Home
SMEG Ultrasonic Cleaner
Contents
1. Monitor the cleaning process Check the cleaning result by visual inspection Repeat the cleaning process if necessary Rinse the cleaned items after the cleaning and dry if necessary 10 Maintenance Care Repair Caution Pull the mains plug before you carry out any maintenance and care works Do not put the unit under water For repair return the unit to your supplier or to the manufacturer Electrical safety Regularly check the housing and the mains cable for damage to avoid electrical accidents Care of transducer tank Lime deposits in the stainless steel tank can be removed gently by an appropriate cleaning detergent operate the unit with water concentrate Do not use any scouring media Care of housing Depending on their kind contaminations can be removed with a mild household cleaner or decalcifier wipe with wet cloth Disinfection If the unit is operated in the medical and sanitary sector it is necessary to disinfect the transducer tank and the surfaces regularly for hygienic purposes standard surface disinfectants SMEG VU GB Revo T 033 SITI C 11 Putting out of operation and waste disposal The unit and its components can be taken to metal and electronics recycling stations or returned to the manufacturer 12 Manufacturer s contact address Via L da Vinci 4 42016 Guastalla RE Italy Tel 39 0 522 821 1 Fax 39 0 522 821 592 instruments smeg it www smeg instruments com SME
2. SMEG Ultrasonic Cleaner USER MANUAL smeg INSTRUMENTS English 1 Safety warnings Carefully read the safety warnings before you operate the unit BbbbbDBb bb The present ultrasonic cleaning unit has been designed for the ultrasonic treatment of items and liquids only The unit must be operated by instructed staff observe and follow the operating instructions Risk of electrocution Connect the unit to a grounded shock proof socket only Do not open the unit Opening of the unit by specialized staff only For operation place the unit on a dry and stable work place Do not immerse or rinse the unit with water Pull the mains plug in case of any malfunctions if humidity might have entered the unit inside for maintenance purposes and after use Risk of fire and explosion Do not operate the unit with flammable cleaning media Risk of damage to the transducer tank Do not put any acids HCI etc or chlorides into the stainless steel tank Do not place any items directly on the tank floor Risk of burning and scalding Tank housing and cleaning liquid can heat up considerably particularly if operated with heating In permanent operating mode temperatures exceeding 80 can be reached Avoid sound transmission to the operating staff Do not reach inside the cleaning liquid or touch sound carrying parts tank basket cleaning items etc during operation Noise emission Ultrasonic units can produc
3. max W 320 600 1200 1200 1600 3200 English Weight approx kg 3 3 9 1 8 0 11 0 25 0 42 0 Heating power W 200 400 800 1200 1600 2000 SMEG Ultrasonic cleaning units are in compliance with the CE marking criteria according to the EMC directive 89 336 EEC and the low voltage directive 73 23 EEC The declaration of conformity is available from the manufacturer SMEG_VU_GB_Rev0 INSTRUMENTS English 6 Unit description gt Operating panel for controlling the unit functions Transducer tank marking on the tank wall indicating the optimum filling level O Plastic carrying handles for the safe transportation of the unit Turning knob liquid drain Position D1 drain shut position D2 drain open E Turning knob temperature Temperature range 30 80 variable in 5 step s F LED indicator temperature red during heating up green when set temperature is reached or exceeded Turning knob cleaning time Possible settings short term operation 1 2 3 4 5 10 15 20 25 30 min permanent operation for continuous G operation The unit switches off automatically after 12 hours permanent operation H LED indicator for remaining cleaning time on off key for switching the unit on and off on off LED Key for ultrasonic operation and temperature controlled ultrasonic operation Ultraschall LED L Key for Degas function manual and Auto Degas
4. G_VU_GB_Rev0 English Subject to technical or visual modifications SMEG S p A Via Circonvallazione Nord 36 42016 Guastalla RE Tel 39 0 522 821 1 Fax 39 0 522 821 592 e mail instruments smeg it internet www smeg instruments com
5. Ultrasound starts operating in sweep mode Sweep function stops Ultrasound continues operation in standard operating mode Ultrasound operates in degas mode Degas function stops Ultrasound continues in standard operating mode Ultrasound operates in Auto Degas mode for 10 minutes and then switches off automatically Ultrasound operates in boost mode Ultrasound continues operation in standard mode smeg INSTRUMENTS English 9 Cleaning process A ES Ed E e Observe the general safety warnings The operator is responsible for the control of the cleaning result Take the warming of the cleaning liquid into consideration when cleaning temperature sensitive items Ultrasound can damage sensitive surfaces when operated over a prolonged period of time and particularly when operated at low cleaning frequencies If necessary for the cleaning task at hand pre heat the liquid in units with heating When the cleaning liquid has been freshly mixed switch on the Degas Auto Degas function for degassing the liquid approx 10 min Immerse the cleaning items into the cleaning liquid Do not place any items or containers directly onto the tank floor Use either a cleaning basket a beaker filled with water cleaning chemical or hang the items into the liquid Set the cleaning time switch on the ultrasound If required switch on the sweep function for the intensive cleaning of large items and for robust surfaces
