254 dhcpserver dnsip G Configure DNS IP for switch enable DNS IP DHCP clients switch configure switch config dhcpserver dnsip 192 168 1 1 dhcpserver leasetime G Configure lease time switch gt enable Hours Hours switch configure switch config dhcpserver leasetime 1 dhcpserver ipbinding IP address Set static IP for DHCP clients by port switch gt enable switch configure EQUITEL Technical Manual N965 109 Jan 2013 Ed 2 01 switch config interface fastEthernet 2 switch config if dhcpserver ipbinding 192 168 1 1 show dhcpserver P Show configuration of switch gt enable configuration DHCP server switch show dhcpserver configuration show dhcpserver clients P Show client entries of switch gt enable DHCP server switch show dhcpserver clients show dhcpserver ip P Show IP Binding switch gt enable binding information of DHCP _ switch show dhcpserver ip server binding no dhcpserver G Disable DHCP server switch gt enable f
23. hybrid link untag 4 tag 3 6 8 or switch vlan vlan 8021q port 3 hybrid link untag 5 tag 6 8 vlan 8021q port PortNumber hybrid link qinq untag UntaggedVID tag TaggedVID List Assign a qing link for VLAN by port if the port belong to a trunk group this command switch gt enable switch vlan database switch vlan vlan 80214 port hybrid link qinq untag 4 tag EQUITEL Technical Manual N965 119 Jan 2013 Ed 2 01 can t be applied 3 6 8 or switch vlan vlan 80214 port hybrid link qinq untag 5 tag 6 8 vlan 8021q aggreator PortNumber access link untag UntaggedVID Assign a access link for VLAN by trunk group switch gt enable switch vlan database switch vlan vlan 8021q aggreator 3 access link untag 33 vlan 8021q aggreator PortNumber trunk link tag TaggedVID List Assign a trunk link for VLAN by trunk group switch gt enable switch vlan database switch vlan vlan 8021q aggreator 3 trunk link tag 2 3 6 99 or switch vlan vlan 80214 aggreator 3 trunk link tag 3 20 vlan 8021q aggreator PortNumber hybrid link untag UntaggedVID tag TaggedVID List Assign a hybrid link for VLAN by trunk group switch gt enable switch vlan database switch vlan vlan 80214 aggreator 3 hybrid link untag 4 tag 3 6 8 or switch vlan vlan 80214 aggreator 3 hybrid link untag 5 tag 6 8 vlan 8021q aggreator PortNumber hybrid link qinq un
24. member ports won t know that they should be aggregated together to form a logic trunk group Work ports This column field allows the user to choose the total number of active port up to four With LACP static trunk group e g you assign four ports to be the members of a trunk group whose work ports column field is set as two the exceed ports are standby redundant ports and can be aggregated if working ports fail If it is a static trunk group non LACP the number of work ports must equal the total number of group member ports B Click Apply EQUITEL Technical Manual N965 60 exi Aggregation Configuration Jan 2013 o m o Port No Group ID Type Port 01 None Static gt Port 02 None z Static gt Port 03 None Static Port 04 None z Static gt Port 05 None static None z Static gt Port 07 None Static Port ag None z Static gt Port 09 None static Port 10 None Static Note the types should be the same for all member ports in a group 802 3ad LACP Work Ports Group ID Work Ports Trunki max Trunk2 max Trunk3 max Trunk4 max w Port Trunk Aggregator Setting interface four ports are added to the left field with LACP enabled EQUITEL Technical Manual N965 61 EQUITEL 6 17 2 Aggregator Status You can check the setting of Port aggregation in Status Aggregation Status
25. of seconds a port waits before changing from its Rapid Spanning Tree Protocol learning and listening states to the forwarding state Enter a value between 4 through 30 Enable Select the port which you want to be enabled with RSTP Path Cost The cost of the path to the other bridge from this transmitting bridge at the specified port Enter a number 1 through 200 000 000 m Priority Decide which port should be blocked by setting its priority as the lowest Enter a number between 0 and 240 The value of priority must be the multiple of 16 P2P The rapid state transitions possible within RSTP are dependent upon whether EQUITEL Technical Manual N965 63 Le the port concerned can only be connected to exactly another bridge i e it is served by a point to point LAN segment or can be connected to two or more bridges i e it is served by a shared medium LAN segment This function allows the P2P status of the link to be manipulated administratively True means the port is regarded as a point to point link False means the port is regarded as a shared link Auto means the link type is determined by the auto negotiation between the two peers W Edge The port directly connected to end stations won t create bridging loop in the network To configure the port as an edge port set the port to True status B Click Apply RSTP RSTP Setting RSTP Mode Enable Bridge Setting Priority 0 61440 32768 Max Age Time 6
26. on this switch enable True False interface switch configure switch config interface fastEthernet 2 switch config if rstp admin edge false rstp admin non stp Admin NonSTP on this switch gt enable True False interface switch configure switch config interface fastEthernet 2 switch config if rstp admin non stp false show rstp G Show RSTP switch gt enable information switch show rstp EQUITEL Technical Manual N965 117 Jan 2013 Ed 2 01 no rstp G Disable RSTP switch gt enable switch configure switch config no rstp VLAN Commands Set Netstar Commands Level Description Example vlan database P Enter VLAN configure switch gt enable mode switch vlan database vlanmode portbase 802 1q diable gvrp To set switch VLAN mode switch gt enable switch vlan database switch vilan vlanmode portbase or switch vlan vlanmode 802 14 or switch vlan vlanmode disable or switch vlan vlanmode Ported based VLAN configuration vlan port based V Add new port based switch enable grpname VALN switch vlan database Group Name switch vlan vlan port based grpid grpname test grpid 2 port 2 4 GroupID or port switch vlan vlan port based PortNumbers grpname test grpid 2 port 2 3 4 show vlan GroupID V Show VLAN switch gt enable el information switch vlan database show vlan switch vlan show vlan 2 no vlan VID V Delete port bas
27. s o kbps Pot o6 I rb Porto7 Al lO kbps Portos Al dio kbps Potoo Al sb kbps ote Rate range is from 100 kbps to 102400 kbps i e 100Mbps for mega ports or 256000 kbps i e 250Mbps for giga ports Zero means no limit 6 17 Aggregation Configuration Port trunking is the combination of several ports or network cables to expand the connection speed beyond the limits of any one single port or network cable Link Aggregation Control Protocol LACP which is a protocol running on layer 2 provides a standardized means in accordance with IEEE 802 3ad to bundle several physical ports together to form a single logical channel All the ports within the logical channel or so called logical aggregator work at the same connection speed and LACP operation requires full duplex mode EQUITEL Technical Manual N965 59 Q 1 6 17 1 Configuration Group ID There are 5 trunk groups to be selected Assign the Group ID to the trunk group TYPE When choose LACP the trunk group is using LACP A port which joins an LACP trunk group has to make an agreement with its member ports first Please notice that a trunk group including member ports split between two switches has to enable the LACP function of the two switches When disabled the trunk group is a static trunk group The advantage of having the LACP disabled is that a port joins the trunk group without any handshaking with its member ports but
28. speed up to 1000 Mbps and you can prevent noise interference from the system Note SFP Copper Combo port can t both work at the same time The SFP port has the higher priority than copper port if you insert the 1000M SFP transceiver which has connected to the remote device via fiber cable into the SFP port the connection of the accompanying copper port will link down If you insert the 100M SFP transceiver into the SFP port even without a fiber connection to the remote the connection of the accompanying copper port will link down immediately EQUITEL Technical Manual N965 To connect the transceiver and LC cable please follow the steps shown below First insert the transceiver into the SFP module Notice that the triangle mark is the bottom of the module Triangle Mark ER Cr Transceiver to the SFP module Transceiver Inserted Second insert the fiber cable of LC connector into the transceiver EQUITEL Technical Manual N965 EQUITEL Technical Manual N965 LC connector to the transceiver Jan 2013 Ed 2 01 20 CQUITEL To remove the LC connector from the transceiver please follow the steps shown below Jan 2013 Ed 2 01 First press the upper side of the LC connector to release from the transceiver and pull it out Remove LC connector Second push down the metal loop and pull the transceiver out by the plastic handle Pull out from the transceiver EQUITEL T
29. system name of the switch The maximum length is 64 bytes System Description Describes the switch System Location Assign the switch physical location The maximum length is 64 bytes System Contact Enter the name of contact person or organization System OID SNMP OID of switch Firmware Version Displays the switch s firmware version Kernel Version Displays the kernel software version MAC Address Displays the unique hardware address assigned by manufacturer System Name N965 System Description 8 10 100TX 2 Gigabit Copper Mini GBIC Combo Managed Industrial Switch System Location EQUITEL System Contact nacional equitel es System OID 1 3 6 1 4 1 37072 303 2 2 Firmware Version v1 00 Kernel Version v3 00 03 Device MAC 28 60 46 A0 01 A4 System Time 7 1 1970 01 14 54 6 4 2 General Asset You can modify these information about System name gt System Description System Location and System Contact in here EQUITEL Technical Manual N965 31 Jan 2013 Ed 2 01 Switch Setting System Name 965 System Description 8 10 100TX 2 Gigabit Copper Mini GBIC Combo Managed Indus System Location EQUITEL System Contact nacional equitel es System OID 1 3 6 1 4 1 37072 303 2 2 Firmware Version v1 00 Kernel Version v3 00 03 Device MAC 28 60 46 A0 01 A4 Apply Switch settings interface 6 4 2 General CPU Load Average Sometimes the user was worry about that Could m
30. to the multicast group A message sent by a host to the querier to indicate that the Report host wants to be or is a member of a given group indicated in the report message Leave A message sent by a host to the querier to indicate that the Group host has quit being a member of a specific multicast group 6 20 1 IGMP Snooping The switch support IP multicast you can enable IGMP protocol on web management s switch setting advanced page then the IGMP snooping information displays IP multicast addresses range are from 224 0 0 0 through 239 255 255 255 B IGMP Protocol enable or disable the IGMP protocol IGMP Query enable or disable the IGMP query function The IGMP query information will be displayed in IGMP status section IGMP Unregister Stream let the switch know how to process the Multicast data stream which was unregistered with IGMP Query B Click Apply EQUITEL Technical Manual N965 68 Le Multicast Support IGMP Snooping _ IGMP System IGMP Snooping Disable IGMP Query Mode Disable IGMP Unregister Stream Source Only bpply Help _ IGMP Snooping Table 7 IP Address Member Port IGMP Configuration interface 6 20 2 Static Filtering Multicasts are similar to broadcasts they are sent to all end stations on a LAN or VLAN Multicast filtering is the function which end stations can receive the multicast traffic if the connected ports had been included
31. 102 Appendix B Command 104 Switch Setting Commands Set 104 Admin Password Commands Set 105 IP Setting Commands Set 105 SNTP Commands Set 106 LLDP Commands Set 107 Backup amp Restore Commands Set 108 Upgrade Firmware Commands Set 108 DHCP Server Commands 109 Port Control Commands 110 Port Status Commands Set 112 Rate Limit Commands 112 Trunk Commands Set 114 PRO RING IIS Commands Set 115 RSTP Commands Set 116 VLAN Commands Set 118 SNMP Commands Set 121 Traffic Prioritization Commands Set 122 IGMP Commands Set 123 Multicast Static Filtering Table Commands Set 124 IP Security Commands Set 125 EQUITEL Technical Manua
