Home

Manual - Wassermann Dental

image

Contents

1. D 21031 Hamburg work station for dental applications Model Automatic stand for external devices 146150 146140 Automatic stand for WP Ex 2000 Ex 3000 190420 Automatic stand for Cemat NT 146103 Automatic stand for WP Ex 80 Applicable DIN EN 61010 1 standards DIN EN 61000 6 3 DIN EN 61000 6 1 DIN 45635 1 DIN EN 60335 1 Hiermit wird best tigt dass die oben bezeichnete Maschine den genannten EG Richtlinien entspricht Diese Erkl rung wird ung ltig falls die Maschine ohne unsere Zustimmung ver ndert wird This is to confirm that the above mentioned machine complies with the described EC rules This declaration becomes invalid if the machine is modified without our approval Cette machine est conforme aux normes en vigueur de la Communit Europ ene Cet avis est nul et non avenant si cette machine est modifi e sans notre accord Esta m quina anteriormente mencionada cumple con los limites requeridos por el reglamento EC Ahora bien esta declaraci n quedar invalidada en caso de realizar modificaciones al aparato sin nuestra aprobaci n Hiermee wordt bevestigd dat bovengenoemde machine voldoet aan de voorgeschreven EU normen Deze verklaring verliest geldigheid als er zonder onze uitdrukkelijke toestemming wijzigen aan de machine worden aangebracht Place date Hamburg 01 11 12 Company stamp ro ur dh LINEN GMBH e ES pi MAS ij Vac Er ree pe 4031 Hamburg Y r A Audorfiwes Signature Wilfried Wassermann Manag
2. WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor Automatic stand Automatic stand for fine blasting unit Cemat NT Automatic stand for polishing compact unit WP Ex 80 USER MANUAL C WASSERMANN DENTAL MASCHINEN GMBH WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor Dear customer Thank you for choosing a product from the Wassermann range Wassermann Dental Maschinen incorporates the highest standards of quality and the latest technology In order to enjoy maximum performance and years of trouble free operation please read this user manual carefully before you connect this device and start work and operate the device according to the recommended guidelines The operation safety and the functionality of this device can only be guaranteed if you follow both the general safety guidelines and the applying laws to prevent accidents as well as the precautions given in this user manual We are not liable for any damages which occur due to inappropriate usage or faulty operation of this device Make sure that anyone using this device has read and understood this user manual Keep this user manual in a safe place where it can be referred to as required at any time Company address Wassermann Dental Maschinen GmbH Rudorffweg 15 17 D 21031 Hamburg Germany Phone 49 0 40 730 926 0 Fax 49 0 40 730 37 24 E mail info wassermann dental com URL http www wassermann denta
3. and take care that you will not bruise your limbs In sitting position do not cross the legs when moving down the stand Do not wear shoes with thick soles Do not use chairs with arm rests The stand is only allowed to be moved by the user self 2 3 Responsibility for operation or damage The responsibility for operating the device lies exclusively with the owner or user if said device is incorrectly serviced maintained or altered by persons not employed by an authorised dealer or if the device is used in a manner contrary to its specified purpose The unit has to be maintained and operated in accordance with this user manual Wassermann Dental Maschinen GmbH is not responsible for damage arising from the nonobservance of these instructions Warranty and responsibility provisions contained in the sales and supply conditions of Wassermann Dental Maschinen GmbH are not extended by these instructions WASSERMANN DENTAL MASCHINEN Die Basis fur Ihr Labor 3 Application The Automatic Stand is a motor driven lifting table It enables different user to work in an ergonomic position adjusted to every ones own necessities The Automatic Stand is designed for our units WP EX 2000 and Cemat NT But by using a special supporting frame it can also be used with other machines Only use the device for this type of application 4 Before starting 4 1 Transport Before transporting the unit ensure that it has been
