1. 2014 04V1 0 VIVOS VID VO JODA General Description Table of Content gt gt The system is a multi functional smart voice GSM alarm system adopted LFeatures SS 2 2 System construction and usage 3 Know the panel advanced GSM digital signal process technology integrated with digital voice support SMS self learning wireless coding remote appliance control and SMS recognition technologies Auto voice prompt and SMS alert available when alarm triggered Color digital screen can show you EM Nese e 6 the exact alarm direction clearly System is stable reliable secure and Door Sensor Installation and Test 7 user friendly Infrared detector installation and test 8 3 System Use and Set 9 Command sheet 1 12 It has been widely used in homes factories schools shops convenience i Host panel query function 17 stores financial and banking workplace community centre and a SMS enquiry and SMS control host functions 21 residential area to provide protection to valuable assets 4 Alarm reception amp Remote Control 23 5 Defense zone type and the panel parameter 24 6 FQA mSystem feature Adopt quad band GSM GPRS industrial graded module stable and reliable with voice prompt Directly check the phone bills and make phone call on panel Allow up to 120 wireless and 2 wired defense zones Each zone can be defined as one of the 8 zone types incl
2. 7 WELCOME 8 HELP SENIOR 0 1 0 represents siren no sound when the zone alarm Rect ARE ERINEN A A 2 Wired defense zone Settwo wired defense zone attribute 051 052 are wired defense zones System default 51 52 zone short circuit alarm NO mode Syntax 61 zone number 0 1 0 means NO and 1 means NC 051 052 0 1 NO means short circuit to alarm NC means open circuit to alarm To delete the scheduled arm and disarm time from To delete the 1st to 2nd groups scheduled clock time Set four groups timely arm disarm zones Set defense zone type attribute setting Remote setting functionExcept remote control detectors coding and record on off function all the other funtions can be set remotely Syntax 62 0 1 System default 1 on Assign specific phone 10 set specific phone numbers to certain zones number to certain zone System default 000 120 defense zones will dial from the Syntax 63 000 120 first to sixth group phone number begin zone 000 120 Remarks if user want a appointed phone number to dial end zone Phone alarmthe zone he can put phone number of the begin zone number 123456 the same with the end zone Clock display save mode on or off 0 means off 1 means on System default 1 When alarm host in standby state Syntax 84 0 1 If ON clock display auto off 1 minute later If OFF clock display will stay on Set audible voice on off Remote control or system operation v
3. to exit delete remote control mode 4 Add wireless detector In setting mode press 09 000 120 enter detector adding mode Q Note Specific operation please refer to Example 1 the host can add up to 150 detector 5 Delete wireless detectors In setting mode press 10 000 120 to delete corresponding detector Press 10 to delete all detectors Q Note Specific operation please refer to Example 2 For other function settings please refer to Command Sheet below Following command valid for a keyboard settings b remote phone call settings c SMS remote settings these three ways Example 3 If user want to set the first alarm number 13899998888 Three setting methods Method 1 Press to enter setting then press 3113899998888 and to exit Method 2 Make remote phone call voice prompt Enter Password u Enter 1234 host voice prompt correct password then press with a voice prompt set indicate remote setting entered Press 3113899998888 with corresponding voice prompts then press to exit Method three Texting 12343113899998888 to host number Host will reply with NO 1 Phone number 13899998888 set is successful Example 4 If user want to delete the NO 1 alarm number Method 1 Input 31 in remote phone setting status and then press to exit Method 2 Press 31 to enter into remote phone call setting status Method 2 Texting 123431 to host number Hos
