1. Ouick Start Installation Checklist O 24 VAC power supplied to the ECO3 Fuses fitted and in place Force Save test is successful Compressor runs correctly with ECO3 wired in Customer is briefed on ECO3 indicator lights and knows how to perform a Manual Bypass Customer is given the ECO3 User Manual and contact details for technical support Customer is happy with the installation SMARTCOOL PDF Handouts e Quick installation guide e Full installation operation and trouble shooting manual e On site user manual Fa gt SS bri TAA u 5 Gum uu Gw fee i Post Installation Performance verification SMARTCODL The Smartcool Display e Validation of energy saving measures can be hard e Smartcool products have a simple display to show status and performance Status indicators Hours Run Hours Saved Hours Bypassed Saved hours Run hours Save hours Automatic override hours Saved kWh Saved Saved hours x kW motor size s y i e erm AS Us agg Saving Calculator Visit the ECO3 web site for an online savings calculator Ss MART n a wt Me Home The ECO3 Distribution About Smartcool Contact Us Savings Calculator h tt D www e S m a rtco O eco 3 CO m The ECO3 logs demand from the compressor right on its large display SMART ECO3 Savings Calculator screen You can scroll through the data using the Enter button For a detailed explanation
2. Todays Agenda e Overview about Smartcool How our products work Installation of an ECO3 e Post installation validation View the actual installation e Lunch e Hands on ECO3 demo unit e Q amp A SMARTCODL About Smartcool SMARTCODL Smartcool Systems Inc e Founded over 20 years ago by an Australian refrigeration engineer e Purchased by a team of Canadian investors in 2006 Developed as a an energy efficiency solution for commercial and industrial HVAC R systems e Smartcool s energy efficiency solutions have been adopted by some of the world s most prominent companies across a range of industries e Over 30 000 installations worldwide SMARTCOOL What Is Smartcool e Smartcool is the developer manufacturer distributor of a unique hardware software control solution e Reduces the electricity usage kWh of air conditioning refrigeration and heat pump compressors by improving the performance of the compressors while maintaining temperature and humidity control e Smartcool is a modular retrofit technology can be applied in air conditioning refrigeration and heat pumps systems e Risk free solutions compatible with all existing equipment and controls e Average payback period for customers is 18 to 36 months gt gt ex TM f ca f a e Lo un Our Products ECO3 SMART SMARTCOOL The ECO3 Suitable for single and twin compressor s
3. far the most amount of energy is the electric motor of the compressor Electrical Load Often this one element can consume up to 7090 of the total energy used by the refrigeration plant e Smartcool s energy saving controls focuses on this one item E The Compressor Everything Else SMARTCOUOOL Run Time As a control solution the aim of Smartcool is to reduce the amount of time the compressor needs to run for over and above that ofthe existing control strategy e When a compressor is not running it doesn t use any energy e You could just switch the compressor off and save energy but the downside would be an impact on the end temperatures reguired e Smartcool has a method of reducing the run time of a compressor AND still maintain the reguired temperatures We don t use magic but rely on science and the physical characteristics of refrigerant These principals are known by every cooling engineer SMARTCOOL The Science n simple terms the compressor is just a pump pumping an amount of refrigerant gas around the cooling system e Like a car engine the compressor has a fixed volumetric compression chamber However at different refrigerant temperatures and pressures the capacity of the compressor changes SMARTCOOL Temperature amp Pressure v Capacity e At higher refrigerant temperatures and pressures when the gas is more dense the refrigerant molec
4. already wire into the ECO3 Remove the small green terminal connector marked 24 channel terminal connector An ECO3 Dual will have two VAC and wire in the power supply inputs channels to wire in Remove the wire casing to access the connector blocks Remove the green terminal connector from the base of the Check that all the wiring connections are secure ECO3 and wire into the IN NO NC and CMN points Make a note of which coloured wire connects to each point SMARTCOOL Installation Quick Start Step 5 Step 6 Confirm that the wiring is running smoothly out of the Mount the ECO3 on the backplate by sliding it up until it wiring casing clicks onto the metal bracket Close the base of the ECO3 Screw the wiring casing base into the main body of the ECOS SMARTCODL Installation Quick Start Step 7 Step 8 Run the wiring from the ECO3 to where you will wire into Install the correctly rated fuse and associated fuse carrier the control circuit for circuit protection Use zap straps cable ties or other suitable means like in the image below on the left to make sure the wiring is neat and tidy ASIN the example in the lower right image you may need to drill inte a control panel using the appropriate rubber seals to maintain the integrity of the panel and to protect the cabling SMARTCOOL Installation Ouick Start Step 9 Fit the appropriate terminals onto the wiring from the ECO3 ensurin
