1. Global Presets Menu Press any menu title button at any time resets Name resets to escape without making changes Cunass igne Cunass ianed Cunass lanedl To get here from the Main Menu Security Az press CEA a e Presets Cunass igned Cunass ianed Displayed information may vary depending upon system model options and setup Cunass ianed Eunass aned Instruction message appears here gt Use option selections with buttons gt Figure 3 6 Global Presets menu The 32 possible Global Preset numbers are displayed with their given names The selected Preset is highlighted in the center of the screen Use the speed knob to scroll through the selections Each of the three options at the bottom of the screen will bring up an appropriate menu Presets Edit Preset Save Activate Preset To review or edit press Save This menu allows the au Presets name of the selected preset to be changed The knob symbol appears over the preset name Use the knob to Select Preset display the desired character and then press the 4 gt iad I Recall buttons to step to the next position and change that gt KIN Step to position o character etc Use the Caps button to toggle the letter O 5 elect character between upper and lower case The instruction message is Enter Name Take ESC to Execute Abort Press Take Take when finished Warning Recall Tane To activate the selected Pres
2. e The master password to be used for emergencies is 1000 3 15 Matrix 3200 6400 Series Switchers FPC 1000 User s Manual Extron Chapter 3 Using the FPC 1000 Front Panel Controller Misc Menu Resets Press any menu title Tair j Audio button at any time Reset Susten a Sue tere to escape without making changes To get here from the Main Menu Aroa r PPP press Room Presets e Misc e System Resets Current Ties Mute Settings FGE Delays Audio Levels Factory Default Instruction message appears here gt Use option selections with buttons gt Figure 3 15 Misc System Reset menu shown with Factory Default selected The items that appear in this menu may not be the same on your system If an item is missing it is because your system does not have the related feature For example if there is no audio module Audio Gain will not appear Select the functions to reset from the following items Global Presets Reset all global presets including given names System Reset LJ Misc Room Presets gt Select item Reset all room presets including given names System Reset E tax Current Ties Select function Reset break all I O ties Global Presets Room Presets Spits tae occ oe en Current Ties Mute Settings vute a iad Turn all mutes off RGB and or audio if these are part of this system Audio Gain if audio DE Factory D efaults RGB Delays Take Set all output delays
3. None of these options affects the operation of the FPC 1000 or the system Terminal This mode allows the LCD display to monitor RS 232 activity See Page 3 17 for an example Remote Pressing this button displays a table of information for each remote keypad or panel MKP 1000 or MCP 1000 See Page 3 18 for an example FPC This button displays an image of an FPC panel With the panel image displayed press any button or turn the speed knob to see that the corresponding object responds This allows each panel button and the speed knob to be tested To exit press any two buttons at the same time Extron Matrix 3200 6400 Series Switchers FPC 1000 User s Manual 3 4 Using the FPC 1000 Front Panel Controller Chapter 3 1 O Menu by Output Press any menu title button at any time to escape without making changes To get here from the Main Menu press e VO Displays vary depending upon system model and options Instruction message appears here gt Use option selections with buttons gt cam Mute l 64h Ol RGB 23 Audio agile A Can l Rooma A 10 miS 10 4 Canm tl Roon z Conf Room Hd A ea 02 ed 10 A 03 A 10 35 4044 35 oz Kasy os oe Selec E An to Edit Break Away Ho connect Pending change Figure 3 5 I O menu for a system with both video RGB and audio 1 0 Making Ties Mio Select output E Irneut Select input Take L Th
4. Select delay time Take Other choices Default 0 seconds loka 1 set all the same 5 4 4 zis J E Ea Lz Ll o Judd ld y a LA y Li Ll Da As explained on Page 3 9 the 3200 6400 Wideband Matrix systems have Triple Action Switching The Delay menu displays the delay time settings for each output The delay time can be set for from 0 to 5 seconds in steps of 0 5 second Use the scroll buttons 4 gt or the speed knob to select the output to be adjusted Adjust Press Adjust to change the delay time for the selected output Use the scroll buttons 4 p gt or the speed knob to adjust the delay time for the selected output and then press one of the buttons described below or press ESC to go back Take Press Take to save the changes or ESC to exit without saving changes Global This button sets the delay values for all outputs to be the same as the one selected For example you may select an output adjust its delay for 1 5 seconds and press Global All output delays will be 1 5 seconds Default This button resets all output delays to a delay time of 0 0 seconds This is also the factory default After pressing Take Global or Default a warning message appears to confirm the action Press Take again to accept the changes Extron Matrix 3200 6400 Series Switchers FPC 1000 User s Manual 3 10 Using the FPC 1000 Front Panel Controller Chapter 3 A V Mute Menu Press
5. User s Manual 3 14 Using the FPC 1000 Front Panel Controller Chapter 3 Misc Menu Security Press any menu title statusz tudio erPassyorda button at any time to escape without making changes To get here from the Main Menu press e Misc e Security Lockout Executive Mode FPE Lock Out Mode Set Pas uord Instruction message appears here gt Use option selections with buttons gt Figure 3 14 Misc Security menu shown with Normal Mode selected Security Lockout The menu shown above comes up after selecting Security Lockout from the Misc Menu on Page 3 13 after the correct password has been entered Use the scroll buttons or the speed knob to select one of the four options from this menu This example shows Normal Mode Press Take to display the menu Normal Mode This is the mode the FPC 1000 uses to operate when not in one of the other special modes Select this mode to return to default operation Executive Mode Select this mode to prevent any changes from being made from the FPC 1000 The panel may be used to view any settings but changes adjustments are not allowed FPC Lock Out Mode Select this mode to prevent any menu from being accessed In Lockout Mode pressing any FPC button brings up a menu that requests a password You must enter the correct password to access that menu Set Password Use this menu to change the password You must know the current password to change it
6. e5 in See the Page 3 3 to customize the bottom three lines of the screen display Scrolling the title bar lt p gt reveals up to eight top level menu titles Main Status Audio if available I O A V Mute Presets Delay RGB Wideband only and Misc When a different menu is selected the displayed titles may shift but the selected title will remain highlighted The bottom buttons are used in the other menus Each of these screen menus is described later in this chapter Matrix 3200 6400 Series Switchers FPC 1000 User s Manual Extron Chapter 3 Using the FPC 1000 Front Panel Controller How to Use the Menus and Panel Buttons e Press any menu title button at any time to escape without making changes 4 OY Mute E Delay Misc d 11 E Use menu selections e e 2 eej with soft buttons eee e E El GE ADOIO Lit Put s Descriptive menu title Output Name ES I Nye Pat 3 6 I 17 o3 I Because the buttons are E dynamically reassigned to RGB Oo WO Oyo 0 a the title or option that audio appears next to it they are i m m m m O CI called soft buttons QA Not Muted mm Muted Instruction message appears here SP eee pp 000 0000 Use option selections le Select Output BESS to toggle B with soft buttons 9 geeeee ILE udia Mute A Unit e e o Figure 3 2 Using the bottom buttons with an FPC 1000 menu Each option for the displayed menu aligns w
