1. O O O O O Document Number Prec en User cursor is on it changing to off if the cursor is moved on The general Disablement LED will be cleared if no other disablements are present To quit the disable enable mode To exit the Select Mode press the Select On Off button The Select On LED will clear The cursor indication will clear Set the Access Controls Keyswitch back to position 0 to lock the controls To Disable Enable the Fault Routing Output To Access disable enable mode Turn the Access Controls Keyswitch on the panel door to position 1 Press the Select On Off button to enter the Select Mode The Select On LED will light The cursor indication will pulse the yellow Zone 1 fault disabled test LED To select the Fault Routing Output Use the Select f button to move the pulsed cursor indication up through the fault LEDs until it pulses the Fault Routing Fault Disabled LED The Select button moves the cursor down To disable the Fault Routing Output Press the Disable button to disable the Fault Routing Output The Fault Routing Fault Disabled LED will change to the On flash indication while the cursor is on it changing to steady if the cursor is moved The general Disablement LED will light To enable the Fault Routing Output Press the Enable button to enable the Fault Routing Output The Fault Routing Fault Disabled LED will change to the Off flash
2. CURSOR Sequence Zone 1 Fault LED Zone 2 Fault LED Zone n Fault LED n 2 4 8 16 32 depending on panel Sounder Fault Disabled amp Test LEDs Fire Protection Fault Disabled LED Fire Routing Fault Disabled LED Fault Routing Fault Disabled LED Precept Panel Controls not Enabled y Turn ACCESS CONTROLS keyswitch to 1 y Precept Panel Controls Enabled rc Turn ACCESS om CONTROLS lt ja keyswitch to 0 S y A Press SELECT ON OFF button vy Precept Panel SELECT mode Active SELECT ON OFF LED illuminated y Precept Panel zj SELECT cu A Zone 1 Fault LED rsor flashes a y y Y y Press SELECT v button Press SELECT button Press ENABLE button Press DISABLE button Press TEST button y Press SELECT ON OFF button Precept Panel SELECT cursor moves Precept Panel SELECT cursor moves Precept Panel Selected Circuit Precept Panel Selected Circuit Precept Panel Selected Circuit in Test mode Precept Panel SELECT mode inactive to next LED to previous LED returned to normal Disabled If Zone then Zone Fault LED SELECT cursor clears operation Circuit Fault LED pulses pulses ON flash SELECT LED clears LED pulses OFF flash ON flash Chan
3. button o The General Fire LED will flash o The sounders operate e Set the Access Controls Keyswitch back to position 0 to lock the controls 4 User Operating Instructions for Optional Clock Module Normal Time Display no LCD backlight HH MM SS HH MM SS D N ON D N OFF or 4 1 To Display Alarm Event Count To display current alarm count press the Test Display button Alarm count display ALARMS NNNN NNNN 0000 to 9999 The Test Display button does not need to be held pressed The Alarm Count will be displayed for 5 seconds and then the display will return to normal Note If the Alarm Counter feature is not enabled then the normal time will still be displayed and the LCD backlight will illuminate when Test Display is operated 4 2 To access the User Clock Module Edit Functions Select Access Control key switch to position 1 Press the SELECT ON OFF switch Document Number Prec en User Rev 2 Checked by AJC Use the Up down keys to scroll the cursor LED indication through the selectable options on the panel display LEDs until the LCD backlight illuminates Normal Time Display HH MM SS HH MM SS D N ON D N OFF or e To select Day Night Mode to On Off Press the SELECT ON OFF button to enter Day Night mode On Off Set Display D N ON D N OFF Change ot Change Pressing ENABLE or DISABLE toggles setting betw
4. indication while the cursor is on it changing to off if the cursor is moved on The general Disablement LED will be cleared if no other disablements are present To quit the disable enable mode To exit the Select Mode press the Select On Off button The Select On LED will clear The cursor indication will clear Set the Access Controls Keyswitch back to position 0 to lock the controls Rev 2 3 5 O O O O O O 3 6 e O O Page 7 of 13 To Disable Enable Fire Protection Outpui s To Access disable enable mode Turn the Access Controls Keyswitch on the panel door to position 1 Press the Select On Off button to enter the Select Mode The Select On LED will light The cursor indication will pulse the yellow Zone 1 fault disabled test LED To select the Fire Protection Output Use the Select t button to move the pulsed cursor indication up through the fault LEDs until it pulses the Fire Protection Fault Disabled LED The Select button moves the cursor down To disable the Fire Protection Output Press the Disable button to disable the Fire Protection Output The Fire Protection Fault Disabled LED will change to the On flash indication while the cursor is on it changing to steady if the cursor is moved The general Disablement LED will light To enable the Fire Protection Output Press the Enable button to enable the Fire Protection Output The Fire Protecti
