Home

Operator`s Manual - B&G Equipment Company

image

Contents

1. 34594 34659 34682 34605 18 34605 38 Rod 405 O D x 4 Stainless Steel Setscrew 3 8 x 1 2 Stainless Steel Quick Change Shank for 405 Rod Quick Change Shank for 11 16 Rod Nut for Quick Change Adapter Gasket Buna N Slab Injector Pedal Assembly Slab Injector Pedal Weldment Setscrew 3 8 x 1 Stainless Steel Nut Coneseal Retainer Coneseal 3 pack Quick Change Adapter for 405 Rod Quick Change Adapter for 11 16 Rod
2. Cone Seal Retaining screw Lock knob Foot ram Cone seal Lock bolt Rev 1 05 B amp G Equipment Company 135 Region South Drive Jackson GA 30233 800 544 8811 Termite Tool Repair Kits VERSAGUN REPAIR KIT Order 22067554 22067503 22067514 22067517 Adapter 2 20 Locknut Versagun Seal Versagun VERSATOOL REPAIR KIT Order 22028910 1 1964 VT 622A TN 45 VT 616 VT 621A 1138 SRG and QCG REPAIR KIT 1 34555 V HWN 34516 V 34517 V 34503 V 34506 V 34507 SRG and QCG REPAIR KIT 2 34601 V HWN 34516 V 34517 V 34510 33000090 22060100 22040500 22059500 22060000 22071038 22067536 22067714 22067715 22067740 22067743 22067744 22067536 22067714 22067715 22067728 O Ring Seat gasket holder Hex nut Trigger lock spring Seat gasket Spacer Order 22067848 Hose gasket Gasket Viton O ring PT 6 O ring Viton O ring Viton O ring back up Order 22067748 Hose gasket Gasket Viton O ring PT 6 Valve seat VERSAGUN PROBLEMS AND SOLUTIONS P Gun is leaking at the junction with the soil rod S Remove the soil pipe and tighten the tip to the gun If leak continues loosen and remove the tip clean the exposed end of the Shutoff stem and the white gasket in the center of the tip If leak continues replace the tip the gasket can not be replaced separately P Leaking occurs at the back of the Valve S Loosen the Lock nut 1 4 turn at the
3. Current Manual 06 08 10 TERMITICIDE APPLICATION TOOLS USER S MANUAL equipment company Safety Precautions Connect the tool to the supply hose and be certain the trigger is in the off position before turning on the pump Do not adjust the tip while depressing the valve trigger Before removing the tool from the supply hose be certain to shut off pump and relieve pressure in the hose by depressing the trigger Do not leave the tool unattended when the valve is in the ON position Wear personal protection equipment that protects hands face eyes and mouth Read and follow all label directions on liquid termiticides before making an application Before Starting Inspect the hose hose connections to the valve and the pump discharge pipes and nozzle for signs of wear or damage These parts must be in full working condition for proper application t is recommended that these tools are used at low 25 psi pressure and that liquid termiticides are applied at low pressure B amp G termiticide application tools are designed to deliver liquid to soil and voids beneath concrete slabs and into the cavities in concrete block walls Application Tips 7 16 and 360 spray gal min 7 16 and 180 spray 2 gal min 7 16 and void spray 2 gal min 5 8 and 360 spray 2 gal min Tips are calibrated at 20 psi The 180 tips are designed for directional application align the tip with the orientat
4. Toss P and be the O rings may be worn or cause of a leak Rev 1 05 QCG AND SRG GUN PROBLEMS AND SOLUTIONS P Gun is leaking from the tip around the junction of the Nosepiece and the body of the gun S Remove Nosepiece adapter and inspect the Shutoff valve and the Valve seat gasket Clean the tip of the Shutoff valve and turn over the Valve seat gasket If leaking continues replace the Valve seat gasket QCG Shutoff x ane i valve Viton MEN Viton Gasket Nosepiece adapter P Leaking occurs at the back of the gun around the large brass nut S Tighten the Gland nut at the back of the gun If leaking continues at this site disassemble the gun and replace the gasket and O ring associated with the Gland nut P Leaking occurs around the Pattern adjust sleeve of SRG gun S Remove the Nozzle nut and inspect the O ring remove dirt from around the Nozzle Remove Pattern adjustment sleeve and inspect Viton and Teflon O rings Replace if damaged or worn Note Pattern valve has reversed thread to open SRG Teflon Pattern adjust AU sleeve Viton O ring S a O ring Q Pattern y valve s Nozzleg ys P d Nozzle 6 Viton O ring eras nut i QCG REPACKING KIT 34601 V 1 Valve seat 1 Viton gasket 1 Viton O ring Rev 1 05 VERSAGUN GUN TOOLS PRIOR TO 2005 D Versatool 2000 B V
