Home

DataLynx User Manual

image

Contents

1. 26 Diagnostics One Dial Test Allows the user to perform a trial dial up and poll to confirm that the configuration will work Poll Interval Timed Interval allows the user to specify the poll to occur at specific timed intervals Note If you have multiple phone numbers each poll will dial each of the phone numbers at the poll interval In contrast if each phone number had an individual poll interval there eventually would be a conflict in poll times Day Interval Allows the user to specify the poll to occur at certain days and times Fields User entered fields that DataLynx will request when polling DataLynx User Manual 5 2 2 Modifying a Modem To modify a modem go to menu Options gt Configure Server S DataLynx Monitor TRIAL VERSION File Tools Options Help Server ddr Configure Server la r Stop Polling sennasnannacs A list of modems if any configured for the Server will appear Server Configuration Server Configuration Modem s My Modem Modify View Delete Duplicate 27 DataLynx User Manual Click on the Modify View button and a Modem Configuration screen will appear with the PLC data The Modem Configuration window below is an example Modem Configuration Modem Configuration Text Files Database Modem Settings Alias My Modem Baud Rate 3600 xl Retries E COM Port Coma Browse Parity None
2. Phone Number Add Delete 1112222 Data Files Pall Intern eee Phone Number 1112222 C Timed Interval Every HH 00 MM o0 Data Directory C My Data Prowse Daylnterval SM MT TD Wl Th Fl s Alias Optional gt Bete HE 12 EMO Fields Use Alias in Filename ada Alias Address Type Attibutes 1 New Data File Cycle pay i Water Level 40004 Integer Field S iar Temperat 40010 Float F ela Separation comma Edit PatNum 40100 ASC Length4 Log Phone Number r Delete Display header for fields Uses field alias for header label D Log Time Stamp in Data Files Example Filename 1112222Jan 1 2003 csv Archiving and Deleting Archive Files Cycle Never Archived Files Directory Browse Delete Files Cycle Never Modbus RTU Diagnostics ti One Dial Test o iS E Modbus ATU DirectLogie Memoty iL Cancel Once finished making changes click the OK button or Cancel to discard your changes 28 DataLynx User Manual 5 2 3 Deleting To delete modems go DataLynx Monitor TRIAL ERSION to menu Options File Tools Options Help gt Configure Server server ad MEE Stop Polling Shut Down Server A list of modems if any configured for the Server will appear Server Configuration Server Configuration COM Port My Modem Modify View ea Delete Es gt D
3. Automationdirect com nos esforzamos constantemente para mejorar nuestros productos y servicios as que nos reservamos el derecho de hacer cambios al producto y o a las publicaciones en cualquier momento sin notificaci n y sin ninguna obligaci n Esta publicaci n tambi n puede discutir caracter sticas que no est n disponibles en ciertas revisiones del producto Marcas Registradas Esta publicaci n puede contener referencias a productos producidos y u ofrecidos por otras compa as Los nombres de las compa as y productos pueden tener marcas registradas y son propiedad nica de sus respectivos due os Automationdirect com renuncia cualquier inter s propietario en las marcas y nombres de otros Propiedad Literaria 2004 Automationdirect com Incorporated Todos los derechos reservados No se permite copiar reproducir o transmitir de ninguna forma ninguna parte de este manual sin previo consentimiento por escrito de Automationdirect comI M Incorprated Automationdirect com TM retiene los derechos exclusivos a toda la informaci n incluida en este documento Los usuarios de este equipo pueden copiar este documento solamente para instalar configurar y mantener el equipo correspondiente Puede ser usado tambi n para prop sitos de educaci n en institutos de ense anza DataLynx User Manual AUTOMATIONDIRECT COM END USER LICENSE AGREEMENT AND LIMITED WARRANTY The software accompanying this license agreement the Soft
4. Koehaa aait ci FA Indusoft Web Studio v6 0 0 Turn Off Computer E Infragistics stat G B A 1010 HA mputPro Click on the Uninstall button and this window should appear File Help gt T TOSHIBA gt 7 TOSHIBA Applications fm Visual Reports gt War FTP Daemon Sener Bla WAAREDIRECT IP Address 192 166 0 50 Status Mot installed 21 DataLynx User Manual 5 2 Monitor 22 Overview The DataLynx Monitor allows the user to configure the DataLynx Server and retrieve its data files over the network Also the DataLynx Monitor permits the user to troubleshoot Below is the main screen and the explanations of each field E Datal ynx Monitor TRIAL ERSION El File Tools Options Help Modem s COM Font My Modern Server Address Status Scheduled 9 12 2004 31742004 9 49 53 AM gt Last Update Status Unlocked Lock Polling Modems Stop Polling Messages Connected to Server Server Address Field where one enters the address of the DataLynx Server Last Update Denotes the most recent PLC input time Status Displays the Server s locked and listening state Modem s Displays list of currently configured modems on the Server as well as each modem s status Note Modems only lists the last update Check the date to verify if you are receiving information when expected Messages Displays updates from the Server as well as from
5. Modbus Serial must be supported on the PLC When configuring DataLynx on what addresses to read please take care in converting the modbus address into the PLC s native memory addressing scheme 4 1 Testing Modem Configuration 12 To aid in configuring and troubleshooting the modem connections use Hyperterminal and manually connect to the PLC s modem from the PC s modem The PLC does NOT need to be connected to the modem This test confirms that the modems can communicate with each other To run the test complete the following steps 1 Start Hyperterminal by going to Start gt Program Files gt Accessories gt Communications gt Hyperterminal 2 In Hyperterminal the user will be prompted for a session name enter the desired session name e g Test Modem 3 Next the user will be prompted for the connection settings select the PC modem s COM Port and configure the necessary settings 4 Click OK 5 To confirm that the modem is working enter AT An OK message should appear from Hyperterminal DataLynx User Manual 6 If the OK appears test the dialing by entering ATDTYYYY where YYYY is the phone number a Ex ATDT2555678 to dial 255 5678 7 Depending on the modem connection and the phone line it may take a few minutes before receiving feedback a If successful Connected XXXXX bps where XXXXX is the baud rate should appear b If not successful an error like one
