1. lt lt Contents gt gt lt lt Index gt gt General Specifications GS 01R01A01 01E FieldMate Versatile Device Management Wizard Fisigaie 1 Features FieldMate is available in a lt Basic gt and an lt Advance gt version with differentiated features provided FieldMate Basic is mainly used for the field device setting and adjustment which must be connected for all activity FieldMate Advance adds off line database function for up to 300 devices which maintains a complete record for all device configuration and maintenance activity FieldMate is a PC based configuration tool that per forms numerous tasks including initial setup daily maintenance troubleshooting and configuration back up for device replacement These tasks are stream lined by FieldMate s intuitive operation and integrated environment which is independent from communica tion protocols and device vendors FieldMate incorporates the open FDT DTM standard and is compliant with DTMs per the FDT 1 2 standard Additionally FieldMate supports both HART and FOUN DATION fieldbus H1 devices using the existing Device Description DD for devices that do not have DTMs available FDT Field Device Tool defines the system environ ment in which the DTM runs DTM Device Type Manager is the application which defines the Graphical User Interface GUI specific to the device The FDT frame is an integral part of FieldMate Many DTM s are incl
2. ace 1GB CD ROM Drive Windows XP compatible Display 1024 x 768 or better resolution recommend ed 16bit colors or better Network Port For BRAIN HART device One USB or RS 232C port e HART Modem Yokogawa option e FieldMate Modem BRAIN HART Yokogawa option All Rights Reserved Copyright 2006 Yokogawa Electric Corporation 24VDC Power Unit For FOUNDATION fieldbus H1 device A slot for PCMCIA card or a PCI slot e Fieldbus Interface Board National Instruments PCMCIA FBUS PCMCIA FBUS 2 PCI FBUS 2 NI FBUS Communication Manager 3 0 or higher F002E ai E Software Operating Environment OS Windows XP Professional SP2 English lt Advance Only gt For PROFIBUS device One USB port e PROFIBUS interface card and COMM DTM PROFlusb and PROF Idtm Softing e PROFIBUS DP PA coupler KFD2 BR A PA 93 Pepperl amp Fuchs 6ES7 157 OAC80 0XA SIEMENS GS 01R01A01 01E Jan 15 2008 00 lt lt Contents gt gt lt lt Index gt gt 3 5 Model and Suffix Codes Field device management software package FieldMate Release R1 03 MODEL SUFFIX CODES Model Suffix Codes Description Remarks FSA110 FieldMate Basic SS Teanga eo EE Single PC license eS oc ce ae re Oran a E E E E Language Option Code CD ROM FieldMate Software Media F9197DA CD ROM Device Files Media F9197DC USB HART Modem F9197UB USB FieldMate Modem BRAIN and HART proto
3. cols F9197UC MODEL SUFFIX CODES Woei Sufix Codes Description Remarks FisdMateAdvans OOOO Hcn N SEEE ee 0 Drone Japanes Sd Herren Engish Sd Language Option Code CD ROM FieldMate Software Media F9197DA CD ROM Device Files Media F9197DC USB HART Modem F9197UB USB FieldMate Modem BRAIN and HART protocols Techinical Specifications USB Interface SOFTWARE ae F9197UC Replacement disk only 6 External View External view of USB HART modem or USB FieldMate modem BRAIN HART Unit mm F003 ai Fig 3 USB HART Modem or USB FieldMate Modem Total cable length Approximately 2 3m All Rights Reserved Copyright 2006 Yokogawa Electric Corporation USB2 0 standard 1 ELECTRICAL 2 pin polarity insensitive Mini Pins to Device grabber test clips Detachable alligator clips addtionally 2 0 5 0 1 Vpp trapezoidal PU varie wave 1200 2200 fe Output Level BRAIN in pp trapezoidal Isolation DC 1910 VDC between instru ment and computer ENVIRONMENTAL S 0 to 95 relative humidity PHYSICALDIMENSIONS 83 x 46 x 18 mm ABS indus Enclosure trial enclosure 190 cm 2 conductor Device Interface Cable terminating with two mini grab ber clips USB Cable inating 27 cm cable terminating in a CERTIFICATION EN61326 USB type A connector q USB2 0 also covers USB1 0 2 FieldMate modem GS 01R01A01 01E Jan 15 2008 00 lt lt Contents gt gt lt lt Index gt
4. gt 7 Included Items FieldMate includes the following items lt Product gt CD ROM FieldMate Software Media CD ROM Device Files Media USB HART modem w cables optional USB FieldMate modem BRAIN HART w cables optional lt Documentation gt License number sheet Getting Started Operational Precaution 8 Items Contained in Media E Items contained in the CD ROM of FieldMate R1 03 1st CD ROM FieldMate Media FieldMate Program USB modem driver User s Manual for FieldMate 2nd CD ROM Device Files Media Device DTM for Yokogawa devices BRAIN FOUNDATION fieldbus H1 HART PROFIBUS Device DTM for the HART devices DD for the FOUNDATION fieldbus H1 devices DD for the HART devices 1 Devices registered with HART Communica tion Foundation some DTM or DD may not be included 2 Devices registered with Fieldbus FOUNDATION some DD may not be included Remarks Yokogawa certifies the quality and operability only of DD and DTM which have been registered by Yokogawa All Rights Reserved Copyright 2006 Yokogawa Electric Corporation Subject to change without notice 9 User Registration FieldMate may be installed on a single PC using the license number provided FieldMate may be used for up to 30 days without registration For permanent installation user registration is required After registration an Activation Key is provided to the user User registratio
