Home

iShak UNO VT - Neuation.com

image

Contents

1. the data logger file for future reference Click on the CLEAR button to clear the sample note and details 14 12 REMOTE OPERATION 12 5 DATA LOGGER The remote operation comes with data logger features All operations performed through the GUI will be saved in a excel sheet With the help of data logger user can view and take a print out of previously performed operation User can access the data logger file from the desktop The data logger file will generate automatically on desktop of user s computer once operation is performed The following type of operation details will saved in an excel sheet fund pmb palo pu wN he O 14 A B E D E Ea 4 4 4 EEE EEE RAEE AEREA Date Tuesday December 24 2013 Time 2 33 22 PM ID SA1312AA0001 Version G1 1 D1 1 Operation No 2 Sample Note SET SPEED 200 RPM SET TIME 10 MIN STOP SPEED 200 RPM STOP TIME 10 MIN 57 SEC RUN TIME 0 Hour And 0 Min And 3 Sec NOTE The GUI software will not operate if data logger file is open Be sure to close the log sheet before remote operation 15 13 SAFETY PRECAUTION amp MAINTENANCE 10 11 12 13 Do not lift the shaker by holding the microplate or shaking platform Unplug the power adaptor before cleaning Always operate the unit on a leveled amp stable surface to avoid any kind of accident Spill if it occurs it should be removed promptl
2. the guidelines specified in this instruction manual This warranty does not cover damage caused by accident neglect misuse improper service natural forces or other causes not arising from defects in original material or workmanship This warranty does not cover any incidental or consequential damages commercial loss or any other damages from the use of this product The warranty is invalidated by any non factory modification which will immediately terminate all liabilities on us for the products or damages caused by its use The buyer and its customer shall be responsible for the product or use of products as well as any supervision required for safety If requested the products must be returned to the distributor in well packed and insured manner and all shipping charges must be paid Some states do not allow limitation on the length of implied warranties or the exclusion or limitation of incidental or consequential damages This warranty gives you specific legal rights This warranty is given expressly in lieu of all other warranties expressed or implied 17 14 WARRANTY STATEMENT The purchaser agrees that there is no warranty of merchantability or of fitness for any intended purpose and that there are no other remedies or warranties expressed or implied which extend beyond the description on the face of the agreement This warranty is only applicabletothe original purchaser The software is made available with the kit I
3. Anti spill operation even at higher speeds e Rubber suction cups for firm grip amp stable operation e Adjustable time from 1 to 180 minutes amp continuous mode e USB port for remote terminal control capability e Remote operation with data logger 4 ACCESSORIES 1 Replaceable clamps and O Rings 2 USB Cable 3 Alternate clamps amp adjustable clamp 4 Power adaptor 5 Product user manual amp warranty card 6 Foam Attachment 5 TECHNICAL SPECIFICATION Orbital Motion Variable Speed Max Speed Maximum Volume LED Indicator Recommended plate size LxW 127 76mmx85 48mm weg Dimensions L x W x H Rated input of adaptor Permissible ambient Temp Permissible relative moisture Power Requirement 6 INSTALLATION Gently take the shaker out from packaging box and place it on the flat stable clean and non slippery surface Keep 2 inches clearance from all 4 side of the shaker so that it can be operated easily and safely Do not lift the shaker by the shaking platform Check that the rubber suction cup attached to the table well Plug in the power adaptor pin before connecting to power source The instruction manual and accessories should be kept with the device and please keep all the packaging in safe storage for atleast 2 years for warranty purpose The standard clamps are pre installed and a set of alternate clamps are supplied with the unit In case to remove or replace the clamps gently pull the clamps up af
4. NCUDCIO 7 1Shak Uno VT Personal Microplate Shaker PRODUCT USER MANUAL CONTENTS Ms MM POOUCTIO HE E E ere 1 2 intended USE rra 1 o 1 o A Eee eeu 2 5 Technical Specmica OMe taseincosacapincesstacastaiecaneteenacmstuaeiece 2 BAS FAR EO Netos nadas 3 7 Installing plate using O RIN8 ocoocccncccncncncncncncncnonanonanos 6 MA eo re ede 7 SE DES Ol Clarisa 8 TOODO IUO rms aniss 9 11 Tips for Efficient OperatiON cooccccncccnncncnonnnannnnonnnnss 10 12 Remote OperatiON ooococonccoconccnconccnnonccanoncnanoncnnonos 11 FS Sae ty PRECAUTIONS enn S E 16 14 Warranty Statement oococcococcncnccnccncnncnccnconcnccnnonono 17 IS Prod ct DISPOS A eses aE EER 19 1 INTRODUCTION The compact personal microplate shaker is designed for accurate amp even mixing of samples in a microplate It is optimized to accept all standard plates and its 2 0 mm orbital motion allows thorough mixing across each well The speed can be set from 200 to 1500 rpm 2 INTENDED USE Personal Microplate Shaker is used for mixing liquids in a microtube It can be used in areas of biochemistry medicine biotechnology and microbiology laboratories research 3 FETAURES e Exceptionally small footprint e Uniformly shakes the microplate e Accepts all standard microplates e Replaceable clamps to hold different microplates e Simple tool free clamp replacement e Adjustable speed from 200 to 1500 RPM e