4. Command 52 00 99 S system default 00 seconds Set Siren alarm time s Set siren alarm time 0 20 mins can be set Command 53 00 20 Minutes system default 1 min Set alarm panel and remote control operate zones area Set alarm panel and Factory default all remote control and panel can control remote control operate all 000 120 zones zones Remark The 1 remote control represented by number 001 represents the alarm panel keyboard Example 5 Ifyou want main panel to control 00 50 defense zone control number 000 120 Method one Starting defense zone Enter the configuration mode press 54 000050 and 000 120 End of press to exit configuration mode ethod two defense zone 000 120 Enter the remote configuration mode then press 54 000050 ethod three Send SMS message 123454 0050 Arm Disarm siren Use remote control and panel to Arm Disarm siren on off sound on off 1 means on and 0 means closed the default is on Command 54 remote E st kkk ano Example 001 represent 1 remote control represent controlnumber 000 120 main panel keyboard 0 1 Specific instruction refer to Example 5 Set system time and date Command 56 four digital year 01 12 Set the system date include year month day time Month 01 31 day minute and seconds 00 23 clock 00 59 miniute 00 59 second CU _ 2 2 2 2222 2 22222 2 222222 2 22
5. alarm ring time 00 20 minutes Press Enquiry key and then press 53 LCD display 01 means ring time is 1 minute Query of specific remote control and keyboard assignments to which zone 000 120 Press Enquiry key and then press 54001 LCD display 000 120 means 1 remote controller controling zone 000 120 press to clear screen Press 5402 to query 2 remote MFunction of call up The panel can be used as a phone to make phone call Syntax Enter 0 O phone number directly make phone call Press DISARM key to hang up e g If you want to call 13712345678 input 1 0013712345678 when panel in standby status and then can be get through At the end of your call press DISARM key press and then press to exit MPower cut off come back alert When AC power is off on host will dial the 6 number and send SMS message AC power off on to this number will h ith A A sn rue And AC power is on the panel will do the same with AC power ison NG 000 120 remote contrato ls Buds veice 7 a A prompt on off Remark If you disable the SMS message function or didn t set the ON means sound OFF means no sound present keyboard SMS alarm number this function will auto off e g Press Enquiry key and then press 5501 LCD display ON means 1 remote control with voice prompt while arm disarm Query system date and time Query the system date and time After DI sound Press Enquiry key
6. and then press 56 LCD display 2012 after DI sound display 0601 then DI sound Syntax 56 again display 1830 DIsound display 5 So the current time is 18 30pm 1 June 2012 Friday Query Ist to 4th group scheduled time and week for arm disarm two group clock bell time and week e g Press Enquiry key and then press 5701 to query the first group scheduled arm and disarm LCD display 22 00 after DI sound display 07 00 DI sound again display 12345 Syntax 57 01 06 means schedule time is from Monday to Friday 22 00 pm Arm 07 00 Disarm Query the zone number Query the 1 to 4 group scheduled arm disarm s zone number with scheduled arm disarm Press Enquiry key and then press 5801 to check the 1 arm disarm group controlled which zones display 000 120 means Syntax 58 01 04 it controls 000 120 zones Query the zone types of 000 120 and siren sound e g Press Enquiry key and then 600001 to check the Query type of wireless condition of 1 zone 1 on panel means NORMAL defense zone 2 means STAY ARM 3 means INTELLIGENT 4 means EMERGENCY 5 means CLOSED 6 means CHIME Syntax 60 000 1201 means WELCOME 8 means HELP SENIOR The word ON mean siren with sound OFF no sound Query the type of For query the zone type of 51 52 wired zones Example Press Enquriy key and then press 61051 to query re Syl zone alarm type show NO means short circuit to alarm while show NC means open circ
7. enter password enter your password 1234 factory default input wrong remind you input again wrong for three times hang up automatically Input right voice prompt correct password press cell phone telephone digital number can control following functions 1 key arm 2 key disarm 3 key listen in 4 key stop listening 5 key talk 6 key stop talking 8 key siren off 0 key turn off relay 7 key siren on 9 key turn on relay key hang up and exit key Enter remote configuration mode make general settings refer to Sheet 1 Commands Without any operation after 20 seconds auto hang up and exit Note 1 Listen in time is 20 seconds press key 3 in 20 seconds to Q keep listening 2 When monitoring press key 5 for two way intercom 3 When talk press key 5 in 20 seconds to keep talking Defense zone type and parameters There are 120 defense zones Every zone with eight different types 1 NORMAL Defense Zone Panel only works on ARM status No response while Disarm 2 STAY Defense zone HOME Defense zone While stay Arm detectors in stay zone won t alarm even triggered 3 INTELLIGENT Defense zone If the detectors in the zone triggered only once won t alarm But if triggered again within 30 seconds it will alarm immediately 4 EMERGENCY Defense zone No matter arm disarm it will alarm immediately once detector triggered Usually pair with smoke detector gas detector and emergency butt
