IFS MC250-1T/1S User Manual
Contents
1. Step 5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection Step 6 Insert one side of Category 5 cables into the Industrial Fast Ethernet Switch Ethernet port RJ 45 port and the other side to the network device Ethernet port RJ 45 port ex Switch PC or Server The UTP port RJ 45 LED on the Industrial Fast Ethernet Switch will light up when the cable is connected to the network device Please refer to the LED Indicators section for LED light meaning Step 7 Insert fiber cable from the MC250 1T 1S to the fiber network TX RX must be paired at both ends The optical port LED on the MC251 1T 1S will illuminate when the connection is established with network device Please refer to the LED Indicators section for LED light meaning Step 8 When all connections are set up and the LEDs illuminate the installation is completed IFS MC250 1 1S User Manual 13 Switch Operation Address Table The Industrial Fast Ethernet Switch is implemented with an address table This address table is composed of many entries Each entry is used to store the address information of each node in the network including MAC address Port No etc This information comes from the learning process of the Industrial Fast Ethernet Switch Learning When one packet comes from any port of the Industrial Fast Ethernet switch the Industrial Fast Ethernet Switch will record the source address port no and other related infor
2. Brown SIDE 1 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown 12345678 SIDE1 12345678 SDE2 Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network 19 IFS MC250 1T 1S User Manual Contacting Technical Support Contact technical support if you encounter any difficulties during this installation Please make sure you have the requested diagnostic or log files ready before you contact us by phone or go to www interlogix com customer support Technical Support Europe Middle East and Africa W Select Contact Us at www utcfssecurityproducts eu North America T 1 855 286 8889 E _ techsupport interlogix com Australia E _ techsupport interlogix au 20 IFS MC250 1T 1S User Manual
3. disconnecting IFS MC250 1T 1S User Manual 7 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below Inserting the wires the MC250 1T 1S will detect the fault status of the power failure and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts 3 4 5 6 1 2 Note The wire gauge for the terminal block should be in the range between 12 24 AWG The alarm relay circuit accepts up to 30V max 3A current 8 IFS MC250 1T 1S User Manual Mounting Installation This section describes how to mount the MC250 1T 1S and make connections to it Please read the following section and perform the procedures in the order presented Note In the installation steps below this Manual uses the IFS 8 Port Industrial Gigabit Switch GE DSGH 8 as an example However the steps for any IFS Industrial Switch amp Industrial Media Converter are similar Mounting to a DIN Rail The DIN Rail kit comes assembled on the MC250 1T 1S out of the box Please refer to following figures to install the device on a DIN Rail IFS MC250 1T 1S User Manual 9 1 Lightly press down and push the bottom of the DIN Rail connector mount into the track lL 2 Check that the DIN Rail connector mount is tightly mounted on the track 3 Please refer to f
4. or in curb side traffic control cabinets The feature of operating temperature range of 40 to 75 Degrees C coupled with hazardous location certification allows the media converter to be placed in almost any location The MC250 1T 1S is packaged in a compact IP 30 standard metal enclosure that allows either DIN or panel mounting for efficient use of cabinet space The media converter provides an integrated power supply with a wide range of voltages 12 to 48V DC for worldwide operability or dual redundant reversible polarity 24V DC and 48V DC power supply inputs for high availability applications requiring dual or backup power inputs The MC250 1T 1S provides 1 x 10 100Base TX and 1 x 100Base FX optic fiber SFP interface IFS MC250 1T 1S User Manual 3 With the Fast Ethernet SFP interface the MC250 1T 1S extends the transmission distances from 220m to 70Km The actual distance is defined by the Fast Ethernet SFP module selected The IFS family of Fast Ethernet SFP modules comes with one of the following models The following list shows the available Modules for MC250 1T 1S a anes a Leah Mamaa UE Ben Fa moma US 4 IFS MC250 1T 1S User Manual Front Panel The figure below shows the Front Panel of the MC250 1T 1S IFS MC250 1 1S User Manual 5 LED Indicato
5. 3 interlogix T MC250 1T 1S User Manual P N 1072573 REV 00 06 ISS 30JAN13 2013 UTC Fire 8 Security Americas Corporation Inc Interlogix is part of UTC Climate Controls amp Security a unit of United Technologies Corporation All rights reserved The IFS MC250 1T 1S and logo are trademarks of United Technologies Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products Use this product only for the purpose it was designed for refer to the data sheet and user documentation for details For the latest product information contact your local supplier or visit us online at www interlogix com UTC Fire amp Security Americas Corporation Inc 2955 Red Hill Avenue Costa Mesa CA 92626 5923 USA EU authorized manufacturing representative UTC Fire amp Security B V Kelvinstraat 7 6003 DH Weert The Netherlands CE Grass This equipment has been tested and found to comply with the limits for 8 Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications You are cautioned that any changes
