Home

User Manual

image

Contents

1. Sh Intense 9HEX10 LED Slim Par 9 x 10W 6 in 1 colour LEDs RGBWAUV User Manual ed no fan Order code LEDJ254A Safety advice WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP e Before your initial start up please make sure that there is no damage caused during transportation e Should there be any damage consult your dealer and do not use the equipment e To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual e Please note that damages caused by user modifications to this equipment are not subject to warranty CAUTION CAUTION TAKE CARE USING KEEP THIS EQUIPMENT THIS EQUIPMENT AWAY FROM RAIN MOISTURE AND LIQUIDS HIGH VOLTAGE RISK OF ELECTRIC SHOCKH IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment e Never let the power cable come into contact with other If the equipment is dropped or damaged disconnect the cables Handle the power cable and all mains voltage mains power supply immediately and have a qualified connections with particular caution engineer inspect the equipment before operating again e Never remove warning or informative labels from the unit If the equipment has been exposed to
2. drastic Do not open the equipment and do not modify the unit temperature fluctuation e g after transportation do not connect power or switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature e Do not connect this equipment to a dimmer pack e Do not switch the equipment on and off in short intervals as this will reduce the system s life e Only use the equipment indoors If your product fails to function correctly stop use e Do not expose to flammable sources liquids or gases immediately Pack the unit securely preferably in the e Always disconnect the power from the mains when original packing material and return it to your Pro Light equipment is not in use or before cleaning Only handle dealer for service the power cable by the plug Never pull out the plug by pulling the power cable Repairs servicing and power connection must only be e Make sure that the available voltage is between carried out by a qualified technician THIS UNIT CONTAINS 100 240V 50 60Hz NO USER SERVICEABLE PARTS e Make sure that the power cable is never crimped or WARRANTY One year from date of purchase damaged Check the equipment and the power cable periodically Only use fuses of same type and rating OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damag
3. the MODE button on the rear of the unit to show SL ALI on the LED display and press the ENTER button to confirm the setting The units will now run in sequence with the master unit To exit out of any of the above options press the MODE button Please ensure that all slave units are set to the same DMX channel mode as the master unit www prolight co uk Intense 9HEX10 LED Slim Par User Manual s8 Operating instructions Sound active mode To access the sound active mode press the MODE button on the rear of the unit to show SUG on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the sound sensitivity level from SHOO SHJ and press the ENTER button to confirm the setting Value 00 31 00 low 99 high To exit out of any of the above options press the MODE button Auto mode To access the auto mode press ENTER until the display shows Huo on the LED display The fixture will now run through its built in programs NOTE The user can set up the speed and flash speed forPr G2 Pr 76 under the built in programs mode Changing this here will then take effect when running auto mode To exit out of any of the above options press the MODE button NOTE This fixture has a thermal protection function The fixture will automatically enter into a self protection state and the LED display will flash r E if the thermal pr
4. 0 2244 978 559 375 Power consumption 98W at Power supply 100 240V 50 60Hz F T1 5A 250V o EE a SE A ey Ses Dimensions 295 x 260 x 93mm Weight 2 6kg Om 1m 2m 3m 4m 5m Order code LEDJ254A 260mm 93mm Po maT Tf N B GON 3 O 3 ae www prolight co uk Intense 9HEX10 LED Slim Par User Manual 3 Technical specifications INTENSE 9HEX10 LED SLIM PAR www prolight co uk DMX IN POWER IN POWER OUT DMX OUT 100 240V 50 60Hz 01 Bracket 05 Function buttons 09 IEC power in socket 02 Bracket tightening knobs 06 Safety bond point 10 IEC power out socket E E N O3 Earth point 07 DMX input socket 11 Fuse F1A 250V Ax user manual 04 LED display 08 DMX output socket www prolight co uk Intense 9HEX10 LED Slim Par User Manual 4 Operating instructions DMX channel mode Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show In this mode you will be able to control each individual trait of the fixture and each fixture independently To access the DMX channel mode press the MODE button on the rear of the unit to show d UG on the LED display Now use the UP and DOWN buttons to set the desired DMX address Now press the ENTER button to choose one of the 6 8 or 10 DMX channel modes press the ENTER button to confirm the setting To exit out of any of the above options press the M
