1. As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS message it is necessary to remove users NO2 and NO3 and disable alarm calls for all users It is also necessary to invert Esim252 input from NO to NC mode so that alarm is given only when the signal disappears a First of all a signal indicating gas boiler breakdown isconnected to Esim252 input Z1 b The following configuration SMS message must be sent to Esim252 system XXXX SMSEXTRA Z1 SC23 CC123 LI1 where SC23 means that alarm SMS message sending is disabled for users NO2 NO3 input Z1 is violated CC123 means that alarm calls are disabled for users NO1 NO2 and NO3 after input Z1 is violated We make an assumption that users NO4 NO5 were not entered to the system at all LI1 means that NC normally closed mode is enabled for the input 22 A FOR ADVANCED USERS All these features can be configured using program ELDES Configuration Tool Task No2 Configuring the system so that the operating personnel member NO2 receives SMS message if the pump s input was violated for 10 times Worker Gas boiler NO1 Worker NO2 pela system NO3 As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS message it is neces
2. P a confirmation call Setting See below confirmation call cs for period start p Users are not notified 0 oh 3 CS0 means that nobody is informed about period 0 about period start by S Call is not start by a call a confirmation call made CE1 means that the preset user is informed about Users are notified E E 4 y the period end of output turning on or off via short 1 about period end by a B A call The user is set by using UC command confirmation call Setting See below confirmation call CE for period end u tho fied CEO EE p R S CEO means that nobody is informed about period 0 about period end by a gt A Call is not end by a call confirmation call made A The first digit is a command the last digit refers The user receives Beas a y to call time in seconds E g CT12 means that if a confirmation call S a Confirmation call cT ds WhentheGutoutis 2 confirmation call mode is enabled whether for duration 7 ie period start or end the call will be forwarded to the turned on a A Ln user when output is turned on The system will call s call time in seconds for 2 seconds 30 i FOR ADVANCED USERS A All these features can be configured using program ELDES Configuration Tool The first digit is a command the last digit refers to call time in seconds E g CTO8 means that if confirmation call mode is enabled whether for period start or end the call will be forwarded to the user w
3. g XXXX_INFO 01 10 means that status message will be sent every 1 day at 10 00 If PP value is O and VV in the range of 1 23 then periodic status messages will be sent multiple times per day with period being specified as VV time E g XXXX_INFO 0 2 means that status message will be sent every 2 hours To disable periodic status messages send the following SMS message XXXX_INFO 00 00 The status messages will not be sent until enabling or restoring default parameters or receiving previously described XXXX_ INFO PPVV SMS message 3 4 Blocking Unknown Numbers By default Esim252 system can be controlled from any of the preset users NR1 NR5 However the user can access the system and control parameters and outputs from any number as long as password is known To enable this feature send the following SMS message XXXX_STR ON To disable this feature send the following SMS message XXXX_STR OFF USER MANUAL ELDES ESIM252 V1 0 11 3 5 Remote Microphone Listening NOTE To enable this feature it is necessary to connect microphone connector to MIC slot The microphone is additional equipment tha can be purchased in trading centers You can listen to what is going on in the secured premises by sending the following SMS message XXXX_MIC The system will ring the sender of the received SMS and upon answering the call the user can listen to any sounds in the building The phone call must be answered within 20
4. impulses is defined by the command IC is enabled E 0 151 Impulse counting Eh The alarm is activated when a preset number of impulses is transmitted to the The number of impulses is input E g IC100 Is 124224067233 determined In this case the alarm is activated when 100 impulses are sent to the input Maximum frequency is 5Hz The input is violated only if the impulse Input protection Setting minimal input transmitted is not shorter than the preset against DV 100 10000 impulse duration It is DV600 value E g DV1000 means that the signal interference measured in milliseconds transmitted to the input is shorter than 1000ms 1s the alarm is activated USER MANUAL ELDES ESIM252 V1 0 25 i FOR ADVANCED USERS A All these features can be configured using program ELDES Configuration Tool ATTENTION Value fields are separated by commas Maximum SMS length is 160 characters Only one input parameter can be configured by one SMS message Examples of using SMSEXTRA command Suppose in all cases initial parameters were not changed and are manufacturer default 1 Example of SMS message configuring Z1 input XXXX_SMSEXTRA Z1 SC15 CC25 SE1234 CE4 LE1 DV900 This message configures Z1 input parameters SC15 means that during the alarm SMS message sending is disabled for users NO1 and NOS As per manufacturer default settings SMS sending is preset for all users therefore users NO2 NO3 a
5. CBO CBO means that when users control CallBack i cB 0 Confirmation call mode the output via SMS message they will is disabled for all users Disabled for all not receive a call informing about a users NO1 NO5 successful output status change The first digit is a command the last digit All users receive refers to call time in seconds E g CT12 dis confirmation call when 2 means that if confirmation call mode is y the output is turned on enabled the call will be forwarded to the s call time in seconds user who is trying to turn on the output a AET The system will call for 2 seconds dutin The first digit is a command the last digit All users receive refers to call time in seconds E g CTO8 S confirmation call when cTo8 means that if confirmation call mode is 2 the output is turned off enabled the call will be forwarded to the s call time in seconds user who is trying to turn off the output The system will call for 8 seconds SB1 SB1 means that when all users control Confirmation SMS the output via SMS message they will Enbinl i m a ee disabling a users NO1 NO5 ge ey message confirmation SMS message SMS confirm Confirmation SMS SBO means that when all users control aa the output via SMS message they will not SB 0 mode is disbled for all x gers be informed about a successful output status change by SMS message Example of SMS message configuring C2 output w ays of information XXXX_SMSEXTRA 0CS2 CB1 CT13
6. NO2 and NO4 cc 12345 pre area cana E g CC12345 means that during the alarm A none of the users will be called disabled During input restore SMS E g SE1 means that during input restore SE 1 2 3 4 5 message will be sent to SMS message delivery is enabled for user users No 1 2 3 4 5 NR1 During input restore SPIER E g SD45 means that during input restore Restore SD 1 2 3 4 5 SMS message sending is De etA SMS message sending is disabled for users A disabled for No 1 2 3 4 5 NO4 and NOS configuration users NO1 NO5 CE 12345 During input restore users E g CE12 means that during input restore an No 1 2 3 4 5 will be called calls are enabled for users NO1 and NO2 During input restore CD12345 E g CD1345 means that when the input is CD 1 2 3 4 5 calling users No 1 2 3 4 5 Disabled for all restored users NO1 NO3 NO4 and NO5 will is disabled users NO1 NOS not be called Possibility to change input type i e to Setting input type invert E g LIO 0 0 NO normally open LIO Normally open It means that the input is considered inactivated if there is no signal Input levels ul Possibility to change input type i e to Setting input type invert a 1 1 NC normally closed E g LI1 means that input isin normal status when the signal is transmitted The event appears only when the signal disappears IE 0 pp ouma moge IEO disabled Pvz IEO means impulse counting mode is disabled impulsecountinaimode Input counts impulses The number of IE 1
