1. Recreation Initial setup gt custom Other features To access more features back on the Settings menu you can also select Features Other which will provide a new screen showing various options that can be turned On or Off and activated for further customization BOB DB a i ow Settings Q f Y Li FEATURES Grip Patterns SS Real time graph of signals Hand health check grip chip setup Control Strategy Dual site Differential GENERAL 8 OB DB a Delay 0 50 seconds NATURAL HAND Use natural hand AUTO GRASP Use auto grasp High activation mode Low activation mode ROTATING THUMB Rotate thumb on exit PULSING VARI GRIP ON Use vari grip Delay 0 50 seconds NATURAL HAND Use natural hand AUTO GRASP Use auto grasp High activation mode v In addition to features that can be turned on or off and selected for further customization delay timing can be adjusted for vari grip and natural hand mode E EE Do PULSING VARI GRIP ON Delay 0 25 seconds Use vari arip ON 0 50 seconds 0 75 seconds NATURAL Hanu 1 0 seconds Use natural hand 1 25 seconds AUTO GRASP 1 50 seconds Use auto grasp ON High activation mode z E o u Other PULSING VARI GRIP ON Use vari grip ON Delay 0 50 seconds NATURAL HAND 30 seconds Use natural ha Delay 0 seconds Finge
2. Single site Voluntary Closing The presence of the EMG signal that exceeds the threshold setting results in the hand closing Any signal below the threshold or removal of the signal will result in the hand opening Language System default Languages The default language setting is English Select Language to change the settings to the appropriate language N Settings Q bd w Other Language Real time graph of signals System default Hand health check English Control Strategy Fran ais Dual site Differential Deutsch GENERAL anguage Italiano System default Espa ol About Connected hand app T amp C s Touch Bionics on the web Find more information About The final option on the Settings menu is the About option Tapping this brings up a screen displaying information about the patient s prosthesis and the application The unique security code will also be found here JON h 10 39 O N Settings b About Q Se Fo HAND INFORMATION m Other Real time graph of signals APP INFORMATION Hand health check Control Strategy Dual site Differential GENERAL Language System def About connected hand app T amp C s Find more information Terms and conditions Touch Bionics on the web Tapping Sign out will end the session and require you to sign in again for your next session For easy access we recommend you remain signed in
3. If the hand should fail to connect to the app due to loss of power proximity with the Android device or other reasons the following screen will appear The hand failed to connect please turn the hand off and back on before trying to connect again Search In this instance turn off the i limb access for 4 seconds then turn back on Tap the Search button to reconnect Favorites screen Here you can assign groups of grip patterns and triggers a single name to make them easily accessible with a single tap ii k r ia 09 41 S Favorites Connect to i ligf access von A gt Home S Recreation Note To access the Favorites screen at any time simply tap the heart icon Tapping on the favorite will instantly activate those settings on the device and display a quick reminder of what grip patterns and triggers are included b Reminder Features being activated Thumb precision pinch Y closed Nw Hold open Creating a new favorite Everyone has their own set of features and triggers that they prefer to use for different tasks To set up a group of features tap the settings icon in the top right corner iil a a r ia 09 41 s Favorites Connected to i limb access vor A gt Home S Recreation On the Settings menu tap Features Grip patterns to access the full set of grips available for selection Fr
4. Standard Standard Thumb precision Thumb precision precision pinch precision pinch pinch opened pinch closed opened closed Standard 3 jaw Standard 3 jaw Thumb 3 jaw Thumb 3 jaw chuck tripod chuck tripod chuck tripod chuck tripod opened closed opened closed Thumb park Thumb park Lateral grip Index point continuous quick touch i limb access bionics Connection After signing in you will be brought to the connec tion screen where you will tap the device to which you want to connect Jou A Connect A0001 Tap a device above to connect You may need to turn the hand off and back on for it to appear in the list Do not use the software to access connect to control or manipulate any device or data without the full knowledge consent and authorization of the owner of such device or data Searching for another device If you need to connect to a different device simply tap the magnifying glass in the top left corner of the app and it will search for any devices in the area In order for you to connect to a patient s device they will need to tell you their 4 digit serial number located proximal to the base of the thumb on the connection plate If the patient is using a flexion wrist the serial number will appear at the base of the thumb You will be prompted to enter this after selecting the patient s device Authorized use only Please enter the 4 digits of the device s serial number
5. hand health check from the Settings menu brings up the option to run a test on your device to ensure that everything is running as it should Tapping Run health check will run through a series of checks and will alert Touch Bionics to contact you if anything requires attention on your patient s i limb device D Settings FEATURES Grip Patterns Other Real time graph of signals Hand health check Control Strategy Dual site Differential GENERAL Language English Note You must be Checking power to the hand Passed Z Checking battery life Passed connected to the Internet Checking digit function Passed using Wi Fi or cellular to run a hand health check Real time graph Selecting the Real time graph of signals option from the Settings menu brings up a graph showing the patients input signals on the screen This visual information can be helpful when trying to activate certain triggers or work on controlling activation and relaxation of signals Turn the Android device horizontally to view the graph Tap the graph to adjust the gain and threshold settings You can save an image of the Real time Graph by tapping the camera on the top right of the screen Saved indicates that an image was successfully captured FEATURES Grip Patterns Other Real time graph of signals Hand health check Input channel 1 Control Strategy ne Dual site Differenti