7. Audio Gain Attenuation menu ooooccnnccccnncccncnnncccnnnnnnnnnnn cnc nan nnn cnn nnnncncan nn 3 12 Figure 3 12 Misc menu shown with System Reset selected oooooocicicicicinicicinoccccconcncnananccnnnnnss 3 13 Figure 3 13 Misc LCD menu for Adjusting LCD Contrast Light and Menu Time out 3 14 Figure 3 14 Misc Security menu shown with Normal Mode selected oooooocccinicicinincccccaccncos 3 15 Extron Matrix 3200 6400 Series Switchers FPC 1000 User s Manual Contents Figure 3 15 Misc System Reset menu shown with Factory Default selected oooooooocccncn 3 16 Figure 3 16 Terminal Mode display of RS 232 dialog example of a Tie command 0 3 17 Figure 3 17 Status Remote menu showing MKP MCP 1000s and their Status ooooooconiccc ninnc 3 18 Figure 3 18 Error screen showing message Category and NUMDEL ooooocccccinconccicinncaarnccccnanonnnos 3 19 The following icons may be used in this manual A y Da FO By Important information for example an action or a step that must be done before proceeding A Warning possible dangerous voltage present A Warning possible damage could occur A Note a Hint or a Tip that may be helpful Possible Electrostatic Discharge ESD damage could result from touching electronic components Indicates word definitions Additional information may be referenced in another section or in another document Ex
8. Lire les instructions Prendre connaissance de toutes les consignes de s curit et d exploitation avant d utiliser le mat riel Conserver les instructions Ranger les consignes de s curit afin de pouvoir les consulter l avenir Respecter les avertissements Observer tous les avertissements et consignes marqu s sur le mat riel ou pr sent s dans la documentation utilisateur Eviter les pi ces de fixation Ne pas utiliser de pi ces de fixation ni d outils non recommand s par le fabricant du mat riel car cela risquerait de poser certains dangers Sicherheitsanleitungen Deutsch Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung Instandhaltung geben Dieses Symbol soll den Benutzer darauf aufmerksam machen da im Inneren des A Geh uses dieses Produktes gef hrliche Spannungen die nicht isoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bevor Sie das Ger t zum ersten Mal verwenden sollten Sie alle Sicherheits und Bedienungsanleitungen genau durchlesen und verstehen Aufbewahren der Anleitungen Die Hinweise zur elektrischen Sicherheit des Produktes sollten Sie aufbewahren damit Sie im Bedarfsfall darauf zur ckgreifen k nnen Befolgen der Warnhinweise Befolgen Sie alle Warnhinweise und Anleitungen auf dem Ger t oder in der Benutzerdokumentation Keine Zu
9. 1000 Front Panel Controller Chapter 1 Whatis an FPC 1000 Video Conference Room The FPC 1000 is an optional Front Panel Controller designed to operate as part of Extron s Matrix 3200 6400 Series Switching system In most installations RS 232 program control will be used because it is more powerful and complete RS 232 control can be from a PC using Extron s Windows control software or from a touch screen or any other controlling device capable of generating the proper commands The external device could be a PC using Extron s Windows software or a user supplied controller such as AMX Panja Crestron etc One Matrix 3200 6400 Series system may consist of up to 6 BMEs Basic Module Enclosure switching up to 64 inputs and 64 outputs The different modules that make up a system are controlled as one by communication links that connect the modules Therefore one Front Panel Controller will control all the modules in the system and must be installed in the master BME Presentation Training Room FPC 1000 Figure 1 1 An FPC 1000 shown as part of a Matrix 3200 6400 Series Switcher System Matrix 3200 6400 Series System Modules Matrix 3200 6400 Series Switchers may be custom built for a specific application from the video sync and audio modules as well as remote key pads or control panels MKP 1000 and MCP 1000 and a front panel controller FPC 1000 This manual deals with the FPC 1000 Following is a list
10. Audio IO ary Mute La Status y E Heerlen ano est Switcher status 5 button at any time FPC version 1 02 Copyright 1999 to escape without making changes BME 1 Status Wideband Fart Number 68 2 58 HH16 Firmware Version 1 88 Physical Input Size 6 4 TO get nere tram ine Main Menu Physical Diepue Size E4 Eten Virtual Input Size 64 Virtual Output Size 64 Main Fower Supply Active Redundant Power Supply Hot Installed Last Error Code Figure 3 4 System Status menu on the FPC 1000 Status Check Status IZA Select BME View status Other choices Terminal monitor RS 232 activity Fist keypads panels address mode configuration FF test front panel To select a Basic Module Enclosure BME use either of the lower left buttons av When the BME is selected its status will be displayed on the screen BME n Status Wideband also Sync Audio or Low Resolution Part number of the selected BME This example is 60 250 HH10 Firmware Version x xx Physical Input Size the number of physical inputs 64 Physical Output Size the number of physical outputs 64 Virtual Input Size if not configured for virtual operation show physical inputs Virtual Output Size if not configured for virtual operation show physical outputs Main Power Supply Active Redundant Power Supply Not Installed Last Error Code 00 if no errors The three options at the bottom of the screen are used to display information
11. Press the RGB button to unmute video and the Audio button to unmute audio for that output channel Changes are saved and take effect immediately Extron Matrix 3200 6400 Series Switchers FPC 1000 User s Manual 3 2 Using the FPC 1000 Front Panel Controller Chapter 3 Instant Mute Unmute Front Panel Controls Instant RGB Mute Unmute This button allows all RGB video outputs to be muted y independent of any programmed muting Press once and the LED lights to indicate that all RGB outputs are muted Press the button again to restore the previous mute status For example if outputs 2 29 and 35 were already muted turning this RGB Mute function Off will unmute all except those three outputs For muting of individual outputs from the panel see Page 3 11 B Because RGB mute is done by switching off the RGB signal and leaving the sync on this button does not operate with composite or S video system z Instant Audio Mute Unmute This button allows all audio outputs to be muted Sl 45 Diagnostic LEDs independent of any programmed muting Press once and the LED lights to indicate that all audio outputs are muted Press the button again to restore the previous mute status That is any audio outputs that were muted before will remain muted For muting of individual outputs from the panel see Page 3 11 The Audio button and LED will not operate if the system has no audio module At the bottom of the BME front pan
12. another an adjustable delay is available for each output This allows the 3200 6400 systems to accommodate the switching characteristics of any display device Those systems with RGBS or RGBHV video use Extron s Triple Action Switching for smooth transitions when switching from the image of one input source to another This is done by switching the sync and RGB signals separately in a prescribed sequence Because some projectors may require different delay times Extron has an adjustable time delay for each output device Using an example of a large screen projector and a switcher top of Figure 3 8 switching from input A to input B normally works as follows 1 Input A is being displayed by the output device and a request is received to switch to input B from a panel button or a program command 2 Both RGB and sync are switched from input A to input B as a single action The displayed image is scrambled as input A turns off and input B turns on This is because the picture is being displayed before the sync locks in Although it may be brief this unstable display can be annoying 3 Input B is now displaying normally to the output device Single Action switching Triple Action switching Figure 3 8 Normal Single Action Switching top as Compared to Triple Action Switching bottom Refer to the bottom half of Figure 3 8 to switch from input A to input B with Triple Action s
13. any menu title button at any time to escape without making changes Ae Mute Audio Mute Unmute Only available if system has audio avy Mute gt Select output 0 E Audio Not Muted Huted Instruction message appears here gt Select Output eee LE Mute Use option selections with buttons gt Figure 3 10 A V Mute menu with RGB and Audio Muted for Output 01 O Use the speed knob or the scroll buttons to select the output to be muted or unmuted The A V Mute screen above shows examples of muted and not muted unmuted Video Mute Unmute conditions on the left Press RGB button to toggle the RGB mute function On or ere Off for the selected output Composite video or S video cannot be muted Likewise press the Audio button to toggle the audio mute function On or Off for gt Select output the selected output RGB The other two mute buttons Mute All and All UnMute are global because they O affect all outputs The mute functions in this menu operate differently from the instant mute buttons on the panel to the left of the LCD screen on Page 3 3 RGB Press this button to toggle RGB video Mute On or Off for the selected output This option does not operate with composite or S video system Mute All Neal Audio At Mute Press this button to toggle Audio Mute On or Off for the selected output rote All This option will not be available if the system has no audio Mute Al
