Home

Firmware Update/Installing Options

image

Contents

1. gt TsmxBootWare elf Bugfix in OHCI1394 sys driver concerning long term stability in multicore and multithreading environments gt Firmware amp Drivers R amp S RF Receivers TSMx Tsmxleee1394DriverV10_53 0 2 zip Bugfix GSM synchronisation Host PC Software related ViCcom 13 Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 Version 12 77 12 10 2009 Fixed in GSM Network Scanner missing TSMx unload Fixed in CDMA2000 interface EVDO Fixed problem in the protocol decoder with Connection Layer Format A packets These are now handled properly This was seen to be a problem with SLP F fragments that use Format B packets Version 12 76 05 10 2009 Fixed occational crashes access violations on heavy start stop conditions New device variant TSML GW enabled New in GSM Network Scanner Carrier to Interference measurement C I Version 12 67 02 06 2009 Fixed in WCDMA Scanner wrong MCC MNC decoding Fixed in GSM Network Scanner wrong MNC decoding for 3 digit MNC Version 12 64 15 05 2009 Fixed in ViCom RF Power Scan crash on interface release after lost connection or bad cable connection New in CDMA2000 interface 1xEvdo BCH Demodulator Release Complete demodulation and decode of synchronous control channel Following Protocol messages supported Sync Message Quick Config Message Sector Parameters Message Access Parameters Message Binary bits for message result retu
2. you can find an entry in the Control Panel of Windows and you can read out the version see dialog 9 version 11 00 0 4 in this example Link for the TSMx Device Driver Entry Start gt Settings gt Control Panel gt Add or Remove Programs ajio Sa 6 Currently installed programs I Show updates Sort by Name z Change or C N 5 Remove Programs 5 Steuer Hilfesammlung Size 13 52MB 3 Synplicity FPGA Products 8 8 0 4 Size 350 00MB B Tera Term Pro Add New y eee T T Online 6 0 Size 215 00MB Qe T Online WLAN Access Finder Size 0 88MB iB tsmw Size 6 66MB Add Remove Windows gH tsmw k1 Size 8 29MB Components E B6 Runtime Setup EN E9 vB6 Runtime Setup D Program Files Ocxsetup Size 2 404 00MB Set Program iB Vicom Size 25 76MB Access and z z 3 TS Defaults Windows Driver Package Rohde amp Schwarz TSMx Device Driver for Firewire Size 1394 12 18 2006 11 00 0 4 Click here For support information Used rarely To change this program or remove it From your computer click Change Remove JB windows Installer 3 1 KB893803 jB winecap 4 0 2 Size 0 19MB i5 Xilinx Embedded Development Kit 9 1i Size 21 02MB 0 54MB j Xilinx ISE 9 1i Size 4 285 00MB Dialog 9 Only in cases where you don t have the TSMx Device Driver for Firewire entry in the control panel an older version 10 xx is installed on the host PC The TSMx_Firewire_x pdf document pr
3. New First version of TSML W ViCom ROMES 3 60 SP 2 v10 68 New Support for TSML receiver types TSML W UMTS PN Scanner TSML G GSM Network Scanner TSML C CDMA2000 Scanner Bugfix UMTS PN Scanner Improved Suppression of intermodulation due to sophisticated PreAmp control Bugfix UMTS PN Scanner Removed error in drift calculations after long measurements ROMES 3 60 SP 1 v10 56 New R amp S_OHCI1394_InstallationTool e TSMxOptionKeylnstaller V10 63 with new Installed Option Key tab displays the expiration date for time limited options e TsmxFirmwarelnstall with new firmware version 10 63 e R amp S_OHCI1394_InstallationTool with OHCI1394 sys V10 53 0 3 Bugfix TsmuWorker dll V10 60 in combination with OHCI1394 sys V10 53 0 3 eliminates host PC freezing under certain circumstances Bugfix Cdma2000 dll bugfix in crc demodulation ROMES 3 60 v10 56 New External Trigger for CW measurements TSMU K15 New TSMx option CDMA 2000 PN Scanner TSMU K12 New Accelerator Files generally created once a time at start of measurement Acceleratorxxx hex New Updated TSMx utility tools for TSML launch e TSMxOptionKeylnstaller e TsmxFirmwarelnstall e R amp S _OHCI1394_InstallationTool New Additional synchronization info stored in R amp S ROMES measurement file cmd New TSMx related version info in R amp S ROMES help menu Help gt TSMx Installation New Application files renamed TSMU_UMTS_PNS elf gt TsmxApplication elf TSMU_BS1 elf
4. amp ROHDE amp SCHWARZ Test and Measurement Division Release Notes Revision 02 Firmware R amp S TSMU TSMU H TSMQ TSML x Radio Network Analyzer Firmware Release 12 72 These Release Notes describe the following models and options of the R amp S Radio Network Analyzer e R amp S TSMU order no 1153 6000 02 e R amp S TSMU H order no 1153 6000 03 e R amp S TSML W order no 1153 6000 11 e R amp S TSML C order no 1153 6000 12 e R amp S TSML G order no 1153 6000 13 e R amp S TSML CW order no 1153 6000 15 e R amp S TSML GW order no 1153 6000 20 e R amp S TSMQ order no 1153 6000 50 Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 Table of Contents Important Notes csscssscssccssecssccsscssessssnsesssssssesesssssssesesesssesssssssnsesssessssesenessneesesesensssnseonsesssesssessnessesseessones 4 General adak T e A a EE E i nag eres E E E a a enna de tesa aaed aes 4 TSMx Firmware GaS FAA AN A E A T A A ada ee cdoav lan febecse aes 4 Instruments with Firmware Version LO XX c cccccessessscesssssceesceecesecsecaecaecaeecaeeeseeeeeenseeaecaecaecnsecaeceesaeeestenes 4 Release Notes for R amp S ViCom Users icici siatink davis E Me E EA ERR 4 Release Notes for R amp S ROMES Users c59sscsc05 4 40 3 cbensas5setestiatondas plead ttita btt 1s btn n a triseta raant naaa t eraat arase ee raa 4 Upgrading the Instrument FirmWar