8. protection function enabled please enter password to operate The initial code is 1234 1 Alarm message recording In alarm status dial preset phone number and play preset recorded message In setting status Press 19 and voice prompt to remind you start to record Record contents should be concise such as this is XXX home residential I llegal invasion here please help 10 seconds later the system will exit automatically Press any button to stop record 2 Add Remote Control In the setting status press 07 000 120 to add remote control 000 120 is zone number Example 1 Press 07 and then 001 to add the 1st remote control Take one sensor and let it transmit a signal to the host adding successful when voice prompt coding right If come out sound di once indicates repetition of code please change other sensors If you want to add more remote controls input other three digit code numbers Follow the same route Voice prompt in all operation Learning well press to exit learn mode press exit setting Q Note Panel maximum support 150 different code remote controls 3 Delete remote control In setting mode press 08 000 120 to delete corresponding remote control Press 08 to delete all remote controls E g 2 Press 08 then 001 to delete NO 1 remote control At this time directly input 008 if you want to delete NO 8 remote control input 010 to delete NO 10 remote control Press
9. remote operation setting and inquiries Syntax Description Send SMS message 12340 to host 0 Note 1234 is initial password use new password when it is changed 1 Send SMS messages 12341 to host for ARM 2 Send SMS message 12342 to host for STAY ARM 3 Send SMS message 12343 to host 4 Send SMS message 12344 to host Send SMS messages 12346 to host if host reply AC power ON or AC power OFF ON shows the power is normal and OFF shows outside power supply is abnormal or power off Example Send SMS message 123411 to the alarm panel the alarm panel replies with a list of related setting arming Relay out off Green Alarm out on 11 Send SMS on Remote set on Password 1234 Alarm delay 00s Arm delay 00s Siren on 1 min Siren VOL 99 Crack off Disturb off Key lock off Voice on 6 Return a list of Ist to 9th phone number group 30 for voice alarm 01 09 Example Send 12343001 to the alarm panel the alarm panel replies Group 1 phone number 13712345678 means the first voice alarm phone number is 13712345678 Nae Query 1st to 6th SMS numbers E g Send SMS messages 12346 to host panel 01 06 reply with 13888889999 which is the 1st SMS ee alarm number Query the assignment of remote control and keyboard o specific defense zone Example Send 123454001 to host host replies 001 remote control zone range 000 120 Keyboard zone range 000 120 it means 01 remote co
10. 0200 0 To set the time for scheduled arm and disarm from 1 to 4 group and choose week Example 6 set up the first group scheduled time to arm at22 00pm and disarm at07 00am this is valid fo r Monday to Friday Steps 57 Group number Method one Press enter configuration mode and then 01 04 AAAA time of arm press 57012200070012345 and then press to exit a N Method two enter the remote configuration mode and HEBER disarmitime i then press 57012200070012345 Number of week Method three Send SMS message 123457012200070012345 Timely Arm disarm time set Delete timely arm disarm time Command 57 Group 1 to 4 group number 01 04 0 Scheduled clock time setting TO set two groups clock ring time and choose week when ringing press any button to cancel or pess remote control Command 57 Group Disarm bUtON numer 05 08 Iir Suggestion you d better to put the remote control at AAAA start BBBB end N A a a 2 your bedside easier for you to operate Delete the clock time Syntax 57 Group number 05 06 0 Timely arm disarm defense zone settings Syntax 58 Group number 01 04 000 120 begin zone number 000 120 end SS Set 120 defense zone type 000 120 represents 0 120 zone number 1 8 represents one ofthe 8 zone type 1 NORMAL 2 STAY ARM 3 INTELLIGENT Command 60 4 EMERGENCY 5 CLOSED 000 120 zone numbe CHIME 1 8 type 0 1
