Maintenance Instructions SA931
Contents
1. 45 5 A931 BA931e Version 6 1a 04 2001 Installation User and Maintenance Manual SIUS AG Im Langhag 1 CH 8307 Effretikon Switzerland Tel 0041 523439191 Fax 0041 52 3431214 BA931e Version 6 1a SIUS AG cm 04 2001 General l I Warranty Conditions Dear customer we are pleased that you have chosen a product of SIUS Ascor and we wish you enjoy it If your product should have any defect during the time of warranty please contact your national SIUS dealer Your Warranty With this warranty SIUS grants that this product has from the time it has been bought no material or processing error for 1 one year If during the warranty time the device manifests any defect based upon a material or processing error SIUS respectively the national dealer will under the above described conditions without billing the material or work repair it or if SIUS evaluates it replace parts or all of it SIUS keeps the right of if we evaluate so replacing spare parts with as new spare parts or replacement spare parts but also to exchange low cost products with new respectively replacement products Conditions 1 Warranty services are only made if the defect product is handed out together with the original sales receipt with indication of purchase date product type and name of the sales representative SIUS keeps the right of rejecting warranty services if the sales receipt is not complete not filled out
2. 7 2 2 Distributor MD931 and remote control RC931 The distributor MD931 is connected to the CU931 with the cable KVO14 L L length please determine when ordering The CU931 socket for this is shown in chapter 1 2 pos 20 and 21 Monitor M931 shot sensor and remote control RC931can be connected directly onto the distributor MD931 Distributor MD931 1 Socket to connect CU931 2 Socket to connect remote control RC931 3 Socket to connect monitor M931 4 Socket to connect for shot sensor Remote control RC931 1 ZOOM to select the next zoom level ENTER If the menu is activated enter selects the inverse displayed function MENU The first validation activates the menu which is displayed on the monitor ZOOM The menu has four functions Clear display ENTER print screencopy print recordsheet and exit the menu Every next validation makes the cursor MENU jump to the next function MATCH If sighters sighting shots are shot the match function makes the shooting pro gram change to match As long as no shot has been fired in the match mode the shooter has the possibility to return to sighters mode by pressing match BA931e Version 6 1a 64 SIUS AG cm 04 2001 Accessories 7 3 7 3 Specialities for Rapid Fire Every shooter in Rapid Fire disciplines uses 5 targets which are called a bay The RFP25 target system consist of 5 25 50 LON targets equipped with red green sig
3. When you are in the default menu press sift access the disciplines menu BA931e Version 6 1a u 27 SIUS AG cm 04 2001 The disciplines menu 4 2 4 2 The Disciplines Menu In this menu all the disciplines are displayed of the chosen range type see Options RngT chapter 4 3 All the displayed disciplines can be chosen by pressing the corresponding functionkey to 5 In our example the range type is 50m which has 4 disciplines only Eee ES sigh troh 3xzH E 4 tph The cursor stays on the active discipline in our example Ek40 The chosen firing mode is displayed in the upper right corner in our example sighters After the discipline is selected the submenu with the choice of the firing mode appears 4 2 1 Firing Modes Sigh Sighting shots Stg1 2 3 Stage 1 2 3 Qual Qualification Pron Prone Finl Final Stnd Standing Comp Competition Knee Kneeling Prec Precision Stage RapF Rapid Stage Score in tenth division evaluation For pistol disciplines with precision and rapid fire stage Centre Fire Pistol Sport Pistol both kinds of sighting shots can be chosen Center Fire Piztal Sigh Prec Sigh Rapt Finl The corresponding stage is right to Sigh sighters F1 Sighters in precision stage F3 Sighters in rapid fire stage F2 and F4 are the assessed competition stages F5 is the final stage With the button you return to the previous menu Disciplines without c
4. The main free shooting program menu is made of three windows you can move to the next one by pressing Fs iH 9 SED Free HPis oom Hrd Roll Lir Li AE ED FreezhFiz BiB H BD FreezhFiz Saal ar arl PE Be sigh Sing Heti Rell You can return to the main program default menu by pressing twice to get to the options menu Press for range type and select the discipline and the firing mode you want 4 5 2 Main menu of free shooting programs The main free shooting program menu is very similar to the main shooting pro gram menu 14 9 50 doom Heed Rel F1 Zoom Zoom level F2 HrdC Hardcopy Prints out what the monitor displays F3 Rcall Recall function doesn t display the value of the fired shots until you press Rcall F4 Clr Clear clears the shots displayed on the monitor F5 gt gt Next window leads to the next window in the main free shooting program menu ee BA931e Version 6 1a 48 SIUS AG cm 04 2001 Free Shooting Programs 4 5 4 5 3 Firing modes for the free shooting programs Firing modes for free shooting programs F1 Sigh Sighter sighting shots are displayed on the monitor but no total is calculated for them Sighters can only be activated after the start or after a total but not during a counting shot group F2 Sngl Single shot shots are displayed as soon as detected F3 DefD Defered display shots are displayed as soon as you press Rcall F4 Rcll Recall displays the
5. are displayed 4 3 5 Lng Language in the options menu In this submenu you can chose the language for the control unit and monitor display Sprache ENG GER ITA FRA F1 ENG English F2 GER German F3 ITA Italian F4 FRA French After pressing F1 F4 the language of what is displayed on the control unit and on the monitor changes into the chosen language Some terms remain in English even if an other language is chosen so that International competitions aren t disturbed BA931e Version 6 1a 34 SIUS AG cm 04 2001 Maintenance Menu 4 4 4 4 Maintenance menu In the maintenance menu are all the tests and service functions F1 Test F2 Serv F3 Set F4 Net F5 Feed Targ Tests to check the system Service functions Settings Network configuration Manual rubber or paper tape feed 4 4 1 Test menu in Maintenance menu In this menu are test functions to test the system F1 Targ F2 Line F3 Self Target test Line test Self test BA931e Version 6 1a 35 SIUS AG cm 04 2001 Maintenance Menu 4 4 4 4 1 1 Targ target test in test menu For the target test the printer has to be turned on because the result is not displayed but printed only Test Functionz larg Het Selt After pressing the connected target or detection system is tested and the result is printed Testing Targets HIC OO0D0 TIC OD001 PiteQ004 4 MI X DOD Input 0000 Cnt Freq 0000 LON ik
6. s 61e BY 01 S221 9u1 P UUOD O yLOLJ 9 qe Ajddns 190g pue e ep u16ue ejqe 24 020 0 99e d sj83100us epis 195Je1 e qe uonpbeuuo OL 6 9 YUSPFA UoneulugJe3 snq NOT S AGIA Xoq uonnquisiq p ECOLE 9 Q8 SpfH E 231004329 9 Jobe Z siubi jeubis Udas6 pad UM OL xeu NO1 0S SZS 19064e1 51u04329 3 WeDsp snis NM L L a a Y s 5 H e for e s I v v K K L LP ee T Yd E S Va mom Vi Qa mom 6 Q uu uui oat er er er Y DSP SNIS N N YODS SNIS YODSP SNIS NX T YODSH SNIS N z z 4 z zO 0L 9 SIUS AG cm 04 2001 20 BA931e Version 6 1a Installation 2 1 2 1 4 Installation of a 300 Meter System On a 300m firing lane the Connection cable target side shooters place pos 6 in the drawing has only 2 poles only data no Power supply The targets are electrically supplied by an additional power supply box 1 Electronic target 300 LON 1 max 10 6 Connection cable target side shooters 2 Target electronic place KV021 cable length 3 RJ45 cable aa023 data bus 4 Distribution box VJ45Y 7 Power supply box NT931 10 for max 5 Termination
7. cm 04 2001 How To Exchange Devices Of The Network 5 1 5 1 Exchange a CU931 Control Unit Do it like this 1 Disconnect all plugs reaching the CU931 2 Exchange the CU931 3 Connect all plug you disconnected before 4 Ifthe monitor displays Please enter the lane number after the booting you have a unconfigured control unit and can proceed with point number 9 Please enter the lane number 5 f your control unit was once configured you have to reconfigure it For this press three times an to access the maintenance menu 6 Press ra Net Now the monitor displays the following menu You have entered the Hetwork Lonf mode fire you sure you want to reconfigure the network 7 Press Yes Now the monitor displays the following menu Which device do vou want to configure 8 Press Ctrl unit Now the monitor displays the following menu BA931e Version 6 1a 53 SIUS AG cm 04 2001 How To Exchange Devices Of The Network 5 2 9 Please enter the lane number for this use the number keys lee Ins By pressing r1 you can delete the last digit 10 Confirm the entry with ener Attention NEVER exchange more than ONE CU931 at a time 5 2 Exchange a target Do it like this 1 On the control unit where you want to exchange the target go into the maintenance menu for this press three times s 2 Press Net Now the monitor displays the following menu You have ent