7. confirm Confirmation SMS C12345 E g SC124 means that when users NO1 NO2 and paar E NO4 control the output via call the confirmation Sc 1 2 3 4 5 mode is disabled for Disabled for all A S SMS message informing about the successful users No 1 2 3 4 5 users NO1 NO5 output status change is not sent USER MANUAL ELDES ESIM252 V1 0 27 FOR ADVANCED USERS All these features can be configured using program ELDES Configuration Tool Whewusers The first digit refer to user number The second 1 2 3 4 5 and 0 No 1 2 3 4 5 call the digit refers to command Therefore to set a output is tumed on possibility for user NO1 to turn on the output via call you have to use the command MS10 When users The first digit refer to user number The second Type of control 1 2 3 4 5 and 1 No 1 2 3 4 5 call the MS11 digit refers tocamimand Therefore to eta Via call MS outputis turned off possibility for user NO1 to turn off the output via call you have to use the command MS11 When sers The first digits refer to user number The last digit No 1 2 3 4 5 call refers to command Therefore to set a possibility 1 2 3 4 5 and2 output statis is for user NO1 to turn on the output by one call and then disable it by the next call you have to se the changed TOGGLE command MSi E g to set the timer for 5 hours 10mins 3seconds E for user NO1 you have to use the command __ setting output MS1T5 10 3 oes MS 1 2 3 4 5 and
8. found at the manufacturer s website www eldes lt 32 USER MANUAL ELDES ESIM252 V1 0 33 For notes 34 For notes USER MANUAL ELDES ESIM252 V1 0 35 Made in Lithuania www eldes It
9. hanging the phone or after the end of the call duration 1 min the system will return to the previous state Please refer to ELDES Configuration Tool software Help section for more details on audio feature Up to 2 electric appliances connected to ESIM252 can be controlled from a mobile phone This feature allows to turn on off hea ting lighting lift the gates blinds etc The system ignores incoming calls from unknown phone numbers and SMS messages with wrong password List of other configurable system possibilities Input types Normally open NO Operational only when the signal is transmitted Normally closed NC Operational only when the signal is switched Ways of initiating an event Event when an input is violated Alarm Phone call initiated and or SMS is delivered to user s when the signal is transmitted to an input Event when a zone is restored Restore Phone call initiated and or SMS is delivered to user s when the previously transmitted input signal disappears Impulse counting Input is considered as violated only if the number of the preset impulses in the input is exceeded Max value is 4294967295 impulses Ways of notifying about an event SMS Phone Call The ways of notifying users about events occurred in the particular input can be carried out only SMS only a phone call or a combination of both can be chosen Besides any of the users can be assig
10. sl Ri This means that when afore mentioned user NO1 E Th m s Renae PARES control the output via call the impulse duration is ee i 5hours 10mins and 3seconds and after this period the output returns to the previous state Example of SMS message configuring C1 output XXXX_SMSEXTRA COC1 CE1234 CS123 MS10 MS42 MS1T0 0 40 This message configures C1 output parameters CE1234 means that C1 output can be controlled by users NO1 NO4 NO5 cannot control via call CS123 means that only users NO1 NO2 and NO3 will receive confirmation call MS10 means that when user NO1 calls the system he she enables C1 input but cannot disable it via call The user can disable it via SMS message if he she knows the password MS42 means that when user NO4 calls the system he she will either enable or disable output C1 TOGGLE mode is on It depends on the output status before making a call MS1T0 0 40 means that when user NO1 make a call to the system the output is turned on for 40seconds and then it automatically turns off To see the preset values for any command send SMS message with the same format that you use when changing parameters only Value structure will have no value This does not apply to MS and CT commands When requesting MS and CT parameters MS and CT must be followed by one character user number 1 2 3 4 or 5 XXXX SMSEXTRA COCx Valuel Value2 ValueN XXXX user password COCx outpu
11. the following SMS message YYYY_PSW_XXXX XXXX is any four digit number except four zeros Non numerical characters like dots colons spaces are not allowed YYYY is the old system password If you forgot the password default manufacturer password can be restored see chapter 4 1 for more details 2 3 User Numbers The system Esim252 allows to pre program up to five different mobile numbers which will have access to and control the system NR1 is mandatory while others can be skipped All numbers must be entered starting with international country code e g national code for Lithuania is 370 UK 44 By default the system starts sending all messages and in the event of alarm starts calling on the first number and if the first call is unsuccessful it immediately tries reaching subscriber No2 etc 2 3 1 Saving or Changing Numbers Send SMS message with the following text to Esim252 XXXX NR1 37011111111 NR2 37011111111 NR3 37011111111 NR4 37011111111_ NR5 37011111111 Ones should be replaced with user numbers Numbers don t have to be entered in sequential order right away E g user can enter first and fourth number by sending the following SMS message XXXX_NR1 37011111111_NR4 37011111111 Or individually one number at a time XXXX_NR3 37011111111 Numbers can be changed same way as described above New number will overwrite old one the refore no erasing is necessary
12. 0 1 means that output status is changed for 1 second when user NO1 calls the system MS3T0 0 1 means that output status is changed for 1 second when user NO3 calls the system MS4T0 0 1 means that output status is changed for 1 second when user NO4 calls the system MS5T0 0 1 means that output status is changed for 1 second when user NOS calls the system USER MANUAL ELDES ESIM252 V1 0 19 i FOR ADVANCED USERS All these features can be configured using program ELDES Configuration Tool E g 3 The user wants to connect Esim252 system to the heating system of the house Task No1 Configuring the system so that house heating system is turned on and turned off by the user NO1 via free call This user should also receive free information about successful turning on or turning off of the heating system Confirmation Call 3sek 10sek K y are User E NO1 User A E NO2 As per factory default settings C1 output control via calls is disabled for all users it is necessary to enable this feature and to set the users who will be able to control the output in this case it is user NO1 Besides it is also necessary to set output status for user NO1 when he she calls the system In this case you must set the system so that the output is turned on after one call and turned off after another one Toggle and so on User NO1 needs to enable confirmation call Call Back feature and set the length parameters for
13. 2 3 2 Verification of Saved Numbers To inquire the system about pre programmed numbers send the following SMS message XXXX_HELPNR The system will reply with all pre programmed numbers 2 3 3 Deletion of Saved Numbers To erase NR2 NR5 send the following SMS message XXXX_NR2 DEL_NR3 DEL_NR4 DEL_NR5 DEL E g XXXX_NR3 DEL The system will not allow erasing first number NR1 It can only be modified 2 4 Date and Time Settings Itis important to set correct date and time so that the system can send reports at specified times Date and time can be set by sending the following format SMS message XXXX_MMMM mn dd_va mi where MMMM means year mn month dd day va hour mi minutes E g XXXX_2009 01 01_14 15 USER MANUAL ELDES ESIM252 V1 0 9 3 Additional System Capabilities 3 1 Renaming Input Alarm Restore Texts amp Output Hames Manufacturer initially set the following input alarm restore texts and output names input Z1 alarm text Zone1 Alarm restore text Restore1 input Z2 Zone2 Alarm restore text Restore2 0 input Z3 Zone3 Alarm restore text Restore3 input Z4 Zone4 Alarm restore text Restore4 input Z5 Zone5 Alarm restore text Restore5 output C1 name Controller1 output C2 name Controller2 E g in case input Z1 is violated the system sends SMS message with the text Zone1 Input alarm text Input alarm text is changed by sending the following S
14. 5 means that the output is turned on for 8 hours and 5 minutes and after that it turns off and turns on again at 20 15 the following day etc UC2 means that information about turning on off is sent to user s No2 telephone CS1 means that the user is notified by a callback about output turning on the duration of the call is set by parameter CT13 CT13 means that the system calls for 3 seconds CT06 means that when the output turns off after 8 hours and 5 minutes the user is notified by a call again but call duration is 6 seconds SE1 means that the user is also notified about relay enabling by SMS message To see the preset values for any command send SMS message with the same format that you use when changing parameters only Value structure will have no value XXXX SMSEXTRA OCTE1 Valuel Value2 ValueN XXXX user password OCTEx output control by event time value can be OCTE1 C1 output or OCTE2 C2 output Value structure is Cn where Cn is command name 2 letters E g XXXX_SMSEXTRA OCTE1 CB CT SB USER MANUAL ELDES ESIM252 V1 0 31 4 Appendix 4 1 Restoring Default Parameters To restore default parameters disconnect power supply and USB connector short circuit connect connectors D1 and D2 power up the system for 5 seconds disconnect power supply e remove short circuit from connectors D1 and D2 power up the system parameters restored to default 4 2 ELDES Configuration Tool Softw
