Home

Anaheim Scientific H500 - RGB Color Analyzer

image

Contents

1. 2 Continue to hold the Color Sensor Element 4 15 Fig 1 in place while the meter makes its measurement During the measurement you will see the Mesu marker on the top of the LCD The measurement process takes approximately 5 seconds 3 After the measurement you the RGB values on the LCD and the Mesu marker on the LCD will disappear 4 5 HSL Measurements 1 For HSL measurements follow steps from section 4 4 then press the RGB HSL Button 4 7 Fig 1 This will display the HSL values A separate measurement is not necessary 2 You toggle between values by pressing the RGB HSL Button 4 7 Fig 1 HSL Considerations The HSL color is more closely approximates how the human eye distinguishes a color compared to the common RGB color value Hue is what distinguishes on color from another You can think of Hue a specific color Saturation is how much color or the purity of the color is present Luminance is how bright or intense the color is 4 6 REL Relative Measurements After making a measurement it is possible to subtract the measured values from the display to allow you to easily measure the difference of two color samples 1 After measurement has been made press the REL Button 4 6 Fig 1 and the LCD should display all zeros 2 Now perform your measurement on the new sample The resulting displayed values will be the difference between the two colors The values will be flashing on the scre
2. Congratulation on your purchase of this Anaheim Scientific RGB Color Analyzer with HSL measuring capabilities The H500 is equipped with an external sensor probe having a 45 0 color measuring geometry It is designed around a microprocessor technology that uses a spectral analysis method to determine the color of the area under test The model H500 has excellent repeatability due to the spectroscopic analysis technique used 1 1 Features Measure both RGB and HSL levels Easy to use Relative REL feature allows the comparison of to color samples Two year warranty 1 2 Applications Check color levels of Plastics Textiles Paper Paints and Leathers Quality control in production and manufacturing Comparisons of color samples against color standards Check reference color values of CRTs LCD monitors and light lamps 2 Safety Information A Read the following safety information carefully before attempting to operate or service the meter Only qualified personnel should perform repairs or servicing not covered in this manual 2 1 Cautions DO NOT submerge the products mentioned in this manual in water or any other types of liquids E This product is not designed for use in medical applications The product can only be used to measure body temperature simply for reference 2 2 Safety Symbols Dangerous refer to this manual before using the meter C Conforms to requirements of European Union and European Fare Trade Associa
3. color to be measured Ensure that the front of the color sensor head is flush with the surface 4 Follow the appropriate steps that appear in sections 4 4 through 4 6 to continue your measurements 4 3 Light Emitting Sample Measurements This mode of operation is design for use on materials that emit light such as a LCD or CRT The H500 is primarily designed to work on non light emitting materials Any values measured with this instrument in this mode should be considered estimations and are not actual values 1 Connect the Probe Plug 4 17 Fig 1 to the Input Socket 4 9 Fig 1 2 Power the meter on by pressing the Power Button 4 2 Fig 1 The display will show zero values 3 Press the Light On Off Button 4 8 Fig 1 4 Use the Probe Handel 4 17 Fig 1 to position the Color Sensor Element 4 15 Fig 1 over the color to be measured Ensure that the front of the color sensor head is flush with the surface 5 If the LEDs near the Color Sensor Element 4 15 Fig 1 turn on then the meter is set to still measure non light emitting samples Press the Light On Off Button 4 8 Fig 1 to turn off the LEDs 6 Follow the appropriate steps that appear in sections 4 4 through 4 6 to continue your measurements 4 4 RGB Measurements 1 For RGB measurements follow steps from section 4 2 and then press the Measurement Trigger 4 16 Fig 1 or the Test Button 4 3 Fig 1