8. makes it a lot easier to put them up in the same order If for example target number 2 is exchanged with target number 3 the Control unit number 2 receives all data shot on lane number 3 and Control unit on number 3 receives all data shot on lane 2 BA931e Version 6 1a 24 SIUS AG cm 04 2001 How To Use The Control Unit CU931 4 0 4 How to use the control unit CU931 4 0 Generalities 4 0 1 The keyboard With this key a selection is cancelled or you move to the next upper menu without choosing any function or menu If a window provides a help text it can be shown by pressing this key Next Activates the next menu Commands and choices from the active menu can be chosen by pressing the corresponding functionkey I a o 2 o Opt Customer specific functions Enter Confirms a choice And activates the next window SIUS ASR 3 SIUS 1 Keys with constant function 2 Number block cursor and figure functions 3 Softkeys BA931e Version 6 1a 25 SIUS AG cm 04 2001 How To Use The Control Unit CU931 4 0 4 0 2 Menu Control The Next Window button leads through the main menu Each confirmation activates the following menu Where appropriate each menu has submenus which can be activated by the corresponding functionkey All submenus ar
9. off during shooting sessions 4 3 3 Sens Shot Sensor in the options menu In this submenu you can turn on or off the shot sensor Shot Sensor EH OFF F1 ON The shot sensor is turned on F2 OFF The shot sensor is turned off If the shot sensor is connected and enabled cross shots are detected and displayed on the monitor see hidden miss chapter 4 4 3 1 and cross shoot chapter 4 6 1 BA931e Version 6 1a 31 SIUS AG cm 04 2001 The Optionen Menu 4 3 4 3 4 RngT Range Type in the options menu Iin this submenu you can chose the range type The cursor stays on the active range type in our example 10m It s also displayed in the upper right corner Range Tepe ili om F1 10m All disciplines which are shot on a 10 meter range F2 25m All disciplines which are shot on a 25 meter range F3 50m All disciplines which are shot on a 50 meter range F4 300m All disciplines which are shot on a 300 meter range F5 DIV customer specific specialities Each range type has one or more submenus The corresponding disciplines are described in chapter 4 3 4 1 4 3 4 4 Under F5 divers are the customer specific specialities they are not described furthermore 4 3 4 1 Range type 10m After you have chosen the range type 10m the following menu is displayed Range type Lem lon iB8mR Pent Biat Fr F1 10m 10m air weapon disciplines F2 10mR Running target 10m disciplines F3 Pent Pentathlon disciplines F4 Biat Bia
10. 1 Sets Devices and Targets 1 4 1 4 The Small Bore Rifle and Pistol Target Set 25 50 LON 25 50 LON e e 9 e 5 x 25 50 with red green signal lights mounted on target holder MSH25 BA931e Version 6 1a 14 SIUS AG cm 04 2001 Sets Devices And Targets 1 4 1 5 The 300 Meter Target Set S300 LON 1 6 10 Meter Running Target Set RT10 LON in preparation BA931e Version 6 1a 15 SIUS AG cm 04 2001 Installation 2 1 2 Installation The basic installation of a SA931 system is the same for all the disciplines and distances All data bus and power supply cables with exception of the connection cable target side shooters place are commercial twisted pair cables RJ45 For the connection cable target side shooters place the cables KV020 up to 100m and KV021 for more than 100m are used cable length The KV020 cable is a 4 pole cable with two poles for the data and two for the power supply This why only one power supply box is needed to supply the devices of the target side and the shooters place The KV021 cable is a 2 pole cable with two poles for the data This why you need a second power supply box for the targets The cables KV020 and KV021 are connected to the distribution box of the first CU931 respectively the first target in the following way 1 cable KV020 KVO021 2 2 white white 3 3 brown black 4 green i 4 5 5 yellow 6 6 s
11. 1 only all the other devices on the same network are set automatically After the Time function has been chosen the following display is shown Hate and Time E1 83 2881 69 38 au The cursor is placed on the first digit of the date which is the day Please enter the actual date useing the number keys In our example 01032001 for the first March 2001 Now enter the actual time In our example 0930 for 9 30 am If you have made any mistake continue by pressing any number key When you have moved the twelve digits the cursor jumps back automaticaly to the first digit Now you set the right date and time Confirm the entry with ere BA931e Version 6 1a 42 SIUS AG cm 04 2001 Maintenance Menu 4 4 4 4 4 Net Network menu in Maintenance menu ATTENTION Please ensure that all devices are connected to the network pluged in and turned on As soon as you have pressed to enter the net work menu the following menu is displayed on the monitor not on the CU931 You have entered the Network Conf made fire you sure you want to reconfigure the network F1 Yes Confirm the reconfiguration of the network F2 No Cancel the reconfiguration of the network As soon as you have pressed n the following menu is displayed on the monitor Which device do vou want to configure Fi Target F2 Ctrl unit P Clear all n F1 Target reconfigure the target see chapter 4 4 4 1 F2 Ctrl unit reconfigure the contro
12. 22 SIUS AG cm 04 2001 First Use 3 1 Service pin of the targets electronic A en i LI F a e As soon as the lane is configured the control unit confirms it with a beep The LED of the target electronic now blinks in a 1 second interval The target and control unit are now configured in our example they make the lane number 1 The display changes now and shows a target picture Lane number and date are shown in the upper right corner see picture 3 The shot made for the configuration isn t displayed Lane number A brm m i BD ibaa oy i Ih i T BH e Configure the other lines of this network in the same way Don t forget configure always the most left unconfigured one Attention DON T configure first all the control units and then shoot on the targets the network WOULDN T be configured RIGHT ___ _ __ _ _ lt x__LLLL_ gt gt _ E e BA931e Version 6 1a 23 SIUS AG cm 04 2001 First Use 3 1 After the configuration please select the language you desire chapter 4 3 5 and choose a range type chapter 4 3 4 page 32 and a shooting program chapter 4 2 page 28 Now you can start your shooting Attention If you make a mistake while configuring the system delete the configuration of the whole network You can do this out from one control unit see chapter 4 4 4 3 If your system is mobile you should write the lane number on each device it
13. 30 4 3 1 2 IdRq Identification Request in the FiDa Menu 30 4 3 2 Demo in the Options Menu 31 4 3 3 Sens Shot Sensor in the Options Menu 31 4 3 4 RngT Range Type in the Options Menu 32 4 3 4 1 Range Type 10m 32 4 3 4 2 Range Type 25m 33 4 3 4 3 Range Type 50m 33 4 3 4 4 Range Type 300m 34 4 3 5 Lng Language in the Options Menu 34 4 4 Maintenance Menu 35 4 4 1 Test Menu in Maintenance Menu 35 4 4 1 1 Targ Target test in Test Menu 36 4 4 1 2 Net Test in Test Menu 37 4 4 1 3 Self Test in Test Menu 39 4 4 2 Serv Service Functions in Maintenance Menu 39 4 4 2 1 PrnS Print Sequence Function in Maintenance Menu 40 4 4 2 2 PrnL Print Log Function in Maintenance Menu 40 4 4 2 3 Stat Status Function in Maintenance Menu 41 4 4 2 4 Clog Clear Log Function in Maintenance Menu 41 4 4 3 Settings Menu Set in Maintenance Menu 41 4 4 3 1 HMss Hidden Miss Function in Set Menu 42 4 4 3 2 Time Function Set Time in Set Menu 42 4 4 4 Net Network Menu in Maintenance Menu 43 4 4 4 1 Target Target Settings in Net Menu 44 4 4 4 2 Ctrl Unit Control Unit Settings in Net Menu 44 4 4 4 3 Clear All Delete the Configurations of all Devices of theNetwork in Net Menu 45 4 4 5 Feed Manual Tape Feed in Maintenance Menu 46 4 5 Free Shooting Programs 47 4 5 1 How to Get to the Free Shooting Programs 47 4 5 2 Main Menu of Free Shooting Programs 48 4 5 3 Firing Modes for Free Shooting Programs 49 4 5 4 The Totals Menu for Free Shooting Programs