5. applications which are interfacing the instrument Reset the instrument and execute the TsmxFirmwarelnstall exe file from the program directory and a dialog box according to dialog 1 comes up Enter the serial number of the instrument 1 the label could be found on the rear panel and select the appropriate firmware version 2 Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 ER TSMx Firmware Installation from Firmware 11 xx to 12 1 S ioj x TSMx Firmware Installation from Firmware 11 xx to 12 xx 1 Determine and enter the Serial Number of your TSMx 2 Choose a Firmware to be installed 3 Close all other applications that can use the TSMx 4 Be sure only one TSMx is connected to your PC 5 Switch OFF your TSMx 6 Switch ON your TSMx 7 Wait half a minute The TSMx will appear in Windows Device Manager 8 Verify again that the state of the whole upper TSM LED line is stable for 5 seconds 9 Click the appearing Install button You must NOT interrupt the Installation after having clicked the Install button 10 After update close this Installer and manually switch OFF your TSMx 11 When switching it on again the TSMx will boot with the installed Firmware 4 2 Piwertemsbe Serial Number of your TSMx Meese cho irmware G Please choose a Firmware Dialog 1 Firmware Update Dialog Window After entering the serial number and choosing the firmware version to install the Install
6. be downloaded from the internet under http www rohde schwarz com Select DOWNLOAD and search for R amp S TSMU TSMQ TSML within the category DRIVERS 17 Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 Step 2 Step 3 Step 4 Upgrade TSMx firmware V10 xx to V11 11 with the appropriate firmware installer to version 11 11 This tool could be downloaded from the internet under http www rohde schwarz com Select DOWNLOAD and search for R amp S TSMU TSMQ TSML within the category FIRMWARE Upgrade IEEE 1394 driver version on the host to version 11 00 0 4 with the appropriate TSMxDriverInstall exe This tool could be downloaded from the internet under http www rohde schwarz com Select DOWNLOAD and search for R amp S TSMU TSMQ TSML within the category DRIVERS Wait for the TSMx device driver dialog Connecting a TSMx Receiver to Host PC after TSMx Device Driver Installation for a certain instrument before you proceed with Step 4 Upgrade TSMx firmware V11 11 to V12 37 using the appropriate firmware installer to version 12_37 This tool could be downloaded from the internet under http www rohde schwarz com Select DOWNLOAD and search for R amp S TSMU TSMQ TSML within the category FIRMWARE 18 Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 Connecting a TSMx Receiver to Host PC after TSMx Device Driver Installation After installing TSMx 1394 device driver version
7. could be used to integrate the R amp S TSMx scanner models into a customer software application ViCom is a host PC software packet which enables the control of the TSMx receiver in a customer application Dedicated TSMU K3x option keys need to be installed on the instrument to enable this feature Please refer to the internet under http Awww rohde schwarz com and search for available OEM options of your TSMx receiver model The current version of the ViCom host PC software interface could be downloaded from the internet under http www rohde schwarz com Select DOWNLOAD and search for R amp S TSMU TSMQ TSML within the category SOFTWARE Upgrading TSMx Instruments with Firmware Version 10 xx Not applicable for instruments from version 11 xx With the release of this document all TSMx receivers are shipped with firmware version 12 37 so you can neglect this section TSMx devices with firmware version 10 xx cannot be upgraded directly to firmware version 12 xx These instruments have to be brought to version 11 11 first and then in a second step to the final 12 xx version TSMx 1394 device driver version 10 53 0 3 has to be installed on the host PC temporarily to execute the upgrade to intermediate firmware version 11 11 The upgrade needs to be done in the following oder Step 1 Downgrade IEEE 1394 driver version on the host PC to version V10 53 0 3 using the R amp S_OHCI1394_InstallationTool exe This tool could
