Home
Small-Ex-Transmitter (hol660) Manual
Contents
1. Zone 1 for gases and 2D Zone 21 for dusts The exact range of application can be found on the label of the device Special conditions for application safety and instructions for using the device The dimensions of the flameproof joints are in parts other than the relevant minimum or maximum values of IEC 60079 1 2007 For information on the dimensions of the flameproof joints contact the manufacturer The enclosure has to be integrated into the potential equalisation of the machine to be monitored this can be done either via the fastenings or via the connecting terminal The installer has to ensure that the equipotential bond is established by a qualified specialist in accordance with the relevant VDE regulations Lead in and connection cable The free cable end of the vibration monitor has to be connected either in an enclosure in one the types of protection stated in sec 1 of IEC60079 0 2007 or outside the explosive atmosphere The open end of the supply cable must be connected in accordance with current wiring regulations In applications in Zone 21 it must be ensured when installing the connection cable that electrostatic charging cannot lead to ignitable discharges The lead in and the connection cable are supplied with the device and are certified for the above mentioned application range for a minimum temperature resistance from 60T to 90 and comply with the requirements of the appli cable installation regulations Connection
2. cable Caution The device must never be transported suspended from the connecting cable It is not permitted to change the connection at the device or to change the cable Since the lead in does not have its own cable relief the connecting cable must be fixed by the user in the proximity of the lead in within a radius of approx 20cm The fixing must be executed in such a manner that the cable has no kinks and it is not damaged General points to be observed The operator installer has to find out the Ex regulation applicable for his her area of application and comply with the same The temperature specifications refer to values without pouring When pouring the installation conditions should be observed The supply voltage must be power limited components and executed according to the applicable Ex provisions Electronic Vibration monitoring Unit i holthausen ESW small Ex Transmitter elektronik GmbH 7 Grounding concept main control box with power supply optional vibration i bratio connection box control unit _ Shield signal ground Sie i F main control vibration control unit ground connection box ground l box ground v Vv Vv local ocal loca vibration control unit ground connection box ground main control box ground If an isolated installation is not specially requested usually through the attachment with screws each case is connected to the local machine ground In big facilitie
3. principle The vibration monitoring unit is generally mounted on the place where inadmissible vibration occurs or can be expected The unit is permanently monitoring the real condition or situation on the machine The noticed mechanical vibration detected by the sensor will be transformed to a corresponding electrical signal The sensor converts mechanical oscillations into an electrical alternating voltage The subsequent electronics converts the AC signal into a DC voltage which is equivalent to the measured oscillation speed A current in the range 0 to 20mA or 4 to 20mA or a voltage in the range 0 to 10V which is proportional to the measured value and corresponds to the measuring range is delivered over the analog output cable terminals 5 Connection technology The ESW small Ex Transmitter is available in two different basic versions Conventional technique This version is designed in such a way that two conductors are used for power supply and two conductors are used for the analog output Two conductor technique Although the term is defined there are various interpretations of the same In order to avoid misunderstanding a brief description of the use of the device is given below A Voltage is measured across the load resistance which is proportional to the current and thus to the measured value Load resistance Supply O Voltage signal B The current is measured using an ammeter e g SPS whic
