1. level connecting to S130 input 1 two wires for high level connecting to S130 input 2 2 Set the SIMCard Number in B side S130 as the first SMS Alarm number in A side S130 and modify the SMS Alert content as 1234CC 1234 stands for password to input 1 1234DD to input 2 So when Low level detected the A side S130 will send 1234CC command to B side S130 to switch ON the Pump when high level detected will send 1234DD to B side S130 to Switch OFF the Pump Means the A side alarm SMS message as the B side S130 Command 8 3 Install the Mainframe The mainframe should be installed in the position that person can not get it and there re with a power source as well as enough GSM signal coverage 8 4 Install the Speak and Microphone to the Mainframe The GSM SMS Controller allow the authorized users call in to create two way voice communication also when the system alarm the authorized number can listen in the on site sounds While you install the Microphone and Speaker please make sure keep it away from the GSM SMS Controller at least 1meters and far from the siren if possible 9 Technical specifications Rated Voltage 12VDC 2A Page 13 of 14 Communica Pty Ltd Page 130f 14 Ver1 2 File No KPS13011 Working temperature 10 C 60 C Storage temperature 20 C 60 C Relative humidity 10 90 No condensation GSM frequency 900 1800 1900MHZz or 850 900 1800 1900Mhz Communication protocol GSM PHASE 2 2 include data servi
2. the setup will be failure IStep5 Please setup the GSM SMS Controller parameters IStep6 After you finished the setup then press Download button then switch on the GSM SMS controller after 2Seconds it will alert the Setup successful If it hasn t prompted the setup successful then means the setup is failure please check the Com port and USB connection You can change the Com Port to try it one by one if the Communication LED sign is green after you press the Download then means the Com port is correct otherwise it is incorrect please use the dropdown menu to change it Power off the unit then remove the USB cable Then power on the Unit to finish the setup Page 7 of 14 Communica Pty Ltd Page 7o0f 14 Ver1 2 File No KPS13011 If it hasn t prompted the setup successful then means the setup is failure please check the Com port and USB connection then try to repeat the Step1 Step6 again SEEE ee _ Please add the country code e g 86 or 0086 in China When alarm the unit will call these numbers one by one after sent out SMS Alarm message Please see below tips Please add the country code e g 86 or 0086 in China When alarm the unit will send related Digital Input SMS Alert Content to these numbers one by one firstly Input SMS These words or sentences will be sent to the SMS Alert Numbers once the related inputs Select it to make siren sound and alarm link output relay close for 4minutes when
3. 2 of 14 Communica Pty Ltd Page 20f14 Ver1 2 File No KPS13011 1 Brief introduction The GSM SMS Controller is a very simple device which can be used for authorized door access controlling gates switching of remote equipments car parking systems Actually the GSM SMS Controller can be used in places which require turning ON OFF your system machines and equipment remotely with a SMS text from your mobile phone and protect your assets Moreover the GSM SMS Controller with multi digital inputs for digital inputs when any one of the inputs triggered will start the siren or switch on the light automatically in the meanwhile the GSM SMS Controller will send SMS Alert the to owners immediately This is very useful if you need protect your assets with low cost solution The GSM SMS Controller suitable for below applications SMHNAAARwWNDY gt Security Alarm System applications Supervision and monitoring alarm systems Automatic monitoring system Vending Machines security protection Pumping Stations Tanks Oil or Water levels Buildings and Real Estate Weather Stations River Monitoring and Flood Control Oil and gas pipelines Corrosion protection Temperatures water leakage applications Wellheads boat vehicle Energy saving street lights control system Valve controls Transformer stations Unmanned machine rooms Control room application Automation System M2M GSM Access Control Sys