5. back of the gun this will re set the Shutoff stem to the gasket in the tip If leak continues the Packing screw may have to be removed and the packing replaced Packing screw Packing Tip with gasket Shutoff stem Lock nut Packing screw Copper Packing washer Rev 1 05 VERSATOOL PROBLEMS AND SOLUTIONS P Tool is leaking from the tip S Remove the soil pipe and in the base of the Valve tighten the Seat gasket holder with a 5 32 hex wrench If tool continues to leak remove the Seat gasket holder 5 32 hex wrench and replace the white Seat gasket If tool continues to leak replace O rings on the Valve rod Disassemble the Trigger then remove the Seat gasket holder push the Valve rod out from above Leaking occurs around the soil pipe connection to the Valve Remove the soil pipe and in the base of the Valve tighten the Seat gasket holder with a 5 32 hex wrench If leak continues remove the Seat gasket holder 5 32 hex wrench and replace the white seat gasket P Leaking occurs around the Rod spring at the center of the Valve handle S Replace O rings on the Valve rod Disassemble the Trigger then remove the Seat gasket holder push the Valve rod out from above Seat gasket Seat gaske holder Rod spring Valve rod O rings Valve rod i O rings on Valve rod damaged
6. 22067510 ele seal 10 22058800 00666 6 22067508 Viton Seal i 22040500 Tm 7 22067509 Spring spacer T 8 22067575 Versagun body equipment company 9 22067515 Versagun trigger 13 22059400 Trigger lock F 14 22059500 Trigger lock spring 3 135 REGION SOUTH DRIVE 15 22059600 Trigger lock screw u JACKSON GA 30233 16 22067518 Adapter 12 22055447 Compression spring Toll Free 800 544 8811 17 95144402 Threaded washer uke Phone 676 688 5601 14 22067521 Soft seat adapter Fax 678 688 5633 Kit 22067554 Valve Rebuild Kit www bgequip com PARTS LIST FOR 006 GUNS QCG Gun 4 Parti Description 4 Part Description 10 34310 Valve seat 22 34522 Pivot bolt washer 11 34511 Shutoff valve 23 34590 Q Label 12 34512 Shutoff spring 24 34596 Trigger lock 13 34513 Trigger Asy not shown 25 HWN Gasket 14 34514 Pivot bolt 26 34519 N Lock nut valve stem 15 34515 N Pivot bolt nut 27 34513 A Trigger piece 16 34516 V Gasket 28 34513 B Valve yolk 17 34517 V O ring 29 34513 C Trigger hinge bolt 18 34518 Gland nut 30 34513 D Hinge bolt nut 19 34519 S Valve stem nut 31 34563 Adapter 20 34520 Handle 32 34606 6 Cone Jet Asy not shown 21 34521 Adapter 33 34606 12 Cone Jet Asy not shown Expanded Manual and tools older than 2005 USER amp FE wu S fio 8 MAINTENANCE 2 M MANUAL s Termite Tools amp Equipment B amp G Equipment Company 135 Reg
7. 6 22067501 Tip 2 gpm A Versa Gun 17 22067502 Tip 3 gpm 18 22067503 Adapter 1 2 20 19 22067504 Adapter 1325 Tip Cap 20 22071716 Cone Seal Assembly 21 ACS30 22071776 Foot Ram Weldment 22 1381 22071381 Bolt Lock 23 1380 22071380 Knob Lock 24 1145 22071045 Screw Retaining 830 24 x 25 25 22071715 Seal Cone 26 95122354 Adapter Quick Connect 27 95122356 Socket Quick Connect 28 95122355 Plug Quick Connect 29 1340 22071940 Pipe Slab 7 16 x 40 30 1378 22071378 Pipe Soil 5 8 x 46 31 1312 22071912 Pipe Slab 7 16 x 12 32 22071970 Shaft SlabJet 33 22071950 Valve Check 480 34 22071955 Valve Check SlabJet P M PH HH N HP HH HH WEN P HH ee H HB 4 in 1 Termite Tool 34610 ROBCO TOOLS Prior to 2005 OG Parts List Key Part 1 1 2 3 4 5 6 7 8 9 o Qca 34547 34568 L 34568 5 34868 C2 34571 34573 34576 34583 39 34583 24 Description Quick Change Gun Splashguard Metal for Void Injector Injection tip Laterat 4 Way Stainless Injection tip Sub Slab 5 Upfan Stainless Injection tip Center 2 GPM Stainless Steel Injection tip for 11 16 Rod Stainless Steel Push Handle with Rubber Grip Rod for injector 11 16 x 36 Galvanized 868 405 O D x 39 Stainless Steel Rod 405 O D x 24 Stainless Steel Page 21 34583 4 34588 34611 18 34511 38 GHN HWN 34656 34657