15. CT06 SB1 This message configures C2 output parameters when controlled via SMS messages CB1 means that when the user turns on off output C2 he she receives a short confirmation call Call Back CT13 means that when the output is turned on confirmation call duration is 3 seconds CT06 means that when output is turned off confirmation call duration is 6 seconds SB1 means that confirmation message is sent informing about turning the output on off To see the preset values for any command send SMS message with the same format that you use when changing parameters only Value structure will have no value XXXX_SMSEXTRA 0CSx Valuel Value2 ValueN XXXX user password OCSx output control by SMS value can be OCS1 C1 output or OCS2 C2 output Value structure is CnVal when Cn is command name 2 letters E g XXXX_SMSEXTRA OCS2 CB CT SB USER MANUAL ELDES ESIM252 V1 0 29 FOR ADVANCED USERS All these features can be configured using program ELDES Configuration Tool 3 9 2 3 Output ontrol settings by event time This chapter describes a possibility to control C1 and C2 outputs using timetable scheduler It can be for instance atomatic tur ning on every day at 18 00 and turning off after 5 hours The parameters are changed by sending the following SMS message to the system Esim252 XXXX SMSEXTRA OCTEx Valuel Value2 ValueN XXXX user password OCTEx output contr
16. MS mesaage XXXX_Z1 NewAlarmText Z2 NewAlarmText Z23 NewAlarmText Z4 NewAlarmText Z25 NewAlarmText E G XXXX_Z1 Intrusion though the door Z2 Fire sensor alarm Texts can be changed all at once for all inputs several of them or one by one Maximum text for one input text is 24 characters The space is equal to one character Each new text must be followed by a semi colon As semi colon is used for separating texts for different inputs It cannot be used in the middle of alarm texts it can only be used at the end Texts cannot be the same as configuration and control com mands such as ON OFF STATUS etc Input restore text If you want to be notified by an SMS message when a violated zone is restored Restore mode must be turned on The mode is turned on by sending a particular SMS command Please refer to chapter 3 9 or configuration program Input restore text is changed by sending the following SMS mesaage XXXX_ZR1 NewRestoreText ZR2 NewRestoreText ZR3 NewRestoreText ZR4 NewRestoreT ext ZR5 NewRestoreText Output name can be changed by sending the following SMS message XXXX_Cx NewControllerName x output number possible values 1 C1 or 2 C2 Output name cannot be followed by a semi colon You cannot change input alarm restore text and out put names at the same time E g XXXX_C1 PUMP 3 2 Enabling Disabling Inputs NOTE Manufacturer set all the inputs activated i
17. Z5 Z4 Low level input Z4 Z3 Low level input Z3 Z2 High level input Z2 Z1 Low level input Z1 USER MANUAL ELDES ESIM252 V1 0 LED indicators functionality LED1 Indicates SIM card status LED2 status Meaning LED2 Indicates network status LED1 status Meaning OFF Blinking 3 times per second No network connection Poor network connection OFF SIM card is working properly Blinking 1 time per second Medium network connection ON SIM card error 1 5 Connection Circuit USEFUL INFORMATION When choosing GSM provider it is worth inquiring whether the service is used in security application assuring fast and reliable SMS message delivery and phone call connection USEFUL INFORMATION When choosing GSM cellular provider it is worth inquiring whether the service is used in security application assuring fast and reliable SMS message delivery and phone call connection Esim252 and alarm system COM must be connected ON Excellent network connection Inputs Z1 Z3 Z4 Z5 are connected to alarm system outputs if outputs are implemented as open collector circuit or any other circuit and if it commutes with COM It is also possible to connect Z1 Z3 Z4 Z5 inputs to for instance motion sensor or any other sensor as well as automatics device provided the inputs are commuted with COM Input Z2 is commuted with a high level impulse Impulse dura
18. are To configure the system quicker and easier as well as use more system capabilities use configuration software ELDES Configuration Tool which can be downloaded from our website www eldes lt Before configuring ESIM252 via USB cable or remote configuration over GPRS please read ELDES Configuration Tool user guide available in HELP section of the software 4 3 Technical Support Indication Possible reason Indicator is off or not blinking no external power supply circuit not properly connected blown fuse no network signal Indicator blinking several times per SIM card is not inserted second PIN code hasn t been disabled Sim card not active System does not send any SMS SIM card account depleted messages and or does not ring incorrect SIM central number no network signal user number is not programmed or disabled access from unknown numbers Received SMS message Incorrect incorrect syntax Format extra space symbol left in SMS message No sound while listening to remote microphone not connected microphone microphone connection incorrect While listening to remote micropho Change the position of the microphone or its lead in ne outside noise heard respect of system panel Ifyour problem could not be fixed by the self guide above please contact your distributor or manufacturer tech support by email support eldes lt More up to date information about your device and other products can be
19. chnical Specifications Electrical and mechanical specifications Supply voltage 10 24V 50Hz 200mA max 10 24V 200mA max Current used in standby mode 50mA max GSM modem frequency 850 900 1800 1900 MHz Number of low level negative inputs 4 Number of high level positive inputs 1 Allowable low level negative input values Voltage 0 1 6V current 0 8 0 4mA Allowable high level positive input values Voltage 5 50V current 0 17 1 7mA Number of outputs 2 Output type Relay Normally open NO Relay output maximum commutating values 24V 77 1A 24V 50Hz 0 5A Dimensions 82x63x20mm Operating temperature range 20 55 C 1 4 Connector Functionality LED1 LED2 O oee DEFAULT D1 D2 AC DC RELAY1 Picture 1 30 55 C with limitations Short explanation of the main units GSM MODEM GSM network 850 900 1800 1900 MHz modem SIM CARD SIM card LED Light emitting diodes indicator DEFAULT Connectors D1 and D2 for restoring default settings ANT GSM antenna SMA type connector USB Mini USB connector Fl Fuse Connector functionality Labeling Explanation AC DC Power supply pins RELAY1 Dry relay contact Normally open NO RELAY2 Dry relay contact Normally open NO COM Common pin Z5 Low level input
20. d for NO1 only a First of all alarm system unit must be programmed in the way so that when security sensors are violated the signal must be transmitted to alarm system system unit output PGM b Output PGM is connected to ESIM252 input Z1 c The following two configuration SMS messages must be sent to Esim252 system XXXX_SMSALL ON where SMSALL enables mandatory SMS message delivery for all users XXXX SMSEXTRA Z1 SC345 CC2345 Where SC345 means that alarm SMS message sending is disabled for users NO3 NO4 and NOS after input Z1 is violated CC2345 means that alarm calls are disabled for all users except NO1 after input Z1 zone is violated 18 A FOR ADVANCED USERS A All these features can be configured using program ELDES Configuration Tool Task NO2 Configuring the system so that house gates could be opened via free calls by the housekeeper NO1 and his family members NO3 NO4 and NO5 After every successful gate opening the user NO5 wants to receive a confirmation call Call Back the duration of which is 3 seconds and the user NO3 wants to receive a confirmation SMS message AAA Control A A Call Perey Confirmation AAA ae Family member SMS NO3 Housekeeper NO1 N Y Gate controller Family member NO4 lecrasaes Confirmation Family member NO5 As per factory default settings C1 output control via calls is disabled for all users it i