14. be installed in the master unit address 0 eo Matrix 3200 6400 Series AEREN FPC 1000 Extron ext E a8 MATRIX 6400 O WIDEBAND VIDEO 8 Figure 2 1 An FPC 1000 mounted in a Matrix 3200 6400 Series Switcher BME Installing the FPC 1000 i If the FPC 1000 was ordered with the Matrix 3200 6400 Series system it will already be mounted If it is being added or changed use the following procedure together with the illustrations on Page 2 2 All that is needed to install the FPC 1000 is the RJ cable assembly that comes with the unit If installing the FPC 1000 in an existing system it will replace the blank front panel in BME 0 High voltage is present on the back of the FPC panel as well as inside the BME Remove power from the Matrix 3200 6400 Series system by turning the power switch OFF and unplug the AC power cord Use a flat screwdriver or a thin coin to turn the two quarter turn fasteners on the blank front panel counterclockwise to release the panel Figure 2 2a Tilt the panel slightly out at the top and lift it up to free the tabs that hold the bottom to the BME enclosure These may be snug Set the blank front panel aside O Inside the BME locate the RJ connector on the main controller board mounted on the floor of the enclosure Plug one end of the RJ cable that came with the FPC 1000 into the female connector on the main controller board and the other to the co
15. die auf dem Produkt angegebene Stromquelle betrieben werden Dieses Ger t wurde f r eine Verwendung mit einer Hauptstromleitung mit einem geerdeten neutralen Leiter konzipiert Der dritte Kontakt ist f r einen Erdanschlu und stellt eine Sicherheitsfunktion dar Diese sollte nicht umgangen oder au er Betrieb gesetzt werden Stromunterbrechung Um das Ger t auf sichere Weise vom Netz zu trennen sollten Sie alle Netzkabel aus der R ckseite des Ger tes aus der externen Stomversorgung falls dies m glich ist oder aus der Wandsteckdose ziehen Schutz des Netzkabels Netzkabel sollten stets so verlegt werden da sie nicht im Weg liegen und niemand darauf treten kann oder Objekte darauf oder unmittelbar dagegengestellt werden k nnen Wartung Alle Wartungsma8nahmen sollten nur von qualifiziertem Servicepersonal durchgef hrt werden Die internen Komponenten des Ger tes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall dieses Ger t selbst ffnen da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und oder andere Gefahren bestehen Schlitze und ffnungen e Wenn das Ger t Schlitze oder L cher im Geh use aufweist dienen diese zur Vermeidung einer berhitzung der empfindlichen Teile im Inneren Diese ffnungen d rfen niemals von anderen Objekten blockiert werden Litium Batterie Explosionsgefahr falls die Batterie nicht richtig ersetzt wird Ersetzen Sie verbrauc
16. is also tied to Input 10 Input Output This button toggles between working with an input or with an output When the desired output has been selected press the Input button and then select an input number to tie to that output For this example the new instruction message for a selected input will be Select RGB Audio input Take to tie The speed knob appears over both the RGB and Audio input numbers next to the selected output unless RGB Audio breakaway switching is being used Turn the knob to scroll through the available input numbers or to indicate that no input will be tied to the selected output Several ties can be made before pressing Take Any pending changes will be underlined __ until the Take button is pressed 3 5 Matrix 3200 6400 Series Switchers FPC 1000 User s Manual Extron Chapter 3 Using the FPC 1000 Front Panel Controller Output name change Mico o Select output gt Marie KID Step to position Breakaway b G 2 E Le Output Input q Sources q ar Ep r Name Use this button to change the name of the Input or Output that is currently selected After pressing the Name button the instruction message becomes Enter new name The option soft buttons become Caps Delete Take and ESC The speed knob symbol will appear as a cursor above the character position of the name you are about to chan
17. three years from the date of purchase In the event of malfunction during the warranty period attributable directly to faulty workmanship and or materials Extron Electronics will at its option repair or replace said products or components to whatever extent it shall deem necessary to restore said product to proper operating condition provided that it is returned within the warranty period with proof of purchase and description of malfunction to USA Canada South America Europe Africa and the Middle East and Central America Extron Electronics Europe Extron Electronics Beeldschermweg 6C 1230 South Lewis Street 3821 AH Amersfoort Anaheim CA 92805 USA The Netherlands Asia Japan Extron Electronics Japan Extron Electronics Asia Daisan DMJ Bldg 6F 135 Joo Seng Road 04 01 3 9 1 Kudan Minami PM Industrial Bldg Chiyoda ku Tokyo 102 0074 Singapore 368363 Japan This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or non Extron authorized modification to the product If it has been determined that the product is defective please call Extron and ask for an Applications Engineer at 714 491 1500 USA 31 33 453 4040 Europe 65 6383 4400 Asia or 81 3 3511 7655 Japan to receive an RA Return Authorization number This will begin the repair process as quickly as possible Units must be returned insured with s
18. Each version is made up of a metal panel with an LCD display 12 buttons and a knob There are two tabs that hold the bottom in place and two 1 4 turn captive screws to hold the top in place The slots in the screws can accommodate a screwdriver or a small coin The FPC 1000 is an option in a Matrix 3200 6400 Series Matrix Switching system but one unit provides Front Panel operation for one system It is installed in the master unit BME 0 normally the top unit The only electrical connection to the system is through an RJ 45 cable See Chapter 2 for installation The two panel dimensions are FPC 1000 for 5U __ 88 295 02 __ 6 475 H x 13 980 W 16 45 cm x 35 51 cm _ with rounded corners R 250 FPC 1000 for 7U __ 88 295 01 __ 8 475 H x 13 980 W 21 526 cm x 35 51 cm _ with rounded corners R 250 LCD display pixel array __ 320 x 240 Speed knob operation __ endless no physical max min limits Matrix 3200 6400 Series Switchers FPC 1000 User s Manual Extron Matrix 3200 6400 Series Front Panel Controller User s Manual Chapter Two Installing the FPC 1000 Install Procedure Installation e FPC 1000 Front Panel Controller Chapter 2 The FPC 1000 offers local control at the switcher because it mounts as a front panel on the master BME Basic Module Enclosure as shown in Figure 2 1 Ina system with more than one BME the FPC 1000 must
19. Extron Electronics E INTERFACING SWITCHING AND DISTRIBUTION User s Manual FPC 1000 a 6100 s mos J WIDEBANDVIDEO Matrix 3200 and 6400 Serie Front Panel Controller FPC 1000 68 355 02 Printed in the USA Precautions Safety Instructions English AN This symbol is intended to alert the user of important operating and maintenance servicing instructions in the literature provided with the equipment A This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product s enclosure that may present a risk of electric shock Caution Read Instructions Read and understand all safety and operating instructions before using the equipment Retain Instructions The safety instructions should be kept for future reference Follow Warnings Follow all warnings and instructions marked on the equipment or in the user information Avoid Attachments Do not use tools or attachments that are not recommended by the equipment manufacturer because they may be hazardous Consignes de S curit Francais Cesymbole sert avertir l utilisateur que la documentation fournie avec le mat riel AN contient des instructions importantes concernant l exploitation et la maintenance r paration A Ce symbole sert avertir l utilisateur de la pr sence dans le bo tier de l appareil de tensions dangereuses non isol es posant des risques d lectrocution Attention
