Home

XCCN Data Sheet/Manual PDF

image

Contents

1. Fax 86 21 6113 3683
2. Gently apply pressure on the screwdriver in an upward direction until the expansion port cover disengages from the unit as shown in Figure 1 Verify that the option card knobs are in the unlocked position as shown in Figure 2 Carefully insert the option card into the expansion port opening while aligning the card edge connector on the option card with the main board s header as shown in Figure 3 Once aligned gently press on the front of the card until it is flush with the front of the case Turn the option card knobs to the locked position as shown in Figure 4 Figure 1 Figure 3 XCCN RUNERR Caution The expansion and main circuit boards contain static sensitive components Before handling the cards discharge static charges from your body by touching a grounded bare metal object Ideally handle the cards at a static controlled clean workstation Also handle the cards by the edges only Dirt oil or other contaminants that may contact the cards can adversely affect circuit operation Warning Risk of Danger Be sure to remove all power before removing the expansion port cover Figure 2 XCCN RUN ERR Figure 4 POWER SUPPLY REQUIREMENTS NEW AND EXISTING INSTALLATIONS The XCCN option card draws all
3. or replacement of a defective product at The Company s option The Company disclaims all liability for any affirmation promise or representation with respect to the products The customer agrees to hold Red Lion Controls harmless from defend and indemnify RLC against damages claims and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created with respect to The Company s products except those expressly contained herein The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations Red Lion Controls Red Lion Controls India Europe 54 Vishvas Tenement Printerweg 10 NL 3821 AD Amersfoort Tel 31 0 334 723 225 Fax 31 0 334 893 793 GST Road New Ranip Ahmedabad 382480 Gujarat India Tel 91 987 954 0503 Fax 91 79 275 31 350 Red Lion Controls China Unit 101 XinAn Plaza Building 13 No 99 Tianzhou Road ShangHai P R China 200223 Tel 86 21 6113 3688
4. nboard termination resistor is selectable via a jumper setting The termination resistor is rated for 124Q at 1W If a different termination resistance is desired choose the jumper setting for no termination resistor and connect your own termination resistor between positions 2 and 4 of the five position connector GND Position of the pluggable connector provides a CAN ground connection This terminal is isolated from the Modular Controller Master and Data Station Plus CAN Position 2 of the pluggable connector provides the CAN bus line active low This terminal is isolated from the Modular Controller Master and Data Station Plus SHLD OPTIONAL CAN SHIELD Position 3 of the pluggable connector is provided for optional shield connections This position is available only to tie shield wires together or to earth ground There is no internal connection to earth ground The SHLD position is not connected to any circuitry internal to the XCCN option card or Modular Controller Master and Data Station Plus CAN Position 4 of the pluggable connector provides the CAN bus line active high This terminal is isolated from the Modular Controller Master and Data Station Plus V OPTIONAL 24 VDC Position 5 of the pluggable connector is provided for optional 24 VDC connections This position is available only to tie 24 VDC wires together The XCCN card neither provides 24 VDC power nor uses 24 VDC power through this connection The V po
5. of its power from the main board of the Modular Controller Master or Data Station Plus The specifications of the Modular Controller Master or Data Station Plus account for the power needs of an option card COMMUNICATING WITH THE XCCN OPTION CARD CONFIGURING A XCCN OPTION CARD The XCCN is configured using Crimson software Crimson is available as a free download from www redlion net or it can be ordered on CD Updates to Crimson for new features and drivers are posted on the website as they become available By configuring the XCCN using the latest version of Crimson you are assured that your unit has the most up to date feature set Crimson software can configure the XCCN through the RS232 PGM port USB port Ethernet port or CompactFlash socket on your Modular Controller Master or Data Station Plus Additional information can be found in your Modular Controller Master or Data Station Plus hardware bulletin and the Crimson user manual CANopen PORT PROTOCOLS The XCCN option card has one CANopen port This port may be configured for various CANopen protocols Check www redlion net for currently supported protocols XCCN PORT PIN OUTS Must use only NEC Class 2 or Limited Power Source LPS rated power supply ees oa hs TERMINATION RESISTOR GND DEFAULT SLD OFF CAN MLK K V K NL 2 TERMINATION RESISTOR An o
