Home

ReliOn Model H-0565-0 User's Manual

image

Contents

1. wiping base and transducer being very carefully not to damage any components Set aside to dry clean tank Mix two tablespoons of bleach to 1 gallon of water The tank is a two gallon tank so fill the tank half way then add the bleach Put approximately 2 cups of the solution in the tank Shake the tank Dump out solution Put approximately 2 cups of plain water in tank Shake the tank Dump out water Take soft dry cloth you can actually reach up into tank and dry entire tank Do this once a week For best results replace the filter every 45 uses or 240 hours The Kaz Demineralization Cartridge Model DC 51 can be purchased at Wal Mart If you have trouble removing the tank cap try adding liquid soap around the cap in order to loosen it Read and save these instructions for best results MODEL H 0565 0 ReliOn Owner s Manual ULTRASONIC HUMIDIFIER Model H 0565 0 Series For product service call our toll free costumer service line at 1 866 872 7442
2. RELI ON ULTRASONIC HUMIDIFIER Operation Instructions 1 Make sure there is water in the water tank 2 Water level must be adequate in the base in order for the unit to produce mist This unit does not have an automatic shut off 3 Switch is in the OFF position plug cord into a 120 volt AC wall outlet gt Slide to ON position Indicator will illuminate when power is on 5 Set mist intensity control Slide control to the right to increase mist output slide to the left to decrease mist output 6 Allow a few minutes for water to fill the reservoir to produce mist It may take up to thirty minutes to saturate if you are using a new demineralization cartridge for mist to appear 7 Turn off reduce mist intensity or open door to room if indoor relative humidity is above 50 or condensation forms on the wall or windows 8 Make sure the power is off when moving the unit or refilling the water tank The fan will continue to operate even if the water tank is empty 9 In case of high temperature or filtration malfunction this product may produce a sour or amino acid smell If this occurs please rinse the filter with distilled water or replace the filter 10 If you have any questions or comments call toll free 1 866 872 7442 Always unplug the humidifier before filling CARRYING HANDLE DIRECTIONAL MIST NOZZLE WATER TANK WATER VALVE RESERVOIR DEMINERALIZATION AIR OUTLET CARTRIDGE inclu
3. ded in certain models WATER SENSOR ULTRASONIC NEBULIZER BASE POWER INDICATOR MIST INTENSITY CONTROL POWER SWITCH Model H 0565 0 Filling the Water Tank Remove mist nozzle from the water tank Turn tank upside down after removing it from the base Open tank by turning cap counterclockwise Rinse and wipe clean Fill the water tank with cool tap water and replace the cap Turn upside down to check for leaks If leaks appear remove cap and re tighten Be sure the rubber tank ring is properly placed to minimize leaks Use of very cold water may temporarily hinder mist output Filling humidifier with hot or warm water could cause damage to the unit To reduce lime or calcium deposit in your unit it is recommended to use the Kaz Demineralization Cartridge Model DC 51 Distilled water may be used to reduce mineral deposits Keep base and nebulizer clean for more effective mist output Replace water tank on the base and reposition the mist nozzle on the tank If white dust occurs due to hard soft water please change to distilled water WARNING Cord should be placed out of foot traffic and away from heated surfaces Check cord before every use DO NOT use unit if cord is damaged To prevent fire shock or personal injury DO NOT use an extension cord Medication and water treatments should not be added to water or ANY part of humidifier Mist nozzle should not be covered Placing unit in direct sunlight or high temperature area
4. is not recommended DO NOT overfill water tank or immerse the unit into water Condensation on walls floor and furniture might occur if unit is left unattended in a closed room DO NOT direct mist nozzle towards walls furniture or children Place unit on non metallic waterproof surfaces and away from water sensitive furniture Touching the ultrasonic nebulizer while plugged in could result in burns For product service call toll free 1 866 872 7442 DANGER If operated without water in water tank it will cause damage to machine Unit is made for indoor use only Humidifier should be unplugged if being cleaned or not in use DO NOT tilt or move humidifier while in use DO NOT use near water Wrapping the cord around the unit for storage is not recommended RELI ON ULTRASONIC HUMIDIFIER Cleaning Instructions For best results clean your humidifier at least once a week To begin To Turn off and unplug humidifier Empty water in tank and base of humidifier Remove filter cartridge clean base Mix two tablespoons white vinegar to two cups of water With a soft cloth and or a cotton ball dip into the solution wiping the entire base area being very careful not to damage any components Be sure to clean the transducer located at the bottom of the base it is a little round silver disk Be very careful not to damage transducer Next with a soft cloth or a cotton ball dip into plain water you are basically rinsing

Download Pdf Manuals

image

Related Search

Related Contents

Milwaukee 9050 User's Manual  Mode d`emploi Autre Dentacontrol  GE Profile J2B918CEK / J2B918WEK / J2B918BEK Dual Fuel (Electric and Gas) Kitchen Range  4.9 Laserresonator  PLASMA TV MANUAL DE SERVICIO  DDX672BH DDX492 DDX415BT DDX392 DDX372BT  Cosmorex SE Owner's Manual  BC 4535 II - AL-KO  Drahtlose Wegfahrsperre  Samsung RF67VBPN side-by-side refrigerator  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.