1. AUXILAB S L Material de laboratorio Laboratory supplies Manual de instrucciones Operating instructions Refractom tros 01 Descripci n Description 1 Entrada luz 2 Selector escala 3 Anillo polarizador 4 Cubre prisma 5 Anillo de ajuste di ptrico Ocular de mano universales Universal hand refractometers 1 Entrance light prism 2 Scale selector 3 Polarizer ring 4 Cover plate 5 Diopter adjustment ring Eyepiece 02 Especificaciones t cnicas Technical specifications Referencia Code 50308090 50301090 Rango Range 1 333 1 515 nD 0 90 Brix Precisi n Precision 0 0005 nD 0 2 Escalas Scales 1 333 1400 nD 0 42 1400 1470 nD 42 71 1470 1520 nD 71 90 Dimensiones Dimensions 37x34x200 mm 37x34x200 mm Pesos Weight 600 g 600 g Pol Morea Norte Calle D N 6 31191 Beriain Navarra ESPA A Tel fono 34 948 310 513 Fax 34 948 312 071 948 310 500 correo Wauxilab es www auxilab com CIF B31072218 AUXILAB S L A Material de laboratorio Laboratory supplies 03 Procedimiento Use process 1 Dirija la parte frontal del refract metro hacia la luz y observando a trav s del ocular gire el anillo de ajuste di ptrico 5 hasta ver con total nitidez la ret cula de la escala 2 Mediante el anillo polarizador 3 elimine el cromatismo de la luz hasta obtener una l nea n tida de separaci n entre la zona clara y oscura en la escala 3 Regule l
2. a entrada de luz al prisma 1 4 Ajuste a cero No es necesario puesto que el equipo ya viene ajustado de origen 5 Abra el cubre prisma 4 limpie la superficie con un pa o suave de algod n coloque 1 2 gotas de la soluci n problema Cierre nuevamente el cubre prisma presione ligeramente y observando la l nea l mite en la escala correspondiente obtendr la lectura del ndice de refracci n nD o grado brix de la soluci n problema 6 Realice la selecci n de la escala adecuada mediante el selector de escala 2 7 Finalizada la medici n retire la muestra con un pa o humedecido y finalmente limpie el prisma y el cubre prisma con un pa o suave y seco 04 Mantenimiento Attentions and maintence 1 Despu s de su uso no derrame agua u otro l quido sobre el prisma para limpiarlo af n de evitar que entre al interior y deteriore el refract metro 2 Dado que se trata de un instrumento de precisi n selo cuidadosamente evitando cualquier golpe as como el contacto con las partes pticas As mismo el ambiente de trabajo debe mantenerse seco y libre de agentes corrosivos con el fin de evitar formaci n de humedades y deterioro prematuro del instrumento 3 La temperatura de referencia es de 20 C Efect e la compensaci n de temperatura de trabajo diferente mediante la tabla proporcionada 05 Accesorios Accessories Pipeta Suction tube Destornillador Screw driver Pa o de algod n Soft cotton clot
3. e Pol Morea Norte Calle D N 6 31191 Beriain Navarra ESPA A Tel fono 34 948 310 513 Fax 34 948 312 071 948 310 500 correo Wauxilab es www auxilab com CIF B31072218 AUXILAB S L Material de laboratorio Laboratory supplies TABLA 1 Tabla de correcci n grados Brix temperatura TABLE 1 Correction chart Brix grades temperature Temp Porcentaje de la soluci n Solution percentage Temp 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Sustraer al valor de la medida Substract from the measured value 10 0 52 0 58 0 59 0 81 0 84 0 87 0 89 0 71 0 72 0 74 0 74 0 74 0 75 0 76 0 77 11 0 48 0 51 0 54 0 55 0 58 0 61 0 63 0 65 0 65 0 67 0 67 0 67 0 68 0 68 0 69 12 0 44 0 47 0 49 0 50 0 52 0 55 0 57 0 58 0 58 0 60 0 60 0 60 0 60 0 61 0 61 gt a 13 0 39 0 42 043 044 045 049 0 50 0 51 0 51 0 53 0 53 0 53 0 53 0 53 0 53 z z 14 