32. 1x enable 8021x system radiusip G Radius Server IP Use the 802 1x system radius IP global configuration command to change the radius server IP switch gt enable switch configure switch config 8021x system radiusip 192 168 1 1 8021x system serverport G Port Number Use the 802 1x system server port global configuration command to change the radius server port switch gt enable switch configure switch config 8021x system serverport 1815 8021x system G accountport Port Number Use the 802 1x system account port global configuration command to change the accounting port switch gt enable switch configure switch config 8021x system accountport 1816 8021x system sharedkey G SharedKey Use the 802 1x system share key global configuration command to change switch gt enable switch configure switch config 8021x system sharedkey 123456 EQUITEL Technical Manual N965 127 CQUITEL Jan 2013 Ed 2 01 the shared key value 8021x system nasid NAS ID Use the 802 1x system nasid global configuration command to change the NAS ID switch gt enable switch configure switch config 8021x system nasid test1 8021x misc quietperiod Seconds Use the 802 1x misc quiet period global configuration command to specify the quiet period value of the switch switch gt enable switch configure switch config 8021x misc quietperio
33. 3 user root password 123 123 EQUITEL Technical Manual N965 121 CQUITEL Jan 2013 Ed 2 01 no snmp community G Disable SNMP switch gt enable strings Community strings switch configure switch config no snmp community strings public no snmp trap server G Remove SNMP trap switch gt enable IP Address seing switch configure switch config no snmp trap server 192 168 1 120 no snmp snmpv3 user G Remove SNMPv3 switch gt enable password User prote switch configure Authentication switch config no snmp snmpv3 Password Privacy user root password 123 123 Password Traffic Prioritization Commands Set Netstar Commands Level Description Example qos prioritytype G Setting of QOS priority switch gt enable port based cos type switch configure only tos only cos switch config qos prioritytype first tos first port base qos policy G Select QOS policy switch gt enable weighted fair strict scheduling switch configure switch config qos policy weighted fair qos priority portbased G Configure Port based switch gt enable Pon Priority switch configure switch config qos priority portbased 1 low qos priority cos G Configure COS switch gt enable t nory Priority switch configure dle high switch config qos priority cos 0 middle EQUITEL Technical Manual N965 122 CQUITEL Jan 2013 Ed 2 01
34. 40 20 Hello Time 1 10 2 Forward Delay Time 4 30 15 Port Setting Path Cost O auto Priority No Enable 200000000 0 240 Port O1 enable o Port 02 enable 0 Port 03 enable 0 04 enable 0 Port 05 enable 0 Port 06 enable 0 Port 07 enable 0 Port 08 enable P2P Edge auto wj true auto y true auto gt true jm auto x true m auto x true E auto x true m auto y true auto true 128 128 128 128 128 128 128 128 TI EQUITEL Technical Manual N965 64 i 6 18 2 RSTP Information This web page provides the port and switch information about RSTP RSTP RSTP Information In formatio n N A Root Priority N A Root Port N A Root Path Cost N A Max Age Time N A Hello Time N A Forward Delay Time N A Port Inform rma tion Port Path Cost Port Priority OperP2P OperEdge STP Neighbor State Role RSTP System Configuration interface EQUITEL Technical Manual N965 65 6 19 Pro Ring Il S Pro Ring Ils is a new Ring mechanism for Equitel Industrial Switches in which it protects the network by flexible topology than ever Ils works as a Single Ring and Multiple Ring to recover the broken ring in less than 20 ms for up to 50 switch nodes B Root Switch To enable the X Ring function first you must set your switch as Enable or Backup Enable m
35. 8 800pps for Fast Ethernet port 1 488 000pps for Gigabit Fiber Ethernet port Packet Buffer 1Mbits MAC Address 8K MAC address table EQUITEL Technical Manual N965 Flash ROM 4Mbytes DRAM 32Mbytes 10 100TX 8 x ports RJ 45 with Auto MDI MDI X function 10 100 1000T SFP Combo port 2 x RJ 45 2 x 100 1000 SFP socket with DDM RS 232 connector RJ 45 type 10Base T 2 pair UTP STP Cat 3 4 5 5E cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 5E cable EIA TIA 568 100 ohm 100m 1000Base TX 2 pair UTP STP Cat 5 5E cable EIA TIA 568 100 ohm 100m Connector Network Cable Distance Multi mode 0 to 5 km 1300 nm 50 125 800 MHz km 0 to 4 km 1300 nm 62 5 125 500 MHz km Single mode 0 to 40 km 1310 nm 9 125 3 5 PS nm km 0 to 80 km 1550 nm 9 125 19 PS nm km Optical Fiber Min TX Output Multi mode 20 dBm Single mode 0 to 40 km 5 dBm 0 to 80 km 5 dBm Max TX Output Multi mode 14 dBm Single mode 0 to 40 km 0 dBm 0 to 80 km 0 dBm Sensitivity 36 to 32 dBm Single mode 34 to 30 dBm Multi mode Protocol CSMA CD L TI EQUITEL Technical Manual N965 Jan 2013 Ed 2 01 Per unit Power Green Power 1 Green Power 2 Green Fault Red Master Green FWD Green 8 port 10 100 Link Activity Green Full duplex Collision Amber SFP port LNK ACT Green 1000T LNK ACT Green
36. 965 24 Chapter 5 Console Management 5 1 Connecting to the Console Port The supplied cable which one end is RS 232 connector and the other end is RJ 45 connector Attach the end of RS 232 connector to PC or terminal and the other end of RJ 45 connector to the console port of the switch The connected terminal or PC must support the terminal emulation program TSN JPE To the console port of To or Terminal the Industrial Switch DB 9 pin Female 5 2 Pin Assignment DB9 Connector RJ 45 Connector NC 1 OrangeMWhite 2 2 Orange 3 3 Green White NC 4 Blue 5 5 Blue White NC Green 6 NC 7 Brown White 8 Brown EQUITEL Technical Manual N965 25 Jan 2013 Ed 2 01 CQUITEL 5 3 Login in the Console Interface When the connection between Switch and PC is ready turn on the PC and run a terminal emulation program or Hyper Terminal and configure its communication parameters to match the following default characteristics of the console port Baud Rate 9600 bps Data Bits 8 Parity none Stop Bit 1 Flow control None L271 COM2 Properties Port Settings Bits per second CENE Data bits fp M Parity None mj Stop bits HM Elow control oe mj Advanced Restore Defaults The settings of communication parameters Having finished the parameter s
37. Group ID Trunk Member Trunk 1 Trunk 2 EQUITEL Technical Manual N965 Type Static Static Static Static Static Jan 2013 Ed 2 01 62 6 18 Spanning Tree The Rapid Spanning Tree Protocol RSTP is an evolution of the Spanning Tree Protocol and provides for faster spanning tree convergence after a topology change The system also supports STP and the system will auto detect the connected device that is running STP or RSTP protocol 6 18 1 RSTP Setting This web page provides the port configuration interface for RSTP You can assign higher or lower priority to each port Rapid spanning tree will have the port with the higher priority in forwarding state and block other ports to make certain that there is no loop in the LAN gt RSTP mode The user must enable the RSTP function first before configuring the related parameters gt Priority The switch with the lowest value has the highest priority and is selected as the root If the value is changed the user must reboot the switch The value must be a multiple of 4096 according to the protocol standard rule gt Max Age The number of seconds a switch waits without receiving Spanning tree Protocol configuration messages before attempting a reconfiguration Enter a value between 6 through 40 gt Hello Time The time that controls the switch to send out the BPDU packet to check RSTP current status Enter a value between 1 through 10 gt Forward Delay Time The number
38. N965 Managed industrial switch 8 10 100TX 2 10 100 1000T Dual Speed SFP Combo Managed Industrial Switch RESET PWR RM PWR1 PWR2 FAULT Console kL 9600 N 8 1 CQUITEL Jan 2013 Ed 2 01 About this manual This document is the technical reference of the model N965 an 8 10 100TX 2 10 100 1000T SFP modules combo Managed Industrial Switch Equipos De Telecomunicaci n Optoelectr nicos S A Zaragoza Spain Jan 2013 Ed 2 01 El Equipos de Telecomunicaci n Optoelectr nicos S A Pol gono de Malpica c F oeste G Quejido nave 74 50057 Zaragoza SPAIN Tel 34 976 570 353 Fax 34 976 571 383 E mail mail equitel es WwwW equitel es The information included in this manual cannot be copied or reproduced in any way without the previous written authorisation of Equipos de Telecomunicaci n Optoelectr nicos S A EQUITEL Technical Manual N965 Content Chapter 1 1 1 1 2 1 3 Chapter 2 2 1 2 2 2 3 2 4 Chapter 3 3 1 3 2 3 3 3 4 3 5 3 6 Chapter 4 4 1 Chapter 5 53 5 2 5 3 5 4 Jan 2013 Ed 2 01 e Lo uu lu ai 1 Hardware Features 1 Software Features 4 Package 7 Hardware Description 8 Physical Dimension 8 Front Panel aas ueecuci
39. _ QoS Policy C Use an 8 4 2 1 weighted fair queuing scheme Use a strict priority scheme 6 25 2 Port Priority Configure the priority level for each port With the drop down selection item of Priority Type above being selected as Port based this control item will then be available to set the queuing policy for each port W Port x Each port has 4 priority levels High Middle Low and Lowest to be chosen m Click Apply to have the configuration take effect EQUITEL Technical Manual N965 80 D QoS Port Prioritys Port Setting PortMo Priority Port 01 Lowest v Port 02 Lowest v Port 03 Lowest v Port 04 Lowest v Port 05 Lowest Port 06 Lowest Port 07 Lowest v Port 08 Lowest v Gi Lowest v G2 Lowest 6 25 3COS Mapping to Queue Set up the COS priority level With the drop down selection item of Priority Type above being selected as COS only COS first this control item will then be available to set the queuing policy for each port B COS priority Set up the COS priority level 0 7 High Middle Low Lowest W Click Apply EQUITEL Technical Manual N965 81 exe Qos CoS Mapping to Queue Jan 2013 Ed 2 01 COS Priority Setting COS Priority Lowest ll i Dow 2 5 i cw H 4 E 5 6 7 COS Port Default Setting Port No COS Port 01 gt Port o2 gt Port o3 o v
40. able switch show syslog no syslog G Disable systemlog switch gt enable functon switch configure switch config no syslog smtp enable G Enable SMTP function switch gt enable switch configure switch config smtp enable smtp serverip G Configure SMTP switch gt enable IP address server IP switch configure switch config smtp serverip 192 168 1 5 smtp sender G Configure sender of switch enable sendername mail switch configure switch config smtp sender test01 smtp subject subject G Configure subject of switch gt enable EQUITEL Technical Manual N965 130 Jan 2013 Ed 2 01 mail switch configure switch config smtp subject alarm smtp authentication Enable SMTP switch gt enable authentication switch configure switch config smtp authentication smtp account Configure switch gt enable account authentication account switch configure switch config smtp account John smtp password password Configure authentication password switch gt enable switch configure switch config smtp password 1234 smtp rcptemail Index Email address Configure Rcpt e mail Address switch gt enable switch configure switch config smtp rcptemail 1 Alert test com show smtp Show the information switch gt enable of SMTP switch show smtp no smtp Disable SMTP switch gt enable function switch configure switch config no smtp event device restart Syslog SMTP Both Set device restart