8. higher New Additional I Q Demodulator implemented New Support for ROMES software option AS6 Inband Power Measurement New Support for ROMES software option GS3 Network Scanner New Support for ROMES BCH Decoder Bugfix Boot problem with newer FPGA lots Version 08 00 New Customer options available TSMU K5 K6 K7 K8 K9 11 Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 Host PC Software related ROMES and TSMx Utilities In brackets version of distributed TSMx_Application elf File ROMES 4 30 SP 1 v12 71 New Devicekey installation mandatory for instruments New TSML GW support New Improved internal frequency synchronization New TSMxOptionKeylInstaller utility v12 72 gt mandatory for TSML GW scanners New TSMxFirmwarelnstall utility v12 72 gt for instrument upgrade to v12 72 FW v12 72 not necessary for scanner types TSMU TSMQ TSML G TSML W TSMU H TSML CW TSML C ROMES 4 11 SP 2 v12 61 Bugfix TSMU K15 CW The raw data might contain stair artifacts up to 98 dBm if the input level was higher than 50 dBm Bugfix TSMU K15 CW Single Channel Measurements meas values with detektor average are false if measurement time is 1s Bugfix TSMU K15 CW Frequencies at 650 750 MHz may lead to false measurement results due to PLL settings ROMES 4 11 SP 1 v12 55 ROMES 4 10 SP 1 v12 37 New IEEE1394 connection stability New TSMxOptionkeylnstaller updated options check New EVDO support TSM
9. 11 xx on the host PC and connecting a TSMx receiver for the first time to the IEEE1394 port the Windows New Hardware Wizard comes up and asks to connect to Windows Update for a pleasant software driver for the new hardware see dialog 5 Neglect this dialog by checking the box No not this time Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Read our privacy policy Can Windows connect to Windows Update to search for software O Yes this time only Yes now and every time connect a device ON Click Next to continue Dialog 5 Windows New Hardware Wizard Step Then a second dialog comes up see dialog 6 Confirm to update the software automatically Windows now installs the TSMx device driver for the connected TSMx The successful completion of the installation will be acknowledged The Windows Hardware Wizard once comes up for every new TSMx device connected to the IEEE1394 port or anytime you have installed the TSMx 1394 device driver before Found New Hardware Wizard ig S Welcome to the Found New ya Bape Hardware Wizard Y This wizard helps you install software for Rohde amp Schwarz TSMU If your hardware came with an installation CD lt 6 or floppy disk insert it now What do you want
10. 2 FW v12 72 supports new scanner model TSML GW Var 20 Firmware update from v12 37 not mandatory but recommended for all other TSMx scanner models Refer to section OptionKeylnstaller Utility how the check the firmware version See Upgrading the Instrument Firmware for instructions how to upgrade the instrument firmware Instruments with Firmware Version 10 xx Attention TSMx scanners with installed firmware version 10 xx on require special upgrade procedure Please carefully follow the instructions in the Upgrading TSMx Instruments with Firmware Version 10 xx section Release Notes for R amp S ViCom Users For all Vicom TSMx OEM programming interface related issues please refer to the separate ViCom release notes The notes could be downloaded from from the internet under http www rohde schwarz com Select DOWNLOAD and search for R amp S TSMU TSMQ TSML within the category SOFTWARE Release Notes for R amp S ROMES Users As the TSMx functionality and performance of ROMES options are directly related to the installed version of the R amp S ROMES software please refer to the corresponding ROMES release notes too Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 Upgrading the Instrument Firmware The tool TsmxFirmwarelnstall is used to update the instrument firmware This tool is interactive and guides you through the process of updating the instrument firmware Program Requirement
11. Firmware button at the bottom of the dialog becomes active Pressing this button launches the update procedure Important Note Please assure that you entered the get 6 digit number after the abbreviation Ser correctly before pressing the install button Serial Number Check The serial number input is being checked if it matches the serial number stored in the instrument itself In cases of a serial number mismatch a dialog comes up which indicates this failure The user can stop the update procedure at this point Please contact the R amp S support in cases of a serial number mismatch Firmware File Download If the serial number check is passed successfully the update routine proceeds automatically with downloading the firmware file A list box in the program dialog outputs each single step of the update procedure The download process is displayed with a bar at the bottom of the dialog Important Note Please do not interrupt this process with any user interaction respectively do not interrupt the TSMx power supply at this point After completion the successful firmware update is confirmed in a dialog box Program Exit Press the button exit to end the update program The instrument reboots after program exit Ensure to end this program before interfacing the TSMx with any other TSMx utility or R amp S ROMES software Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 O
