Home

User Manual - Philips Lighting

image

Contents

1. Special Cleaning and Care Insturctions Being a solid state fixture and unlike most fixtures the SL ParBlazer 100 UV requires very little routine maintenance by the user This section covers portions ofthe luminaire that can be removed for cleaning The SL ParBlazer 100 UV requires special care when it comes to cleaning the front lens cover Additional care needs to be taken with any plastic components because they are much easier to scratch or damage than glass Lint free lens tissue Lint or powder free gloves Reagent grade isopropyl alcohol A mild soap solution Note Reagent grade isopropyl alcohol is good to use on the SL ParBlazer 100 UV plastic optics with anti reflection coatings If the lens is still dirty after using isopropyl alcohol for instance if fingerprints or oil is just redistributed and not cleaned off the optic then a mild soap and water solution can be used to gently wash the lens Repeat the cleaning with isopropyl alcohol to eliminate streaks and soap residue WARNING Under no circumstances should ammonia based cleaners acetone or other harsh solvents be used on or near the SL ParBlazer 100 UV These types of cleaners or solvents can permanently damage the optics or housings ofthe fixture If you have any questions regarding the use or care of your SL ParBlazer 100 UV please contact Showline technical support or your local Authorized Dealer Front Lens Cleaning To clean
2. Figure 10 SL ParBlazer 100 UV Master Slave Configuration Shewline 12 Master Slave Operational Mode SL ParBlazer 100 UV Installation amp User s Manual 5 Dimming Curve Selection Through the menu you are able to select one of four dimming curves Linear Curve e PL Curve e S Curve e Square Curve Linear Curve Lumen Output 5 o DMX Value Lumen Output DMX Value Output DMX Value DMX Value PL Curve follows the dimming curve of Philips Selecon PL series LED luminaries Square Curve 3 E o Lumen Output DMX Value Lumen Output DMX Value Lumen Output DMX Value DMX Value Figure 9 SL ParBlazer 100 UV Luminaire Dimmer Curves Shewline Dimming Curve Selection 13 Installation amp User s Manual SL ParBlazer 100 UV DMX CONTROL This section contains information for operating the luminaire using DMX control in 8 bit mode and16 bit mode For Menu options and detailed information see LCD Display and Menu System on page 9 Note These tables assume a DMX start address of 1 When a different starting address is used this address becomes channel function and the other functions follow in sequence 1 SL ParBlazer 100 UV DMX Mapping 8 Bit Mode Table 3 provides DMX channel ma
3. DEVICE LABEL 0x0082 n FACTORY DEFAULTS 0 0090 LANGUAGE CAPABILITIES 0x00A0 LANGUAGE 0 00 0 SOFTWARE VERSION LABEL 0 00 0 m SOFTWARE VERSION ID 0 00 1 SOFTWARE VERSION LABLE 0x00C2 Category DMX512 Setup DMX PERSONALITY 0 00 0 DMX PERSONALITY DESCRIPTION 0 00 1 m B DMX START ADDRESS 0 00 0 Required if device uses DMX Slot a SLOT INFO 0x0120 im SLOT DESCRIPTION 0x0121 L DEFAULT SLOT VALUE 0x0122 Category Sensors 0x02xx SENSOR DEFINITION 0x0200 a SENSOR VALUE 0x0201 RECORD SENSORS 0x0202 Category Dimmer Settings 0x03xx FUTURE USE Category Power Lamp Settings 0x04xx DEVICE HOURS 0x0400 LAMP HOURS 0x0401 LAMP STRIKES 0x0402 LAMP STATE 0x0403 LAMP ON MODE 0x0404 DEVICE POWER CYCLES 0x0405 Category Display Settings 0x05xx DISPLAY INVERT 0x0500 L DISPLAY LEVEL 0x0501 Category Configuration 0x06xx 0 0600 TILT INVERT 0x0601 PAN TILT SWAP 0x0602 REAL TIME CLOCK 0x0603 Category Control 0x10xx L IDENTIFY DEVICE 0x1000 L RESET DEVICE 0 1001 SL ParBlazer 100 UV RDM Shewline SL ParBlazer 100 UV Installation amp User s Manual Table 7 SL ParBlazer 100 UV RDM Parameters IDs Fass d 4 RDM Parameter IDs Value Comment Implemented POWER STATE 0 1010 PERFORM SELFTEST 0x1020