5. switched off Document Number Prec en User Rev 2 e To terminate the sounder test o Press the Test button again or press the Enable button to clear the test condition enabling normal operation of sounders o The sounders will silence o The Sounder Test LED will change to the Off flash indication while the cursor is on it changing to off if the cursor is moved on o The general Test LED will be cleared if no other circuits are in the test condition e To quit test selection mode o To exit the Select Mode press the Select On Off button o The Select On LED will clear o The cursor indication will clear o Set the Access Controls Keyswitch back to position 0 to lock the controls 3 8 To Enable Disable Delay Mode e To access delay mode selection o Turn the Access Controls Keyswitch on the panel door to position 1 e To enable the delay o Press the Delay On Off Override button once to enable the Delay Mode o The Delay On Off LED will light e To display the outputs configured to be delayed o With the panel in the quiescent condition select the Access Controls Keyswitch to position 1 o Press and hold the Disablement button o The fault disabled LED on each output set to the delay mode will illuminate o The indications will clear when the Disablement button is released e To disable the delay o With the Delay On press the Delay On Off Override button once to disa
6. the panel display resets the zones outputs and and lif silence before Resets Reset configured alarms silence operates the reset relay switch has been operated Silence Buzzer 1 Press to stop the buzzer sounding in fire or fault conditions 2 In 2 Stage Delay Mode with stage 1 delay running press to start stage 2 delay otherwise all delayed outputs operate when Stage 1 timer times out When controls are locked or unlocked When the panel is in the fire condition and the delay is running Controls are locked or unlocked 1 Press once to Enable the delay mode lighting the adjacent delay on LED Press again to disable the delay mode and turn off the LED 1 When controls are unlocked and delay period is set to a value gt 0 Delay SMOOVE 2 Overrides the delay when delay is running All delayed 2 When the panel is in the outputs will operate immediately fire condition and the delay is running Press to illuminates all LEDs on the display and operate When controls are locked or Test Display the buzzer All indications remain active for approx 5 unlocked seconds after button release Document Number Prec en User Rev 2 Page 12 of 13 22 12 09 Written by RKP Checked by AJC 8 Routine Testing and maintenance See Precept Log Book for details 9 User responsibilities See Precept Log Book for details 10 Precept Isolate De isolate Test Mode Select Flowchart
7. AL FAULT POWER SUPPLY FAULT SYSTEM FAULT GENERAL TEST OD N OP ON a INT a GENERAL DISABLEMENT SILENCE BUZZER COMMUNICATION FAULT SOUNDER FAULT DISABLED DELAY ON OFF SOUNDER TEST OVERRIDE FIRE PROTECTION FAULT DISABLED FIRE ROUTING FAULT DISABLED TEST DISPLAY OQQOOQ 0000000000000000 FAULT ROUTING FAULT DISABLED O O O O O O O O O O O O O O 10000000000000000 LT 1 DETERMINE THE CAUSE OF THE FAULT 2 PRESS SILENCE BUZZER 1 THE RED ZONE INDICATOR WILL PULSE SHOWING THE LOCATION OF THE FIRE 2 CARRY OUT THE REQUIRED FIRE DRILL 3 TO SILENCE ALARMS PRESS SILENCE ALARMS 4 TO RESET FROM THE FIRE CONDITION PRESS RESET DETECTION MEASURES Access Controls Keyswitch 0 Controls Locked 1 Controls Unlocked User Instructions Zone Location Indications Indicator Description ania Operating Condition User Generated Zone Location Red Flashes when zone is in a fire condition turning to steady Text on operation of Silence Alarms User Generated Zone Location Yellow Flashes when zone is in a fault condition Illuminates Text steady when zone is disabled or in test Document Number Prec en User Rev 2 Page 11 of 13 22 12 09 Written by RKP Checked by AJC 7 Precept Repeater Panel User Controls 16 zone panel shown Pai A A POWER SUPPLY ON ZONE LOCATION FIRE