11. 20 Example Send message 123480001 Front Door Open to the host it will send message zone 001 Front Door Open to 1 6 group numbers upon zone 01 being triggered Note Maximum length of message is 25 characters System will add zone number in the message automatically Query customized SMS message contents of zone 000 120 when alarm triggered Example Send 123481001 to the alarm panel to quer Note 1234 shown in above table all represents the initial password User can change password and use new password to operate Alarm reception amp remote control 1 What to do when get alarm call When alarm dial the preset telephone numbers from 1st to 6th group send SMS to 1st to 6th groups siren on off accord to your setting If one line is busy or can t get through auto dial next number every number call 3 times Get alarm call auto play 10 seconds recording without input password press cell phone telephone digital number can control following functions 1 key arm 2 key disarm 3 key listen in 4 key stop listening 5 key talk 6 key stop talking 7 key siren on 8 key siren off 9 key turn on relay 0 key turn off relay key hang up and exit won t dial the next number on list Remark If you don t press or 2 sytem continue to dial next number On 2 Remote control Use your phone to dial the host ring for a while system is connected automatically Voice prompt please
12. 20V 5A Wired door magnetic gap sensor E SIM card installation First step Open back cover case SIM card with gap side towards left Clock LED Light up Enable the clock function Second step Slide SIM card into the card seat from right to left en z En y ight up A disarm LED function gen KEYLOCK LED iaitu Enable Keyboard password Lt protection function SIM SIM E Recording LED Light up Enter recording status Dr feo i TTE Light up SIM Card loaded correctly SIM card indicator mSupplements ricer Unloaded SIM card or loaded wrong p RA All light u GSM signal stron short beep once Please enter GSM signal indicator g 9 g beep beep A Some light up GSM Signal weak still can alarm Built in speaker twice a beep beep beep Heeb ie Speaker indicator Light up Enable intercom function me y Error indication threeitimes gt Liaht off Save mode standby for 1 minute Voice prompt operation voice prompt Hea auto shut off LCD display Light up External power off using Light up Show current time or alarm state back up battery Four digital tube LED Battery Power LED Light off and time Show 98 alarm Press panel SOS alarm button External UPS normally supply clock right Show 97 alarm Tamper alarm Battery low Light up Backup battery is low voltage voltage LED BF Light up LCD display BF for 1 Second OUTARM ARM LED Fla
13. 6 in the remote control once Keyboard operation Press Key 6 in main panel once Emergency call When emergency comes press SOS Jand it will alarm regardless of working patter HM Door Sensor Installation and Test PIC 4 e Open the case install the battery properly by tear down insulation material Clean the installation place Put it on the door window that can close open Install the transmitter A on door frame and the magnet B on door Transmitter and magnet should at the same level distance between them should be within 10 mm Double sided tape or screws can be used fora firmly attachment Make sure panel can receive wireless signal sent by detector A large quantity of metal and antenna should be avoided in the area of detector Testing and Coding eThe newly bought door sensors should be coded to the control panel before use For specified operation please refer to the manual of alarm system Installation finished To confirm it works properly by open your door or window with a red indicator light flashing For more information please refer to corresponding Wireless Door Windows Gap Detector user manual Minfrared detector installation and test Fresnel Lens Walk Way PIC 5 eOpen detector case choose work mode When the power is on indicator light will be blue for 2 seconds and pair with panel blue light send out wireless alarm signal Red light battery low voltag
14. disabled the relay NO and COM can control home to exit appliance remotely Via remote setting to control on off If open password protection please enter the password to unlock ee u then press the Enquiry Q button to check the following instruction Remark Delete allphone numbers password back to 1234 but remote control and detector code won t lose Disconnect power turned off battery switch then press and hold ARM button on keypad respond with beep Query 1 6 group SMS phone numbers beep beep sound for 5 seconds release ARM button Press Enquiry key on keyboard and then press 41 Panel back to factory settings password 1234 delete all display screen will show 1 SMS number remote control and detector coding message Remarks If the user open password protection function but forget Please reset mandatory back to factory setting Query 1 9 group voice alarm phone numbers Press Enquiry key on keyboard and then press 31 display screen will show 1 group phone number Query current four digits password Press Enquiry key and then press 50 LCD display 1234 is current password Press to clear press then press Query delay arm time 00 99 Seconds Press Enquiry key and then press 51 LCD display 00 means delay time is 0 second Query delay alarm time 00 99 Seconds Press Enquiry key and then press 52 LCD display 00 means delay time is 0 second Query siren
