USER MANUAL & HYGIENE RECOMMENDATION
Contents
1. ight seal after at least 30 seconds with the O2 infeed open close the valve on the O2 bottle and wait 1 minute If the pressure gauge reading remains constant the connection is tightly sealed Reopen the regulator on the O2 bottle Dispense 2 3 litres of oxygenated water The water cooler is ready to use HYGIENE RECOMMENDATION l The customer is responsible for the hygiene and cleanliness of the installed water coolers We recommend regularly cleaning the outer surface 2 Water dispenser cleaning frequency a Wipe down the water cooler and the drip tray daily with a single use cloth and empty the drip tray if necessary b The water outlet must be disinfected every 2 days with a hygiene spray food compatible Point the spray at the water outlet soray and allow around 2 minutes to take effect then draw around 0 5 litres water to rinse c The blue protective cap needs to be cleaned every or 2 weeks The service technician will instruct the people responsible for the water cooler in the method of cleaning The blue protective cap must not be removed Wet the single use cloth with the spray then carefully and effectively clean all grooves and indentations in the protective cap 3 If the water cooler is not used over the weekend or during public holidays we recommend the following procedure before using it again e disinfect the outlet as described in point 2b draw off 2 litres of water distributed through the vario
2. oxymount The freshness of water USER MANUAL amp HYGIENE RECOMMENDATION FOR PROFI WATER COOLERS SETTING UP PROFI 15 PROFI 90 WATER COOLERS ATTENTION follow the correct sequence O2 or CO2 connection depending on the cooler type 1 Connect the water pipe to the water cooler check for any leaks and keep the water tap closed 2 Connect the power supply and open the water tap 3 Initial installation of gas bottle s O2 bottle oxygen CO bottle carbon dioxide Connect the O2 bottle then open the Connect the CO2 bottle open the valve and valve and adjust the pressure on the adjust the pressure to 2 8 bar The pressure may pressure gauge wheel with the notch at fall slightly over the next two days in which case 0 05 I min After opening wait for 2 3 it needs to be readjusted The carbon dioxide minutes until the cooling generator stops level will be properly adjusted by our service running technician during setup 4 The first few litres of water drawn are not suitable for consumption as they do not yet contain the full oxygen or carbon dioxide level OVERVIEW OF OPERATING BUTTONS Still water Still water Carbonated Oxygenated Service non cooled cooled cooled cooled Service technician no Water type c Service W1 W2 W3 W4 CHANGING GAS BOTTLES Changing the carbon dioxide bottle CO2 1 Close the valve on the CO2 bottle 2 Press and hold the W3 water type button carbonated cooled until the pre
3. ssure gauge reads zero This releases the pressure allowing the pressure regulator valve to be unscrewed from the COd2 bottle using the supplied spanner 3 Screw the pressure regulator on the new CO2 bottle and tighten with the supplied spanner 4 Open the regulator on the CO2 bottle Attention do not change the setting on the front adjuster 2 8 bar basic setting since this will alter the carbon dioxide and water balance 5 Check for a tight seal close the regulator on the CO2 bottle and wait 1 minute If the pressure gauge reading remains constant the connection is tight Reopen the CO2 bottle valve 6 Dispense 2 3 litres of carbonated water 7 The water cooler is ready to use CHANGING O2 BOTTLE amp HYGIENE RECOMMENDATION gt gt gt Oxymount AG TOdistrasse 53 Phone 41 0 44 783 86 66 info oxymount ch CH 8810 Horgen Fax 41 0 44 783 86 67 www oxymount ch oxymount The freshness of water USER MANUAL CONTINUED Changing the oxygen bottle O2 l Zs Close the valve on the O2 bottle Press and hold the W4 water type button oxygenated cooled until the pressure gauge reads zero This releases the pressure allowing the pressure regulator valve to be unscrewed from the O2 bottle without any tools Screw the pressure regulator valve on the new O2 bottle and hand tighten Open the valve on the O2 bottle Attention do not change the setting on the front adjuster 0 05 min basic setting Check for a t
4. us water options and throw away the water is now suitable for drinking e if the water cooler is to be left unused for a longer period holidays etc for 14 days and longer please inform the Oxymount Service Centre Tel 41 0 44 783 86 66 in plenty of time beforehand 4 Water bottle hygiene a When drawing water do not hold or press the water bottle against the water cooler outlet Always place the drinking bottle on the drip tray and press the CO2 O2 or still water button b Pour any remaining water out of the drinking bottle in the evening c Leave the clip fastener open overnight to allow the bottle to dry out d Do not mix any sweeteners in the drinking bottle e Wash out the drinking bottle with hot water before the weekend f Spare rubber seals are available for the bottle clip fastener to replace worn seals Oxymount AG TOdistrasse 53 Phone 41 0 44 783 86 66 info oxymount ch CH 8810 Horgen Fax 41 0 44 783 86 67 www oxymount ch
Download Pdf Manuals
Related Search
Related Contents
Pressure Reference Type P USER MANUAL Sutorbilt Legend Series 6"-8" Manual - Enviro 4CH ANEMOMASTER Compact Laser Diode Module Digitus 1m Cat5e SF/UTP WARNING: - The First Years DOSSIER INFORMACIÓN TÉCNICA FABRICANTE Samsung DVD-HD936 User Manual to the PDF file. Samsung WF906U4SAGD/SG Manuel de l'utilisateur Copyright © All rights reserved.
Failed to retrieve file