6. bionics bIosIM Quick Reference Guide for i limb touch devices bionics Contents 1 2 5 6 Welcome and important points Getting started Activation Firmware Update i limb ultra revolution 12 12 13 14 15 16 22 25 27 39 41 43 46 48 49 52 53 54 55 56 Connection Searching for another device Authorized user access Connection failed Quick grips and my grips screen my grips configuration Configuring my grips using QR codes Sharing my grips with Touch Bionics grip chip setup Favorites screen Creating a new favorite Assigning triggers Editing favorites Settings Other features Hand health check Real time graph Control strategy Languages About Contents cont i limb ultra 58 58 59 60 61 63 65 68 70 71 74 15 76 T1 78 Connection Searching for another device Authorized user access Connection failed Favorites screen Creating a new favorite Assigning triggers Editing favorites Settings Other features Hand health check Real time graph Control strategy Languages About i limb access 80 80 81 82 83 85 87 90 92 Connection Searching for another device Authorized user access Connection failed Favorites screen Creating a new favorite Assigning triggers Editing favorites Settings Contents cont 93 Hand health check 94 Real time graph 95 Control strategy 96 Languages 97 About i limb digits 99 Connection 99 S
7. 1 0 seconds Choose the total amount of time allowed to accomplish multiple impulses that will activate a trigger a Ea Once you have selected a group of grip patterns and triggers that you would like to be able to access as a single group of favorites tap on the icon in the top right of the Features screen A screen will appear that allows you to choose a name and icon Note A red symbol designating the AJ d assigned trigger on will appear at the a a J Ay N top right of the grip mens a pattern s GOSS favorite gdo anal _ i a a oat gt Icon qwerty uioop PoP PP Pe bPeb got gt zxexevbornrm a Next After you tap Save this favorite will now be added to your list on the Favorites screen of the biosim app and can be activated in the future with a single tap ii ia 10 09 Favorites Rm Q ad o Connected to i limb digits von A gt Home Recreation 108 Editing favorites Tap the edit button at the top right and the screen changes to look like the one seen below Here you can tap the red button to delete the favorite grab the handles and drag to change the order of the list and tap the name of the entry to edit the favorite A Home 6 Recreation 6 Recreation Here you can edit preferences of the selected favorite including the name associated icon and grip pattern association Tap the ind
8. and display a quick reminder of what grip patterns and triggers are included O Reminder Features being activated Thumb precision pinch Y closed h d Hold open Creating a new favorite Everyone has their own set of features and triggers that they prefer to use for different tasks To set up a group of features tap the Settings icon in the top right corner iil Favorites Recreation Initial Setup On the Settings menu tap Features Grip patterns to access the full set of grips available for selection Exactly the same as biosim on your computer from this screen you can choose the features that you would like to group together ae 7 Oo Settings Settings Q 9 oi FEATURES FEATURES Grip Patterns Grip Patterns Other Other Real time graph of signals Real time graph of signals Hand health check Hand health check Control Strategy Control Strategy Dual site Differential Dual site Differential GENERAL GENERAL Language Language System default System default Assigning triggers Tapping on a grip pattern will bring up a menu that allows you to assign one of the four possible triggers for activating it You may also set detect time for Hold open and Co contraction as well as duration and period times for Double Impulse and Triple Impulse lHold open DETECT TIME SECONDS o contraction 2 seconds Triple impulse i Choose the amount of
9. code library can be accessed online at www touchbionics com qrcodes When ready to download and program a my grip tap an unassigned my grip to access the Trigger menu K Saving screenshot E OH b Features t Trigger Hold open i 2 Co contraction i p Double impulse i a d Triple impulse i 2 Configure my grip Once on the Trigger menu tap the Scan QR to import my grip option After tapping Scan QR to import my grip the camera function will be activated Note if you have a cover on your mobile device ensure it is not covering the camera lens Point your mobile device camera at the desired QR code Trigger PHONE Hold open i Co contraction i Double impulse i Triple impulse i Configure my grip Scan QR to import my grip Share my grip Once the QR code is scanned successfully you will be brought back to the Trigger menu From here you can further customize any my grip as preferred Sharing my grips with Touch Bionics Users may share custom my grips to be considered for inclusion in Touch Bionics QR code library To share your my grip with Touch Bionics tap a my grip to access the Trigger menu Next tap Share my grip The custom my grip will be transmitted to Touch Bionics app cloud ee 4 P fl Saving screenshot Trigger Trigger PHONE PHONE Hold open i Hold open i Co contraction i Co contra
10. ia npe ET TES Other Real time graph of signals Hand health check grip chip setup Thumb park Control Strategy Dual site Differential GENERAL eee Assigning triggers Tapping on a grip pattern will bring up a menu that allows you to assign one of the four possible triggers for activating it You may also set detect time for Hold open and Co contraction as well as duration and period times for Double Impulse and Triple Impulse TE So b Hold open DETECT TIME SECONDS Hold open o contraction 2 seconds Double impulse i Triple impulse i Choose the amount of time that the open signal must he digits before the be maintaine hold open trigger is activated gt Trigger Duration milliseconds Standard precision pinch opened Hold open w i Co contraction 300 milliseconds Double impulse riple impulse 1 0 seconds Choose the total amount of time allowed to accomplish multiple impulses that will activate a trigger Once you have selected a group of grip patterns and triggers that you would like to be able to access as a single group of favorites tap on the icon in the top right of the Features screen A screen will appear that allows you to choose a name and icon Note A red symbol designating the assigned trigger will appear at the pattern s v I top right of the grip vw Saving scre