14. 49 BA931e Version 6 1a f SIUS AG cm 04 2001 Glossary IV 4 6 How the Screen is Displayed 50 4 6 1 Cross Shot Indication 51 4 6 2 Screen Saver 51 5 How to Exchange Devices of the Network 52 5 1 Exchange a CU931 Control Unit 53 5 2 Exchange a Target 54 6 Troubleshooting 56 6 1 General Troubleshooting 56 6 2 Exchange Fuses 59 6 2 1 General 59 6 2 2 Dimensions of the Fuses 59 7 Accessories 60 7 1 Printer D931 60 7 1 1 How to Exchange the Paper Tape Coil 61 7 1 2 PrinterTest 62 7 2 Remote Control 63 7 2 1 General 63 7 2 2 Distributor MD931 and Remote Control 64 7 3 Specialities for Rapid Fire 65 7 3 1 How to Set the Control Unit CU931 65 7 3 2 How to Set the Time Control Unit TCU931 65 7 3 3 Synchronisation of Several Time Control Units 67 7 4 Spectator s Monitor M14 68 7 5 Individual Score Boards 68 7 6 How to Connect a PC 69 8 Maintenance 70 8 1 General 70 8 1 1 Target Maintenance 70 8 1 2 Order Materials 70 BA931e Version 6 1a 8 SIUS AG cm 04 2001 Sets Devices and Targets 1 1 1 Sets Devices and Targets 1 1 Basic Installation For the basic installation you need a power supply a connection cable target side shooters place KV020 or KV021 and two LON bus terminations For every system you need 2 Terminators electrical resistance VJ45R of the LON Bus and at least 1 Power supply box NT931 2 for max 2 lines or NT931 10 for max 10 lines 1 Connection cable target side sho
15. 525 50 LON A Q S25 50 LON with signal lights g j RT10 LON CU931 with optional Printer D931 CU931 with M931 BA931e Version 6 1a aH SIUS AG cm 04 2001 Glossary IV Glossary I Warranty Conditions 2 Il Copyright 3 Ill Concept and Application Possibilities 4 IV Glossary 6 1 Sets Devices and Targets 9 1 1 Basic Installation Set 9 1 2 Shooting Range Set FP931 10 1 2 1 Assemble the Device Holder HST931 11 1 3 The Air Rifle and Air Pistol Target Set S10 LON 12 1 3 1 Assemble the Wall Mounted Target Holder WHS10 13 1 3 2 Assemble Target and Butt to the Wall Mounted Target Holder 13 1 4 The Small Bore Rifle and Pistol Target Set 25 50 LON 14 1 5 The 300 Meter Target Set S300 LON 15 1 6 Running Target 10 Meter Set RT10 LON 15 2 Installation 16 2 1 Basic Installation 17 2 1 1 Installation of a 10 Meter System 18 2 1 2 Installation of a 50 Meter System 19 2 1 3 Installation of a 25 Meter System 20 2 1 4 Installation of a 300 Meter System 21 3 Installation and First Use 22 3 1 Configuration of the Network 22 4 How to Use the Control Unit CU931 25 4 0 Generalities 25 4 01 The Keyboard 25 4 02 Menu Control 26 4 1 The Main Menu 27 BA931e Version 6 1a 6 SIUS AG cm 04 2001 Glossary IV 4 2 The Disciplines Menu 28 4 2 1 Firing Modes 28 4 3 The Options Menu opt 29 4 3 1 FiDa Firers data in the Options Menu 29 4 3 1 1 IdNo Identification Number in the FiDa Menu
16. 6000 P 0000 0000 D DOOD Statue DD Temp 1 00 vVera amp ion 1 la HIC Hardware Identification Code Hardware version of the target print TIC Target Identification Code Use codes up to now 0000 Target Print without target 0001 S10 LON 0002 S25 50 LON 0003 S25 LON 0004 S100 LON 0005 S300 LON 0006 Deltabar 100 LON 0007 Deltabar 128 LON 0008 S101 LON PIC PLD Programmable Logic Device Identification Code BA931e Version 6 1a 36 SIUS AG cm 04 2001 Maintenance Menu 4 4 MIX Mounting Index measurement disposition of the system 0000 miNormal normal 0003 miRot180 Shot axe inversed 0005 miFlipO Cover at the back 0007 miFlip180 Cover at the back and shot axe inversed Input not used Cnt Freq not used LON Clk not used P Q D Are the measurement distances They should be zero Status Status of the counter units Should be zero Temp Temperature measured in the target Version Software version of the target electronic 4 4 1 2 Line test in test menu For the line test the printer has to be turned on because the results of the test are printed and not displayed Test Functions Targ Het Selt After pressing the message PLEASE WAIT appears After the network is tested the result is printed BA931e Version 6 1a 37 SIUS AG cm 04 2001 Maintenance Menu 4 4 Not ovarvigw TG Conflicts TG Alone TG Total ooo ooo O00 ME Conflicts ME Al
17. 8 SIUS AG cm 04 2001 Installation 2 1 2 1 2 Installation of a 50 Meter System The only difference between the installation of a 10m and 50m system is the distribution boxes In outdoor systems 25m 50m 300m the distribution boxes are incorporated into the targets 1 2 1 2 1 2 1 2 M SUS ASCOR M SIUS ASCOR X SUS 4SCOR X SUS 4SCOR X 1 Electronic target 25 50 LON 1 max 10 Target electronic RJ45 cable aa023 Distribution box VJA5Y LON bus termination VJ45R Ui 3 UJ NF 6 Connection cable target side shooters place KV020 cable length data bus and Power supply 24V DC 7 Power supply box NT931 10 for max ten firing lanes respectively NT931 2 for max two firing lanes BA931e Version 6 1a 4 19 SIUS AG cm 04 2001 2 1 Installation 2 1 3 Installation of a 25 Meter System The installation of a 25m system is initially the same as the one of the 50m system the instead of the conventional The light signals are added as on the following scheme In target number 5 light signals distribution box VJ45LS 8 has to be distribution box VJ45Y GCNIL HUN 04100 OWI ASU A JO peaysul STSPFA Xoq uonnquasip syubi jeus seue Bul OM JO Z LEGLN AjoAnedseJ soue Huy Ud Xew JO OL LEG LN Xoq Ajddns samod
18. ON bus termination VJ45R Connection cable target side shooters place KV021 0 cable length 7 Power supply box NT931 10 for max ten resp NT931 2 for max two firing lanes 8 PCor laptop 9 LONDONGLE 10 Data bus cable aa023 1 7 length 1 7m AunBWN On the PC or respectively on the laptop the software SiusData has to be installed SiusData captures the data and writes the results into an csv table ordered by the start numbers given in at the control units SiusData is not a ranking program but a basic data recording program With an Excel97 macro you can then import this csv file If you are familiar with Excel it s easy to create simple rank lists through sum fields and sorting Printing through the formula generator is also possible It s possible to use other spread sheets software but you have to program the data import and export The program can also make graphical printouts of any shot shooting program by sending the data to the enclosed program SiusLane See our homepage at http wwwsius com for the newest information BA931e Version 6 1a 69 SIUS AG cm 04 2001 Maintenance 8 8 Maintenance 8 1 General Every SIUS system in impeccable technical condition assures a precise detection of every shot and also the correct scoring of them at anytime Please pay the necessary attention to this chapter 8 1 1 Ta
19. c 14 RS232 port Contrast control 15 Video signal socket for the monitor VGA 9 Brightness control 16 Service buttons top MODE bottom SEVICE 10 Mains voltage pilot lamp 17 Peripherals socket ex Individual Score Board 11 Main switch 18 Power supply socket 24 26 Vdc 12 Printer port Centronics 19 RJ 45 socket network 13 KV014 cable socket to connect 20 Remote control and running target control unit port Distributor MD931 see page 63 21 Remote control and running target control unit port BA931e Version 6 1a 10 SIUS AG cm 04 2001 Sets Devices and Targets 1 2 1 2 1 Assemble the Device Holder HST931 A II S 11 8 E us NN AL 8 11 12117 16 27114272 a 3 CU931 3 CU931 105 3 D931 3 D931 pos Designation art no Amount 1 Monitor plate of HST931 HST931A002 1 2 Angled holder of HST931 HST931A001 1 3 Small side plates only CU931 HST931A003 2 3 Big side plates CU931 D931 HST931A004 2 4 Lock plate HST931A005 1 5 Star shaped knob M5 ama58 1 6 Knurled nut M4 amar004 1 7 Self locking hexagon nut M6 amms06 2 8 Hexagon socket screw M6x16 lams6 06x16 2 9 Raised oval screw M3x6 amsl03x06 6 10 Flat washer amu011 1 11 Flat washer amu021 4 12 Flat washer amup005 2 If you use the device holder HST931 to assemble only the monitor to the contr
20. d by the first channel Master of the first time control unit TCU25 If one bay a set of five targets has to be used separately just turn the switch pos 7 of the corresponding TCU25 on position INTERN Now this channel can be programmed differently than the other still synchronised time control units BA931e Version 6 1a 67 SIUS AG cm 04 2001 Accessories 7 4 7 4 Spectator s monitor M14 14 As spectator s monitor you can use our spectator s monitor 14 or the 9 Monitor the shooter s monitor M931 or any other VGA monitor for the connection see chapter 1 2 pos 15 7 5 Individual score boards ARA coz L iog Ns LET BT EE Magai T 22 253 NR NAME 385 N STURNY SUI 071 T SAMAF USA On the left side Individual score board AZTO3 for all 10 50 and 300 meter disciplines On the right side Individual score board AZT04 for all 25 meter disciplines For both individual score board types an additional LED table which can display the start number the name and the nationality of the shooter is available BA931e Version 6 1a 68 SIUS AG cm 04 2001 Accessories 7 6 7 6 Connection to a PC To integrate a PC or a laptop for the data capture and rank list production is very easy You only need to plug a LONDONGLE to the parallel port LPT printer port of your PC or laptop Electronic target Target electronic Data bus cable aa623 1 7 Distribution box VJ45Y L