21. des GSM CONTROL SYSTEM ESIM252 User Manual v1 0 Safety instructions Please read and follow these safety guidelines and assembly instructions in order to maintain safety of operators and people around Ii eb ee Copyright GSM control system Esim252 further referenced as the system contains an integrated radio transceiver operating in GSM 850 900 1800 1900 MHz bands Don t use the system where it can interfere with other devices and cause any potential danger Don t mount the system next to medical equipment or devices if they require so Don t use the system in hazardous environment Don t expose the system to high humidity chemical environment or mechanical impacts Don t attempt to personally repair the system System label is on the bottom side of the device System Esim252 is a device mounted in limited access areas Any system repairs must be done only by qualified safety aware personnel Mains power must be disconnected before any installation or tuning work starts The system installation or maintenance must not be done during stormy conditions The system must be powered by main 10 24V 50Hz 200mA AC or 10 24V 200mA DC power supply which must be approved by LST EN 60950 1 standard and be easily accessible nearby the device When connecting the power supply to the system switching the terminals places does not have any affect Any additional devices linked to the system Esim252 computer sensors relay
22. e in mode ON USEFUL INFORMATION The inputs can be enabled disabled together or separately one by one Enabling Input Any input can be enabled by sending the following SMS message XXXX 21 0N 22 0N Z3 0N Z24 10 Disabling Input Any input can be disabled by sending the following SMS message XXXX_21 0FF 22 0FF Z3 0FF 24 0FF Z5 0FF E g XXXX_Z2 ON or XXXX_WINDOWS ON or XXXX_Z2 OFF or XXXX_WINDOWS OFF 3 3 Info on Status SMS The system ESIM252 can any time be inquired about signal strength and the status of inputs at the time when SMS message is sent At the same time system test is performed If the answer to the request has been received it means the system finely operates It is also useful for those using prepayment service you can check if the credit in the account is sufficient for sending an SMS message Send the following SMS message XXXX_INFO The reply SMS will have following info e g 2008 08 07 11 15 Signal strength satisfactory Z1 O0K ALARM Z2 0K ALARM Z3 OK ALARM Z4 0K ALARM Z5 0K ALARM where OK means that there is no alarm in a particual input restored ALARM the particular input is violated By default this status SMS message will be sent daily at 11 00 in the morning These parameters can be configured by sending the following SMS message XXXX_INFO PP VV PP message period in days valid values 00 10 VV time when message is sent valid values 00 23 E
23. eature is enabled it will not be possible to stop calling the next user in the sequence even if the call is answered To disable this function send the following SMS message XXXX_CALLALL OFF If you want to configure calling only to particular users or only for particular zones refer to chapter 3 9 or use configuration program ELDES Configuration Tool 3 9 Configuration for advanced users All features described in chapter 3 9 of the user manual can be configured using ELDES Configuration Tool software In case if there is no possibility of connecting the device to the computer via USB or if you want to change the settings remotely you can do this via remote configuration feature over GPRS using ELDES Configuration Tool or via SMS messages We recommend changing the settings by SMS only for advanced users USER MANUAL ELDES ESIM252 V1 0 13 i FOR ADVANCED USERS All these features can be configured using program ELDES Configuration Tool E g 1 The user wants to connect Esim252 system to an existing alarm in a building where enterprise A and and enterprise B work Both enterprises use the same alarm system that has two inputs The alarm system has 5 outputs PGM Task NO1 Configuring the system so that the director of a particular enterprise is informed about security arming depending on which enter prise employee armed the alarm system The director of enterprise A NO1 wants to receive an SMS me
24. elivery of the SMS message it is necessary to enable mandatory SMS message delivery see more in chapter 3 7 and to remove the users who should not receive alarm messages Besides as per factory default settings calling feature in the case of alarm is also enabled for all users therefore call function must be disabled for all users except users NO3 and NO4 As per factory default settings in the case of alarm the system rings until the first answered call therefore in this case nothing should be configured a First of all alarm system unit must be programmed in the way so that when security sensors of enterprise A are violated the signal is transmitted to alarm system unit s output PGM4 b Output PGM4 is connected to ESIM252 input Z4 c The following configuration SMS messages must be sent to Esim252 system XXXX_SMSALL ON where SMSALL enables mandatory SMS message delivery feature for all users XXXX_SMSEXTRA Z4 SC125 CC125 Where SC125 means that alarm SMS message delivery feature is disabled for users NO1 NO2 and NOS after input Z4 is violated CC125 means that alarm calls are disabled for users NO1 NO2 and NOS after input Z4 is violated 16 A FOR ADVANCED USERS A All these features can be configured using program ELDES Configuration Tool Task NO4 Configuring the system so that the intrusion to enterprise B premises is reported to the janitor NO3 and enterprise B employee NO5 by SMS m
25. em you can enable these 3 functions enable disable enable disable for a certain period or change output status with every call i e one call enables the status the next one disables it etc The parameters are changed by sending the following SMS message to the system Esim252 XXXX SMSEXTRA COCx Valuel Value2 ValueN XXXX user password COCx output control by call value can be COC1 C1 output or COC2 C2 output ValueN structure is CnVal when Cn is command name 2 letters and Val its value Value CnVal table of values Cn command Val possible Command Initial factory name 2 command DR Comments E description default values letters meaning Control vib call mode E g CE25 means that users NO2 and NO5 will be CE 1 2 3 4 5 is enabled for users bist tral th ure fi Enabling control No 1 2 3 4 5 able to control the output via call viaicall Conio Mia call modes A CD12345 E g CD25 means that output control via call is CD 1 2 3 4 5 is disabled for users Disabled for all disabled for users NO2 and NO5 No 1 2 3 4 5 users NO1 NO5 A E g CS124 means that when users NO1 NO2 and Confirmation call z z x E NO4 control the output via call they will be notified A cs 1 2 3 4 5 mode is enabled for Enabling about a successful output status change by a eee users No 1 2 3 4 5 5 disabling confirmation call confirmation call i CC12345 E g CC124 means that when users NO1 NO2 and Confir
26. er supply usually the security system AUX output is used 4 When AC power supply ground transformer is used connect according to circuit no 3 In this case you do not need to con nect any other power supplies 5 The system will start in less than a minute LED2 indicator should be blinking or be ON indicating connection to GSM USER MANUAL ELDES ESIM252 V1 0 7 2 System Pre operation and the Main Control Commands VERY IMPORTANT Underscore symbol _ in this manual is used to represent space When writing SMS messages every underscore symbol should be replaced by single space symbol XXXX means password Do not leave any space at the beginning and the end of the message To set ESIM252 system parameters easier and quicker you can use the computer USB cable or remote device configuration over GPRS connection and configuration software ELDES Configuration Tool For more details please refer to chapter 3 2 2 1 Selecting device language and verification of SMS central number The language in which the device communicates with the user can be chosen before changing factory default password To change the language in the system that is already configured reset default settings as described in 3 1 appendix Send SMS message with the required language code to the number of the SIM card inserted in Table of Language Code Esim252 possible aha languages ithuanian E g if you want to set the English language send