4. d foot to move the Automatic Stand to the desired position 3 The Automatic Stand can be stopped and switched off in any position 4 Power is only supplied when the main switch is switched on 5 Switch off the main switch after using or finishing work O The integrated self locking main spindle prevents the Automatic Stand from inadvertent saging down The motor of the Automatic Stand is equipped with an overload protection to prevent the motor from damages caused by overheating Should the stand stop suddenly during operation the protection switch is activated and will be reset automatically after a few minutes cooling down Then the unit will function as normal O Disconnect the power plug when not using the unit for a long period of time A Attention Danger of bruise When moving the stand take care that you will not bruise your limbs In sitting position do not cross the legs when moving down the stand Do not wear shoes with thick soles Do not use chairs with arm rests The stand is only allowed to be moved by the user self WASSERMANN DENTAL MASCHINEN 0 Die Basis f r Ihr Labor 6 Operation 6 1 General operating instructions All instructions for using the unit whether in verbal or written form are based on our own experience and experimentation and can only be regarded as guidelines 1 Switch on the main switch 2 Use the foot switch at the bottom of the stand foot to mo
5. damaging the paintwork or removing the lettering The equipment should be cleaned at regular intervals to ensure trouble free operation It requires only normal cleaning sponge damp cloth mild detergent and no further chemical additives 10 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 8 2 Maintenance The unit does not require any servicing Just make sure that the device is kept clean 8 3 Warranty The warranty period for our equipment is 12 months If faults occur within the warranty period contact your dental depot or get in touch directly with our service department Your equipment should only be operated in perfect condition If faults occur which could harm operators or third parties the unit should not be used until it has been fixed This warranty does not cover damage caused by improper use external mechanical causes transport damage or interference with the unit by unauthorized persons 8 4 Spare parts If necessary please contact our service hotline phone 0049 0 40 730 92 6 0 11 WASSERMANN DENTAL MASCHINEN Die Basis fur Ihr Labor 8 5 Scope of delivery Accessories Lieferumfang Item no Automatic stand for external devices Item no 146150 Automatic stand for WP Ex 2000 Ex 3000 Item no 146140 Automatic stand for Cemat NT Item no 190420 Automatic stand for WP Ex 80 Item no 146103 Zubeh r Item no Additional drawer 146060 630 x 90
6. he adjustment is done through a powerful motor and almost silent This stand can perfectly be used in combination with the Polishing Compact Unit WP Ex 2000 or our Sand Blasting Unit Cemat NT including supporting frame for a Dust Extraction SG 1 2 but also units of other manufacturers which do not exceed 120 kg can be placed on this Automatic Stand m automatic stand for ergonomically optimised working m adjustable from 740 1090 mm m maximum applied force of 120 kg makes it suitable for almost any equipment on the market m motor overload protection as standard 2 Safety guidelines 2 1 Safety symbols used in this manual Warning This is a warning of risk situations and dangers Failure to observe this warning could be life threatening These warnings has to be observed o Information This symbol draws your attention to specific features that has to be observed WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 2 2 Safety guidelines Configuring and operating this equipment requires precise knowledge and observance of the instructions in this user manual The equipment is designed only for its intended application WARNING Servicing and repairs should be carried out only by authorised specialists Disconnect the power plug before starting any maintenance work i Make sure that the equipment is connected to the correct power source Attention Danger of bruise A When moving the st
7. ing Director 14 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor Notes WASSERMANN DENTAL MASCHINEN Die Basis fur Ihr Labor Wassermann Dental Maschinen GmbH Rudorffweg 15 17 D 21031 Hamburg Tel 49 0 40 730 926 0 Fax 49 0 40 730 37 24 info wassermann dental com www wassermann dental com
8. l com Erstellt 01 11 2012 msc Version 1 Auftrag 146150 146140 190420 146103 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor Contents AA A A a 4 2 Safety QuUldelnes ersehen ee 4 2 1 Safety symbols used in this manual 22 4044040004 eeneseeecneeneneeeneennescceeeeeeenenens 4 2 2 Safety g idelNe ee ee 5 2 3 Responsibility for operation or damage nn en 5 oy esent A A E E 6 4 Before starti e 6 AT AWTS m c a 0 E Eaa 6 A e E oO EA anne 7 4S Strage mm HT a 7 5 Installation SAUS a 8 OOO A a ii avia 9 6 1 General operating Instructions uec Ebr i ret bee Ce ripa dra beso E EPOR rbi eene 9 l Iroubleshoolngsssn se eee 10 8 Care and MAMI Om 10 A een 10 8 2 Malntefali6B id Mi Me eda ni ES Rot 11 8 3 Warranty eod Seiten e q MU E I Eq I E 11 8 4 Spare AS MENT Trpo cc 11 8 5 Scope of delivery Accessories ussssssssssssssseeee eee nnne 12 8 0 RepallS A nn rD ER 12 SN O a ER 13 TOES Conformity Certificate es Mem 14 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 1 Features The Automatic Stand is a variable lifting table which can be adjusted by the user for individual postures to enable comfortable protracted working periods Working is possible in sitting as well as standing position T