6. of the following will be received BUSY NO DIALTONE NO CARRIER etc 4 2 Example Setup for AutomationDirect PLCs The information below illustrates the configuration used for testing DataLynx PLC DL05 Modem for PLC MDM TEL Modem See the MDM TEL setup wizard for configuration information Modem for PC Toshiba Software Modem DLO5 PLC configured with the following 1 Port 2 Setup a Modbus Serial b Parity 0 zero 2 Modem Connected to Port 2 13 DataLynx User Manual 5 0 DataLynx PLC 5 1 Server Overview The DataLynx Server s primary function involves dialing up to PLC s and recording the data into text files in the format specified by the user The format of the text file is set with the DataLynx Monitor For more information on configuring the Server with the Monitor refer to the Monitor section 5 1 1 Installing Service The DataLynx Server needs to be installed and run in order to run without user intervention Doing so is a simple process Go to Start Button gt Program Files gt DataLynx gt DataLynx Server J E Documentation gt 12 Documents FreeSMTP Net DataLynx Monitor Y Settings Games 4 2 Search gt an Ghost Installer Studio gt 22 Uninstall DataLynx 9 Help and Support a HP gt a TeamWave Workplace 2 Run HTML Help Workshop T TeeChart Pro v6 Active 7 InduSoft Web Studio 5 1 Log OFF Jkulakowski fm Indusoft Web Studio
7. the Monitor itself DataLynx User Manual 5 2 1 Configuring Note The Server must be connected in order to configure the Server Co w the men DataLynx Monitor TRIAL YERSION Options gt Configure File Tools Options Help Server Server Addr Stop Polling Shut Down Server A list of modems if any configured for the Server will appear ED Server Configuration Server Configuration Modem s COM Pot COM1 My Modem Modify View Delete pj Dupicate OK Cancel 23 DataLynx User Manual To add a modem click on the Add button and a Modem Configuration screen like the following will appear FF Modem Configuration E ES Modem Configuration TextFiles Database Modem Settings Alias Baud Rate 9600 T Beties 3 COM Port COM Browse Parity None r Phone Number Add Delete 1081 Po 3 an ayal Every HH oo AM foo y Browse DayInteval ST MEU TT WP tht FR sE DA Al Time HH 00 Moo lie isra ig es f mesnr f Modbus ATU DirectLogie Memory Below is an explanation of each of the Modems Configuration Window s fields Alias Optionally a more descriptive name for the modem e g My PC s Modem COM Port The port the modem will use Baud Rate The speed that the modem will connect at Parity Parity that the modem will use none is the default p
8. v6 0 10 Turn Off Computer GF Infragistics stat G B A oO HA muero 14 Us N A CNE CV M TOSHIBA 7 TOSHIBA Applications T Visual Reports Van War FTP Daemon Click the Install button This window should appear showing Status as Installed Stopped Note This does not start the DataLynx Server To start the Server refer to the Running Service section DataLynx User Manual File Help Server EL RE CIRECT IF Address 192 168 0 50 Status Mot installed Start Continue E Pause Stop Polling 2 DataLynx Server Trial File Help Server BlAWwARE DIRECT IP Address 192 766 0 50 Status Installed Stopped gt Start Continue E Pause Stop Folling J Stop m Uninstall 15 DataLynx User Manual 5 1 2 Runnin Service If you do not already have the DataLynx Server Window open go to Start Button gt Program Files gt DataLynx gt DataLynx Server Documentation 2 Documents p FreesMTP Net gt DataLynx Monitor D gt settings y Genes i 2 Search gt Ghost Installer Studio gt 22 Uninstall DataLynx Help and Support HP E Run HTML Help Workshop TeeChart Pro v6 Active 7 InduSoft Web Studio 5 1 Log OFT Jkulakowsid 7 Indusoft Web Studio v6 0 10 Turn Off Computer GA Infragistics Psat O BS oO SY H amp S Input ero M TOSHIBA 7 TOSHIBA Applications Visual Repo
9. DataLynx Version 1 3 User Manual WAUTOMATIONDIRECT A product of www bizwaredirect com DataLynx User Manual M WARNING y Thank you for purchasing automation equipment from Automationdirect com doing business as AutomationDirect We want your new automation equipment to operate safely Anyone who installs or uses this equipment should read this publication and any other relevant publications before installing or operating the equipment To minimize the risk of potential safety problems you should follow all applicable local and national codes that regulate the installation and operation of your equipment These codes vary from area to area and usually change with time It is your responsibility to determine which codes should be followed and to verify that the equipment installation and operation is in compliance with the latest revision of these codes At a minimum you should follow all applicable sections of the National Fire Code National Electrical Code and the codes of the National Electrical Manufacturer s Association NEMA There may be local regulatory or government offices that can also help determine which codes and standards are necessary for safe installation and operation Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards We do not guarantee the products described in this publication are suitable for your particular applicatio
10. Disconnect Server Address lecahost E 31 DataLynx User Manual 5 2 6 Hiding 32 Hiding is a convenient feature for temporarily placing the Monitor out of view for later access To hide the Monitor go to the menu File gt Hide 6 DataLynx Monitor File Tools Options Help Exit Notice that the DataLynx icon appears on the task bar Conversely the application may be restored by right clicking on the icon and selecting the Restore item Les A i DataLynx User Manual 5 2 7 Backing Up and Restoring Backing Up Backing up the configuration allows the user to safely restore all changes in the event of a hardware failure To back up the configuration go to the menu Tools gt Backup Configuration File Tools Options Help Report Restore Configuration Lack Server You will be prompted for a filename Click Save and note where you saved the file for a possible future restoration Restoring To restore the configuration go to the menu Tools gt Restore Configuration The following window should appear SH DataLynx Monitor File Tools Options Help Report Restore Configuration Backup Configuration Lock Serwer You will be prompted for a filename Click Open and the Server Monitor should be restored to its original state 33 DataLynx User Manual 5 2 8 Polling 34 The DataLynx Server maintains polling and not polling states for PLC inp