5. OFF switch will function To stop operation turns OFF the power switch from back side NOTE Operation starts with slow speed amp steadily rise to set level 11 TIPS FOR EFFICIENT OPERATION Orbital shaking is undoubtedly a simple way for mixing of assay components but simply putting the samples on a microplate doesn t guarantee complete blending is reached after the mixing process A wide variety of well microplates are commercially available The basic requirement to ensure a fast and efficient mixing result is the generation of vortex which allows to produce a flow of the total sample volume The adjustment of the optimal mixing speed for microplates is dependent on the size of the well and the filling volume The below table is a short summary for recommended mixing speeds for different microplates Mixing speeds rpm for different microplates depending on filling volume well Filling Volume 96 Standard 96 Deep well 384 Standard in well well 1400 RPM 300 RPM 1500 RPM 1200 RPM 600 RPM 1400 RPM Hence Ideally larger volume should be mixed with a higher orbit and low speed Smaller volume requires a lower orbit but a much higher speed Note Overfilling of wells can lead to spillage 10 12 REMOTE OPERATION For remote operationthe shaker needsto be connected to a computer 12 1 SYSTEM REQUIREMENT For remote operation the following are the minimum system requirement 1 Windows 7 with i3 Process
6. PROGRAM SELECTION Depending on the number of wells and total volume every microplate requires specific speed and time value for proper and anti spill mixing The GUI offers pre defined shaking speed and time for the 3 common microplate use in this shaker Select the pre set program of specific microplate and then click on the start button to start operation 12 4 3 OPERATING THE SHAKER SPEED 9200 MN Mox 1500 Rpm Adin 200 Rom START To operate the shaker set the speed and time then click on the START button to start operation To stop operation click on the STOP button 13 12 REMOTE OPERATION 12 4 4 SETTING PROGRAM AND ITS SELECTION SPEED RPM TIME MIN i T 7 A LA SWE User can save upto 4 user defined programs To set program click on the speed and time up down scroll button of specific program and set the desired value After setting desired speed and time value click on the SAVE button to save the programs To start the operation as per set program click on the specific program button and then click on the start button to start the operation 12 4 5 PROGRAM SAMPLE NOTE AND DETAILS Sample Note Details User can write the details of sample used 96 Standard Well for shaking for their reference User can Microplate with X sample gs also write any other specific information inside which is worth mentioning according to user The data entered here will save in
7. f microplate is not attached firmly or it moves on the shaking platform during operation then to attach microplate firmly O Rings are needed to attach first Below figure shows that microplate is not attached firmly Now take out the O Rings from the packaging box and attach it on the clamps as shown in below figure Attach as shown above Attach on 2 vertical side as shown in figure 8 INSTALLING FOAM Shaker Foam is use to shake samples using microtubes It supports all standard microtubes and have the capacity of 20 microtubes Tips for efficient operation The basic requirement to ensure a fast and efficient mixing result is the generation of vortex which allows to produce a flow of the total sample volume Based on the density of the samples speed of the shaker and volume should be maintain Hence Ideally larger volume should be mixed with a higher orbit and low speed Smaller volume requires a lower orbit but a much higher speed Please see the below image to learn how to attach the shaker foam in the shaker platform TT O Ring Foam Placing foam on shaking platform The above image shows the image of Foam Place this Foam on the shaking platform and use O Ring to attach the foam Tight the Foam by pushing the O Ring on the back side of the champs as shown in above figure Once the Foam is attached place the microtubes for shaking Note Filling microtubes more than 60 and shaking it at max speed can
8. lead to spill 9 TYPES OF CLAMPS Three types of clamps are provided with personal microplate shaker Type A clamp Universal Clamp Type B clamp amp Adjustable clamp as shown in the below figure Type A clamps Adjustable clamp are pre installed and Type B clamps are with accessories Type A Type B Adjustable Fix Universal Clamp Fix Clamp Clamp USING DIFFERENT TYPES OF CLAMPS 1 Type A Clamps are universal clamps and are use For most standard plates 2 Type B Clamps are use for larger microplates which contains outside ribs 3 Adjustable Clamps are use to place microplate easily and lock it after placing it 10 OPERATION To start the operation connect the power adaptor to adaptor port in the backsideofthe shaker USB Port Power Switch Adaptor Port Time Mins Speed RPM 25 3045 50 0 800 1000 Back Side Front Side Before starting the shaker set speed and time from the control panel given in front side of the shaker Rotate speed knob to set speed and rotate time knob to set time After setting the required speed and time start operation by turning ON the power switch from the back side The power LED in front will glow as an indication that shaker is started NOTE One can change time amp speed during operation For remote operation connect the USB cable to the back side of shaker Once USB cable is connected controls of shaker will be disabled amp only the ON