4. L SELF TEST DESCRIPTION 0 1021 CAPTURE PRESET 0 1030 PRESET PLAYBACK 0 1031 Table 8 SL ParBlazer 100 UV RDM Parameter Status IDs Manufacturer Specific messages are the range of 0x8000 OXFFDF Each Manufacturer specific Status ID shall have a unique meaning which shall be consistent across all products having a given Manufacturer ID See Table B 2 ANSI E1 20 2010 Status ID Message Value Data Value 1 Data Value 2 Status ID Description 8100H 00H ALL OK Table 8 SL ParBlazer 100 UV RDM Parameter Specific PIDs Get Set M Allowed Allowed RDM Parameter IDs Type Length Unit Prefix Min Max Default Description Category Manufacturer Defined PIDs Range is 0x80000 0xffdf See ANSI E1 20 2010 Standard Table A 3 a a 8A00H U8 1 NONE NONE 0 100 100 DIMMER a a 8AAIH S8 1 DB NONE 0 3 0 Dimming Curve a 8A0CH 58 1 DB NONE 0 3 0 DMX FAIL MODE Shewline SL ParBlazer 100 UV RDM 1 Installation amp User s Manual SL ParBlazer 100 UV CLEANING AND CARE 18 WARNING cleaning should be performed with power completely removed from luminaire Never remove protective covers when luminaire is powered Wear appropriate protective eye wear and gloves when cleaning the fixture All service and maintenance other than described herein should be performed by a qualified technician or Authorized Service Center
5. CE Marked International models IP65 Note Common model specifications shown For specific model specifications features and accessories refer to the product specification sheet for more details Shewline OPERATIONAL SPECIFICATIONS 19 Installation amp User s Manual SL ParBlazer 100 UV 2 Luminaire Dimensions 20 LUMINAIRE DIMENSIONS S how n e SL ParBlazer 100 UV Installation amp User s Manual NOTE Shewline Showline Dallas 10911 Petal Street Dalls TX 75238 Tel 1 214 647 7880 Fax 1214 647 8031 Asia Unit C 14 F Roxy Industrial Centre No 41 49 Kwai Cheong Road Kwai Chung N T Hong Kong Tel 852 2796 9786 Fax 852 2798 6545 Auckland 19 21 Kawana Street Northcote Auckland 0627 New Zealand Tel 64 9 481 0100 Fax 64 9 481 0101 Europe Rondweg zuid 85 Winterswijk 7012 JD The Netherlands Tel 31 0 543 542516 2015 Philips Group
6. near gas or electric heaters Equipment should be mounted in locations and at heights where it will not readily be subject to tampering by unauthorized personnel d The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition Do not use this equipment for other than intended use f Refer service to qualified personnel SAVE THESE INSTRUCTIONS WARNING You must have access to a mains circuit breaker or other power disconnect device before installing any wiring BE sure that power is disconnected by removing fuses or turning the mains circuit breaker off before installation Installing the device with power on may expose you to dangerous voltages and damage the device A qualified electrician must perform this installation WARNING Refer to National Electrical Code and local codes for cable specifications Failure to use proper cable can result in damage to equipment or danger to personnel WARNING This equipment is intended for installation in accordance with the Nation Electric Code and local regulations It is also intended for installation in indoor applications only Before any electrical work is performed disconnect power at the circuit breaker or remove the fuse to avoid shock or damage to the control It is recommended that a qualified electrician perform this installation Additional Resources for DMX512 For more information on installing DMX512 control systems the followin
7. sold separately Safety Cable Anchor Point SAFETY CABLE Is sold separately and recommended for all hanging installation and may be required by national and local codes Use the safety cable anchor point for this fixture Figure 6 Mounting the Fixture Hanging Applications Floor Mounting The SL ParBlazer 100 UV are designed to sit directly on its split yoke assembly in a floor installation application When used in this type of application be sure to leave enough space around the luminaire to allow proper uninterrupted airflow for cooling and movement Mounting Luminaire S hewl SL ParBlazer 100 UV Installation amp User s Manual OPERATION AND PROGRAMMING 1 LCD Display and Menu System The ProTron LED Luminaire s LCD Display and Menu System provides local control for accessing the following fixture s settings e DMX Address e Manual Dimming e DMX Personality e Dimming Curve e DMX Fail e Default Setting e Temperature e Firmware e RDMUID Note If there are multiple luminaires in a system changes would need to be made at each LCD Menu as desired Upon power up the LCD will display the main screen showing menu of ProTron LED user can use lt and gt to select then enter the desired function menu LCD Display EXIT Button CX CXS CHECK Button LEFT Arrow Button RIGHT Arrow Button ESC lt gt O