5. art Recommended Pre Installation Steps ECO3 Before setting out to complete any ECO3 installation you should be familiar with the detailed content of the ECO3 Q Ul ck In sta lla tion G ul d e Installation Manual In addition Smartcool recommends you take the following steps prior to installation 1 Know what power supply is available at the installation site understand the control circuit of the system and determine where you will be mounting the ECO3 Collect the necessary peripheral items Remove the wiring cover on the ECO3 Connect the wiring to the channel s inputs and to the 24 VAC input Close the wiring cover and fasten with the supplied screws Pre wiring the ECO3 will make the installation itself much easier Alternatively you can do this on site by following the steps in this guide SMARTCOOL Installation Quick Start Step 1 Decide where you will mount the ECO3 and how much wire is needed to reach from the ECO3 to where you will wire into the control circuit The ECO3 needs to be mounted on a flat surface If installed outdoors it needs additional protection correctly rated to the environment SMARTCOOL Step 2 Mount the ECO3 backplate Ifyou need a transformer for the power supply mount this as well Make sure that you are mounting the backplate straight and using the appropriate fixtures for the surface Installation Quick Start Step 3 Step 4 If you have not done so
6. g that you are referencing the correct wires Refer to the ECO3 Installation Manual for further detail wiring diagrams and any aditional wiring that may be necessary for your specific installation SMARTCOOL Step 10 You are now ready to connect the power supply to the ECO3 Ensure that the system is free from voltage before you wire in Ideally you will wait until the compressor cycles off then turn off the master power supply rather than cutting the compressor off mid cycle On the power supply input to the ECO3 wire in a circuit breaker or appropriate fuse Installation Quick Start Step 11 Ensure all your wiring is correct before turning the master power supply to the system back on Start the ECO3 in Force Save also known as false save mode to check that you have installed the unit correctly To do this press and hold down the ENTER button as you turn the master power supply back on The display will read FS The compressor should stop for the duration of the Force Save If it does not refer to the ECO3 Installation Manual for troubleshooting steps SMARTCOOL Step 12 Provided the Force Save test is successful you can allow it to exit the Save cycle on its own The display will change to ON The installation is now complete Make sure you leave the ECO3 User Manual and Installation Sticker with the ECO3 unit for easy reference Also leave your contact details on site Installation
7. of what the data means watch our short Want to know how much your ECO3 is saving you You ll need the following information video demonstration 1 On your ECO3 use the Enter button to cycle through the Run Save Bypass and Override hours Write down the information from the screen Using only this information you will be able to see the percentage of compressor run time the ECO3 is saving you See Step 2 for additional results Note If you have an ECO3 Dual you need to cycle through the hours for both Channel 1 and Channel 2 2 If you want to calculate your estimated energy savings as kWh as well as a percentage of hours write down the RLA amperage voltage and number of phases from your compressor face plate or label Unit ID Choose your Model SMART OO Help using this calculator is available by emailing info smartcooLnet SMARTCOC PDF Handouts ECO3 Proof of savings SMARTCOOL i O XL O C
8. ules are all more closely packed the compressor is able to pump more refrigerant we say it has a greater mass flow rate At lower refrigerant temperatures when the gas is less dense the compressor is able to pump less refrigerant we say it has a lower mass flow rate SMARTCOOL What Smartcool Does The Smartcool control solution aims to dynamically adjust the cut in and cut out point of the compressor By doing this it can effect the suction pressure that the compressor is working at increasing its COP 2 e lf we can increase the amount of cooling being provided when the compressor runs to achieve the same amount of cooling as the existing control we can run the compressor for less time and therefore save energy SMARTCOOL Installation The Smartcool is installed in series with the existing control solution e It monitors the load of the plant and when the existing control is demanding for cooling it can allow the compressor to run of it can turn it off Typical run time savings are between 15 and 25 equating to a reduction in kWh consumption of similar levels There will be no negative impact on the end temperatures SMARTCOOL PDF Handouts e Elevator Pitch Presentation ECO3 FAQ SMARTCOOL i Installation i a Sa NL rd rr i NI BER 1 o a e Eb n SMARTCODL Installation Quick St
9. ystems e Refrigeration Air Conditioning or Heat Pumps e P64 Rated for outdoor installation e Minimal technical knowledge needed for installation SMART The ESM e Modular systems provides total flexibility e Refrigeration Air Conditioning Single stage of multi stage compressors e Turbo core Centrifugal Screw Reciprocating Scroll e Remote Coms package available Dynamic demand response available cool SE Y ni a CAST Key Features Reduces compressor run times through more efficient control Average kWh savings ECO3 15 to 25 ESM 10 to 20 e Interfaces with existing controls does not replace them e Provable savings e Zero risk to current equipment or effect on manufacturer warranty e Maintains temperature performance MAL TM Lan y Y Con fe AA gt Target Markets Food Retail e Fast Food Outlets Coffee Shops e Banks e High Street Non Food Retail e Data Centres e Food Manufacturing e Manufacturing Process Cooling i 5 thas er ho muf Qa gi ny Cold Chilled Storage Hotels Hospitals Large Office Buildings Gyms PDF Handouts e Smartcool Corporate Brochure e Product Brochure for ECO3 and ESM e Some case studies SMARTCOOL i o How Does It Work Non Technical Explanation SMARTCODL The Compressor e In any refrigeration system the piece of equipment that uses by