20. T Mute Honitor 3206 8464 Host Communications Tupe Code ASCII Mode RX received e q command TX transmitted f g response position output number in that position input e g output 1 has input 01 RH ET TH Outer Ines Al14 output 7 has input 03 R Aa I which the command said Tk current Tie In 3 to Gut 7 Ta Grp R Be e41 88 TH 6i 82 66 GG 66 p AS a Be an Ga 66 GG GA HA aa All RH BAXTER VA TH 66 BG 66 Ga 66 Ga Be Ga Be GA a Be ES 66 HA AG A115 Start RA Figure 3 16 Terminal Mode display of RS 232 dialog example of a Tie command and a response The use of controls described here do not affect those communications that is they do nat interrupt the transmitting or receiving of data between the Matrix 3200 6400 and the host but only affect what is being displayed O Use the speed knob or the scroll buttons bottom corner buttons to scroll up and down large blocks of data Clear This button clears the display for example when checking communication dialog and you don t want to confuse old data with new data Pause Resume This button toggles between Pause temporarily stop the flow of new data displayed and Resume allows data flow to continue Hex ASCII When in ASCII mode as shown in Figure 3 16 this is indicated at the top of the displayed data and Hex appears above the button below Press the button to toggle between Hex and ASCII display ESC Pres
21. ayed information ESC Press ESC to return to the previous status menu e See MKP 1000 User s Manual 68 355 01 or MCP 1000 User s Manual 68 456 01 for more information Extron Matrix 3200 6400 Series Switchers FPC 1000 User s Manual 3 18 Using the FPC 1000 Front Panel Controller Chapter 3 Error Screens If an error occurs the FPC 1000 returns to the Main menu display and flashes a message in the center of the screen similar to the one in Figure 3 18 A Communications Failure ME Status oc gt amp o turno Matrix 3200 6400 Series Front Panel Version 1 02 Copyright 1999 Extron Electronics Figure 3 18 Error screen showing message category and number The first line is the error message Communications Failure The next line gives a category in this case Status and a number 5 Should an error occur write this information down and call Extron support If an FPC 1000 is connected to a BME other than address 0 an error message will appear across the bottom of the Main menu screen This could happen for example if there is more than one FPC on a system The error message is Unit probably not the master BME If this message appears the FPC cannot be used Check that there is only one FPC on the system and that it is installed in the BME with its address switch set to 0 master Tie A connection between an Input and an Output Set of Ties Connecti
22. cocanocinononcccconnnncnnnrn nn cnn ncn cnn nn cnn 2 2 Figure 2 20 Install th FPO 1000 00 ls 2 2 Figure 2 3 The FPC 1000 shown mounted in a Matrix 3200 6400 Series BME s11cccesseeeees 2 3 Chapter 3 Using the Front Panel Front Panel Operation Menu FUNCTIONS ccoconoccccnnnccnnnoncncnonon cn conan nana n cnn rra 3 1 How to Use the Menus and Panel BU LONS 0 0 cecececececeeeeeeeeeeeeeeaeeeeeaeeeeeeeeeeeaaeeeecaeeseeeaaeeessaaeesseaes 3 2 Instant Mute Unmute Front Panel Controls oococccccnnicccnnnnccccnncccnnnnnccc conan rra nnn cra 3 3 DiaGnOStiGILE DS siii ET cado 3 3 Main Menu Standard and Customized c oooncccccnnoccccnccccnonancncnonnannnnn cnn nano cnn nana nana ran 3 3 System Status Meninas 3 4 I O Menu DY QU PUD escort ratita 3 5 Br ak away ssecivivied centered dd die Ad A A 3 6 Virtual Switching and Room Presets cccccecececeeeseeeeeeceeeeeeeeeeseaeeeeseaaeeeeeaeeeeseeeeessaeeseaes 3 6 Global Presets Menu siria Aa 3 7 Room Presets Menu c ooomccccnnnncccnnnccconannnccnnnn nc cnn cnn 3 8 Triple Action Switching with Adjustable Delay Wideband models oooocnicccinnncccninnccinncccoo 3 9 Delay Menu for Triple Action Switching oooocnicnninicccnnnncconccccnnn cacon ran rn nr rca 3 10 AIN Mute MON sii os 3 11 Audio Menu by Input cc ceeeeeeccceceeeeeseeceeeeeeneeeeeeeeeensaaeeaeeeensaaeeeeseeensaaeceeseeeeeseeaeeeenenseeaes 3 12 MISC MENU cuota A A chi AA o 3 13 M
23. el below the FPC 1000 panel there are several LEDs that monitor the 3200 6400 switcher BME These are explained in the Matrix 3200 6400 Switcher manuals The name and function of each LED is as follows Power Supplies These four green LEDs indicate that the voltage is present If there is no second power supply the two LEDs for Redundant will not be lit Primary V POWER SUPPLIES COMMUNICATIONS Primary V vv RS232 BME REMOTE STATUS Redundant V O O Primary x O _O O O Redundant V O O REDUNDANT rx O O O DIAGNOSTICS J Figure 3 3 Diagnostic LEDs on the BME Front Panel Communications The red LEDs indicate Tx Transmit and the green LEDs indicate Rx Receive for three categories RS 232 to show transmit receive activity over the serial bus BME to show communication activity between I O modules BMEs Remote not on Sync Modules to show communication between remote keypads or panels MKP 1000 or MCP 1000 and the Master BME module 0 The yellow Status LED indicates On normal Off there is an error Blinking BME is busy communicating Main Menu Standard and Customized Customize Main menu Hold lower outside buttons and turn power ON E Symbol appears above left most character position gt 0 Select character Change characters and move to next o position or next line lt KD Step to position Hest Step to next line The Mai
24. en Press Adjust The selected Audio Input number is displayed between the two vertical lines with the three Aldi o Audio Mute Only available if system has audio Acii o gt 0 Select input Adjust I set aB level Take Lo Other choices Default 0 dB loka 1 set all the same higher and three lower input numbers displayed to the right and left of the selected input Use the scroll buttons lt p gt or the speed knob to select the audio input number to adjust and then press Adjust Adjust Press Adjust to change the gain or attenuation level for the selected input When finished press Take to make the change or press Global or Default explained below A confirmation message will appear Take Press Take to save the changes or ESC to exit without saving changes Global Sets the gain attenuation values for all inputs to be the same as the one selected For example you may select an input adjust its gain for 3 dB and press Global All input gains will be 3 dB Default This button resets all input delays to a delay time of 0 0 seconds This is also the factory default After pressing Take the first time Global or Default a warning message appears to allow confirmation of the changes Press Take to accept the changes Extron Matrix 3200 6400 Series Switchers FPC 1000 User s Manual 3 12 Using the FPC 1000 Front Panel Controller Chapter 3 Misc Menu Press a
25. et press Recall The response message is Preset recalled Delete This button changes the preset name to unassigned e The Room option will only appear if Rooms have been set up through Extron s virtualization control software Room Press the Room button The description at the top is Save Recall Room Presets Name Presets The next page shows an example of a Room Preset menu 3 7 Matrix 3200 6400 Series Switchers FPC 1000 User s Manual Extron Chapter 3 Using the FPC 1000 Front Panel Controller Room Presets Menu Press any menu title button at any time to escape without tz SaverRecall Room Room 81 Main Cnt Rn Preset Te Presets Nane Presets making changes Cunassigned Outputs Cunass igne al A Cunass ianed as Security Az Ed To get here from the Main Menu as press e Presets Eumass ianed Room Instruction message appears here gt Use option selections with buttons gt Figure 3 7 Room Presets menu Cunass igned Cunass ianed Cunass iqned Edit Room Preset Presets gt Room Foort T to change rooms Select preset Hamne gt Step to position Select character O Take e The Room Preset menu will show room 01 with its 10 presets listed below it and any virtual outputs to the right Press Room to select a different room with its presets and virtual outputs listed Room Preset 01 i