5. 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR socket Pin 1 GND screen Pin 2 Signal Pin 3 Signal 5 pin XLR socket 3 pin XLR socket Pin 1 GND screen Pin 1 GND screen 8 Pin 2 Signal Pin 2 Signal Pin 3 Signal Pin 3 Signal Pin 4 N C Pin 5 N C www prolight co uk Intense 9HEX10 LED Slim Par User Manual 11 WEEE notice Correct Disposal of this Product Waste Electrical amp Electronic Equipment Applicable in the European Union and other European countries Si with separate collection systems This marking shown on the product or its literature indicates that it should not be disposed of with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal C fe www prolight co uk Intense 9HEX10 LED Slim Par User Manual 12 Opti
6. ED Slim Par User Manual 10 DMX setup Notice Be sure to follow the diagrams below when making your own cables Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out DMX 512 in 3 pin XLR 3 pin XLR EN MORE EN RNR SORES OM EE OE XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground 2 cold Pin 1 Ground Q Pin 2 Negative 3Hot 3Hot Pin 3 Postive Special note Line termination When longer runs of cable are used Termination reduces signal transmission you may need to use a terminator on problems and interferance it is always the last unit to avoid erratic behaviour advisable to connect a DMX terminal _ resistance 120 Ohm 1 4 W between pin 2 Using a cable terminator will decrease DMX and pin 3 DMX of the last fixture the possibilities of erratic behaviour 3 pin Order ref CABL9O 5 pin Order ref CABL89 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion F B A E 5 pin XLR socket Pin 1 GND screen Pin
7. ODE button 2 channel mode 119 135 Cyan G 255 B 255 136 152 Lavender R 170 B 210 153 169 170 186 187 203 204 220 Orange R 200 A 200 221 237 238 255 Value www prolight co uk Intense 9HEX10 LED Slim Par User Manual 5 Sh 3 channel mode 1 2 3 000 255 Flash speed 0 100 1Hz 20Hz a foo 2 foo foos ci0 ea oS 026030 amer O wooo S Amber uv Cyan G 255 B 255 Lavender R 170 B 210 Magenta R 255 B 90 UV 255 081 150 Colour jumping speed Slowest 081 changes every 8 secs Fastest 150 changes every 0 3 secs 151 220 Colour fading speed Slowest 151 changes every 8 secs Fastest 220 changes every 0 3 secs 221 255 Sound control mic sensitivity 3 channel mode 4 channel mode Red 0 100 Green 0 100 3 000 258 5 channel mode 6 channel mode 000 255 Red 0 100 Green 0 100 Green 0 100 e O 000 255 White 0 100 000 255 Amber 0 100 000 000 255 White 0 100 000 255 Amber 0 100 000 255 UV 0 100 Operating instructions 4 channel mode Channel value Function 000 255 Green 0 100 000 255 Blue 0 100 000 255 Amber 0 100 www prolight co uk Intense 9HEX10 LED Slim Par User Manual 6 amp 6 Sh 8 channel mode 10 channel mode Value 000 255 000 255 Red 0 100 000 255 Green 0 100 000 255 Blue 0 100 000 255 e 000 265 uv os
8. e and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns and electric shocks etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and or property www prolight co uk Intense 9HEX10 LED Slim Par User Manual 2 Product overview amp technical specifications Intense 9HEX10 LED Slim Par Powered by 9 x 10W RGBWAUV LEDs within a compact die cast chassis the Intense 9HEX 10 provides a smooth wash of vibrant colour Featuring 6 in 1 colour LEDs this fixture advances from standard RGB colour mixing with the addition of white for pastel shades amber for rich warm tones and UV for intense hues The convection cooled chassis ensures silent running and features mounting points for the optional barn door gel frame kit LEDJ253A e 9x 10W 6 in 1 colour LEDs RGBWAUV e Beam angle 25 e 4 2kHz refresh rate e DMX channels 2 3 3 4 4 5 6 8 or 10 selectable e Static colour colour change colour fade auto run sound active and master slave modes e O 100 dimming with variable strobe e Bracket allows for multiple rigging and floor standing applications e 4 push button menu with LED display e IEC power in out sockets e 3 pin XLR in out sockets e Convection cooled e Optional barn door gel frame kit LEDJ253A Specifications Intense 9HEX10 25 Lux 865
