Home
Oxford Voyager Track Installation
Contents
1. WALL BRACKET WITH PIVOT PRODUCT A4950 BRACKET SHIM PRODUCT A0563 SUNRISE MEDICAL gt RAIL STOPPERS INSTALLATION DRILL RAIL HOLES AS ey INDICATED ry 5320 AX END STOPPER A5300 INSERT THE STOPPERS IN THE RAIL AND INSURE BOLTS ARE SNUG PLEASE NOTE DO NOT OVER TIGHTEN BOLTS SUNRISE MEDICAL gt TRACK LIFT CLEARANCE VOYAGER PORTABLE oO oo rd 5 c ux d Mi og DR VOYAGER 550 ES Tired bs x 25 no o E ec ER Cow O NN O N VOYAGER 420 48 nm 97 22 2463 4 65 1147 VOYAGER 800 SUNRISE MEDICAL gt DOOR FRAME DIMENSIONS FINISHED DIMENSION 550 fr CEILING TRACK LIFT DOOR FRAME CLOSE END WITH METAL WOOD OR DRYWALL BOTH ENDS CEILING Bus TRACK LIF DOOR FRAME CEILING EXPERIENCE TRACK LIFT DOOR FRAME TOLD US THAT THIS SOLUTION IS NOT RECOMMENDED SUNRISE MEDICAL gt LONG SPAN 6 METERS 236
2. PRODUCT 201 00550 i SAFE WORKING LOAD 250Kg 550158 sr 4 WEIGHT BY METER 6 22Kg m 4 1lbs p ga 17 6m 37Kg 81155 ae COMPATIBLE WITH ALL VOYAGER SERIES 1 X Y INSTALLATION WALL TO WALL INSTALLATION CEILING INSTALLATION 4 2 NEED A MINIMUM OF 2 RAIL ATTACHEMENTS BOTH ENDS SUNRISE MEDICAL gt WALL BRACKET INSTALLATION 7 WALL BRACKET SWIVEL WALL BRACKET PRODUCT A4900 PRODUCT A4950 M TYPICAL INSTALLATION WALL BRACKET WITH WOOD STRUCTURE m HE NB Must be fix 2 studs 2 4 WALL BRACKET WITH 8 1t CONCRETE STRUCTURE 1 1 L i 7 ux NIA 3 8 X X f d X 4 e 16 CC SUNRISE MEDICAL gt WALL BRACKET INSTALLATION WITH CHARGER CHARGER STOPPER TRACK SUNRISE MEDICAL gt SEMI PERMANENT RACK Product A9200 EN Te 18 Te 1 2 OR METER TRACK gt AN 219 86 2 12 Le HOW ORDER A SEMI PERMANENT RACK E PART DESCRIPTION QTY M0580 2 meter rail 1 or or M0585 3 meter rail 1 Rail Stopper 2 BORD only for Portable Voyager 3 meter power cord E7520 only for Voyager 420 or 550 1 North American plug MEDICAL gt TRAVERSE SYSTEM X Y CONT D Product A5800
3. _ CHARGER LOCATION y PART DESCRIPTION QTY A0110 Track bracket 4 ALB3 4FB Voyager 420 1 or or ALB2 4FB Voyager 550 PLEASE NOTE HARDWARE IS EXTRA SUNRISE MEDICAL gt INSTALLATION EXAMPLES CONT D N X x E X 4 N 5 DESCRIPTION QTY A0110 Track bracket 6 Voyager Portable Voyager 1 A5900 Standard trolley 2 A5320 End stopper 4 A8300 Arm extension optional 1 E0090 Handset optional 1 A3710 Strap extension optional 1 PLEASE NOTE HARDWARE IS EXTRA SUNRISE MEDICAL gt INSTALLATION EXAMPLES CONT D CHARGER LOCATION pi SP x x E PART DESCRIPTION QTY A0110 Track bracket 5 ALB3 4FB Voyager 420 or or 1 ALB2 4FB Voyager 550 PLEASE NOTE HARDWARE IS EXTRA SUNRISE MEDICA gt INSTALLATION EXAMPLES CONT D CHARGER LOCATION lt 1 PE x b PART DESCRIPTION QTY A0110 Track bracket 12 A5800 Traverse system X Y 1 FOR VOYAGER 420 OR 550 Voyager 420 1 Voyager 550 5320 End stopper 2 FOR PORTABLE VOYAGER Portable Voyager 1 A5900 Standard trolley 1 A5320 End stopper 6 A8300 Arm extension optional 1 E0090 Handset optional 1 A3710 Strap extension optional 1 PLEASE NOTE HARDWARE IS EXTRA SUNRISE MEDICAL gt RECOMMENDED TRANSFERT LOCATION 16 TO 18 400mm TO 450mm 0 DISTANCE BETWEEN 4 6 TUB AND