15. e battery need a change Put case back Choose install position adjust install angle direction walk test the protection area make sure alarm triggered in three steps Install at 2 2 2 4 meters from ground using screws to fix bracket put the detector onit see PIC 5 Notice elndoor use only e Avoid sunshine direct strong light heat stoves air condition and moving objects Don t straight at door window or vents Detect direction must be tangential with body moving direction vertical 90 degrees is the best eWith pets at home please adjust the detector to higher view above 0 30cm from ground in case little pet trigger false alarm Take care of fresnel lens avoid dirty scratching falling down crashing In case damage inside components For more information please refer to corresponding PIR Montion Detector User Manual EJSystem Use and Set E First time use Open back cover put SIM card into SIM seat Insert adapter into power hole back up battery button switch to ON status After voice prompt Welcome to use voice gsm alarm system start to searching GSM signal SIM character in screen shows SIM card installed well signal bar on left place displays the signal strength If SIM and signal bars keep bright GSM signal and the SIM card are normal BJ General setting All the settings please insure input to confirm To exit press first then Q Note If keyboard password
16. ntrol is assigned o control zone 000 120 and keyboard is assigned to control zone 000 120 Query the system time by SMS Example Send 123456 to host host replies System clock 2012 07 01 12 00 Means the system is now July 1 2012 12 00am Query the four groups scheduled arm disarm about the time week and zones Example send 12345701 to the host the alarm panel replies 1 group scheduled timing arm and disarm settings Arm time 12 00 Disarm time 13 00 Arm Disarm week 1234567 Zone range 000 120 eans the first group scheduled time to arm at 12 00 and disarm at 13 00 this is valid each day scheduled arm disarm in 000 120 zone Query the type and siren setting of certain wireless defense zone Example Send message 123460001 to host host will reply zone 001 is wireless normal zone siren ON Check the host s zone 51 52 alarm type and siren status Example send text message 123461051 to host the host replies 051 zone is wired zone zone type normal siren ON alarm type NO t means zone 51 is anormal zone siren in it is on and alarm type is NO Z51 and GND in Short circuit alarm Query by SMS to know the phone number assigned to zone 000 120 Example send message 123463001 to host host replies zone 01 dial group number 123456 It means zone 1 will dial 123456 these six group numbers 9 Used to customize the SMS message to 1 6 group numbers for zone 000 1
17. number Forget to preset SMS number Set the SMS number Insufficient of SIM card or Pay phone bills validity passed Close SMS text function Enable SMS messages function Input correct password or nput Password wrongly change new password or Reset Mandator Re record according to Didn t record Fanuallbadk Coding unmatched with he host nsufficient power battery pieces poor contact or corroded Unmatched with host Re coding Change battery Polish elastic plate of battery Contact local dealer find a matching one Low power change battery Siren plug jack in short circuit or broken line Plug line cut off Siren closed Repair or change plug socket Change plug line Set siren ringing time A nearby emitter is find the interfering source transmiting and move it Baral eet Delivery back to manufacturer anel receiver failure for repairs Standby battery of the host insufficient SHEE TOSUBOWE Password keyboard Close password keyboard protection function ison protection function Voice prompt function is off Open voice prompt function a AR