8. EVACUATE FIRE ROUTING ACTIVE SILENCE RESOUND ALARMS GENERAL FAULT POWER SUPPLY FAULT SYSTEM FAULT GENERAL TEST eo ON Pap OP GENERAL DISABLEMENT SILENCE BUZZER COMMUNICATION FAULT SOUNDER FAULT DISABLED DELAY ON OFF SOUNDER TEST OVERRIDE FIRE PROTECTION FAULT DISABLED FIRE ROUTING FAULT DISABLED TEST DISPLAY OQQG0 00 O O O O O O O O O O 0000000000000000 FAULT ROUTING FAULT DISABLED 10000000000000000 FIRE 1 THE RED ZONE INDICATOR 1 DETERMINE THE CAUSE WILL PULSE SHOWING THE LOCATION OF THE FIRE 2 CARRY OUT THE 3 CALL YOUR SERVICE REQUIRED FIRE DRILL ENGINEER 3 TO SILENCE ALARMS PRESS SILENCE ALARMS 4 TO RESET FROM THE FIRE CONDITION PRESS RESET ALTERNATIVE FIRE DETECTION MEASURES Access Controls Keyswitch 0 Controls Locked 1 Controls Inlocked Switch ae Description Functionality Button Availability Operates all sounders continuously and lights the When controls are unlocked Evacuate Evacuated LED adjacent the button until the silence button is operated Silence Resound Following a fire alarm condition 1st operation stops sounders The General Fire LED and the Zonal fire LED When controls are unlocked Alarms will change from flashing to steady 2nd operation restarts the previously silenced sounders When controls are unlocked Clears
9. Miscias actcluatchertnaetadel 4 5 2 TO SILENCE THE FIRE ALARM SOUNDERS 10 2 2 USER CONTROLS SHOWING OPTIONAL CLOCK 9 3 TO RESOUND THE FIRE ALARM SOUNDERS MODULE catbcicht nea abactttek tainese Aaucassa Beata 5 AFTER THEY HAVE BEEN SILENCED 10 BARGE RTE EER CONTROLS DIGABHENENEAND 5 4 TO RESET THE PANEL amp REPEATER S FROM A TEST CONDITIONS 0 cccccceeceeeeececeeeeseeaeeeeeeeees 6 E ao ALARN eosiad goat acetone Ae ae 10 i 5 TO OPERATE THE FIRE ALARM SOUNDERS IN 3 1 TO DISABLE ENABLE ANY ZONE OR ZONES 6 EVACUATE MODE aaisen 10 3 2 TO DISABLE ENABLE ALL SOUNDERS 6 5 6 IF A FAULT IS DETECTED sciscsdstecnsea cassie 10 3 3 a E THE FIRE ROUTING 7 5 7 TO SILENCE THE BUZZER ececeseccececececeeeeeee 10 3 4 To DISABLE ENABLE THE FAULT ROUTING 6 PRECEPT REPEATER PANEL OPERATION 16 SnO AAE ESE EOE 7 ZONE PANEL SHOWN scsssssssssesssetsenstenssnenees 11 3 5 To DISABLE ENABLE FIRE PROTECTION 7 PRECEPT REPEATER PANEL USER CONTROLS QUIPUT Scania eared A O ene 7 16 ZONE PANEL SHOWN scsesesesesseseseeeeeeeee 12 3 6 TO SELECT CLEAR ONE MAN ZONE TEST 7 8 ROUTINE TESTING AND MAINTENANCE 00 13 Sif TOSELECTCLEAR ONE MAN SOUNDER baa USER RESPONSIBILITIES sce ccccicssceseecesversiecdeaeess 13 3 8 TO ENABLE DISABLE DELAY MODE 8 10 PRECEPT ISOLATE DE ISOLATE TEST MODE 39 To OVERRIDE THE DELAY MODE 8 SELECT FLOWCHART 000ceccccee
10. RESET EROM THERE ARRANGE FOR Gonoirion PRESS RESET ALTERNATNE FIRE DETECTION MEASURES DISABLEMENT AND TEST 1 PRESS SELECT ON OFF THE LED WILL ILLUMINATE 2 SELECT THE ZONE OR OUTPUT USING t AND J THE FAULT LED WILL PULSE 3 PRESS DISABLE OR TEST 4 TO RE ENABLE SELECT THE ZONE OR OUTPUT AND PRESS ENABLE Access Controls Keyswitch 0 Controls Locked 1 Controls Unlocked Switch Functionality Button Availability Description Evaeuate Operates all sounders continuously and lights the Evacuated LED Wharteontralaare unioeked adjacent the button until the silence button is operated Following a fire alarm condition 1st operation stops sounders The General Fire LED and the Zonal fire LED will change from flashing to steady 2nd operation restarts the previously silenced sounders Silence Resound Alarms When controls are unlocked Clears the panel display resets the zones outputs and operates the Pesel reset relay When controls are unlocked and if silence before reset is configured alarms silence switch has been operated 1 Press to stop the buzzer sounding in fire or fault conditions Silence Buzzer 2 In 2 Stage Delay Mode with stage 1 delay running press to start stage 2 delay otherwise all delayed outputs operate when Stage 1 timer times out When controls are locked or unlocked When the panel is in the fire condition and the delay is running Controls are