11. information b grip chip setup b grip chip setup Please contact Touch Bionics Customer Tap the grip chip sharply to wake it Service to enable grip chip support If you do not have grip chips please If you do not have grip chips please contact your prosthetist to purchase them contact your prosthetist to purchase them CS ea om m ES m You will be prompted to contact Touch Bionics if you do not currently have grip chip capability For grip chip compatible devices you will be prompted to awaken the grip chip by tapping sharply Active grip chips will be displayed on the grip chip setup page along with their grip chip number and battery level Tap the desired grip chip to which you want to connect grip chip Co tate thumb Index point grip chip index polat COM grip chip grip chip aish Omm Omm Donning or doffing cover Note You will see Not allocated on this device if you attempt to connect to a grip chip that has been previously programed with a favorite using a different Android device than the one you are currently using In this case you can still re configure the chip but will not see how it was previously configured The grip chip will then connect Once connected successfully the following screen will appear To rename the grip chip tap the name of grip chip field J O r 53 1 Of grip chip info grip chip info name of grip chip name
12. of grip chip Find grip chip quick grip quick grip favorite favorite my grip my grip sien Tapping Find grip chip will cause the selected grip chip to illuminate and make a sound This allows easy confirmation of which grip chip is connected Tap on one of the options to assign quick grip favorite or my grip to a grip chip Selecting Quick grip will allow you to select a quick grip option to assign to the grip chip Of b Choose grip O8 b grip chip info name of grip chip i grip chip Find grip chip quick grip favorite Not allocated Oo i Choose grip After selecting a quick grip to assign tap Save when arriving back to the grip chip info screen The grip chip is now shown with its name assignment number and battery level Selecting Favorite will allow you to select a saved favorite option to the designated grip chip ng screenshot i 09 00 Favorite b grip chip info Connected to Himb ultra revolution name of grip chip grip chip Find grip chip quick grip amp Recreation Not allocated Initial Setup ROS Work my grip Not allocated After selecting a favorite to assign tap Save when arriving back to the grip chip info screen The grip chip is now shown with its name assignment number and battery level Selecting my grip will allow you to select a my g
13. presence of the EMG signal that exceeds the threshold setting results in the hand opening Any signal below the threshold or removal of the signal will result in the hand closing Single site Voluntary Closing The presence of the EMG signal that exceeds the threshold setting results in the hand closing Any signal below the threshold or removal of the signal will result in the hand opening Languages The default language setting is English Select Language to change the settings to the appropriate language _ Settings Q bd w Other Language Real time graph of signals System default Hand health check English Control Strategy Fran ais Dual site Differential Deutsch GENERA anguage Italiano System default Espa ol About Connected hand app T amp C s Touch Bionics on the web Find more information About The final option on the Settings menu is the About option Tapping this brings up a screen displaying information about the patient s prosthesis and the application The unique security code will also be found here i gt 09 24 ToN Settings b About Q fo HAND INFORMATION Other Real time graph of signals APP INFORMATION Hand health check Control Strategy Dual site Differential GENERAL Language System default About Connected hand app T amp C s Terms and conditions Touch Bionics on the web Find more infor
14. reasons the following screen will appear The hand failed to connect please turn the hand off and back on before trying to connect again Search In this instance turn off the i limb ultra revolution for 4 seconds then turn back on Tap the Search button to reconnect Quick grips and my grips screen After connecting to biosim you will see the Quick Grips and my grips screens Here you get instant access to 24 quick grip patterns and 12 custom my grips with a single tap Tapping a grip icon immediately puts the device into that mode d 2 d ob Note To exit that grip simply tap the same icon d 2 d 2 to return to the full hand mode or use one of your 2 2 8 2 programmed triggers my grips configuration my grips allows you to configure up to 12 additional custom grips and can be used with any trigger or grip chips FEATURES Grip Patterns Other Hand health check grip chip setup O Ay AJ Real time graph of signals l Control Strategy Dual site Differential ee o GENERAL To configure my grips tap the settings icon after connecting to the biosim app Once on the settings screen tap Features Grip patterns to access the full set of standard grips amp my grips available for selection All unassigned my grips will have no name specified until one is assigned by the user amp CE E S i e CA Tap one of the blank amp 2 2 8 my gr
15. the Settings icon on the first screen amp Settings WIRELESS amp NETWORKS e Wi Fi Bluetooth Data usage More DEVICE dH Sound Display Storage Battery EB Apps Next go to the Android Play Store via the icon To search for the biosim app type Touch Bionics or biosim in the search tab and download the app to your Android device Note a Google ID will be required to download the app If you do not have one please create an account by logging on to the Google website E oe APPS WIDGETS Clinicians may also download my i limb which is the patient version of the biosim app Use the term my i limb when searching the Google Play Store Note Search for biosim and my i limb in the Google Play Store Upon downloading the biosim mobile app an icon will appear on your mobile device s screen Tap on it to start the app ae APPS WIDGETS gt Calculator Calendar Clock Downloads Email A Gallery Hangouts Activation The first time you connect to biosim you will see the Sign in screen Here you will need to enter the email address and password that you use when you log in on the Patient Care Pathway on Touch Bionics web site If you need to create an account you may also do so by selecting Register on the screen below You will need to activate your account by confirming the email sent to the email acc