18. oice prompt on off 1 ON 0 OFF Sa Bobb Meda System default 1 ON le disabl a Io Enable disable SMS on o System Default is 1 on Synta pl2 0 1 41 Remarks If you disable SMS function host won t send ER ENGE 0 ouk ony IIE SMS PSN ce here onee conse cess Siren volume adjustment 00 stand for minimum voice 99 for maximum voice system defalut Syntax 14 00 99 Please note Extremely low voice may leads to abnormal siren voice please should be used with caution Clock display save mode ON OFF Anti cracking In the ARM state Any remote control can t disarm the host but the host keypad can disarm Syntax 15 0 1 1 means ON 0 means OFF System default is 0 off Interference Alert on off A f In arm state when receive same wireless interference over Syntax 16 0 1 15 seconds host siren ring 5 seconds Panel display Tp Keyboard password When Keyboard password protection is on enter password protection before operation Factory default password is 1234 Syntax 17 0 1 System default is O means off Enable disable alarm linkage function MHost pa nel query function lis enabled and 0 is disabled system default is 1 Remark If enabled the relay NO and COM will turn to Press panel Enquiry Q key and then enter the following command close state Closing time same as siren ring time to check various parameters of the host settings press then press If
19. on etc 5 CLOSED Defense zone No matter arm disarm it won t alarm even detectors triggered 6 CHIME Zone No matter arm disarm detectors in the zone is triggered with door bell voice prompt 7 WELCOME Zone When Disarm detectors in the zone triggered with welcome voice prompt When Arm Stay arm status it will alarm once detector in the zone triggered 8 HELP SENIOR Defense Zone No matter arm disarm it will alarm with voice prompt help senior and dial 7 8 9 group numbers once detector in this zone is triggered Zone types system default a A A a a a aa ea ae ee E System default Operation password 1234 o no RRR ER EEEE AAEE ETET ELEELE S EE EREET Remote control operation Pr a OA T minute voice prompt Delay ARM Os Delay alarming Siren volume 99 0 120 zone alarm Alarm linkage Enable 51 52 wired zone alarm type SMS message Enable 1 120 zone SMS message Wi Panel parameters Input voltage DC9V 12V Standby currents lt 25 mA Alarm current lt 450 mA Wireless frequency 315 433 868 915MHZ 2262 1 5 4 7M EV1527 300K GSM Format Support GSM850 900 1800 1900MHz option Backup battery NI HI AAA 6 DC7 24V Alarm loudness 110dB B FQA Reasons Methods SIM card unloaded Load SIM card SIM need PIN code Cancel PIN code GSM signal weak Take to strong signal place or add GSM antenna Forget to preset alarm number Set voice alarm
20. shing every 1 second Delay arm Note Installation way of desktop and wall mounted for your choice Main panel should be placed in the middle of all wireless detectors to ensure best off Disarm reception but away from large metal objects or appliances with high frequency prj interference and reinforced concrete walls and fire doors and other barriers Stay arm LED LB Light up LCD display Stay arm LB for 1 second Light Al Alarm LED dal Zn Flash Delay arm 1 5 E How to use remote controller LED Indicator Stay Home ARM OUT ARM Put it ARM when Nobody at home Press the arm key all the detectors start to work Once detector motion infrared door magnet smoke and gas etc triggered panel will alarm immediately After armed arm LED will Light up and LCD show BF for 1 Second Remote operation Press Key inthe remote control once Keyboard operation Press Key O1 in main panel once STAY HOME ARM Press HOME ARM to enable some detectors working some not when at home In home alarm status fil LED will Light up and LCD show BF for 1 Second Remote operation Press Key Cap in the remote control once Keyboard operation Press Key ip in main panel once Disarm Press DISARM to stop alarm all the detectors won t trigger alarm except 24 hour emergency zone In disarm status 4 LED is off and LCD show CF for 1 Second Remote operation Press Key
21. t will reply with NO 1 Phone number delete successfully note Enter setting status input command in the following to set a en all the below command valid for the two methods Preset 1 9 group voice alarm phone numbers 1 9 indicates the 1st group to the 9th group alarm numbers Please refer to Example 3 for the specific instruction Remark 1 Power cut off or power on again it will dial the 6th Command 3 1 9 special number automatically and send SMS alert Phone number 2 Only when the SOS emergency alarm will dial 7th 8th 9th Group number Auto dial three times at most Delete voice alarm phone number Command 3 1 9 Set SMS alarm number Preset 1st 6th group SMS alarm phone numbers When er alen nesi will sane message to these six numbers Prene number Specific instruction refer to Example 3 Preset voice alarm phone number Delete 1 9 group voice alarm phone number Specific instruction refer to Example 4 Delete SMS alarm numbe Delete 1 9 group SMS alarm numbers refer to example Command 4 1 6 for specific instruction Password modification Sen To modify the user password the default user password 4 digits newpassword is 1234 Change it before using Delay arm time y Set the delay time for out arm 0 99 seconds can be set Command 51 00 99 S Set delay alarm time system default 00 seconds panel ready to alarm time 0 99 seconds can be set