11. TY for DataLynx The software accompanying this license agreement the Software is the property of AutomationDirect cor or its suppliers and is protected by United States and International Copynght laws and International treaty provisions No ownership nights are granted by this Agreement or possession of the Software Therefore you must treat the Licensed Software like any other copyrighted material 8 9 a book or musical recording except that you may make single copy for backup or archival purposes Your nights and obligations in its use ate described as follows D Yes agree with all the terms of this license agreement lt Back Hent Cancel DataLynx User Manual After reading and understanding the license agreement check the Yes I agree with the terms of this license agreement option and click Next i DataLynx setup AS License Agreement Please read the following license agreement carefully Please closely read the following license agreement Do you accept all the terms of the following license agreement AutomationDirect com End User License E AutomationDiect com END USER LICENSE AGREEMENT AND LIMITED WARRANTY for Datalynx The software accompanying this license agreement the Software is the property of AutomationDurect com or its suppliers and is protected by United States and Intemational Copyright laws and International treaty provisions No ownership rights a
12. a una instalaci n e operaci n segura Si no se siguen todos los c digos y normas aplicables puede resultar en da os al equipo o lesiones serias a personas No garantizamos los productos descritos en esta publicaci n para ser adecuados para su aplicaci n en particular ni asumimos ninguna responsabilidad por el dise o de su producto la instalaci n u Operaci n Nuestros productos no son tolerantes a fallas y no han sido dise ados fabricados o intencionados para uso o reventa como equipo de control en l nea en ambientes peligrosos que requieren una ejecuci n sin fallas tales como operaci n en instalaciones nucleares sistemas de navegaci n a rea o de comunicaci n control de trafico a reo m quinas de soporte de vida o sistemas de armamentos en las cuales la falla del producto puede resultar directamente en muerte heridas personales o da os f sicos o ambientales severos Actividades de Alto Riesgo Automationdirect com espec ficamente rechaza cualquier garant a ya sea expresada o implicada para actividades de alto riesgo Para informaci n adicional acerca de garant a e informaci n de seguridad vea la secci n de T rminos y Condiciones de nuestro catalogo Si tiene alguna pregunta sobre instalaci n u operaci n de este equipo o si necesita informaci n adicional por favor ll menos al n mero 770 844 4200 en Estados Unidos Esta publicaci n est basada en la informaci n disponible al momento de impresi n En
13. and which is returned to AutomationDirect com within the warranty period This shall be the sole and exclusive obligation of AutomationDirect com and your sole and exclusive remedy with respect to any such failure The Limited Warranty is void if failure of the Software or component has resulted from accident abuse or misapplication Trademarks Microsoft and Microsoft Excel are registered trademarks Windows is a trademark of Microsoft Corporation DataLynx User Manual Document History Si7WARE Improving Automation Through nnana tkn DataLynx User Manual PC DLYNX M Please include the manual number and the manual issue both shown below when communicating with Technical Support regarding this publication Manual Number PC DLYNX M Issue First Edition Issue Date October 2004 Publication History Date Description of Changes WAUTOMATIONDIRECT VI DataLynx User Manual Table of Contents TO Tint OC m a o A E 20 mstallation Ok aval tropa 2 D SO E E E 9 4 0 Modem Connectivity ssssesesssessesesssseesssssseressssrresssssseeesss 12 4 1 Testing Modem Configuration 12 4 2 Example Setup for AutomationDirect PLCs 13 OR ea 14 SR E 14 dl SAIS Sie get 14 id UI SEO cts 16 A Un IA 7 SO ere err er 18 peg AOS ideas 19 5 1 6 Uninstalling mn 21 OO o 22 PAED ON EE E T 23 SA a Modes 27 DE eonads 23 O eee 30 72 A e 31 OC PORC PO NOR o e 32 5 2 7 Bac
14. arity and is preferred for most modems Retries Number of times DataLynx will try to read data before it reports an error 24 DataLynx User Manual Below is an explanation of each of the Phone Numbers Configuration fields Phone Number The phone number DataLynx is to dial Data Directory Where the data files will be stored Alias Optional a more descriptive name of the phone number e g Plant One in Atlanta Use Alias in Filename Configures DataLynx to use the alias in the data logged file name New Data file Cycle Configures Datalynxs new file creation cycle Field Separation Configures either tab or comma to be used in separating individual fields Log Phone Number Configures DataLynx to log the phone number in the data file Log Alias Configures DataLynx to log the alias in the data file Display header for fields Configures DataLynx to log the headers in the first line of the data file Log Timestamp in Data Files Configures DataLynx to log the date and time in the data file Example Filename Illustrates an example file name given the current configuration Archiving and Deleting Archive Files Cycle Configures DataLynx to archive monthly yearly Archives by zipping files into a zip file Archived Files Directory Where the zipped files will be stored Delete Files Cycle How often DataLynx will delete the files Modbus Station the station configured in the PLC 25 DataLynx User Manual