6. e annoying sounds Wear personal ear protection devices when working close to an ultrasonic unit which is operated without cover Emission data for operation with cover lt 7OdBAU Exclusion of liability The manufacturer cannot be held liable for damages on persons equipment or cleaning items caused by improper use and non observance of the Operating Instructions The operator is responsible for the instruction of the operating staff For any queries please contact your supplier or the manufacturer SMEG VU GB Revo 1 INSTRUMENTS English 2 Product features m Transducer tank made of cavitation proof stainless steel m Housing made of stainless steel easy to keep hygienically clean m Sandwich performance transducer systems m Sweep function for the perfect sound field distribution in the cleaning liquid Degas function for the efficient degassing of the cleaning liquid and for special laboratory applications m Auto Degas function for an automatic degassing cycle e g after freshly mixed cleaning liquid has been filled m Quick drain on the unit back m Heating safe to run dry m emperature controlled ultrasound Cleaning process starts automatically when preset temperature is reached The cleaning liquid is stirred regularly during heating up allowing a uniform temperature in the bath m Mains cable pluggable m Electronic turning knobs m Indication of remaining cleaning time via diodes m Splashwater pro
7. for the efficient degassing of the cleaning liquid K Key for Sweep function for the perfect sound field distribution in the cleaning liquid Sweep LED N Key for Boost function for an additional increase of the ultrasonic power by approx 25 Boost LED E D on units with heating SMEG VU GB Revo 4 English 7 1 How to mount the drain duct tube socket Unscrew the closing plug A turn anti clockwise INSTRUMENTS 7 Initial operation Putting into operation Connect mains input socket C to a grounded shock proof socket with the mains cable included in delivery volume D The mains voltage must correspond with the voltage indicated on the nameplate of the unit 1 Fill the transducer tank up to 2 3 or up to the marking on the tank wall with water E Caution Do not use any solvents or acids Add a suitable cleaning chemical for the concentration follow the instructions on the label Recommended cleaners SMEG Cleaning detergents F SMEG VU GB Revo 5 smeg INSTRUMENTS 8 Operation Intended action Gerat einschalten Gerat ausschalten Start ultrasound now Switch on ultrasound temperature controlled with revolution of cleaning liquid only possible on units with heating as long as the set temperature gt actual temperature Stop ultrasonic operation by hand Switch on heating Switch off heating by hand Switch on Sweep function Switch off Sweep functi
8. of operating panel m Plastic carrying handles m Automatic switch off after 12 h operation if no keys have been activated in this period to prevent unintended permanent operation m Boost function for a power increase of the ultrasound by approx 25 on units with heating 3 Delivery volume SMEG VU Ultrasonic cleaning unit m Mains cable m Drain tube socket m Operating Instructions SMEG VU GB Revo 2 4 Technical Details Max tank volume approx litre VUO3H VUOG6H VU13H VU30H VU45H VU90H VUO3H VUOG6H VU13H VU30H VU45H VU90H 5 CE Konformitat INSTRUMENTS smeg 2 0 5 75 12 20 28 00 45 00 90 00 Mains voltage variants Vac 100 120 220 240 100 120 220 240 100 120 220 240 100 120 220 240 200 240 200 240 Tank service volume approx Litre 1 9 4 3 9 0 20 6 35 0 75 0 Ultrasonic frequency KHz 38 38 38 38 38 38 Tank internal dimensions WxDxH approx mm 240x137x100 300x151x150 310x225x175 505x300x200 500x300x300 600x500x300 Power consumption total W 280 990 1500 1500 2000 2800 Unit external dimensions WxDxH approx mm 300x179x214 365x186x264 423x274x300 568x340x321 615x370x467 715x570x467 Ultrasonic power effective W 80 150 300 300 400 800 Basket internal dimensions WxDxH approx mm 198x106x50 255x115x75 285x190x80 455x250x115 455x270x194 545x450x250 Ultrasonic peak
9. on Switch on Degas function Switch off Degas funcion Switch on Auto Degas function Switch on Boost function Switch off Boost function 1 What to do Taste on off I drucken Set required cleaning time at turning knob for cleaning time G Press m key for ultrasonic operation K Set required cleaning time at turning kob for cleaning time G Set required temperature at turning knob for cleaning temperature E Keep gt key K pressed gt 2 sec Turn knob for cleaning time G to 0 or press gt m key K Set required temperature E Turn set temperature E to 0 position Set required cleaning time G Press gt m key K Press sweep key M Press sweep key M Set required cleaning time G Press gt m key K Press degas key L Press degas key L Keep degas key L pressed gt 2 sec Set required cleaning time G Press gt m key K Keep boost key N Press boost key N on units with heating Sweep Degas Boost cannot be operated at the same time SMEG_VU_GB_Rev0 English Result Unit is ready for operation unit is switched off Ultrasound starts operating Heating starts operating Ultrasound is switched on in intervals automatic revolution of the liquid As soon as the set temperature is reached the ultrasonic operation is automatically started Set cleaning time starts running Ultrasound stops Heating starts operating Heating stops
Download Pdf Manuals
Related Search
Related Contents
GE RailConnect EMS User's Manual Digital Broadcaster Version 3.4 User Manual – Utilities ECL-246 - コイズミファニテック EX-20EF5 の取扱説明書を見る Diagnostic et propositions pour le département Office 2007 - West Point Tunturi Go Run 10_20140330.indd Samsung ML-1865W User Manual TREND 90 Movistar One Copyright © All rights reserved.
Failed to retrieve file