DELTA VFD-L sorozatú frekvenciaváltó - MOTOR

image

Contents

1. M 4 01 polarity 0 positive bias 1 negative bias 0 M 4 02 Potentiometer freq gain 1 200 100 4 03 Potenci m ter 0 nincs haszn lva 0 H traforgat si m d 1 H traforg s enged lyezve enged lyez se 2 Csak el reforg s 4 04 Multi function input 0 nincs haszn lva terminal1 M1 1 MO ELORE STOP M1 HATRA STOP 1 2 M0 FORGAS STOP M1 ELORE HATRA d 0 d 20 Multi function input 3 MO M1 M2 3 vezet kes vez rl si m d 4 05 terminal 2 M2 K ls hiba alapban nyitott N O 6 4 06 Multi function input K ls hiba alapban z rt N C 7 terminal 3 M3 RESET multi step speed command 1 multi step speed command 2 jog operation d0 d4 d20 CO OONO O1 10 Alap Param terek Funkci Be l t s i be ll t s 10 accel decel speed inhibit 11 first or second accel decel time selection 12 base block B B normally open N O 13 base block B B normally closed N C 4 06 Multi function input 14 increase master freq 7 terminal 3 M3 15 decrease master freq d 0 d 4 d 20 16 run PLC program 17 pause PLC 18 counter trigger signal 19 counter reset 20 select ACI deselect AVI 5 Csoport Mulit l pcs s sebess g s PLC param terek ns Alap Param terek Funkci Be ll t s be ll t s 5 00 1 l pcs frekvencia 0 0 400Hz 0 0 5 01 2 l pcs frekvencia 0 0 400Hz 0 0 5 02 3 l pcs frekvencia 0 0 400Hz 0 0 5
2. zettel K ls vez rl n kereszt l STOP gomb akt v K ls vez rl n kereszt l STOP gomb t ltva RS 485 6s kommunik ci s interf szen kereszt l STOP gomb akt v RS 485 s kommuni ci s interf szen kereszt l STOP gomb tiltva 0 10 Motor h traforgat si 0 H traforg s enged lyezve 0 m dja 1 H traforg s t ltva 2 El reforg s t ltva ACI 4 20mA 0 Lass t s OHz re 0 vez rl si bemenet kies s 4 Azonnali STOP hiba zenet ki r s 2 Utols frekvenci n val fut s 2 06 Line Start Lockout 0 Enged lyezve 1 Tiltva Group 3 Output Function Parameters y E Alap Param terek Funkci Be ll t s be ll t s 3 00 Desired freq attained 1 0 400 Hz 1 0 m eem pre rt ke e ia RS EL value nincs haszn latban 8 AC drive operational Max Output Freq Attained 0 sebess g T lnyomatk Base Block B B Alacsony fesz lts g felismer s AC Drive Operation Mode Fault Indication Desired Freq Attained 10 PLC Programm futtat s 11 PLC Program L p s v grehajt s 12 PLC Programm teljes t s 13 PLC Program pillanatnyi meg ll t sa 14 Terminal Count Value Attained 15 Preliminary Count Value Attained 16 K szenl ti llapot jelz s 0 1 2 3 4 5 6 7 8 9 ek Alap Param terek Funkci Bealitas be ll t s y 4 00 Potenciom ter bias freq 9 9 350Hz 0 0 Potentiometer bias s
3. 03 PLC m d 0 PLC m d tilt sa 0 1 1 programciklus futtatasa 2 Folyamatos programciklus lejatszas 3 Execute one program cycle step by step separate by STOP 4 Continuously execute one program cycle step by step separate by STOP 15 0 Forward 1 Reverse 0 cae ee motion Pee HK m CR Fee EK os Fee Oe Group 6 Protection Parameters Parameters Functions Settings Facto Dy Setting Prevention Level 350 410V Prevention Level 20 200 11 Factory Parameters Functions Settings Setting 6 02 Over torque 0 disable 0 detection 1 enable during constant speed operation and continues until the continuous limit is reached 2 enabled during constant speed operation and halted after detection 3 enabled during accel and continues before continuous output time limit is reached 4 enabled during accel and halted after over torque detection ume ee n etection level te press o etection time 6 05 Electronic thermal 0 Not used 0 overload relay 1 Act with standard motor 2 Act with special motor characteristic 6 07 Present fault record 0 No fault occurred 0 fault record 2 ov over voltage eo Third most recent 3 oH over heat fault record 4 oL over load Forth most recent 5 oL 1 electronic thermal 9 jutecad EF external au e emu e fault record 8 9 ocA current exceed during acceleration Reserved i 6 42 9ixth most recent 16 ocd current exce