9. unplugged from the power socket Make sure that it is packed correctly in order to avoid accidental damage Be sure to check for any transport damage when unpacking the goods Note down any damage if found WASSERMANN DENTAL MASCHINEN Die Basis fur Ihr Labor 4 2 Installation Open the box remove the packing materials and carefully lift out the device and accessories Check the included accessories Install the device in a place where it will not block the working area and the functionality take the dimensions into account The device has to stand horizontally on a steady and even surface Uneveness of the bottom can be trued up through the rubber feet a wrench is enclosed see fig Place the unit e g the WP EX 2000 onto the supporting frame D Do not install the unit outdoors or in places without proper ventilation Before start up be sure the device reaches room temperature 4 3 Storage If the unit is to be stored for an extended period protect it from moisture and dust WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 5 Installation Start up Before starting the unit connect up the following Connect the unit to the connection box power cable Insert the power plug into the socket making sure that the mains and the unit operate on the same voltage 220 240 V 50 60 Hz 1 Switch on the main switch 2 Use the foot switch located at the bottom of the stan
10. ve the stand to the desired position 3 Press the foot switch until the stand has reached the desired position max 126cm Press down the right side arrow Press down the left side arrow pointing to the front of the foot pointing to you of the foot switch switch The Automatic Stand moves down The Automatic Stand moves up WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 7 Troubleshooting Fault Cause Remedy Stand position cannot be Power plug is not Check the power plug and connect it changed connected Main switch is not Check the main switch and set it to the Switched on On position Stand stops suddenly Motor overload Wait and let the motor cool down a few protection is activated minutes Protection switch will be reset due to overheating automatically Stand does not start Stand is overloaded The axial load must not exceed 120 kg moving Improper application Stand must be used for the determined purpose only 1 If the above recommendations do not solve the problem contact your dental depot or our service department 8 Careand maintenance 8 1 Cleaning Disconnect the power plug before starting any maintenance work The identification plate has always to be kept in easily legible condition and has not to be removed e Remove external dirt from time to time with some form of cold cleaner Use only cold cleaners to avoid
11. x 555 mm WP Ex 2000 Ex 3000 8 6 Repairs Servicing or repairs to the unit has only to be carried out by qualified technicians Only original spare parts are to be used Responsibility for the product is voided if unauthorised persons alter it or if inappropriate components are installed 12 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 9 Technical data Automatic stand Item no 146150 for external devices Automatic stand Item no 146140 WP Ex 2000 Ex 3000 Automatic stand Item no 190420 Cemat NT Automatic stand Item no 146103 WP Ex 80 Voltage 220 240 V 50 60 Hz Power consumption B 1 A Output 660 W Wx min Hx D 630 x 740 x 540 mm W x max Hx D 630 x 1090 540 mm Weight 9 7 kg 34 5 kg 3 8 kg 39 7 kg Stroke 50 mm Max load 1200 N axial 120 kg Lifting speed a 20 mm sek Other voltages on request The noise level of the unit amounts to lt 70 dB A O The technical data are subject to change without prior notice 13 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 10 EC Conformity Certificate in accordance with 2006 95 EG low voltage guidelines and 2004 108 EG EMV guidelines and 2006 42 EG machinery guidelines Manufacturer WASSERMANN Product description Electrical lifting table Dental Maschinen GmbH for an ergonomically Rudorffweg 15 17 designed laboratory

Download Pdf Manuals

image

Related Search

Related Contents

Communications System Analyzers  SA−83D設置管理基準書 - 放射線防護グローブ X線 立位撮影台 平面  Custom Theatre SA1000 CT SW10 CT SW12 CT  Manuel d`utilisation FLYBOX contrôleur de flaps  Toshiba 55UX600U 55" Full HD Black LED TV  Bedienungsanleitung - GT  H8SX Family E10A Emulator Additional Document for User`s Manual  SMART- TURBO  Sonómetro integrador tipo 2 com protocolos de medição  取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file