15. art Continue L Pause Stop Polling E Stop Uninstall 17 DataLynx User Manual Click the Pause Stop Listening button and this window should appear Note This does not stop the Datalynx Server To stop the Server refer to the Stopping section 5 1 4 Stopping 63 DataLynx Server Trial xX Bl AREDIRECT IP Address 192 7165 0 50 gt Start Continue L i Pause Stop Folling al Stop El Uninstall Stopping the DataLynx Server completely stops the program instead of stopping polling This feature is useful because the Server must stop before you can uninstall it If you do not already have the DataLynx Server Window open go to Start Button gt Program Files gt DataLynx gt DataLynx Server ES Documents al FreeSMTP Net CP Settings gt a Games 2 Search gt an Ghost Installer Studio 2 Help and Support an HP E Run HTML Help Workshop M InduSoft Web Studio 5 1 Log Off Jkulakowski 7 Indusoft Web Studio v6 0 0 Turn Off Computer FF Infragistics stat G B lo 5 mput Pro 18 DataLynx a Documentation gt 5 Datalynx Monitor A DataLynx Server gt 22 Uninstall DataLynx T TeamWave Workplace I TeeChart Pro v6 Active E TOSHIBA FA TOSHIBA Applications Visual Reports em War FTP Daemon Y Y Y Y NN P DataLynx User Manual In the DataLynx Server 47 Datal ynx Server Trial F
16. ation has been entered correctly the assigned key will appear DataLynx Registration Form Serial Number From DVD Case 00000185 Key From DataLynx Install B XHAPERSXAC 102 QTY UQE Create Registration Your assigned key B XHAPERSXAD 103 QTYUOE Found registration for 1 device s Copy the assigned key and paste into the DataLynx Monitor Registration screen by pressing the right mouse button and selecting Paste fe Registration Serial Number a OO Key Level Trial Numberand 5 fields Cut MumberPh Copy OK red 1 e Click the Register button Registration Six Serial Number i i o Key B XHAPERSHAC 1 O2 QTYUOE Level Trial Only 1 Phone Number and 5 fields Number Phone s authorized 1 OK Cancel DataLynx User Manual A success message and the registration window will show registration status Registration x Successfully registered e Click OK 11 DataLynx User Manual 4 0 Modem Connectivity To ensure successful communication at least two modems are required One modem is needed for the PLC and one modem is needed for the PC Each PLC brand typically has a different set of requirements and procedures Generally an ideal modem would support parity and a baud rate of at least 56K to ensure fast and reliable connections Please refer to the PLC s documentation on configuring modem connectivity with the PLC
17. er stopped 9 3 2004 5 21 24 PM Server stopped 9 3 2004 5 23 30 PM Server stopped 9 4 2004 11 15 14 AM Server stopped 9 4 2004 11 56 53 AM Server stopped 9 4 2004 12 28 16 PM Server started 9 4 2004 12 29 27 PM Server stopped 9 4 2004 12 36 42 PM Server started 9 6 2004 8 59 53 4M 9 6 2004 6 59 53 AM Foll Error 918876206 Cannot connect 9 6 2004 9 04 52 4M 9 6 2004 9 04 52 4M Poll Error 918876206 Cannot connect 9 6 2004 9 08 35 AM 9 6 2004 9 08 35 AM Tried to start polling while it is not stopped 9 6 2004 9 13 38 4M 9 6 2004 9 73 38 4M Pall Error 918876206 Cannot connect 9 6 2004 3 18 07 AM Server stopped 9 6 2004 9 20 27 AM Server started 9 6 2004 9 22 59 4M Server stopped 9 6 2004 9 25 59 AM Server started 9 6 2004 9 26 38 AM Server stopped 9 6 2004 9 55 34 AM Server started 9 6 2004 3 32 19 PM Server stopped 9 7 2004 8 32 40 AM Server started 9 7 2004 9 37 37 AM Server stopped 20 5 1 6 Uninstalling DataLynx User Manual For troubleshooting reasons it is a good idea to uninstall the Server entirely To open the DataLynx Server Window go to Start Button gt Program Files gt DataLynx gt DataLynx Server E Documentation Fe Documents 3 FreesMTP Met DataLynx Monitor 2 Search gt a Ghost Installer Studio gt ID Uninstall Datalynx S Help and Support HP gt itt E Run HTML Help Workshop gt TeeChart Pro v6 Active 7 InduSoft Web Studio 5 1
18. hat the Software will be error free that it will satisfy your planned applications or that all defects in the Software can be corrected DataLynx User Manual If AutomationDirect com provides information or assistance regarding the use of the Software or otherwise AutomationDirect com is not assuming the role of engineering consultant AutomationDirect com disclaims responsibility for any errors or omissions arising in connection with engineering in which its Software or such information or assistance is used The foregoing is the sole and exclusive warranty offered by AutomationDirect com AutomationDirect com disclaims all other warranties express or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose with regard to the licensed software and all accompanying materials In no event shall AutomationDirect com be liable for incidental or consequential damages including lost profit lost savings lost opportunities or other incidental or consequential damages arising out of the use or inability to use the licensed software even if AutomationDirect com has been advised of the possibility of such damages AutomationDirect com s entire liability shall be at AutomationDirect com s option either a return of the price paid for the Software or component or b repair or replacement of the Software or component that does not meet AutomationDirect com s Limited Warranty
19. ile Open With prompts you for the application in which to open the file Note If you open the current log file outside of DataLynx Example log file straight from Excel it will lock the file and not allow DataLynx to store data 37 DataLynx User Manual 6 0 Troubleshooting Miscellaneous Cannot Connect to Server Double check the Server Address it may not be correct Verify that the Server and Monitor computers are online and can access network facilities such as e mail and Internet Ensure that cables are connected Verify that computers can access the Internet by going to a test web site such as www yahoo com Invalid COM Port Error Confirm that the COM Port is correct for the modem Poll Keeps Failing Error Reading Data Confirm that modbus serial is enabled on the PLC Confirm that modem is properly configured to communicate with the PLC Poll Is Not Occurring at Specific Intervals Because the dialing and polling usually takes more than one minute the timed intervals may not occur at the correct time Try extending the poll intervals to ensure that they will occur on more reliable intervals 30