26. ety feature do not attempt to bypass or disable it Power disconnection To remove power from the equipment safely remove all power cords from the rear of the equipment or the desktop power module if detachable or from the power source receptacle wall plug Power cord protection Power cords should be routed so that they are not likely to be stepped on or pinched by items placed upon or against them Servicing Refer all servicing to qualified service personnel There are no user serviceable parts inside To prevent the risk of shock do not attempt to service this equipment yourself because opening or removing covers may expose you to dangerous voltage or other hazards Slots and openings If the equipment has slots or holes in the enclosure these are provided to prevent overheating of sensitive components inside These openings must never be blocked by other objects Lithium battery There is a danger of explosion if battery is incorrectly replaced Replace it only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Avertissement Alimentations Ne faire fonctionner ce mat riel qu avec la source d alimentation indiqu e sur Vappareil Ce mat riel doit tre utilis avec une alimentation principale comportant un fil de terre neutre Le troisi me contact de mise la terre constitue un dispositif de s curit n essayez pas de la con
27. ge Use the knob to scroll through the characters blank special characters 0 9 and A Z The letters appear as upper case To change letters to lower case press the Caps button for each letter to be changed When in the left most position the Delete button eliminates the character position and the information to the right moves over to fill in the space When the m ieg symbol is in any other position a space replaces the gt Select output character i Iret When the desired character appears under the symbol position use the lower right button gt to step the next Select input I character position Use the lower left button to step LJ Hame back to the previous position ag Step to position When finished editing the name press Take to save it or Select character ESC to exit without saving changes At this time a message Connection Made appears briefly P take Input name change Breakaway means that not all of the components of an input are switched to or follow the same output An example of audio video breakaway would be when video but not the audio from input 2 ties to output 8 Output 8 may have no audio or it may be tied to audio from input 5 as shown to the left Another form of breakaway would be to switch the R red G green or B blue planes separately This is plane breakaway When this type of breakaway is being used will appear in place of the inpu
28. hipping charges prepaid If not insured you assume the risk of loss or damage during shipment Returned units must include the serial number and a description of the problem as well as the name of the person to contact in case there are any questions Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality performance merchantability or fitness for any particular use In no event will Extron Electronics be liable for direct indirect or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage Please note that laws vary from state to state and country to country and that some provisions of this warranty may not apply to you ee As Extron Electronics USA Extron Electronics Europe Extron Electronics Asia Extron Electronics Japan a S 1230 South Lewis Street Beeldschermweg 6C 135 Joo Seng Road 04 01 Daisan DMJ Building 6F a ta Anaheim CA 92805 3821 AH Amersfoort PM Industrial Building 3 9 1 Kudan Minami e USA The Netherlands Singapore 368363 Chiyoda ku Tokyo 102 0074 Japan turio 714 491 1500 31 33 453 4040 65 6383 4400 81 3 3511 7655 www extron com Fax 714 491 1517 Fax 31 33 453 4050 Fax 65 6383 4664 Fax 81 3 3511 7656 2002 Extron Electronics All rights reserved
29. hte Batterien nur durch den gleichen oder einen vergleichbaren Batterietyp der auch vom Hersteller empfohlen wird Entsorgen Sie verbrauchte Batterien bitte gem den Herstelleranweisungen Advertencia Alimentaci n el ctrica Este equipo debe conectarse nicamente a la fuente tipo de alimentaci n el ctrica indicada en el mismo La alimentaci n el ctrica de este equipo debe provenir de un sistema de distribuci n general con conductor neutro a tierra La tercera pata puesta a tierra es una medida de seguridad no puentearia ni eliminaria Desconexi n de alimentaci n el ctrica Para desconectar con seguridad la acometida de alimentaci n el ctrica al equipo desenchufar todos los cables de alimentaci n en el panel trasero del equipo o desenchufar el m dulo de alimentaci n si fuera independiente o desenchufar el cable del recept culo de la pared Protecci n del cables de alimentaci n Los cables de alimentaci n el ctrica se deben instalar en lugares donde no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos Reparaciones mantenimiento Solicitar siempre los servicios t cnicos de personal calificado En el interior no hay partes a las que el usuario deba acceder Para evitar riesgo de electrocuci n no intentar personalmente la reparaci n mantenimiento de este equipo ya que al abrir o extraer las tapas puede quedar expuesto a voltajes peligrosos u otros riesgos Ranuras y aberturas Si el eq
30. is display uses a diagonal box with the selected output in the middle with four adjacent output numbers above and four below Along the left side of each output is the video RGB input number that is tied to it if no tie To the right of each output is the Audio input number that is tied to it if no tie The selected output in the larger diagonal box also displays the given names for the output and input s The RGB and Audio input numbers are often the same unless breakaway switching is used or if the system has no audio The speed knob indicator is shown in the center of the screen above the output number to indicate that the knob may be used to select a different output Note the instruction message at the bottom of the screen says Select output to edit Turning the knob changes the selected output number as its given name is displayed in the large diagonal box and the RGB or Video and Audio inputs are displayed on either side of the output information If the system is composite video or S video not Wideband the word Video appears instead of RGB When the I O menu first appears it shows Output 01 selected In this example Output 01 has been given the name Conf Room 1 which might be a large monitor located in the main conference room It is tied to both the video RGB and audio source through Input 10 which has been named Cam 1 Room 3 Below the selected output notice that Output 03
31. isc Menu LCD Adjust coocccncccccnnoccccononannnnnn conan cnn nono nnnnnnn cnn nan rra n rn rana nannr na nan anna 3 14 Mise Menu Security os cd ia 3 15 Misc Menu A n aiaa naa anaa aap iata aade aaet 3 16 status Ment Terminal M0de xico a a aS 3 17 Status Menu MKP MCP 1000 Mode oooocccccoccccooccccconooncnonnccnnnnoncnnonn na nnnnn nc cnn oran nnn nn cnnnnn cnn 3 18 Error Sorens A ia 3 19 Chapter 3 Illustrations Figure 3 1 Using the top buttons with an FPC mMenu uu eccccccccecceseeeeceeeeecteneeeceeeeeeseceeeetesaeeseeeeeetees 3 1 Figure 3 2 Using the bottom buttons with an FPC Menu ooociccccicccnoncccncncnncnnno no cnn co nan nano rra 3 2 Figure 3 3 Diagnostic LEDs on the BME Front Panel ccccecccccseceseeseseeseeeesseetseeseneeeneesnneeeseees 3 3 Figure 3 4 Status menu on the FPC 1000 ooocccinccccicccnccccnoninonncononn corn nn 3 4 Figure 3 5 I O menu for a system with both video RGB and audio ooooocccnccicinicccccnnoccccnannnnnnnn 3 5 Figure 3 6 Global Presets Menu oooooccconccccccccccononccccnnnnncnnnrn cnn nnnnc cnn cnn nn cnc 3 7 Figure 3 7 ROOM Presets Menu coco A A 3 8 Figure 3 8 Normal Switching top as Compared to Triple Action Switching bottom 3 9 Figure 3 9 Delay menu not available with composite Or S video ooooooccoincccnnonccccnonccncnccccnnnnnss 3 10 Figure 3 10 A V Mute menu with RGB and Audio Muted for Output Ol oocccinccccinccccnnnccccconnnos 3 11 Figure 3 11
32. ith one of the lower soft buttons The option is selected or executed by pressing that button Thus the function of each button is dynamically assigned to fit the screen display Pressing one of these buttons usually brings up a new screen with a new instruction message and a new set of functions for the lower buttons Figure 3 2 shows an A V Mute menu as an example of how the lower buttons are used For this example the bottom buttons have the following functions left to right e the left button scrolls the output numbers to the left to change the selection e 2nd button mutes RGB video Wideband systems only e 3rd button mutes Audio If no audio this will not show e 4th button is for Mute All the entire system audio and video outputs e 5th button is All Unmute the entire system audio and video outputs the right button scrolls the output numbers to the right to change the selection The middle of the screen displays the selected output number to be muted or unmuted together with its given name It is separated from the adjacent output channels by vertical bars Press either the lower right or lower left button lt q p gt or use the speed knob to change the selected output O Wherever this symbol is displayed in a menu indicates that the speed knob on the front panel may be used to change a value or selection For the example in Figure 3 2 output 01 shows Muted for both video RGB and Audio