8. 0 UV DMX Mapping refer to DMX CONTROL on page 14 DMX512 from console or control device DMX512 out from first DMX512 out to the next to second luminaire luminaire or DMX512 controlled device DMX512 Conections DMX512 Signal XLR Pin Color Common Drain 1 1 512 2 White DMX512 3 Red Note Remaining pins on each connector are not used Figure 5 SL ParBlazer 100 UV DMX512 Connections Shewline Installation amp User s Manual SL ParBlazer 100 UV 4 Mounting Luminaire Truss Hanging Applications The SL ParBlazer 100 UV is provided with the ability to hang via truss hooks clamps etc sold separately Simply attach hook clamp etc to the SL ParBlazer 100 UV yoke through the provided M12 holes It is recommended and may be required by local and national safety codes to use and install a safety cable sold separately as illustrated in Figure 6 When hanging the fixture be sure to leave enough space around the luminaire to allow proper uninterrupted airflow for cooling and movement Refer to Luminaire Dimensions on page 20 for spacing dimensional requirements Note Mounting hooks clamps safety cables etc are sold separately or by others Truss Hook or Clamp
9. EANING AND CARE Special Cleaning and Care Instructions Front Lens Cleaning Service and Maintenance TECHNICAL SPECIFICATIONS Operational Specifications Luminaire Dimensions 2 Table of contents Inside Front Cover 00 N tn tA 10 11 13 14 14 14 15 18 18 18 19 20 Shewline SL ParBlazer 100 UV Installation amp User s Manual PREFACE 1 About this Manual The document provides installation and operation instructions for the following products e SL ParBlazer 100 UV Luminaire Please read all instructions before installing or using this product Retain this manual for future reference Additional product information and descriptions may be found on the product specification sheet Note The SL ParBlazer 100 UV luminaire works from 100 to 240 VAC auto ranging 2 Included Items Each SL ParBlazer 100 UV luminaire includes the following items SL ParBlazer 100 UV Luminaire Quick Start Guide US Market 3 AC Input cable 1750mm For US Canada and Latin America market only 1 AC Output cable 1000mm For US Canada and Latin America market only m es 8 DMX Input cable 1000mm DMX Output cable 1000mm International Market AC Input cable 1500mm For International market only diem AC Output cable 1000mm F
10. K Figure 7 LCD Display and Menu System S howl n e OPERATION AND PROGRAMMING 9 Installation amp User s Manual SL ParBlazer 100 UV 2 LCD Display and Menu System Operation The LCD Display Menu system consists of several categories Use the Menu Buttons to access and make changes to the menu items When the desired menu item is reached press the desired Menu Button to display the menu options and to navigate and configure the menu options as required To navigate and access menu settings selections Step 1 Make sure luminaire is powered and turned on Step 2 Press the desired button as shown in Figure 8 to access menu categories Step 3 Use LEFT RIGHT arrow buttons to navigate through the various options and settings Step 4 Make changes as desired Press CHECK MARK OK button to accept changes EXIT Button C X CHECK MARK OK Button LEFT Arrow Button RIGHT Arrow Button Figure 8 LCD Display and Menu System 10 LCD Display and Menu System Operation S h Ow n e SL ParBlazer 100 UV Installation amp User s Manual 3 SL ParBlazer 100 UV Menu Tree DMX Address 001 512 Manual Dimming 000 100 MX Personality DMX 8Bit DMX 16Bit imming Curve Linear Curve Square Curve S Curve PL Curve DMX Fail OFF Last Hold Default Setting Yes 55 oC Temperature Firmware Rev1 00 RDM UID 0x405101020304 Figure 9 SL ParBlazer 100 UV Menu Tree 2 _