16. time graph of signals option from the Settings menu brings up a graph showing your input signals on the screen This visual information can be helpful when trying to activate certain triggers or work on controlling activation and relaxation of signals e Turn the Android device horizontally to view the graph Tap the graph to adjust the gain and threshold settings You can save an image of the Real time Graph by tapping the camera on the top right of the screen Saved indicates that an image was successfully captured FEATURES Grip Patterns Other Real time graph of signals Hand health check Input channel 1 grip chip setup San m S Control Strategy Theeshotd o20v ae SS Input channel 2 GENERAL Gain 0 Theeshotd 020V 4 To exit the graph simply turn the Android device back to a vertical position or tap Done Control strategy Control strategy is the method by which the i limb device responds to the input signals This option allows the clinician to switch how the device responds according to 5 options E o m Settings Q f ad w FEATURES Grip Patterns Other Real time graph of signals Hand health check grip chip setup Control Strategy Dual site Differential ou Control Strategy Dual site Differential The strength of the input hand operation if opens If signal determines onger the hand we hand closes Dual site Fi
17. 30 seconds Dual site Differential GENERAL Finger positions Language AUTO GRASP System default Delay 0 50 seconds NATURAL HAND Use natural hand on Finger positions AUTO GRASP Use auto grasp High activation mode z Low activation mode Other features In addition to features that can be turned on or off and selected for further customization timing delay can be adjusted for vari grip and natural hand mode i gt o gt PULSING VARI GRIP ON Delay 0 25 seconds Use vari grip ON 0 50 seconds Delay 9 50 seconds 0 75 seconds NATURAL HAND 1 0 seconds Use natural hand on 1 25 seconds Delay 30 seconds 1 50 seconds Finger positions AUTO GRASP N Other PULSING VARI GRIP ON Use vari grip on Delay 0 50 seconds NATURAL HAND 30 seconds Use natural hand Delay 0 seconds Finger positions AUTO GRASP Other features Finger positions can also be selected for natural hand and default values set for i limb skin active or i limb skin natural covers Dou Finger positions FINGER POSITIONS Delay 0 50 sec ds KaU eecond Thumb NATURAL HAND 70 Use natural hand ON Oper Close Index 40 Jpen lose Finger positions a Middle AUTO GRASr 40 Use auto grasp Oper Close Ring High activation mode z 40 Open cl Low activation mode Finger positions Middle Open Close Ring Open Close
18. Little 40 e Open Close DEFAULTS Load defaults for active skin Load defaults for natural skin Hand health check Selecting Hand health check from the Settings menu brings up the option to run a test on the device to ensure that everything is running as it should Tapping Run health check will run through a series of checks and will alert Touch Bionics to contact you if anything requires attention on your patient s i limb device Settings FEATURES Grip Patterns Other Real time graph of signals Hand health check Control Strategy Dual site Differential GENERAL Language System default e Hand health check Checking power to the hand Passed connected to the Internet Checking battery life Passed Checking digit function Passed using Wi Fi or cellular to run a hand health check Real time graph Selecting the Real time graph of signals option from the Settings menu brings up a graph showing the patients input signals on the screen This visual information can be helpful when trying to activate certain triggers or work on controlling activation and relaxation of signals Turn the Android device horizontally to view the graph Tap the graph to adjust the gain and threshold settings You can save an image of the Real time Graph by tapping the camera on the top right of the screen Saved indicates that an image wa
19. al Sain 0 e GENERAL Theeshots www 8 Language Input channel 2 System detal 4 To exit the graph simply turn the Android device back to a vertical position or tap Done 115 Control strategy Control strategy is the method by which the i limb device responds to the input signals This option allows the clinician to switch how the device responds according to 5 options oN Settings Control Strategy Dual site First Over The presence of the signal A before signal B results in the hand opening The presence of the signal B before signal A results in the hand closing Both signals must fall below the configured threshold before hand operation changes Grip Patterns Q Q Oa Dual site Differential The strength of the input signal determines hand operation If signal A is stronger the hand FEATURES opene If signal B is stronger the hand closes Other Single site Alternating The presence of a signal over the defined threshold results in the hand opening The next presence of the signal over the defined threshold results in the hand closing Real time graph of signals Hand health check Single site Voluntary Opening The presence of the EMG signal that exceeds the threshold setting results in the hand Control Strategy opening Any signal below the threshold or Dual site Differential removal of the signal will result in the hand ins closing Single site Voluntary Closing T
20. cted to i limb digits von AN Home S Recreation Initial Setup On the Settings menu tap Features Grip patterns to access the full set of grips available for selection Exactly the same as biosim on your computer from this screen you can choose the features that you would like to group CFn 24 Hom Settings Features Q ad Loi FEATURES Y y Y j D F F 4 recisenginh precisunpnch pachopaned piach cloned opened closed svans Real time graph of signals Hand health check Control Strategy Dual site Differential GENERAL Language System default e o Assigning triggers Tapping on a grip pattern will bring up a menu that allows you to assign one of the four possible triggers for activating it You may also set detect time for Hold open and Co contraction as well as duration and period times for Double Impulse and Triple Impulse Hold open Co contraction Triple impulse i B 14 01 gt Held open E DETECT TIME SECONDS 2 seconds Choose the amount of time that the open signal must be maintained bey full stall of the digits before the hold open trigger is tivated b Trigger Standard precision pinch opened Hold open A Co co Double impulse Triple impulse Impulse Duration milliseconds 300 milliseconds f time allowed for the eshold and back below
