Contents

1. 11 Configuring internal Registers void SetADCConfig void weccceececeececseeeceeeeteeees 11 Reading back internal registers void GetADCConfig void ecceecceecseeeseeeeeeeees 12 Temperature Updates void UpDateTemp void iini 12 Serial Numbers Read Back void ReadSN void cecccsecccsececseeeeseeeeseeeeaeeeeseeeenees 12 Capturing data unsigned int DoCapture unsigned int SDB16BIT 12 Wieliele lg 6 0 ete e gi eamenenenten A ed ed ame cree ant re ae 12 Version 1 2 Page 4 of 12 SMT8090 User Manual Contacting Sundance You can contact Sundance for additional information by sending email to support sundance com Notes SHB stands for Sundance High speed Bus CommPort denotes an 8 bit communication port following the TI C4x standards Precautions In order to guarantee that Sundance s boards function correctly and to protect the module from damage the following precautions should be taken They are static sensitive products and should be handled accordingly Always place the modules in a static protective bag during storage and transition When operating make sure that the heat generated by the system is extracted e g a fan extracting heat or air blower It is vital for the SMT390 daughter module Version 1 2 Page 5 of 12 SMT8090 User Manual Outline description The SMT8090 365 is a single C6416 based module SMT365 combined with a dual high speed A
2. Configuring FPGA ___ Full configuration _ Loading keys and bitstream This command loads the bitstream contained in the directory where the application is running from as well as the Start and End Configuring FPGA __ FPGA Already configured Loading END key only In the case where the FPGA has already been configured by simply sending an End Key the FPGA retrieves it configuration It saves time Pulse on Config Line for FRGA reconfiguring void CPLDReset void By toggling the Config line it is possible to reload the FPGA with a different bitstream Configuring internal Registers void SetADCConfig void sets up the internal registers with values defined at the beginning of the application Version 1 2 Page 12 of 12 SMT8090 User Manual Reading back internal registers void GetaDCConfig void Reads back all the registers Clock selection frequency sample format scale etc that can be read back Temperature Updates void UpDateTemp void Once internal registers are configured it is possible to read temperatures on the 338 VP and 390 Serial Numbers Read Back void ReadSN void The serial number read back is not available anymore on systems shipped after 25 03 2005 The feature is removed due to recoding of the microcontroller A serial number is still present on a sticker on the modules This function still works but the serial number values read then back have no m
3. and J6 via MMCX BNC cables Make sure that the external signal meet the input characteristics of the SMT390 VP described in the SMT390 VP User Manual 7 Place the carrier board in the host system The following picture shows how connections are made at the top of the system rey ie wre oe i i TEEPE ERE EHE EEE ETES TRES La E ES a at a en merh ear La The following picture shows the CommPort connection at the back of the SMT310Q Note that the FMS are twisted i e one end should be blue and the other should show silver pins FMS Cable Version 1 2 Page 11 of 12 SMT8090 User Manual Software applications 3L application In a sub folder labelled 3L directory SMT6600 Systems SMT8090 365 you will find a C Test365 c a configuration Test365 cfg and a make makefile files Make sure the SMT365 has been configured with the 32 bit version of the firmware In a DOS prompt window simply type nmake to generate the 3L application file which can be loaded into the SMT365 by using the 3L Server 3L Diamond needs to be installed first This application executes the following steps e Configure FPGA e Configure Internal registers e Read back ADC registers e Set clock frequency e Updates temperature e Capture data Description of the functions in the test software Run8090 c The Run8090 c file provides functions to interact with the SMT390VP Those functions can be reused in other software
4. DC module SMT390 VP composed of SMT338 VP and SMT390 SMT365 characteristics single TMS320C6416 processor running at 600MHZ 64 bits gt Six 20MB s communication ports comm ports gt up to 16MBytes of ZBTRAM 133MHz gt 8MByte Flash ROM for boot code and FPGA programming Global expansion connector gt General purpose O connector High bandwidth data I O via 2 Sundance High speed Buses SHB SMT390 VP characteristics Two 12 bit ADCs AD9430 210 sampling at up to 210MHz via LVDS bus SLB Two Sundance High speed Bus SHB connectors Two 4 channel Rocket Serial Link RSL connector 2 5Gbits second each Two 20 MegaByte s communication ports Low jitter on board system clock Xilinx Virtex Il Pro FPGA VP30 6 50 Ohm terminated analogue inputs and outputs external triggers and clocks via MMCX or MMBX Huber and Suhner connectors User defined pins for external connections Compatible with a wide range of Sundance SHB modules gt TIM standard compatible The SMT8090 365 is a demonstration software for the evaluation of the SMT365 and SMT390 VP modules It can be used for prototyping 3G 3 generation systems and high speed data acquisition system with or without digital processor This document is an installation guide for the SW7T8090_365 demonstration system The SMT8090_365 application gets the DSP on the SMT365 to configure the SMT390_VP FPGA and control clock