4. 16 x 36 5 Threaded rod M10 1m long Threaded rod 3 8 16 x 10 el Threaded rod M10 3m long 6 A0553 Lateral Bracket 10 7 Metal geling plate Metal geling plate 0 0 plate 100 20250 m 16 x 1 hex 9 Q0427 Hilti anchor HDI P 3 8 100 Hilti anchor HDI P M10 LENGTH DEPENDS ON DISTANCE BETWEEN CEILING AND TOP OF STRUC SUNRISE TURE MEDICAL gt SUSPENDED CEILING ATTACHMENT STEEL STRUCTURE WWW y SUSPENDED CEILING DRY WALL OR ACOUSTIC TILE STEEL STRUCTURE gt H Vid p A RAIL JOINT SHOULD BE IN CENTER SHOX OF ATTACHMENT 3 gt ETE LATERAL SUPPORT MAY BE REQUIRED IN SOME Nai ah INSTANCES DEPENDING ON THE DROP 5 Pa N CEILING MEASUREMENTS DESCRIPTION MIN 2 Standard metric QTY BRACKET ORDER STANDARD ATTACHMENT LATERAL 1 A0110 Track Bracket EEEN Q0405 Nut 3 8 16 3 000 00402 Locknut stover 3 8 16 100 Locknut stover M10 Q0350 3 8 16 x 1 hex 2 M10 25mm hex 100 Q0393 Threaded rod 3 8 16 36 5 Threaded rod M10 1m long 15 20894 Threaded rod 3 8 16 x 10 15 Threaded rod M10 x 3m
5. WOOD JOIST 27 22 4 i I RAIL JOINT SHOULD BE IN n CENTER OF ATTACHMENT WARNING WHEN USING LAG BOLT ALWAYS PRE DRILL HOLE DESCRIPTION MIN PART Standard metric SIMMERING SV ORDER STANDARD ATTACHMENT LATERAL A0110 Track bracket ER HARDWARE muras 16 x 1 hex 100 M10 x 25mm hex Q0740 Lag bolt 23 8 x 4 100 Lag bolt 10mm x 100mm long Q0426 Hilti unistrut nut 3 8 16 100 Hilti unistrut nut M10 Q1230 Hilti unistrut 1 5 8 x 10 10 Hilti unistrut 40mm x 3m REFER TO STEEL SPAN SPECIFICATIONS SHEET SUNRISE PLEASE NOTE METRIC PARTS ARE NOT AVAILABLE MEDICA gt SUSPENDED CEILING ATTACHMENT WOOD STRUCTURE UNISTRUT SPANNED WOOD JOIST 22 29 4 1 c3 BX YES SUSPENDED CEILING DRY WALL OR ACOUSTIC TILE 2 Lid WARNING WHEN 4 USING LAG BOLT i gu ALWAYS PRE DRILL SR 5 HOLE y LATERAL SUPPORT MAY JE Hz REQUIRED IN SOME INSTANCES E cm RAIL JOINT SHOULD BE IN DEPENDING ON THE DROP CENTER OF ATTACHMENT CEILING MEASUREMENTS DESCRI
6. 610mm 431 kg 950 Ibs 647 kg 1425 Ibs 36 in 914 mm 290 kg 640 Ibs 436 kg 960 Ibs RE ENFORCEMENT HILTI UNISTRUT The maximum allowable loads specified below should be at least two 2 times the safe working load of the lifting device Span fixed on supports at both ends Load BACK TO BACK SPAN Distance between supports Max allowable load at span centre Max allowable load at 1 3 of D Distance J between span jointing 48 in 1250 mm 72 in 1830 mm 590 kg 1300 Ibs 395 kg 870 Ibs 885 kg 1950 Ibs 592 kg 1305 155 16 in 406mm 24 inc 610 mm Joint span with two 2 3 8 in bolts Span fixed on supports at both ends Load SUNRISE MEDICAL
7. ATTACHMENT STD LATERAL 1 A0110 Track Bracket OTHER HARDWARE Q0405 Nut 3 8 3 000 00402 Locknut stover 3 8 6 100 Locknut stover M10 Q0393 Threaded rod 3 8 16 x 36 4 Threaded rod M10 1m long 15 Q0394 Threaded rod 3 8 16 x 10 15 Threaded rod M10 x 3m long 5 A0557 Metal ceiling plate 100 6 00740 Lag bolt 23 8 x 4 100 Lag bolt 210mm x 100mm long 7 Q0424 Suspended hilti unistrut nut 3 8 16 100 Suspended hilti unistrut nut M10 8 Q1230 Hilti unistrut 1 5 8 X 10 x 40 Hilti unistrut 40mm x 3m LENGTH DEPENDS ON DISTANCE BETWEEN CEILING AND TOP OF STRUCTURE SUNRISE z REFER TO STEEL SPAN SPECIFICATIONS SHEET MEDICAL gt SUSPENDED CEILING ATTACHMENT CONCRETE STRUCTURE 9 A CONCRETE STRUCTURE PRE CAST HOLLOW CORE lt SV SUSPENDED CEILING Im j DRYWALL OR ACOUSTIC TILE AA Wo RAIL JOINT SHOULD BE IN SE CENTER OF ATTACHMENT gt JC Usb 7 LATERAL SUPPORT BE REQUIRED SOME gt lt INSTANCES DEPENDING ON THE DROP CEILING MEASUREMENTS DESCRIPTION MIN PARU Standard metric QT ORDER STANDARD ATTACHMENT LATERAL n 3 8 stover 3 8 16 1 1 Hilti anchor HDI 3 8 16 100 Hilti anchor HDI M10 Q0393 Threaded rod 3 8