41. able G Enable IP security switch gt enable function switch configure switch config security enable security http G Enable IP security of switch enable HTTP server switch configure switch config security http security telnet G Enable IP security of switch gt enable telnet server switch configure switch config security telnet security snmp G Enable IP security of switch enable SNMP server switch configure switch config security snmp security ip G Set the IP security list switch gt enable Index 1 10 IP switch configure Address switch config security ip 1 192 168 1 55 show security Show the information switch gt enable of IP security switch show security no security G Disable IP security switch gt enable function switch configure switch config no security no security http G Disable IP security switch gt enable HTTP server switch configure switch config no security http EQUITEL Technical Manual N965 125 CQUITEL Jan 2013 Ed 2 01 no security telnet G Disable IP security of switch gt enable telnet server switch configure switch config no security telnet no security snmp G Disable IP security switch gt enable SNMP server switch configure switch config no security snmp Port Security Commands Set Netstar Commands Level Description Example mac address table static hwaddr HW Addr Configure MAC address entry of
42. alue RXPWR Display the received power of the SFP default threshold and present value Syslog SMTP The port will send an e mail or log on local to administrator when detecting the exceptional value Diagnostics DDM J Event Alarm syslog smtp Monitor PortNo Type Temperature Vcc TX Bias TX Power RX Power EQUITEL Technical Manual N965 97 Troubles shooting Verify that is using the right power cord adapter DC 24 48V please don t use the power adapter with DC output higher than 48V or it may damage this device Select the proper UTP STP cable to construct the user network Use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections that depend on the connector type the switch equipped 1000 Category 3 4 or 5 cable for 10Mbps connections 1000 Category 5 cable for 100Mbps connections or 100 Category 5e above cable for 1000Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored through panel indicators which describe common problems the user may encounter and where the user can find possible solutions If the power indicator does not light on when the power cord is plugged in you may have a problem with power cord Then check for loose power connections power losses or surges at power outlet If you
43. ck the un authorized client in this function 6 26 1 IP Source Guard Configuration IP Source Guard function allows the user to assign 10 specific IP addresses that have permission to manage the switch through the http and telnet services for the securing switch management The purpose of giving the limited IP addresses permission is to allow only the authorized personnel device can do the management task on the switch IP Security Mode Having set this selection item in the Enable mode the Enable HTTP Server Enable Telnet Server checkboxes and the ten security IP column fields will then be available If not those items will appear in grey m Enable HTTP Server Having ticked this checkbox the devices whose IP addresses match any one of the ten IP addresses in the Security IP1 IP10 table will be given the permission to access this switch via HTTP service m Enable Telnet Server Having ticked this checkbox the devices whose IP addresses match any one of the ten IP addresses in the Security IP1 IP10 table will be given the permission to access this switch via telnet service m Enable SNMP Management Having ticked this checkbox the devices whose IP addresses match any one of the ten IP addresses in the Security IP1 IP10 table will be given the permission to access this switch via SNMP service IP Source Guard Configuration Configuration Static Table Settings IP Security Mode Disable Enable WEB Management
44. ckbox the mail account password and confirm password column fields will then show up Configure the email account and password for authentication when this switch logs in to the SMTP server B Account Set up the email account e g johnadmin to receive the email alert It must be an existing email account on the mail server Password Type in the password for the email account Confirm Password Reconfirm the password Rcpt e mail Address 1 6 You can also fill each of the column fields with up to 6 e mail accounts to receive the email alert m Click Apply to have the configuration take effect EQUITEL Technical Manual N965 45 exi System Alert SMTP Jan 2013 Ed 2 01 SMTP Setting E mail Alert Disable gt SMTP Server Address 8220 Sender E mail Address administrator Mail Subject hutomatedEmallAlert l Authentication Recipient E mail Setting i E mail Address 1 III E mail Address 2 ap E mail Address 3 p E mail Address 4 J E mail Address 5 E mail Address 6 8 2 System Alert Event Having ticked the Syslog SMTP checkboxes the event log email alert will be sent to the system log server and the SMTP server respectively Also Port event log alert link up link down and both can be sent to the system log server SMTP server respectively by setting the trigger condition System event selection There are 3 event types Device Col
45. correct file name for restoring Click Restore Import Config From TFTP Server i TFTP Server IP Address 192 168 16 30 Restore File Name data bin Restore Import From Local f Restore You can back up the current configuration from flash ROM to the TFTP server for the purpose of recovering the configuration later It helps you to avoid wasting time on configuring the settings by backing up the configuration W TFTP Server IP Address Type in the TFTP server IP Backup File Name Type in the file name W Click Backup EQUITEL Technical Manual N965 95 exe Export Import Jan 2013 Ed 2 01 Ewport Config To TFTP Servs TFTP Server IP Address 192 168 16 30 Backup File Name data bin Export To Local 6 27 6 Diagnostics 6 27 6 1 Ping You can ping other network device in this function Diagnostics Ping Ar g Utility IP Address _Active Help 6 27 6 2 DDM Port No Specify the SFP port and show the SFP module information Temperature Display the internal temperature of the SFP default threshold and present value EQUITEL Technical Manual N965 96 D gt Vcc Display the supply voltage of the SFP default threshold and present value gt Tx Bias Display the Bias current the SFP default threshold and present value gt TX PWR Display the transmission power of the SFP default threshold and present v
46. d 10 8021x misc txperiod Seconds Use the 802 1x misc TX period global configuration command to set the TX period switch gt enable switch configure switch config 8021x misc txperiod 5 8021x misc supptimeout Use the 802 1x misc switch gt enable Seconds supp timeout global switch configure configuration switch config 8021x misc command to set the supptimeout 20 supplicant timeout 8021x misc Use the 802 1x misc switch enable servertimeout Seconds server timeout global configuration command to set the server timeout switch configure switch config 8021x misc servertimeout 20 8021x misc maxrequest number Use the 802 1x misc max request global configuration command to set the MAX requests switch gt enable switch configure switch config 8021x misc maxrequest 3 EQUITEL Technical Manual N965 128 CQUITGL Jan 2013 Ed 2 01 8021x misc G Use the 802 1x misc switch enable reauthperiod Seconds reauth period global _ switch configure configuration switch config 8021x misc command to set the reauthperiod 3000 reauth period 8021x portstate Use the 802 1x port switch 2enable disable reject accept state interface switch configure authorize configuration switch config interface command to set the fastethernet state of the selected _ switch config if 8021x portstate port authorize s
47. d Start Authentication Failure and X ring Topology Change The checkboxes are not available for ticking unless the Syslog Client Mode on the Syslog Configuration tab and the E mail Alert on the SMTP Configuration tab are enabled first System Restart When the device executes cold start action the system will issue the event log email alert to the system log SMTP server respectively Power Status When the power consumption about PoE was unstable he EQUITEL Technical Manual N965 46 D EQUITEL Jan 2013 Ed 2 01 System will issue the event log email alert to the system log SMTP server respectively SNMP Authentication Failure When the SNMP authentication fails the system will issue the event log email alert to the system log SMTP server respectively System Alert Event System Event Event Syslog SMTP System Restart Disable Power Status SNMP Authentication Failure Disable Event Configuration interface EQUITEL Technical Manual N965 47 DHCP Server i DHCP is the abbreviation of Dynamic Host Configuration Protocol that is a protocol for assigning dynamic IP addresses to devices on a network With dynamic addressing a device can have a different IP address every time it connects to the network In some systems the device s IP address can even change while it is still connected DHCP also supports a mix of static and dynamic IP addresses Dynamic addressing simplifie
48. e switch gt enable group ID switch vlan database switch vlan no vlan 2 IEEE 802 1Q VLAN EQUITEL Technical Manual N965 118 CQUITEL Jan 2013 Ed 2 01 vlan 8021q mnt vid VID Configure management VID 0 is disabled switch gt enable switch vlan database switch vlan vlan 8021q mnt vid 22 vlan 8021q name GroupName vid VID Change the name of VLAN group if the group didn t exist this command can t be applied switch gt enable switch vlan database switch vlan zivlan 80214 name test vid 22 vlan 8021q port PortNumber access link untag UntaggedVID Assign a access link for VLAN by port if the port belong to a trunk group this command can t be applied switch gt enable switch vlan database switch vlan vlan 80214 port access link untag 22 vlan 8021q port PortNumber trunk link tag TaggedVID List Assign a trunk link for VLAN by port if the port belong to a trunk group this command can t be applied switch gt enable switch vlan database switch vlan vlan 80214 port trunk link tag 2 3 6 99 or switch vlan vlan 80214 port trunk link tag 3 20 vlan 8021q port PortNumber hybrid link untag UntaggedVID tag TaggedVID List Assign a hybrid link for VLAN by port if the port belong to a trunk group this command can t be applied switch gt enable switch vlan database switch vlan vlan 80214 port
49. eans this switch will play the role of root switch Backup means this switch will take over the role of root switch when the original root switch fail setting set the port which you want to build the Ring topology usually set as G1 and G2 With some advance redundancy solution like Couple ring and Dual homing if you are confused about which port was needed to enable just select all the port which was responsible for uplink And then click Apply to have the configuration take effect EQUITEL Technical Manual N965 66 Jan 2013 Ed 2 01 Port No Active State Port o1 INACTIVE Port 02 Part 03 04 05 06 07 08 09 Port 10 INACTIVE INACTIVE INACTIVE INACTIVE INACTIVE INACTIVE INACTIVE INACTIVE INACTIVE CE COLE CHICH CHICH LT ICI RSTP Port Configuration interface EQUITEL Technical Manual N965 67 6 20 Multicast Support The Internet Group Management Protocol IGMP is an internal protocol of the Internet Protocol IP suite IP manages multicast traffic by using switches routers and hosts that support IGMP Enabling IGMP allows the ports to detect IGMP queries report packets and manage IP multicast traffic through the switch IGMP have three fundamental types of message shown as follows Message Description A message sent from the querier IGMP router or switch Query asking for a response from each host belonging
50. echnical Manual N965 21 Jan 2013 Ed 2 01 EQUITEL Technical Manual N965 22 2013 2 01 Chapter 4 Network Application This chapter provides some sample applications to help user to have more actual idea of industrial switch function application A sample application of the industrial switch is as below Data collect server Enterprise Switch Industrial Switch Field Management Distribute I O control system Programmable logic controller Field Automatic device Serial Device Server Field Automatic device Field Automatic device EQUITEL Technical Manual N965 23 4 1 Pro Ring2s Application Pro Ring Il is a new Ring mechanism for Equitel Industrial Switches in which it eliminates the need to pre set the Master switch in old Pro Ring and yet to protect the network by much secure topologies than ever Pro Ring Il works as a Ring Chain to reduce the risk of master switch linking down whereas the setup becomes much easier Pro Ring Ill can be backward compatible with old Pro Ring by down grading the Ring scheme to old one Data collect server Human Management Interface Enterprise Switch Field Management Pro Ring2s Group Industrial Switch Backup Path Programmable logic controller Distribute I O control system Serial Device Server ield Automatic device Field Automatic device Field Automatic device EQUITEL Technical Manual N