21. ction i Double impulse i Double impulse i Triple impulse i Triple impulse i Configure my grip Configure my grip Scan QR to import my grip Scan QR to import my grip a Sharing grip with Touch Bionics Note Internet connection is needed to share my grips Once complete a message will appear confirming that the my grip was successfully shared with Touch Bionics i Trigger PHONE Hold open i Co contraction Double impulse i Triple impulse i Configure my grip Scan QR to import my grip Share my grip Sharing successful grip chip setup For first time use you will need to physically tap the grip chip on a hard surface to activate it You will hear an audible alert when activated successfully Upon connection to the biosim or my i limb apps tap the settings icon a i o J i of Quick Grips Settings Q f Lo Real time graph of signals Hand health check grip chip setup Control Strategy Dual site Differential GENERAL Language English About Connected hand app T amp C s Touch Bionics on the web d e Find more information On the settings page tap grip chip setup to program a grip chip Oo Settings Q F oi Real time graph of signals Hand health check grip chip setup Control Strategy Dual site Differential GENERAL Language English About Connected hand app T amp C s Touch Bionics on the web Find more
22. d use only Please enter the 4 digits of the device s serial number Note If you do not have a wristband you can locate the device serial number in biosim If the digits device should fail to connect to the app due to loss of power proximity with the Android device or other reasons the following screen will appear ta 10 05 The hand failed to connect please turn the hand off and back on before trying to connect again Search In this instance turn off the device for 4 seconds then turn back on Tap the Search button to reconnect Favorites screen Here you can assign groups of grip patterns and triggers a single name to make them easily accessible with a single tap ii i BB id 10 07 s Favorites AA Connect tatgnisimb digits vor AN Home Recreation Initial Setup Note To access the Favorites screen at any time simply tap the heart icon Tapping on the favorite will instantly activate those settings on the device and display a quick reminder of what grip patterns and triggers are included ae b Reminder Features being activated Thumb precision pinch Y closed SS Hold open Creating a new favorite Everyone has their own set of features and triggers that they prefer to use for different tasks To set up a group of features tap the settings icon in the top right corner ii a r id 10 07 S Favorites Conne
23. earching for another device 100 Authorized user access 101 Connection failed 102 Favorites screen 104 Creating a new favorite 106 Assigning Triggers 109 Editing favorites 111 Settings 112 Other features 114 Hand health check 115 Real time graph 116 Control strategy 117 Languages 118 About 119 Health amp Safety 119 Other Important Points Welcome and Important Points Welcome to the mobile world of Touch Bionics The biosim mobile application will enable you to quickly and easily access and change features on i limb devices Important points to note e The biosim app must be downloaded from the Android Play Store e A Wi Fi or cellular connection is needed to download the app receive updates or run hand health check e Your Android device connects to an i limb via a Bluetooth connection which is automatically established when you start the biosim app The biosim mobile app is compatible with the following devices Samsung Galaxy S5 Google Nexus 5 Motorola X e Minimum version of android required is 4 3 jelly bean e To exit the application at any time simply press the main Home button on your Android device For general instructions on using your Android device read your devices user manual provided by Android The first time you use your device you will need to be connected to the Internet via cellular or Wi Fi connection You can connect to a Wi Fi network by tapping on
24. en Saved indicates that an image was successfully captured FEATURES Grip Patterns Other Real time graph of signals Hand health check Input channel 1 Control Strategy ne GENERAL Theeshotd ony gt Language Input channel 2 System default To exit the graph simply turn the Android device back to a vertical position or tap Done Control strategy Control strategy is the method by which the i limb device responds to the input signals This option allows the clinician to switch how the device responds according to 5 options E Settings Q ad Loi FEATURES Grip Patterns Other Real time graph of signals Hand health check ontrol Strategy Dual site Differential GENERA Language System default oun Dual site Differential The strength of the input signal determines hand operation If signal A is stronger the hand opens If signal B is stronger the hand closes Dual site First Over The presence of the signal A before signal B results in the hand opening The presence of the signal 8 before signal A results in the hand closing Both signals must fall below the configured threshold before hand operation changes Single site Alternating The presence of a signal over the defined threshold results in the hand opening The next presence of the signal over the defined threshold results in the hand closing Single site Voluntary Opening The
25. enshot Ar pE Select Icor e s favorite a custom 6 4 aw z amp Icon qwertyuioop a ksi ai DE ig in gt zxcv b nma nz amp After you tap Save this favorite will now be added to your list on the Favorites screen of the biosim app and can be activated in the future with a single tap Favorites Q i od i Connected to i limb ultra revolution vn an Home amp Recreation Initial setup Editing favorites Tap the edit button at the top right and the screen changes to look like the one seen below Here you can tap the red button to delete the favorite grab the handles and drag to change the order of the list and tap the name of the entry to edit the favorite Favorites Q f Y Connected to i limb ultra revolution Ee Work E Work 6 Connected to i limb ultra revolution A Home v xX Home 6 Recreation amp Recreation Initial setup v Initial setup To edit any of your favorites simply go into the favorite you would like change Here you can modify the name icon grip pattern features and triggers b Edit Favorite favorite Work Pa Features When editing features you must return to the Edit Favorite screen above and tap Save to confirm your changes Settings To access the Settings menu tap the settings icon on the top right of the Favorites page