11. MANUAL USEI TALLATION amp INS Shewline SL ParBlazer 100 UV Showline Offices Showline Dallas Showline Auckland 10911 Petal Street 19 21 Kawana Street Dallas TX 75238 Northcote Auckland 0627 U S A New Zealand Tel 214 647 7880 Tel 64 9 481 0100 Fax 214 647 8030 Fax 64 9 481 0101 Showline Europe Showline Asia Marssteden 152 Unit C 14 F Roxy Industrial Centre Enschede 7547 TD No 41 49 Kwai Cheong Road The Netherlands Kwai Chung N T Hong Kong Tel 31 53 4500424 Tel 852 2796 9786 Fax 31 53 4500425 Fax 852 2798 6545 Website www philips com showline The material in this manual is for information purposes only and is subject to change without notice Showline assumes no responsiblitity for any errors or omissions which may appear in this manual For comments and suggestions regarding corrections and or updates to this manual please visit the Showline website at www philips com showline or contact your nearest Showline office El contenido de este manual es solamente para informaci n y est sujeto a cambios sin previo aviso Showline no asume responsabilidad por errores o omisiones que puedan aparecer Cualquier comentario sugerencia o correcci n con respecto a este manual favor de dirijirlo a la oficina de Showline m s cercana Der Inhalt dieses Handbuches ist nur f r Informationszwecke gedacht Aenderungen sind vorbehalten Showline uebernimmt keine Verantwortu
12. UV 0x2030 Table 6 SL ParBlazer 100 UV RDM UID MSB of ESTA LSB of ESTA MSB of LSB of MSB of LSB of 50H 41H Unique Seq Unique Seq Unique Seq Unique Seq Table 7 SL ParBlazer 100 UV RDM Parameters IDs RDM Parameter IDs Value Comment Implemented Category Network Management DISC UNIQUE BRANCH 0x0001 DISC MUTE 0x0002 DISC UN MUTE 0x0003 PROXIED DEVICES 0 0010 PROXIED DEVICES COUNT 0 0011 COMMS STATUS 0x0015 Category Status Collection QUEUED MESSAGE 0 0020 STATUS MESSAGES 0x0030 STATUS ID DESCRIPTION 0x0031 m CLEAR STATUS ID 0x0032 m SUB DEVICE STATUS REPORT THRESHOLD 0x0033 Category RDM Information 0x0050 Support required only if SUPPORTED PARAMETERS supporting Parameters beyond the minimum required set PARAMETER DESCRIPTION 030051 pude SUPPORTED PARAMETERS message Shewline SL ParBlazer 100 UV RDM 15 Installation amp User s Manual SL ParBlazer 100 UV Table 7 SL ParBlazer 100 UV RDM Parameters IDs Nas ed RDM Parameter IDs Value Comment Implemented Category Product Information DEVICE INFO 0 0060 m PRODUCT DETAIL ID LIST 0x0070 DEVICE MODEL DESCRIPTION 0 0080 m MANUFACTURER LABEL 0 0081 B
13. __ _ _ _ 5 hewl n e SL ParBlazer 100 UV Menu Tree 11 Installation amp User s Manual SL ParBlazer 100 UV 4 Master Slave Operational Mode The Master Slave Operational Mode allows one SL ParBlazer 100 UV to act as the Master luminaire and all other connected luminaires are controlled by this luminaire When a luminaire is set to Slave mode it will only listen to and follow any commands sent from a Master luminaire Only one Master luminaire is allowed in this type of operation To setup a master slave network Step 1 Setthe first device in the DMX512 chain to Master Mode through the luminaire s menu system Step 2 Set all other connected luminaires to Slave Mode Step 3 The master luminaire can be controlled via DMX512 RDM or through standalone operation self contained network utilizing on board effects The slave luminaires will mimic the master luminaire s operation in all cases Note For more information on DMX512 networking and systems refer to Additional Resources for DMX512 on page 1 For SL ParBlazer 100 UV DMX Mapping refer to DMX CONTROL on page 14 Master luminaire Slave luminaire Slave luminaire DMX512 from console or control device DMX3512 out from first DMX5 12 out to the next to second luminaire luminaire or DMX512 controlled device
14. cted to an AC source the luminaire operates 100 to 240 volts AC 10 auto ranging The luminaire contains an auto ranging power supply Each luminaire can draw up to 100 Watts WARNING The maximum amount of fixtures that may be daisy chained is A 10 luminaires 100 120VAC or B 23 luminaires 230 240VAC 15 Amps Table 1 SL ParBlazer 100 UV Voltage VAC vs Current Voltage AC Total Current A Voltage AC Total Current A 100 1 00 180 0 56 110 0 91 190 0 53 120 0 84 200 0 50 130 0 77 210 0 48 140 0 71 220 0 45 150 0 67 230 0 43 160 0 63 240 0 42 170 0 59 Note For wiring of AC input connector refer to Connecting SL ParBlazer 100 UV to AC Power on page 6 Connecting Power Luminaires can be powered in one of two ways e Direct connection to an AC power source using an AC input cable For wiring ofthe AC input connector refer to Connecting SL ParBlazer 100 UV to AC Power on page 6 e Connection from the AC output of another SL ParBlazer 100 UV When using this method it is very important not to connect any other type of equipment WARNING Only connect other SL ParBlazer 100 UV luminaires to the AC Output Thru connector of SL ParBlazer 100 UV luminaire Shewline Wuuls onandsetUP 5 Installation amp User s Manual SL ParBlazer 100 UV Connecting the SL ParBlazer 100 UV to AC Power Table 2 describ