51. et address of switch switch configure EQUITEL Technical Manual N965 105 CQUITEL Jan 2013 Ed 2 01 mask Gateway switch config ip address 192 168 1 1 255 255 255 0 192 168 1 254 ip dhcp G Enable DHCP client switch enable function of switch switch configure switch config ip dhcp show ip P Show IP information of switch gt enable switch switch show ip no ip dhcp G Disable DHCP client switch gt enable function of switch switch configure switch config no ip dhcp SNTP Commands Set Netstar Commands Level Description Example sntp enable G Enable SNTP function switch gt enable switch configure switch config sntp enable sntp ip G Set SNTP server IP if switch gt enable IP SNTP function is switch configure inactive this switch config sntp ip command can t be 192 168 16 1 applied sntp timezone G Set timezone index switch enable Timezone Format use show sntp switch configure 1 63 timzezone command _ switch config sntp timezone 22 to get more information of index number sntp daylight G Enable daylight saving switch gt enable time if SNTP function switch configure is inactive this switch config sntp daylight EQUITEL Technical Manual N965 106 CQUITEL Jan 2013 Ed 2 01 command can t be applied sntp daylight period G Set period of daylight switch gt enable Start time E
52. ettings click OK When the blank screen shows up press Enter key to have the login prompt appears Key in root default value for both User name and Password use Enter key to switch then press Enter and the Main Menu of console management appears Please see below figure for login screen 26 EQUITEL Technical Manual N965 Jan 2013 Ed 2 01 User Name root Password Console login interface EQUITEL Technical Manual N965 27 Jan 2013 Ed 2 01 CQUITEL 5 4 CLI Management The system supports the console management CLI command After you log in on to the system you will see a command prompt To enter CLI management interface type in enable command switch gt e switch CLI command interface EQUITEL Technical Manual N965 28 IT gi Jan 2013 Ed 2 01 Chapter 6 Web Based Management This section introduces the configuration and functions of the Web Based management 6 1 About Web based Management There is an embedded HTML web site residing in flash memory on CPU board of the switch which offers advanced management features and allows users to manage the switch from anywhere on the network through a standard browser such as Microsoft Internet Explorer The Web Based Management supports Internet Explorer 6 0 or later version And it is applied for Java Applets for reducing network bandwidth consumption enhance access speed and present an easy viewing screen 6 2 Preparing for
53. evel of performance to a data flow QoS guarantees are important if the network capacity is insufficient especially for real time streaming multimedia applications such as voice over IP or Video Teleconferencing since these often require fixed bit rate and are delay sensitive and in networks where the capacity is a limited resource for example in cellular data communication In the absence of network congestion QoS mechanisms are not required 6 25 1 Global Settings Here you can choose to use an 8 4 2 1 queuing scheme or a strict priority scheme or select the priority type to configure QoS policy m Qos Policy Select the QoS policy rule Using the 8 4 2 1 weight fair queue scheme The switch will follow 8 4 2 1 rate to process priority queue from High to lowest queue For example while the system processing 1 frame of the lowest queue 2 frames of the low queue 4 frames of the middle queue and 8 frames of the high queue will be processed at the same time in accordance with the 8 4 2 1 policy rule gt Usea strict priority scheme Always the higher queue will be processed first except the higher queue is empty Priority Type There are 5 priority type selections available Port based TOS only COS only TOS first and COS first Disable means no priority type is selected m Click Apply to have the configuration take effect EQUITEL Technical Manual N965 79 Le Qos Global Settings Disable
54. fastEthernet 2 no accounting switch config if no accounting Port Monitoring Commands Set Netstar Commands Level Description Example monitor destination Configure destination switch gt enable port of monitor switch configure function switch config interface fastEthernet 2 switch config if monitor RX TX Both destination rx Configure destination switch gt enable switch configure switch config interface monitor source RX TX Both port of monitor function fastEthernet 2 switch config if monitor source rx show monitor P Show port monitor switch gt enable information switch show monitor Show port monitor switch gt enable information switch configure switch config interface show monitor Disable source port of monitor function fastEthernet 2 switch config if show monitor switch gt enable switch configure switch config interface no monitor fastEthernet 2 switch config if no monitor 134 EQUITEL Technical Manual N965 CQUITEL System Event Log Commands Set Jan 2013 Ed 2 01 Netstar Commands Level Description Example show syslog P Show SYSLOG configuration and log switch gt enable switch show syslog table Ping Commands Set Netstar Commands Level Description Example ping E Ping function switch gt ping 192 168 16 1 ip SFP Monitor Commands Set Netstar Commands Level Descrip
55. filled in the Tagged VID column field Please insert a comma between two VIDs Note A trunk port doesn t insert tag into an untagged frame and therefore the EQUITEL Technical Manual N965 76 untagged VID column field is not available It s not necessary to type 1 in the tagged VID The trunk port will forward the frames of VLAN 1 The trunk port has to be connected to a trunk hybrid port of the other switch Both the tagged VID of the two ports have to be the same 3 Hybrid Link A segment which consists of Access and Trunk links The hybrid port has both the features of access and trunk ports A hybrid port has a PVID belonging to a particular VLAN and it also forwards the specified tagged frames for the purpose of VLAN communication across switches 4 QinQ Double Tag VLAN configuration Double Tag VLAN is another mechanism employed in a Metro LAN in which it can save IP v4 address by residing groups of sub VLANs customer port in a VLAN Host and utilizing the default gateway IP address of Double Tag VLAN sharing the same IP subnet mask Double Tag VLAN in L2 provides enhances security between customer each home by dis communication between the sub VLANs even they are located in the same LAN and have the same IP subnet mask Better yet the configuration is simple than assigning each VLAN as per port based VLAN to customer each home Note 1 It s not necessary to type 1 in the tagged VID The hybrid port wil
56. hardware spec port cabling information and wiring installation 2 1 Physical Dimension 74mm x 115mm x 152mm W x D x H 2 2 Front Panel Front Panel of the industrial switch EQUITEL Technical Manual N965 D 2 3 Bottom View The bottom panel of the Industrial Managed Industrial Switch has one terminal block connector of two DC power inputs and one fault alarm PWR2 FAULT PWR1 Box j V2 V2 1 19 DC48V Bottom Panel of the industrial switch EQUITEL Technical Manual N965 2 4 LED Indicators The diagnostic LEDs that provide real time information of system and optional status are located on the front panel of the industrial switch The following table provides the description of the LED status and their meanings for the switch LED Meaning The switch unit is power on PWR No power The industrial switch is the master of Pro n Ring2s group R M Green Of The industrial switch is not a ring master in Pro Ring2s group pwr PWR2 FAULT Green Emi The port is transmitting or receiving packets inkin Upper LED 3 from the TX device i P9 P10 RJ 45 Green Lower LED EQUITEL Technical Manual N965 On The SFP port is linking i Link Active I P9 P10 Green Blinks from the TX device o p 3 No device attached A network device is detected The port is transm
57. hernet connection 6 Insert one side of RJ 45 cable category 5 into the Industrial switch Ethernet port NOTE 7 EQUITEL RJ 45 port and another side of RJ 45 cable category 5 to the network device s Ethernet port RJ 45 port ex Switch PC or Server The UTP port RJ 45 LED on the Industrial switch will light up when the cable is connected with the network device Please refer to the LED Indicators section for LED light indication Make sure that the connected network devices support MDI MDI X If it does not support use the crossover category 5 cable When all connections are set and LED lights all show in normal the installation is complete Technical Manual N965 12 Jan 2013 Ed 2 01 CQUITEL 3 2 DIN Rail Mounting The DIN Rail is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following pictures to screw the DIN Rail on the switch Follow the steps below to hang the industrial switch Rear Side DIN Rail EQUITEL Technical Manual N965 Jan 2013 Ed 2 01 First insert the top of DIN Rail into the track 2 Then lightly push the DIN Rail into the track Check if the DIN Rail is tightened on the track or not B 4 To remove the industrial switch from the track reverse above steps 14 EQUITEL Technical Manual N965 Jan 2013 Ed 2 01 3 3 Wall Mount Plate Mounting Follow the ste
58. his function Port Security MAC Address I PortNo Port oi gt Add Delete Help MAC Address EQUITEL Technical Manual N965 92 CQUITEL 6 27 Maintenance i Jan 2013 Ed 2 01 6 27 1 Save Configuration Save the current setting of switch Save Configuration 6 27 2 Restart Device Make the switch warm start Restart Device Please click Reboot button to restart switch device 6 27 3 Factory Defaults Reset switch to default configuration Click Reset to reset all configurations to the default value Factory Defaults Keep current IP address setting Keep current username amp password EQUITEL Technical Manual N965 93 6 27 4 Firmware Upgrade TFTP Server IP Address Type in your TFTP server IP Firmware File Name Type in the name of the firmware image file to be updated Click Upgrade i Firmware Upgrade TFTP Server IP 192 168 16 30 Firmware File Name image bin You can also browser the firmware on your hard drive by web update Firmware Upgrade EQUITEL Technical Manual N965 94 D 6 27 5 Export Import You can restore a previous backup configuration from the TFTP server to recover the settings Before doing that you must locate the image file on the TFTP server first and the switch will download back the flash image TFTP Server IP Address Type in the TFTP server IP m Restore File Name Type in the
59. how 8021x P Displays a summary of switch gt enable the 802 1x properties switch show 8021x and also the port sates no 8021x G Disable 802 1x switch gt enable function switch configure switch config no 8021x Fault Alarm Commands Set Netstar Commands Level Description Example fault relay power G Configure Relay Alarm switch gt enable number for Power Failure switch configure enable disable switch config fault relay power 1 enable fault relay Configure Relay Alarm switch gt enable enable disable for Port Link switch configure Down Broken switch config interface fastEthernet 1 switch config if fault relay enable show fault relay P Show Fault Relay switch gt enable EQUITEL Technical Manual N965 129 CQUITEL Jan 2013 Ed 2 01 Alarm setting switch show fault relay no fault relay Disable Fault Relay Alarm function switch gt enable switch configure switch config no fault relay System Warning Co mmands Set Netstar Commands Level Description Example systemlog mode client server both G Specified the log mode switch gt enable switch configure switch config syslog mode both systemlog ip G Set System log server switch gt enable IP address IP address switch configure switch config syslog ip 192 168 1 100 show syslog P Show SYSLOG switch gt enable configuration and log switch configure t