8. STANDARD TRACK BRACKET PRODUCT A0110 MOVING RAIL MAIN RAIL lt A TRAVERSE X Y 22 lt TROLLEY Ke 2 had pe PRODUCT A5800 G MAIN RAIL RAIL STOPPER PRODUCT A5320 TT 51 gt PART DESCRIPTION QTY PORTABLE VOYAGER A5800 Traverse system X Y 1 A5320 Rail Stopper 6 2 M0580 or M0585 Parallel rail any length 2 or 3 meter rails as many in a sequence as you like M0580 or M0585 2 meter traverse rail or 3 meter traverse rail A5900 Trolley 1 Voyager Portable Voyager track lift SUNRISE if you need more than 3 meters contact BHM MEDICAL gt CONTACT ASSEMBLY FOR TRAVERSE SYSTEM X Y For Voyager 420 550 Product A5810 MOVING RAIL RAIL STOPPER EN 5320 MAIN RAIL TRAVERSE X Y TROLLEY A5800 CABLE TO TRANSFER 27Vac FROM CHARGER STOPPER CHARGER AND RAIL TO MOVING RAIL STOPPER SUPPLY WITH MOTOR UNIT k L LONG STOPPER WITH CONTACT NO TRANSFO UNIT WILL CHARGE AT THIS END LONG STOPPER NO CONTACT CONTACT PCB RIVETED ON TROLLEY PRODUCT A5810 5 DESCRIPTION QTY VOYAGER 420 OR 550 OR 800 M0580 or M0585 Parallel rail any length 2 or 3 meter rails as many in a sequence as you like 2 M0580 or M0585 2 meter traverse rail or 3 meter traverse rail 1 if you need more than 3 meters contact BHM SUNRISE MEDICAL gt TRAVERSE SYST
9. TRANSFER POINT 100mm TO 150mm DISTANCE BETWEEN WALL AND THE RAIL 9 ol 225mm TRANSFER POINT THERAPEUTIC TUB 16 B 400mm DISTANCE BETWEEN 1 WALL AND THE RAIL 17 TO 20 NN 425mm TO 500mm s DISTANCE BETWEEN 5 ES TRANSFER POINT 100mm TO 150mm DISTANCE BETWEEN 1 WALL AND THE RAIL r 36 TO 40 900mm TO 1000mm DISTANCE BETWEEN HEAD BOARD AND ANS 2 POINT 10 250mm DISTANCE BETWEEN WALL AND THE RAIL WITH CHARGER 4 6 100mm TO 150mm DISTANCE BETWEEN WALL AND THE RAIL WITHOUT CHARGER ETR SUNRISE MEDICAL gt CURVE INSTALLATION PURPOSE The BHM A0590 joint kit is used to join straight rail and curve rail Our goal is to insure the best possible alignment 1 REQUIRED PARTS 2 union plates 2 590 2 hex bolts M6 x 80mm 03235 2 locknuts M6 03410 2 SUGGESTED TOOLS Plastic hammer Ratchet key 10mm box 10mm M flat blade screwdriver 000890 3 INSTRUCTION The union plates must be centered on both sides of the rail attachment At a slight angle insert the 2 union plates into the rail opening fig 1 Lift up slightly while pressing the plates together over the top of the rail Insert the 2 M6 X 80mm bolts into the union plate holes and attach wit
10. long 8 Q0424 Suspended hilti unistrut nut 3 8 16 1 1 100 Suspended hilti unistrut nut M10 9 Q0426 Hilti unistrut nut 3 8 16 1 100 Hilti unistrut nut M10 10 Q1230 Hilti unistrut 1 5 8 X 10 10 Hilti unistrut 40mm x 3m LENGTH DEPENDS ON DISTANCE BETWEEN CEILING AND TOP OF STRUCTURE z REFER TO STEEL SPAN SPECIFICATIONS SHEET SUNRISE MEDICAL gt CATHEDRAL CEILING WOOD JOIST WARNING WHEN USING LAG BOLT Nb Sel LI ALWAYS PRE DRILL HOLE DESCRIPTION MIN FART Standard metric EEE ORDER STANDARD ATTACHMENT STD LATERAL 1 A0110 Track Bracket OTHER HARDWARE Q0405 Nut 3 8 d 3 000 00402 Locknut stover 3 8 16 100 Locknut stover M10 Q0393 Threaded rod 3 8 16 x 36 4 Threaded rod M10 1m long 15 Q0394 Threaded rod 3 8 16 x 10 15 Threaded rod M10 x 3m long Coupling nut 3 8 16 Coupling nut M10 nm 6 Dowel screw 3 8 x 4 100 Dowel screw M10 100mm Lag bolt 3 8 x minimum 2 in the struc 7 i 1 100 Lag bolt 10mm minimum 50mm the structure LENGTH DEPENDS ON DISTANCE BETWEEN CEILING AND TOP OF STRUCTURE SUNRISE PLEASE NOTE METRIC PARTS ARE NOT AVAILABLE MEDICAL gt SPECIFICATIONS 41 2 1 5 8 41 3mm 1 5 8 22 28 7 8 SIMPLE SPAN H Distance Max Ma D allowable hb between load at span allowable load at 1 3 of D gt supports centre 24 in