4. INS Digital input 5 connect to one wire of the wired Detector GND Ground point connect to another wire of the wired Detector or 12VDC Digital input 6 connect to one wire of the wired Detector Digital input7 connect to another wire of the wired Detector GND Ground point connect to another wire of the wired Detector Digital input 8 connect to one wire of the wired Detector Built in 240VAC S3A rated relay output connect to the device positive electrode OR Built in 240VAC S3A rated relay output connect to the device negative electrode R2 Built in 240VAC S3A rated relay output connect to the device positive pole O RR Built in 240VAC S3A rated relay output connect to the device negative electrode 5 Features 1 relay output 240VAC 3A can be switched ON OFF by sending a SMS text 1 relay output 240VAC S3A can be switch on 4minutes if any inputs triggered 2 4 8 Alarm logic inputs NC or NO and EOL is optional 3 SMS Alert numbers and 5 auto dial numbers can accept to the alarm message Two way voice communication by external microphone and speaker oS oa Se iy Supports armed disarmed inquiry status switch on or off relay output by SMS Commands Page 5 of 14 Communica Pty Ltd Page 5of14 Ver1 2 File No KPS13011 7 Password protected prevents unauthorized user 8 Can be set up and programmed from PC Programmer by USB cable 9 Time stamped alarm messages 10 Backup rechargeable battery
5. be in short circuited mode NO Type Sensor 8 3 Typical application One of the typical application of the GSM SMS Controller is for automatically water tank monitoring and control solution Please help to see below diagram Also it can use to lots of other solutions E g 1 Security Alarm System applications 2 Supervision and monitoring alarm systems 3 Automatic monitoring system 4 Vending Machines security protection 5 Pumping Stations Tanks Oil or Water levels 6 Buildings and Real Estate 7 Weather Stations River Monitoring and Flood Control 8 Ojl and gas pipelines Corrosion protection 9 Temperatures water leakage applications Wellheads boat vehicle 10 Energy saving street lights control system Valve controls 11 Transformer stations 12 Unmanned machine rooms Control room application 13 Automation System M2M 14 GSM Access Control System GSM Gate Opener etc Page 12 of 14 Communica Pty Ltd Page 120f14 Ver1 2 File No KPS13011 Tank Water Level Monitoring Solution When the A side 5130 detect the water level is high then send SMS to B side 130 to Switch off the Pump High Level When A side 5130 received the Low level signal from the water level sensor then send SMS Low Level command to B side 130 to switch ON the Pump Explanation 1 Use the water level sensor WL 03 to detect the water level it can detect the low level and high level two wires for low
6. inside can work for 24hours when power off 11 Can be operated from anywhere no distance limit 12 Based on GSM Network applied to many applications 6 Settings The GSM SMS Controller is for user friendly design The user can setup it by the PC programmer through USB cable The GSM SMS Controller can not setup by SMS Commands 1 In order to forbidden the intruders power off the unit we equipped the power switch inside it is nearby the SIMCard socket please pay attention to it and dont tell others of this Turn it towards inside is off turn it towards outside is on And when setup the unit please put the Setting switch to SET position after setup switch it to WORK Position Please see below photo i 5 E i r Sw tee jia ar its P be ea ie l 2 Please insert the SIMCard firstly and install the GSM Antenna please power on to check the LEDs can work or not then power off it before you program it by PC Programmer 3 The default password is 1234 you can modify it by enter the new password in the PC Programmer 4 Two way communication While the authorized users incoming call the GSM SMS Controller unit will automatically answer the call then the two way voice communication will be created If you want to test the two way voice communication please make sure the other phone is away from the GSM SMS Controller unit at least 500meters Otherwise the near cross will make lots of noise interference P