60. how console switch gt enable information switch show terminal system name G Configure system switch gt enable System Name name switch configure EQUITEL Technical Manual N965 104 CQUITEL Jan 2013 Ed 2 01 switch config system name xxx system location G Set switch system switch gt enable System Location location string switch configure switch config system location XXX system description G Set switch system switch gt enable System Description description string switch configure switch config system description xxx system contact G Set switch system switch gt enable System Contact contact window string switch configure switch config system contact XXX show system info E Show system switch gt show system info information Admin Password Commands Set Netstar Commands Level Description Example admin username Username G Changes a login username maximum 10 words switch gt enable switch configure switch config admin username XXXXXX admin password G Specifies a password switch gt enable Password maximum 10 words j switch configure switch config admin password XXXXXX show admin Show administrator switch gt enable information switch show admin IP Setting Commands Set Netstar Commands Level Description Example ip address G Configure the IP switch gt enable lp address Subn
61. ication and capability on the LAN IEEE802 1d spanning tree IEEE802 1w rapid spanning tree Supports Pro Ring2s Provides redundant backup feature and the recovery time below 20ms The quality of service determined by port Tag and IPv4 Type of service IPv4 Different Service Supports IEEE802 1p class of service per port provides 4 priority queues Supports 100 entries of MAC address for static MAC and another 100 for MAC filter Supports 3 mirroring types RX TX and Both packet EQUITEL Technical Manual N965 PUN Full gi m Jan 2013 Ed 2 01 UE Supports IGMP snooping v1 v2 256 multicast groups and IGMP query Supports 10 IP addresses that have permission to access IP Security the switch management and to prevent unauthorized intruder Login Security Supports IEEE802 1X Authentication RADIUS The egress rate control supports all of packet type and the limit rates are 100K 102400Kbps 10 100 100K 256000Kbps 1000 Ingress filter packet type combination rules are Bandwidth Control Broadcast Multicast Unknown Unicast packet Broadcast Multicast packet Broadcast packet only and all of packet The packet filter rate can be set from 100K 102400Kbps 10 100 100K 256000Kbps 1000 Supports Flow Control for Full duplex and Back Pressure Flow Control for Half duplex System Log Supports System log record and remote system log server Supports SMTP Server and 6 e mail accounts fo
62. ig interface fastethernet 3 switch config if no event smtp EQUITEL Technical Manual N965 132 CQUITEL Mac Address Table Commands Set Jan 2013 Ed 2 01 Netstar Commands Level Description Example show mac address table Show MAC address switch gt enable table switch configure switch config interface fastethernet 2 switch config if show mac address table show mac address table P Show MAC address switch gt enable all table all switch show mac address table all no mac address table G Remove dynamic switch gt enable entry of MAC address table switch configure switch config no mac address table agingtime seconds G Configure mac switch gt enable 0 3825 steps 15 address table aging _ switch configure time switch config agingtime 30 auto flush G Auto flush mac switch gt enable enable disable address table when ports link down switch configure switch config auto flush enable Port Statistics Commands Set Netstar Commands Level Description Example show interface accounting show interface statistic counter switch gt enable switch configure switch config interface fastEthernet 2 switch config if show interface accounting EQUITEL Technical Manual N965 133 CQUITEL Clear interface accounting information Jan 2013 Ed 2 01 switch gt enable switch configure switch config interface
63. in the specific multicast groups With multicast filtering network devices only forward multicast traffic to the ports that are connected to the registered end stations M Address Assign a multicast group IP address in the range of 224 0 0 0 239 255 255 255 B Member Ports Tick the check box beside the port number to include them as the member ports in the specific multicast group IP address EQUITEL Technical Manual N965 69 m Click Add to append a new filter of multicast to the field or select the filter in the i field and click Delete to remove it Multicast Support Static Filtering IP Address Port o1 Port o2 Port 03 Port 04 Member Ports port 05 Port o6 Port 07 Port os l 5762 ERR IP Address Member Ports EQUITEL Technical Manual N965 70 LLDP EE 6 2 Link Layer Discovery Protocol LLDP is defined in the IEEE 802 1AB it is an emerging standard which provides a solution for the configuration issues caused by expanding LANs LLDP specifically defines a standard method for Ethernet network devices such as switches routers and wireless LAN access points to advertise information about themselves to other nodes on the network and store the information they discover LLDP runs on all 802 media The protocol runs over the data link layer only allowing two systems running different network layer protocols to learn about each other 6 21 1 LLDP Co
64. interfaces switch configure switch config no prorstp show prorstp P Show PRO RING IIS switch enable configuration switch show prorstp RSTP Commands Set Netstar Commands Level Description Example rstp enable G Enable RSTP switch gt enable switch configure switch config rstp enable rstp priority 0 61440 G Configure RSTP switch gt enable bridge priority switch configure parameter switch config rstp priority 4096 rstp max age 6 40 G Configure RSTP max switch gt enable age parameter switch configure switch config rstp max age 6 rstp hello time 1 10 G Configure RSTP hello switch gt enable time parameter switch configure switch config rstp hello time 1 rstp forward time 4 30 Configure RSTP switch gt enable forward time parameter switch configure switch config rstp forward time 4 EQUITEL Technical Manual N965 116 rstp path cost Path cost on this switch gt enable 0 auto 1 200000000 interface switch configure switch config interface fastEthernet 2 switch config if rstp path cost 20 rstp port priority Port priority on this switch gt enable 0 240 interface switch configure switch config interface fastEthernet 2 switch config if rstp port priority 16 rstp admin p2p Admin P2P on this switch gt enable Auto True False interface switch configure switch config interface fastEthernet 2 switch config if rstp admin p2p false rstp admin edge Admin Edge
65. itch configure switch config no Backup amp Restore Comm ands Set Netstar Commands Level Description Defaults Example tftp server IP backup G file name Save configuration to TFTP and need to specify the IP of TFTP server and the file name of image switch gt enable switch configure switch config tftp 192 168 16 120 backup 123 bin tftp server IP restore file name Get configuration from TFTP server and need to specify the IP of TFTP server and the file name of image switch gt enable switch configure switch config tftp 192 168 16 120 restore 123 bin Upgrade Firmware Commands Set Netstar Commands Level Description Defaults Example tftp server IP upgrade G file name Upgrade firmware by TFTP and need to specify the IP of TFTP server and the file name of image switch gt enable switch configure switch config tftp 192 168 16 120 upgrade image bin EQUITEL Technical Manual N965 108 CQuITEL DHCP Server Commands Set Jan 2013 Ed 2 01 Netstar Commands Level Description Example dhcpserver enable G Enable DHCP Server switch gt enable switch configure switch config dhcpserver enable dhcpserver lowip G Configure low IP switch gt enable Low IP address for IP pool switch configure switch config dhcpserver lowip 192 168 1 100 dhcpserver highip G Configure
66. itting or receiving packets from the TX device No device attached P1 P8 The port is operating in full duplex mode The port is transmitting or receiving packets Amber The port is in half duplex mode or no device Off is attached A powered device is connected utilizing Green Power over Ethernet on the port or No device is connected or power forwarding FWD P1 P8 Green fails EQUITEL Technical Manual N965 Chapter 3 Hardware Installation In this paragraph we will describe how to install the Pro Ring2s Managed Industrial Switch and the installation points attended to it 3 1 Installation Steps Unpack the Industrial switch Check if the DIN Rail is screwed on the Industrial switch or not If the DIN Rail is not screwed on the Industrial switch please refer to DIN Rail Mounting section for DIN Rail installation If users want to wall mount the Industrial switch please refer to Wall Mount Plate Mounting section for wall mount plate installation 3 To hang the Industrial switch on the DIN Rail track or wall 4 Power on the Industrial switch Please refer to the Wiring the Power Inputs section for knowing the information about how to wire the power The power LED on the Industrial switch will light up Please refer to the LED Indicators section for indication of LED lights 5 Prepare the twisted pair straight through Category 5 cable for Et
67. kbps or to 256000 kbps for giga ports and zero means no limit switch config interface fastEthernet 2 switch config if ratelimit out 160 EQUITEL Technical Manual N965 113 CQUITEL Jan 2013 Ed 2 01 show ratelimit Show interfaces bandwidth control switch gt enable switch configure switch config interface fastEthernet 2 switch config if show ratelimit Trunk Commands Set Netstar Commands Level Description Example aggregator priority G Set port group system switch gt enable 1 65535 priority switch configure switch config aggregator priority 22 aggregator group G Assign a trunk group switch enable GroupID Port list with LACP active switch configure lacp GroupID 1 3 switch config aggregator group workp Port list Member port 1 1 4 lacp workp 2 Workport list This parameter or could be a port switch config aggregator group range ex 1 4 or a port 2 1 4 3 lacp workp 3 list separate by a comma ex 2 3 6 Workport The amount of work ports this value could not be less than zero or be large than the amount of member ports aggregator activityport G Set activity port switch gt enable Group ID Port Numbers switch configure switch config aggregator activityport 1 2 EQUITEL Technical Manual N965 114 CQUITEL Jan 2013 Ed 2 01 aggregator group G Assign a static trunk switch enable GroupID Port list g
68. l N965 Jan 2013 Ed 2 01 JEQUITEL Port Security Commands Set MAC Blacklist Commands Set 802 1x Commands Set 127 Fault Alarm Commands 129 130 System Warning Commands Set Mac Address Table Commands Set 134 Port Statistics Commands Set Port Monitoring Commands Set System Event Log Commands Set Ping Commands Set SFP Monitor Commands Set Loading Average Commands Set Save Configuration Commands Set Factory Default Commands Set System Reboot Commands Set Logout Commands Set EQUITEL Technical Manual N965 Jan 2013 Ed 2 01 CQUITEL FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is
69. l forward the frames of VLAN 1 2 The trunk port has to be connected to a trunk hybrid port of the other switch Both the tagged VID of the two ports have to be the same e Untagged VID This column field is available when Link Type is set as Access Link and Hybrid Link Assign a number in the range between 1 an 4094 Tagged VID This column field is available when Link Type is set as Trunk Link and Hybrid Link Assign a number in the range between 1 an 4094 Click Apply to have the configuration take effect You can see the link type untagged VID and tagged VID information of each port in the table below on the screen EQUITEL Technical Manual N965 77 exe Jan 2013 Ed 2 01 GVRP Mode Disable Management VLAN ID o Apply Link Type Untagged VID Port 01 mh Port o2 access m Port o3 access ml Port o4 access fi Portos access HE Port o6 Access _ Port07 Access _ Portos Access m arresa s 6 24 2 Switch Status Tagged VIDs mpm Behe mm m You can see the status of VLAN setting in this function VLAN Switch Status VLAN ID Untagged Ports Tagged Ports 1 1 2 3 4 5 5 7 8 9 10 EQUITEL Technical Manual N965 78 Jan 2013 Ed 2 01 6 25 QoS Quality of Service QoS is the ability to provide different priority to different applications users or data flows or to guarantee a certain l