26. ff and back on again to complete the update Please turn the device off and back on and then press the button below to reconnect Reconnect On After powering off and on tap Reconnect to continue using the biosim app Y i limb ultra touch revolution bionics Connection After signing in you will be brought to the con nection screen where you will tap your device to connect Devices R9999 Tap a device above to connect You may need to turn the hand off and back on for it to appear in the list Do not use the software to access connect to control or manipulate any device or data without the full knowledge consent and authorization of the owner of such device or data Searching for another device If you need to connect to a different device simply tap the magnifying glass in the top left corner of the app and it will search for any devices in the area In order for you to connect to a patient s device they will need to tell you their 4 digit serial number located proximal to the base of the thumb on the connection plate If the patient has a flexion wrist the serial number will appear at the base of the thumb You will be prompted to enter this after selecting the patient s device Authorized use only Please enter the 4 digits of the device s serial number If the hand should fail to connect to the app due to loss of power proximity with the Android device or other
27. he presence of the EMG signal that exceeds the threshold setting results in the hand closing Any signal below the threshold or removal of the signal will result in the hand opening Languages The default language setting is English Select Language to change the settings to the appropriate language Mi Settings Other Real time graph of signals Hand health check Control Strategy Dual site Differential anguage English Connected hand app T amp C s Touch Bionics on the web Find more information Checking battery About The final option on the Settings menu is the About option Tapping this brings up a screen displaying information about the patient s prosthesis and the application The unique security code will also be found here a Settings OQ Q oS Fe HAND INFORMATION Other Real time graph of signals APP INFORMATION Hand health check Control Strategy Dual site Differential GENERAL Language English Terms and condition About Connected hand app T amp C s Touch Bionics on the web Find more information ee ee EE Tapping Sign out will end the session and require you to sign in again for your next session For easy access we recommend you remain signed in Health and safety For health and safety information regarding i limb devices please refer to the respective user manuals that can be f
28. ip options to begin creating a custom my grip Tapping on the desired my grip will bring up the my grip configuration page that allows you to configure a my grip and assign a desired trigger Tap Configure my grip to continue i Oo M Trigger Hold open Gi Co contraction i Double impulse Gi Triple impulse i Scan QR to import my grip Next you will be able to assign a name to a my grip Tapping the enter name field will allow you to customize the name of your my grip SHON my grip setup NAME OF MY GRIP NAME OF MY GRIP Tap the button below to begin configuring the grip Tap the button below to begin configuring the grip It is recommended that you create my grips when Itis recommended that you create my grips when your prosthesis has a fully charged battery your prosthesis has a fully charged battery Opening hand After creating a name tap the start button to begin the my grip configuration process This will fully open the hand Note It is recommended that users configure my grips when the prosthesis has a fully charged battery Next apply a close signal to rotate the thumb to a desired position as noted Tap Continue when finished oe 7 13 2 i ow my grip setup my grip setup NAME OF MY GRIP NAME OF MY GRIP My grip 12 My grip 12 Apply a close signal to rotate the thumb into the Apply a close signal to rotate the thumb into the desired positio
29. ividual field to edit iil b Edit Favorite favorite Work a lt o Features When editing features you must return to the Edit Favorite screen above and tap save to confirm your changes Settings To access the Settings menu tap the settings icon on the top right of the Favorites page ii CFR ia 10 09 S Favorites KZ Connected to i limb digits wn x Home Recreation a custom Other features To access more features back on the Settings menu you can also select Features Other which will provide a new screen showing various options that can be turned On or Off D dr 8 55 dOu Settings Other Q amp Fe PULSING VARI GRIP a FEATURES ON Grip Patterns Use vari grip ON Delay 0 50 seconds Real time graph of signals NATURAL HAND Use natural hand ON Hand health check Delay Control Strategy a seconds Dual site Differential GENERAL Finger positions Language AUTO GRASP English ca eat oa Other features In addition to features that can be turned on or off timing delay can be adjusted for vari grip wi b Other ON Delay Use vari grip 0 25 seconds Delay 0 50 seconds 0 50 seconds NATL p 0 75 seconds Use natural hand ON To secos Delay 1 25 seconds 30 seconds 1 50 seconds Finger positions AUTO GRASP Use auto grasp on Hand health check Selecting
30. l be prompted to disconnect Select yes to disconnect and save changes Select no to configure additional grip chips You will be prompted to disconnect after configuring each chip iil Settings Q d 0 FEATURES Grip Patterns Other Real time graph of signals Hand health check grip chip setup Grip chip ready Disconnecting from hand GENERAL a ey eile ee oe Helpful Tips When powering on hand please wait 5 seconds before connecting to biosim Programing must be completed within 10 seconds or grip chip will return to sleep mode If grip chip returns to sleep mode tap it once again to wake up and proceed with programming Once programed sleep mode is disabled Once programmed the grip chip will remain on until the battery life runs out You must naturally approach the grip chip and hold the i limb ultra revolution within 6 15cm inches from the grip chip The hand must be in the full open position to detect the grip chip It is important to remember that a natural movement is critical to quick and proper grip chip detection Running to a chip or hastily placing your hand near it may result in a connection delay Only hold open for grip chip detection when you are within 6 inches 15cm of grip chip Helpful Tips Each grip chip should remain at least 24 inches 61cm apart from one another Do not press the home button while hand is in process of co