4. ANAHEIM SCIENTIFIC Painting Textile Paper Leather INSTRUCTION MANUAL Model H500 RGB Color Analyzer Table of Content 1 Product Introduction 3 FECC S araa 3 1 Z AD DIUCALIONS 3 2 Safety Information 4 ZAG vers 4 2 2 Safety 4 9 Specife oN S 5 4 Operation 6 AUN Diag aM heath ttn 6 4 2 Non Light Emitting Sample Measurements T 4 3 Light Emitting Sample Measurements T 4 4 amp HSL Measurements T 4 5 HSL Measurement 7 4 6 REL Relative Measurements 8 5 Calibration Procedure 8 6 RS232 PC Serial Interface Information 9 Pa MAINtGNaNne a 11 7 1 Battery 11 122 SNOOUNG 11 8 Service Information 12 9 Warranty Information 13 To see all available accessories and downloadable software please visit www anaheimscientific com 1 Product Introduction
5. en to notify you that you are reading REL values 3 Press the REL Button 4 6 Fig 1 to exit the REL mode 5 Calibration Procedure 1 Set meter to be used to measure RGB by following steps 4 2 and 4 4 2 Lay the White Color Calibration Card included with your H500 on to a flat surface so you will have access to the White Card 3 Place the Color Sensor Element 4 15 Fig 1 over the White Card making sure that it is flush with the card surface 4 Simultaneously press the Function Button 4 4 Fig 1 and the CAL Button 4 5 Fig 1 then release the buttons to commence calibration It is important to keep the probe in place during the entire process 5 You will see the following sequence displayed on the LCD R CAL Wait approx 30 seconds y R CAL 1023 Wait approx 10 seconds y Wait approx 10 seconds Generate 3 beep sound and finish the calibration procedures 6 RS232 PC Serial Interface Information This instrument has RS232 PC serial interface via a 3 5 mm terminal 4 12 Fig 1 The data output is a 16 digit stream which can be utilized for user s specific application A RS232 lead with the following connection will be required to link the instrument with the PC serial port Visit www anaheimscientific com to see any available downloadable software for your instrument Meter PC QW D Connector Center Pin 3 5 mm jack plug Ground shield resister The 16 d
6. ican shipping fees please contact Anaheim Scientific Anaheim Scientific 22820 Savi Ranch Parkway Yorba Linda CA 92887 www anaheimscientific com 714 921 9095 Include with the returned instrument your complete return shipping address contact name phone number and description of problem 12 9 Limited Two Year Warranty Anaheim Scientific warrants to the original purchaser that its products and the component parts thereof will be free from defects in workmanship and materials for a period of two years from date of purchase from an authorized Anaheim Scientific distributor Anaheim Scientific will without charge repair or replace at its option defective product or component parts Returned product must be accompanied by proof of the purchase date in the form of a sales receipt To obtain warranty coverage in the U S A this product must be registered by completing the warranty registration form on www anaheimscientific com within fifteen 15 days of purchase Exclusions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs The warranty is void if the serial number is altered defaced or removed Anaheim Scientific shall not be liable for any consequential damages including without limitation damages resulting from loss of use Some States do not allow limitations of incidental or consequential damages So the above limitation or exclusion may n
7. igit data stream will be displayed in the following format D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1D0 Each digit indicates the following status D12 amp D11 D8 to D1 Start Word 4 When send the R color value 1 When send the G color value 2 When send the B color value 3 When send the H color value 4 When send the S color value 5 When send the L color value 6 Note Send these values in sequence Indicator for Display R 70 H 42 Polarity 0 Positive 1 Negative Decimal Point DP position from right to left 0 No DP 1 1DP 2 2DP 3 3DP Display reading D1 LSD D8 MSD Example If the display reading is 1234 then D8 to D1 is 00001234 Do End Word RS232 Setting Baud Rate 9600 No Parity Data bit 8 Data bits Stop bit 1 Stop bit 7 Maintenance 7 1 Battery Replacement 1 When the LCD display shows the low battery symbol It is necessary to replace the battery The specifications listed for this instrument do not apply when the low battery symbol is displayed 2 Open the Battery Compartment 4 12 Fig 1 by first loosening the single battery cover screw 3 Replace the batteries with good batteries noting the correct polarity Replace Battery Compartment 4 12 Fig 1 and battery cover screw Ensure the cover is securely fastened 7 2 Trouble Shooting Low Value Measurements 1 If during a Non Light Emitting Sample Measurement the meter di
