Contents

1. F 113 F 10 C 45 C Temperature Storage Temperature 40 F 158 F 40 C 70 C Operating Humidity 10 90 RH non condensing Storage Humidity 5 90 RH non condensing Dimension 9 3in x 4 0in x 1 0in 235mm x 103mm x 27mm 12 9 port Gigabit Ethernet Switch with 8 port PoE B Safety and Emission Statement C CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures NOTE 1 The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment 2 To avoid unnecessary radiation interference it is recommended to use a shielded RJ45 cable FE FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radiofrequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense F
2. 9 port Gigabit Ethernet Switch with 8 port PoE LinksKey LKS SG9P8 9 port Gigabit Ethernet Switch with 8 port PoE User Manual Rev 1 0 9 port Gigabit Ethernet Switch with 8 port PoE Contents Chapter 1 Introduction 00 0 0 eee cece es eeeee ress ceceeseeesesseseseeseeeseseesesenaeees 1 T ProductOVerView eniin e RERO iere ds 1 1 2 Packa ge Cohtents ete be tt tetto 1 1 3 Physical Description oce dett ene e ote iei ness 1 Front Pane eec 1 i i du n R E 3 Chapter 2 Installation 2 1 Safety Precautions 2 2 Site Requirements Operating Temperature and Humidity ssssss 5 e IDIcD M 6 Lightning Protection isis tec ti eie ea 6 Installatiori Site eae n one nen 6 2 3 Installation TOONS 5 1a rtr cie tere tee ER ERE 6 2 4 Product Installation Desktop Installation Magnet Installation Wall Mount Installation 2 rt teet tete s 8 2 5 Connect to Protective Grounding Cable ssssssss 9 With Grounding Bar 2 reticere teer Lites tins 9 Chapter 3 Hardware Connection esses seen tenente tnn 10 Appendix A Technical Specifications B Safety and Emission Statement 9 port Gigabit Ethernet Switch with 8 port PoE Chapter 1 Introduction 1 1 Product Overview The Linkskey LKS SG9P8 Gigabit Ethernet with 8 port PoE Switch provides you with an ideal seamless solutio
3. CC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE 1 The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment 2 To avoid unnecessary radiation interference it is recommended to use a shielded RJ45 cable 13
4. ces made by the extremely high voltage current produced when lightning occurs please take the following lightning protection measures Ensure the rack and the switch s ground terminal are well earthed Make sure the power outlet has a good contact with the ground Keep a reasonable cabling system to avoid induced lightning Use the signal SPD Surge Protective Device when wiring outdoor Installation Site When installing the device on a rack or a flat workbench please note the following items Make sure that the rack or workbench is sturdy enough to support the switch and well grounded Make sure that the switch has a good ventilation system The device should be left 10cm of equipment clearance for ventilation Do not place objects on the switch If the switches need to be used in stacked the vertical distance between neighboring ones cannot be less than 1 5 cm 2 3 Installation Tools Phillips Screwdriver ESD preventive Wrist Wrap Network Cables Option 9 port Gigabit Ethernet Switch with 8 port PoE 2 4 Product Installation Desktop Installation Step 1 Set the bottom of the switch up on a flat and stable desktop Step 2 Paste four cushions in the corresponding concave places at the bottom Step 3 Turn over the switch and place it face up on the workbench Figure 2 1 Desktop Installation Magnet Installation Step 1 Attract 4 magnets into the corresponding round grooves
5. ered on properly PoE Green Port 1 to 8 Powered Device is powered off or not Off connected properly Port 9 PoE feature is not supported Table 1 2 LED Status Back Panel The back panel mainly consists of a grounding terminal for lightning protection Kensington security slot and a power socket shown as Figure 1 2 re MEBUHLUHDNLLONDCLDELULODLLIT 99 Security Slot Grounding DC Input Jack Terminal ed oa Figure 1 2 Back Panel 1 Kensington Security Slot Use an anti theft lock to attach the switch to a fixed object against theft 2 Grounding Terminal Use a wire to connect the terminal to the ground for lightning protection For details please refer to section 2 5 Connect to Protective Grounding Cable 9 port Gigabit Ethernet Switch with 8 port PoE 3 Power Input Jack Plug the DC power output to this power input jack to supply power for the switch Power Input 100 240V AC 50 60Hz Power Output 51V DC 2 5A Note Please use only the power supply provided with the switch 9 port Gigabit Ethernet Switch with 8 port PoE Chapter 2 Installation 2 1 Safety Precautions To avoid any device damage and bodily injury caused by improper use please observe the following rules Keep the power off during the installation Wear an ESD preventive wrist strap and make sure that the wrist strap has a good skin contact Use only the power supply provided wi