4. well as a high noise level prevents often an acoustically or visual surveillance Thereby offers early detection taking care of the material and limitation of damage a considerable potential to the reduction in costs The ESW small Ex Transmitter monitors the vibration level for continuous process and outputs a current or voltage at the analog output which is proportional to the vibration acceleration The frequency range result from the characteristics of the measured object and the environmental reference In order to tune the device optimally to the vibration problem the measuring and frequency range can be adapted ex factory Either the vibration speed or the vibration acceleration can be selected as the quantity measured Depending on the measured object occurs the signal estimation according to the crest value or the effective value of the measurement Particular attention should be donated to the assembling place of the sensor decisively is the source of the signal that shall be measured and its mean vibration direction The assembling place of the sensor and alignment of the measurement axis of the sensor have to be selected so that the vibration possibly can be measured directly without interferences subdued crossings or defective couplings Attention Pay attention on requirement by entrance in Ex Zone Electronic Vibration monitoring Unit ESW small Ex Transmitter iil holthausen elektronik GmbH 4 Measurement
5. extremely low resistive as well as for long time stable Doing this take urgent notice to the valid VDE regulations max top hole A Surface a WANA screw locked M10x25 with LOCTITE protection The ESW small Ex Transmiter will be mounted via one threaded pin AM10 25 per DIN 913 on the machine to be monitored Important 1 Measuring axis has to be coinciding with vibration excitation axis see case drawing page 12 2 Take note of the label with instruction notes 3 The surface has to be plain clean and free of paint and rust 4 The tap hole has to be perpendicular to the surface and free of metal cuttings or other foreign material Further more the tap hole and the screw have to be free of paint rust grease or other isolating components 5 The grub screw has to be locked with liquid thread protection against unintended loosening 6 The unit has to be fixed tight on the surface 7 The advises to connection cable page 8 as well as Opening and closing of the vibration control unit page 11 are absolutely to note 10 Electronic Vibration monitoring Unit ESW small Ex Transmitter iil holthausen elektronik GmbH 9 Opening and closing of the vibration control unit The user must switch off the power supply before opening the measurement unit To open the unit the user needs a 0 9mm type of wrench inbus key and a forehead key with two bore
6. h is proportional to the Measured value Electronic Vibration monitoring Unit ESW small Ex Transmitter iil holthausen elektronik GmbH The voltage drop across the load resistance sketch A is directly proportional to the current flowing through the resistor Ohm s law U R x I and thus corresponds to the acceleration An ammeter sketch B can e g be the input 4 to 20mA of an SPS The load resistance and the internal resistance of the current input may not exceed a certain maximum value depending on the supply voltage The supply voltage must thus be selected in such a way that it is larger than the minimum supply voltage 10V and the voltage drop across the load and the internal resistance U gt U nin U The device operates linearly up to 22mA output current However a maximum current of 27mA can occur when the measuring range is crossed Formula for calculation of the maximum load and internal resistance U U min max R Examples Supply 12V DC RL 12V 10V 27MA 74 Q max Supply 24V DC RL 24V 10V 27mA 518 5 Q max Supply 30V DC RL 30V 10V 27mMA 740 7 Q max Electronic Vibration monitoring Unit ESW small Ex Transmitter iil holthausen elektronik GmbH 6 Special conditions for safe use in Ex zones The ESW small Ex is an operation resource for use in highly explosion prone areas in accordance with Directive 94 9 EC in the categories 2G
7. he unit and destroy the electronic Then the unit would loose their function Therefore the conditions from the mounting surrounding must be checked Then the cover material from the cable have to be proofed if it resists these requirements You can get an overview from the chemical resistance of the cover material from us 2 Packing and the transport Note e The sensor is sensitive to shock A downfall out lower height to an hard substratum can destroy the sensor e Avoid to kink or tie a knot in the cable e Keep the electronic in a dry place e Incase of a downfall or heckling or squeezing could the casing or the operation elements or the board get defects With adequate warning labels and through a qualified packaging and storage you can protect the sensor and electronics at carriage against influences from outside Electronic Vibration monitoring Unit ESW small Ex Transmitter iil holthausen elektronik GmbH 3 Application In many technical ranges there are vibrations frequently are they to neglect or even necessary but sometimes also undesirable or even dangerous Beside that can dangerously vibration conditions start slinking or occur total unexpected The reason for it often lies in mechanical defectives or improper handling of the machine The sequences are maybe diminution of the product quality or even loss of production and endangering of the security at least a raised wear and tear Increasing automation as