15. es how to connect power to your SL ParBlazer 100 UV Field wiring of the SL ParBlazer 100 UV LED Luminaire is straight forward A total of 3 wires conductors need to be brought to the luminaire The following wiring scheme is required AC Input Table 2 SL ParBlazer 100 UV AC Input Output Connections Wire Color Purpose Brown Main Line 100 to 240VAC Blue Neutral Green Yellow Ground Earth Luminaire 6 Connecting SL ParBlazer 100 UV to AC Power AC Output Figure 3 SL ParBlazer 100 UV AC Input amp Output Connections Shewline SL ParBlazer 100 UV Installation amp User s Manual 3 Connecting to the DMX512 Network Basic DMX512 installation consists of connecting multiple SL ParBlazer 100 UVs together up to 32 luminaires in daisy chain fashion A cable runs from the control console or DMX512 control source to the DM X connector on the first SL ParBlazer 100 UV Another cable runs from the other DMX connector on the first luminaire to a DMX connector on the next SL ParBlazer 100 UV or DMX512 device to be controlled Luminaire DMX512 RDM Input DMX512 RDM Output Figure 4 SL ParBlazer 100 UV DMX512 Input Output Connections Note For more information on DMX512 networking and systems refer to Additional Resources for DMX512 on page For SL ParBlazer 10
16. g publication is available for purchase from the United States Institute for Theatre Technology USITT Recommended Practice for DMX512 A Guide for Users and Installers 2nd edition ISBN 9780955703522 USITT Contact Information USITT 315 South Crouse Avenue Suite 200 Syracuse NY 13210 1844 Phone 1 800 938 7488 or 1 315 463 6463 www usitt org Showline Limited Two Year Warranty Showline offers a two year limited warranty of its luminaires against defects in materials or workmanship from the date of delivery A copy of the Showline two year limited warranty containing specific terms and conditions can be obtained by contacting your local Showline office Shewline TO TABLE CONTENTS Showline Offices IMPORTANT INFORMATION Warnings and Notices Additional Resources for DMX512 Showline Limited Two Year Warranty TABLE OF CONTENTS PREFACE About this Manual Included Items SL ParBlazer 100 UV OVERVIEW SL ParBlazer 100 UV Components INSTALLATION AND SET UP Connecting Power Connecting SL ParBlazer 100 UV to AC Power Connecting to the DMX512 Network Mounting Luminaire Truss Hanging Applications Floor Mounting OPERATION AND PROGRAMMING LCD Display and Menu System LCD Display and Menu System Operation SL ParBlazer 100 UV Menu Tree Master Slave Operational Mode Dimming Curve Selection DMX CONTROL SL ParBlazer 100 UV DMX Mapping 8 Bit Mode 16 Bit Mode RDM PARAMETER IDs SL ParBlazer 100 UV RDM Parameter IDs CL
17. ng f r Fehler oder Irrtuemer die in diesem Handbuch auftreten F r Bemerkungen und Verbesserungsvorschlaege oder Vorschlaege in Bezug auf Korrekturen und oder Aktualisierungen in diesem Handbuch moechten wir Sie bitten Kontakt mit der naechsten Showline Niederlassung aufzunehmen Le mat riel d crit dans ce manuel est pour information seulement et est sujet changements sans pr avis La compagnie Showline n assume aucune responsibilit sur toute erreur ou ommission inscrite dans ce manuel Pour tous commentaires ou suggestions concernant des corrections et ou les mises jour de ce manuel veuillez s il vous plait contacter le bureau de Showline le plus proche Note Information contained in this document may not be duplicated in full or in part by any person without prior written approval of Showline Its sole purpose is to provide the user with conceptual information on the equipment mentioned The use of this document for all other purposes is specifically prohibited Document Number SL ParBlazer 100 UV User s Manual Version as of 17th Sep 2015 0 SL ParBlazer 100 UV Installation amp User s Manual O 2015 Philips Group rights reserved SL ParBlazer 100 UV Installation amp User s Manual IMPORTANT INOFRMATION Warnings and Notices When using electrical equipment basic safety precautions should always be followed including the following a READAND FOLLOW ALL SAFETY INSTRUCTIONS AN b Do not mount