70. le sas amas ss aas ss ss amas 7 DSCP 48 Priority High es x m 7 m DSCP 56 Priority High Tu EQUITEL Technical Manual N965 83 D 6 25 Port Mirroring The Port mirroring is a method for monitor traffic in switched networks Traffic through ports can be monitored by one specific port which means traffic goes in or out monitored source ports will be duplicated into mirror destination port Destination Port There is only one port can be selected to be destination mirror port for monitoring both RX and TX traffic which come from source port Or use one of two ports for monitoring RX traffic only and the other one for TX traffic only User can connect mirror port to LAN analyzer or Netxray W Source Port The ports that user wants to monitor All monitored port traffic will be copied to mirror destination port User can select multiple source ports by checking the RX or TX check boxes to be monitored m And then click Apply button Port Settings Destination Port Source Port Port Port O1 Port 02 03 04 05 Port 06 Port 07 Port 08 G1 G2 Apply Help RX C C C C C e C OE OE ORY OR De CURL O e Le E PTH S EQUITEL Technical Manual N965 84 Jan 2013 Ed 2 01 CQUITEL 6 26 Security You can blo
71. losed circuit will open when the l l failure occurs r F Fault Alarm Contacts amp 4 EQUITEL Technical Manual N965 17 exl gt Jan 2013 Ed 2 01 3 6 Cabling W Use four twisted pair Category 5e or above cabling for RJ 45 port connection The cable between the switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft long Fiber segment using single mode connector type must use 9 125 um single mode fiber cable User can connect two devices in the distance up to 30km W Fiber segment using multi mode connector type must use 50 or 62 5 125 um multi mode fiber cable User can connect two devices up to 2km distances B Gigabit Copper SFP mini GBIC combo port The Industrial switch has the auto detected Giga port Gigabit Copper SFP combo ports The Gigabit Copper 10 100 1000T ports should use Category 5e or above UTP STP cable for the connection up to 1000Mbps The small form factor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication and data communications The SFP slots supporting dual mode can switch the connection speed between 100 and 1000Mbps They are used for connecting to the network segment with single or multi mode fiber You can choose the appropriate SFP transceiver to plug into the slots Then use proper multi mode or single mode fiber according to the transceiver With fiber optic it transmits at
72. nd time saving time if SNTP switchZconfigure Format yyyymmdd function is inactive switch config sntp daylight hh mm this command can t be period 20120808 01 01 applied 20120809 01 01 Parameter format yyyymmdd hh mm ntp daylight offset G Set offset of daylight switch gt enable Minute saving time if SNTP switchZconfigure function is inactive switch config sntp daylight this command can t be offset 60 applied show sntp P Show SNTP switch gt enable information switch show sntp show sntp timezone P Show index number of switch gt enable time zone list switch show sntp timezone no sntp G Disable SNTP function switch gt enable switch configure switch config no sntp no sntp daylight G Disable daylight switch gt enable saving time switch configure switch config no sntp daylight LLDP Commands Set Netstar Commands Level Description Example enable G Enable LLDP function switch gt enable switch configure switch config enable interval G Configure LLDP switch gt enable TIME sec interval switch configure EQUITEL Technical Manual N965 107 CQUITEL Jan 2013 Ed 2 01 switch config lldp interval 1800 synctime Enable disable switch gt enable enable disable sync time switch configure switch config lldp synctime enable show P Show LLDP switch gt enable information switch show no G Disable LLDP switch gt enable sw
73. neto us Reus 8 9 LED Ingieal9fSu uu uu u uu OU 10 Hardware Installation 12 Installation Steps 12 DIN Rail Mounting 13 Wall Mount Plate Mounting 15 Wiring the Power Inputs 16 Wiring the Fault Alarm Contact 17 ie lue uu u Rr 18 Network Application 23 Pro Ring2s Application 24 Console Management 25 Connecting to the Console Port 25 Pin Assignment 25 Login in the Console Interface 26 CLI 28 EQUITEL Technical Manual N965 Jan 2013 Ed 2 01 CQUITEL Chapter 6 Web Based Management 29 6 1 About Web based Management 29 6 2 Preparing for Web Management 29 63 Systemi u a 30 i217 31 6 5 Time SINTP aei 34 6 6 Account Admin 37 6 7 IP Addressing 1 4 38 FO a 40 Syslog Configuration 40 6 9 SNMP Configuration
74. network problems and plan for network growth Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP SNMP Agent m Agent Mode Select the SNMP version V1 V2c or V3 that you want to use it And then click Change to switch to the selected SNMP version mode m SNMP V1V2c Community Here you can define the new community string set and remove the unwanted community string Community String Fill the name string Privilege Read only Enables requests accompanied by this community string to display MIB object information Read write Enables requests accompanied by this community string to display MIB object information and to set MIB objects gt Click Apply EQUITEL Technical Manual N965 41 exe Agent Jan 2013 Ed 2 01 SNMP Agent Version SNMPV1 V2c Community String Privilege public Read Only private 4090000003286046000002 SNMP Agent Configuration interface EQUITEL Technical Manual N965 42 PN ul gi m Jan 2013 Ed 2 01 6 20 1 SNMP Trap Configuration A trap manager is a management station that receives the trap messages generated by the switch If no trap manager is defined no traps will be issued To define a management station as a trap manager assign an IP address enter the SNMP community strings and select the SNMP trap version Server IP Enter the IP addres
75. nfiguration LLDP Protocol Pull down the selection menu to disable or enable LLDP function LLDP Interval Set the interval of advertising the switch s information to other nodes Sync Time How long will the switch Sync the LLDP information Click Apply LLDP LLDP Configuration LLDP Setting Protocol Enable Interval 30 sec Sync Time Disable Apply Help LLDP Interface EQUITEL Technical Manual N965 71 EQUITEL 6 22 1 LLDP Neighbors It will show you the information about Port Neighbor via LLDP protocol D LLDP LLDP Neighbours r Port System Name MAC Address IP Address EQUITEL Technical Manual N965 Jan 2013 Ed 2 01 72 6 23 Filtering Database 9 Use the MAC address table to ensure the port security 6 23 1 Configuration MAC Address Configuration Set the Aging time of MAC address table and define the event about port fail will influent the MAC table automatically or not Port Setting Define which port will be managed by Static MAC address table B Click Apply Filtering Data Base Configuration _ MAC Address Configuration F MAC Address Table Aging Time 0 3825 300 secs Auto Flush MAC Address Table When Ports Link Down Apply _ Port Setting Port No Security Port 02 Disable Port 03 Disable Port 04 Disable Port 05 Disable Port 06 Disable Port 07 Disable v Port
76. on time zone The following table lists the different location time zone for your reference Local Time Zone November Time Zone 1 hour 11am Oscar Time Zone 2 hours 10 am ADT Atlantic Daylight 3 hours 9 am AST Atlantic Standard 4 hours 8 am EDT Eastern Daylight EST Eastern Standard 5 hours Central Daylight CST Central Standard 6 hours 6 am MDT Mountain Daylight MST Mountain 7 hours 5am Standard EQUITEL Technical Manual N965 34 PDT Pacific Daylight PST Pacific Standard 8 hours 4 am ADT Alaskan Daylight ALA Alaskan Standard 9 hours 3 am 2 HAW Hawaiian 10 hours Standard 1 am Nome Alaska 11 hours CET Central European FWT French Winter MET Middle European MEWT Middle 1 hour European Winter SWT Swedish Winter EET Eastern European USSR Zone 1 BT Baghdad USSR 3 hours pm Zone 2 2 hours 2pm 4pm 2 4 USSR Zone 3 4 hours ZP5 USSR Zone 4 5 hours 5 pm 2 6 USSR Zone 5 6 hours 6 pm 7 hours 7 pm WAST West Australian Standard CCT China Coast 8 hours 8 pm USSR Zone 7 JST Japan Standard USSR Zone 8 EAST East Australian EQUITEL Technical Manual N965 9 hours 9 pm 10 hours 10 pm I gt 35 Standard GST Guam Standard USSR
77. ps below to mount the industrial switch with wall mount plate Remove the DIN Rail from the industrial switch loose the screws to remove the DIN 1 2 Place the wall mount plate on the rear panel of the industrial switch Rail 3 Use the screws to screw the wall mount plate on the industrial switch 4 Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall 5 To remove the wall mount plate reverse the above steps EQUITEL Technical Manual N965 Jan 2013 Ed 2 01 EQUITEL 3 4 Wiring the Power Inputs D Please follow the steps below to insert the power wire 1 Insert AC or DC power wires into the contacts 1 and 2 for power 1 or 5 and 6 for power 2 Tighten the wire clamp screws for preventing the wires from loosing NOTE The wire gauge for the terminal block should be in the range between 12 24 AWG EQUITEL Technical Manual N965 16 D 3 5 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below Inserting the wires the switch will detect the fault status of the power failure or port link failure available for managed model and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts NOTE The wire gauge for the terminal block should be in the range between 12 24 AWG Industrial Switch The c
78. r After the user clicks Apply a popup dialog shows up to inform the user that when the DHCP client is enabled the current IP will lose and user should find the new IP on the DHCP server m Address Assign the IP address that the network is using If DHCP client function is enabled this switch is configured as a DHCP client The network DHCP server will assign the IP address to the switch and display it in this column The default IP is 192 168 16 1 or the user has to assign an IP address manually when DHCP Client is disabled B Subnet Mask Assign the subnet mask to the IP address If DHCP client function is disabled the user has to assign the subnet mask in this column field B Gateway Assign the network gateway for the switch If DHCP client function is disabled the user has to assign the gateway in this column field The default gateway is 192 168 16 254 EQUITEL Technical Manual N965 38 i DNS 1 Assign the primary DNS IP address m DNS2 Assign the secondary DNS IP address m And then click Apply IP Addressing IP 4 IP Setting DHCP Client Disable gt IP Address 192 168 16 2 Subnet Mask 255 255 255 0 Gateway 192 168 16 254 DNS1 pooo DNS2 pono IP Addressing interface EQUITEL Technical Manual N965 39 D 6 8 Syslog This page allows the user to decide whether to send the system event log and select the mode which the system event log will be sent to client only serve
79. r only or both client and server What kind of event log will be issued to the client server depends on the selection on the Event Configuration tab There are four types of event Device Cold Start Authentication Failure X Ring Topology Change and Port Event available to be issued as the event log Syslog Configuration Syslog Configuration Configuration SYSLOG Mode Disable SYSLOG Server IP Address p 5 0 0 Syslog Configuration interface B Syslog Mode Select the system log mode Client Only Server Only or Both Client Only means the system event log will only be sent to this interface of the switch but on the other hand Server Only means the system log will only be sent to the remote system log server with its IP assigned If the mode is set in Both the system event log will be sent to the remote server and this interface SysLog Server IP Address When the Syslog Mode item is set as Server Only Both the user has to assign the system log server IP address to which the log will be sent B sure the selected mode is correct and click Apply to have the setting take effect EQUITEL Technical Manual N965 40 6 9 SNMP Configuration Simple Network Management Protocol SNMP is the protocol developed to manage nodes servers workstations routers switches and hubs etc on an IP network SNMP enables network administrators to manage network performance find and solve