20. ile Hel Window click the Stop Server ElZWBREDIRECT button and this window h ld appear IP Address 1921660 50 snou Status Installed Stopped 5 1 5 Diagnosing Diagnosing the Datalynx Server allows the user to troubleshoot and view real time events If the DataLynx Server Window is not open go to Start Button gt Program Files gt DataLynx gt DataLynx Server fm Datalynx 7 Documentation Ed Documents i FreesMTP Met gt 5 DataLynx Monitor eS Settings an Sollee J Search gt em Ghost Installer Studio gt 22 Uninstall Datalynx Help and Support E He l 2 Run 7 HTML Help Workshop gt TeeChart Pro v6 Active A InduSoft Web Studio 5 1 gt 7 TOSHIBA o Indusoft Web Studio v6 0 gt TOSHIBA Applications 9 Turn Off Computer Infragistics gt fr Visual Reports de Start E e 5 hz Input Pro gt War FTP Daemon 19 DataLynx User Manual In the DataLynx Server Window go to the menu File gt Error Log io DataLynx Server Trial File Help Hide AREDIRECT The Diagnostics Window below should appear Error Log Log Entries 21922004 6 53 47 AM Server started 0312004 6 50 34 4M Server stopped 8312004 8 51 33 AM Server stopped 8312004 9 55 23 AM Server stopped 9 3 2004 6 59 59 AM Server started 9 3 2004 3 43 55 PM Server stopped 9 3 2004 5 07 15 PM Server stopped 9 3 2004 5 19 38 PM Serv
21. ing Reporting is one of the most useful features of the Monitor The user may view or save files generated by the Server over a network without having physical access to the Server To view a report go to menu EPA Tools gt Report File Tools Options Help Sen Restore Configuration Backup Configuration Lock Server Le Mana A report screen like the following dialog box should appear selecta phone line and then select a file optionally you can select the modem To open afile click the Open or the Open With button To save the file to this computer click the Save button p Filels Modem My Modem COM1 x 36 DataLynx User Manual Select the desired PLC data you wish to view in the modem phone number list 101 x Report selecta phone line and then select a file optionally you can select the modem To open afile click the Open or the Open With button To save the file to this computer click the Save button m File s Modem My Modem COM1 era ot 2004 cev Phone Line s 9188762064January 02 2004 cs 9188762064 anuary 03 2004 ce 318876206 September 06 2004 ce Close Tu Now select a file in the File s list and click either the Open Open With or the Save button There is a difference between the Open and Open With buttons Open uses the default application to open the f
22. ion Version install Demo your CD drive Then click on Configure our EZTouch industrial touch panels for PLC based systems cc 2 OK and the program will A O E start Use our 32 bit OPC DDE Server to monitor and fine tune your PLC process from your favorite Windows application Click on DataLynx DataLynx User Manual To start the installer program click Next if DataLynx setup Welcome to the Installation Wizard This wizard wall guide you through the entre DataLyr installation Welcome to the DataLyre Setup program This program will install Datal ynx on pour computer t is strongly recommended that you exit all Windows programs before running this Setup program Click Cancel to quit Setup and close any programs you have running Click Next to continue with the Setup program WARNING This program ts protected by copyright law and international treaties Unauthorized reproduction or distribution of this program or ary portion of it may result in severe civil and criminal penalties and will be prosecuted to the maximum extent possible under law 2 DataLynx setup License Agreement Please read the following license agreement carefully Please closely read the following license agreement Do you accept all the terms of the following license agreement AutomationDirect com End User License AutomationDirect com END USER LICENSE AGREEMENT AND LIMITED WARRAN
23. ion if only one computer is available b If hosting the Server and Monitor on different computers users may install both the Server and Monitor on the Server for quick installing and configuring 2 Server and Monitor on Different Computers a Ideal when the physical location of the Server is not easily accessible b Must note the IP Address or name of the Server DataLynx software is available on the AutomationDirect Product Showcase CD To install DataLynx insert the AutomationDirect CD into your PC s CD drive The CD should start automatically and open the installation window shown below O Macromedia Fash Players A No te File View Control Help gt DirectSOFT32 Programming install Demo If the AutomationDirect CD Program amp Document all DirectLOGIC PLC s as well as favorites from TI Siemens GE and Koyo does not start automatically go LookoutDirect PC HMI install Demo TM to your Windows START Object oriented event driven HMI software from AutomationDirect National Instruments amp Host Engineering button select RUN and type KEPDirect Data Servers install Demo s Connect your HMI SCADA MES or ERP OPC client software to E setup IEA DL PLCs and Ethernet 1 0 on DL205 405 or Terminator 1 0 O instali PLC Demo Change the letter E to DataWorx Data Logging install WinPL C Demo Log PLC data from ECOM S to networked PC s as text files correspond to the letter for EZTouch Evaluat
24. king Up and Res One 33 Dic POU a E e 34 3 2 9 Locking Unlocking sesesiosiesrymiseissyrnis 35 NA A ness 36 6 0 Troubleshooting Miscellaneous ooooococnnonccccnnncccnonnccnnnnnss 38 DataLynx User Manual DataLynx User Manual 1 0 Introduction DataLynx provides an easy and inexpensive way to collect data from your PLCs The DataLynx Server stores the information it gathers onto your PC into either a comma or tab delimited text file s These files can be created on a daily monthly or yearly basis The data can be opened in Excel NotePad or a program of your choice At this point you can save the files or print the data DataLynx is unique in that it uses a phone line and modems compared to more expensive ethernet lines It is ideal for long distances where the location is not easily accessible and not economical to visit the PLC and retrieve data System Requirements Hardware Required Pentium II with 128 megabytes of ram and 10 megabytes of hard disk space free PLC which supports Modbus serial Modems for PLC and PC Software Required The Server can run on Windows NT SP5 or higher 2000 or XP The Monitor can run on Windows 98 NT 2000 or XP DataLynx User Manual 2 0 Installation of DataLynx Before you start ensure that the PLC s and Server Monitor computer s are connected to the network Decide what type of installation you want 1 Server and Monitor on Same Computer a May be the only opt