21. e circle represents the diameter of the projectile depending on the zoom stage AUNA 5 Ifyou are shooting sighters sighting shots the upper right corner of the target is shown reverse 6 Lane number date and time are displayed here see chapter 2 2 1 7 Header of the results table No Shot number Val Shot value in complete rings and tenth division of rings 8 Results table last ten shots Inner ten s are show with an asterisk see shot number 3 Frame hits are shown with l see shot number 1 BA931e Version 6 1a 50 SIUS AG cm 04 2001 How The Screen Is Displayed 4 6 9 Current shooting program 10 Totals and MPI MPI mean point of impact of the last group of shots deviation in mm from the centre of the target Totals 1st total total of the current group of 10 shots 2nd total total of the current shooting program 11 Last shot the result is the large number 12 Status field Ready system is ready Stop system is not ready OFFLINE no connection to the target Demo demonstration mode is switched on 4 6 1 Cross shot indication If you use a shot sensor the system does detect shots fired from a different lane cross shot Cross shots are displayed with this symbol This symbol is displayed just under the results table if the system detects a cross shot The cross shot symbol remains displayed for approximately 7 5 minutes then disappears automatically if no other cross shot
22. e explained hereafter 4 1 The main menu 3xd4B Sigh Mest HSS ES trao eA E 4 3 The options menu Window SWORTTION Filla Demo Sens Rngt Lng LSE LLLAL L LLLILLALLLLA i4OLILZLZZLALZZEUESSR BA931e Version 6 1a 26 SIUS AG cm 04 2001 The Main Menu 4 1 4 1 The Main Menu SIBI de Boom Hed Cle The start respectively the default menu comes up after booting 25 seconds after turning on the control unit or after some seconds without activity Displayed in the top right corner is the currently set discipline 3x40 shots and the firing mode Sighters During the shooting the shot number 10 and the value of the last shot 9 and in tenth division of a ring 90 are shown on the upper left corner of the display 1 9 490 Boom Hed Cle Functions F1 Zoom Zoom level F2 HrdC Hardcopy Prints out what the monitor displays F3 Clr Clear Clears the shots display of the monitor F4 Next Changes the presentation of the last shot into a cross This is used in finals and for disciplines where the last shot can cover other shots if your using the biggest zoom level F5 Tot Total Terminates the shooting program calculates shows and prints the total Attention Make the total at the end of the shooting practice so that the begun program stops Otherwise all shots appear again when you start the system the next time All shots stay in the memory of the CU931 E
23. ered the Network Conf made fire vou sure vou want to reconfigure the network 3 Press Yes Now the monitor displays the following menu Which device do vou want to configure Fi Target 2 Ctrl unit Fi Clear all 4 Press Target Now the monitor displays the following menu Please fire a shot at the target of this lane or press the service pin button on the target 5 Plug off the corresponding target without interrupting the network trunk see picture on page 52 6 Exchange the target 7 Plug in the LON bus BA931e Version 6 1a 54 SIUS AG cm 04 2001 How To Exchange Devices Of The Network 5 1 8 Open the target 9 Please fire a shot at the target of this lane or press the service pin on the target SO ee px DE 2 Hs 10 Close the target 11 If the monitor displays ERROR No feed on target press escape then press to make this message diapear Attention Never exchange more than one target at the time BA931e Version 6 1a 55 SIUS AG cm 04 2001 Troubleshooting 6 1 6 Troubleshooting 6 1 General troubleshooting To reset the settings of the CU931 back to factory settings Turn off disconnect the power supply so as no device of the shooters place is under current Plug in again and while Bootstrap loader is displayed on the LCD of the CU931 press the mode button see chapter 1 2 pos 16 on page 10 until the message please release the coldstart butt
24. ersion The other information are for SIUS technicians 4 4 2 4 Clog Clear Log function in Maintenance menu Clear log Clears the entire log memory of the CU931 Seruice Functionz PenS PrnL Stat Clog Attention This is irrevocable 4 4 3 Settings menu set in Maintenance menu In the settings menu you can change the date the time and de activate the hidden miss function HMss The cursor remains on the last activated setting in our example HMss With the buttons and 4 the cursor position can be moved The state of the setting which is marked with the cursor is displayed in the upper right orner in our example for HMss F1 HMss Hidden miss ON OFF see chapter 4 4 3 1 F2 Time To set the time and the date see chapter 4 4 3 2 BA931e Version 6 1a 41 SIUS AG cm 04 2001 Maintenance Menu 4 4 4 4 3 1 HMss hidden miss function in set menu In the HMss submenu you can set the hidden miss function ON or OFF You can use his function only if your using a shot sensor Hidden Miss ay F i e F1 ON To set the hidden miss function ON F1 OFF To set the hidden miss function OFF If the HMss function is set on a shot that hits the target but who wasn t detected by the shot sensor is put in the log memory but isn t counted as a zero 4 4 3 2 Time function set time in set menu With the time function you can set the actual time and date The time setting has do be done on one CU93
25. eruice Functionz Pens Peni Stat LLag F1 PrnS Print screen Makes a printout of what is displayed on the monitor see chapter 4 4 2 1 F2 PrnL Print log Prints out the memory of the CU931 see chapter 4 4 2 2 F3 Stat Prints out the status of the system see chapter 4 4 2 3 F5 CLog Clear log Clears the log memory of the CU931 which is irrevocable see chapter 4 4 2 4 BA931e Version 6 1a 39 SIUS AG cm 04 2001 Maintenance Menu 4 4 4 4 2 1 PrnS Print Sequence function in Maintenance menu not available for sighting shots a 2 e e PrnS prints out the graphical representation of the last 20 shots and makes a copy of the last shooting program printout with the remark C for Copy A1f RIFLE 40 SHoOT amp CANE many BA DEORI EH ML e s Tox 5 i cmm Air Rifle 4D Show Qualification lon Py os Rie oe oe den C for Copy 4 4 2 2 PrnL Print log function in Maintenance menu With PrnL the printout of the log memory is made Seruice Functions Penh Feel Stat Chog This function is made for SIUS technicians only el BA931e Version 6 1a 40 SIUS AG cm 04 2001 Maintenance Menu 4 4 4 4 2 3 Stat Status function in Maintenance menu With Stat the printout of the of the system status is made Seruice Functionz Pens Peni Stet RE World Cup M92 WC V6 1a software version PLD VR 5 17 PLD version PLD Programmable Logic Device of the CU931 LON VR 1 1a LON v
26. hield shield 7 plug for LON bus cable aa203 If the shooting range of your system is under 100m a power supply box NT931 10 is connected on the distribution box VJ45Y where the connection cable target side shooters place KV020 is fixed For a system with maximum 2 shooting lines you can use a power supply box NT931 2 Plug in the hollow plug directly into the the power supply socket of a CU931 see pos 18 in chapter 1 2 page 10 If the shooting range of your system is over 100m a second power supply box has to be put on the target side It has to be connected on the distribution box VJ45Y where the connection cable target side shooters place KV021 is fixed The connection of the single devices is made by aa203 cables Just plug them into the corresponding distribution box Each LON bus has to be terminated on the last target and the last control unit with a LON bus termination VJ45R BA931e Version 6 1a 16 SIUS AG cm 04 2001 Installation 2 1 Outdoor Systems 25m 50m 300m have the distribution boxes integrated into the target as as they are protected from weather ionfluences For safety and current distribution reasons only 10 lines can be connected on one network If you have more than 10 lines a second network has to be installed You can link them with a router if you want to include a measurement PC or any other device which has to be connected with the whole network 2 1 Basic Installation Mou