11. 0175 SUNRISE PRODUCT A0180 MEDICAL gt TRACK SPECIFICATIONS m 67 5mm 2 11 1671 Material 6063 T5 aluminum lyx Maximum moment of inertia 1 08E 2 59 in Modulus of elasticity 6 894757 MPa 10E psi Extreme fiber distance from xx axis 48 61 mm 1 9141 in Id 7 Perimeter 554 mm 21 814 in lt Area 1311 6 mm 2 033 in l 19 1mm 3 4 Track load data when attached every 1 5 meter 59 e Maximum load before track failure 2 1384 kg 3050 Ibs _ CEILING Deflection at maximum load Fa e i 8 89 mm 0 35 in e Safe working load safety factor of 3 461 kg 1016 lbs 300cm 118in LOAD Track load data when attached every 1 meter 39 37 CEILING e Maximum load before track failure LLL LL fff 2100 kg 4625 lbs e Deflection at maximum load el 3 81 mm 0 15 in 300cm 118in e Safe working load safety factor of 3 T 700 kg 1542 Ibs SUNRISE MEDICAL gt TYPES OF BRACKETS USED STANDARD BRACKET PRODUCT A0110 REVERSE BRACKET PRODUCT A0562 RIGHT LEFT PRODUCT A0561 LEFT RIGHT STANDARD WALL BRACKET PRODUCT A4900 Ne METAL CEILING PLATE PRODUCT A0557
12. EM X Y PRODUCT A5800 MAXIMUM RANGE OF MOTION FOR TRAVERSE SYSTEM F D L 1 CENTIMETRES INCHES 300 MAX 118 AS LONG AS 9 oe DESIRED DESIRED 30 to 40 12 5V to 15 7 112 44 5 17 5 IF MORE IS NEEDED CALL BHM SUNRISE MEDICAL gt GATE FOR TRAVERSE SYSTEM Product 700 07500 Easy to install no modification to the rail needed Can be used on all BHM lifting products 700 07500 WHAT S INCLU Automatic system that works without any manual activation All mechanical system no electric power needed Safety feature that prevent the lift from falling in the rails aren t perfectly aligned with one another STANDARD X Y TROLLEY X Y TROLLEY WITH GATE SYSTEM ACTIVATION BRACKET SUNRISE MEDICAL MAXIMUM RANGE OF MOTION FOR TRAVERSE SYSTEM WITH GATE FIX RAIL 445 17 5 SIRED AS LONG AS DES END WITH GATE SYSTEM 210 8 2 kt ham 285 11 27 500 400 260 10 2 12 0 15 7 1 3000 118 2 MAX CALL BHM IF MORE IS NEEDE ES SUNRISE MEDICAL gt TURNTABLE The BHM Medical Turntable is a first class track junction system Adding flexibil ity to the design its main application is to provide access to two or more rooms while providing a continuous track path The turntable action is don
13. PTION MIN HAS Standard metric ORDER STANDARD ATTACHMENT STD LATERAL N 3 8 2 000 00402 Locknut stover 3 8 16 100 Locknut stover M10 4 20740 Lag bolt 23 8 x 4 100 Lag bolt 10mm x 100mm long Q0393 Threaded rod 3 8 16 x 36 5 Threaded rod M10 x 1m long 15 Q0394 Threaded rod 3 8 16 x 10 15 Threaded rod M10 3m long 8 90423 Suspended hilti strut nut 3 8 100 Suspended hilti strut nut M10 9 oes Hilti unistrut nut 3 8 16 100 Hilti anchor HDI M10 10 31230 Hilti unistrut 1 5 8 X 10 10 Hilti unistrut 40mm x 3 m Q0350 3 8 16 x 1 hex 11 M10 x 25mm hex 100 LENGTH DEPENDS ON DISTANCE BETWEEN CEILING AND TOP OF STRUCTURE REFER TO STEEL SPAN SPECIFICATIONS SHEET PLEASE NOTE METRIC PARTS ARE NOT AVAILABLE SUNRISE MEDICAL gt STANDARD CEILING ATTACHMENT WOOD STRUCTURE ACCESS TO STRUCTURE NS ANN WOOD 204 222 5 j 1 RAIL JOINT SHOULD BE IN CENTER OF ATTACHMENT WARNING WHEN USING LAG BOLT ALWAYS PRE DRILL HOLE PLEASE NOTE METRIC PARTS ARE NOT AVAILABLE 5 DESCRIPTION MIN FART Standard metric SMI AEE ORDER STANDARD