11. Written by RKP Checked by AJC Approved by JBJ Control Equipment Limited ce Precept Fire Detection Alarm Panel i and Precept Repeater User Operation Manual Document Number Prec en User Rev 2 Page 1 of 13 22 12 09 Written by RKP Checked by AJC List Of Contents 1 PRECEPT USER OPERATION FIRE AND FAULT 3 10 TO EXTEND THE DELAY FROM 1 STAGE TO CONDITIONS cassie cease sivsestacocaccolsoaesniudvnchouersdt 3 BF STAGE neaiski padisini aai 9 1 1 F A FIRE IS DETECTED o n 3 3 11 SILENCING THE ALARMS DURING THE DELAY 9 1 2 TO SILENCE THE FIRE ALARM SOUNDERS 3 3 12 RESOUNDING THE ALARMS AFTER THE DELAY Fo ES BE N CE LEE AUERIFGOUNDERS ALARMS PREVIOUSLY SILENCED e 0 0 0 9 AFTER THEY HAVE BEEN SILENCED 0000 3 4 USER OPERATING INSTRUCTIONS FOR OPTIONAL 1 4 TO RESET THE PANEL FROM A FIRE ALARM a 3 CLOCK MODULE PEI TARRPES TIELT IAT ATTILIO ATAT EYII TLT 9 1 5 TO OPERATE THE FIRE ALARM SOUNDERS IN 4 1 TO DISPLAY ALARM EVENT COUNT ET EAT 9 EVACUATE MODE cesescesesecescecececeseeeeeereees 3 4 2 TOACCESS THE USER CLOCK MODULE EDIT 1 6 IF A FAULT IS DETECTED a e a a a aa 3 FUNCTIONS E E PIATTA ETEESI OTETA RTTE 9 1 7 TO SILENCE THE BUZZER 3 5 Precept REPEATER PANEL USER OPERATION 2 PRECEPTEYUSER INDICATIONS 4 FIRE AND FAULT CONDITIONS seeeeeeeeees 10 Di USER INDICATIONS SHOWING OPTIONAL 5 1 IF A FIRE IS DETECTED ational 10 CLOCK MODULE soy ti
12. ble the Delay Mode o The Delay On Off LED will clear e To quit delay mode selection o Set the Access Controls Keyswitch back to position 0 to lock the controls 3 9 To Override the Delay Mode e When the Delay is running o The Delay On Off LED will flash o The general Fire and zone fire LEDs will flash o The panel buzzer will operate e Press the Delay On Off Override button while the Delay On Off LED is flashing to override the delay allowing all delayed outputs to operate immediately Page 8 of 13 22 12 09 Written by RKP 3 10 To Extend the Delay from 1 stage to 2 Stage e When the panel is configured to the two stage delay mode and before 60 seconds has elapsed since the fire alarm triggered o Press the Silence Buzzer button o The Silence Buzzer button LED will light Q The buzzer will silence a The 2 stage delay will start 3 11 Silencing the Alarms During the Delay e Turn the Access Controls Keyswitch on the panel door to position 1 e Press the Silence Alarms Resound button o The General Fire LED and the Zone Fire LED become steady o The sounders will not operate after the delay has timed out e Set the Access Controls Keyswitch back to position 0 to lock the controls 3 12 Resounding the Alarms after the Delay Alarms previously silenced e Turn the Access Controls Keyswitch on the panel door to position 1 e Press the Silence Alarms Resound
13. e general Disablement LED will be cleared if no other disablements are present e To quit the disable enable mode o To exit the Select Mode press the Select On Off button o The Select On LED will clear o The cursor indication will clear o Set the Access Controls Keyswitch back to position 0 to lock the controls 3 3 To Disable Enable the Fire Routing Output e To Access disable enable mode o Turn the Access Controls Keyswitch on the panel door to position 1 o Press the Select On Off button to enter the Select Mode o The Select On LED will light o The cursor indication will pulse the yellow Zone 1 fault disabled test LED e To select the Fire Routing Output o Use the Select button to move the pulsed cursor indication up through the fault LEDs until it pulses the Fire Routing Fault Disabled LED The Select button moves the cursor down e To disable the Fire Routing Output o Press the Disable button to disable the Fire Routing Output o The Fire Routing Fault Disabled LED will change to the On flash indication while the cursor is on it changing to steady if the cursor is moved o The general Disablement LED will light e To enable the Fire Routing Output o Press the Enable button to enable the Fire Routing Output o The Fire Routing Fault Disabled LED will change to the Off flash indication while the Page 6 of 13 22 12 09 Written by RKP Checked by AJC O O 3 4
14. e relevant zone Fire LED will indicating the location of the fire o If the Delay is OFF Delay LED off Q The Fire Routing output and LED will operate immediately flash Q The Fire Alarm sounders will operate immediately Q The Fire Protection output will operate immediately o If the Delay is ON Delay LED flashing Q The Fire Routing output and LED will operate after a delay if configured for delayed operation Q The Fire Alarm sounders will operate after a delay if configured for delayed operation Q The Fire Protection output will operate after a delay if configured for delayed operation Locate the source of the fire alarm an LED will be visible on the detector which has been activated To Silence the fire alarm sounders Turn the Access Controls Keyswitch on the repeater door to position 1 Press the Silence Alarms Resound button once only The fire alarm sounders will become silent The General Fire LED and the Zone Fire LED will become steady Set the Access Controls Keyswitch back to position 0 to lock the controls To Resound the fire alarm sounders after they have been silenced Turn the Access Controls Keyswitch on the repeater door to position 1 Press the Silence Alarms Resound button once only Set the Access Controls Keyswitch back to position 0 to lock the controls To Reset the panel amp repeater s from a Fire Alarm After the fire has been