8. not apply to type 2 materials Approximately after three minutes DC 9V Battery type 006P MN1604 PP3 or equivalent 6 4mA standby 32mA measurement AC Adapter not included Dimensions approx Included Accessories Instruction manual calibration card battery carrying case Specifications and information is subject to change without notice For the most current and up to date product information please visit www anaheimscientific com Measurement Sample Material Types 4 Operating Instructions 4 1 Unit Diagram 4 1 Pp Ppp N OWN 4 1 Display 4 2 Power Button 4 3 Test Button 4 4 Function Button 4 5 CAL calibration Button 4 6 REL relative Button 4 7 RGB HSL Button 4 8 Light On Off Button 4 9 Input Socket RS232 Socket DC 9V Adapter Input Socket Battery Compartment Stand Tripod Screw Mount Color Sensor Element Measurement Trigger Probe Handel Probe Plug 4 2 Non Light Emitting Sample Measurement This mode of operation is design for use on materials that do not emit light The H500 15 primarily designed to work on non light emitting materials 1 Connect the Probe Plug 4 17 Fig 1 to the Input Socket 4 9 Fig 1 2 Power the meter on by pressing the Power Button 4 2 Fig 1 The display will show zero values 3 Use the Probe Hande 4 17 Fig 1 to position the Color Sensor Element 4 15 Fig 1 over the
9. ot apply to you This warranty gives you specific rights and you may have other rights which vary from state to state Anaheim Scientific 22820 Savi Ranch Parkway Yorba Linda CA 92887 www anaheimscientific com 714 921 9095 Anaheim Scientific 22820 Savi Ranch Parkway Yorba Linda CA 92887 U S A http www anaheimscientific com Printed in Taiwan Ver 1 1 081209 2009 Anaheim Scientific Corporation
10. splays unusually low RGB values check and make sure both LEDs are turning on when you press the Measurement Trigger 4 16 Fig 1 or the Test Button 4 3 Fig 1 2 If neither LEDs turn on follow steps from section 4 2 3 If only one LED turns on then the unit needs repair Unit will not power on or buttons not performing specified functions 1 Replace the batteries following step from 7 1 2 Perform calibration process from section 5 8 Service Information Warranty Service Please return the product in the original packaging with proof of purchase to the address below Clearly state in writing the performance problem and return any leads probes connectors and accessories that you are using with the device Non Warranty Service Return the product in the original packaging to the address below Clearly state in writing the performance problem and return any leads probes connectors and accessories that you are using with the device Customers not on open account must include payment in the form of a money order or credit card For the most current repair charges please visit www anaheimscientific com and click service repair Return all merchandise to Anaheim Scientific with pre paid shipping The flat rate repair charge for Non Warranty Service does not include return shipping Return shipping to locations in North American Is included for Warranty Service only For overnight shipments and non North Amer
11. tion EFTA lt Battery level is low Don t dispose this product as unsorted municipal waste This instrument conforms to the following standards EN61326 Electrical equipment for measurement control and laboratory use IEC61000 4 2 Electrostatic discharge immunity test 61000 4 3 Radiated radio frequency electromagnetic field immunity test IEC61000 4 8 Power frequency magnetic field immunity test 3 Specifications LCD size 2 3 x 1 3 59 x 34mm Measuring Principle For non light emitting sample measurements such as textiles or paper a defined light source illuminates the sample and reflected surface light is spectrometrically analyzed For light emitting sample measurements such as CRT or LCD the light source from the sample is spectrometrically analyzed directly Color Sensors Three color photo transistors One for all three Red Blue amp Green colors Measurements RGB Value R Red value 0 to 1023 G Green value 0 to 1023 B Blue value 0 to 1023 HSL Value H Hue value 0 to 1 000 S Saturation value 0 to 1 000 L Luminance value 0 to 1 000 repeated on the same sample tested ten times within two minutes Type 1 Non light emitting material such as Textiles Paint etc Type 2 Light emitting material such as CRT LCD Lamp etc Important Note The H500 is designed for measuring type 1 materials Type 2 materials are for reference only any accuracies or stated capabilities do

Download Pdf Manuals