27. hoosing any shooting program BA931e Version 6 1a 28 SIUS AG cm 04 2001 The Options Menu 4 3 4 3 The Options Menu opt In this menu additional functions and setting can be made The cursor stays on the last used option With the button gt 9 and you can move the cursor In the upper right corner the settings of the function is displayed With the functionkeys F1 F5 you chose the function EPTO Fila emo 5 F1 FiDa Firers Data menu F2 Demo Demonstration mode F3 Sens Shot sensor F4 Rngt Range Typ F5 Lng Language 4 3 1 FiDa Firers Data in the Options Menu In the upper left corner the name of the submenu and in the upper right corner the settings of the function on which the cursor stays is displayed Firerz Hata idia ides F1 IdNo Enter a shooter identification number F2 IdRq Identification number request on off With the button you can return to the previous menu without choosing any Ifunction BA931e Version 6 1a 29 SIUS AG cm 04 2001 The Optionen Menu 4 3 4 3 1 1 IdNo Identification Number in the FiDa menu With this function you can enter a shooter identification number maximum 9 digits For this use the numbers keyboard ld lumber iz3455T783 DEL SERIT F4 DEL Delete delete the last digit F5 EXIT Exit Exit the menu without changes Confirm the right input with Enter ener 4 3 1 2 IdRq Id number Request in the FiDa menu In this submenu you can tu
28. inter has no paper or if the locking lever is in the zi D931 F 99 m open position N 3 Keys SEL Selection switch off for 3 1 2 paper feed LineFeed Has to be on for printing LF Line feed only possible if selection is off BA931e Version 6 1a 60 SIUS AG cm 04 2001 Accessories 7 1 7 1 1 Exchange of the paper roll article number aag048 1 Hold the cover at the back and lift it 2 Switch the looking lever back up 3 Press the roll holders outwards and remove the paper roll D 4 Place new paper roll as illustrated 6 Pull paper forward and align it on picture 7 Switch the looking lever into front position Use only original paper 5 Introduce the paper until it comes out on the other side 10 Switch off selection SEL key Selection is desactivated when select light is off 11 Press LineFeed key and check paper feed 12 Switch selection on again 8 Guide paper through the slot of the cover 9 Place the cover into the front stop and push it down until it engages BA931e Version 6 1a 61 SIUS AG cm 04 2001 Accessories 7 1 7 1 2 Printer test For a test printout switch the printer off pos 13 on previous picture hold down the SELECT and LineFeed key pos 10 and 11 on previous picture and while pressing turn the printer on again Two test printouts are now made A part of the top line may be missing All
29. l unit see chapter 4 4 4 2 F4 Clear all delete the network configuration of all devices of the network see chapter 4 4 4 3 With you can abort the network configuration menu without changing the network configuration BA931e Version 6 1a 43 SIUS AG cm 04 2001 Maintenance Menu 4 4 4 4 4 1 Target settings in Net work menu To configure the target press 5 The monitor displays now the following message Please fire a shot at the target of this lane or press the service pin button on the target If the target is unconfigured the LED blinks in a 1 second interval you can shoot on the target or press the target s service pin The successful configuration is confirmed by a beep of the control unit and the monitor displays the target again 4 4 4 2 Ctrl unit control unit settings in Net menu Attention Please make sure that all devices are connected to the network pluged in and turned on To configure the control unit press rz The monitor displays now the following message Please enter the lane number Please enter the lane number useing the number keys Es By pressing you can delete the last digit Having confirm the correct input with emer wait until the configuration is done BA931e Version 6 1a 44 SIUS AG cm 04 2001 Maintenance Menu 4 4 As soon as you have entred the lane number and confirmed with ened you are pleased to wait until the configurati
30. missing or unreadable 2 This warranty is not applicable for damage caused by change or adoption of the device without written authorisation of SIUS to make it correspond to an other country s national or regional technical or security regulations which is not the country for which it has been designed and made 3 This warranty is not applicable if the serial number or the type description of the product has been changed deleted removed or made unreadable 4 The warranty doesn t cover the following points a Regular maintenance and reparation or exchange of parts due to normal wear b Any changes or adaptation to use the product without written authorisation of SIUS for an other use than the one described in the manual BA931e Version 6 1a 22 SIUS AG cm 04 2001 General ii C Costs for the transport journeys of home services and all transportation risks which are directly or indirectly related to the warranty d Damage caused by the product due to 1 Uncalled for use inclusively a the use of the device for another purpose than the one described in the manual b the connection or the use of the device in a way which interferes with the national or regional technical or security regulations and c unsuitable or improper installed software 2 Reparations which were made by an service centre or an reseller who wasn t authorised by SIUS or reparations made by a customer 3 Accidents lightning water fire insufficien
31. nal lights and a time control unit TCU25 7 3 1 How to set the control unit CU25 For Olympic rapid fire where one shooter shoots on five targets one lane has to be set as master The shooting program is selected only on this master device which can be any of the five normally the most left or most right one If you select the Olympic rapid fire shooting program on one control unit this control unit is made automatically master The four other control units select automatically the same shooting program and are configured as slaves Each slave control unit displays the result shot on it s target on it s monitor and makes a printout if a printer D931 is connected on selection turned on The master control unit displays and prints out the all five shots and the total of them If during the green phase one or more targets don t receive a shot the corresponding control units display and print out a zero 7 3 2 How to set the time control unit TCU25 The TCU25 controls the signal lights used for two bays Hits are only computed if shot during a green phase if shot during a red phase the result is zero and the overtime is displayed and printed out for example OT 0 345 The long hole measurement which is made on turning targets is compensated with additional 0 2s The brightness of the red green signal lights can be regulated with the brightness control pos 1 and 3 on the next picture The switch Master ON OFF not t
32. nt the devices and targets as described in chapter 1 Now connect each device and target in accordance with the appropriate scheme which can be found in the chapter 2 1 1 to 2 1 4 Pay attention to the LON bus termination electrical resistance VJ45R The first use is described in chapter 3 How to connect the distribution box VJ45Y First divice second divice last divice sa 1 From to control unit target 4 To the next distribution box VJ45Y 2 Power supply box NT931 10 5 From the previous distribution box 3 Connection cable target side 6 Termination of the LON bus VJ34R shooters place KV020 or KV021 cable length BA931e Version 6 1a AZ SIUS AG cm 04 2001 Installation 2 1 2 1 1 Installation of a 10 Meter System EFE CU CU CU 931 931 3IEJESE HAE Hoce gAn izja izja DOE DESSE gAn Cc Este maaana GERAIS U 1 Electronic target S10 LON 6 Connection cable target side 1 max 10 shooters place KV020 cable length 2 Target electronic data and Power supply 3 RJ45 cable aa023 7 Power supply box NT931 10 for max ten 4 Distribution box VJ45Y firing lanes respectively NT931 2 5 LON bus termination VJ45R for max two firing lanes BA931e Version 6 1a 1
33. o confuse with master of the control unit CU931 enables the TCU25 to be synchronised with the other TCU25 If the program switch pos 4 is in position 0 you can chose between program menu 1 and 2 To choose program menu 1 press the start button once as a confirmation the button blinks once To choose program menu 2 press the start button twice as a confirmation the button blinks twice Any other position of the program switch is to select the shooting program depending if menu 1or 2 is active For example in menu 1 program number 6 is the RFP Olympic Rapid Fire Pistol green 8 seconds red 3 seconds BA931e Version 6 1a 65 SIUS AG cm 04 2001 Accessories 7 3 To start the program press the start stop button situated on the TCU25 pos 6 1 and 6 2 or press the external start button article number TCU25A501 The external start button is connected to the socket pos 5 1 and 5 2 As soon as the start button is pressed the red phase begins with the duration indicated on the table pos 8 The start button is blinking After the red phase the green phase starts in which all the hits are evaluated A red followed by a green phase is one round Programs with more than one round go through them automatically After the last green phase the blinking of the start button stops and a 20 seconds long red phase starts after which the signal lights turn off By pressing the start button a second time the program