15. e test condition enabling normal operation of the selected zone o The zone fault disabled LED will change to the Off flash indication while the cursor is on it changing to off if the cursor is moved on o The general Test LED will be cleared if no other circuits are in the test condition e To quit the zone test selection mode o To exit the Select Mode press the Select On Off button o The Select On LED will clear o Thecursor indication will clear o Set the Access Controls Keyswitch back to position O to lock the controls 3 7 To Select Clear One Man Sounder Test e To access test selection mode o Turn the Access Controls Keyswitch on the panel door to position 1 o Press the Select On Off button to enter the Select Mode o The Select On LED will light o The cursor indication will pulse the yellow Zone 1 fault disabled test LED e To select the sounders o Use the Select t button to move the pulsed cursor indication up through the fault LEDs until it pulses the Sounder Fault Disabled and Sounder Test LEDs The Select button moves the cursor down e To activate the sounder test o Press the Test button to start the sounder test o The Sounder Test LED will change to the On flash indication while the cursor is on it changing to steady if the cursor is moved o The general Test LED will light o The sounders will operate for 2 seconds every 15 seconds until the test mode is
16. een D N ON and D N OFF e To set Current Time Press SELECT to enter current Time Set Display HH MM SS Time Set HH flashing Press ENABLE or DISABLE to change HH to desired value 00 to 23 Press SELECT Time Set Display HH MM SS Time Set MM flashing Press ENABLE or DISABLE to change MM to desired value 00 to 59 Press SELECT Time Set Display HH MM SS Time Set SS flashing Press ENABLE or DISABLE to reset the SS value to zero Press SELECT Time Set Display to exit to Day Night mode On Off Set Display D N ON D N OFF Change or Change Pressing SELECT repeats the cursor display changes as above Pressing SELECT f repeats the cursor display changes as above in reverse e To exit Clock Module Menu Press SELECT ON OFF Module switches off the LCD Backlight and exits configuration mode Normal Time Display HH MM SS HH MM SS or D N ON D N OFF Page 9 of 13 On completion of editing return the Access Control Keyswitch to position 0 22 12 09 Written by RKP Checked by AJC 5 Precept Repeater Panel User Operation e The General Fire LED and the Zone Fire LED 5 1 5 2 5 3 5 4 Document Number Prec en User Fire and Fault Conditions If a fire is detected On the Precept Repeater Panel o The general Fire LED will flash and the buzzer will sound o Th
17. eeseeeeeceeeeseeaeas 13 Danger This equipment contains hazardous voltages that can cause death serious personal injury or equipment damage This equipment contains no user serviceable parts Refer all maintenance to suitably qualified personnel Document Number Prec en User Rev 2 Page 2 of 13 22 12 09 Written by RKP Checked by AJC 1 1 1 1 2 1 3 Document Number Prec en User Precept User Operation Fire and Fault Conditions If a fire is detected On the Precept Fire Alarm Panel o The general Fire LED will flash and the buzzer will sound o The relevant zone Fire LED will indicating the location of the fire o If the Delay is OFF Delay LED off Q The Fire Routing output and LED will operate immediately flash OQ The Fire Alarm sounders will operate immediately Q The Fire Protection output will operate immediately o If the Delay is ON Delay LED flashing Q The Fire Routing output and LED will operate after a delay if the Fire Routing fault disabled LED is illuminated Q The Fire Alarm sounders will operate after a delay if Sounder fault disabled LED is illuminated Q The Fire Protection output will operate after a delay if Fire Protection fault disabled LED is illuminated Locate the source of the fire alarm an LED will be visible on the detector which has been activated To Silence the fire alarm sounders Turn the Access Controls Ke