12. OEM Programming Interface ViCom cceccescceseessceseceseccecseecseeeseeeaeeeeeeenseecsaecsaecseecaeeeaeeneeeeeeeereneees 17 Upgrading TSMx Instruments with Firmware Version 1O XX ccccecccsseesseeseeeeeeeseeeeceaecseecaeecaeeeaeeneeeeeeeeeenrees 17 Connecting a TSMx Receiver to Host PC after TSMx Device Driver Installation 0 cc eceeeceeeeeceteereeeeeeees 19 How to Reorder TSMx Firmware Options c ccsccesesseessceseeeseceecaeecseeeseeeaeseeeeceneeesaecsaecaeecaeeeneeeeeseeesereneeees 21 How to Check Installed TSMx 1394 Driver Version cccesccssessseceseeseeeseeeseeeeeeeeceseecaeceeecaeecaeeeaeeneeeeeeeesenarens 22 Problems atter Firmware Update sssi tnea e rarae vetebeaguaneetebovesnsvasiedbis E Ea EO EERE EN EREA 23 Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 Important Notes General In this document the R amp S product series R amp S TSMU R amp S TSMU H R amp S TSML x and R amp S TSMQ are generally abbreviated as TSMx Unless explicitly noted the abbreviation TSMx is valid for all models in this series IEEE1394 TSMx Driver v 11 0 0 6 TSMx IEEE1394 driver version v11 0 0 6 mandatory for interfacing scanner model TSML GW Var 20 with ViCom and ROMES software or with TSMx utilities TSMxFirmwarelnstall and TSMxOptionkeyinstaller See How to Check Installed TSMx 1394 Driver Version for details how to verify the installed TSMx 1394 device driver version TSMx Firmware Update to v12 7
13. SML W 900011 selected Dialog3 TSMx Options Property Page Missing Device Key Installation The utility displays the current state of the device key installation The highlighted text No Device Key has been found in dialog 4 comes only up if no valid Device Key is installed on a instrument A valid Device Key is a precondition for installing Option Keys properly and is normally installed at factory site Only for 1 generation instruments had been shipped without a installed Device Key Please contact your local R amp S service representative if no Device Key has been found on a instrument Sa TSMx Option Key Installer Version 11 16 0 0 expertmode a 5l a ioj xj Disconnect T5Mx Select TSMx Tsmi w 900011 S4 Exit TSMx Options TSMx Info Install Option Files Get Device ID File No Device Key has been found Available Options Installed Option Keys Expert Functions No Option Keys are installed MISSING KEY Kil namo IH i Dialog 4 Missing Device Key Installation Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 Read Out the Device ID File TSMx firmware options are based on the instrument specific Device ID File The ID File is unique for every instrument and has to be submitted if the customer places a reorder for a specific TSMx firmware option Use the Get Device ID File button in the TSMx Options property page to download the Device ID File and to
14. U K12 ROMES 3NG Rev1 SP 6 v12 34 New IEEE1394 connection stability Bugfix ST 1 2 4 Demodulation for GSM ROMES 3NG Rev1 SP 5 v12 21 New Configurable PPS edge for GPS synchronization Bugfix TSMx hang up after 36 minutes STB Bugfix TSMU K15 attenuator decrement after one second Bugfix GSM Demodulator stops for requested Sys Type demodulation Bugfix UMTS Demodulator deltes BTS at channel failed ROMES 3NG Rev 1 SP 4 v12 09 New RS232 Tunneling New RS232 Silent Mode Bugfix Halt of GSM Sync while measurements ROMES 3NG Rev 1 SP 3 v12 03 New First version of GSM Demodulator New First version of C2K Demodulator ROMES 3NG Rev 1 SP 2 v11 22 New Optionkeylnstaller Warning if keys are missing Bugfix Option handling RF Power Scan TSMU K17 12 Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 Bugfix Demodulator tasks with maximum attenuation ROMES 3NG Rev 1 v11 04 New Support for Windows compliant TSMx device driver V 11 00 0 4 or higher New ROMES option handling via TSML x New Release of TSMQ New TSMU K17 K37 RF Power Scan Bugfix Improved software stability after connection lost situations to the TSMx receiver ROMES TSMx measurement can now be stopped ordinary and restarted in such situations Bugfix WCDMA measurements synchronization problems for code groups 8 46 59 63 in High Speed mode removed ROMES 3 60 SP 4 v10 72 New Support for TSML CW receiver up to 6GHz