22. tax 9901 ON means is needs alarm linkage while OFF means don t The system can save up to the most recent 72 disarmed records Press enquiry key and then press 9901 press 8 to scroll up and 0 to scroll down for records The first display is the record serial number like 01 It shows the 1 record Other indications as After DI sound 0801 means 1st August DI sound again 1210 means time is 12 10 DI sound once again shows the following features YC arm disarm from remote JP arm disarm from keyboard DS Scheduled arm disarm YK arm disarm from remote control CF disarm BF arm LSBF stay arm 01 remote control number 1 120 remote control number 120 Remark if first display DS and then show 01 02 03 04 it means 4 groups of scheduled arm disarm Press Enquiry key and then press 9900 press 8 to scroll up and press 0 to scroll down for records The first display is the record serial number like 01 It shows the 1 record After DI sound display date E g 0801 is 1 August DI sound again display time E g 1210 is 12 10 am DI sound once again display 01 mean zone 1 alarm 120 mean zone 120 alarm For query the arm district Press Enquiry key LED light flashing and then press 00 LCD show 000 120 means zone 000 120 in ARM state System can save up to the most recent 102 alarm records m SMS enquiry and SMS control host functions The following instructions is only work for SMS
23. uding NORMAL STAY INTELLIGENT EMERGENCY CLOSED CHIME HELP SENIOR WELCOME and HELP SENIOR E Four groups timely arm disarm choose different week and defense zone MWith clock display two groups ring bell function adjustable ring time E16 groups voice alarm phone number 3 groups help number 6 groups SMS number can allocate different zones with different preset number groups MEmbedded in a variety of intelligent voice prompts indicate alarm location and defense zone accurately when alarm System settings via keypad or make remote control phone call send SMS Remote control realize arm disarm listen in talk function M1 group relay linkage output to realize home appliances remote control MWireless learn code Maximum support 150 remote controllers and 150 sensors can be controlled in separate zones Check 72 arm disarm and 102 recent alarm events record Indicate alarm time and defense zone MBuilt in Ni Hi rechargeable battery and automatically switch to back up battery while power failure and with SMS alert WMSystem construction and usage mKnow the panel anti tamper switch 97 zones system default m built in standby battery SIM card seat pls mind the slip direction DC power socket Panel backside PIC 2 E Wired interface connection diagram SIREN SIREN NO COM 12V Z52 GND Z51 oo AC 2
24. uit to alarm Query remote operation on off Syntax 62 Query phone number To query the phone number assigned to zone 000 120 for alert e g Press query key and then press 63001 to see which number is allocated for 1 zone if display 123456 means these 6 group of phone numbers are assigned to 01 zone If display 34 3 and 4 group number is allocated to 1 zone Query timely arm disarm time and week To query if the remote operation is allowed it should show either ON or OFF for specific zone Syntax 63 000 120 Query clock display save mode on off Query audible voice prompt on off Syntax 11 Query SMS messaging function on off Syntax 12 Query same frequency interference alert Syntax 16 Query keyboard password protection To query clock digital tube display save mode on off ON open OFF close Query whether the system audible voice prompt on off ON open OFF close For query the SMS messaging function ON open OFF close Query for the volume level of siren 00 99 e g Press enquiry key and then press 14 to see the To query anti cracking function on off ON is open OFF is close To query interference alert is on off ON is open OFF is close To query if the password protection function is on ON is open OFF is close Query alarm linkage on off To query alarm linkage function Query alarm panel arm disarm records Syn