34. of the LON bus VJ45R 10 firing lanes respectively NT931 2 for max two firing lanes BA931e Version 6 1a 21 SIUS AG cm 04 2001 First Use 3 1 3 First Use Because all the devices are connected to a network this network has to be configured Each control unit and target has to have the right line number so that each target transmits the data to the right control unit Once the configuration is made the system keeps it until you reconfigure it Also if the power is cut off 3 1 Configuration of the Network e Mount the system as described in chapter 2 1 e Plug in the power supply cable and turn on the monitors ATTENTION Before the configuration make sure that all devices of the network are turned on e Wait until the system has booted approx 1 min If the system is new and not configured shortly after the booting you are asked by a monitor message to set the lane number Please enter the lane number e Start the configuration always on the most left device Now enter the desired lane number by means of the number keys of the CU931 for example for the first lane and then confirm this with The display changes to picture 2 Please fire a shot at the target of this lane or press the service pin button on the target e Now shoot at the target of this lane in our example it s target number one or press the target s service pin see next picture on next page BA931e Version 6 1a
35. ol unit you can use the small side plates pos 3 If you want to mount the printer D9310nto the control unit you have to take the big side plates You can also put the locking system on the left side for this just reverse pos 4 5 and 10 Slide the holder over the control unit fit the holes to the threads and tighten the three screws M3x6 on both sides Assemble the monitor and control unit holder as shown above Tighten the hexagon socket screw in pos 8 together with the self locking hexagon nut In pos 7 Slide the monitor with it s plate into the fitting position and lock it with the angled holder by screwing in the knurled nut BA931e Version 6 1a 11 SIUS AG cm 04 2001 Sets Devices and Targets 1 3 1 3 The Air Rifle and Air Pistol target set S10 LON The Air Rifle and Air Pistol target S10 LON set consists of all parts needed to install one lane of a 10 meter range Which are 1 S10 LON Electronic target consistent of 5 S20A022 Target front mask ISSF Air Rifle 5 20A023 Target front mask ISSF Air Pistol 1 S20A037 Backing target 1 S20D001 Paper tape coil 35m 2 KFS20A005 Projectile spread protection 1 S20A019 Paper tape coil axe 2 aa203 1 7 Data bus cable 1 VJA45Y Distribution box for the data bus cables 1 WHS10 Wall mounted target holder plate 1 KA S10 Instruction sheet The Air Rifle and Pistol target S10 LON fron
36. on apears If the network configuration is mixed up Delete the network configuration of all devices connected to the network see chapter 4 4 4 3 and reconfigure all devices see chapter 3 1 Attention Configure always the leftmost unconfigured device If the monitor doesn t react anymore while configuring the network settings of a target Please ensure that all plugs and cables aren t damaged Check that the cables are connected corresponding to the installation scheme Check that the plugs are connected properly Configure the target as described in chapter 5 2 exchange a target If no shots are displayed on the monitor 1 If the status field on the monitor chapter 4 6 pos 12 on page 51 displays stop No shooting program has been loaded see chapter 4 2 Disciplines on page 28 2 If the status field on the monitor chapter 4 6 pos 12 on page 51 displays offline The target attributed to the control unit is not connected or wrong configured Please ensure that all Plugs and cables are intact Check that the cables are connected corresponding to the installation scheme Check that the plugs are connected properly If necessary configure the target as described in chapter 5 2 on page 54 exchange a target 3 Check that the target electronic print LME is pluged in correctly and mechanically fixed If the shots are displayed on the wrong monitor lane The network configuration is wrong Delete the network configura
37. on is done Please Hait The successful configuration is confirmed by a beep of the control unit and the monitor displays now the target again 4 4 4 3 Clear all in Net menu Delete the configurations of all devices of the network Attention Please make sure that all devices are connected to the network pluged in and turned on If you want to delete the configuration of all devices of the network press 4 The monitor displays now the following message Please Hait As soon as the message Please enter lane number appears the configurations of all devices of the network are removed Please enter the lane number Before you enter the lane number turn of all control units wait one minute and turn them on again After the booting all the devices are in configuration mode Configure the network as described in chapter 3 1 BA931e Version 6 1a 45 SIUS AG cm 04 2001 Maintenance Menu 4 4 4 4 5 Feed in the Maintenance menu This function makes a manual rubber or paper tape feed By pressing 5 Feed the target makes a manual rubber or paper tape feed The manual feed has the length of about 5cm for a S10 LON and 20mm for a S25 50 LON target The settings of the tape feed are factory settings During the shooting the feed is made automatically depending on the discipline The automatic feed is surveyed by the target and if it isn t made or not made correctly the monitor dis
38. one ME Total Total Routers Total XLon Total Others e Unconfiqurad TG Conflicts The amount of lanes which have more than one target assigned TG Alone The amount of targets which aren t assigned to any control unit TG Total The amount of targets which are connected to the network ME Conflicts The amount of lanes which have more than one control unit assigned ME Alone The amount of control units which aren t assigned to any target TG Total The amount of control units which are connected to the network Unconfigured The amount of devices which are unconfigured BA931e Version 6 1a 38 SIUS AG cm 04 2001 Maintenance Menu 4 4 4 4 1 3 Self test in test menu The self test checks the control unit CU931 Test Functions Targ Het Selt After pressing 5 if the printer is turned on the test printout is made which means all the printable symbols are printed out After this a separate window appeares on the monitor which allows you to test the keyboard of the CU931 Each key you press is displayed in this window so press every key of the keyboard and press to quit the keyboard test Now the display test of the CU931 starts all the segments are activated The display should be filled with 8s After a few seconds the display turns back to it s normal state or you can force this by pressing i 4 4 2 Serv Service functions in Maintenance menu In this menu are the service functions are in S
39. oters place KV020 or KV021 2 cable length in meters For shoot distances up to 100 meter the power supply for the targets is provided by a 4 pole connection cable target side shooters place KV020 cable length For shoot distances over 100 meter an additional power supply for the targets is needed This allows the use of a 2 pole Connection cable target side shooters place KV021 cable length BA931e Version 6 1a 9 SIUS AG cm 04 2001 Sets Devices and Targets 1 2 1 2 Shooting Range Set FP931 One shooting range set FP931 contains all the items which are used for the operation of one shooting lane 1 M931 VGA Monitor 9 1 CU931 Control unit SA931 HST931 Monitor holder for the mounting see chapter 1 2 1 aa203 1 7 Data bus cable length 1 7m VJ45Y Distribution box for the data LON bus cables KA FP931 Short description of the Shooting range set FP931 Additionally you need l N 1 88 Country specific power supply cable for the monitor nation code 101 GB 102 USA 110 Schuko 126 AUS For a voltage between 90 and 260 VAC the tension is regulated automatically Overview Contrast control and brightness control 12 13 14 15 16 17 1 Monitor M931 9 2 Control unit CU931 3 Connection for a barcode reader in preparation Device holder HST931 4 5 Locking system 18 19 20 21 6 Video cable 7 8 Monitor power cable 90 260 Va