6. Indicators 6 Converter Top Panel 7 Wiring the Power Inputs 7 Wiring the Fault Alarm Contact 8 Mounting Installation 9 Installation Steps 13 Switch Operation 14 Troubleshooting 16 Specifications 17 RJ45 Pin Assignments 8 Contacting Technical Support 20 IFS MC250 1T 1S User Manual Overview This section describes the functionalities of the IFS MC250 1T 1S Industrial Media Converter s components and guides how to install it on the desktop Basic knowledge of networking is assumed Please read this chapter completely before continuing In the following section the term Industrial Media Converter means the IFS MC250 1T 1S Package Contents Check the contents of your package for the following parts Industrial Media Converter x1 User s Manual x1 DIN Rail Kit x 1 Wall Mount Kit x 1 If any of these items are missing or damaged please contact your distributor or IFS sales rep immediately If possible retain the original carton and packaging material in case of need to return the product for repair replacement IFS MC250 1T 1S User Manual 1 Product Features Physical Port O 1 Port 10 100Base TX RJ 45 O 1 Port 100Base FX SFP slot Distance depends on SFP module Industrial Design O Slim type IP 30 metal case O 40 to 75 Degree C operating temperature DIN rail and wall mount design O 12 to 48V DC redundant power with polarity reverse protection and detachable terminal block connectors
7. chapter contains information to help resolving issues If the Industrial Fast Ethernet Switch is not functioning properly make sure the device was set up according to instructions in this manual The Link LED is not light Solution Check the cable connection of the Industrial Fast Ethernet Switch Performance is bad Solution Check the speed duplex mode of the partner device The Industrial Fast Ethernet Switch is operating at Auto negotiation mode by default and if the partner is set to half duplex then the performance will become bad Link LED is illuminated but the traffic is irregular Solution Check that the attached device is not set to dedicate full duplex Some devices use a physical or software switch to change duplex modes Auto negotiation may not recognize this type of full duplex setting Why does the Industrial Fast Ethernet Switch not connect to the network Solution Check every port LED on the Industrial Fast Ethernet Switch Try another port on the Industrial Fast Ethernet Switch to make sure the cable is installed properly while making sure the cable is the right type Turn off the power and turn on the power again after waiting for awhile 16 IFS MC250 1T 1S User Manual Specifications Product MC250 1T 1S Hardware Specification 10 100Base TX Port 100Base FX Port 1 RJ 45 Auto MDI MDI X port 1 SFP Slot Fiber Port Type Cable Distance Optical Frequency Launch Power dBm Receive S
8. ensitivity dBm Maximum Input Power dBm Dimension W x D x H Weight Installation Maximum Frame Size Deprends by SFP module 135mm x 85mm 32mm 4309 DIN rail kit and wall mount ear 1522bytes packet size Back pressure for half duplex IEEE 802 3x Pause Por conta Frame for full duplex Enclosure 1P 30 Slim Type Metal Case System Power 1 Green Power 2 Green Fault Green 1x copper port EARNE e 10 100 Green LNK ACT Green 1 x 100FX port gt 100 Green gt LNK ACT Green pee 12 to 48V DC Redundant power with polarity reverse protection function Power Consumption 3 watts 10BTU maximum IFS MC250 1T 1S User Manual 7 When connecting to other Ethernet equipment such as a Router Bridge Switch or Hub please refer to that device s Technical Manual RJ45 Pin Assignments 10 100Mbps 10 100Base TX MDI MDI X Contact Media Dependant Media Dependant Interface Interface Cross 1 Tx transmit Rx receive 2 Tx transmit Rx receive 3 Rx receive Tx transmit 4 5 Not used 6 Rx receive Tx transmit 7 8 Not used RJ45 Cable Drawing The following figure shows the pin allocation and color of a straight cable and connection of a crossover cable 18 IFS MC250 1T 1S User Manual SWE 1 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8
9. for master and slave power O Supports EFT protection 6000V DC for power line O Supports 6000V DC Ethernet ESD protection Data Communication O Complies with the IEEE 802 3 IEEE 802 3u Fast Ethernet standard O Auto MDI MDI X detection and Auto negotiation with Half Duplex Full Duplex modes for 10 100Base TX RJ 45 port O Store and Forward switching architecture O Features Store and Forward mode with wire speed filtering and forwarding rates O Prevents packet loss with back pressure Half Duplex and IEEE 802 3x PAUSE frame flow control Full Duplex Support to handle up to 1522bytes packet size CSMA CD protocol Automatic source address learning and aging ooo 2 IFS MC250 1T 1S User Manual Installation This section describes the functionalities of the Industrial Fast Ethernet Switch s components and guides how to install it on the desktop Basic knowledge of networking is assumed Please read this chapter completely before continuing In the following section the term Industrial Fast Ethernet Switch means the MC250 1T 1S Product Description The MC250 1T 1S is an industrially hardened media converter which is specially designed to operate from 40 to 75 C temperature The MC250 1T 1S provides highly reliable and stable operations for demanding of environments The MC250 1T 1S provides a high level of immunity to electromagnetic interference and heavy electrical surges typical of environments found on plant floors