33. l Press this button to mute both RGB and Audio for all outputs UnMute All art Hute All UnMute Press this button to unmute both RGB and Audio for all outputs All UnMute Unlike the buttons to the left of the front panel screen any outputs that had previously been muted will not return to that state but will be unmuted See page 3 3 for a description of the RGB Mute and Audio Mute instant buttons that are separate from the LCD screen buttons 3 11 Matrix 3200 6400 Series Switchers FPC 1000 User s Manual Extron Chapter 3 Using the FPC 1000 Front Panel Controller Audio Menu by Input Press any menu title o A Y Mute button at any time i i to escape without making changes To get here from the Main Menu press e Audio H H ES ti 3 7 5 E l 0 l 3 5 7 El al 3 5 LII FFP11111 dE 15 1 3 Instruction message appears here gt Select Inf Use option selections with buttons gt Figure 3 11 Audio Gain Attenuation menu This menu is used to display and adjust the gain or attenuation of each audio input The range is from 9dB to 15dB The dB level is shown as a bar graph above or below the OdB line and as a or number below the graph For this example Input 01 is at OdB while Input 02 is at 2dB e It does not display the actual output level but the gain or attenuation applied to the input signals The instruction message says Select Input Th
34. l Controller mounted in a BME The FPC 1000 also includes the following features e 320 x 240 pixel LCD graphic display Instant global RGB video mute unmute button from the panel only with wideband systems Press this button to mute all RGB outputs press again to restore the previous mute unmute settings e Instant global audio mute unmute button from the panel systems with audio Press once to mute all audio outputs press again to restore all previous mute unmute settings e Soft button functions that are dynamically assigned For each menu the function name or title on the screen changes to fit the operation of that screen e Messages are displayed during each operation to inform and instruct the user e The Speed knob is dynamically assigned to be used with each menu A rotating symbol for the knob appears on the screen above or next to a control or adjustment allowing that function to be adjusted or selected quickly e Custom information such as company name and telephone number may be entered and displayed at the bottom of the main menu Refer to Chapter 2 for installation and Chapter 3 for operation Extron Matrix 3200 6400 Series Switchers FPC 1000 User s Manual 1 2 Introduction and Features FPC 1000 Front Panel Controller Chapter 1 Specifications The FPC 1000 is built in two sizes one to fit in a 5U enclosure and one for a 7U enclosure Otherwise appearance and operation are the same
35. le input 9 could be a VTG 200 Video Test gt Generator to send the test pattern to all outputs at the same time COR Take 1 From the Misc menu select Auto Test Output Mode and press Take Select input 2 Select the input number to tie to all outputs and press Take The tie is made T to tie to all outputs to all outputs overriding previous ties and the screen message changes to Take Press ESC when done testing Test outputs 3 a ESC Press the ESC button to return the system to its previous state All ties that were previously active are reconnected 3 13 Matrix 3200 6400 Series Switchers FPC 1000 User s Manual Extron Chapter 3 Using the FPC 1000 Front Panel Controller Misc Menu LCD Adjust Press any menu title button at any time to escape without making changes To get here from the Main Menu press e Misc e LCD Adjustments The information above the adjustment bar changes with each operation gt Instruction message appears here gt Use option selections with buttons gt Matrix 3200 6400 Series LCD Contrast A Press Appropriate Button to Select a 4 Contrast Light Menu Timeout Figure 3 13 Misc menu for Adjusting LCD Contrast Light and Menu Time out Use the Misc Menu on Page 3 13 and select LCD Adjustments to get this menu LCD Adjustments Selecting this menu displays what looks like the Main menu with added information for making the adjus
36. n menu shown in Figure 3 1 displays the Extron logo switcher model and software version This is the starting point for going to other menus The operation of this menu is described in the example on page 3 1 On power up tests are made and the system status is checked and stored During this period messages appear along the top of the screen that say Establishing Communications and then Initializing and then the menu titles appear The bottom three lines of the main menu can be customized for the installation For example it could be used to display information about the company responsible for the system a phone number etc XYZ A V Systems Inc To do this hold the two bottom corner buttons while turning power ON See diagram left The knob symbol acts as a cursor marking the character position to be changed Turn the knob to change that character Use the lt q gt buttons to move to another position and press the Next button to change lines Use the Caps button to change case Press Take when finished editing the text Matrix 3200 6400 Series Switchers FPC 1000 User s Manual Extron Chapter 3 Using the FPC 1000 Front Panel Controller System Status Menu Press any menu title This menu displays the configuration information and status for each BME Basic Module Enclosure in the system as illustrated in the screen in Figure 3 4 It is only for viewing Status and not for changing it
37. nnector on the FPC 1000 board It doesn t matter which end Place the FPC 1000 in front of the BME opening and align the FPC 1000 tabs with the bottom edge in the enclosure Drop press the panel down and inward to fit into opening The metal tabs should fit snugly O Use a flat screwdriver or a thin coin to turn the two quarter turn fasteners on the FPC 1000 clockwise to secure it in place Matrix 3200 6400 Series Switchers FPC 1000 User s Manual Extron Chapter 2 FPC 1000 Front Panel Controller Installation Blank front panel Figure 2 2a Remove the blank panel A__ High voltage is present on the back of the FPC panel as well as inside the BME Figure 2 2b Connect the RJ cable Do NOT touch IC chips Figure 2 2c Install the FPC 1000 in a Basic Module Enclosure Extron Matrix 3200 6400 Series Switchers FPC 1000 User s Manual 2 2 Installation e FPC 1000 Front Panel Controller Chapter 2 Figure 2 3 The FPC 1000 shown mounted in a Matrix 3200 6400 Series Basic Module Enclosure O With the FPC 1000 in place apply power to the system Go to Chapter 3 for FPC 1000 operation 2 3 Matrix 3200 6400 Series Switchers FPC 1000 User s Manual Extron Matrix 3200 6400 Series Front Panel Controller User s Manual Chapter Three Using the FPC 1000 Front Panel Operation Menu Functions How to U
38. ny menu title button at any time to escape without making changes Misc LED Adjustments System Reset Security Lockout LCD Contrast amp Back Light Security Lockout System Reset Auto Test Output Mode Take l Follow instructions for selected item Instruction message appears here gt Use option selections with buttons gt A A M Figure 3 12 Misc menu shown with System Reset selectea Use the scroll buttons or the speed knob to select one of the four options from this menu This example shows System Resets highlighted Press Take to display the menu for the selected function System Resets See Page 3 16 for details on the functions that can be reset LCD Adjustments See Page 3 14 to make adjustments that relate to the LCD panel Security Lockout This selection brings up a menu that asks for a password Use the speed knob to select a character and the left right buttons to step to the next character position Press Take when finished If the password is incorrect the Enter Password message remains If the password is correct a menu appears to allow Executive Mode to be activated or deactivated See Page 3 15 for details on the different security features Auto Test Output Mode This selection allows one input to be temporarily selected and tied to all outputs Caen ee for testing purposes The flow diagram to the left shows the steps required to set Misc up a test of all outputs For examp