40. plays ERROR No feed on target Press to remove this message BA931e Version 6 1a 46 SIUS AG cm 04 2001 Free Shooting Programs 4 5 4 5 Free shooting programs If free shooting program is selected you can combine sighting shots single shots and recall function to set up your own shooting program You can also generate subtotals intermediate totals and global totals Free shooting programs can be made for the following rang types 10m 50m 300m 4 5 1 HoW to get to the Free shooting programs When you are in the default menu press twice to access the options menu Then press to select the range type men Range Tune Lem a ihm ae Chose the desired range type with v 5 or F for example n for the 10m range type Now all the 10m range type disciplines are displayed Chose Free here with 5 to access the free shooting program menu Now you have the choice between rifle or pistol for rang type 300m there is obviously no choice here for example press ra for APis Range Tupe 18m lli Lime Pent Biat Free Hir Free Akit AFis E FreeAPis oom Hr dE Roll Lir i BA931e Version 6 1a 47 SIUS AG cm 04 2001 Free Shooting Programs 4 5 Now the free shooting program menu is active The default firing mode is sighters After about 25 seconds the display changes to show the main free shooting pro gram menu same as for the mainprogram to change into the default menu
41. plays all the time the cross shot sign see chapter 4 6 1 1 If a shot sensor is connected Across shot has been made the sign stays for 7 5 minutes If no cross shot has been made make sure that no objects are covering the shot sensor and check that the weapon is in right position to the shot sensor see specifications of the shot sensor 2 If no shot sensor is connected The shot sensor is turned on in the sens menu see chapter 4 3 3 on page 31 please turn it off e If on the printout or on the monitor the time or date is wrong Set the date and time with the time function see chapter 4 4 3 2 on page 42 BA931e Version 6 1a 57 SIUS AG cm 04 2001 Troubleshooting 6 1 e If the monitor loses the date after each booting turning on The battery of the control unit CU931 is empty Exchange the battery or send the control unit to the next service centre How to exchange the battery 1 Disconnect all plugs from the CU931 2 Open the device by pulling out the two Nylatch looking pins see picture The rear plate of the CU931 with all it s sockets and it s electronic print can now be taken out of the box Take care because the keyboard is still connected to the print with a flat band cable see picture 3 Turn over the box to have full access to the electronic print Take out the battery useing a small screwdriver Put in the new battery the plus pole is on the top Connect all the pl
42. rget maintenance In the leaflet for target maintenance which is delivered with every target you find every important information about target maintenance If you don t find your maintenance leaflet anymore you can download it at http www sius com order at your local agent or directly at SIUS AG 8 1 2 Order materials On the drawings in the maintenance guide the article designations and part numbers of every piece are noted Please address you orders to your local agent or directly to SIUS AG Im Langhag1 CH 8307 Effretikon Switzerland tel 41 52 343 91 91 fax 41 52 343 12 14 Internet http www sius com E mail adminGsius com BA931e Version 6 1a 70 SIUS AG cm 04 2001
43. rn on or off the Identification number request ld Humber required EH OFF F1 on You need an identification number to start a shooting program F2 off You don t need an identification number to start a shooting program With the button you can return to the previous menu without changing the settings of the IdRq If the shooter identification number request is turned on you have to type in the shooters identification number otherwise lane is blocked the status stays on STOP as long as no IdNr is enterd If you try to chose a new shooting program the following message appears Id Number Required please enter a shooters id BA931e Version 6 1a 30 SIUS AG cm 04 2001 The Optionen Menu 4 3 4 3 2 Demo in the options menu In this submenu you can turn on or off the demonstration mode The demo mode works only if a configured target is correctly connected to the control unit lemonztration Mode Or F F1 OFF The demonstration mode is turned off F2 ON The demonstration mode is turned on If the demonstration mode is turned on you can generate demo shots by pressing O the value of them are generated randomly If in the status window on the shooter monitor see pos 12 in chapter 3 3 demo is marked then the demonstartion mode is on On the printout the demo shoots are marked with an exclamation mark ATTENTION The demo mode is for demonstration purpose only Se it has to be turned
44. s an unbeatable value formoney and at the same time the best reliability All the known ISSF disciplines from 10 meter air weapons incl Running target up to 300 meter big bore rifles are pre programmed in one and the same device With the SA931 LON Automatic Electronic Precision Target Scoring System the following target systems are available e 10 meter Air Rifle and Air Pistol target Type S10 LON This target mounted with an force front frame and placed in a weather protected place can also be used with small bore weapons 50m disciplines 10 meter Running Target Type RT10 LON 50 meter Small Bore Rifle and Pistol target Type S50 LON 25 meter Rapid Fire Pistol Type S25m RFP LON Special Note The 25 and 50 meter system uses the same S50 target However red green signal lights used for timed firing of official Rapid Fire Pistol Matches have to be mounted on the S50 LON 25m RFP LON Targets o 300 meter Big Bore Rifle target Type 300 LON e The 50 100 meter Big Bore Pistol 9mm etc Target Type 100 LON and the ISSF DJF Hunting Target Type SKL LON are in preparation For the ease of use and easyer learning the system operations and the program structure and functioning incorporates the operation and functioning of the SA921 targetry System BA931e Version 6 1a 4 SIUS AG cm 04 2001 Concept and Application Possibilties I 10 LON 300 LON 1 ge m
45. shots when you are in DefD mode all shots since the last time you activated Rcall or since the beginning of the DefD mode F5 gt gt Next window leads to the next window in the main free shooting program menu 4 5 4 The totals menu for free shooting programs In this menu you can make different kind of totals uL E ah INE Free RFis Subi inti Toti F1 SubT Subtotal it s the total of the shot group All shots since the last subtotal respectively since the beginning of the shooting program are added together and a new shot group is generated F2 IntT Intermediate total makes a subtotal and a intermediate total from all shots since the start or the last intermediate total F3 Totl Global total makes a subtotal and a intermediate total the global total and terminates the shooting program F5 gt gt Next window leads to the next window in the main free shooting program menu BA931e Version 6 1a 49 SIUS AG cm 04 2001 How The Screen Is Displayed 4 6 4 6 How the screen is displayed An example of the 50m 3x40 shot shooting program after 10 shots 1234 5 67 8 So n ode dab do 2 e Hif de teal hors Bbghrterz F F L 9 10 N Target representation according to discipline and zoom stage Hit Representation of where a previous shot hit the target MPI Mean Point of Impact Last Shot representation of where the last shot hit the target Th
46. stops and the signal lights turn off To restart the program you have to wait for 3 seconds after which you can simply press the start button again 1 Brightness regulation of the red lights 2 Master On Off switch 3 Brightness regulation of the green lights 4 1Program switch of channel 1 5 1Socket for external start stop button 6 1Start stop button channel 1 7 1Intern slave switch of channel 1 8 Selectable programs 9 Command elements of channel 2 analogous to channel 1 6 1 7 1 8 9 For channel number 2 all is analog to channel number 1 BA931e Version 6 1a 66 SIUS AG cm 04 2001 Accessories 5 3 7 3 3 Synchronisation of several time control units Device 1 in this example the master device Interconnected slave device in this example devices 2 4 Connection to target 1 5 channel1 and targets 6 10 channel 2 Connection to target 11 15 channel1 and targets 16 20 channel 2 Connection to target 21 25 channel1 and targets 26 30 channel 2 Connection to target 31 35 channel1 and targets 36 40 channel 2 Cables pos 3 6 KP028 7 Cable pos 7 KP016 D Ue WN Switch position Master On Off channel 1 channel 2 Switch number 2 7 1 7 2 TCU 1 ON Intern Slave TCU 2 OFF Slave Slave TCU 3 OFF Slave Slave TCU 4 OFF Slave Slave numbers according to picture in chapter 7 3 2 on page 66 In this example all the all signal light from target 1 40 are controlle
47. t open Rear Paper tape coil cover Target front mask ISSF Air Rifle S20A022 Target front mask ISSF Air Pistol S20A023 Paper tape Target electronic Oa BWN OOND Paper tape coil Backing target S20D001 RJ45 socket Mounting mandrel 0 Projectile spread protection This target mounted with an force front frame and placed in a weather protected place can also be used for small bore weapons 50m disciplines BA931e Version 6 1a 12 SIUS AG cm 04 2001 Sets Devices And Targets 1 3 1 3 1 Assemble the Wall Mounted Target Holder WHS10 5 6 Screw the M4x10 thread pos G torsion security into the holder pos A Put the holder pos A onto the plate pos B and lock it with the counter sunk screw M8x20 Fix the mounting bracket for optional target illumination BLS20 with two M4x10 screws The inner thread who takes the star shaped knob has to be on the upper side Mount the butt holder from the front side onto the plate three M4x5 raised oval screws Tighten the screws from the rear side Screw in the star shaped knobs 1 3 2 Assemble Target and Butt to the Wall Mounted Target Holder AuBWN Hole for optional target illumination BLS10 Wall mounted target holder plate Stop screw for the mounting mandrel Hole for the mounting mandrel Butt Mounting mandrel BA931e Version 6 1a 13 SIUS AG cm 04 200