8. 8 7 16 x 40 10 22067904 7 16 x 12 12 22071429 5 8 x 40 15 22060850 Splash guard 15 22060850 Splash guard 22071605 Check Valve not shown for 7 16 Pipes Standard Tip Kit Part Computer Description r Extension Pipes 457 11007457 void 2 gpm 455 11007455 360 5 gpm f Computer Description 454 11007454 360 2 gpm 453 11007453 1805 2 gpm 13 11007460 7 16 x 40 451 11007451 360 2 gpm 14 11007465 5 8 x 40 I OONOQORON 484 486 Versatool Part 1549 1544 VT 618 1 1964 VT 619 VT 621A VT 622A VT 611 VT 609 TN 45 1138 VT 612 VT 615 VT 616 VT 617 1340 Not Shown Order 22071649 22071644 22059700 33000090 22059800 22060000 22060100 22059000 22058800 22040500 22071038 22059100 22059400 22059500 22059600 22070917 22071940 22071950 Description Valve assembly Valve body Spring rod O Ring Valve rod Seat gasket Seat gasket holder Valve trigger Trigger pin Hex nut Spacer Rod screw Trigger lock Trigger lock spring Trigger lock screw Adapter Pipe assembly Check valve assm Check valve fits between parts 17 amp 18 1390 1542 Kit 22071390 22071642 22028910 Tip 6 hole Fan tip 2 gpm Valve rebuild kit Includes 4 6 7 10 11 14 Oma C ani Adjustable Cone Seal Part ACS 1145 1380 ACS30 ACS25 1381 Order 22071775 22071045 22071380 22071776 22071771 22071381 Description Adj
9. c pattern tip 2457 delivers liquid in a straight non directional pattern Tip 454 This 2 gallon per minute tip is intended for applying liquid termiticides in soil around the outside perimeter of buildings using 5 8 inch pipe At 25 psi this tip dispenses liquid in a 360 pattern Tips 450 452 These 1 gallon per minute tips are intended for applying liquid termiticides beneath inside or outside concrete slabs using 7 16 inch pipes At 25 psi tip 450 dispenses liquid in a 360 pattern tip 452 dispenses liquid in a 180 fan arc pattern Tip 455 This 5 gallon per minute tip is intended for use with 5 8 inch pipe for applying liquid fertilizer to to soil around landscape trees and shrubs and for treating the balled root system of nursery stock trees BEFORE STARTING e Inspect all hoses and junctions of the hose to tool and to the pump to be certain all connections are secure and not leaking e These tools are not recommended for use above 25 psi OPERATING INSTRUCTIONS Connecting tool to the pump These tools can be connected to the hose from the pump by using 1 a female quick connect on the pump hose and a male quick connect on the tool Supplied by operator or 2 a hose connected directly from the pump to the valve The thread size of the input port in the valve is 3 8 inch female pipe thread FPT Soil treatments Manufacturer recommendations may include applying liquid termiticide into a trench adjacent to the buil
10. ding foundation and to the soil below the trench adjacent to the foundation and footer The 5 8 inch stainless or galvanized pipe is best suited for soil injection Estimate the depth of soil above the footer to determine the distance the pipe will be inserted into the ground The pipe may easily enter and be removed from the soil while liquid is being applied through the tip Application techniques include treating the trench then pushing the pipe through the treated soil adjacent to the foundation Drill holes in concrete slabs Use 9 16 inch or larger holes for sub slab application with the 7 16 inch pipes Holes that are 1 2 inch may cause the pipe to bind when small pieces of concrete lodge around the pipe The pipe or valve may be damage during removal from a 1 2 inch drill hole Application below concrete slabs Drill 9 16 inch holes through slab and determine the thickness of the slab Secure the Foot ram so that the bottom of the cone seal is an additional 1 inch from the tip as the depth of the slab This will allow for the cone to seal the drill hole and for the tip of the pipe to extend into the void between the concrete slab and soil Application to structural voids The 12 inch long 7 16 inch pipe can be used for treating in shallow voids When the straight tip void tip is used the splash guard should be placed between the void tip adapter and the void tip Orientation of 180 and 360 tips To orient tip 452 and 453 first t