18. or International market only amp DMX Input cable 1000mm DMX Output cable 1000mm SL ParBlazer 100 UV Luminaire Cables S hewl n e About this Manual 3 Installation amp User s Manual SL ParBlazer 100 UV SL ParBlazer 100 UV OVERVIEW 1 SL ParBlazer 100 UV COMPONENTS Common Luminaire Components Rear of luminaire Yoke LCD Display Menu System Safety Cable Anchor Point Tilt Knob AC Input AC Output DMX512 DMX512 RDM Input RDM Output UV LEDs Figure 1 SL ParBlazer 100 UV Common Components LCD Display Menu System CHECK MARK OK Button EXIT Button CX 3 LEFT Arrow Button RIGHT Arrow Button ESC lt OK Figure 2 LCD Display amp Menu System Note For Menu operation and programming details refer to LCD Display and Menu System on page 9 4 SL ParBlazer 100 UV Overview S h Ow n e SL ParBlazer 100 UV Installation amp User s Manual INSTALLATION AND SET UP Power Requirements The SL ParBlazer 100 UV Luminaire operates on AC input voltages from 100 to 240 VAC WARNING The SL ParBlazer 100 UV luminaire does not have an ON OFF switch Always disconnect power input cable to completely remove power from the luminaire when not in use AC Power Operation When conne
19. pping of all DMX512 control values when the SL ParBlazer 100 UV LED Luminaire is in 8 bit DMX512 mode as set by the luminaire s menu system Table 3 SL ParBlazer 100 UV DMX Channel Mapping 8 Bit Mode DMX Parameter DMX Range Range Defaults Description 1 LED Intensity 0 255 0 100 0 LED Intensity 16 Bit Mode Table 4 provides DMX channel mapping of all DMX512 control values when the SL ParBlazer 100 UV LED Luminaire is in 16 bit DMX512 mode as set by the luminaire s menu system Table 4 SL ParBlazer 100 UV DMX Channel Mapping 16 Bit Mode DMX Parameter DMX Range Range Defaults Description 1 LED 0 255 0 100 0 Intensity Coarse 2 LED 0 255 0 100 0 Intensity Fine Shewline SL ParBlazer 100 UV Installation amp User s Manual 1 SLParBlazer 100 UV RDM Parameter IDs The following tables outline and describe all the RDM parameters IDs associated with SL ParBlazer 100 UV LED Luminaires Table 5 SL ParBlazer 100 UV RDM Product Parameters IDs Table 6 SL ParBlazer 100 UV RDM UID Table 7 SL ParBlazer 100 UV RDM Parameters IDs Table 8 SL ParBlazer 100 UV RDM Manufacturer IDs on page 17 Table 9 SL ParBlazer 100 UV RDM Manufacturer Specific PIDs on page 17 Table 5 SL ParBlazer 100 UV RDM Product Parameters IDs Model ID Model Description Product Category 0x1230 Philips Entertain Lighting Asia SL ParBlazer 100
20. the front lens Step 1 Turn Off luminaire and allow to cool completely Step2 Applyasmall amount of reagent grade isopropyl alcohol to lint free lens tissue Step3 Wipe all debris dirt fingerprints etc from lens Step 4 Using a second lint free lens tissue wipe off any alcohol residue Service and Maintenance For all other service and maintenance issues please contact your local Showline office or an Authorized Service Center WARNING Disassembly other than as described herein alterations unauthorized service etc will void the product warranty Contact your local Showline office or an Authorized Service Center for technical support and service Shewline CLEANING AND CARE SL ParBlazer 100 UV Installation amp User s Manual TECHNICAL SPECIFICATIONS 1 OPERATIONAL SPECIFICATIONS Source Beam Angle Light Output Field Angle Input Voltage Power Consumption Frequency Control Protocols Ambient Temperature Humidity Cooling Weight Housing Compliance IP Rating 40 5 High Power UV LED Array 20 Degrees 17 000 mW 38 degrees 100V to 240V 10 auto ranging 100 Watts max 50 60Hz DMX512 1990 DMX512A RDM On Board Menu 20 to 40 Degrees C 4 to 104 Degrees 5 95 Non condensing Passive convection 17 82 165 8 1 kg Luminaire only no mount AC input cable or accessories Die Cast aluminium with Powder Coating CB cETL C Tick FCC and