7. the unit Select it to set the unit to arm mode once power on in this case any sensor triggered will alarm The system will send out the preset SMS text to SMS alert numbers and dial the Alarm target phone numbers one by one in the meantime the siren will sound 1 minutes and the alarm link output relay will switch on 4 minutes Otherwise the system will in disarmed mode after power on Fill it to setup the Report time gap Range O 240Hours The unit will automatically send its status to SMS alert numbers according to this setting NC Normal Close NO Normal Open EOL End of Line Means must be connection in series with a 2 2K resistor between the GSM SMS controller and digital detector Notice 1 In some GSM operators they use different SMS protocols if the unit can t return the SMS confirmation is normally It is not product problem Also you can try to add the country code before the number see the below settings Page 8 of 14 Communica Pty Ltd Page 8o0f 14 Ver1 2 File No KPS13011 For example In China the country code is 86 or 0086 The user cell phone number is 13570810254 and has been assigned as a SMS Alert number the simcard number in the panel is 13512345678 Problem 1 Alarm but the user hasn t received the SMS Alert Solution Please plus the country code while you setup the 13570810254 as SMS Alert number means setup 8613570810254 to instead SMES SRAM EAS Problem m user number can receive
8. Remote switching machines with a SMS text from your mobile phone Remote Monitoring your assets in the worldwide by your mobile Phone GSM SMS Alarm Unit GSM SMS Controller 1 USB Port 2 Relay Outputs 2 4 8 Digital Inputs CER GSM SMS Controller GSM SMS Alarm Unit GSM COMCATOR 2X2 USB 4X2 USB 8X2 USB User Manual Ver 1 20 Date Issued 2010 09 14 Page 1 of 14 Page 10f14 Ver1 2 File No KPS13011 Table of contents l Brief introduction 3 2 Safety Directions 3 3 Standard Packing list 4 4 Physical Layout 4 Se UI Sr aan gr es eee s 6 Settings 6 7 Operation g 8 Installation 9 9 Technical specifications 13 10 Quality Warranty 14 11 Trouble Shooting Guide 14 Thi
9. age 6 of 14 Communica Pty Ltd Page 6of14 Ver1 2 File No KPS13011 The PC Programmer Interface GSE SES Controller PC Programmer 1 40 ma x mE Attention Please switch onthe unitatter you press Download button Alarm target phone num Digital Input SMS Alert Contents Telephone Input 1 Wired input 1 sensor alarm Telephones Input 2 wired input 2 sensor alarm Telephones Input 3 Wired input 3 sensor alarm Telephoned ee Sate Input 4 Wired input 4 sensor alarm Telephone5 Re Input S wired input 5 sensor alarm SMS Alert Munmbers Input E Wired input 6 sensor alarm Recipients Recipients Input Wired input f sensor alarm Recipients3 Inputa wired input 8 sensor alarm Other Settings l lSound laim Powerdown Alert GSM JammerAlet ARM Password 1234 Report Time 24 0 240H Alarm Delay Time 1 1 90 Digital Input Type NC E Com Port comi e Download Upload Save Read Stop Serial Port Status io Communi cations ee Information Please following the below steps one by one to setup it otherwise you can not setup it successfully Step1 Please install the USB Driver to the computer from the CD firstly IStep2 Please insert the SIMCard into the GSM SMS Controller carefully Step3 Please running the PC Programmer needn t installed it IStep4 Please connect the GSM SMS Controller to the computer through USB cable but please don t switch on the GSM SMS Controller otherwise
10. ce Digital inputs 2 4 8 Backup Rechargeable Battery 24Hours in standby mode Related Voltage of the Output Relay 3A 240V AC Net Weight 0 60Kg 10 Warranty 1 This system is warranted to be free of defects in material and workmanship for one year from the date of purchase 2 This warranty does not extend to any defect malfunction or failure caused by abuse or misuse by the Operating Instructions In no event shall the manufacturer be liable for any alarm system altered by purchasers 11 Trouble Shooting Guide PROBLEM POSSIBLE SOLUTION GSM Module Backup battery with low voltage 1 Please contact the AC Power initialization GSM Module connection loose 2 Please help to take the panel to a mobile phone repairmen store and failed in transportation then ask the engineer to check the GSM Module socket and the GSM 2 GSM Signal is too weak Module connection Please change another position to install the alarm panel Automatically 1 Backup battery with low Please help to contact the AC Power Restart oe False Alarm PIR Motion sensor installation Please see the PIR Motion sensor installation user manual carefully incorrect Please check the detector NC NO type and you re sure connect a 2 NC NO EOL is incorrect 2 2K Resistor in series in the un use input ports Alarm without 1 GSM Operator communication SMS Dial protocol No action 2 Haven t setup SMS Alert Auto after send dial Numbers SMS 3 Caps Lock lett