18. eneral Fault LED will flash One or more fault LEDs will flash identifying which element of the system is faulty When the fault is corrected the fault indication will clear automatically unless the panel is configured to latched fault mode in which case operating the Reset button will clear the fault indication To Silence the Buzzer Press the Silence Buzzer button The Silence Buzzer button LED will light The buzzer will silence 22 12 09 Written by RKP Checked by AJC 2 Precept User Indications This section gives an overview of the functions available to the end user 2 1 User Indications showing optional Clock Module General Indicator Section Indicator Description porta Operating Condition Power Supply On Green llluminates Steady for Mains or Standby power On Fi Flashes on any new fire alarm condition changing to a steady ire Red ST indication on operation of Silence Alarms Fire Routing Active Red llluminates Steady when the Fire Routing Output is active General Fault Yellow Flashes for any fault condition Power Supply Fault Yellow Flashes for mains or standby power supply charge fault System Fault Yellow llluminates Steady to indicate Microcontroller or Memory Failure Flashes to indicate Engineer s Configuration Mode active Earth Fault Yellow Flashes for any positive or negative power supply earth fault Fuse Fault Yellow Flashes fo
19. extinguished turn the Access Controls Keyswitch on the repeater door to position 1 Press the Reset button Rev 2 5 5 5 7 Page 10 of 13 will clear Set the Access Controls Keyswitch back to position 0 to lock the controls To operate the fire alarm sounders in Evacuate Mode Turn the Access Controls Keyswitch on the repeater door to position 1 Press the Evacuate button The Evacuate LED will light and the repeater buzzer will operate All fire alarm sounders will operate Press the Silence Resound Alarm button to silence the fire alarm sounders and clear the Evacuate LED Set the Access Controls Keyswitch back to position 0 to lock the controls If a fault is detected The repeater buzzer will sound The General Fault LED will flash One or more fault LEDs will flash identifying which element of the system is faulty When the fault is corrected the fault indication will clear automatically unless the panel is configured to latched fault mode in which case operating the Reset button will clear the fault indication To Silence the Buzzer Press the Silence Buzzer button The Silence Buzzer button LED will light The buzzer will silence 22 12 09 Written by RKP Checked by AJC Approved by JBJ 6 Precept Repeater Panel Operation 16 zone panel shown General Indicator Section Indicator De
20. f the cursor is moved on o The general Disablement LED will be cleared if no other disablements are present e To quit the disable enable mode o To exit the Select Mode press the Select On Off button o The Select On LED will clear o The cursor indication will clear o Set the Access Controls Keyswitch back to position 0 to lock the controls 3 2 To Disable Enable all Sounders e To Access disable enable mode o Turn the Access Controls Keyswitch on the panel door to position 1 o Press the Select On Off button to enter the Select Mode o The Select On LED will light o The cursor indication will pulse the yellow Zone 1 fault disabled test LED e To select the sounders o Use the Select button to move the pulsed cursor indication up through the fault LEDs until it pulses the Sounder Fault Disabled and Document Number Prec en User Rev 2 Sounder Test LEDs The Select button moves the cursor down e To disable the sounders o Press the Disable button to disable the sounders o The Sounder Fault Disabled LED will change to the On flash indication while the cursor is on it changing to steady if the cursor is moved o The general Disablement LED will light e To enable the sounders o Press the Enable button to enable the sounders o The Sounder Fault Disabled LED will change to the Off flash indication while the cursor is on it changing to off if the cursor is moved on o Th
21. ges to steady when Changes to OFF when Changes to steady cursor is removed cursor is removed when cursor is If Sounders then Sounder removed TEST LED is ON L t 4 4 N a oN AN kort co P uUa Document Number Prec en User Rev 2 Page 13 of 13 22 12 09