9. or or more and Windows XP Service Pack 3 2 Microsoft NET framework 4 and Microsoft Office Excel 2007 or 2010 12 2 INSTALLING SOFTWARE Software CD is provided with the shaker kit Install the software by running the setup file The software Installation guide is provided in the software CD After installation software icon will appear on the desktop 12 3 CONNECTING USB CABLE Connect one side of USB cable to the back side of shaker and another side to computer USB port 11 12 REMOTE OPERATION 12 4 UNDERSTANDING amp OPERATING GUI After installing the GUI software open GUI software by double clicking the software icon The following GUI window will open on the computer screen EA FEE SPEED APRO TAE MENI Gate Tuesday Decembar 10 4013 Tome 12 12 43 PMI Once you connect the USB cable the COM PORT for the shaker is detected automatically Now click on the CONNECT button to connect shaker and computer for remote operation After connection the TEXT BOX will show COM iShak Connected Note If any other device is connected after connecting Shaker then the COM PORT of software gets update So Select the shaker COM PORT from the COM PORT drop down box and click connect to reconnect the shaker 12 12 REMOTE OPERATION The following change of image will appearin GUlscreen DISCONNECTED CONNECTED 12 4 2 PRE SET
10. t is designed to work on Windows XP SP3 Windows 7 The software should be used as explained in the user manual The warranty does not cover the software failures due to issues in user system computer or laptop Products received without proper authorization will not be entertained All items returned for service should be sent postage prepaid in the original packaging or other suitable carton padded to avoid damage We will not be responsible for damage incurred by improper packaging All items returned for service should be set postage prepaid in the original packaging or other suitable carton added to avoid damage This warranty is valid only ifthe warranty is registered with the supplier within 30 days from the date of purchase 18 15 PRODUCT DISPOSAL In case the product is to be disposed of the relevant legal regulations areto be observed Information on the disposal of electrical and electronic devices in the European Community The disposal of electrical devices is regulated within the European Community by national regulations based on EU Directive 2012 19 EU on waste electrical and electronic equipment WEEE According to these regulations any devices supplied after 13 06 05 in the business to business sphere to which this product is assigned may no longer be disposed off in municipal or domestic waste They are marked with the following symbol to indicate this As disposal regulations within the EU may
11. ter unlocking to remove and push down in the Fix Universal Clamps Adjustable T 3 grooves to fix it again Fix Universal Clamps Adjustable Clamp Removing Clamps Installing Clamps Note The front side of the shaker contain speed amp time knobs and back side contains power switch adaptor amp USB ports A special adjustable clamp is provided on the backside 6 INSTALLATION Now to place the microplate on the shaking platform between 4 clamps gently open the adjustable clamp to 90 as shown in the below figure Microplate cannot be placed attached properly to shaker if clamps are not fitted to it Recommended microplate size LxW is 127 76mm x 85 48mm amp height from 14 2mmto 22mm Rotate 90 Opening Adjustable Clamp After opening the adjustable clamp to 90 place the microplate as shown in the next figure Gently pull the microplate inside and lock the clamp by turning 90 to firmly tight the microplate on shaking platform Note The front side of the shaker contain speed amp time knobs and back side contains power switch adaptor amp USB ports A special adjustable clamp is provided on the back side 6 INSTALLATION Rotate 90 4 Locking Clamp to firmly tight microplate Note We recommend to place the adjustable clamp on the back side of shaker 7 INSTALLING PLATE USING O RING After placing or attaching the microplate between 4 clamps i
12. vary from country to country please contact your supplier if necessary 19 om Se L IN ge NR C ge gt s DO e e 0 or 0 or N DO Neuation Technologies Pvt Ltd s Plot no 16 Part of GIDC Electronics Park SEZ val Kolavada Road Sector 26 Gandhinagar Gujarat India Ph 91 2764 248241 Fax 91 2764 248243 www neuation com a info neuation com s ge Se s o UN UN f f O S A Se ES AS ZO GN GN
13. y Do not immerse the unit in liquid for cleaning The whole unit should be cleaned regularly with a moist cloth Ensure that while cleaning the unit is not plugged in Always keep the Shaker clean Whole unit should be wipe down periodically with a soft cloth Excessive amount of liquid should be avoided Liquid should not come in contact with the motor After cleaning ensure that all parts are dried Shaker should be used for the specified application only It must not be operated in a hazardous or flammable environment and must not be used to mix explosive or highly reactive material Do not use shaker in hazardous atmosphere or with hazardous material for which the unit is not designed Do not operate the unit if it shows signs of electrical or mechanical damage If any such damage is found contact supplier Always use the supplied and recommended accessories for best result and product safety The equipment will restart both in case of mains interruption and inthe case of any fault or mechanicalinterruption So the care should be taken based on the sample used for mixing 16 14 WARRANTY STATEMENT This products is warranted to be free from defects in material and workmanship for a period of two 2 years from date of purchase Your product will be duly repaired upon prompt notification in compliance with the following conditions This warranty is valid only if the product is used for its intended purpose and within