25. mMC nie toute garantie expresse ou implicite d aptitude l emploi en ce qui a trait aux activit s risque lev Pour des renseignements additionnels touchant la garantie et la s curit veuillez consulter la section Modalit s et conditions de notre documentation Si vous avez des questions au sujet de l installation ou du fonctionnement de cet quipement ou encore si vous avez besoin de renseignements suppl mentaires n h sitez pas nous t l phoner au 770 844 4200 Cette publication s appuie sur l information qui tait disponible au moment de l impression la soci t Automationdirect com nous nous effor ons constamment d am liorer nos produits et services C est pourquoi nous nous r servons le droit d apporter des modifications aux produits ou aux publications en tout temps sans pr avis ni quelque obligation que ce soit La pr sente publication peut aussi porter sur des caract ristiques susceptibles de ne pas tre offertes dans certaines versions r vis es du produit Marques de commerce La pr sente publication peut contenir des r f rences des produits fabriqu s ou offerts par d autres entreprises Les d signations des produits et des entreprises peuvent tre des marques de commerce et appartiennent exclusivement leurs propri taires respectifs Automationdirect comMC nie tout int r t dans les autres marques et d signations Copyright 2004 Automationdirect com Incorporated Tous droits r serv
26. mpt for the setup type will appear There are three types Monitor Server and Server and Monitor Ifa type in the list is selected a description of the type will appear on the right hand side labeled Description 2 DataLynx setup x E Setup Type Select the setup type of the application M Description Monitor Installs both the DataLyns Server and Monitor Recommended if this computer is the only one available for data collection Server Server and Morutor Back Next gt Cancel DataLynx User Manual After it is determined which type of setup is wanted click Next and a prompt to save the DataLynx files will appear By default the files will save into c Program Files DataLynx but the location of the DataLynx files can be changed by clicking on the Browse button E Destination Folder Click Next to install the application to this folder or click Browse to install to a different location Select the destination folder where you want to install Datal yn To install to a different location click Browse and select another folder Installation folder C Program Files Datalunx Browse Space required on pour hard disk 11 35 MB available 22 31 GB After the location of the files has been determined click Next and a prompt for the program group will appear By default the program group is DataLynx but the program group may be changed by en
27. n nor do we assume any responsibility for your product design installation or operation Our products are not fault tolerant and are not designed manufactured or intended for use or resale as on line control equipment in hazardous environments requiring fail safe performance such as in the operation of nuclear facilities aircraft navigation or communication systems air traffic control direct life support machines or weapons systems in which the failure of the product could lead directly to death personal injury or severe physical or environmental damage High Risk Activities Automation Direct specifically disclaims any expressed or implied warranty of fitness for High Risk Activities For additional warranty and safety information see the Terms and Conditions section of our catalog If you have any questions concerning the installation or operation of this equipment or if you need additional information please call us at 770 844 4200 This publication is based on information that was available at the time it was printed At AutomationDirect we constantly strive to improve our products and services so we reserve the right to make changes to the products and or publications at any time without notice and without any obligation This publication may also discuss features that may not be available in certain revisions of the product This publication may contain references to products produced and or offered by other companies The p
28. pped by clicking the Cancel button After the install is complete a notification will appear to confirm that installation has been successful Click Finish to exit the DataLynx installer Installation Complete The Installation Wizard has successfully installed Datal yr Datalynx has been successtully installed Press the Finish button to exit Setup program DataLynx User Manual 3 0 Registration Registration Instructions e Ensure that the Server is running e Start the Monitor and connect to the Server e Go to Help gt Registration 3 DataLynx Monitor TRIAL VERSION File Tools Options Help m Modems Contents Server Error Log About Server ddress Last Update In the registration window copy the registration key by selecting the key pressing the right mouse button and selecting Copy fE Registration e Number and 5 fields lorized 1 E Ci Fi Y Delete With your browser go to the following web site http www bizwaredirect com datalynxregistration aspx and paste the registration key into the Key field in the web form Also enter the serial number which is located on the back of the CD cover and the order number DataLynx Registration Form serial Number From DVD Case Key From DataLynx Install Create Registration DataLynx User Manual 10 Click the Create Registration button If the inform