6. n of high performance low cost easy to use and boosts your 10 100Mbps local area network to 1000Mbps The switch supports 10 100 1000M auto sensing and protects the existing network investment when you enjoy the gigabit network The switch is plug and play with no configuration required Diagnostic LEDs which display link status and activity allow you to quickly detect and correct problems on the network The LKS SG9P8 also provides eight PoE capable ports of the switch up to 30W output power on each port which can solve the problems resulting from wiring complexities high cost and maintenance difficulties of network devices 1 2 Package Contents Open the package and verify the following items carefully If any of the listed items is damaged or missing please contact your local reseller 1xLKS SG9P8 Gigabit Ethernet Switch with 8 port PoE 1xPower Adapter e 1x User Manual e 1x Magnet Kit 4 magnets and 4 screws e 4x Rubber Foot Pad e 2xScrew Set e 1xProduct Warranty Card 1 3 Physical Description Front Panel The front panel mainly consists of RJ45 ports and LEDs shown as Figure 1 1 9 port Gigabit Ethernet Switch with 8 port PoE 1 RJ45 Ports S E 2 cv Mull A A mexmuukkmms Bh 3 3 3 3 FT Power PoEMax 3 x 10 100 1000Mbps RJA Ports EAS Figure 1 1 Front Panel There are nine 10 100 1000M RJ45 ports of which port 9 is the Normal Uplink port others are downlink p
7. on the bottom at each corner of the switch s housing Step 2 Use screws to secure the magnets to the switch s housing shown as Figure 2 2 a Step 3 Press the switch installed with magnets in a proper way on a stable surface you select shown as Figure 2 2 b Figure 2 2 Magnet Installation wo 9 port Gigabit Ethernet Switch with 8 port PoE te Select the installation surface carefully If the surface is not proper the reliability of this installation will be compromised Too high installation position or vibration might cause a fall leading to Switch damage or personal injury When installation is finished don t move the switch very often to avoid surface coating damage To make it cable more easily please place the switch bottom up when you mount it vertically and pay attention to the weight of the installed cables to avoid a fall Keep magnets away from objects such as the floppy disk magnetic card computer or computer monitor which are easy to be magnetized Wall Mount Installation Step 1 2 holes Drill 2 holes with a diameter of 5mm on the wall The distance between the is 110mm and the line through them should keep horizontal as illustrated in Figure 2 3 Step 2 Install a drywall anchor inside the board hole and flush the edge of the drywall anchor with the wall surface Step 3 Fasten the screws into the drywall anchor Distance between the inside surface of the screw header and
8. orts From port 1 to 8 of the downlink ports are PoE capable details shown as Table 1 1 PoE capable Ports 1 8 Compliant with the IEEE 802 3af and IEEE 802 3at standards Up to eight IEEE 802 3af compliant 15 4W per port or four IEEE 802 3at compliant 30W per port powered devices PDs can be accessed simultaneously connected on any PoE capable port Table 1 1 PoE capable Ports EP Tips PoE implements two ways of supplying DC power over the RJ45 Ethernet cable In Mode A is also known as Phantom Power the wire pairs which are used for data transmission are also used to provide the power Pair 1 and 2 Pair 3 and 6 You re recommended to use Cat 5 or higher UTP STP cables 2 LED You can check link status and activity of the switch via LEDs Table 1 2 describes the LED status 9 port Gigabit Ethernet Switch with 8 port PoE LED Color Status Description Solid The switch is powered on POWER Green Off The switch is powered off or its power supply is improper PoE consumption exceeds the power limit or no more PDs can be powered on Off PoE consumption is proper Proper network connection on the corresponding PoE MAX Green S0lid Solid RJ45 port Link Act Orange Blinking Traffic is being transmitted on the corresponding RJ45 port Off No network connection is on the corresponding RJ45 port Solid Powered Device is connected to the corresponding port and pow