4. STOP keys Signal External Signal M0 M1 M2 M3 can be combined to offer various modes of operation RS 485 communication port Multi function Input Signal Multi step selection 0 to 3 Jog accel decel inhibit first second accel decel switch counter PLC Operation external Base Block NC NO selection Multi function Output Signal AC Drive Operating Frequency Attained Non zero speed Base Block Fault Indication Local Remote indication PLC Operation indication Other Function AVR S curve Over Voltage Stall Prevention DC Braking Fault Records Adjustable Carried Frequency Starting Frequency Setting of DC Braking Over Current Stall Prevention Momentary Power Loss restart Reverse Inhibition Frequency Limits Parameter Lock Reset Over Voltage Over Current Under Voltage Overload Electronic thermal FISISCHON Overheating Self testing Other Including EMI Filter Cooling Forced air cooling Environment Installation Location Altitude 1 000 m or below keep from corrosive gasses liquid and dust Ambient Temperature 10 C 40 C Non Condensing and not frozen Storage Temperature 20 C to 60 C Ambient Humidity Below 90 RH non condensing Vibration 9 80665m s 1G less than 20Hz 5 88m s 0 6Gat 20 to 50Hz 18 19
5. AM M M MM GD 0 75KW 230V IPHASE s on DV ND O Ne a 7 SLA ae a C i O ji c T B a a FT KE l J l N Ne NN 7 q VDO ZE VOR ZA 3 KI DO CAL A N CAM X L GY T MR J 2 Fejezet BEKOTES Alap bekot si diagram Az inverter pontos bek t se rdek ben k rem ellen rizze hogy az al bbi bra szerint j rt e el K rj k ezen fel l tartsa be az n orsz g ra vontkoz m s bek t si szab lyokat is SHE ER H l zati bek t s ie au BRM Vez rl ramk r bek t s Megjegyz s K REM FIGYELMESEN OLVASSA EL AZ AL BBI PONTOKAT 1 AN FIGYELEM Ne k sse az inverter U T1 V T2 W T3 termin l kapcsaira a h l zati k belt 2 AN VESZ LY Elen rizze hogy minden csavar meg van h zva az annak megfelel nyomat kkal 3 ADuring installation follow all national and local electrical construction and safety codes for the country the drive is to be i
6. Anetta wl VFD L Felhaszn l i k zik nyv 115V 200W 400W 230V 200W 2HP Egyszeru ltal nos celu AC frekvenciav lt Bevezeto Thank you for choosing DELTA s VFD L series AC Drive The VFD L series is manufactured using high quality components material and incorporating the latest microprocessor technology available This manual will help in the installation parameter setting troubleshooting and daily maintenance of the AC motor drive To guarantee safe operation of the equipment read the following safety guidelines before connecting power to the AC motor drive Keep this operating manual handy and distribute to all users for reference Important Notes DANGER AC input power must be disconnected before any maintenance Do not connect or disconnect wires while power is applied to the circuit Only qualified technicians should perform maintenance on the VFD L CAUTION There are highly sensitive MOS components on the printed circuit boards These components are especially sensitive to static electricity To avoid damaging these components do not touch the circuit boards with metal objects or your bare hands DANGER A charge may still remain in the DC link capacitor with hazardous voltages even after the power has been turned off To avoid personal injury do not remove the cover of the AC drive until all DISPLAY LED lights on the digital keypad are off Please note that there are live components exposed when the AC dr
7. axim lis m k d si frek 50 0 400Hz 60 0 Maxim lis m k d si frek 10 0 400Hz 60 0 Maxinalis Kimengi So aay 220 fesz lts g K z pponti frekvencia 1 0 400Hz 1 0 K z pponti fesz lts g 2 0 255V 12 0 Minim lis kimen frek 1 0 60 0Hz 1 0 Minimes KIMEN 205255 12 0 fesz lts g Upper bound of freq 1 110 100 Lower bound of freq 0 100 0 0 Gyors t si id 1 Tacc1 0 1 600 Sec 10 0 Alap beallitas 1 10 Lass t si id 1 Tdec1 0 1 600 Sec 10 0 10 0 10 0 1 13 JOG Gyorsitasi id 0 1 600 Sec 10 0 JOG Lassitasi id 0 0 600 Sec 10 0 Param terek Funkci Be ll t s JOG frekvencia 1 0Hz 400Hz 6 0 Auto Gyors t s Lass t s Line ris Gyors t s Lass t s 0 Automatikus Gyors t s line ris lass t s Line ris Gyors t s automatikus lass t s Auto Gyorsitas Lassitas Linearis Gyorsitas Automatikus lassitas le ll si v delem a lassitaskor Automatikus Gyorsitas leallas elleni v delem a lassitaskor S Gorbe beallitasa 1 17 p 0 7 0 gyors t skor 1 18 S G rbe be ll t sa 0 7 0 lassitaskor 2 Csoport M k d si m d be ll t si param terei Alap Param terek Funkci Be ll t s be ll t s Frekvencia ll t si Digit lis billenty zet 0 beviteli forr sa 0 10V AVI 4 20mA AVI Controlled by V R on drive RS 485 kommunik ci s interface en at Utas t si parancs beviteli 0 forr sa Digit lis billenty