11. ersatoo 480 Soil Rodder 488 B Versatoo 480 TOOLS PRIOR TO 2005 INCLUDES VT480 SLABJET 2000 amp VT 2000 VERSAGUN TERMITE TOOLS Repair Parts List Item Part Computer 5 No No Description Unit PL VGUNS December 12 1997 35 1389 22071389 Tip Slab 3609 1 gpm 6 Hole 1 Iten Part Computer Qty 36 1390 22071390 Tip Slab 360 2 gpm 6 Hole 1 d ch 37 1543 22071643 Tip Slab 1805 1 gpm Fan 1 Description Uni f No No Unit 38 1542 22071642 Tip Slab 180 2 gpm Fan 1 7 39 1594 22071694 Soil 1805 1 gpm Fan 1 L 22067500 Valve Versagun Termite 40 1595 22071695 Tip Soil 190 2 gpm Fan 1 2 22067530 Valve Versagun 200 Al VT 624 22060300 Tip Void i e i 42 VT 630 22060850 Guard Anti Splash 1 x minde xs gun 43 1540 22071640 Adapter Male 1 sort Ed 44 20002001 Body Foam Head 1 eM BREED 45 22051231 Valve Air Check 6 7 22067508 Spring Shutoff 46 20002010 Sereen Foam 1 8 22067509 Spacer Spring 47 20002005 Adapter Foam Slab Pipe 1 3 22067510 Gland Packing 48 20002015 Pipe Foam 7 16 x 16 1 9A 22067517 Washer Sealing not shown 45 22070725 Gauge 0 160 psi 1 10 22067511 Screw Packing S0 728 22058653 Nipple Hex 3 8 NPT 11 22067512 Pin Actuator 53 737 22058662 Strainer 1 12 22067513 Block Actuator 52 22067526 Fitting Garden Hose 1 13 22067514 Locknut 53 22067527 Washer Garden Hose Fitting 1 14 22071285 Plug Pipe 1 8 NPT 35 22067506 Handle Versagun 1
12. g Trigger lock screw Adapter washer Valve rebuild kit Includes 3 5 6 9 11 14 B amp G Equipment Company 135 Region South Drive Jackson GA 30233 800 544 8811 QCG GUN SRG GUN FR Part 34501 SRG AND QCG GUNS Description Nozzle nut 34502 6 Nozzle orifice 34503 V O ring P 14 34504 34505 Adj sleeve Sleeve screw 34506 V O ring P 18 34507 34508 34509 34510 34511 34512 34513 34514 Back up O ring Pattern valve Valve body Valve seat Shutoff valve Shutoff valve spring Trigger assembly Pivot bolt 34515 N Pivot bolt nut Trigger assembly 5 27 30 Gasket O ring Gland nut Valve stem nut Handle 1 2 MPT adapter Pivot bolt washer Label Trigger lock Gasket for QCG gun Lock nut valve stem Trigger piece Valve yolk Trigger hinge bolt Hinge bolt nut Nosepiece Rev 1 05 B amp G Equipment Company 135 Region South Drive Jackson GA 30233 800 544 8811 SERIES 400 TOOLS PIPE SETS EXTENSION PIPES AND TIPS Standard Pipe Set 7 16 1 gpm Tips 450 11007450 360 453 11007452 180 Standard Pipe Set Professional Pipe Set Computer Description Computer Description 22067797 1 8 adapter 6 22067797 1 8 adapter 22067798 3 8 adapter 22067798 3 8 adapter 22067906 5 8 x 40 galvanized 10A 22071427 7 16 x 12 22067912 7 16 x 40 11 2207142
13. ighten the tip to the end of the pipe then loosely tighten the pipe into the base of the valve Orient the tip in the desired position in relation to the valve so that the liquid dispenses toward the treated surface foundation wall then finish tightening the pipe to the valve The 360 tip does not require orientation Application Depress fully the valve trigger to release liquid through the pipe to the tip The trigger can be locked open on the Versatool Model 4410 4415 and 4486 and the Robco QCG Model 4420 and 4425 Do not leave the tool unattended with the locking mechanism engaged CARE AND MAINTENANCE Routine cleaning The tool should be flushed with clean water following every use with liquid termiticides or fertilizer All seat gaskets washers and O rings should be periodically inspected for wear and replaced when necessary Versatool cleaning The valve can be cleaned by using a 5 32 hex wrench and removing the Valve seat gasket holder from the base of the valve Clean any dirt on the Teflon seat gasket in the Holder Replace the gasket if it is worn or damage Depress the trigger on the valve then re insert the gasket holder using the hex wrench Robco QCG cleaning This gun can be cleaned by unscrewing the Nosepiece and removing the black gasket Valve seat Use a soft brush or cloth to clean any dirt on the rounded end of the shutoff valve and clean the gasket Depress the trigger on the gun then replace gasket and