9. r RJ45 Ethernet cable connect a downstream network device to downlink port PoE capable ports can access PDs such as an AP IP phone IP camera shown as Figure 3 2 10 9 port Gigabit Ethernet Switch with 8 port PoE Manassas amp 3 Figure 3 2 Installation with Powered Devices Step 3 Use the AC power adapter provided in the product package to supply power for the switch shown as Figure 3 3 Figure 3 3 Installation with the AC power adapter Step 4 After powered up the switch begins auto initialization Check the LED indicators and they will respond as follows All the functional LEDs will flash momentarily for one second and then go off which represents a resetting of the system The POWER LED indicator is lit 11 9 port Gigabit Ethernet Switch with 8 port PoE Appendix A Technical Specifications Item Specification Protocol amp Standard IEEE 802 3i 10Base T Ethernet IEEE 802 3u 100Base Tx Fast Ethernet IEEE 802 3ab 1000Base T Gigabit Ethernet IEEE 802 3x Flow Control IEEE 802 3af PoE IEEE 802 3at PoE Total power of the switch 127 5W maximum Total power of the PoE power supply 121 22W Power Supply maximum DC Power Output 51VDC 2 5A MAC Address Table 4K LEDs POWER PoE PoE MAX Link Act PoE Power Media Cat 5 s100m or Cat 5 higher UTP STP cables s150m recommended Operating 14
10. th the switch Make sure that the supply voltage matches the specifications identified on the power adapter provided with the switch Ensure the vent hole is well ventilated and unblocked Do not open or remove the housing of the switch Before cleaning the switch power off the power supply Do not clean it by the waterish cloth and never use any other liquid cleaning method Keep the switch away from nearest source of high voltage such as power lines electric lamps grids etc N Note If needed to open the device s housing please contact Linkskey to get permission or you have to be responsible for the result that the device cannot be maintained because of unpermitted operation 2 2 Site Requirements Operating Temperature and Humidity Requirements of temperature and humidity to the switch are shown as Table 2 1 Environment Temperature Humidity Operating 14 F 113 F 10 C 45 C 10 90 RH Non condensing Storage 40 F 158 F 40 C 70 C 5 90 RH Non condensing Table 2 1 Temperature and Humidity Requirement 9 port Gigabit Ethernet Switch with 8 port PoE Cleanness To avoid the effect of static electricity on the operation of the switch please refer to the followings Dust the switch regularly and keep the indoor air clean Keep the switch well grounded and ensure static electricity has been transferred Lightning Protection To avoid the damage of electronic devi
11. the edge of the drywall anchor should not be less than 2 5mm to make sure that the device can be hung on the bolt tightly Step 4 Align two wall type holes at the bottom of the device with the screw and hang the device on it 9 port Gigabit Ethernet Switch with 8 port PoE Egi 7777 IET EP Figure 2 3 Wall Mount Installation 2 5 Connect to Protective Grounding Cable Proper connection of the protective grounding cable is not only for quickly releasing the overvoltage and overcurrent resulting from lightning but also necessary precaution of preventing bodily injury With Grounding Bar Connect one end of the protective grounding cable to the binding post on the grounding bar and fix the screws shown as Figure 2 4 oe LUULDLLLLLLUDULLLLLLUDAAALULLLLA ew Figure 2 4 Installation with Grounding Bar 1 DC Power Input Jack 2 Binding Post 3 Protective Grounding Cable 4 Grounding Bar 9 port Gigabit Ethernet Switch with 8 port PoE A note The switch s grounding cable should be connected to the metal support rod Chapter 3 Hardware Connection Connection Procedures Step 1 Use a RJ45 Ethernet cable to connect an upstream network device such as another switch or a router to the Normal Uplink port which is port 9 on the Switch shown as Figure 3 1 temen _Internet Figure 3 1 Installation with upstream network device Step 2 Use anothe