Home

User Manual - Affordable Scales & Balances

image

Contents

1. ASS BU BLY aT NUT CHEK LINK Figure 2 Field Test Scale Components The Field Test Scale is equipped with a universal beam graduated in both avoirdupois A and metric B calibrations The appropriate scale to be used is determined by the attachment weight calibration avoirdupois or metric T 0 2 3 4 5 6 7 8 9 10 LB o 50 100 150 200 250 300 350 400 450 500 GRAM Figure 3 Beam Graduations 3 UNPACKING Carefully unpack the Field Test Scale as follows 1 2 Refer to Figures 4 5 and 6 Remove attachment weight hanger C Remove insert D Remove insert E which surrounds the base Remove insert F which contains the beam assembly Remove box H containing attachment weights Remove scale base I Finally lift the bottom insert and re move the scale pan ASSEMBLING THE FIELD TEST SCALE Refer to Figure 7 when assembling the Field Test Scale 1 Remove screws from bearing covers and slip covers off center post N NOTE Be careful not to lose screws covers and thrust plates 2 Remove tape from loop J and remove pin Save the pin T gt gt Figure 7 Base Assembly 3 Hold beam assembly O in position shown in Figure 7 and lower loop J through the hole in the base Be sure loop stop k swings under base stop L i and then lower beam assembly so g THRUST PLATE that fulcrum pivots M rest in center ort post 4 Position the black thrust plates in the ce
2. Ohaus Corporation 29 Hanover Road Florham Park NJ OHAUS 07932 0900 FIELD TEST SCALE Models 2400 11 and 2400 12 Instruction Manual INTRODUCTION This manual covers Installation and Operation for the Ohaus Field Test Scale Models 2400 11 and 2400 12 DESCRIPTION The Field Test Scale is a very compact design and provides accurate weighings of a wide variety of heavy materials even under the most adverse conditions Applications include road constructions sites weighing of soil samples archaeological samples and mineral samples The Field Test Scale is ruggedly built and designed for field applications where accurate measurements must be made The large stabilized pan will hold oversized samples without tipping and the weighted base keeps the entire scale rock steady Model 2400 11 permits readings up to 500 g taken from a single sliding weight beam with a readability of 5g A set of slotted weights stored in the base extend the capacity up to 16 kg Model 2400 12 has a capacity of 36 Ib with a readability of 0 01 Ib Figure 1 Field Test Scale with Slotted Weight Set SCALE COMPONENTS Figure 2 illustrates the various components of the Field Test Scale Refer to this figure when assembling the scale after unpacking FLAT FORM ASS MELY er Ue seo PLATFORM STUD cc oo eee o BEAM LEW ER ASS BW BL COM FEMS A TIOM B ee ASSEMELT ER 4 a re WEIGHT HANGER ASSEMELTT SEE GENTER POST
3. embly 2428 00 Pin P6113 05 Check Link 2404 00 SERVICE INFORMATION For Service assistance in the United States please call Ohaus Corporation toll free at 800 526 0659 An Ohaus Product Service Specialist will be available to help you Vl OHAUS LIMITED WARRANTY Ohaus products are warranted against defects in materials and workmanship from the date of delivery through the duration of the warranty period During the warranty period Ohaus will repair or atits option replace any component s that proves to be defective at no charge provided that the product is returned freight prepaid to Ohaus This warranty does not apply if the product has been damaged by accident or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other than Ohaus In lieu of a properly returned warranty registration card the warranty period shall begin on the date of shipment to the authorized dealer No other express or implied warranty is given by Ohaus Corporation Ohaus Corporation shall not be liable for any consequential damages As warranty legislation differs from state to state and country to country please contact Ohaus or your local Ohaus dealer for further details Ohaus Corporation 29 Hanover Road Florham Park NJ 07932 USA Tel 973 377 9000 Fax 973 593 0359 With offices worldwide P N 2402 01 R1095 Ohaus Corpo
4. he beam to oscillate between the stops If the item being weighed exceeds the beam capacity add sufficient slotted attachment weights to cause the end of the beam to move down Then slide the poise back on the beam until abalanced condition is achieved The weight is the value of the total accumulation of attachment weights plus the value read from the position of the poise on the beam TRANSPORTING THE SCALE The Field Test Scale is portable and can be moved from place to place without damage A handle has been provided in the back edge of the base When transporting the scale pick it up by the handle not by the scale beam ot the platform pan assembly Be sure to remove the attachment weights and the attachment weight hanger before picking up the scale CARE AND MAINTENANCE With reasonable care your Field Test Scale can be kept in good working order 1 Avoid severe impacts to the platform or the beam 2 Keep the scale clean Foreign material should not be permitted to accumulate in the pivot and bearing areas 3 Never apply oil or any lubricant to the pivots or bearings REPLACEMENT PARTS Part No 500 Gram Slotted Attachment Weight 2420 20 1 Kg Slotted Attachment Weight 2241 21 2 Kg Slotted Attachment Weight 2240 20 5 Kg Slotted Attachment Weight 2239 20 1 Lb Slotted Attachment Weight 2421 20 2 Lb Slotted Attachment Weight 2237 21 5 Lb Slotted Attachment Weight 2422 20 10 Lb Slotted Attachment Weight 2235 20 Weight Hanger Ass
5. nter post slots as shown in Figure Figure 8 Bearing Covers 8 5 Slip the bearing covers back into place over center post N Q 6 Replace screws and tighten in place 7 Screw on scale plate 8 Now carefully invert the scale as shown in Figure 9 Figure 9 Scale Inverted ASSEMBLING THE FIELD TEST SCALE Conr 9 10 11 12 Swing check line P into slot in loop and replace pin Q NOTE Be sure pin also goes through the hole in the check link Use a screwdriver to bend over pin Q which projects from loop NOTE Position screwdriver as shown and hit firmly with hand to bend pin Return scale to upright position Place attachment weight hanger in loop and weights on weight rack as shown in Figure 10 The Field Test Scale is now ready for use and should look like Figure 10 Figure 10 Assembled Field Test Scale WEIGHING 1 Set the scale on a reasonably level surface The level condition is not critical however it should not be obviously badly out of level The scale is in balance when the beam oscillates between the limiting stops Adjust the zero balance before beginning to use the scale so that the beam will oscillate in that manner that is with the poise set to the left side of the beam For adjustments to zero the scale turn the balance compensation weights on the left end of the beam knurned nuts To weigh place the object on the pan slide the poise on the beam to a position to cause t
6. ration 1995 all rights reserved

Download Pdf Manuals

image

Related Search

User Manual Affordable Scales manual scales for weight affordable scales and balances buy affordable scale online how to use a manual scale download free manual of scale scales for home use digital scales for home cheap scales for sale professional scales for sale portable scales for sale best affordable weight scale portable scales for small business a and a scales llc manual personal scales at amazon accurate weight scales for home scales for sale amazon how to use a manual weight scale portable weight scales for people portable digital scales amazon doctor scales for home medical scales for home use where to buy small digital scales

Related Contents

Pelco SARIX C2951M-C User's Manual  Petra TA 15 toaster  Desg2 GB-FR-NL-ES-D-PT-IT  Capítulo 7 - Raymarine  iRobot B380020 Use and Care Manual  MT300 DIN - Diel - Eletronics Devices  Belgacom Maestro™ 2035  View PDF User Guide - LIDA. Laalou Industries Domestic Appliances  NOTA  Slot Machine User Manual  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.