22. k Module Optional Jser SE NCHONS Access Controls Keyswitch 0 Controls Locked 1 Controls Unlocked Showing time and Day Night off Back light flashes for Clock Module fault Zone Location Indications PEF Indication np Indicator Description Colour Operating Condition User Generated Zone Flashes when zone is in a fire condition turning to steady on Red l Location Text operation of Silence Alarms User Generated Zone Flashes when zone is in a fault condition llluminates steady when Yellow mae Location Text zone is disabled or in test Document Number Prec en User Rev 2 Page 4 of 13 22 12 09 Written by RKP Checked by AJC 2 2 User Controls showing optional Clock Module FIRE EVACUATE FIRE ROUTING ACTIVE GENERAL FAULT RESOUND ALARMS POWER SUPPLY FAULT SYSTEM FAULT RESET EARTH FAULT FUSE FAILED SILENCE REPEATER FAULT BUZZER SOUNDER FAULT DISABLED ONOFF Tk rf SOUNDER TEST ONOFRI i FIRE PROTECTION FAULT DISABLED SELECT FIRE ROUTING FAULT DISABLED ee FAULT ROUTING FAULT DISABLED O O O O O O O O O O O O O O 10000000000000000 0000000000000000 POWER SUPPLY ON i ZONE LOCATION ZONE LOCATION 0000000000000000 0000000000000000 T FbeTenune THE cause Gere AULT 2 PRESS SILENCE BUZZER 5 CALL YOUR SERVICE REOURED FIRE DALL ENGINEER SO SILENCE ALARMS SvsreM raver D N OFF PRESS SLENGE ALARNS THE PANES E NOPERATIE ETO
23. locked or unlocked 1 Press once to Enable the delay mode lighting the adjacent delay on Delay LED Press again to disable the delay mode and turn off the LED On Off Override 2 Overrides the delay when delay is running All delayed outputs will operate immediately 1 When controls are unlocked and delay period is set to a value gt 0 2 When the panel is in the fire condition and the delay is running Enables the User select feature Select t Select for selection of Select On Off zones or outputs for disablement re enablement also Day Night On Off selection and setting current time on Clock Module when fitted When controls are unlocked Press to illuminate all LEDs on the display and operate the buzzer All Test Display indications remain active for approx 5 seconds after button release Also displays alarm count on Clock Module when fitted When controls are locked or unlocked Press to clear the disablement or test condition on a zone or output When controls are unlocked the Select switch has been operated Enae selected via the User Select feature and a zone or output has been selected Disable Press to disable a zone or output selected via the User Select feature As above Press to initiate the One Man Test on sounders or zones as selected Test As above via the User Select feature Used to scroll the cursor indication through the zone and output fault LEDs on the display to select a
24. on Fault Disabled LED will change to the Off flash indication while the cursor is on it changing to off if the cursor is moved on The general Disablement LED will be cleared if no other disablements are present To quit the disable enable mode To exit the Select Mode press the Select On Off button The Select On LED will clear The cursor indication will clear Set the Access Controls Keyswitch back to position 0 to lock the controls To Select Clear One Man Zone Test To access test selection mode Turn the Access Controls Keyswitch on the panel door to position 1 Press the Select On Off button to enter the Select Mode The Select On LED will light The cursor indication will pulse the yellow Zone 1 fault disabled test LED To select the zone to be tested Use the Select button to move the pulsed cursor indication down through the fault LEDs until it pulses on the required zone The Select t button moves the cursor up 22 12 09 Written by RKP Checked by AJC e To apply the test mode to the selected zone o Press the Test button to activate the test condition on the selected zone o The zone fault disabled LED will change to the On flash indication while the cursor is on it changing to steady if the cursor is moved on o The general Test LED will light e To clear the test mode on the selected zone o Press the Test button again or press the Enable button to clear th
25. r any auxiliary supply fuse failure Repeater Fault Yellow Flashes for any Repeater fault or repeater communication fault Sounder Fault Disabled Yellow Flashes for any sounder fault Steady for sounders disabled Sounder Test Yellow llluminates Steady while sounder walk test is active Fire Protection Yellow Flashes for a fault on the Fire Protection Output Steady when Fire Fault Disabled Protection Output is disabled Fire Routing Yellow Flashes for a fault on the Fire Routing Output Steady when Fire Fault Disabled Routing Output is disabled Fault Routing Yellow Flashes for a fault on the Fault Routing Output Steady when Fault Fault Disabled Routing Output is disabled POWER SUPPLY ON FIRE FIRE ROUTING ACTWE GENERAL FAULT POWER SUPPLY FAULT SYSTEM FAULT EARTH FAULT FUSE FAILED REPEATER FAULT SOUNDER FAULT DISABLED SOUNDER TEST FIRE PROTECTION FAULT DISABLED FIRE ROUTING FAULT DISABLED FAULT ROUTING FAULT DISABLED O O O O O O O O O O O O O O EVACUATE SILENCE RESOUND ALARMS RESET SILENCE BUZZER DELAY ON OFF OVERRIDE SELECT ON OFF ZONE LOCATION ZONE LOCATION TEST DISPLA ENABLE DISABLE 10000000000000000 0000000000000000 10000000000000000 0000000000000000 T DISABNEMENT AND TEST T DETERMINE THE CAUSE OF THE FAULT 2 PRESS SILENCE BUZZER 3 CALL YOUR SERVICE T THE RED ZONE INDICATOR WILL PULSE SHOWING THE PRESS ENABLE Cloc