8. ed during deceleration Reserved fault record 11 ocn current exceed during steady state Group 7 Motor Parameters Parameters Functions Settings gt Motor rated current 30 120 85 24 7 01 Motor no load current 0 90 9 50 x ums omes 1 compensation M 7 03 Slip compensation 0 0 Group 8 Special Parameters Parameters Functions Settings S 8 00 DC braking voltage level 0 30 0 800 80 DC braking time during ORO SS 0 0 start up 12 Factory Parameters Functions Settings Setting 8 02 PG braking time during 9 9 60 0 Sec 0 0 stopping 8 03 Start point for DC braking 0 0 400 0 Sec 0 0 Momentary power loss 0 Stop operation after momentary power 0 loss 1 Continues after momentary power loss speed search starts with master freq 2 Continues after momentary power loss speed search starts with min output freq 8 05 es allowable power loss 0 3 5 0 Sec 20 8 06 B B time for speed search 0 3 5 0 Sec 0 5 a speed search eurent 30 200 30 20 0 200 150 Skip freq 1 upper bound 0 0 L 809 Skip freq 1 lower bound 0 0 400 Hz 0 0 8 10 Skip freq 2 upper bound 0 0 400Hz 00 8 11 Skip freq 2 lower bound 0 0 400 Hz TO 8 12 Skip freq 3 upper bound 0 0 400 Hz 1 1 00 8 13 Skip freq 3 lower bound 0 0 400Hz 8 1 0 0 8 14 Auto restart after fault 0 10 1 1 0 8 15 AVR functi
9. ive is open Be careful to not touch these live parts CAUTION Ground the VFD L using the ground terminal 2 The grounding method must comply with the laws of the country where the AC drive is to be installed DANGER The AC drive may be destroyed beyond repair if power is misapplied to the input output terminals Never connect the AC drive output terminals U T1 V T2 W T3 directly to the AC main circuit power supply 1 Fejezet KICSOMAGOLAS ES SZEMREV TELEZ S This VFD L AC drive has gone through rigorous quality control tests at the factory before shipment Since many things may happen during shipping please check for the following after receiving the AC motor drive Inspect the unit to insure it was not damaged during shipment Make sure that the part number indicated on the nameplate corresponds with the part number of your order Adattaba magyar zata P lda inverter 1HP230V SERA BRR Tipus meghatarozas SHR BRR Sz riasz m magyar zata SERA BRR Ha b rmilyen adat nem egyezik az adatablan az n ltal rendelt inverter tipshoz k pest k re l pjen kapcslatba az n ltal legk elebbi forgalmaz val M retek VFD L A WARNING Do not connect AC power to output P terminals U V W Do not inspect components until LED iU are turned off for at least 1min Read the user manual before operati po ooooodvG RC V
10. nstalled in 4 Ensure the appropriate protective devices circuit breaker or fuses are connected between the power supply and AC drive 5 Make sure that the leads are connected correctly and the AC drive is properly grounded Ground resistance should not exceed 0 10 6 Use ground leads that comply with AWG MCM standards and keep them as short as possible 7 Multiple VFD L units can be installed in one location All the units should be grounded directly to a common ground terminal The VFD L ground terminals may also be connected in parallel as shown in the figure below Ensure there are no loops du 8 When the AC drive output terminals U T1 VIT2 and W T3 are connected to the motor terminals U V and W respectively the motor will rotate counterclockwise as viewed from the shaft ends of the motor when a forward operation command is received To reverse the direction of motor rotation switch over any of the two motor leads 9 Make sure that the power is capable of supplying the correct voltage and required current to the AC drive 10 Do not attach or remove wiring when power is applied to the AC drive 11 Do not monitor the signals on the circuit board while the AC drive is in operation 12 Route the power and control wires separately or orthogonal to each other 13 If a filter is required for reducing EMI Electro Magnetic Interference install it as close as possible to AC drive EMI can also be reduced by l
