2. USER MANUAL Line Interactive UPS Uninterruptible Power System IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models Line Interactive 400 600 and 800 that should be followed during installation and maintenance of the UPS and batteries Safety CAUTION This UPS utilizes voltages that may be hazardous Do not attempt to disassemble the unit The unit contains no user serviceable parts Only factory service personnel may perform repairs Internal battery voltage is 12Vdc Sealed lead acid 6 cells battery Connection to any other type of receptacle other than a two pole three wire grounding receptacle may result in s shock hazard as well as violate local electrical codes In the event of an emergency turn the power switch to the off position and disconnect the power cord form the AC power supply to properly disable the UPS Do not allow any liquids or any foreign object to enter the UPS Do not place beverages or any other liguid containing vessels on or near the unit This unit intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in locations where there is standing or running water or excessive humidity Do not plug the UPS input into its own output Do not attach a power strip or surge suppressor to the UPS Do not attach non computer rel
3. ated items such as medical equipment life support equipment microwave ovens or vacuum cleaners to UPS To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces Unplug the UPS prior to cleaning and do not use liquid or spray detergent Do not dispose of battery or batteries in a fire The battery may explode Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries 1 Remove watches rings or other metal objects from the hand 2 Use tools with insulated handles 3 Wear rubber gloves and boots 4 Do not lay tools or metal parts on the top of batteries 5 Disconnect charging source prior to connecting or disconnecting batteries terminal e Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing batteries replace with the same type and number of the sealed lead acid batteries The maximum ambient temperature rating is 40 C e This pluggable type A equipment with battery already installed by the supplier is operato
4. ben des Herstellers 1 Introduction This UPS is specially designed for Personal Computer with multi functions Its light weight compact design perfect fits to the limited working environment The line of UPS is equipped with boost and buck AVR to stabilize input voltage range It is also built in with DC start function This function enables the UPS to be started up without AC power supplied Although its a small UPS its equipped with Smart RS 232 Communication Port to offer users more benefits The download software helps users monitor UPS inside status The main features of the UPS are listed below Microprocessor control guarantees high reliability Equipped with Boost and Buck AVR Built in RS 232 Communication Port Free Software Download from the Internet Please check Free Software Download in Installation amp Operation for detail information Green Power Function for energy saving DC Start Function Auto restart while AC recovery Compact size Light Weight Provides Modem Phoneline surge protection USB Option 2 Installation and operation 1 Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping If any damage is discovered repack the unit and return it to the place of purchase 2 Charging This unit is shipped from the factory with its internal battery fully charged however some charge may be lost during shipping and the battery should be recharge
5. d prior to use Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours with no load no electrical devices such as computers monitors etc connected 8 hours 3 Placement Install the UPS unit in any protected environment that provides adeguate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an environment where the ambient temperature or humidity is high RQR OR a GA On the other hand place the UPS away from the monitor at least 20cm to avoid interference K 4 Connection Plug the UPS into a 2 pole 3 wire grounded receptacle Then connect one computer related device into each of the power receptacles supplied on the back of the UPS 5 Turn On Off To turn on the UPS unit press the power switch lightly To turn off the UPS unit press the power switch again 6 DC Start All this Series are equipped with DC Start To start the UPS when AC utility power is not available simply press the power switch 7 Green Power Function This UPS is equipped with Green Power Function For saving power and protecting battery the method of deep discharging protection is adopted on inverter mode 8 Free Download Software WinPower H Go to the website http www ups software download com winpower htm mw Choose the operation system you need and f