15. ation messages can now be requested for types 1 2 2bis 2quater 2ter 2n 3 4 5 5bis Ster 6 7 8 9 13 13alt 15 16 17 18 19 20 The messages are delivered as byte stream An additional new function can decode the messages into text form New in the CDMA2000 Scanner interface BCH demodulation Layer 3 Decoding EVDO Scanning 15 Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 for TSMU and TSMM maximum number of channels extended from 12 to 18 New user defined message handling described in manual chapter Debugging and Error Handling 16 Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 Notes for R amp S TSMx Users TSMx Firmware Options Option Key Licensing Starting with R amp S ROMES V3 52 enabling TSMx firmware options requires the installation of dedicated option keys on the instrument The licensing via the TSMx application file elf had been stopped Reordered licenses for TSMx firmware options are shipped on a CD ROM TSMx Option File and the customer needs to install the xml based option key s using the TSMxOptionKeyinstaller utility Note Please keep in mind that enabling TSMx firmware options TSMU K1x for R amp S ROMES software requires the appropriate license option file on the ROMES software too Please contact your local R amp S sales representative for questions on this matter TSMx OEM Programming Interface ViCom The ViCom programming interface
16. ce release Fixed occasional TSMx connection loss on the start of a measurement while other measurement types are still running Fixed Somtimes the receiver was disabled and measurements have been delayed for up to 40sec Fixed in WCDMA Scanner GSM Network Scanner CDMA2000 Scanner occasional crash on the start of measurement of multiple interfaces at the same time Fixed in CDMA2000 Scanner occasional crash on interface release Report of inband power corrected This was somtimes invalid when no CIR was measured PN Code shifted for 15 PN chips gt less standarddeviation for RSCP and Ec lo New interface for CW measurement New TCXO synchronisation improved PPS synchronisation will be used earlier when GSM Sync gives changing values New in CDMA2000 Scanner supported channel count is extended from 18 to 32 CDMA2000 and EVDO New in WCDMA Scanner supported channel count is extended from 12 to 32 Version 12 41 25 07 2008 Fixed in the CDMA2000 Scanner all frequencies with odd kHz number have been interpreted as EVDO Frequencies with 1 kHz offset was workaround for EVDO Tests Version 12 39 30 06 2008 Fixed for TSMx Driver Installation Windows XP SP3 was not supported Fixed with TSMx Firmware 12 37 IEEE1394 connection stability issues Fixed in GSM NWS crash of measurements with TCH on Pentium Ill New in the GSM Network Scanner interface bTotalPowerOffsetInDB10 Demodulation of GSM System Inform
17. copy it into a local directory on the PC The file name contents the serial number and model type and the file extension is hex E g Devid_TSML W_100011 hex This file needs to be attached with the TSMx option order Installing TSMx Firmware Options Reordered TSMx firmware options are shipped on a CD ROM TSMx Option File The included TSMx Option Keys need to be installed on the instrument to enable the firmware option s Select the TSMx Option property page and click on Install Option Files Select in the upcoming file dialog the storage location of the Option Key s The keys are located in the CD ROM directory OptionKeys Select any xml file in this directory and the tool will automatically install all the included and valid Option Keys of this directory The Available Options page shows all the enabled TSMx options on a single instrument and will be updated with the new option if the key could be installed successfully Program Exit Disconnect Press the Exit button to disconnect from any connected receiver and to end the TSMxOptionKeylnstaller utility Press the Disconnect TSMx button to disconnect from connected TSMx instruments and to free them for connection with another utility respectively software application without ending the TSMxOptionKeylnstaller utility Troubleshooting Log Messages Window In cases where the connection to the instrument fails or there are troubles to insta
18. e seesessesseseseoeseeeerseeoeseeeerseecesoreeeeorsereorseeoeseeeeesoesereoesoreereorsereorseeoesereeeeoeeeres 5 Program Requirement issen aa E a E E EEEa bes EEA E EEE a 5 Program Sources Program Installation se eeeseeeesseeeeseeeessrseessessesessteressteresstsetsteseestesesetsesseeressesessesetseseene 5 PLOSTAM Staion a a a chess oe unread hae ausnesh a AE At ebeaet ves A A Meera aory 5 SerialNumber Check x tesissctsee cesses ane Matias Search iki a A Oe ies eat At a a ech hohe reat resect 6 Birmiwate File Do winl6ad itis ssaccoss ye tres e ike ahs ech iansae enna en Mal boet eee 6 Program Exite a R Sesh gered Roe tiat hn ces escak e Rota ae GRA eee eee 6 OptionKeylnstaller Utility c c cccccessecssccesescevesnossecsscsnsevesoucsusssseseteessecueotesevesnescunnes SEEVE ro SE sosevessosdecbecdenesebeasess 7 Generalene n ARER E ie RRRA tee ite ia E eee I RA E ead eee Deegan eS 7 Program Requirements nesir See Sees Senden ide EE duc ee dea dle dae deals esccbad T E a a 7 Program Sources Program Installation cccccceescesscsssessceesceecesecesecaecseecseecaeeeseeeaeceseceaecaecaecaecneeceeeeeeaeeass 7 Propran Staiosin i eE E E RE EEEE AEREE REO E EERE bag vee w ona Ona eed eae 7 Auto Detection of Connected TSMX Devices cccccescesssessesseeescessceecesecaecaecacecseecaeeeeenseceseceaecnaecaeceeeneeeneeaes 7 Implicit Firmware Upgrade while Auto Detection cccccescceseesecesecesecesecacecseeeseeeeecesecaecaecsaecnaeca