8. holthausen elektronik GmbH Ay User Manual Picture shows high grade steel case Electronic Vibration Monitoring Unit ESW small Ex Transmitter hol660 Ex transmitter date 25 07 2013 document hol660_small_ex_transmitter_hb_e technical modification possible holthausen elektronik GmbH is certified according to DIN EN ISO 9001 holthausen elektronik GmbH phone 49 0 21 53 40 08 info holthausen elektronik de Wevelinghoven 38 fax 49 0 21 53 89 99 4 www holthausen elektronik de 41334 Nettetal Electronic Vibration monitoring Unit i holthausen ESW small Ex Transmitter elektronik GmbH Table of Contents 1 Generally basical safety indications cceeee page 4 2 Packing and the transport ccceeeeceeeeseeeeeeeeeeeeeeeeees page 4 3 PUD ATION ec ceieioet a cteree tiene en page 5 4 Measurement principle cccccceeeeeeeeeeeeeeeeeeeeeeeeeeeees page 6 5 Connection technology cccccceeeeseseeecceeeeeeeeeeeeeeeees page 6 6 Special conditions for safe use in Ex zones page 8 T VOM CONCEPi sissies snina a page 9 8 Mounting of the vibration control unit eee page 10 9 Opening and closing of the vibration control unit page 11 10 IVAN ANC Cac seasons arta ae dewncacernaeip dee baacocerienins page 11 11 Display and operation elements ecceeeeeeeees page 11 12 Housing SIZ ccsecostaeitasste
9. itderetdeaeeeaeeenettealaoeeoneickonties page 12 13 Cable connection draft icc cecccscecccssesecccencaeissededeassncacneees page 13 14 Type registration sss cic secccenecesasacanececeuecesactunnecadeuscecetcnsens page 14 Declaration of COnmlOn ity see iccecscnccencenaneincscneseneseneeecent appendix Technical Data corti sec cateetlateette va evatee aaa leeds appendix Electronic Vibration monitoring Unit ESW small Ex Transmitter iil holthausen elektronik GmbH Important information These operation instructions are to be read through completely and carefully heeded before starting the device Failure to heed or adhere can result in claims on manufacturer s liability becoming null and void for damages ensuing there from Manual action of any manner on the device with the exception of proper procedures and those described in these operation instructions lead to forfeit of guarantee and exclusion from liability The device is solely intended for the usage as described below It is particularly not intended for the direct or indirect protection of persons holthausen elektronik GmbH assumes no liability whatsoever as regards suitability for some specific purpose If any question should remain open please never hesitate to contact us holthausen elektronik GmbH Wevelinghoven 38 41334 Nettetal Phone 49 0 21 53 40 08 Fax 49 0 21 53 899 94 Mail info holthausen elektronik de Electronic Vibration monitoring U
10. ng voltage on 11 holthausen elektronik GmbH Electronic Vibration monitoring Unit i ESW small Ex Transmitter 12 Housing size in mm with optional ground on earth terminal Case material Aluminium V2A or V4A picture 1 _ measuring axis 108 0 mm 76mm max 10mm top hole M10 15mm _ 4 ground on earth terminal 4mm optional SW22 30 mm The unit will be mounted via one threaded pin AM10 25 per DIN 913 Height differs for example shown above ESW small Ex 2241 Authorization N B BVS 08 ATEX E 088 X Material Aluminium high grade steel V2A or V4A Weight approx 1500g Protection IP 68 Cable insertion CAPRI Type ADE 1F 4F IP68 with Neopren airtight ring 12 Electronic Vibration monitoring Unit ESW small Ex Transmitter iil holthausen elektronik GmbH 13 Cable connection draft ESW small Ex Transmitter Version in conventional technology 24V supply volt e ground e white 24V supply voltage brown ground yellow analog output analog output o green analog output ground analog ground e shield see page 9 Grounding Concept Regulary the cable shield ends here in the housing case and is isolated to the case Version in two wire technology Current loop o white supply Reference o brown supply natantial Load or current measuring input shield see page 9 G