11. off under N O E F Motor overload Check the 1 Reduce the motor load parameter settings Pr 6 03 to 2 Adjust the over torque detection setting to an Pr 6 05 appropriate setting ai Internal electronic overload trip 15 Kiirt hibakod Hiba leirasa Javasolt korrekcio a hiba elharitasara Over current during acceleration 1 Check for possible poor insulation at the 1 Short circuit at motor output output line 2 Torque boost too high 2 Decrease the torque boost setting in Pr 7 02 Mr 3 Acceleration time too short 3 Increase the acceleration time 4 AC drive output capacity is too 4 Replace with the AC drive with one that has a small higher output capacity next HP size Over current during deceleration 1 Check for possible poor insulation at the 1 Short circuit at motor output output line aca 2 Deceleration time too short 2 Increase the deceleration time 3 AC drive output capacity is too 3 Replace with the AC drive with one that has a small higher output capacity next HP size Over current during steady state operation 1 Check for possible poor insulation at the sb 1 Short circuit at motor output output line 2 Sudden increase in motor loading 2 Check for possible motor stall 3 AC drive output capacity is too 3 Replace with the AC drive with one that has a higher output capacity next HP size 1 Switch off power supply Internal memory IC can not be 2 Check whethe
12. on 0 AVR function enable 2 1 AVR function disable 2 AVR function disable when decel 8 16 Dynamic braking voltage 350 450V 380 _ 8 17 DC braking lower bound limit 0 0 400 Hz 0 0 Group 9 Communication Parameters Parameters Functions Settings panio ry Setting Communication address 1 247 1 Atviteli sebess g 0 Baud rate 4800 1 1 Baud rate 9600 2 Baud rate 19200 X 9 02 Transmission fault 0 Warn and continue running 0 treatment 1 Warn and ramp to stop 2 Warn and coasting stop 3 No warn and keep running Modbus communication 0 Disable 0 watchdog timer 1 20 1 20 Sec Communication ASCII 0 7 N 2 0 protocol mode 1 7 E 1 2 7 0 1 3 8 N 2 Factory Parameters Functions Settings Setting RTU mode 3 801 4 FEJEZET HIBAKERESES ES HIBA ZENET KI R S The VFD L AC drive has a comprehensive fault diagnostic system that includes several different alarms and fault messages Once a fault is detected the corresponding protective functions will be activated The following faults are displayed on the AC drive digital keypad The six most recent faults can be read on the digital keypad display by viewing Pr 6 07 to Pr 6 12 NOTE faults can be cleared by pressing the Reset key on the keypad or Input Terminal Common Problems and Solutions Check whether the motors horsepower corresponds to the AC drive output power Check the wiring connections between the AC dri
13. owering the Carrier Frequency 14 If the AC drive is installed in the place where a load reactor is needed install the filter close to U T1 V T2 W T3 side of AC drive Do not use a Capacitor or L C Filter Inductance Capacitance or R C Filter Resistance Capacitance 15 When using a GFCI Ground Fault Circuit Interrupt select current sensor with minimum current 200mA and minimum detection time 0 1 second to avoid nuisance tripping 3 Fejezet PARAMETER LISTA 0 s csoport Felhaszn l i param terek A A param terek egyr sze menetk zben is ll that m oie Alap Param terek Funkci Be ll t sok be ll t s 0 00 Beazonos t si k d 1 40W csak olvashato adat 2 100W 3 200W 4 400W 5 750W 6 1 5KW N vleges ramer ss g 40W 0 4A csak olvashat adat 100W 0 8A 200W 1 6A 400W 2 5A 750W 4 2A 1 5K 7 0A 0 Bejelentkez kijelz 0 F Frekvencia parancs 1 H kimen frekvencia 0 2 U gyf l specifikus egys g 3 A kimen ramer ss g gyf lspecifikus egys g 0 gyf l specifikus egys g kijelz se u 0 1 Sz ml l rt k kijelz s C 2 Utas t s v grehajt s kijelz se 1 tt 3 DC BUS fesz lts g nek kijelz se U 4 Kimen fesz lts g kijelz se E gyf l Spec lland K 1 0 Software verzi HH 0 07 Jelsz bevitel 199 0 0 1 Fejezet Alap Param terek z sz mo Alap Param terek Funkci Be ll t s be ll t s 1 00 M