14. ion South Drive Jackson GA 30233 800 544 8811 Phone 678 688 5601 Fax 678 688 5633 Rev 1 05 User s Manual Termite Control Tools p s 5 SAFETY PRECAUTIONS Connect the treating tool to the supply hose before turning on the pump Shut off pump and release pressure in tool before removing supply hose Protect face eyes and mouth during application of liquid under pressure Disconnect the tool from pump hose when changing tips Direct spray tip only at surfaces to be treated with liquid Do not leave the tool unattended with the locking mechanism engaged Follow manufacturer label directions when applying termiticides SUGGESTED USES Models No 410 420 430 486 These treatment tools are intended for use in the distribution of liquid termiticides in areas likely to allow entrance of subterranean termites into a structure They are suitable for treating soil beneath outside concrete slabs garages porches walkways using the 7 16 inch pipes and foot ram and for treating soil around the perimeter of buildings using the 5 8 inch pipe These models do not have the tip shutoff feature and use indoors may result in drips on non target surfaces Refer to insecticide manufacturer labels for end use restrictions on termiticides Models 415 425 435 These tools are intended for use in the distribution of liquid termiticides in areas in areas likely to allow entra
15. ion of the valve so that liquid termiticide will be directed at the foundation wall Application Pipes Rods The Standard and Professional pipe sets include 12 stainless steel 7 16 diameter 40 stainless steel 7 16 diameter 40 stainless steel 5 8 diameter or 40 galvanized steel 5 8 diameter Drill a 9 16 or larger hole for treating beneath concrete slabs with 7 16 pipes using smaller holes will damage the pipe and or the tip Care and Maintenance Flush the valve application pipes rods and tip with clean water regularly Termiticide residue can reduce the operation and accuracy of valves and tips Soil tips should be replaced regularly 2 year cycle insertion into soil can abrade and increase the nozzle opening and the threads on the rod and tip Clean the adapters on the pipes that hand tighten to the valve they can wear when exposed to soil Replace pipes rods that become bent or otherwise damaged Trouble Shooting Problem VERSATOOL Leaking around rod spring where trigger attaches to valve Solution Replace both o rings 433000090 on the valve rod disassemble the trigger and push rod out from above Problem VERSATOOL Leaking at pipe connection to valve Solution Use hex wrench to tighten seat gasket holder or remove and replace seat gasket Problem VERSAGUN Leaking at pipe connection to valve Solution Remove adapter at base of valve pipe connec tion and clea
16. ly QCG Gun is leaking from around the junction of the Nosepiece and the body of the gun Remove Nosepiece adapter and inspect Shutoff valve and Valve seat gasket Clean the tip of the Shutoff valve and turn over the Valve seat gasket If leaking continues replace the Valve seat gasket I OONOOBRWAN lt I o 5 lt VersaGun Valve Order 22067500 22067514 22067513 22067511 22067517 22067510 22067512 22067509 22067514 22071285 22067506 22067516 22067505 22067514 22067515 22024410 22067507 22067503 22067526 22067527 22070725 22067518 22067554 Description Valve assembly Locknut Actuator block Packing screw Sealing washer Packing gland Actuator pin Spring spacer Locknut Pipe plug 1 8 NPT Versagun handle Trigger pin Versagun body Locknut Versagun trigger Shutoff spring Shutoff stem Adapter 1 2 Hose fitting Hose fitting washer 0 160 gauge Adapter washer Valve rebuild kit Includes 1 4 17 Versatool Valve Order 22071649 22071644 22059700 33000090 22059800 22060000 22060100 22059000 22040500 22071038 22058800 22040500 22059100 22059400 22059500 22059600 22067518 22028910 Description Valve assembly Valve body Spring rod O Ring Valve rod Seat gasket Seat gasket holder Valve trigger Hex nut Spacer Trigger pin Hex nut Rod screw Trigger lock Trigger lock sprin