31. mation Tapping Sign out will end the session and require you to sign in again for your next session For easy access we recommend you remain signed in a HO Standard Standard Thumb precision Thumb precision precision pinch precision pinch pinch opened pinch closed opened closed Standard 3 jaw Standard 3 jaw Thumb 3 jaw Thumb 3 jaw chuck tripod chuck tripod chuck tripod chuck tripod opened closed opened closed Thumb park Thumb park Lateral grip Index point continuous quick touch bionics i limb digits Connection After signing in you will be brought to the connec tion screen where you will tap the device to which you want to connect wl AN Connect Devices D0001 Tap a device above to connect You may need to turn the hand off and back on for it to appear in the list Do not use the software to access connect to control or manipulate any device or data without the full knowledge consent and authorization of the owner of such device or data Searching for another device If you need to connect to a different device simply tap the magnifying glass in the top left corner of the app and it will search for any devices in the area In order for you to connect to a patient s device they will need to tell you their 4 digit serial number located under the battery on the wristband You will be prompted to enter this after selecting the patient s device Authorize
32. me and icon Note A red symbol designating the assigned trigger opened Vee DaS ill tth 7 KJ a AJ wili appear at the 2 top right of the grip pattern s ae n amp A om N gt ron qwertyuiop asdfghjki gt zxcv bnm a After you tap Save this favorite will now be added to your list on the Favorites screen of the biosim app and can be activated in the future with a single tap ii ie r id 09 47 a V Favorites A2 Q ad o Connected to i limb access a vor A gt Home S Recreation Initial Setup Editing favorites Tap the edit button at the top right and the screen changes to look like the one seen below Here you can tap the red button to delete the favorite grab the handles and drag to change the order of the list and tap the name of the entry to edit the favorite Q Connected to limb access Connected to limb access a Work E Work fx f Home N a Home Ss Recreation 6 Recreation To edit any of your favorites simply go into the favorite you would like change Here you can modify the name icon grip pattern features and triggers i r 0248 b Edit Favorite Sl g favorite Work co Features When editing features you must return to the Edit Favorite screen above and tap save to confirm your changes Settings To access the Settings menu tap the se
33. n Tap the button below when finished Continue Cancel Cancel It is recommended that you create my grips when It is recommended that you create my grips when your prosthesis has a fully charged battery your prosthesis has a fully charged battery Now apply a close signal to flex the fingers into the desired position as noted Tap Continue when finished Tap the Test my grip button to test the grip To change the configuration of your my grip tap the Start Over button 8 Of om my gnp setup my grip setup NAME OF MY GRIP NAME OF MY GRIP My grip 12 My grip 12 Tap the button below to test out the grip ap the save button to keep your ch It is recomme oe you Create my grips when your prosthesis has a fully charged battery Cancel It is recommended that you create my grips when your prosthesis has a fully charged battery You may also use the digit Thumb o sliders to fine tune your a n my grip Please note that bd com digit sliders will not appear on m after initial configuration Opened wss YOu will have to exit your s a my grip and access again oo to fine tune using digits Little o sliders Thumb rotation o To save the my grip configuration tap Save Configuring my grips using QR codes Users are able to instantly program a custom pre configured my grip by scanning quick response QR codes provided by Touch Bionics Further information and a free QR
34. nnecting to the app Doing so will inhibit hands ability to detect grip chips If you press home button during this process cycle power to the hand or attempt to full reconnect and then disconnect from the app to reset connection Favorites screen Here you can assign groups of grip patterns and triggers a single name to make them easily accessible with a single tap eB 0 13 59 Favorites Recreation Initial setup J D D Note To access the Favorites screen at any time simply tap the heart icon Tapping on the favorite will instantly activate those settings on your device and display a quick reminder of what grip patterns and triggers are included O b Reminder Features being activated Thumb precision pinch Y closed N Hold open Creating a new favorite Everyone has their own set of features and triggers that they prefer to use for different tasks To set up a group of features tap the Settings icon in the top right corner Favorites Connected to i limb ultra revolution vn A Home Recreation Initial setup On the Settings menu tap Features Grip patterns to access the full set of grips available for selection Exactly the same as biosim on your computer from this screen you can choose the features that you like to group together a a Oo i Settings Q Y 0 FEATURES Y Y y D F F V
35. o delete the favorite grab the handles and drag to change the order of the list and tap the name of the entry to edit the favorite KF 10 3 mE Favorites K Favorites Connected to i limb ultra Connected to i limb ultra B work E work A Home w A Home amp Recreation 6 Recreation Recreation v Recreation EHEN a D j To edit any of your favorites simply go into the favorite you would like change Here you can modify the name icon grip pattern features and triggers b Edit Favorite favorite Work on Features When editing features you must return to the Edit Favorite screen above and tap Save to confirm your changes Settings To access the Settings menu tap the settings icon on the top right of the Favorites page iii Favorites Connected to i limb ultra ay won A gt Home S Recreation Initial Setup Other features To access more features back on the Settings menu you can also select Features Other which will provide a new screen showing various options that can be turned On or Off and activated for further customization Settings Q g te PULSING VARI GRIP FEATURES ON Grip Patterns Use vari grip e OS Delay 0 50 seconds Real time graph of signals NATURAL HAND Use natural hand on Hand health check Delay Control Strategy