39. of related documents 68 355 01 MKP 1000 User s manual 68 355 02 FPC 1000 User s manual this manual 68 355 03 Matrix 3200 6400 Series Audio Module User s manual 68 355 04 Matrix 3200 6400 Series Video User s manual 68 355 05 Matrix 3200 6400 Series Wideband Video amp Sync User s manual 68 355 06 Matrix 3200 6400 Series Cable Connector Card 68 456 01 MCP 1000 User s Manual 1 1 Matrix 3200 6400 Series Switchers FPC 1000 User s Manual Extron Chapter 1 FPC 1000 Front Panel Controller Introduction and Features FPC 1000 Features Modular Design The modular design of the Matrix 3200 6400 Series switchers allows users the flexibility of purchasing only the modules required In some systems an FPC 1000 may not be needed Panel Mount The Matrix 3200 6400 Series BMEs can be rack mounted in any conventional 19 rack The FPC 1000 mounts in place of the blank front panel in the master module BME 0 It is available for both the 5U and 7U enclosures Triple Action switching with adjustable delay For seamless switching from one RGB input to another an adjustable delay is available for each output This allows the Matrix 3200 6400 to accommodate the switching characteristics of any display device ree a Extron Electronics es Ate A sa y A tuno 6400 Se FPC 1000 MATRIX 6400 WIDEBAND VIDEO Figure 1 2 Matrix 3200 6400 Series Front Pane
40. ons between one Input and more than one Output Configuration Any Tie Set of Ties or Sets of Ties between Input s and Output s Active Configuration The configuration that is currently being used by the matrix Global Preset A configuration that has been stored that deal with physical input and output numbers not virtual Room Preset Virtual ties that have been configured and stored for use only by a specific room 3 19 Matrix 3200 6400 Series Switchers FPC 1000 User s Manual Extron FCC Class A Notice Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Note This unit was tested with shielded cables on the peripheral devices Shielded cables must be used with the unit to ensure compliance Extron s Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of
41. s ESC to return to the previous status menu 3 17 Matrix 3200 6400 Series Switchers FPC 1000 User s Manual Extron Chapter 3 Using the FPC 1000 Front Panel Controller Status Menu MKP Mode Status The Remote button displays information about the remote keypads and panels The example in Figure 3 17 shows the address mode configuration and heck Status cheg currently selected input number for each MKP MCP 1000 on the system Status l A Select BME View status Address This is the number programmed into that MKP 1000 or MCP 1000 Mode Each MKP 1000 or MCP 1000 is programmed to one of 3 modes Other choices Output Room Preset or Global E ee aai Config For Output mode this is the local output number assigned to this MKP is MCP 1000 For Room Preset mode this is one of 10 presets currently FF test front panel assigned to this MKP 1000 or MCP 1000 Room Config does not apply to Global mode Input the input number currently selected by the MKP 1000 CA status IM Display Remote Information Address Pode Config Input Ae Output Az Bl AS Room Preset ad ao To get here from the Main Menu l2 Global NH A 62 press e Status e Remotes Total Remotes Found B3 Update Retrieves Remote Information Update ESC Figure 3 17 Status Remotes menu showing MKP MCP 1000s and their status Update This button checks for the latest MKP 1000 and MCP 1000 status and updates the displ
42. s highlighted in the center of the screen Use the speed knob to scroll through the ten selections The description at the top is Save Recall Room Presets Name Presets The instruction message at the bottom is Select Room Preset to Save Recall The buttons at the bottom of the screen are Save Recall Delete Global Room Name Each of these options will bring up an appropriate menu Save To review or edit press Save The menu to allow the name of the selected preset to be changed The knob symbol appears over the preset name Recall Press Recall to activate the selected Preset The response message is Preset recalled Delete Press this button to delete the selected Room Preset Global To view global presets press the Global button Room Press Room to step through the ten room choices As each room is selected its number and name are displayed above its ten possible presets Name The instruction message is Enter Name Take ESC to Execute Abort Rooms cannot be created or reconfigured from the FPC 1000 that must be done through RS 232 programming However rooms can be viewed activated Recalled deleted or renamed from the FPC 1000 Extron Matrix 3200 6400 Series Switchers FPC 1000 User s Manual 3 8 Using the FPC 1000 Front Panel Controller Chapter 3 Triple Action switching with adjustable delay Wideband models For seamless switching from one RGB input to
43. satzger te Verwenden Sie keine Werkzeuge oder Zusatzger te die nicht ausdr cklich vom Hersteller empfohlen wurden da diese eine Gefahrenquelle darstellen k nnen Instrucciones de seguridad Espa ol operaci n y mantenimiento o cambio de partes que se desean destacar en el q Este s mbolo se utiliza para advertir al usuario sobre instrucciones importantes de contenido de la documentaci n suministrada con los equipos voltaje peligroso sin protecci n aislante que puedan encontrarse dentro de la caja gt Este s mbolo se utiliza para advertir al usuario sobre la presencia de elementos con o alojamiento del producto y que puedan representar riesgo de electrocuci n Precaucion Leer las instrucciones Leer y analizar todas las instrucciones de operaci n y seguridad antes de usar el equipo Conservar las instrucciones Conservar las instrucciones de seguridad para futura consulta Obedecer las advertencias Todas las advertencias e instrucciones marcadas en el equipo o en la documentaci n del usuario deben ser obedecidas Evitar el uso de accesorios No usar herramientas o accesorios que no sean especificamente recomendados por el fabricante ya que podrian implicar riesgos Warning Power sources This equipment should be operated only from the power source indicated on the product This equipment is intended to be used with a main power system with a grounded neutral conductor The third grounding pin is a saf
44. se the Menus and Panel Buttons Diagnostic LEDs FPC 1000 Menus status adjustments resets Error Screens Using the FPC 1000 Front Panel Controller Chapter 3 Front Panel Operation menu functions The Front Panel Controller uses a 320 by 240 pixel LCD display with a set of six buttons above and a six below the display Across the top of the screen is a title bar with menu names each name aligns with one of the upper panel buttons The top corner buttons are used to scroll the menu titles Only four of eight possible menu names are displayed in the title bar at one time Press either lt gt button or the knob to display different menu titles Each of the four middle buttons are assigned to the menu title that aligns with it As the title menus scroll left or right these soft buttons are dynamically reassigned to the name below it The example pictured in Figure 3 1 shows the second button is the Main menu shown highlighted because it is selected the third button is a Status menu the fourth button is the Audio menu Not shown if system has no audio the fifth button is for the I O menu Near the top corners of the screen is a round symbol Wherever this is symbol is displayed indicates that the speed knob on the front panel may be used Matrix 3200 6400 Series Front Panel Version 1 02 Copyright 1999 Extron Electronics Figure 3 1 Using the top buttons with an FPC 1000 menu
45. t number and the words Break Away appear as the input name Plane breakaway cannot be created from the FPC 1000 but can be done using a PC or other control system through RS 232 programming Virtual Switching and Room Presets Virtual mapping cannot be set up from the FPC 1000 panel It must be done through RS 232 programming However the results of virtual configuration will show in the FPC 1000 menus Virtual switching is when for operational purposes the input or output numbers may not be the same as their physical numbers For example a large matrix switching system could include several different areas departments or rooms For everyday operations the training department may be independent from the sales department For these conditions each department would have its own set of audio video sources inputs and projectors monitors and recording devices outputs The users in one room know nothing of the equipment in another room because each have their own room presets that act as a virtual matrix switcher The training room could have inputs 1 4 and outputs 1 3 and the sales room could have inputs 1 5 and outputs 1 4 However output 1 in training is not output 1 in sales because different inputs and outputs are assigned to each room in a preset Extron Matrix 3200 6400 Series Switchers FPC 1000 User s Manual 3 6 Using the FPC 1000 Front Panel Controller Chapter 3