6. pict ce a 1 POWER REQUIREMENTS 24 V 50 mA max Power is supplied to the option card from the main board of the Modular Controller Master or Data Station Plus COMMUNICATIONS CANopen Port The CANopen port has format and baud rates that are software programmable up to 1M baud and are digitally isolated This port may be configured for various CANopen protocols Check www redlion net for currently supported protocols Isolation from XCCN Communication ports to the Modular Controller Master or Data Station Plus 1000 VDC for 1 minute CERTIFICATIONS AND COMPLIANCES Refer to main unit manual or Agency Approvals section of Red Lion s website for agency certifications ELECTROMAGNETIC COMPATIBILITY Emissions and Immunity to EN 61326 Electrical Equipment for Measurement Control and Laboratory use Reference Modular Controller Master or Data Station Plus unit for EMC specifications 4 ENVIRONMENTAL CONDITIONS Refer to the specifications of the Modular Controller Master or Data Station Plus you are installing this card in CONSTRUCTION For indoor use only Installation Category II Pollution Degree 2 INSTALLATION REQUIREMENTS See Installing the XCCN Option card for more details 7 WEIGHT 2 3 oz 65 2 g N w nn D BLOCK DIAGRAM ISOLATING DC DC INSTALLING THE XCCN OPTION CARD 1 Remove power from the unit 2 Insert a flat bladed screwdriver into the slot at the top of the expansion port cover
7. red it Tel 1 717 767 6511 Fax 1 717 764 0839 www redlion net Bulletin No XCCN A Drawing No LP0667 Released 08 11 MODEL XCCN CANopen OPTION CARD FOR DATA STATION PLUS AND GENERAL DESCRIPTION Both the Modular Controller Master enhanced models and Data Station Plus contain a proprietary expansion port which provides a high speed parallel architecture that extends the functionality and flexibility of the platform This approach allows these products to evolve concurrently with the latest advances in communications and standards without sacrificing performance This high bandwidth channel has significantly greater throughput when compared to the traditional external serial gateway approach The XCCN option card adds a CANopen communication port to the series This isolated card protects user equipment from potentially harmful ground loops while providing the ability to communicate to any high speed CANopen device The XCCN option card has a termination resistor built in which is selectable via a jumper setting Additionally the XCCN connector is pluggable for easy removal of the Modular Controller Master or Data Station Plus from the CANopen bus without disturbing communications with other devices on the bus The XCCN communication card is easily installed by removing the blank expansion port cover of your Modular Controller or Data Station Plus and plugging the XCCN card into the expansion port Configuration is simple
8. sition is not connected to any circuitry internal to the XCCN option card or Modular Controller Master and Data Station Plus LED The LED will illuminate green when the XCCN option card establishes communication with other CANopen devices RUN The LED will illuminate red if no communications have been established with other CANopen devices ERROR CRIMSON SOFTWARE Crimson 2 0 software is available as a free download from www redlion net or it can be purchased on a CD see Ordering Information for part number The latest version of the software is always available from the web site and updating your copy is free TROUBLESHOOTING YOUR XCCN OPTION CARD If for any reason you have trouble operating connecting or simply have questions concerning your new XCCN option card contact Red Lion s technical support For contact information refer to the back page of this bulletin for phone and fax numbers EMAIL techsupport redlion net Web Site http www redlion net Red Lion Controls Headquarters 20 Willow Springs Circle York PA 17406 Tel 1 717 767 6511 Fax 1 717 764 0839 LIMITED WARRANTY The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from the date of shipment provided the products have been stored handled installed and used under proper conditions The Company s liability under this limited warranty shall extend only to the repair
9. using Red Lion s free Crimson 2 0 software SAFETY SUMMARY All safety related regulations local codes and instructions that appear in the literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Do not use the controller to directly command motors valves or other actuators not equipped with safeguards To do so can be potentially harmful to persons or equipment in the event of a fault to the controller CAUTION Risk of Danger Read complete instructions prior to installation and operation of the unit ORDERING INFORMATION MODEL No NO DESCRIPTION PART PARTNUMBER CANopen option card for Modular Controller or ZGON Data Station Plus XCCN0000 SFCRM2 SFCRM200 Crimson 2 0 with G3 Data Station Manual 1 SFCRM2 Crimson 2 0 with Modular Controller Manual SFCRM2MC Use these part numbers to purchase Crimson 2 0 on CD with a printed manual USB cable and RS 232 cable Otherwise download free of charge from www redlion net MODULAR CONTROLLER CONFIGURED USING CRIMSON SOFTWARE VERSION 2 0 OR LATER DIGITALLY ISOLATED CANopen PORT CAPABLE OF COMMUNICATING WITH ANY CANopen DEVICE EASY INSTALLATION CANopen CONTENTS OF PACKAGE XCCN option card This hardware bulletin

Download Pdf Manuals

image

Related Search

Related Contents

MELOOK-DGなら  Filament Design CLI-ACG192675 Installation Guide  Yamaha RM602 Operating Instructions  三重県公共工事進行管理システム概要  Waschmaschinen - Alle-Bedienungsanleitungen.de  Micrelec - Byblos  FUCILE - Bignami  Mémoire - Rero Doc  Manual little ACTUAL -  85048 - Hisinsa  