27. essages and calls and the director of enterprise B NO2 receives SMS message only Enterprise B employee NO5 must receive the phone call even in the case when the janitor NR3 answers the call Director A NO1 Enterprise A Enterprise B Director B NO2 Worker A NO4 Worker B NO5 8 09 Anm Janitor SMS Calls NO3 As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS message it is necessary to enable mandatory SMS message delivery see more in chapter 3 7 and to remove the users who should not receive alarm messages Besides as per factory default settings calling feature in the case of alarm is also enabled for all users therefore call function must be disabled for users NO1 NO2 and NO4 and left enabled for users NO3 and NO5 Also itis necessary to enable mandatory calling feature for all preset users see more in chapter 3 8 a First of all alarm system unit must be programmed in the way so that when security sensors are violated the signal must be transmitted to alarm system unit s output PGM5 b Output PGMS is connected to ESIM252 input Z5 c The following three configuration SMS messages must be sent to Esim252 system XXXX SMSALL ON where SMSALL enables mandatory SMS message delivery feature for all users XXXX_CALLALL ON where CALLALL enables mandatory cal
28. hen output is turned off The system will call for 8 seconds The user receives a confirmation call O s when the output is CTO8 turned off s call time in seconds Setting the user who receives Sets which user is E g UC2 means that all confirmations will be confirmations UC 123415 notified about period UC1 delivered to user No2 about period start end Only one user can be selected start end SS1 means that the preset user is notified about pects ate notice period start of turning on off output by SMS Setting l aboni al by message The user is set by using UC command confirmation ss 9 See below SMS message for ified period start Users are not notifie SSO means that nobody is informed about period 0 about period start by sso start by SMSimessage SMS message y sisi Usaisenautetin SE1 means that the user is also notified about Setting l pases output turning off by SMS message confirmation SE SMS message SMS message for Users are not notified aah A period end 0 about periodiendiby SEO SEO means that nobody is informed about period end by SMS message SMS message Example of output C1 configuration for a schedule XXXX_SMSEXTRA OCTE1 WT20 15 ST1 PT8 0 UC2 CS1 CT13 CT06 SE1 This message configures C1 output parameters using a schedule WT20 15 means that output turning on time is set for 20 15 every day ST1 means the user set the output to turn on on that time PT8
29. input 1C555 means that the users will receive the alarm when 555 impulses are transmitted to the input Immediately after the alarm the counter resets and starts counting impulses until their number reaches 555 To see the preset values for any command send SMS message with the same format that you use when changing parameters only Value structure will have no value XXXX SMSEXTRA Zn Valuel Value2 ValueN XXXX user password Zn possible values Z1 Z2 Z3 Z4 Z5 Define the number of the input being changed Value structure is Cn where Cn is command name 2 letters E g XXXX_SMSEXTRA Z2 SS SC CC SE SD 26 i A FOR ADVANCED USERS A All these features can be configured using program ELDES Configuration Tool 3 9 2 Additional possibilities of controlling and configuring outputs C1 and C2 Normally C1 and C2 outputs can be controlled only by SMS message as described in chapter 3 6 i e by enabling disabling it for a permanent status or for a preset period However you can configure automatic enabling and disabling for a particular hour or control this function by a call 3 9 2 1 Settings of an output controlled by calls When calling on the number of system ESIM251 the call is rejected and no control operations are run However when a special mode is enabled C1 C2 outputs can be controlled by a call It can be controlled by all users NO1 NO5 several users or only one of them By calling the syst
30. ker Gas boiler NO1 5 Worker E NO2 NO3 As per factory default settings C1 output control via calls is disabled for all users it is necessary to enable this feature and to set the users who will be able to control the output Besides it is also necessary to set output status for every user when he she makes a call to the system In this case the output must be turned on and the duration must be 2 seconds afterwards the output returns to the previous state a First of all ESIM252 system output has to be connected to automatic system unit b The following configuration SMS message must be sent to Esim252 system XXXX_SMSEXTRA COC1 CE123 MS10 MS20 MS30 MS1T0 0 2 MS2T0 0 2 MS3T0 0 2 MS10 means that the output is activated when user NO1 calls the system MS20 means that the output is activated when user NO2 calls the system MS30 means that the output is activated when user NO3 calls the system MS1T0 0 2 means that output status is changed for 2 seconds when user NO1 calls the system MS2T0 0 2 means that output status is changed for 2 seconds when user NO2 calls the system MS3T0 0 2 means that output status is changed for 2 seconds when user NO3 calls the system 24 gt 1 FOR ADVANCED USERS A I All these features can be configured using program ELDES Configuration Tool L eee a 3 9 1 Additional possibilities of configuring input alarm and restore During the alarm the system call
31. ling feature for all users XXXX SMSEXTRA Z5 SC14 CC124 where SC14 means that alarm SMS message sending feature is disabled for users NO1 and NO4 after input Z5 is violated CC124 means that alarm calls are disabled for users NO1 NO2 and NO4 after input Z5 is violated USER MANUAL ELDES ESIM252 V1 0 17 i FOR ADVANCED USERS All these features can be configured using program ELDES Configuration Tool E g 2 The user wants to connect ESIM252 system to the outputs PGM of an existing alarm system House area is entered through automatically controlled gates There are 5 users in total NO1 is the housekeeper NO2 is a neighbour NO3 NO5 are family members Task NO1 Configuring the system so that house alarm activation is reported to the housekeeper NO1 by SMS message and a call as well as to the neighbour NO2 but by SMS message only Housekeeper NO1 Neighbour NO2 Family members NO3 NO4 NO5 As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS message it is necessary to enable mandatory SMS message delivery see more in chapter 3 7 and to remove the users who should not receive alarm messages Besides as per factory default settings calling feature in the case of alarm is also enabled for all users therefore call function must be disabled for users NO2 NO5 and left enable
32. m SMS message sending is disabled for all users NO1 NOS5 after input Z2 is violated CC1345 means that all alarm calls are disabled for users NO1 NO3 NOS after input Z2 is violated 14 A FOR ADVANCED USERS A All these features can be configured using program ELDES Configuration Tool Task NO2 Configuring the system so that the janitor NO3 is notified by by SMS message and call about the violated PIR movement sensor s input in the secured area and when the sensor s input is restored the janitor receives SMS message only Director A NO1 Director B NO2 Worker A NO4 Worker B NO5 3 3 0 0 Janitor RFS Janitor SmMs Calis NO3 As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS message it is necessary to remove the users that should not receive any alarm messages Besides as per factory default settings calling feature in the case of alarm is also enabled for all users therefore call function must be disabled for all users except user NO3 SMS message sending feature must also be enabled for user NO3 when input Z3 is restored a First of all alarm system unit must be programmed in the way so that when PIR movement sensor s input is violated output PGM3 is activated b Output PGM3 is connected to ESIM252 input Z3 c The following configuration SMS message must be
33. mation call k A CallBack ES NO4 control the output via call the call confirming GG 1 2 3 4 5 mode is disabled for i a as users No 1 2 3 4 5 Disabled for all about a successful output status change is disabled RS users NO1 NO5 and users will not receive calls The first number refers to user number The second Confirmation call CT112 number is a command and the last number refers is made for users CT212 to call time in seconds 1 2 3 4 5 1 s No 1 2 3 4 5 when the CT312 E g CT412 means that if confirmation call mode ouput is turned on CT412 is enabled user NO4 will receive a call if he she is c i s call time in seconds CT512 trying to turn on the output onfirmation call duration cT The system will call for 2 seconds i The first number refers to user number The second paramerers Confirmation call CT108 number is a command and the last number refers is made for users CT208 to call time in seconds 1 2 3 4 5 0 s No 1 2 3 4 5 when the CT308 E g CT408 means that if confirmation call mode output is turned off CT408 is enabled user NO4 will receive a call if he she is s Call time in seconds CT508 trying to turn off the output The system will call for8 seconds E g 55124 means that when users NO1 NO2 and Confimaton sus ee a Enabling ss 1 2 3 4 5 mode is enabled for R P J2 REE confirmation SMS message disabling users No 1 2 3 4 5 EA Before that the user has to turn on control from a SMS particular number by using CE command SMS