19. e up please contact the R amp S support Background There are two configuration directories stored on the Flash Card of each instrument HO1V10B0 and HOOV10B0 and the xilinx sys file defines which one is currently active Two Different configuration directories are necessary because the Controller PCB inside the TSMx has been manufactured in two different revisions and each revsion utilizes its own configuration Under certain circumstances it is possible that xilinx sys file enables the wrong configuration directory As a consequence the unit doesn t come up 23
20. ecaeesaeeeneeaes 8 TSMx System Information s mese doce deveed en scktei carck gas Rast seas ce sk ges ash oes as Seed cade sed con NED Tees SGA eh wae 8 TPSMx Option nformati Hse cascs decd seh sed cones Rack oak feast eee veh deeb eg hoes Ant edeah Hel GRA ATs eda eho 9 Missing Device Key Installation sssrinin ae bas hast a Raa oes ars Seeds sed oA OE Ses GA oh neh 9 Read Out the Device ID Pile sss c sihgh seh csiaeidhs hadhbes Aavceeel ea oe a EE Anse ne ed oh E a R ei aes 10 Installing TSMx Firmware Options ecinda eis cas actos beaten sud nash R E eE e 10 Program Exit Disconnect zeeer eenn bed onc Ra eae oes asst ce de aches ahd A eS a ante eis 10 Troubleshooting Log Messages Window csccssccesessssesscesecsecenecseecseeeseeeneeseesaeenseecsaecaaecaeecaeeeneeneeeneeserenarees 10 Modifications in Current Version and History ssccscsscssscsssssscsssscssccsessssssssssscsesssssssssessecsssnsesssessssesees 11 Instrument Firmware related cc EE EEE EEEE T EEE T 11 Host PC Software related ROMES and TSMx Utilities 2 0 ceccececsseesseeseeeseeeseeeeceseceeecaeecaeeenseneeeeeeeerenrens 12 Host PC Software related ViComi vs nnua ia peti Shasta aicisese E ornate 13 Notes f r R amp S TSMY USES si isiccsssccseassoseusdivsceevessnsessasenents ssunsdasveesvessodans do0ncesaassateosdeed euvocesasse sunsdaonee ss eSsesaes sovbecees 17 TSMx Firmware Options a rrr arar aera E aa a E eae aanas tess a NEE sd oeae VEE homed eee 17 TSMx
21. for Copy to Cipboard Trying TSMx connection Firmware 11 02 or higher required R amp S Device Driver for TSMx loaded 1394 driver version 11 0 0 4 1394 DLL version 11 0 0 4 count of connected TSMx 2 TSML W Serial Number 900011 TSMU Serial Number 100410 TSM 1011 selected Dialog2 TSMx Info Property Page Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 TSMx Option Information Pressing the TSMx Options tab lists all the enabled firmware options within the Available Options tab 2 and indicates if a valid Device Key 1 is installed on that instrument see dialog 3 Selecting the Installed Option Keys tab shows all the installed option keys for that instrument Time limited keys are listed with its expiration date 2 TSMx Option Key Installer Version 12 36 0 0 8j ioj x Disconnect T5Mx Select TMx Ts5mL w 900011 x Exit TSMx Options TSM Info Install Option Files Get Device ID File ROMES WCDMA PNS ROMES WCDMA BCH Demod ROMES RF Power Scan OEM iCom WCDMA PNS OEM ViCom WCDMA BCH Demod OEM ViCom RF Power Scan Sevelopment Option Log Messages Click right mouse button for Copy to Clipboard Trying TSMx connection Firmware 11 02 or higher required R amp S Device Driver for TSMx loaded 1394 driver version 11 0 0 4 1394 DLL version 11 0 0 4 count of connected TSMx 2 TSML W Serial Number 900011 TSMU Serial Number 100410 T
22. ll Option Keys the Log Messages window is a valuable tool for service and customer support to localize a problem This window outputs text messages and offers the possibility like the other text boxes too to post its contents via context menu into to Clipboard or into a text file and to provide this with the problem report Simply right click on the mouse in the Log Messages Area or any other list box and select where you want to copy the text 10 Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 Modifications in Current Version and History Instrument Firmware related Version 12 72 New TSML GW support Version 12 37 New IEEE1394 connection stability Version 12 04 New RS232 support New RS232 silent mode New PPS edge configurable Bugfix Rare TSMx hangup after about 36 minutes standby Version 11 11 New Only minor changes for production performance and behavior equal with version 11 04 Version 11 04 New Mandatory for Windows compatible device driver V11 00 0 4 or higher Version 10 63 Bugfix BIOS boot bug in some notebooks which require a 1394 configuration ROM on each device Version 10 24 New Mandatory for ROMES 3 52 and newer New Released with ROMES V3 51 Rev 1 New Instrument returns extended version info New Enlarged memory for application programs New Improved Performance Test Bugfix Noise radiation via antenna in Stand By Mode eliminated Version 10 00 New Mandatory for ROMES 3 50 and