9. in Pr press the ENTER button and then use the UP and DOWN buttons to go through the static colours Press the ENTER button to confirm the setting then use the UP and DOWN buttons to select and value from F500 F599 for the strobe feature Press the ENTER button to confirm the setting To exit out of any of the above options press the MODE button Programs Static colours Static colour 6 colour fade Multicolour fade 3 b Blue 9 b Bright Pink iGi b Rose Pink i 19b Light Blue Iru Salmon Pink Multicolour illusion 6 colour change Multicolour change 139u Pastel Green A r 9 Green Yellow 4bu Pastel Blue Suu Warm White 6c u Full on White Static colour mode To access the static colour mode press ENTER until Cof r shows on the LED display Press the ENTER button and the LED display will show r Z Z 5 Now use the UP and DOWN buttons to select the brightness between r OODO r 255 Press the ENTER button and repeat for green blue white amber and UV Value 000 255 000 low 255 high To exit out of any of the above options press the MODE button Master slave mode To set the master unit press the MODE button on the rear of the master unit then select your desired program sound active auto static colour or one of the built in programs To set the other units in slave mode press
10. onal accessories Please contact your local retailer to purchase these accessories Optional barn door gel frame Order code LEDJ253A Optional Quad Case Holds 4 x fixtures Order code CASE65 To keep up to date on the latest accessories and product range additions please visit www prolight co uk www prolight co uk Intense 9HEX10 LED Slim Par User Manual 13
11. oo 000 255 000 255 i 001 041 042 083 084 125 126 167 168 209 210 241 242 255 8 000 255 Strobe slow fast 9 Static colour channel 8 is 001 041 017 033 Green 034 050 051 067 White 068 084 085 101 UV 102 118 119 135 136 152 153 169 170 186 Magenta R 255 B 90 UV 255 187 203 Turquoise G 255 B 180 UV 255 204 220 Orange R 200 A 200 221 237 Cool white R 70 G 190 B 255 A 200 238 255 Warm white R 230 G 255 B 255 A 255 W 255 000 255 Program speed when channel 8 is 001 241 000 255 Sound sensitivity 0 31 when channel 8 is 242 255 000 255 Strobe slow fast www prolight co uk Intense 9HEX10 LED Slim Par User Manual 7 Operating instructions Built in program mode To access the built in program mode press MODE until the display shows Pr I on the LED display Use the UP and DOWN buttons to select a program from Pr g 1 P re Press the ENTER button to confirm the setting To change the speed of the selected program press the ENTER button and then use the UP and DOWN buttons to select any value from SP OO 57494 Press the ENTER button to confirm the setting then use the UP and DOWN buttons to select and value from FSU0 F 544 forthe strobe feature Press the ENTER button to confirm the setting In Pr you are able to set a specific static colour When
12. otection is activated Switch off the fixture and leave to cool down Should the problem reoccur please contact your local dealer for service and support Menu system Built in program Pr i Static colour Pr dc 6 colour fade Pr 03 Multicolour fade P24 Multicolour illusion Pr 25 6 colour change P 46 Multicolour change SPOGOG 5P99 speed FSO0 F599 flash Static colour mode Sound active mode DMX mode Address setting un m E wn E 5 uw co CH 4CH 4CH CH 10CH T S I oo w C C a N 3 6 21 00 a A uw a mu E www prolight co uk Intense 9HEX10 LED Slim Par User Manual 9 DMX setup Setting the DMX address The DMX mode enables the use of a universal DMX controller Each fixture requires a start address from 1 512 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 105 and 106 Choose a start address so that the channels used do not overlap E g the next unit in the chain starts at 107 DMX 512 DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial da
13. ta that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA cable DMX cable requirements for DMX operation This fixture can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input output see image below Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers Please quote CABL10 2m CABL11 5m CABL12 10m Also remember that DMX cable must be daisy chained and cannot be split www prolight co uk Intense 9HEX10 L