5. n may be done on the FieldMate User Registration web site The items required for user registration are the license number and Hard Disk se rial number Volume Serial Number of the PC to which FieldMate is installed 10 Trademarks All brand or product names of Yokogawa Electric Cor poration in this document are trademarks or registered trademarks of Yokogawa Electric Corporation All other company brand or product names in this docu ment are trademarks or registered trademarks of their respective holders GS 01R01A01 01E Jan 15 2008 00
6. nfiguration files may be imported exported from to the device easily and stored on the PC for future needs DD Menu FOUNDATION fieldbus H1 The existing fieldbus DD is utilized to enable function block configuration E History Function Logs of operations are automatically recorded 1 Date amp Time 2 Device Tag Device ID User Source DTM works DD Menu Parameter Man ager etc 6 Category Configuration device parameter change and System logs of login etc 7 Message Details log of changes 3 4 5 SS SNS NSI E 3rd Party DTM Function This function provides device interface in compliance with FDT 1 2 enabling the features defined by the device vendor s DTM YOKOGAWA Yokogawa Electric Corporation 2 9 32 Nakacho Musashino shi Tokyo 180 8750 Japan Tel 81 422 52 4443 Fax 81 422 52 2018 GS 01R01A01 01E Copyright June 2006 2nd Edition Jan 15 2008 lt lt Contents gt gt lt lt Index gt gt 2 lt Advance only gt E Device Interface Function Device Navigator Shows all registered devices Provide a searching function by tag device name memo etc Online registration and offline registration can directly be implemented from Segment Viewer Device Navi gator Marking it with flags to remind users of outstanding issues etc simplifying daily maintenance E Database Function Device Maintenance Info Provides advanced maintenance information consist ing of Device I
7. nformation User memo Document link History 3 Connection Example for reference All information can be exported imported and can be saved as a Device Template Parameter Manager DTM works Parameters may be loaded from or saved to the of fline database m User management Provides simple security and activity logging by allowing users to be defined by a user name and password The user ID is incorporated as part of the device maintenance history E 3rd Party COMM DTM support Provides advanced connections and communication networking enabling Access PROFIBUS PA DP devices Access HART devices via PROFIBUS Access 3rd Party multiplexers User defined communication topology can be saved in FDT project PRM Plant Resource Manager Synchronization Synchronize information between FieldMate and PRM to make best use of PRM as a master data base Bi directional file transfer operation is supported Sample BRAIN or HART configuration connecting a pressure transmitter Required Components BRAIN or HART EJA Pressure Transmitter 24 V DC Power supply Load Resistor USB FieldMate Modem BRAIN HART USB FieldMate MODEM PC FieldMate 4 System Requirements m Hardware Operating Environment e PC Machine IBM PC AT compatible CPU Pentium III 1 GHz or faster Pentium 4 1G or faster recommended Main Memory 1 GB or more Hard Disk Drive 8 GB or more minimum free sp
8. uded with the FieldMate application and additional DTM s are available from most field device vendors 2 Functional Details The following columns identify the features available in both the Basic version and the Advanced version FieldMate Basic Advance F001 ai E Communication Function FieldMate supports the following communication protocols BRAIN FOUNDATION fieldbus H1 e HART PROFIBUS E Device Interface Function Segment Viewer BRAIN FOUNDATION fieldbus H1 HART PROFIBUS Displays a list of devices currently connected on the communication lines grouped by protocol Basic device specific information is displayed de pending on protocol Device ID Manufacturer ID address Device type Device revision and status Device Viewer FOUNDATION fieldbus H1 HART Displays the current status of the field device includ ing errors warnings good status The status display icon red yellow green clearly indicates the device s self diagnostic status E Configuration Function Device parameters can be easily configured DTM Works BRAIN FOUNDATION fieldbus H1 HART PROFIBUS The DTM Works provides not only configuration but easy setup calibration simulation wizards etc as defined by the device vendors DTM Parameter Manager FOUNDATION fieldbus H1 HART The Parameter Manager is a simple parameter view ing window in which adjustment and field device replacement can easily be performed Co