23. ovides a general overview of the TSMx 1394 interface and how to migrate between the different versions Please refer to this documentation for details This document could be downloaded from the internet under http www rohde schwarz com Select DOWNLOAD and search for R amp S TSMU TSMQ TSML within the category MANUAL 22 Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 Problems after Firmware Update Problem The instrument doesn t come up after firmware update and indicates Flash Card Error most of the time the reason is a discrepancy between the hardware version of the Controller PCB inside the unit and the activated configuration directory on the TSMx Compact Flash Card In such a case it is possible to correct this mismatch in the configuration directory manually on a PC with Compact Flash card slot respectively Compact Flash card reader Solve the configuration problem manually For that purpose remove the Flash Card from the instrument cf Operating Manual for details and insert the card into the PC Card reader or PCMCIA slot of a PC notebook Open the xilinx sys file in the root of Flash Card with an editor and change the dir variable according to the following table Content before Modification Content after Modification dir HO1V10B0 gt dir HOOV10B0 dir HOOV10B0 gt dir HO1V10B0 The unit should come up after insertion of the reedited Flash Card If it doesn t com
24. ptionKeylnstaller Utility General The TSMxOptionKeylnstaller utility is a program to recall the TSMx device setup and to install TSMx firmware options Program Requirements gt R amp S TSMx IEEE1394 device driver on the host PC from version 11 00 0 4 installed see How to Check Installed TSMx 1394 Driver Version gt Host PC and TSMx connected via the IEEE1394 cable gt RS232 interface of host PC and TSMx connected via a null modem cable gt Terminal program started Terminal Settings Baudr 115200 Data 8bit no Parity Stop 1bit no HW handshake gt TSMx powered up Important Note For instruments with firmware versions 10 xx see Upgrading TSMx Instruments with Firmware Version 10 xx for details Program Sources Program Installation There are various sources for this tool The latest version of the TSMxOptionKeylnstaller utility could be downloaded from the internet under http www rohde schwarz com Select DOWNLOAD and search for R amp S TSMU TSMQ TSML within the category SOFTWARE Unpack this zip files into a local directory on the hard disc drive and proceed with the Program Start section This tool is also provided with the ROMES CD ROM respectively Tsmx Option File CD ROM gt Firmware amp Drivers R amp S RF Receivers TSMx TSMxOptionKeylnstaller and on the TSMx CD ROM respectively TSMx Option File CD ROM gt TSMxOptonKeylnstaller The TSMxOptionKeylInstaller prog
25. ram could be started directly from the CD ROM drive by running the executable file gt see Program Start section Program Start Assure that no other program interfaces the TSMx at the same time Close all the other applications which are interfacing the instrument Reset the instrument and start the TsmxOptionKeylnstaller exe in the program directory Auto Detection of Connected TSMx Devices After start the utility will automatically detect any connected TSMx device This process could be monitored on the Log Messages box at the bottom of the dialog window The Select TSMx list box on top of the dialog window will list all the detected TSMx device s with its individual model variant and serial number Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 In configurations where more than one TSMx instrument are connected select the appropriate instrument from the list box In cases where no instrument is being detected automatically the connection could be initiated manually by pressing Connect TSMx button No TSMx device is being detected If the manual connection fails even a TSMx device is connected the wiring and the power supply should be verified Reset the instrument via Reset button on the front panel or by removing the power plug on the rear panel and try to connect again If this problem persists please proceed with the trouble shouting section in the user manual Implicit Firmware Upgrade while Auto Detec