0 35 0 37 0 38 0 39 0 40 0 42 0 43 0 44 0 44 0 45 0 45 0 45 0 45 0 45 0 46 E z 15 0 29 0 31 0 32 0 33 0 34 0 35 0 36 0 37 0 37 0 38 0 38 0 38 0 38 0 38 0 38 0 38 0 37 0 37 16 0 24 0 25 0 26 0 27 0 28 0 28 0 29 0 30 0 30 0 30 0 31 0 31 0 31 0 31 0 31 0 30 0 30 0 30 17 0 18 0 19 0 20 0 20 0 21 0 21 0 22 022 023 023 0 23 0 23 0 23 0 23 0 23 023 0 23 0 22 18 0 12 0 13 0 13 0 14 0 14 0 14 0 15 0 15 0 15 0 15 0 15 0 15 0 15 0 15 0 15 0 15 0 15 0 15 19 0 06 0 06 0 07 0 07 0 07 0 07 0 07 0 08 0 08 0 08 0 08 0 08 0 08 0 08 0 08 0 08 0 08 0 07 A adir al valor de la medida Add to
4. h 1 Aim the front end of the refractometer to the direction of bright light and adjust the diopter adjustment ring 5 until the reticle can be seen clearly 2 Polarizer ring While measuring a light concentration solution you will find chromatism in view you could reduce it by rotating 3 3 Light Prism If the light is not enough you could rotate and adjust D 4 Adjust to zero Itis not necessary this instrument has been adjusted before in factory 5 Measurement Open the cover plate 4 clean the surface of prism by soft cotton cloth and drop 1 2 drops of solution to be measured Close the cover plate press it lightly the read the corresponding scale of light blue boundary the reading is refractive index of measured solution 6 Rotate There are three scales in the instrument you could get them by rotating 2 7 Store After measurement clean away the adhered on the surface of prism and cover plate by moist gauze 1 After usage don t use water to wash the instrument to avoid damages in the instrument 2 Asit a precision optical instrument you should hand it gently and take good care of it Don t touch and scratch the optical surfaces It should be kept in a dry clean and non corrosiveness environment to prevent the surface of the humidity Please avoid strong shock during transportation 3 The reference of temperature in 20 C In operation the temperature compensation should be made according to the tabl
5. the measured value 21 0 06 0 07 0 07 0 07 0 07 0 07 0 08 0 08 0 08 0 08 0 08 0 08 0 08 0 08 0 08 0 08 0 08 0 07 22 0 13 0 14 0 14 014 014 015 0 15 0 16 0 16 0 16 0 16 0 16 0 16 0 16 0 15 0 15 0 15 0 15 23 0 20 021 0 21 022 0 22 0 23 0 23 0 23 0 23 0 24 0 24 0 24 0 24 0 23 0 23 0 23 0 23 0 22 24 0 27 0 28 0 29 029 0 30 0 30 0 31 0 31 0 31 0 32 0 32 0 32 0 32 0 31 0 31 0 31 0 30 0 30 25 0 34 0 35 0 36 0 37 0 38 0 38 0 39 0 39 0 40 0 40 0 40 0 40 0 40 0 39 0 39 0 39 0 38 0 37 28 0 42 0 43 0 44 0 45 0 46 0 46 0 47 0 47 0 48 0 48 0 48 0 48 0 48 0 47 0 47 0 46 0 46 0 45 27 0 50 0 51 0 52 053 054 0 55 0 55 0 56 0 56 0 56 0 56 0 56 0 56 0 55 0 55 0 54 0 53 0 52 28 0 58 0 59 0 60 0 61 0 62 0 63 0 64 064 0 64 0 65 0 65 0 64 0 64 0 64 0 63 0 62 0 61 0 60 29 0 66 0 67 0 68 0 69 0 70 0 71 0 72 0 73 0 73 0 73 0 73 0 73 0 72 0 72 0 71 0 70 0 69 0 68 30 0 74 0 75 0 77 0 78 0 79 0 80 0 81 0 81 0 81 0 82 0 81 0 81 0 81 0 80 0 79 0 78 0 77 0 75 Pol Morea Norte Calle D N 6 31191 Beriain Navarra ESPA A Tel fono 34 948 310 513 Fax 34 948 312 071 948 310 500 correo auxilab es www auxilab com CIF B31072218

Download Pdf Manuals

image

Related Search

AUXILAB S.L. auxilab sl

Related Contents

die Bedienungsanleitung des Mares Puck…  899 取扱説明書ダウンロード(1.17MB  Page 1 Page 2 Page 3 ひびわれに沿ってコンクリート深部にまで 注入剤  View/Open - Calhoun: The NPS  Samsung SWR1251BK User Manual  TECHNICAL SERVICE MANUAL  Colleague 2210 Manual  ポリコンFRP管 強化プラスチック複合管 施工について (PDF:13.3MB)  Manual Usuario Aspects LW211  Chamberlain 942FP User's Manual  