14. r the input voltage falls within programmed the rated AC drive input voltage 3 Switch the AC drive back on 1 Check the connections between the main cre Internal memory IC can not be read control board and the power board 2 Reset parancs kiad sa Kapcsolja le a h l zatr l 2 Ellen rizze hogy az inverterbe bemen cr3 Drive s internal circuitry abnormal fesz lts g megfelel e a frekvenciav lt n vleges fesz lts g hez 3 Kapcsolja be az invertert HF Hardware v delmi hiba Reset parancs kiadasa cad Software v delmi hiba Reset parancs kiadasa crm Auto Gyors t si Lassitasi hiba unk Rie Urey Or sitastieaSeriae Check the connection between the AC drive and computer for loose wires Check if the communication protocol is properly set Kommunik ci s hiba External Base Block When the external input terminal B B is AC drive output is turned off active the AC drive output will be turned off Disable this connection and the AC drive will begin to work again 16 Kiirt hibakod Hiba leirasa The AC drive detects excessive drive output current Javasolt korrekci a hiba elh r t s ra Check whether the motor is overloaded 2 Reduce torgue compensation setting as set in Pr 7 02 Increase the AC drive s output capacity Note The AC drive can withstand up to 150 of the rated current for a maximum of 60 seconds 17 ltal nos m s
15. ve and motor for possible short circuits Increase the Acceleration time Pr 1 09 The AC drive detects an abnormal Pr 1 11 increase in current Check for possible excessive loading conditions at the motor If there are any abnormal conditions when operating the AC drive after the short circuit is removed the drive should be sent back to manufacturer Check whether the input voltage falls within The AC drive detects that the DC the rated AC drive input voltage nu bus voltage has exceeded its Check for possible voltage transients maximum allowable value Bus over voltage may also be caused by motor regeneration Increase the decel time Ensure that the ambient temperature falls within the specified temperature range Make sure that the ventilation holes are not is The AC drive temperature sensor obstructed detects excessive heat Remove any foreign objects on the heat sink and check for possible dirty heat sink fins Provide enough spacing for adequate ventilation n The AC drive detects that the DC Lu bus voltage has fallen below its minimum value Check whether the input voltage falls within the rated AC drive s input voltage 1 Check for possible motor overload 2 Check electronic thermal overload setting 3 Increase motor capacity 4 Reduce the current level so that the drive output current does not exceed the value set by the Motor Rated Current Pr 7 00 i from OFF to ON output will be turned
16. zaki param terek Voltage Class 115V 230V Model Number VFD L AB 002 004 002 004 007 015 Applicable Motor Output kW 0 2 0 4 0 2 0 4 0 7 1 5 o Rated Output Capacity KVA 0 6 1 0 0 6 1 0 1 6 27 c Rated Output Current A 1 6 25 1 6 25 4 2 7 0 3 phase corresponds 2 Max Output Voltage V to double input Three phase corresponds to input voltage o voltage Rated Freguency Hz 1 0 400Hz Rated Input Current A 6 9 4 9 1 9 6 5 2 7 9 7 5 1 9 f 3 phase 2 Single phase Single 3 phase x 6 oak Metz key t 90 132V 50 60Hz 180 264V 50 60Hz ns a 50 60Hz Frequency tolerance 5 Control system SVPWM Sinusoidal Pulse Width Modulation carried frequency 3kHz 10kHz Output Frequency Resolution 0 1Hz 0 i E sli i i 9 p F Torque Characteristics Including the auto torque auto slip pu starting torque can be 150 at C 8 Overload Endurance 150 of rated current for 1 minute 5 Accel Decel Time 0 1 600Sec can be set individually VIF pattern VIF pattern adjustable Stall Prevention Level 20 200 setting of Rated Current Operating Characteristics Keypad Setting by 4 v keys or V R Frequency Setting External Signal Potentiometer 5KQ 0 5W DC 0 10V input impedance 47KQ 4 20mA output impedance 2500 multi function inputs1 to 3 3steps JOG UP DOWN command communication setting Operation Setting Keypad Setting by RUN

Download Pdf Manuals

image

Related Search

DELTA VFD L sorozat delta vfd-el delta vfd-l delta vfd ve manual delta vfd-dd delta force teljes film magyarul delta vfd el manual delta vfd soft 1.58 delta vfd e series vfd soft delta download delta el series vfd manual delta vfd el manual pdf delta vfd software download

Related Contents

Produktkatalog clino Systeme 21  Tour à bois avec copieur KD  Cables Direct IEEE 1284 10m  Posiflex CD-2860U-B bar code reader  Sony XM-752EQX Operating Instructions  Einbauanleitung Installation Manual Mercedes M  procedimiento normalizado para incluir/excluir/cambiar productos  User manual - ArtFox Lighting  User Manual  tion est expressément fabriqué pour sa récupération en tant que  