1. the battery cover and reposition the protective holster EN 16 TENMARS TM 601N 603 604 Conditions This instrument is guaranteed for one year against material or production defects in accordance with our general sales conditions During the warranty period the manufacturer reserves the right to decide either to repair or replace the product Should you need for any reason to return back the instrument for repair or replacement take prior agreements with the local distributor from whom you bought it Do not forget to enclose a report describing the reasons for returning detected fault Use only original packaging Any damage occurred in transit due to non original packaging will be charged anyhow to the customer The warranty doesn t apply to Accessories and batteries not covered by warranty Repairs made necessary by improper use including adaptation to particular applications not foreseen in the instructions manual or improper EN 17 TENMARS TM 601N 603 604 combination with incompatible accessories or equipment Repairs made necessary by improper shipping material causing damages in transit Repairs made necessary by previous attempts for repair carried out by non skilled or unauthorized personnel Instruments for whatever reason modified by the customer himself without explicit authorization of our Technical Dept The contents of this manual may not be reproduced in any form whatsoever wi
2. TENMARS 3 Phase Rotation Motor Tester TM 601N 603 604 User s Manual HB2TM601N000 CONTENTS 1 eie nens 2 2 Application 2 Ss Features Ennis 3 4 Panel display ue 3 5 Howto 4 5 1 How to test the phases of AC 4 5 2 How to test the motor s direction of rotation 5 6 7 8 9 10 11 12 13 14 Easy t st eene idee 9 Electrical specifications 11 Accessories included 11 Safety precautions and procedures 12 The following symbols are used 14 Safety and maintenance standards 15 Battery 16 SOIVICG ea ue ere 19 TENMARS TM 601N 603 604 1 Preface Thank you for buying our excellent product Products available on the market are not very user friendly their test AC phase and motor phase are separated from each other have two sockets to be plugged out before use etc When you use the you will not have these troubles anymore and time is saved So enjoy 2 Application Test for poles of the 3 phase power source L1 A L2 B and L3 C and identify which phase for which wire Determine the 3 phase motor s direction of rotation clockwise or counterclockwise and the circuit sta
3. asure the motor s 3 wires with a multimeter and check if there is a disconnection between any 2 wires If the motor is disconnected change it The green lamp goes ON when the motor turns clockwise and the red lamp turns ON when it turns counterclockwise This suggests the wiring of L1 L2 and L3 is normal In this case skip to step 8 If the red lamp goes ON when the motor turns clockwise and the green lamp goes ON when it turns counterclockwise this indicates that the wiring sequence must be corrected Go to step 5 W Exchange L2 and L3 The green lamp goes ON when the motor turns clockwise EN 6 TENMARS TM 601N 603 604 and the red lamp goes ON when it turns counterclockwise this suggests the wiring of L1 L2 and L3 is normal In this case skip to step 8 If the red lamp goes ON when the motor turns clockwise and the green lamp goes ON when it turns counterclockwise this indicates the wiring sequence must be corrected Go to step 6 W Exchange L1 and L3 If the green lamp goes ON when the motor turns clockwise and the red lamp goes ON when it turns counterclockwise skip to step 8 If the red lamp goes ON when the motor turns clockwise and the green lamp goes ON when it turns counterclockwise this indicates the wiring sequence must be corrected Go to step 7 Exchange L1 and L2 If the green lamp goes ON when the motor turns clockwise and the red lamp goes ON when it turns counterclockwise this sugg
4. eads should be 4 feet long 3 CE120cm 4 feet Test leads should be removable and have alligator clips 3 EN 11 TENMARS TM 601N 603 604 9 Safety precautions and procedures This instrument conforms with safety Standard EN 61010 1 related to electronic measuring instruments For your own safety and to avoid damaging the instrument follow the procedures described in this instruction manual and read carefully all notes preceded by this symbol ___ For your own safety and to avoid damaging the instrument follow the procedures described in this instruction manual and read carefully all notes preceded by this symbol A When taking measurements Avoid doing that in humid or wet places Avoid doing that in rooms where explosive gas combustible gas steam or excessive dust is present EN 12 TENMARS TM 601N 603 604 B Keep you insulated from the object under test Do not touch exposed metal parts such as test lead ends sockets fixing objects circuits etc Avoid doing that if you notice anomalous conditions such as breakages deformations fractures leakages of battery liquid blind display etc Be particularly careful when measuring voltages exceeding 20V to avoid risks of electrical shocks EN 13 TENMARS TM 601N 603 604 10 The following symbols are used C AUTION refer to the instruction AN manual an improper use may damage the instrument or its compo
5. ests the wiring of L1 L2 and L3 is normal In this case skip to step 8 EN 7 TENMARS TM 601N 603 604 Once the green lamp goes ON when the motor turns clockwise and the red lamp goes ON when it turns counterclockwise the 3 phases are correct Then the motor s R S T can be connected to the power system s L1 L2 and L3 Now your motor can run correctly EN 8 TENMARS TM 601N 603 604 6 Easytest 6 1 1 Motor turning test 6 1 2 Wiring and lamps ff i fi um TN N EN 9 TENMARS TM 601N 603 604 Ooff Onot defined Phase indication IL L2 L3 phase rotation Rotate right CO Power on Rotate left 91 1 69 g L1 missing 69 L2 missing L3 missing EN 10 TENMARS TM 601N 603 604 BH m m mum gt Electrical specifications Battery life about 50 hours Operating Temperature 5 40 80 RH Storage temp amp RH 10 C 60 C 70 RH Overvoltage category CAT IV 600V CAT III 1000V Dimensions with holster 143x68x35 mm Weight including battery about 150g Inter phase voltage 45V AC up to 600 AC Signal Frequency Range 45 to 400 Hz Test Currents In per phase less than 3 5 mA Motor POWER 6W 160W Accessories included User manual 9V battery NEDA 1604 IEC 6F 22 JIS 006P 1carrying case Test l