11. d sirens please help to test the system firstly including wired sensor power supply gsm signal etc 8 1 Insert SlMcard into Control Unit In the backside of the control unit please install the GSM SIM ward BS The GSM ANT must be Vertical installation to ensure it in good working condition 8 2 Connecting the Wired Sensors and Electricity equipments Please help to see below wiring diagram then fixed the related wired sensors the sensors connect to the related digital inputs 1 Please setup the NC NO EOL type in the PC Programmer correctly 2 If you setup the Nodes type as NC Default the no use inputs must be with short circuited by wires and the sensor type must be NC Please see below diagram 3 If you setup the input type as EOL then please contact a 2 2K Resistor in series with every inputs if you don t connect the sensor to the inputs please connect a 2 2K Resistor in series to instead of it Moreover only the digital detector is NC type Page 10 of 14 Communica Pty Ltd Page 100f14 Ver1 2 File No KPS13011 4 NS 5 6 7 8 can use in EOL mode Please see the below diagram If you setup the input type as NO then please keep the two points of the inputs by free and the sensor type must be NO Please see the below diagram The Unit built in 240VAC 3A rated relay Please make sure the power cord rated while you connect to equipment device also please make sure the power consumption is less t
12. ers in the SMS Please setup the SMS Alert Numbers Please help to see the sample of setup the telephone numbers Please check the commands with CAPS LOCK and correct format Also please help to change another GSM Operator SIMCard to test it Page 14 of 14 Communica Pty Ltd Page 140f 14 Ver 1 2 File No KPS13011
13. han 250W for long time working If you need heavy equipment please connect an additional relay The R1 and R1 is for alarm link output when the system alarm will close for 4 minutes the rated output power is 700W If you need heavily equipment please connect an additional relay The R2 and R2 is the relay output for SMS Command CC is close DD is open EE is inquiry the status The 12VDC is for the Detectors if the detectors need 12VDC power then please contact it to the 12VDC The 12VDC power is from external power not from backup battery So please note When AC power failure the 12VDC point will no power supply NC Type Connection iii fo Power Siren 12V IN1 GND IN2 IN3 GND IN4 12V IN5 GND IN6 IN7 GND IN8 R1 R1 R2 R2 Dizovac O TATE a TE N 220VAC G E G Ee ET p Cos fi T i 1 The two 12V are power source for wired sensors 2 The R1 R1 is the alarm link output relay 3 The R2 R2 is a seperate output relay which can be switched ON OFF by SMS Commands 4 The no use inputs must be keep in short circuited by wires Page 11 of 14 Communica Pty Ltd Page 110f 14 Ver 1 2 File No KPS13011 NO Type Connection O Power Siren 12V IN1 GND IN2 IN3 GND IN4 12V IN5 GND IN6 IN7 GND IN8 R1 R1 R2 R2 1 We re strongly suggest not use this connection type 2 Inthis connection type all of the wired sensors must be NO and the no use inputs must be free can not
14. s handbook has been designed as a guide to the installation and operation of GSM SMS Controllers Statements contained in the handbook are general guidelines only and in no way are designed to supersede the instructions contained with other products We recommend that the advice of a registered electrician be sought before any Installation work commences Communica Pty Ltd its employees and distributors accept no liability for any loss or damage including consequential damage due to reliance on any material contained in this handbook Communica Pty Ltd its employees and distributors accept no liability for GSM Network upgrading or SIM Card upgrading due to the technology specifications contained in this handbook Model List O sw 2 oaia 1 Aarm Link roley output 1 separate relay output or SMS Commands sao Dainas len Lrk ay output 1 separate relay output for SMS Commands TSS e Diels Alem Link relay output 1 separate relay output for SMS Commands SMS Command List SMS COMMAND Functions amp Actions OO A To arm the system in this case any sensor triggered will alarm BB To disarm the system in this case any sensor triggered will not alarm To switch ON the separate relay output pb To switch OFF the separate relay output EE Inquiry the GSM SMS Controller Status The commands should plus Password the format is Password SMS Command i e if the password is 1234 then you can send to arm to disarm Page