48. t airing or other circumstances which are not in the power of SIUS Defect of the system in which the device is installed This warranty doesn t restrict the national right of the user nor the rights of the user due to the contract made with the national SIUS representative UA Il Copyright The copyright of these Operating and Maintenance Instructions and all documentation delivered with the Scoring System remain with SIUS AG THESE DOCUMENTATION MUST NEITHER BE COPIED NOR MADE ACCESSIBLE TO THIRD PARTIES IN ANY MANNER WITHOUT THE EXPRESSIV APPROVAL OF SIUS AG SIUS AG Im Langhag 1 CH 8307 Effretikon Switzerland Tel 4152 3439191 e Fax 4152 343 12 14 Internet http Awww sius com E Mail admin sius com BA931e Version 6 1a 3 SIUS AG cm 04 2001 General I lll Concept and Application Possibilities The SA931 is a state of the art Automatic Electronic Target Scoring System based on the new LON Network Technology LONGMotorola Echelon This most modern network technology allows the use of RJ 45 cables which is the easiest and cheapest because it is the most used cabling with a free bus topology The installation is so easy that it can be made by the customer him self The installation of a 10 meter Air Rifle Pistol or a 50 meter Small Bore Rifle Pistol systems can be quickly installed requiring no special tools or special skills The use of highly integrated electronic components grant
49. the other lines must be printed out neatly and correctly The grid must be even and complete If characters or lines aren t printed completely the printer has to be exchanged If necessary contact your service centre ALAA aleTl oth d epee el wetl I bisai A TERE ath Paka HEAD Teak r tpj Cl gg gir AT Seth Ooo Seas EEE IKESA se PLR A PARS ESE Ohevcelalhi y hlo epee aye j e Te oe ee aS Somnus Ay a on aa 1 234 beep Ri el IL ere edi il m aurbHibicgenc iir zss rnBza TIIXI a LS EPE a ie npo 1 ZJ p xIIII LETRE ac T T ee A HEAD Jah Fete Ua Cie 2b eid dna s a aE CDEP Ye i 894117 Alle D yha g dim gee dave 1b 7 Li aaaa get i ain Sasa PvE a ee ae 144 43 l eet oe el en tp H e dale ee ee Ara i ernn nra BA931e Version 6 1a 62 SIUS AG cm 04 2001 Accessories 7 2 7 2 Remote control 7 2 1 General The remote control RC931 allows to place the control unit and the monitor M931 at separate locations for example control unit on the secretary s table and the monitor next to the shooter With the remote control the shooter can access the most important functions out from the shooting place 5 1 Monitor M931 9 4 Socket to connect the shot sensor 2 Remote control RC931 5 Cable KV014 L L length 3 Distributor MD931 6 Control unit CU931 BA931e Version 6 1a 63 SIUS AG cm 04 2001 Accessories 7 2
50. thlon disciplines F5 Free Free shooting programs for 10m range see chapter 4 5 BA931e Version 6 1a 32 SIUS AG cm 04 2001 The Optionen Menu 4 3 After the choice of the category of the 10m range type all the available disciplines are displayed 4 3 4 2 Range type 25m After you have chosen the range type 25m the following menu is displayed Range tupe 5m ASSF CISH F1 ISSF All ISSF disciplines which are shot on a 25m range F2 CISM All CISM disciplines which are shot on a 25m range After the choice of the category of the 25m range type all the available disciplines are displayed 4 3 4 3 Range type 50m After you have chosen the range type 50m the following menu is displayed F1 ISSF All ISSF disciplines which are shot on a 50m range F2 Biat Biathlon disciplines which are shot on a 50m range F3 SUI Swiss pistol disciplines P4 KK and GK FA FreeFree shooting programs for the 50m range type see chapter 4 5 After the choice of the category of the 50m range type all the available disciplines are displayed BA931e Version 6 1a 33 SIUS AG cm 04 2001 The Optionen Menu 4 3 4 3 4 4 Range type 300m After you have chosen the range type 300m the following menu is displayed F1 ISSF All ISSF disciplines which are shot on a 300m range F2 Free Free shooting programs on a 300m range see chapter 4 5 After the choice of the category of the 300m range type all the available disciplines
51. tion of all devices see chapter 4 4 4 3 on page 45 and reconfigure them see chapter 3 1 page 22 BA931e Version 6 1a 56 SIUS AG cm 04 2001 Troubleshooting 6 1 e If it isn t possible to load a shooting program discipline 1 If the status field on the monitor chapter 4 6 pos 12 on page 51 displays Offline The target attributed to the control unit is not connected or wrong configured Please ensure that all Plugs and cables are intact Check that the cables are connected corresponding to the installation scheme Check that the plugs are connected properly If necessary configure the target as described in chapter 5 2 exchange a target 2 The monitor displays the prompt Id Number Required Please enter a shooters id In this case the IdRq Identification Request function is on You can enter a shooter identification number see chapter 4 3 1 1 or turn off the IdRq see chapter 4 3 1 2 on page 36 Then select a new shooting program discipline chapter 4 2 on page 28 e If the target doesn t make the automatic tape feed Please ensure that the target still has some paper or rubber on the roll and that the tape isn t blocked by bullet splitters fractions of the projectile spread protection or by anything else The cover of the target has to be closed Then press s until all the ERROR No feed on target press escape messages are disappeared For each feed error one message e If the monitor dis
52. ugs 4 5 6 Close the device 7 8 Set the time and the date as described in chapter 4 4 3 2 Attention use only CR1620 3V batteries SIUS article number aa127 BA931e Version 6 1a 58 SIUS AG cm 04 2001 Troubleshooting 6 2 6 2 Exchange fuses 6 2 1 General Attention Before you open a device disconnect the power supply plug N Attention Before exchanging any fuses please check the condition of the Ks devices and cables and repair or exchange damaged parts 6 2 2 Dimension of the fuses device number dimension type and size NT931 10 1 5 x 20mm 4A fast CU931 1 5 x 20mm 2A slow TCU25 3 6 3 x 32mm 6 3A slow BA931e Version 6 1a 59 SIUS AG cm 04 2001 Accessories 7 1 7 Accessories 7 1 Printer D931 The optional thermo printer D931 is capable of making graphical presentations Connect the printer to the control unit CU931 see chapter 1 2 on page 10 The printer prints out the shot results table and if desired the current content of the monitor F2 button in chapter 4 1 on page 27 and the results of test functions see chapter 4 4 1 To turn the printer on and of use the main switch situated on the front side of the printer see position 13 on next page 1 Main switch of printer D931 2 Control lights POWER Device is switched on this light is on when printer is on SEL Selection this light is on when printer is on ALM Alarm this light is on if the pr
53. was made The control unit of the shooter firing the cross shot considers the shot as a fired and scores it as a 0 The lane receiving the cross shot does not score the cross shot but writes it into the log To print out the log see chapter 3 2 6 PrnL 4 6 2 Screen saver The SA931 system has an automatic screen saver incorporated If there is no activity on a lane shot fired or control unit manipulation for 15 min the screen saver starts automatically the SIUS chap walks around The screen changes automatically back to the activated mode if any shot is fired or any manipulation on the control unit is made BA931e Version 6 1a 51 SIUS AG cm 04 2001 How To Exchange Devices Of The Network 5 5 How to exchange devices of the network To exchange of devices there are three basic rules which have to be considered Always start exchang and configuration on the leftmost device Always exchange only one device at a time Unplug every device at the distribution box without disconecting the distribution box from the network trunk If you handle disaccording to these basic rules the network configuration can get mixed up If this happens all the devices of the network have to be reconfigured For this see chapter 2 2 2 to the targets disconnect ONLY here Koo m mm mg Network trunk i b ig M i disconnect ONLY here to the control units BA931e Version 6 1a 52 SIUS AG