14. TING WITH THE VOYAGER YOUR LIFT is for transferring patients only Do not use the lift for any other purpose ALWAYS carry out the daily checklist before using the lift Voyager ceiling lifts are intended to be used for patients within the specified weight limit indi cated for the lift Do not attempt to lift more than the weight limit indicated Before attempting to transfer the patient must be assessed by a qualified professional Voyager ceiling lifts must be used by a caregiver with proper training to work with the patient to be transferred ONLY trained and qualified caregivers should transfer a patient DO NOT attempt to use the lift if you have not been properly trained to do so ALWAYS be prepared before attempting to transfer a patient FOLLOW N lifting procedures outlined in this manual Y 5 V gt SLING USAGE ONLY use Sunrise slings that are designed to fit with the Voyager ALWAYS refer to the Sling User Manual for instruction on fitting care and maintenance DO NOT use a sling that is not recommended for the lift NEVER use a damaged torn or frayed sling ALWAYS place the sling around the patient according to the instructions enclosed Voyager ceiling lifts are specifically designed for Sunrise Voyager ceiling rail systems slings and accessories Slings and accessories designed by any other manufacturer are prohibited and will void the Voyager warranty Use only Sunrise Medical slings and accessories
15. Track Installation for Voyager 420 550 amp 800 SUNRISE MEDICAL SAFETY INSTRUCTIONS AND WARNINGS IMPORTANT READ AND UNDERSTAND THESE INSTRUCTIONS DO NOT LOSE THEM ALSO READ OPERATING INSTRUCTION CHAPTER OF THIS MANUAL BEFORE INSTALLING OPERATING OR SERVICING THIS EQUIPMENT GENERAL gt IMPORTANT READ THESE INSTRUCTIONS CAREFULLY OR SERIOUS INJURY MAY RE SULT gt KEEP THESE INSTRUCTIONS AND THE KEY PROVIDED WITH THE LIFT AT ALL TIMES gt READ OPERATION AND MAINTENANCE INSTRUCTIONS IN THIS MANUAL BEFORE IN STALLING OPERATING OR SERVICING THIS EQUIPMENT gt An authorized contractor or installer must install Voyager ceiling lifts gt USE all controls and safety features only according to the rules specified in this manual Never attempt to force a control or button on the lift gt DO NOT store the charger in a shower bath or other areas with high humidity gt DO NOT drop the patient lift or battery Dropping the battery or lift may cause internal damage that is not easily seen If lift is suspected to be damaged take to an authorized technician for servicing gt IMPORTANT Keep all components of the lift clean and dry and have electrical and me chanical safety checkpoints done as instructed in the Maintenance section of this manual gt Replace any precautionary or instruction labels that cannot be easily read Avoid violent shock during transportation SUNRISE MEDICAL Y v wv gt LIF