15. tem GSM Gate Opener etc 2 Safety Directions Safe Startup Do not use GSM SMS Controller when using GSM equipment is prohibited or might bring disturbance or danger Interference All wireless equipment might interfere network signals of GSM SMS Controller and influence its performance Avoid Use at Gas Station Do not use GSM SMS Controller at a gas station Power off GSM SMS Controller when it near fuels or chemicals Page 3 of 14 Communica Pty Ltd Page 30f14 Ver1 2 File No KPS13011 Power it off near Blasting Places Please follow relevant restrictive regulations Avoid using the device in blasting places Reasonable Use Please install the product at suitable places as described in the product documentation Avoid signal shielded by covering the mainframe lt B Use Qualified Maintenance Service Maintenance can be carried out only by qualified maintainer 3 Standard Packing List Control Unit X1 GSM ANT X1 User Manual X1 CD Connectors AC DC Adaptor X1 Optional Accessories Wired Sensors PIR Motion Sensor Glass Break Sensor Magnetic Window Sensor Temperature Sensor Infrared Beam Fence Vibration sensor Water level sensor Siren etc 4 Physical Layout 4 1 Control Unit physical layout LED Instruction GSM RELAY STATUS ALARM GSM GSM Module indicator registering will quickly flick registered successful will slowly flick RELAY Output relay indicator when any output relay closed it
16. the SMS Alert message from alarm panel but the alarm panel can not receive the commands from the user number Solution Please add country code to the SIMCard number in the alarm panel Means send sms commands to ites gi Solution 3 When you use cell phone dial another one what number it will be displayed then you can set the displayed number as dial numbers when you use cell phone send SMS to another cell phone what number it will be displayed then you can set the displayed number as SMS Alert number just use the to replace the 00 also you can try the OO 7 Operating Instructions he User can Arm Disarm Inquriy system status Switch on or off the independent output relay by sending SMS to the Control unit The SMS Commands are below The system will carry out the commands immediately with no delay after the Control Unit receive this SMS command 7 1 Armed XxxxAA Example Return SMS 7 2 Disarm XXXXBB Example Return SMS 7 3 Switch On the independent output relay XXXXCC Example Return SMS Page 9 of 14 Communica Pty Ltd Page 90of14 Ver 1 2 File No KPS13011 7 4 Switch OFF the independent output relay xxxxDD Example Return SMS 7 5 Inquiry System Status XXXXEE Return SMS The Output relay status in the Return SMS is the independent output relay status It is not the alarm link Output Relay Status 8 Installation Before installing the control unit and sensors an
17. will be on when relay opened will be off STATUS Arm Indicator on is armed off is disarmed Alarm Alarm Indicator on is alarming off is normally Interface 1 Instruction Q GSM ANT For listening in the sounds around the GSM SMS Controllers while alarm the Microphone is needn t power is the same type for the computer For two way voice communication When the authorized number dial in the unit will check the incoming number if matched then can create two way voice communication GSM ANT Connect the GSM ANT if the GSM signal is not strong then please change the 3dB GSM ANT USB Connect to the computer for setup the unit parameters Page 4 of 14 Communica Pty Ltd Page 4of14 Ver1 2 File No KPS13011 Interface 2 Instruction POWER External Power Connector Connectto 2A 12V DC power through AC DC Adaptor o c SIREN Will start for 60seconds when alarm The siren or strobe siren should be lt 12V DC O4e 12VDC 1A power output for wired detectors IN Digital input 1 connect to one wire of the wired Detector GND Ground point connect to another wire of the wired Detector or 12VDC O N2 Digital input 2 connect to one wire of the wired Detector INS Digital input 3 connect to one wire of the wired Detector GND Ground point connect to another wire of the wired Detector Digital input 4 connect to one wire of the wired Detector 12VDC 1A power output for wired detectors