5. SUNDANCE amp SMTS090_365 User Manual Certificate Number FM 55022 User Manual QCF42 Version 3 0 8 11 00 Sundance Multiprocessor Technology Ltd 1999 Version 1 2 Page 2 of 12 SMT8090 User Manual Revision History Date Comments Engineer Version 20 08 04 Corrections added to Hardware Installation 24 08 05 Updated section about serial number P 1 2 Microcontroller des not read a serial number anymore OT D nn Version 1 2 Page 3 of 12 SMT8090 User Manual Table of Contents REVISION AIS LION assainissement tiennent ne nette crane 2 Walle Of COM MSS Sn de transe dent dr etant 3 Bro ace ell gle SIA 1I e E PEE E E E T EE ie eet Mee Mr ee ee ea ee ee 4 INGOTS Sis sce 208 ter E ees EAEE TO ete a 4 Tf 21 6 2 10 10 9 eee nN eet en see eee cee eee nTar ear Ger nee Oe eee Rene enc et eee teem eee 4 OUUIAC desci UOM sa admis de a de ea ao nee in 5 ACROSS a be D a EP 6 HAN ATC INVOIM QES ES RES d ere 7 HAlAWAT ANS A lATIONL sn nd donner epoco tone ras u ste not es ddasoniedesbetanceapetiaduapennniwentes 8 DOMWAlrE APDIIGANON Sx ER elle E ARER 11 SUA ONC UNO D aah Gut Get ER 11 Description of the functions in the test software Run8090 c 11 Configuring FPGA Full configuration Loading keys and bitstream 11 Configuring FPGA FPGA Already configured Loading END key only 11 Pulse on Config Line for FPGA reconfiguring void CPLDReset void
6. eaning Capturing data unsigned int DoCapture unsigned int SDB16BIT This function captures data from both channels one after the other not simultaneously Data are then stored into two separate files into the directory where the application has been started Files are called ChannelA txt and ChannelB txt Note that without configuring the FPGA followed by its internal registers none of the other options will work Matlab application The SMT8090_365 is also provided with a matlab application SL folder test m which displays raw data captured with 3L application as well as the FFT
7. frequencies clock routings data format and data capture The DSP grabs data from both channels and stores them into a file for further processing like display and FFT Version 1 2 Page 6 of 12 SMT8090 User Manual Architecture The following diagram shows the architecture of the SW7T8090 system q gt gt ay qua Analogue Data Data Control Data Processing Connection Global Bus SHB Comm SDB Connection Connection Port Connection SMT365 DSP Module 1 TIM site 1 k PC Host SMT390 DAQ Module 2 SMT310Q TIM site 2 TIM site 3 TIM site 4 Version 1 2 Page 7 of 12 SMT8090 User Manual Hardware involved The SMT8090 365 is built around two main modules but also involves a carrier board and some cables to interconnect them and allow them to communicate with each other and to access the PC gt 1x SMT310Q PCI carrier 1x SMT365 Single C6416 based module to be plugged on site 1 of SMT310Q gt 1x SMT390 VP Dual ADC module to be plugged on site 2 of SMT310Q gt 1x FMS cable 20cm to connect T1C0 to T2C3 at the back of the SMT310Q 1x SMT516 SHB to SHB PCB to connect SHBA SMT365 to SHBA SMT390 gt 1x SMT511 SHB to SHB cable to connect SHBB SM7T365 to SHBB SMT390 4x MMCX to BNC cables to connect an external analogue signal source to Ji to J4 and an ex
8. ternal clock source when using external sampling clock to J5 and J6 Version 1 2 Page 8 of 12 SMT8090 User Manual Hardware installation Here are the steps to follow to install the SMT8090 365 system 1 Place the SM1365 on TIM site 1 of the carrier board SMT3100 2 The following are then required to mount SMT338 VP 390 on the SMT310Q Holes mounted with Nylon screw M2x10 and 4 Nylon nuts M2 SMT338 VP SMT390 Holes mounted with Nylon screw M2x10 and 4 Nylon nuts M2 TIM 3 3V a First fit two Nylon screws M2x10 pointing out the head of the screws on bottom side Version 1 2 Page 9 of 12 SMT8090 User Manual b Then fit four M2 nuts on each screw c Place the SMT338 on the second site SMT365 already on first site on the SMT310Q and fit two metal pillars 3 3 Volts apenas ns d Place the SMT390 on top of the SMT338 VP Make sure that both modules fit firmly e Fit two M2 nuts on the Nylon screws and two M3x4 screws in the 3 3V pillars 3 Connect CommPort 0 of the SMT365 to CommPort 3 of the SMT390 T1C0 to T2C3 via an FMS cable at the back of the SMT310Q 4 Connect SHBA on the SMT365 to SHBA on the SM 1390 VP via the SMT516 SHB to SHB PCB Version 1 2 Page 10 of 12 SMT8090 User Manual 5 Connect SHBB on the SMT365 to SHBB on the SMT390 VP via the SMT511 SHB to SHB cable 6 Connect external sources to J1 J4 J5

Download Pdf Manuals

image

Related Search

SMT8090_365 Sundance Multiprocessor Technology Ltd.

Related Contents

DAP  Instruções de montagem e de operação  Hannspree MAC-001029 ST48-12A1 User's Manual  Jenn-Air Range SCE4340 User's Manual  GRANPOWER5000 ES200 取扱説明書への追記  TR-202 - Sitron  www.gocamera.it  TC-3400 Manual - ThermoElectric Cooling America  Sistema Residencial EPIQ Energy Manager (EEM)  StarTech.com 4 User 16 Port Cat5 Matrix IP KVM Switch  