17. n the tip of the shutoff stem and the seat gasket f leaking continues slightly loosen not tighten the lock nut at the top of the valve Problem QCG GUN Leaking from the tip around the junction of the nosepiece and the body of the gun Solution Remove the nosepiece adapter and inspect the shut off valve and the valve seat gasket Clean the tip of the shut off valve and turn over and replace the valve seat gasket in the gun QCG Repair Kit 34601 V Problem QCG GUN Leaking occurs at the back of the gun around the large brass nut Solution Tighten the brass nut gland nut at the back of the gun If leaking continues disassemble the gun and replace the gasket and o ring associated with the gland nut 95138232 Rev 5 10 Perera CERRY STANDARD TIP KIT Part Comp Description 1 451 11007451 360 2 gpm 2 453 11007453 180 2 gpm Versatool 3 454 11007454 36052 gpm 4 457 11007457 void 2 gpm VERSATOOL VALVE 400 SERIES Part Description VERSAGUN VALVE Versagun Valve 11007407 Valve assembly 1 22071644 Valve body 400 SERIES BRAC Hel 9 Line 2 22059700 Spring rod Part Description Ho Valve 11004706 Valve assembly 21410 5 44 88 1 1 1 29103309 110 24 hex nut m ES 7 22059000 IE 3 Actuator pin 4 22067511 Packing screw Se 5
18. nce of subterranean termites into a structure They are suitable for treating soil beneath inside or outside concrete slabs using the 7 16 inch pipes and foot ram and for treating soil around the perimeter of buildings using the 5 8 inch pipe The pipes for these models have tip shutoff and they are suitable for use indoors Refer to insecticide manufacturer labels for end use restrictions Versatool 4410 415 This tool can be used to inject termiticide into perimeter soil and into voids to treat soil beneath concrete slabs It can be fitted with 5 8 and 7 16 pipes and with 1 or 2 gpm tips Tip shut off is a feature of Model 4415 VersaGun 4490 435 This multiple purpose gun can be used for broadcast spraying injecting termiticide into perimeter soil and for treating voids and soil beneath concrete slabs It can be fitted with 5 8 and 7 16 pipes and 1 or 2 gpm tips Tip shut off is a feature of Model 4435 Robco QCG 4420 425 This multi purpose gun can be used to broadcast termiticide for injecting termiticide into perimeter soil and into the voids and soil beneath concrete slabs It can be fitted with 5 8 and 7 16 inch pipes and 1 or 2 gpm tips Tip shut off is a feature of Model 4425 Tips 451 453 457 These 2 gallon per minute tips are intended for use in applying liquid termiticides beneath concrete slabs using 7 16 inch pipes At 25 psi the tip 4451 dispenses liquid in a 360 pattern tip 4453 dispenses liquid in a 180 fan ar
19. screw on the Nosepiece Versagun cleaning This gun can be cleaned by removing the adapter tip which contains the Teflon gasket in the center Inspect and clean the gasket replace if itis damaged or worn Use a soft cloth or brush to clean the Shutoff stem Depress the trigger and screw the adapter tip in the body of the valve TROUBLE SHOOTING PROBLEM SOULTION Versatool is leaking around the Rod spring at the center of the valve handle Replace O rings on the Valve rod Disassemble the Trigger then remove the Seat gasket holder push the Valve rod out from above Versatool is leaking from the tip Remove the soil pipe and in the base of the Valve tighten Seat gasket holder with a 5 32 hex wrench If leak continues remove the Seat gasket holder and replace the white Seat gasket If tool continues to leak replace O rings on the Valve rod Disassemble the Trigger then remove Seat gasket holder push Valve rod out from above VersaGun leaking at the back of the valve Loosen the Lock nut 1 4 turn at the back of the gun this will re set the Shutoff stem to the gasket in the tip If leak continues the Packing screw may have to be removed and the packing replaced VersaGun is leaking at the junction with the soil rod Remove the tip and clean the exposed end of the Shutoff stem and the white gasket in the center of the tip If leak continues replace the tip the gasket can not be replaced separate

Download Pdf Manuals

image

Related Search

Related Contents

INSTALLATION MANUAL INSTALLATION MANUAL  Manuel d`Utilisation  istruzioni d'uso instruction manual mode d'emploi  VOSSLOH-SCHWABE Gesamtkatalog LED  Oxygen Therapy  取扱説明書をご熟読のうえ、正しく安全にお使いください。  IEEE 802.11N WIRELESS OUTDOOR CPE Quick  BarGraph Manual de instalación y uso  USER MANUAL USK1024 ACCES CONTROL DEVICE  