34. naag the following SMS message EN english EN 4 30 60 seconds later you should get an SMS message russian RU i 3 English language confirmed Go to chapter 2 2 upon reception of this message Otherwise check for network connection and call Esim252 system from your mobile and wait until the system drops the call You should get an SMS message asking to change default password Otherwise check for network connection and change SMS central number SMS central number is saved in SIM card therefore if SIM card has been used to send SMS messages with a mobile phone then you don t need to change SMS central number Often SMS central number is already saved in SIM card by cellular operator Central number can be entered by sending SMS message XXXX_SMS_ 37011111111 XXXX is a password Default password is four zeros 0000 SMS central number is provided by cellular network provider Example 0000_SMS_ 37069899992 Message should be sent to the number of SIM card which is placed into the system If all went correct the system will send a messa ge SMS central number has been successfully changed to 37011111111 2 2 Password Change All SMS commands start with a password please memorize it Manufacturer default password is our zeros 0000 which is necessary to change Manufacturer default password can be changed by sending the following SMS message to Esim252 0000 _PSW_XXXX To replace your password send
35. nd NO4 SMS messages will still be delivered CC25 means that during the alarm calling function is disabled for users NO2 and NOS As per manufacturer default settings calling function is preset for all users therefore users NO1 NO3 and NO4 will still be called SE1234 means that SMS restore message sending is enabled for users NO1 NO2 NO3 and NO4 This means that when input Z1 is restored after previous violation these users will be informed about this restore event by SMS message However alarms and restore SMS messages will be sent until the first successful delivery To enable mandatory message delivery to all users you should use the command XXXX_SMSALL ON as described in chapter 3 7 CE4 means that during input Z1 restore only user NO4 is called LE1 means that input type for input Z1 will be inverted i e the previous NO is changed to NC normally closed This means that the input is violated only when the signal disappears and the input is restored only in case when the signal appears DV900 means that input Z1 is violated only if the signal is suspended at least for 900ms Please note that input type was inverted to NC If inversion was not possible this DV900 command would mean that the signal transmitted must not be shorter than 900ms 2 Example of SMS message configuring Z2 input XXXX SMSEXTRA Z2 1E 1 1C555 This message configures Z2 input parameters 1E1 means that impulse counting mode is enabled for Z2
36. ned to be informed in case a particular input is violated or restored or both Various combinations of informing can be assigned for each user and input When features SMS All and Call All are enabled the system sends SMS messages and rings to all preset users starting with User1 despite the fact that the call was answered or rejected etc Examples User NR1 wants to be informed by SMS in case input Z3 is violated but does not want to be informed when input Z3 is restored User NR3 wants to be informed by SMS and phone call in case input Z2 is violated but wants to be informed only by SMS in case of Z2 restore event Ways of controlling outputs relays Turning on off by SMS The outputs can be turned on off by sending the command by SMS message You can turn on off 1 for a permanent status 2 for a set period 3 for a set hour 4 repeating turning on off Turning on off by a call The outputs can be turned on off by calling You can turn on off 1 for a permanent status 2 for a set period 3 toggle output status changes after each call Automatic turning on at the preset hour Outputs can be turned on for a set period at a set hour E g the relay is turned on at 18 00 and it is on for 5 hours After 5 hours it turns off automatically notifying the user about that Event log Event log feature List of occurred events by date and time zone alarm restore output on off etc 1 3 Te
37. neis 28 3 9 2 3 Output control settings by event time 30 3 92 Appendix 4 1 4 2 4 2 Restoring Default Parameters mn 32 ELDES Configuration Tool software Technical Support 1 General Information 1 1 Function ESIM252 is a micro controller based device intended to inform users about the alarm in automatic or security systems In addition it can control up to two electric appliances 1 2 Operation Description Description of factory default settings GSM control system ESIM252 operates over GSM network 24 7 i e it always reacts to the incoming signal In case any input is violated the system sends an SMS message and or calls to the preset user phone numbers SMS message with the name of the violated zone will continue to be sent until successful delivery to one of the users or until it is delivered to all users The system continues to call until one of the five users answers the call rejects the call or until the call is ended by the GSM service provider If the user answers the call the system activates microphone must be connected to ESIM252 for listening on what is happening in the secured premises When using audio feature in case of input alarm or restore event the user will be able to listen to particular sound record uploaded to the ESIM252 device memory After the end of the sound record the system activates the microphone for listening on what is happening in the secured premises After
38. ol by event time value can be OCTE1 C1 output or OCTE2 C2 output Value structure is CnVal when Cn is command name 2 letters and Val its value Value CnVal table of values Cn command Nelle possible Command Initial factory name 2 ioe Comments command description default values letters P meaning h m Indicates the time for E g WT18 10 means event start time It can be Setting enabling WT enabling or disabling enabling and disabling It depends on the set disabling time h hour m output in hours and ST value A period PT must also be indicated minutes minutes otherwise relay status will not change See below ST1 Sai 1 Relay is tumedon E g ST1 means that when the set time comes the Calls CMe y Output is output is turned on by WT command status whether t ee urned on itis enabled or ST disabled z 0 Relavis turned off E g STO means that when the set time comes the u output is turned off by WT command h m Indicates the time in E g PT1 20 means that after automatic enabling Setting the period PT hours and minutes for disabling which is indicated in WT command relay of turning on off h hour m which output status is status is changed to opposite for 1 hour and 20 minutes changed minutes e CS1 means that the preset user is informed about Users are notified E o a A the period start of output turning on or off via 1 about period start by A 7 2 short call The user is set by using UC command
39. ou want to use more capabilities of the outputs such as TOGGLE automatic output control at a particular use configuration software ELDES Configuration Tool or refer to chapter 3 9 2 3 7 SMS Message Delivery to Multiple Users Upon activated alarm in security system ESIM252 SMS messages are repeatedly sent until first successful delivery to one of the users The system starts with NR1 and if delivery fails it follows with NR2 etc It is also possible to set the system so that it sends SMS message to all preset users in the system To enable this function send the following SMS message XXXX_SMSALL ON To disable this function send the following SMS message XXXX_SMSALL OFF If you want to configure SMS message delivery only for particular users or only for particular inputs please refer to chapter 3 9 or use configuration program ELDES Configuration Tool 3 8 Calling all users During the alarm Esim252 system starts calling NR1 If the call to NR1 was unsuccessful or the subscriber was out of network co verage the call is forwarded to NR2 etc If the user rejected the call or answered te call during the alarm the system stops calling However you can set the system to call all users entered in the system regardless of the fact whether the user answered or rejected the call was out of network coverage or was engaged To turn on this feature send the following SMS message XXXX_CALLALL ON ATTENTION When this f