29. re granted by this Agreement or possession of the Software Therefore vou must treat the Licensed Software like any other copyrighted material e g a book or musical recording except that you may make a single copy for backup or archival purposes Your nghts and obligations in its use are described as follows The next screen contains important readme information that may be pertinent to you After reading the Readme information click the Next button DataLynx User Manual 2 DataLynx setup F Re adme Information Please read the following information about the Datalyns carefully Important information about DataLyns Thank you for purchasing industrial control products from BizvVareDirect Inc We want your new system to operate safely Anyone who installs or uses this equipment should read the manual and any other relevant publication before installing or operating the system To minimize the risk of potential safety problems you should follow all applicable local and national codes that regulate the installation and operation of your system These include the National Fire Code National Electric Code and other codes of the National Electrical Manufacture s Association NEMA There may be local regulatory or governmental offices that can help determine which codes and standards annlw ta waur situation It ie vaur reenonesihility ta determine lt Back Cancel Next a pro
30. roduct and company names may be trademarked and are the sole property of their respective owners AutomationDirect disclaims any proprietary interest in the marks and names of others Copyright 2004 Automationdirect com Incorporated All Rights Reserved No part of this manual shall be copied reproduced or transmitted in any way without the prior written consent of Automationdirect com Incorporated AutomationDirect retains the exclusive rights to all information included in this document DataLynx User Manual N AVERTISSEMENT W Nous vous remercions d avoir achet l quipement d automatisation de Automationdirect comMC Nous tenons ce que votre nouvel quipement d automatisation fonctionne en toute s curit Toute personne qui installe ou utilise cet quipement doit lire la pr sente publication et toutes les autres publications pertinentes avant de l installer ou de l utiliser Afin de r duire au minimum le risque d ventuels probl mes de s curit vous devez respecter tous les codes locaux et nationaux applicables r gissant l installation et le fonctionnement de votre quipement Ces codes diff rent d une r gion l autre et habituellement voluent au fil du temps Il vous incombe de d terminer les codes respecter et de vous assurer que l quipement l installation et le fonctionnement sont conformes aux exigences de la version la plus r cente de ces codes Vous devez tout le moins respecter to
31. rts em War FTP Daemon AMIA LES ee Vi Va Y This window will appear i DataLynx Server Trial File Help assuming Datalynx is not A gt Server Bl tAREDIRECT installed Click the IP Address 192 168 0 50 Start Continue button Status Installed Running Note It may take a couple of tr minutes for the Server to start running 16 DataLynx User Manual 5 1 3 Pausing Pausing forces the Server to stop polling for PLC input This can be useful when configuring the Server because it will prevent irrelevant data from being stored If you do not already have the DataLynx Server Window open go to Start Button gt Program Files gt DataLynx gt DataLynx Server f Programs G Datalynx 7 Documentation 2 Documents gt fan FreeSMTP Net G DataLynx Monitor eS Settings E Eales J Search gt Ghost Installer Studio gt TD Uninstall DataLynx Help and Support an HP gt TeamWave Workplace Run em HTML Help Workshop fam TeeChart Pro v6 Active 7 InduSoft Web Studio 5 1 gt TOSHIBA Logoff AIR E Indusoft Web Studio v6 0 gt TOSHIBA Applications 0 Turn Off Computer em Infragistics fan visual Reports A Start j e SE 7 Input Pro gt War FTP Daemon This window will appear 42 DataLynx Server Trial Assuming Runnin AaS 3 5 Server Bl WAREDIRECT IF Address 192 168 0 50 Status Installed Running i St
32. s Nulle partie de ce manuel ne doit tre copi e reproduite ou transmise de quelque fa on que ce soit sans le consentement pr alable crit de la soci t Automationdirect com M Incorporated Automationdirect comTM conserve les droits exclusifs l gard de tous les renseignements contenus dans le pr sent document DataLynx User Manual M ADVERTENCIA Gracias por comprar equipo de automatizaci n de Automationdirect com Deseamos que su nuevo equipo de automatizaci n opere de manera segura Cualquier persona que instale o use este equipo debe leer esta publicaci n y cualquier otra publicaci n pertinente antes de instalar u operar el equipo Para reducir al m nimo el riesgo debido a problemas de seguridad debe seguir todos los c digos de seguridad locales o nacionales aplicables que regulan la instalaci n y operaci n de su equipo Estos c digos varian de rea en rea y usualmente cambian con el tiempo Es su responsabilidad determinar cuales c digos deben ser seguidos y verificar que el equipo instalaci n y operaci n est n en cumplimiento con la revisi n mas reciente de estos c digos Como m nimo debe seguir las secciones aplicables del C digo Nacional de Incendio C digo Nacional El ctrico y los c digos de NEMA la Asociaci n Nacional de Fabricantes El ctricos de E E U U Puede haber oficinas de normas locales o del gobierno que pueden ayudar a determinar cuales c digos y normas son necesarios par
33. tering it in the text box DataLynx User Manual Program Group Select the program group where the Installation Wizard will install application shortcuts Select program groupe Datalyns Accessones Ace Divx Player ActveServer Component ActiveState ActivePer 5 6 Administrative Tools dobe Apache HTTP Server 2 0 50 ppled Motion Products Automated Solutions Achyvex Automated Solutions OPC AutomationDirect Click Next and a prompt will appear to start the installation process It is possible to click the Back button and review the installation settings before committing to the install When satisfied with the installation settings click the Next button I Ready to Install the Program The Installation Wizard is ready to install the DataLyr ou are now ready to install Datalyns Press the Next button to begin the installation or the Back button to re enter the installation information DataLynx User Manual After clicking the Next button a progress meter will appear indicating install progress ENT setup status Please wait Datal yns installation is in progress IF you want to interrupt installation process press the Cancel button But in this case correct working of the program is not guaranteed Copying C Program Files Dataline DatalunxS erver exe All files Cancel The installation can always be sto