10. mation in the address table This information will be used to decide either forwarding or filtering for future packets Forwarding amp Filtering When one packet comes from another port of the Industrial Fast Ethernet Switch it will also check the destination address besides the source address learning The Industrial Fast Ethernet Switch will lookup the address table for the destination address If not found this packet will be forwarded to all the other ports except the port which this packet came in And these ports will transmit this packet to the network it s connected to If found and the destination address is located at a different port from this packet comes in the Industrial Fast Ethernet Switch will forward this packet to the port where this destination address is located according to the information from address table But if the destination address is located at the same port with this packet comes in then this packet will be filtered Store and Forward Store and Forward is one type of packet forwarding techniques A Store and Forward Industrial Switch stores the incoming frames in an internal buffer and checks for any errors 14 IFS MC250 1T 1S User Manual from the frames before transmission Lack of error packet occurrence is important for an efficient and stable network The Industrial Fast Ethernet Switch scans the destination address from the packet header searches the routing table provided for the incoming por
11. ollowing procedures to remove the MC250 1T 1S from the track 10 IFS MC250 1T 1S User Manual 4 Lightly press down and pull the bottom of DIN Rail connector mount to remove it from the track Mounting to a Wall To install the MC250 1T 1S on the wall please follow the instructions described below 1 Loosen the screws to remove the DIN Rail from the Media Converter IFS MC250 1T 1S User Manual n 2 Place the wall mount plate on the rear panel of the MC250 1TAS 3 Assemble the wall mount plate on the MC250 1T 1S 4 Use the hook holes at the corners of the wall mount plate to hang the MC250 1T 1S on the wall 12 IFS MC250 1T 1S User Manual Installation Steps Step 1 Unpack the Industrial Fast Ethernet Switch Step 2 Check that DIN Rail is screwed on the Industrial Fast Ethernet Switch Please refer to the DIN Rail Mounting section for DIN Rail installation If you want to wall mount the Industrial Fast Ethernet Switch then please refer to Wall Mount Plate Mounting section for wall mount plate installation Step 3 To install the Industrial Fast Ethernet Switch on the DIN Rail track or wall please refer to the Mounting Installation section Step 4 Power on the Industrial Fast Ethernet Switch Please refer to the Wiring the Power Inputs section for power input The power LED on the Industrial Fast Ethernet Switch will light up Please refer to the LED Indicators section for meaning of LED lights
12. or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Notice This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003du Canada 2004 108 EC EMC Directive Hereby UTC Fire amp Security Americas Corporation Inc declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004 108 EC 2002 96 EC WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see www recyclethis info For contact information see our Web site www interlogix com www interlogix com customer support Copyright Trademarks and patents Intended use Manufacturer Certification FCC compliance ACMA compliance Canada European Union directives 5 Contact information Contact support Contents Overview 1 Package Contents 1 Product Features 2 Installation 3 Product Description 3 Front Panel 5 LED
13. rs m System LED Color Function P1 Green Indicates that power 1 is on 2 Green Indicates that power 2 is on Fault Green Indicates either power 1 or power 2 has no power m Per 10 100Base TX Port LED Color Function Indicates that the link through that port is Light successfully established at 100Mbps Link ACT Green Indicates that the Switch is actively sending Blink receiving data over that port m Per 100Base FX Port LED Color Function Indicates that the link through that port is lsuccessfully established at 10 or 100Mbps Light Link Green ACT Indicates that the Switch is actively sending Blink receiving data over that port 6 IFS MC250 1 1S User Manual Converter Top Panel The top panel of the MC250 1T 1S consists of a terminal block connector with two DC power inputs e 1 Ns oo 0 0 0 0 0 0 0 0 0 O O mn me FO LO seaman Wa k Wiring the Power Inputs The 6 contact terminal block connector on the top panel of the MC250 1T 1S is used for two DC redundant powers inputs Please follow the steps below to insert the power wires 1 Insert positive negative DC power wires into the contacts 1 and 2 for POWER 1 or 5 and 6 for POWER 2 0 V2 V2 Input DCI2 48V PWR Faut PWR2 1 1 V2 V2 2 Tighten the wire clamp screws to prevent the wires from
14. t and forwards the packet only if required The fast forwarding makes the switch attractive for connecting servers directly to the network thereby increasing throughput and availability However the switch is most commonly used to segment existing hubs which nearly always improves overall performance Ethernet Switching can be easily configured in any Ethernet network environment to significantly boost bandwidth using conventional cabling and adapters Due to the learning function of the Industrial Fast Ethernet Switch the source address and corresponding port number of each incoming and outgoing packet are stored in a routing table This information is subsequently used to filter packets whose destination address is on the same segment as the source address This confines network traffic to its respective domain reducing the overall load on the network The Industrial Fast Ethernet Switch performs Store and Forward therefore no error packets occur More reliably it reduces the re transmission rate No packet loss will occur Auto negotiation The TP ports on the Industrial Fast Ethernet Switch have built in Auto negotiation This technology automatically sets the best possible bandwidth when a connection is established with another network device usually at Power On or Reset This is done by detecting the modes and speeds at the moment both devices are connected IFS MC250 1T 1S User Manual 15 Troubleshooting This