40. quirements and other relevant provisions of Directive 1999 5 EC The declaration of conformity may be consulted at www eldes lt Limited Liability The buyer must agree that the system will reduce the risk of fire theft burglary or other dangers but does not guarantee against such events ELDES UAB will not take any responsibility regar 1 ding personal property or revenue loss while using the system ELDES UAB responsibility according to local laws does not exceed value of the purchased system ELDES UAB is not affiliated with GSM operators providing cellular services therefore is not respon sible for the quality of cellular services Manufacturer Warranty The system carries a 24 month warranty by the ma nufacturer ELDES UAB Warranty period starts from the day the system has been purchased by the end user The warranty is valid only if the system has been used as intended following all guidelines listed in the manual and within specified operating conditions Receipt with Eb purchase date must be kept as a proof The warranty is voided if the system has been exposed to mechanical impacts chemicals high humidity fluids corrosive and hazardous environ ment or other force majeure factors Package Content The system Esim252 Esim252 user manual GSM amMenNa siasii Fastening HOlders ssseesscccccssseeees About User Manual This document describes GSM control system Esim252 i
41. s and sends SMS messages to all preset users until the first successful SMS delivery or a call rejected by the user The users are not notified about input restore Input delay due to interference is 600ms i e only the impulse that is longer than 600ms is considered an event All inputs Z1 Z5 are enabled Impulse counting mode is turned off To change these settings send the following SMS message XXXX_SMSEXTRA Zn Valuel Value2 ValueN XXXX user password Zn possible values Z1 Z2 Z3 Z4 Z5 Define the number of the input that is changed Value structure is CnVal where Cn means command name 2 letters and Val its value digits without spaces or punctuation marks Value CnVal Table of values Cn command Vala possible ees Initial factory command Command description Comments name 2 letters ve default values meaning During the alarm SMS S512345 E g SS25 means that during alarm SMS SS 1 2 3 4 5 message will be sent to Enabled for all message sending is enabled for users NO2 users NO 1 2 3 4 5 users NO1 NO5 and NO5 During the alarm SMS sc 12345 message sending to E g SC2 means that SMS message sending AS users No 1 2 3 4 5 will be will be disabled for user NO2 Alarm disabled figuration saka PS During the alarm the CS12345 Enabled ES 1 2 3 4 5 system will call users for all users E g CS124 means that during alarm calls are No 1 2 3 4 5 NO1 NO5 enabled for users NO1
42. s etc must be approved by LST EN 60950 1 standard External power supply can be connected to AC mains only inside installation room with automatic 2 pole circuit breaker capable of disconnecting circuit in the event of short circuit or over current condition Open circuit breaker must have a gap between con nections of more than 3mm and the disconnection current 5A AC230V 50H2 DC 24V USB cable Fuse F1 model MINISMDCO5OF 0 5A Blown fuse cannot be replaced by the user and the replacement fuses have to be exactly the same as indicated by the manufacturer The device is fully turned off by disconnecting 2 pole switch off device of the external power supply or any other linked device that the system Esim252 is powered from If you use security class computer for setting the parameters it must be connected to earth The WEEE Waste Electrical and Electronic Equipment marking on this product or its documentation indicates that in the EU the product must not be disposed of together with household waste O ELDES UAB 2009 All rights reserved It is strictly forbidden to copy and distribute information in this document or pass to a third party without an advanced written authorization from ELDES UAB ELDES UAB reserves the right to update or modify this document and or related products without a warning Hereby ELDES UAB declares that this GSM CONTROL SYSTEM Esim252 is in compliance with the essential re
43. s necessary to enable this feature and to set the users who will be able to control the output Besides it is also necessary to set output status for every user when he she makes a call to the system In this case the output must be turned on and the duration must be 1 second afterwards the output returns to the previous state Call Back feature must be enabled for user NO5 and it is necessary to choose the length parameters for that call Also confirmation SMS messages have to be enabled for user NO3 a First of all Esim252 system relay output has to be connected to the connectors of gate control unit b The following configuration SMS message must be sent to Esim252 system XXXX_SMSEXTRA COC1 CE1345 CS5 CT513 83 MS10 MS30 MS40 MS50 MS1T0 0 1 MS3T0 0 1 MS4T0 0 1 MS5T0 0 1 where COC1 means C1 output control by call is enabled for users NO1 NO3 NOS CS5 means that Call Back feature is enabled for user NO5 after output C1 status changes CT513 means that user NO5 will receive a confirmation call when the output gets activated and call duration is 3 seconds S53 means that user NO3 will be informed about output C1 status change by SMS message MS10 means that the output is activated when user NO1 calls the system MS30 means that the output is activated when user NO3 calls the system MS40 means that the output is activated when user NO4 calls the system MS50 means that the output is activated when user NOS calls the system MS1T0
44. sary to remove users NO1 and NO3 and disable alarm calls for all users It is also necessary to enable impulse counting mode for Esim252 input Z3 and set the number of expected impulses a First of all a signal indicating PUMP triggering is connected to Esim252 input Z3 b The following configuration SMS message must be sent to Esim252 system XXXX_SMSEXTRA Z3 SC13 CC123 1E1 1C10 where SC13 means that alarm SMS message sending is disabled for users NO1 NO3 after input Z3 zone violation CC123 means that alarm calls are disabled for users NO1 NO2 and NO3 after input Z3 violation We make an assumption that users NO4 NO5 were not entered to the system at all IE1 enables impulse counting mode for input Z3 C10 means that the alarm is given to input Z3 after 10 impulses are transmitted USER MANUAL ELDES ESIM252 V1 0 23 i FOR ADVANCED USERS All these features can be configured using program ELDES Configuration Tool E g 4 The company taking care of automatic systems needs to have information about critical breakdowns of mechanisms and has to quickly react and eliminate the breakdown There are three members of operating personnel NO1 NO2 and NO3 Task No3 Configuring the system so that operating personnel members NO1 NO2 and NO3 can reboot the hanged automatic control system without going to the object but via a short call to Esim252 system gt amp Wor
45. seconds otherwise the system will stop trying and return to previous state 3 6 Managing C1 amp C2 Outputs Timer GSM control system ESIM252 contains two outputs C1 and C2 It can be used to control various electric appliance such as electric pumps heating lighting etc When the output s is turned on the relay connectors of the output are in NC state normally closed The output is turned on by sending the following SMS message XXXX_Cx ON x output number possible values 1 C1 or 2 C2 The output is turned off by sending the following SMS message XXXX_Cx OFF x output number possible values 1 C1 or 2 C2 Instead of C1 or C2 it is also possible to use real output name E g XXXX_PUMP ON Timer GSM control system ESIM252 has internal timer This feature allows any output to be turned on or off for a specified time period The following SMS command should be sent XXXX_Cx ON OFF vv mm ss x output number possible values 1 C1 or 2 C2 ON output enabled OFF disabled vv hours valid values 00 23 mm minutes valid values 00 59 ss seconds valid values 00 59 It is not allowed to have all values equal zeros Zeros it is not allowed to have all values equal E g to switch the pump on for 01 minutes and 23 seconds send SMS XXXX_PUMP ON 00 01 23 If the pump was enabled before and user want to disable it for 01 minute and 23 seconds send SMS XXXX_PUMP OFF 00 01 23 If y