80. r receiving SMTP event alert Provides one relay output for port breakdown power fail Relay Alarm Alarm Relay current carry ability 1 DC24V Support ingress packet filter and egress packet limit 1 Topology Change SNMP Trap 2 Power Trap 3 MAC Violation EQUITEL Technical Manual N965 PUN m gt Jan 2013 Ed 2 01 DHCP Provides DHCP Client DHCP Server Port and IP Binding Provides DNS client feature and supports Primary and Secondary DNS server Firmware Update Supports TFTP firmware update TFTP backup and restore Configuration Supports binary format configuration file for system quick Upload Download installation Each port allows importing 128bits of alphabetic string of ifAlias Supports SNTP to synchronize system clock in Internet word on SNMP and CLI interface EQUITEL Technical Manual N965 1 3 Package Contents Please refer to the package content list below to verify them against the checklist 810 100TX 2 10 100 1000T Dual Speed SFP Combo Managed Industrial Switch x 1 User manual x 1 Pluggable Terminal Block x 1 Mounting plate x 2 RJ 45 to DB9 Female cable x 1 Compare the contents of the industrial switch with the standard checklist above If any item is damaged or missing please contact the local dealer for service EQUITEL Technical Manual N965 Chapter 2 Hardware Description In this paragraph it will describe the Industrial switch s
81. re switch config igmp query interval 100 query response interval G Configure Query switch gt enable 1 250 tenths of a sec Response Interval switch configure switch config igmp query response interval 100 show igmp Show IGMP switch gt enable configuration configuration switch show igmp configuration show igmp table P Show IGMP snooping switch enable table switch show igmp table no igmp G Disable IGMP switch gt enable snooping function switch configure switch config no igmp no igmp query G Disable IGMP query switch enable switch configure switch config no igmp query Multicast Static Filtering Table Commands Set Netstar Commands Level Description Example multicast filtering IP_addr Configure multicast filtering entry of interface switch gt enable switch configure switch config interface fastEthernet 2 switch config multicast filtering 225 100 100 100 no multicast filtering IP_addr Remove multicast filtering entry of interface switch gt enable switch configure switch config interface EQUITEL Technical Manual N965 124 Jan 2013 Ed 2 01 fastEthernet 2 switch config if no multicast filtering 225 100 100 100 show multicast filtering Show multicast filtering table switch gt enable switch show multicast filtering IP Security Commands Set Netstar Commands Level Description Example security en
82. re Setting PwR1 PwR 2 Port Link Down Broken Setting Port 01 Port 02 Port o3 Port 04 Port 05 Port 06 Port 07 Port 08 Port 09 Port 10 Fault Relay Alarm interface 6 8 1 System Alert SMTP Simple Mail Transfer Protocol SMTP is the standard for email transmissions across the network You can configure the SMTP server IP mail subject sender mail account password and the recipient email addresses which the e mail alert will send to There EQUITEL Technical Manual N965 44 are also five types of event Device Cold Start Authentication Failure X Ring Topology Change and Port Event available to be issued as the e mail alert Besides this function provides the authentication mechanism including an authentication step through which the client effectively logs in to the SMTP server during the process of sending e mail alert B Email Alert With this function being enabled the user is allowed to configure the detail settings for sending the e mail alert to the SMTP server when the events occur m SMTP Server IP Assign the mail server IP address when Email Alert is enabled this function will then be available Sender Email Address Type in an alias of the switch in complete email address format e g switch101 123 com to identify where the e mail alert comes from m Mail Subject Input the subject of Email Authentication Having ticked this che
83. roup switch configure nolacp GroupID 1 3 switch config aggregator group Port list Member port 1 2 4 nolacp list This parameter or could be a port switch config aggregator group range ex 1 4 or a port 1 3 1 2 nolacp list separate by a comma ex 2 3 6 show aggregator Show the information switch gt enable of trunk group switch show aggregator 1 or switch show aggregator 2 or switch show aggregator 3 no aggregator lacp G Disable the LACP switch gt enable GroupID function of trunk group switch configure switch config no aggregator lacp 1 no aggregator group G Remove a trunk group switch gt enable GroupID switch configure switch config no aggregator group 1 PRO RING IIS Commands Set Netstar Commands Level Description Example prorstp enable Enable PRO RING IIS for this interface switch gt enable switch configure switch config interface fastEthernet 2 switch config if prorstp enable prorstp root Configure PRO RING switch gt enable EQUITEL Technical Manual N965 115 CQUITEL Jan 2013 Ed 2 01 disable enable backup IIS ROOT switch configure switch config prorstp root enable no prorstp Disable PRO RING IIS switch gt enable for this interface switch configure switch config interface fastEthernet 2 switch config if no prorstp no prorstp G Disable PRO RING IIS switch enable for all
84. rror fragments and jabbers via this port Tx Abort Packet The aborted packet while transmitting Packet Collision The counts of collision packet Packet Dropped The counts of dropped packet Rx Bcast Packet The counts of broadcast packet Rx Mcast Packet The counts of multicast packet Click Clear button to clean all counts EQUITEL Technical Manual N965 54 Jan 2013 Ed 2 01 Port Port Statistic TX Good TX Bad RX Good RX Bad TX Abort Packet Drop RX Beast Mcast TX Mcast Port Type Link State Packet Packet Packet Packet Packet Collision Packet Packet Packet Packet Port d1 100TX Down Enable 0 0 0 0 0 Port 02 100TX Down Enable 0 0 0 Port 03 1007 Down Enable Port 04 100TX Down Enable Port 05 100TX Down Enable Port 06 100TX Up Enable 245122 Port 07 100TX Down Enable 0 Port 08 100TX Down Enable Port 09 1GTX SFP Down Enable 0 Port 10 1GTX SFP Down Enable 52994 181467 CON X2 REUS D O OM Gas XO NS O MS I O m GH O O Port Statistics interfac EQUITEL Technical Manual N965 55 Jan 2013 CQUITEL 2 01 Port Port Alert Having ticked the Syslog SMTP checkboxes the event log email alert will be sent to the system log server and the SMTP server respectively Also Port event log alert link up link down and both can be sent to the system log server SMTP server Ed 6 15 respectively by setting the trigger condition System e
85. s network administration because the software keeps track of IP addresses rather than requiring an administrator to manage the task This means that a new computer can be added to a network without the hassle of manually assigning it a unique IP address The system provides the DHCP server function Having enabled the DHCP server function the switch system will be configured as a DHCP server 6 6 1 DHCP Server Server configuration B DHCP Server Enable or Disable the DHCP Server function Enable the switch will be the DHCP server on your local network Start IP Address Type in an IP address Low IP address is the beginning of the dynamic IP range For example dynamic IP is in the range between 192 168 16 100 192 168 16 200 In contrast 192 168 16 100 is the Low IP address m End IP Address Type in an IP address High IP address is the end of the dynamic IP range For example dynamic IP is in the range between 192 168 16 100 192 168 16 200 In contrast 192 168 16 200 is the High IP address Subnet Mask Type in the subnet mask of the IP configuration Gateway Type in the IP address of the gateway in your network DNS Type in the Domain Name Server IP Address in your network Lease Time Hour It is the time period that system will reset the dynamic IP assignment to ensure the dynamic IP will not been occupied for a long time or the server doesn t know that the dynamic IP is idle B Andthen click Apply EQUITEL
86. s T1 6 22 1 LLDP Neighbors esses 72 6 23 Filtering Database 73 Dod VEAN dn bn bas 75 6 24 1 VLAN Conftfiguration 75 6 24 2 Switch Status 78 Pu QU E 79 6 25 1 Global Settings 79 6 25 2 Port uu 80 6 25 3 COS Mapping to Queue 81 6 25 4 DSCP mapping to queue 82 6 25 Port u u 84 06 26 SECUN Y e 85 6 26 1 IP Source Guard Configuration 85 6 26 2 IP Source Guard Static Table 86 6 26 3 BOIS u u oan u 87 6 26 4 MAC Filtering 91 6 26 5 Port Security 92 You can block the un authorized MAC by oer port in this function 92 EQUITEL Technical Manual N965 Jan 2013 Ed 2 01 Fe JEQUITOL 6 27 Maintenance 93 6 27 1 Save Configuration 93 Troubles STIOODU DE ee s EK MD PR FAM PUES 98 Appendix A RJ 45 Pin Assignment 99 RJ 45 Pin Assignments 99 RJ 45 Pin Assignment of PoE
87. s of the trap manager Community Enter the community string for the trap station Trap Version Select the SNMP trap version type v1 or v2c m Click Add To remove the community string select the community string listed in the current managers field and click Remove Trap Server Setting F Server IP Community Trap Version C yor Add Trap Server Profile Server IP Community Trap version Remove Trap Managers interface EQUITEL Technical Manual N965 43 D 6 10 System Alert Relay Alarm The Fault Relay Alarm function provides the Power Failure and Port Link Down Broken detection With both power input 1 and power input 2 installed and the check boxes of power 1 power 2 ticked the FAULT LED indicator will then be possible to light up when any one of the power failures occurs As for the Port Link Down Broken detection the FAULT LED indicator will light up when the port failure occurs certainly the check box beside the port must be ticked first Please refer to the segment of Wiring the Fault Alarm Contact for the failure detection m Power Failure Setting Tick the check box to enable the function of lighting up the FAULT LED on the panel when power fails m Port Link Down Broken Setting Tick the check box to enable the function of lighting up FAULT LED on the panel when Ports states are link down or broken System Alert Relay Alarm Power Failu
88. show poe schedule show poe P Show Power over Ethernet information switch gt enable switch poe switch show poe Save Configuration Commands Set Netstar Commands Level Description Example write memory P Save user configuration into permanent memory flash rom switch gt enable switch write memory Factory Default Commands Set Netstar Commands Level Description Example default G Restore to factory switch gt enable keepip keepadmin both default configuration switch configure switch config default both EQUITEL Technical Manual N965 137 Jan 2013 Ed 2 01 i Con Reboot Commands Se Set switch gt enable G Rebootswith switch configure switch config reload reload Logout Commands Set E Logout command line switch gt logout shell logout 138 EQUITEL Technical Manual N965
89. still cannot resolve the problem contact the local dealer for assistance If the LED indicators are normal and the connected cables are correct but the packets still cannot be transmitted Please check the user system s Ethernet devices configuration or status EQUITEL Technical Manual N965 98 1T E CTI Jan 2013 Ed 2 01 Appendix A RJ 45 Pin Assignment RJ 45 Pin Assignments The UTP STP ports will automatically sense for Fast Ethernet 10Base T 100Base TX connections or Gigabit Ethernet 10Base T 100Base TX 1000Base T connections Auto MDI MDIX means that the switch can connect to another switch or workstation without changing straight through or crossover cabling See the figures below for straight through and crossover cable schematic B 10 100BASE TX Pin outs With10 100BASE TX cable pins 1 and 2 are used for transmitting data and pins 3 and 6 for receiving data B RJ 45 Pin Assignments Pin Number Assignment 1 TX 2 Tx 3 Rx 6 Rx NOTE and signs represent the polarity of the wires that make up each wire pair The table below shows the 10 100BASE TX MDI and MDI X port pin outs Pin Number MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data plus TD 2 Receive Data minus RD Transmit Data minus TD 3 Transmit Data plus TD Receive Data plus RD 6 Transmit Data minus TD Receive Data minus RD