46. tments See Figure 3 13 The description information near the top below the title bar says Adjust LCD Backlight Contrast Time out Buttons at the bottom are for selecting one of these three adjustments Press one of the three options at the bottom and the name of the adjustment displays above a bar graph across the bottom of the LCD display to indicate the adjustment level LCD Contrast Use the scroll buttons lt gt or the speed knob to adjust the LCD contrast Observe the visible change in the display as well as in the position of the graphic indicator The adjustment takes place immediately with no Take and no confirmation LCD Back Light Use the scroll buttons 4 gt or the speed knob to adjust the LCD Back Light level Observe the visual change in the display as well as in the position of the graphic indicator The adjustment takes place immediately with no Take and no confirmation Menu Timeout xx Minutes Use the scroll buttons lt p gt or the speed knob to adjust the timeout for the menu back light The timeout value is displayed above the adjustment The range left to right is 1 90 minutes with No TimeOut at the far right Changes take place immediately with no Take and no confirmation To exit this LCD Adjustment menu select another menu from the title bar at the top of the screen There is no ESC button Extron Matrix 3200 6400 Series Switchers FPC 1000
47. to 0 seconds Only on Wideband units Warning Ca Take Audio Levels l l l Set all audio gain attenuation levels to 0 dB Only on systems with audio Factory Defaults Reset all of the above Use the scroll buttons or the speed knob to select one of the displayed five six or seven options from this menu This example shows Factory Defaults Press Take to reset the system to Factory Defaults e A warning message appears at this time asking for confirmation Press Take again only if you are sure you want to change the settings Extron Matrix 3200 6400 Series Switchers FPC 1000 User s Manual 3 16 Using the FPC 1000 Front Panel Controller Chapter 3 Status Menu Terminal Mode To get here from the Main Menu press Status Check Status Terminal Status Terminal mode allows the LCD display to monitor i RS 232 activity The function buttons at the bottom of L Piua the screen are Clear Pause Resume Hex ASCll and yew Status ESC There is a scroll bar along the left side of the Terminal screen with an indicator that moves upward as more monitor RS 232 activity data scrolls onto the display Remote keypade panels RX precedes information received from the host FF C test front panel TX precedes information sent to the host In ASCII mode as shown here the information appears as it is described in the RS 232 programming section of the Matrix 3200 6400 User s Manual A Status RAE TO A
48. tourner ni de la d sactiver D connexion de l alimentation Pour mettre le mat riel hors tension sans danger d connectez tous les cordons d alimentation de l arri re de l appareil ou du module d alimentation de bureau s il est amovible ou encore de la prise secteur Protection du cordon d alimentation Acheminer les cordons d alimentation de mani re ce que personne ne risque de marcher dessus et ce qu ils ne soient pas cras s ou pinc s par des objets R paration maintenance Faire ex cuter toutes les interventions de r paration maintenance par un technicien qualifi Aucun des l ments internes ne peut tre r par par l utilisateur Afin d viter tout danger d lectrocution l utilisateur ne doit pas essayer de proc der lui m me ces op rations car l ouverture ou le retrait des couvercles risquent de l exposer de hautes tensions et autres dangers Fentes et orifices Si le bo tier de l appareil comporte des fentes ou des orifices ceux ci servent emp cher les composants internes sensibles de surchauffer Ces ouvertures ne doivent jamais tre bloqu es par des objets Lithium Batterie Il a danger d explosion s ll y a remplacment incorrect de la batterie Remplacer uniquement avec une batterie du meme type ou d un ype equivalent recommande par le constructeur Mettre au reut les batteries usagees conformement aux instructions du fabricant Vorsicht Stromquellen Dieses Ger t sollte nur ber
49. tron s Matrix 3200 6400 Series FPC 1000 User s Manual 68 355 02 Rev A 08 89 Rev B 07 99 Rev C 01 02 add warning and MCP 1000 Written and printed in the U S A FCC Class A Compliance The user is cautioned that any changes or modifications not expressly approved by Extron Electronics could void the user s authority to operate the equipment per FCC regulations Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Note This unit was tested with shielded cables on the peripheral devices Shielded cables must be used with the unit to ensure compliance ii Matrix 3200 6400 Series Switchers FPC 1000 User s Manual Extron Matrix 3200 6400 Series Front Panel Controller User s Manual Chapter One Introduction to the FPC 1000 What is a an FPC 1000 Matrix 3200 6400 Series System Modules Features Introduction and Features FPC
50. uipo posee ranuras o orificios en su caja alojamiento es para evitar el sobrecalientamiento de componentes internos sensibles Estas aberturas nunca se deben obstruir con otros objetos Bater a de litio Existe riesgo de explosi n si esta bater a se coloca en la posici n incorrecta Cambiar esta bater a nicamente con el mismo tipo o su equivalente recomendado por el fabricante Desachar las bater as usadas siguiendo las instrucciones del fabricante Contents Chapter 1 Introduction and Features FPC 1000 Front Panel Controller Whatis an FRG 10007 cidcid adidas 1 1 Matrix 3200 6400 Series System Modules 0ooocoooccccnccccccnonnnnnnaccnnnnncccnonononnnnn cnn nano narran rana n rr narran 1 1 FPG 1000 FOatures OPORTO OPA O o e 1 2 PSCIIG AL OMS ec Fascia es canis Yet euk Sanit T T ites St case eebee see deteease teeta 1 3 Chapter 1 Illustrations Figure 1 1 An FPC 1000 shown as part of a Matrix 3200 6400 Series Switcher System 1 1 Figure 1 2 Matrix 3200 6400 Series Front Panel Controller mounted in a BME 1 1ccccssseeeeees 1 2 Chapter 2 Installing the FPC 1000 Installing the FPG VOQO coc a diia 2 1 Chapter 2 Illustrations Figure 2 1 An FPC 1000 mounted in a Matrix 3200 6400 Series Switcher BME cccccceee 2 1 Figure 2 2a Remove the Blank Panel 1 ccccccccccccecccssseeeceneeesseeeeeesssaeecedeeeseseeeeessiaseesenneseseseeeeteas 2 2 Figure 2 2b Connect the RJ Cable ooooocoocicccccoco
51. witching 1 Input A is being displayed by the output device and a request is received from a panel button or a program command 2 The RGB signals for input A are switched off causing the display screen to become blank The sync from input A is still on 3 The sync is switched from A to input B but not the RGB signals The screen is still blank as the new sync stabilizes 4 The RGB signals from input B are switched to the projector The image is stable because the projector has already locked onto the new sync Although this description may seem like a long delay it is only from 0 5 to 5 0 seconds depending upon the requirements of output device The Delay menu allows the delay time for each output to be set to match the output device The settings are for no delay 0 0 or a delay time of 0 5 to 5 0 seconds For the best results choose the shortest delay time that produces seamless switching Matrix 3200 6400 Series Switchers FPC 1000 User s Manual Extron Chapter 3 Using the FPC 1000 Front Panel Controller Delay Menu for Triple Action Switching Press any menu title button at any time to escape without making changes To get here from the Main Menu press e Delay Instruction message appears here gt Use option selections with buttons gt Figure 3 9 Delay menu not available with composite or S video De sta Set Switching Delay Tie law Select output Adjust 1
Download Pdf Manuals
Related Search
Related Contents
Operations Manual - ElectricalManuals.net Maytag MGD5600TQ1 User's Manual Samsung 2233RZ Felhasználói kézikönyv E5AN Temperature Controller User's Manual Guide de choix des autopiqueurs Dossier de presse - Théâtre du Rond Logitech 961-000376 surveillance camera Fujitsu ESPRIMO C710 PDFファイル Copyright © All rights reserved.