6. f itis the ER red lamp it means L1 L2 and L3 are wired incorrectly You must correct them before proceeding to step 3 Exchange L2 and L3 If the green lamp goes ON it means the 3 phases are correct In this case skip to step 6 If the red lamp ER goes ON it means the 3 phases are wired incorrectly You must EN 4 TENMARS TM 601N 603 604 correct them before going to the next step Exchange L1 and L3 If the green lamp goes ON it means the 3 phases are correct In this case skip to step 6 If the red lamp ER goes ON it means the 3 phases are wired incorrectly You must correct them before going to the next step Exchange L1 and L2 If the green lamp goes ON it means the 3 phases are correct In this case skip to step 6 Note the definition for L1 L2 and L3 each 5 2 How to test the motor s direction of rotation Make sure the motor s power source has been removed Connect the test wire to the motor terminal In each test press the power button then check the indicators on the panel when the motor is not turning the red lamp is ON The green lamp goes ON when the motor EN 5 TENMARS TM 601N 603 604 turns clockwise and the red lamp goes ON when it turns counterclockwise Normal skip to step 8 If the motor turns clockwise and counterclockwise and the red lamp remains ON the red and green lamps do not go ON alternately this suggests one wire is disconnected or not connected well Please me
7. meter Anemometer Lan cable tester CO2 meter Solar power meter Radiation meter Clamp meter Multimeter Phase Rotation test Digital Insulation tester Our products of high quality are selling well all over the world TENMARS ELECTRONICS LTD 6F 586 RUI GUANG ROAD NEIHU TAIPEI 114 TAIWAN E mail service tenmars com http www tenmars com
8. nents Danger high voltage risk of electric shock Double insulated meter AC voltage or current o P DC voltage or current 1 Earth EN 14 TENMARS TM 601N 603 604 11 Safety and maintenance standards The instrument complies with UL61010 1 and CSA C22 2 No 61010 1 between ground and input terminal and EN 61010 1 2001 and EN61557 Operating altitude below 2 000m Operating environment for indoor use expose to pollution level 11 This is a precision device During use or storage do not go beyond its spec to prevent any possible damage or danger Do not put this device in direct sunlight or where it is hot and or damp Remember to turn OFF the power after use For long storage remove the battery to prevent the battery from leaking to cause damage to the parts inside Clean the device with a dry soft cloth Wet cloths liquid and water are prohibited EN 15 TENMARS TM 601N 603 604 12 Battery Replacement Battery Replacement When the symbol Low battery LED is displayed batteries need replacement Before replacing batteries disconnect the test leads from any energized circuits to avoid electrical shocks Turn OFF the meter and disconnect the test leads from the input terminals Unscrew the battery cover and remove the battery W Insert a new battery of the same type 9V NEDA1604 JIS006P IECGF22 observing the proper polarity re screw
9. thout the manufacturer s authorization Our products are patented and our logotypes registered We reserve the right to modify specifications and prices in view of technological improvements or developments which might be necessary EN 18 TENMARS TM 601N 603 604 13 Service Shouldn t the instrument work properly before contacting your distributor make sure that batteries are correctly installed and working check the test leads and replace them if necessary Should you need for any reason to return back the instrument for repair or replacement take prior agreements with the local distributor from whom you bought it Do not forget to enclose a report describing the reasons for returning detected fault Use only original packaging Any damage occurred in transit due to non original packaging will be charged anyhow to the customer The manufacturer will not be responsible for any damage to persons or things EN 19 TENMARS TM 601N 603 604 14 End of life Caution this symbol indicates that equipment and its accessories shall be subject to _____ separate collection and correct disposal EN 20 TENMARS lt gt Professional Electrical and Environment Test amp Measurement Instruments Battery Capacity Impedance Tester TACHO Meter LED light meter Temperature amp Humidity meter Infrared Thermometer Sound level meter Light meter EMF meter UV Light meter RF meter Hot wire Anemometer CO
10. tus of the motor wires EN 2 TENMARS TM 601N 603 604 3 Seep Features In each test Push button turn on the meter push button again to turn off the meter or auto shut off after 15 minutes TM 601N Check the wires of the power cord L1 L2 and L3 through the 3 red lamps which indicate if each wire is connected well Check if L1 L2 and L3 are in place the 3 motor wires the motor s direction of rotation and the ER red green OK indicators When the battery is low an indicator will turn ON to remind you to replace it hold the power button and check the panel indicator TM 603 604 Two UL 500mA 700V fuse TM 601N Waterproof resist IP67 TM 601N Panel display lamps L1 L2 and L3 ER red green OK indicators Low battery indicator see step 10 EN 3 TENMARS TM 601N 603 604 5 How to operate 5 1 How to test the 3 phases of AC Let your crocodile clip clamp the 3 phase power terminal In each test hold the power button and check the indicators on the panel If L1 L2 and L3 are lit it means normal In this case skip to step 2 If one of them remains unlit L1 for example it means the wire for L1 is disconnected or in power failure mode You may check visually or with a multimeter if the wire is connected well Next check if the red or green lamp is lit If itis the green lamp it suggests L1 L2 and L3 are correct for their phases In this case skip to step 6 I