34. uplicate Select the modem to delete and click the Delete button 29 DataLynx User Manual 5 2 4 Duplicating 30 A modem listing may be created and duplicated This duplicating option is a great time saving feature for those with many modems with similar configurations e duplicate a modem DataLynx Monitor TRIAL VERSION isting go To menu File Tools Options Help Options gt Configure Server Server Addr Stop Polling Shut Down Server A list of modems if any configured for the Server will appear fe Server Configuration server Configuration Modemfsi COM Pat Alias COMI My Modem Maodify iew Delete gt Duplicate Click the Duplicate button and a window will appear asking for COM Port Alias Baud Rate Parity and 4 Retries Enter the necessary information and click OK to save changes otherwise click Cancel to discard changes lt Duplicate Modem COM Port Baud Rate 9600 y Parity None X Petries lo OK Cancel DataLynx User Manual 5 2 5 Connecting Connecting to a Datalynx Server is important because it allows the user to configure the DataLynx Server and retrieve its data files In the main screen portion labeled Server Address enter the Address Server Address localhost Then press the Connect button If the connection has been made the Connect button text will become
35. ut The user may change the polling state from the Monitor as well as from the Server program Changing the polling state can be useful when in the process of installing new PLCs or changing the PLC configuration to prevent the Server from receiving irrelevant data Click on the Start Polling button If the button states Stop Polling that means the Server is already listening Not Polling Modems Start Polling If successful the status should now read Polling Modems Polling Modems Stop Polling To Make the Server Stop Polling click on the Stop Polling button Polling Modems Stop Polling If successful the status should now read Not Polling Modems Not Polling Modems Start Poling DataLynx User Manual 5 2 9 Locking Unlocking Locking Unlocking is a useful feature for preventing unwanted modem configurations and Server polling state changes Steps to lock unlock are below Click the Lock tatus button Unlocked Lock A screen will appear EEEE ER x asking for the lock Please enterthe password to lockthe server code Passworal Enter the lock code and Click OK If successful the status section should now display a locked status Status Locked Warning If you forget lose the lock code you will NOT be able to unlock the Server Conversely to unlock the Server click the Unlock button enter the code and Click OK 35 DataLynx User Manual 5 2 10 Report
36. utes les sections applicables du Code national de pr vention des incendies du Code national de l lectricit et des codes de la National Electrical Manufacturer s Association NEMA Des organismes de r glementation ou des services gouvernementaux locaux peuvent galement vous aider d terminer les codes ainsi que les normes respecter pour assurer une installation et un fonctionnement s rs L omission de respecter la totalit des codes et des normes applicables peut entra ner des dommages l quipement ou causer de graves blessures au personnel Nous ne garantissons pas que les produits d crits dans cette publication conviennent votre application particuli re et nous n assumons aucune responsabilit l gard de la conception de l installation ou du fonctionnement de votre produit Nos produits ne sont pas insensibles aux d faillances et ne sont ni con us ni fabriqu s pour l utilisation ou la revente en tant qu quipement de commande en ligne dans des environnements dangereux n cessitant une s curit absolue par exemple l exploitation d installations nucl aires les syst mes de navigation a rienne ou de communication le contr le de la circulation a rienne les quipements de survie ou les syst mes d armes pour lesquels la d faillance du produit peut provoquer la mort des blessures corporelles ou de graves dommages mat riels ou environnementaux activit s risque lev La soci t Automationdirect co
37. ware is the property of AutomationDirect com or its suppliers and is protected by United States and International Copyright laws and International treaty provisions No ownership rights are granted by this Agreement or possession of the Software Therefore you must treat the Licensed Software like any other copyrighted material e g a book or musical recording except that you may make a single copy for backup or archival purposes Your rights and obligations in its use are described as follows 1 You may use and display this software on a single computer 2 You may make one copy of the software for archival purposes or you may copy the software onto your hard disk and hold the original for archival purposes 3 You may not modify or attempt to reverse engineer the software or make any attempt to change or even examine the source code of the software 4 You may transfer the software to another computer using the utilities provided However the software must be used on only a single computer at one time 5 You may not give or distribute copies of the software or written materials associated with the software to others 6 You may not sub license sell or lease the software to any person or business Return Policy The original licensee of the software can return it within thirty 30 days of purchase Please call us for a Return Material Authorization Number Limited Warranty AutomationDirect com does not warrant t

Download Pdf Manuals

image

Related Search

DataLynx User Manual

Related Contents

2S Trimmer User Manual  Normalizing speech transcriptions for Natural Language  SCADAPack E ISaGRAF 3 User Manual  Perfekthion - nova comercial  Bosch FLEXIDOME AN  NEC LT245 User's Manual  clicca quì per la guida pratica fai da te  HP E317 Quick Start Manual  GBC IB583032 laminator pouch  LCD n° 2, CNIAE, février 2008  