26. scription gece Operating Condition Power Supply On Green Steady indication for Mains or Standby power On Fi Flashes on any new fire alarm condition changing to a steady ire Red DOE indication on operation of Silence Alarms Fire Routing Active Red Steady indication when the Fire Routing Output is active General Fault Yellow Flashes for any fault condition Power Supply Fault Yellow Flashes for mains or standby power supply charge fault System Fault Yellow Steady indication to indicate Microcontroller Failure General Test Yellow Steady indication when the zone or sounder test is active General Disablement Yellow Steady indication whilst a zone or output is disabled C ore Flashes for a communications failure between the fire panel and ommunications Fault Yellow repeater Sounder Fault Disabled Yellow Flashes for any sounder fault Steady for sounders disabled Sounder Test Yellow Steady indication while sounder walk test is active Fire Protection Yellow Flashes for a fault on the Fire Protection Output Steady when Fire Fault Disabled Protection Output is disabled Fire Routing Yellow Flashes for a fault on the Fire Routing Output Steady when Fire Fault Disabled Routing Output is disabled Fault Routing Yellow Flashes for a fault on the Fault Routing Output Steady when Fault Fault Disabled Routing Output is disabled POWER SUPPLY ON ZONE LOCATION FIRE EVACUATE FIRE ROUTING ACTIVE SILENCE RESOUND ALARMS GENER
27. yswitch on the panel door to position 1 Press the Silence Alarms Resound button once only The fire alarm sounders will become silent The General Fire LED and the Zone Fire LED will become steady Set the Access Controls Keyswitch back to position 0 to lock the controls To Resound the fire alarm sounders after they have been silenced Turn the Access Controls Keyswitch on the panel door to position 1 Rev 2 1 4 1 5 1 7 Page 3 of 13 Press the Silence Alarms Resound button once only Set the Access Controls Keyswitch back to position 0 to lock the controls To Reset the panel from a Fire Alarm After the fire has been extinguished turn the Access Controls Keyswitch on the panel door to position 1 Press the Reset button The General Fire LED and the Zone Fire LED will clear Set the Access Controls Keyswitch back to position 0 to lock the controls To operate the fire alarm sounders in Evacuate Mode Turn the Access Controls Keyswitch on the panel door to position 1 Press the Evacuate button The Evacuate LED will light and the panel buzzer will operate All fire alarm sounders will operate Press the Silence Resound Alarm button to silence the fire alarm sounders and clear the Evacuate LED Set the Access Controls Keyswitch back to position 0 to lock the controls If a fault is detected The panel buzzer will sound The G
28. zone or output for disablement or test LED illuminated when Select Mode is active Also scrolls through Clock Module menu when fitted Select t Select When controls are unlocked and the Select switch has been operated Document Number Prec en User Rev 2 Page 5 of 13 22 12 09 Written by RKP Checked by AJC Approved by JBJ 3 Precept User Controls Disablement and Test Conditions 3 1 To Disable Enable any Zone or Zones e To Access disable enable mode o Turn the Access Controls Keyswitch on the panel door to position 1 o Press the Select On Off button to enter the Select Mode o The Select On LED will light o The cursor indication will pulse the yellow Zone 1 fault disabled test LED e To select the zone o Use the Select button to move the pulsed cursor indication down through the fault LEDs until it pulses the required zone The Select 1 button moves the cursor up e To disable the selected zone o Press the Disable button to disable the selected zone o The zone fault disabled LED will change to the On flash indication while the cursor is on it changing to steady if the cursor is moved on o The general Disablement LED will light e To enable the selected zone o Press the Enable button to enable the selected zone o The zone fault disabled LED will change to the Off flash indication while the cursor is on it changing to off i