16. e by an electric soft and low noise actuator mounted on the unit The turning action is commanded by pulling once on a simple cord Ro tation will start automatically come to a stop and lock at the end of its rotation ready to turn back to its original position on demand IMPORTANT FACTS TO REMEMBER ON THE TURNTABLE turntable is only available motorized An electrical outlet must be found close to the installation to accommodate the turntable return to charge function on our track lifts must be disconnected Re enforcement required to install the turntable SUNRISE MEDICAL 1 460 0mm 18 410 0mm 16 1671 _ 100 8mm 4 A 1 e x 1 8 E 4 0 o o 2 S 3 0mm 1 8 TURNTABLE 90 10 3mm 235 8 84 2mm 3 E PRODUCT A4000 90 460 0mm 18 410 0mm 16 100 8mm 4 AA NNN N N NIA NG NON c E G 3 1 o o gt 10 5mm 9 3 8 TURNTABLE 45 PRODUCT A4000 45 84 2mm 37 SUNRISE MEDICAL gt INSTALLATION EXAMPLES AND WHAT TO ORDER i
17. e their terminals with adhesive tape etc Otherwise the residual electricity in used batteries may cause fire or explosion PARTS AND ACCESSORIES Always use VOYAGER replacement parts and accessories Using other parts and accessories other than recommended by BHM SUNRISE could affect security and efficiency of the entire sys tem SUNRISE VOYAGER slings and patient lift accessories are specifically designed to be used in conjunction with BHM patient transfer aids Sling and accessories designed by other manufac tures are not to be used as a component of VOYAGER patient transfer systems EQUIPMENT WARNING LABELS INSPECT all precautionary labels on the equipment Order and replace all labels that cannot be easily read SUNRISE MEDICAL TRACK INFORMATION gt MATERIALS USED BHM Medical s track system as well as it s attachment accessories factured and installed following high safety standards BHM s tracks are made from high strength extruded aluminum and are bake paint coated to ensure a safe and aesthetically pleasing profile TYPES OF TRACKS AVAILABLE Note Tracks should be installed by accredited pro ue fessionals where pre ET scribed by law 2000mm 2M TRACK attachment per linear meter 39 inches of track in additional to an attachment at the end of the rail 6 4 3M TRACK 000mm PRODUCT M0585 90 TRACK PRODUCT A0170 SA 45 TRACK 30 TRACK PRODUCT A
18. h M6 locknuts fig 2 Tighten the bolts until joints are solidly aligned and secure fig 3 Verify that the trolley wheels turn freely and roll smoothly over the rail joint SUNRISE MEDICAL gt STANDARD CEILING ATTACHMENT CONCRETE STRUCTURE CONCRETE STRUCTURE 7 RAIL JOINT SHOULD BE IN TE CENTER OF ATTACHMENT N AC ai Wann PART Sui dE QTYIBRACKET ORDER STANDARD ATTACHMENT LATERAL 00 86 85 85 anchor HDI 3 8 16 100 Hilti anchor HDI M10 00350 3 8 16 x 1 hex 1 5 100 M10 x 25mm hex PLEASE NOTE METRIC PARTS ARE NOT AVAILABLE SUNRISE MEDICAL gt STANDARD CEILING ATTACHMENT WOOD STRUCTURE WOOD STRUCTURE d 2 21 Gls bd ZA GNE WY Ge Gay RAIL JOINT SHOULD BE IN CENTER OF ATTACHMENT IV WARNING WHEN USING LAG BOLT ALWAYS PRE DRILL HOLE DESCRIPTION MIN PART Standard metric STYBRACKENT ORDER STANDARD ATTACHMENT STD LATERAL 1 TrackBracket 1 2 00740 Lag bolt 03 8 x 4 100 Lag bolt 10mm x 100mm long PLEASE NOTE METRIC PARTS ARE NOT AVAILABLE SUNRISE MEDICAL gt STANDARD CEILING ATTACHMENT WOOD STRUCTURE NO ACCESS TO STRUCTURE