6. ollow the instruction described on the website to download the software m When downloading all required files from the internet enter the serial No 511C1 01220 0100 478DF2A to install the software Note The Power Switch must be kept in the ON position otherwise the UPS will be disabled and your equipment will not be protected during a power failure 3 System Description Front panel 1 Power Switch 2 LED Indicators AC Mode Green lighting Battery Mode Green flashing Back Panel 1 Output receptacles 4 USB Communication Port 2 AC input with AC fuse 3 Modem Phoneline Surge Protection 4 Trouble Shooting Symptom Possible Cause Remedy No LED display on the front panel 1 Missing battery 1 Charge battery up to 8 hours 2 Battery defect 2 Replace with the same type of battery 3 Power switch is not pressed 3 Press a power switch again Alarm buzzer Overload of the UPS Verify that the load matches failure back up time is shorten beeps the UPS capability specified in continuously the specs when AC Supply is normal When power 1 Overload of the UPS 1 Remove some noncritical load 2 Battery voltage is too low 2 Charge battery 8 hours or more 3 Battery defect due to high temperature operation environment or improper operation to battery 3 Replace with the same type of battery Mains normal bu
7. r installable and may be operated by laymen During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA e Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible Wichtige Sicherheitshinweise Bitte lesen Sie diese Hinweis sorgfaltig durch E Vor jedem rcinigen ist das Ger t vom Stromnetz zu trennen Verwenden Sie Keine Fl ssig oder Aerosolreiniger Am besten eignet sich ein angefeuchtetes Tuch zur Reinigung m Das Ger t ist vor Feuchtigkeit zu sch tzen m Offncn Sie niemals das Ger t Das Ger t darf aus Gr nden der elektrischen Sicherheit nur von authorisicrtem Servicepersonal ge ffnct Werdcn H Bei der Installation is darauf zu achten das der Gesamtableitstrom der USV und der and der USV angeschlossenen Verbraucher den Maximalwert von 3 5mA nicht berschreiten M VORSICHT Explosionsgetahr bei unsachgem Ben Austausch der Batterie Ersatz nur durch denselben order einem vom Hersteller empfoblenem hnlichen Typ Entsorgung gebrauchter Batterien nach Anga
8. t LED is flashing 1 Fuse is blown 1 Replace the same type of fuse 2 Power cord is loose 2 Reconnect the power cord properly If any abnormal situations occur that are not listed above please call service people immediately 5 Specification 6 MODEL 400 600 800 CAPACITY 400VA 240W 600VA 360W 800VA 480W INPUT 110 120VAC or 220 230 240VAC 81 140VAC or 162 290VAC 45 65 Hz Auto Sensing 110 120 220 230 240VAC Regulation Batt Mode 10 Frequency 50Hz or 60Hz Frequency Regulation Batt Mode 1 Hz utput Waveform Modified Sinewave Battery Type 6V4Ah x 2 or 12V7Ah x 1 12V4 5Ah x 1 JE Backup Time at a PC oad with 15 monitor 12 minutes 23 minutes 34 minutes 8 hours to 90 after complete discharge TRANSFER TIME 2 6 ms INDICATOR Green lighting Green flashing Sounding every 10 seconds Sounding every second Sounding every 0 5 second Battery Replacement Sounding every 2 seconds Fault Continuously sounding PROTECTION Full Protection Discharge overcharge and overload protection PHYSICAL Dimension DXWXH mm 330X100X140 WEIGHT Net Weight 5kgs 6kgs 6 5kgs ENVIRONMENT perating Environment 0 40 C 0 90 relative humidity non condensing Noise Level Less than 40dB INTERFACE USB

Download Pdf Manuals

image

Related Search

Blazer User Manual 2024 chevy blazer user manual 2020 chevy blazer user manual blazer led speaker user manual 2023 chevy blazer user manual

Related Contents

Samsung P2050N User Manual  製品マニュアル - プリンストンテクノロジー  EzBlock 取扱説明書  Lenovo ThinkServer TS130  Guide de démarrage rapide du DVR HREP2  EN Pizzarette / DE Pizzarette / FR Pizzarette SE  Tyco LPE-200 User's Manual  アルミスイングアーム(4cmロングタイプ)取扱説明書  caracteristicas_MPC6006  Samsung Galaxy Tab 2 10.1 User Manual  