26. rn to host Protocol Type provide for each messag result SLP F fragmentation supported support for EVDO Layer 3 decoding New in CW support for device variants TSML G TSML C TSML W changed in GSM Network Scanner Layer 3 decoder output format has been changed changed in WCDMA Scanner Layer 3 decoder output format has been changed Version 12 55 12 01 2009 Fixed occasional crash on interface release Fixed in CW occasional hang up of TSMx on measurement restart rare hang up of TSMx during measurements Single Channel Measurements meas values with detektor average are false if meastime is 1s rarely the meas values of noise are significant smaller than the expected noise Frequencies at 650 750MHz may lead to false meas results due to PLL settings Fixed error handling when trying EV DO demodulation New in CW 14 Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 IF overflow detection CViComCWinterfaceData SMeasResult SPowerResult bAdcOverflow must be evaluated optional fix attenuation optional external trigger New multi instance interfaces for CDMA2000 GSMNWS UMTSPNS Version 12 52 06 11 2008 Fixed Support for crash report If PhylisCrashReport dll is available a file RuSModulePool_dd mm yyyy_hh mm ss zip is generated in the LogFiles directory when the application crashes Fixed occasional crash while loading an interface Fixed occasional crash on interfa
27. s The TsmxFirmwarelnstall program has the following requirements gt PC notebook with IEEE1394 interface and TSMx connected gt PC notebook with RS232 interface COM1 and TSMx connected via a null modem cable gt Terminal Session started Terminal Settings Baudr 115200 Data 8bit no Parity Stop 1bit no HW handshake gt R amp S TSMx IEEE1394 driver from V11 00 0 4 installed see How to Check Installed TSMx 1394 Driver Version gt TSMx powered up and Power On sequence passed see the manual for details PROCESS STATE and RUN LED stable off for at least 10 sec Program Sources Program Installation There are various sources for this tool The latest version could be downloaded from the internet under http www rohde schwarz com as a zip file Select DOWNLOAD and search for R amp S TSMU TSMQ TSML within the category FIRMWARE Unpack this zip files into a local directory on the hard disc drive and proceed with the Program Start section This tool is also provided with the ROMES CD ROM gt Firmware amp Drivers R amp S RF Receivers TSMx T SMxFirmwarelnstall and with the TSMx CD ROM respectively TSMx Option File CD ROM gt TSMxFirmwarelnstall The firmware install program could be started directly from the CD ROM drive by running the executable file gt see Program Start section Program Start Assure that no other program interfaces the TSMx at the same time Close all the other
28. the wizard to do Dialog 6 Windows New Hardware Wizard Step II 19 Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 a Please wait while the wizard searches Sa Rohde amp Schwarz TSML W Dialog 7 Windows New Hardware Wizard Step Ill Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for Rohde amp Schwarz TSML W Click Finish to close the wizard lt Back T a Cancel Dialog 8 Windows New Hardware Wizard Step IV 20 Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 How to Reorder TSMx Firmware Options 1 2 Search in the internet under http www rohde schwarz com for a specific TSMx model and check under Options the available options for a certain TSMx model Download the device specific Device ID File from the instrument using the OptionKeylnstaller utility and submit this file with the TSMx option order see Read Out the Device ID File In return you will get a TSMx Option File CD ROM with the necessary option keys This option key file s needs to be installed on that instrument by using the TSMxOpitonKeylnstaller utility Installing TSMx Firmware Options 21 Release Notes R amp S TSMU TSMQ TSML x TSMU H V12 72 How to Check Installed TSMx 1394 Driver Version In any case a valid driver version 11 xx of the TSMx 1394 device driver is installed on the host PC
29. tion While detecting connected TSMx devices the program checks whether the firmware needs to be updated Only for instruments with older firmware revisions the tool automatically offers the firmware upgrade For the others this step will be passed without any user interaction Even if it s not recommended the firmware update can be neglected The successful firmware upgrade will be acknowledged TSMx System Information Initially after connecting to the instrument the utility displays the TSMx Info property page This page gives an overview of the system information of the selected instrument The following items are being displayed Hardware revision of assembled PCB s 1 Device serial numbers 2 Firmware version 3 Calibration date 4 2h 2101 x Disconnect TSMx Select TSMx Tsmi w 900011 x ER TSMx Options TSMx Info Click right mouse button for Copy to Clipboard Input Power Normal JTag Devices ACE V2Pro Counter IEEE 1394 Chip Revision 0x61 TSMx Flash 900011 TSMx EProm 900011 Receiver Flash 900011 Receiver EProm 900011 wmeware version 12 37 Virtex2Pro Version HO1V1280 Thu Sep 13 20 31 08 2007 Application Version 12 34 0000 Thu Jun 05 14 59 02 2008 Firewire Loader Version 12 37 0000 215672 byte Flash Loader Version 12 04 0000 56856 byte abr ation IF Fiter Version 257 at 43 C Mon Dec 18 09 46 50 2006 Log Messages Click right mouse button

Download Pdf Manuals