19. rical Codes gt Check nameplate for voltage and cycle requirements gt In special locations i e bathrooms showers or swimming pools a supplementary earth bond must be connected at the mains supply socket Where the Voyager Lift is supplied by a short length of flex from an adjacent power point the green yellow connection within the flex may be deemed to constitute supplementary bonding In some regions Local Authorities may specify an additional supplementary earth to the track This can be taken from any earth ter minal on the charger end stop Refer to a qualified electrician who knows the latest regulations in the installation of this equip ment ELECTRICAL WARNING SERVICE AND MAINTENANCE Disconnect power cord from the charger rail stopper or switch of transformer at power supply and unplug the battery from the lift before inspecting adjusting or servicing the equipment Dis connect power to equipment if it is to be left unattended or out of service FIRE AND EXPLOSION PREVENTION gt Batteries may explode leak and cause personal injury if not disposed of properly e Do not place or store the battery under direct sunlight or near a heat source e Do not dispose of in fire s Do not short the battery terminals e Do not incinerate e Flush with water if electrolyte Acid comes in contact with skin or eyes gt Batteries must be recycled disposed of according to local law regulations When returning batteries insulat
20. to maintain patient safety and product utility DO NOT use other manufacturer s slings DO NOT use Sunrise slings on other manufacturer s hoists ELECTRICAL WARNING SHOCK PREVENTION DO NOT touch or use a lift with bare conductors or a damaged power cord Electrically live equipment can electrocute a patient If the lift or charger has any exposed or damaged wires contact your local dealer immediately DO NOT cut or remove the round grounding prong from any plug All Voyager lifts are equipped with three prong plugs to protect from shock hazard or electrocution Any two prong electrical outlet must be replaced with a properly grounded three prong outlet accord ing to the National Electrical Code and local codes It is the responsibility of the customer to have the work done by a qualified electrician DO NOT splash or expose electric parts of the device to water or moisture CHECK nameplate for voltage and cycle requirements These requirements differ by country Do not attempt to use the lift in an area that has a different voltage and cycle requirement DO NOT attempt to expose service or repair the lift battery or charger If any unit is malfunc tioning contact your local dealer READ the battery and charger instructions thoroughly before using or storing them SUNRISE MEDICAL ELECTRICAL WARNING INSTALLATION AND GROUNDING gt Electrical equipment must be installed and maintained in accordance with National Elect
Download Pdf Manuals
Related Search
Related Contents
ClassPad 300 - Support Manual File System Migration User Guide User`s manual Iris405 User Manual Ver1 CE-6100 - Support Contenido Sony Ericsson Z520i Laser Tools Copyright Laser T ht Laser Tools Copyright Laser Tools BHR 51 PROFI LINE - 51S B&S - Migros.indd - Migros CPAP Sleep Apnea Therapeutic Device OLV Copyright © All rights reserved.
Failed to retrieve file