46. sent to Esim252 system XXXX_SMSEXTRA Z3 SC1245 CC1245 SE3 where SC1245 means that alarm SMS message sending to users NO1 NO2 NO4 and NOS is disabled after input Z3 is violated CC1245 means that alarm call feature is disabled for users NO1 NO2 NO4 and NOS after input Z3 is violated SE3 means that SMS message sending feature is enabled for user NO3 after Z3 input is restored USER MANUAL ELDES ESIM252 V1 0 15 i FOR ADVANCED USERS All these features can be configured using program ELDES Configuration Tool E g 1 The user wants to connect ESIM252 system to an existing alarm system in a building where enterprise A and enterprise B work Both enterprises use the same alarm system unit that has 2 inputs and 5 outputs PGM Task NO3 Configuring the system so that the intrusion to enterprise A premises is reported to the janitor NO3 and enterprise A employee NO4 by SMS messages and calls Enterprise A employee NO4 wants to receive a call only in the case if the janitor NO3 does not answer the call is out of network coverage or at that time the janitor s telephone line is engaged Director A NO1 Enterprise A Enterprise B Director B NO2 Worker A NO4 Worker B NO5 3 9 09 Alarm Janitor SMS Cails NO3 As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the first successful d
47. ssage only and does not want to receive any calls the director of enterprise B NO2 wants to receive a call and does not want to receive any SMS messages Director A NO1 Enterprise A Enterprise B Director B NO2 Worker A NO4 Worker B NO5 Janitor NO3 As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS message it is necessary to remove the users that should not receive any alarm messages Besides as per factory default settings calling feature in the case of alarm is also enabled for all users therefore call function must be disabled for all users except user NO2 a First of all alarm system unit must be programmed in the way so that when security is armed in office A output PGM1 is turned on and when security is armed in office B output PGM2 is turned on b Output PGM1 is connected to ESIM252 input Z1 and output PGM2 is connected to ESIM252 input Z2 output PGM2 type should be high level c The following two configuration SMS messages must be sent to Esim252 system XXXX SMSEXTRA Z1 SC2345 CC12345 where SC2345 means that alarm SMS message sending to users NO2 NOS is disabled after input Z1 is violated CC12345 means that alarm calls are disabled for all users NO1 NOS5 after input Z1 is violated XXXX SMSEXTRA Z2 SC12345 CC1345 where SC12345 means that alar
48. t control by call value can be COC1 C1 output or COC2 C2 output ValueN structure is CnVal when Cn is command name 2 letters This does not apply to MS and CT commands When requesting MS and CT parameters MS and CT must be followed by one character user number 1 2 3 4 or 5 E g XXXX_SMSEXTRA COC1 CE CS MS1 MS3 3 9 2 2 Settings of the output controlled by SMS messages This chapter describes the ways of informing users when they are trying to open close the relay output s via SMS messages des cribed in chapter 3 6 Parameters are changed by sending the following SMS message to system ESIM252 XXXX_SMSEXTRA 0CSx Valuel Value2 ValueN XXXX user password OCSx output control by SMS value can be OCS1 C1 output or OCS2 C2 output Value structure is CnVal where Cn is command name 2 letters and Val its value digits without spaces or punctuation marks 28 FOR ADVANCED USERS All these features can be configured using program ELDES Configuration Tool Value CnVal table of values Val possible a Cn command n Initial factory command Command description Comments name 2 letters e default values meaning CB1 means that when users control the cB 1 Confirmation call mode output via SMS message they are notified A is enabled for all users about a successful output status change Enabling A Serie by a confirmation call disabling connemation call
49. that call To differentiate whether the output was turned on confirmation call will be set to ring for 3 seconds and the confirmation call will ring for 10 seconds when the output was turned off a First of all ESIM252 system output C1 has to be connected to the connectors of heating controller unit b The following configuration SMS message must be sent to Esim252 system XXXX_SMSEXTRA COC1 CE1 CS1 CT113 CT1010 MS12 where COC1 means C1 output control by call is enabled for users NO1 CS1 means that confirmation call feature is enabled for user NO1 after output C1 status changes CT113 means that user NO1 will receive a confirmation call when the output is turned on and call duration is 3 seconds CT1010 means that user NO1 will receive a confirmation call when the output is turned off and call duration is 10 seconds MS12 means that Toggle mode is activated for user NO1 which means that output status is changed with every call 20 A FOR ADVANCED USERS All these features can be configured using program ELDES Configuration Tool Task No2 Configuring the system so that users NO1 and NO2 receive SMS message about a burst water pipe flood at home SMS mes sages must be delivered to both users User NO1 oa Heating Controller User NO2 r OS pire ON e As per factory default settings SMS message sending feature in the case of alarm is enabled for all users
50. tion is gt 600ms GSM Control System AC DC RELAY1 ESIM252 RELAY2 COM Z5 Z4 Z3 Z2 Z1 aa E AUX AUX Alarm system or other appliance Picture 2 SINSd twd EN9d ZW9d 19d HIGH LEVEL AC DC Metal box PE contact Fuse 500 mA 10 24V O 230V 50Hz O Picture3 AC power supply connection circuit 1 6 System Installation The system can be installed only in a metal or non flammable plastic enclosure If the metal enclosure and transformer is used it is necessary to ground the enclosure using yellow green colour cable For the connection of 230V transformer use 3x0 75 mm 1 thread double isolated cable The primary circuit of the transformer must be connected through 0 5A fuse 230V power supply cables cannot be grouped with low voltage cable group For the connection of power supply and output connectors use 1 thread 2x0 75 mm cable For the connection of input output connectors use 0 50 mm 1 thread cable 1 Fasten the system in the box using fastening holders 2 Place SIM card in the holder but make sure that SIM card PIN code is disabled PIN code can be disabled by putting SIM card into mobile phone and following proper menus SIM card should not have any remaining SMS messages 3 Connect the circuit as shown in fig No 2 Power supply cables are connected last When connecting Esim252 to alarm system pow
51. ts operation and installation It is very important to read User Manual before start using the system A quick start guide is located in first two chapters Chapter 3 and 4 describe additional system capa bilities CONTENT General Information dell 1 2 es 1 4 S 1 6 Function Operation Description Technical Specifications Connector Functionality Connection Circuit System Installation System Pre operation and the Main Control Commands 2 1 2 2 23 2 4 Selecting device language and verification of SMS central number Password Change User Numbers 2 3 1 Saving or Changing Numbers 2 3 2 Verification of Saved Numbers 2 3 3 Deletion of Saved Numbers a Dat andino as toas 9 Additional System Capabilities 3 1 32 3 3 3 4 35 3 6 3 7 3 8 3 9 Renaming Zones and Controlled OUtpUt essscccssssseeeceeeseeee 10 Enabling Disabling Zones Info on Status SMS Blocking Unknown Numbers Remote Microphone Listening Managing C1 and C2 Controlled Outputs Timer SMS Message Delivery to Multiple Users Calling ale o Configuration for advanced users 3 9 1 Additional possibilities of configuring zones inputs alarm and restOre ssssesssssssrssssssssssssssssssse 25 Additional possibilities of controlling and configuring controller C1 relay output 3 9 2 1 Settings of the output controlled by calls 3 9 2 2 Settings of the output controlled Dy SMS message Sian earar a
52. until the first successful delivery of the SMS message and calling in the case of alarm is enabled for all users until the first answered call calling feature in the case of alarm must be disabled for users NO1 and NO2 Mandatory SMS delivery to all users must also be enabled a First of all a flood sensor is connected to Esim252 input Z1 b The following configuration SMS messages must be sent to Esim252 system XXXX_SMSALL ON where SMSALL enables mandatory SMS message delivery feature for all users XXXX SMSEXTRA Z1 CC12 where CC12 means that alarm call feature is disabled for users NO1 NO2 after input Z1 violation We make an assumption that users NO3 NO5 were not preset in the system at all USER MANUAL ELDES ESIM252 V1 0 21 i FOR ADVANCED USERS All these features can be configured using program ELDES Configuration Tool E g 4 The company taking care of automatic systems needs to have information about critical breakdowns of mechanisms and has to quickly react and eliminate the breakdown There are three members of operating personnel NO1 NO2 and NO3 Task No1 Configuring the system so that operating personnel member NO1 receives SMS message about the breakdown of gas boiler Working normally a gas boiler transfers a signal and when it breaks down the signal is not transmitted Lt D 5 Worker Gas boiler F NO1 E gt 7G eo NO2 mos system NO3