11. nit ESW small Ex Transmitter iil holthausen elektronik GmbH 1 Generally basical safety indications Don t use this device as the only invigilator if a malfunctioning of ESW Compact Ex could lead to damages on goods or Persons To obtain the desired result be sure that the device with its technical data fits to the bulk of the object you want to supervise The sensor is sensitive to shock A downfall out lower height to a hard substratum can destroy the sensor The assembling place and the execution of the assembling of the sensor determine decisively the quality of the sensor signal The assembling may only happen through qualified and instructed persons The electrical hook up is to be done by instructed persons A mistake by the connection can entail to faulty functions outfall or ruination of the sensor and electronics The ESW should not be used on machines with a very energetic high frequency solid borne Through resonance apparitions in the sensor the device can indicate a much too great or too small value Powerful noise sources for instance inverters in direct closeness of the sensor electronics or cabling can result in faulty behaving of the apparatus Potential differences and balance currents in the mass guidance can result in faulty behaving too The connection cable is resistant against many but not every type of chemical and mechanical stress Through a damaged cable chemicals could get inside t
12. nut with size of 4mm The case cover is ensured with a M2 screw These must be loosened before opening of the case cover with an inbus key After adjustment of the unit please control the position of the DIP switches Before closing the unit the O Ring must be examine You have to insert a new O Ring 43 x 2mm Si 970 FL original spare part if the old one is brittle deformed damaged or already a few month in use Please pay attention that the thread and the interior room is oil and dirt free Cleaning around and inside the unit should be done only with clean and dry cloth The closing and the sealing of the unit is done after app seven pitches of cover nut thread and ensured via the M2 screw Advises for dismantling Before dismantling the measurement unit the power supply must be switched off The connection cable has to be loosened from the supporting surface to avoid damaging of the cable The vibration control unit should be set free via a 22mm wrench key 10 Maintenance The ESW small Ex Transmitter is maintenance free Tools for case cover opening 0 9mm type of wrench Inbus key Adjustable forehead key for two bore nut size 4mm Factory H Sartorius Nachf GmbH amp Co phone 49 0 21 02 44 00 0 fax 49 0 21 02 44 00 24 11 Display and operation elements The display elements will be accessible after unscrewing the cover of the ESW small Ex Transmitter Display elements LED green on Operati
13. rounding Concept Regulary the cable shield ends here in the housing and is isolated to the case 13 Electronic Vibration monitoring Unit ESW small Ex Transmitter iil holthausen elektronik GmbH 14 Type registration The unit with the type registration ESW small Ex is certified by the ATEX guideline 94 9 EC for the use in gas air mixture under atmospheric conditions or burnable dust Labeling Registration elektronik GmbH WWw esw eU wevelinghoven 38 inolinousen Sate TYPE ESW small Ex at as lt Tamb lt C amp x 12G Ex d IIC T4 T6 Gb 12D Ex tb IlIC T80 T115 Db IP68 Ser Nr Monat Jahr Ser Nr ATEX Zul Nr BVS 08 ATEX E 088 X CE 0035 IECEx Zul Nr IECEx BVS 13 0006 X ESW is a registered trademark of holthausen elektronik GmbH Wevelinghoven 38 41334 Nettetal 14
14. s with considerable energy consumption and distances between the machines could such big potential difference be build up that substantial balancing current on the ground network will occur Dependent on intensity of such currents is arising of interference s or damaging of the unit the result Potential differences could also arise on machines with small distances not clear crossing of ground potential for example painted color or movable parts like suspension mounting Energetic high frequency interference energy could be added to the measurement signal wire by inductivity or trough capacity that could change the real existing measurement value In this way for example parallel going elements could act as coupling capacitor and winded up grounding cable could act like a cut off choke Memorize Ground is not equal everywhere gt Check the situation gt Plan the grounding concept gt Select the facility realization Electronic Vibration monitoring Unit i holthausen ESW small Ex Transmitter elektronik GmbH 8 Mounting of the vibration control unit Whole mounting connecting and adjustment work should be done from qualified personal only Protect the ESW small Ex Transmiter definitely against drop stroke and other mechanical shock The case of the unit must be connected over the attachment or the ground on earth Terminal with the potential compensation of the monitored machine The connection must be
Download Pdf Manuals
Related Search
Related Contents
2013-14 Cahie des Clauses Particulières Cargue el reloj completamente antes de usarlo \ __E RR68:Phflippe PETER 06 33 02 43 68 Contact compagnie HP® LASERJET P2035 • 2055 Moxa EDS-305 network switch Uso della Modalità Calcio - Migros universidade federal da bahia instituto de saúde coletiva BL600 smartBASIC Module CIMPLICITY HMI Routing Control Objects Operation Manual Copyright © All rights reserved.