90. tag UntaggedVID tag TaggedVID List Assign a qinq link for VLAN by trunk group switch gt enable switch vlan database switch vlan vlan 80214 aggreator 3 hybrid link qinq untag 4 tag 3 6 8 or switch vlan vlan 80214 EQUITEL Technical Manual N965 120 CQUITEL Jan 2013 Ed 2 01 aggreator 3 hybrid link qing untag 5 tag 6 8 show vlan GroupID V Show VLAN switch gt enable 2 information switch vlan database show vlan switch vlan show vlan 2 no vlan GroupID V switch gt enable Delete port base group ID switch vlan database switch vlan zno vlan 2 SNMP Commands Set Netstar Commands Level Description Example snmp agent mode G Select the agent mode switch enable v1v2c v3 of SNMP switch configure switch config snmp agent mode viv2c snmp community G Add SNMP community switch gt enable strings Community string switch configure right switch config zsnmp community RO RW strings public right rw Snmp trap server G Configure SNMP switch gt enable IP address server host switch configure community information and switch config snmp trap server Community string community string 192 168 1 120 community public trap version trap version v2c v1 v2c snmp snmpv3 user G Create a SNMPv3 switch gt enable UserID Heer prolis switch configure password Authentication Password Privacy Password switch config snmp snmpv
91. that facilitates control of virtual local area networks VLANs within a larger network GVRP conforms to the IEEE 802 1Q specification which defines a method of tagging frames with VLAN configuration data This allows network devices to dynamically exchange VLAN configuration information with other devices Port Setting Select the port you want to configure e Link Type There are 4 types of link type 1 Access Link A segment which provides the link path for one or more stations to the VLAN aware device An Access Port untagged port connected to the access link has an untagged VID also called PVID After an untagged frame gets into the access port the switch will insert a four byte tag in the frame The contents of the last 12 bit of the tag is untagged VID When this frame is sent out through any of the access port of the same PVID the switch will remove the tag from the frame to recover it to what it was Those ports of the same untagged VID are regarded as the same VLAN group members Note Because the access port doesnt have an understanding of tagged frame the column field of Tagged VID is not available 2 Trunk Link A segment which provides the link path for one or more VLAN aware devices switches A Trunk Port connected to the trunk link has an understanding of tagged frame which is used for the communication among VLANs across switches Which frames of the specified VIDs will be forwarded depends on the values
92. tion Example show ddm P Show temperature alarm information switch gt enable switch show Loading Average Commands Set Netstar Commands Level Description Example loadavg E Show system load average switch gt loadavg event loadavg Systemlog SMTP Both Set system load average event type switch gt enable switch configure switch config event loadavg both Power over Ethernet Commands Set Netstar Commands Level Description Example poe P Enter POE configure switch gt enable mode switch poe system knockoff Set PoE system Port switch enable disabled Knockoff Disabled switch poe Enable Disable switch poe system knockoff disabled enable system ac disconnect Set PoE system switch enable EQUITEL Technical Manual N965 135 CQUITEL Jan 2013 Ed 2 01 Enable Disable Disconnect switch poe switch poe system ac disconnect enable system capacitive detect Enable Disable Set PoE system Capacitive Detection switch gt enable switch poe switch poe system capacitive detect enable port PortNumbers powerlimit Value Set Poe system Power Limit switch gt enable switch poe switch poe port 1 powerlimit 11000 port PortNumbers state Enable Disable Set PoE port State switch gt enable switch poe switch poe port 1 state disable
93. trol Disable flow control of interface switch gt enable switch configure switch config interface fastEthernet 2 switch config if no flowcontrol security enable Enable security of interface switch gt enable switch configure switch config interface fastEthernet 2 switch config if security enable no security Disable security of interface switch gt enable switch configure switch config interface EQUITEL Technical Manual N965 111 CQUITEL Jan 2013 Ed 2 01 fastEthernet 2 switch config if no security auto sfp Enable Disable Enable disable to auto detect 100 1000 SFP switch gt enable switch configure switch config auto sfp disable alias name Set port alias name switch gt enable switch configure switch config interface fastEthernet 2 switch config if alias 1111 show interface configuration show interface configuration status switch gt enable switch configure switch config interface fastEthernet 2 switch config if show interface configuration Port Status Commands S et Netstar Commands Level Description Example show interface status show interface actual status switch gt enable switch configure switch config interface fastEthernet 2 switch config if show interface status Rate Limit Commands Set Netstar Commands Level Description
94. unction switch configure switch config no dhcpserver Port Control Commands Set Netstar Commands Level Description Example interface fastEthernet Portid G Choose the port for modification switch gt enable switch configure switch config interface fastEthernet 2 state enable disable Use the state interface configuration command to specify the state mode of operation for Ethernet ports Use the disable form of this command to disable the port switch gt enable switch configure switch config interface fastEthernet 2 config if state disable duplex full half Use the duplex configuration switch gt enable switch configure EQUITEL Technical Manual N965 110 Jan 2013 Ed 2 01 command to specify the duplex mode of operation for Fast Ethernet switch config interface fastEthernet 2 switch config if duplex full speed 10 100 1000 auto Use the speed configuration command to specify the speed mode of operation for Fast Ethernet the speed can t be set to 1000 if the port isn t a giga port switch gt enable switch configure switch config interface fastEthernet 2 switch config if speed 100 flowcontrol mode symmetric asymmetric Configure flow control switch gt enable switch configure switch config interface fastEthernet 2 switch config if flowcontrol mode asymmetric no flowcon
95. up to 12 hours m Click Apply to have the configuration take effect EQUITEL Technical Manual N965 36 Jan 2013 Ed 2 01 SNTP Client Setting SNTP Client Disable x UTC Timezone GMT Greenwich Mean Time Dublin Edinburgh Lisbon London SNTP Server Address 4 Daylight Saving Setting Daylight Saving Time Disable j D z 7 E z Daylight Saving Period ens I A Daylight Saving Offset o hours SNTP Configuration interface 6 6 Account Admin Change web management login user name and password for the management security issue User name Type in the new user name The default is root B New Password Type in the new password The default is root m Confirm password Re type the new password B And then click Apply EQUITEL Technical Manual N965 37 Account Admin Username amp Password User Name root New Password Confirm Password Account Authentication interface 6 7 IP Addressing IPV4 The switch is a network device which needs to be assigned an IP address for being identified on the network Users have to decide a means of assigning IP address to the switch B DHCP Client Enable or disable the DHCP client function When DHCP client function is enabled the switch will be assigned an IP address from the network DHCP server The default IP address will be replaced by the assigned IP address on DHCP serve
96. vent selection There are 3 event types Device Cold Start Authentication Failure and X ring Topology Change The checkboxes are not available for ticking unless the Syslog Client Mode on the Syslog Configuration tab and the E mail Alert on the SMTP Configuration tab are enabled first Device cold start When the device executes cold start action the system will issue the event log email alert to the system log SMTP server Authentication Failure When the SNMP authentication fails the system respectively will issue the event log email alert to the system log SMTP server respectively MAC Violation When the MAC address has violated the system will issue the event log email alert to the system log SMTP server respectively Port event selection Also before the drop down menu items are available the Syslog Client Mode selection item on the Syslog Configuration tab and the E mail Alert selection item on the SMTP Configuration tab must be enabled first Those drop down menu items have 3 selections Link UP Link Down and Link UP amp Link Down Disable means no event will be sent to the system log SMTP Server Link UP The system will only issue a log message when the link up event of the port occurs Link Down The system will only issue a log message when the link down event of port occurs Link UP amp Link Down The system will issue a log message at the time when port connection is link up and link down
97. y switch process too many network packets So the network throughput was keeping decreasing In this option you can monitor the CPU of switch to see if the switch was in full loading status or not EQUITEL Technical Manual N965 32 General CPU Load Average Loading Average 100 90 80 70 50 40 30 18 dd 14544 H4 Bese 3 2 1 Loading Average 1min Smins 15 mins 0 0 0 EQUITEL Technical Manual N965 33 6 5 Time SNTP SNTP Simple Network Time Protocol is a simplified version of NTP which is an Internet protocol used to synchronize the clocks of computers to some time reference Because time usually just advances the time on different node stations will be different With the communicating programs running on those devices it would cause time to jump forward and back a non desirable effect Therefore the switch provides comprehensive mechanisms to access national time and frequency dissemination services organize the time synchronization subnet and the local clock in each participating subnet peer Daylight saving time DST is the convention of advancing clocks so that afternoons have more daylight and mornings have less Typically clocks are adjusted forward one hour near the start of spring and are adjusted backward in autumn B SNTP Client Enable disable SNTP function to get the time from the SNTP server m UTC Timezone Universal Time Coordinated Set the switch locati

Download Pdf Manuals

image

Related Search

User manual user manual user manual bosch dishwasher user manual for this laptop user manual pdf user manual template user manual for frigidaire model fcrg3052bw user manual for gaomon user manuals free user manual examples user manual template word user manual for this hp computer user manual for samsung galaxy a14 5g user manual for iphone 14 user manuals free downloads user manual for amazon fire hd 10 tablet user manual smart watch user manual smart bracelet user manual for vizio tv user manual cg300 eyeglass recorder

Related Contents

Nº MODELO WV-SFV531/WV-SFR531/ WV-SFN531 - Psn  8ASI_DVB_S/S2 RF  Platinum™ - Invacare  User Guide Mode d'emploi  TM-181 Hygro-Thermometer說明書  ThermaK_ThermaK-Plus User Manual_A  TDSHーBA 東芝道路照明器具取扱説明書  PR4EN1ELEC / 515586  distySoS, Bedienungsanleitung  USER`S MANUAL FOR VEAVIEN DIMMER  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.