36. of such device or data Searching for another device If you need to connect to a different device simply tap the magnifying glass in the top left corner of the app and it will search for any devices in the area In order for you to connect to a patient s device they will need to tell you their 4 digit serial number located proximal to the base of the thumb on the connection plate If the patient has a flexion wrist the serial number will appear at the base of the thumb You will be prompted to enter this after selecting the patient s device Authorized use only Please enter the 4 digits of the device s serial number If the hand should fail to connect to the app due to loss of power proximity with the Android device or other reasons the following screen will appear The hand failed to connect please turn the hand off and back on before trying to connect again Search In this instance turn off the i limb ultra for 4 seconds then turn back on Tap the Search button to reconnect Favorites screen Here you can assign groups of grip patterns and triggers a single name to make them easily accessible with a single tap iii Favorites Connected to inb ultra von A Home S Recreation Initial Setup Note To access the Favorites screen at any time simply tap the heart icon Tapping on the favorite will instantly activate those settings on the device
37. om this screen you can choose the features that you would like to group together ie Settings Q bd w FEATURES Other Real time graph of signals Hand health check Control Strategy Dual site Differential GENERAL Language System default rel The second option Features has been configured to other for the device and cannot be changed Disregard this Assigning triggers Tapping on a grip pattern will bring up a menu that allows you to assign one of the four possible triggers for activating it You may also set detect time for Hold open and Co contraction as well as duration and period times for Double Impulse and Triple Impulse Hold open DETECT TIME SECONDS Co contraction i 2 seconds Triple impulse i f time that the open signal must full stall of the digits before the 5 activated coq L Cc L Trigger Impulse Duration milliseconds Standard precision pinch opened Hold open Y i Co contra i 300 milliseconds Vouble impulse Triple impulse 1 0 seconds Choose the tot multiple imp mount of time allowed to accomplish that will activate a trigger Once you have selected a group of grip patterns and triggers that you would like to be able to access as a single group of favorites tap on the icon in the top right of the Features screen A screen will appear that allows you to choose a na
38. ound at www touchbionics com downloads document library For health and safety information regarding your Android device please refer to the product literature from Android Other important points e Updates will be available through the Google Play Store Check back regularly to ensure you are using the latest version of the biosim mobile app Up touch biOoNnics North American Customers Tel 1 855 MY iLIMB 694 5462 International Customers Tel 44 1506 438 556 Email info touchbionics com For address details and further information please visit www touchbionics com Copyright 2015 Touch Bionics Inc and Touch Bionics Limited All rights reserved Part number MA01312 Issue No 1 March 2015
39. ount you provided prior to being able to connect o on b Signin Terms and Conditions TOUCH BIONICS Please use your Touch Care Portal login information to sign in END USER LICENSE AGREEMENT email addre This End User License Agreement this Agreement is by and between Touch EMAS Ltd on behalf of itself and its affiliates collectively Touch and you User and is effective as of the date you accept and agree to the terms set forth herein the Effective Date Register with Touch Care Portal BY CLICKING THE ACCEPT BOX INDICATING YOU HAVE READ AND AGREED TO THIS AGREEMENT YOU FULLY ACCEPT AND AGREE TO ALL OF THE PROVISIONS OF THIS AGREEMENT IF YOU DO NOT AGREE TO THESE PROVISIONS DO NOT CLICK ACCEPT CLICKING ACCEPT AND ACCESSING THE SOFTWARE ESTABLISHES A BINDING AGREEMENT BETWEEN YOU AND TOUCH ACCEPTANCE OF THIS AGREEMENT IS REQUIRED AS A CONDITION TO ACCESSING AND USING THE SOFTWARE Sign in Upon registering please review the Terms and Conditions Tap Accept to continue Firmware Update Touch Bionics always recommends that you download the latest firmware for your device If a firmware update is available you will be prompted with the following screen upon connection to biosim Firmware update A firmware update is available for your device Current version 2 5 0 48 New version 2 5 0 50 Description of changes general performance improvements Tap Apply to ini
40. r positions AUTO GRASP Finger positions can also be selected for natural hand and default values set for i limb skin active or i limb skin natural covers Finger positions PULSING VARI GRIP FINGER POSITIONS Thumb Use vari grip Open Close Index Delay 0 50 seconds NATURAL HAND Open Close Use natural hand Middle 30 Delay _ 30 seconds Open ose Ring Finger positions 30 AUTO GRa pe Close E o m Finger positions Ring Open Little Open Thumb rotation Open Close DEFAULTS Load defaults for active skin Load defaults for natural skin Hand health check Selecting hand health check from the Settings menu brings up the option to run a test on an i limb device to ensure that everything is running as it should Tapping Run health check will run through a series of checks and will alert Touch Bionics to contact you if anything requires attention on your patient s i limb device c oe tF t mE Settings Qa Y w FEATURES Grip Patterns Other saa ska wan Hand health check grip chip setup Control Strategy Dual site Differential GENERAL Al OH Hand health check Note You must be Checking power to the hand Passed a en coh aa connected to the Internet using Wi Fi or cellular to run a hand health check Checking digit function Passed Real time graph Selecting the Real
41. rip option to assign to the grip chip ou Q B Oi my grip O grip chip info name of grip chip oe 2 2 da grip chip My grip My gnp 2 My grip My grip 4 Find grip chip DOODO Not allocated p favorite 7 Not allocated My grip 9 My grip My gro My grip 12 my grip My grip 1 After selecting a my grip to assign tap Save when arriving back to the grip chip info screen The grip chip is now shown with its name assignment number and battery level a ee You can reassign a grip or favorite and rename the grip chip if desired at any time by repeating this same process You also have the ability to deactivate a single grip chip or all grip chips Upon accessing the grip chip setup a toggle switch will appear on the top menu bar which allows you to enable disable all grip chips A toggle switch will also appear next to each individual grip chip allowing you to enable disable it Disabling a grip chip will not erase any pre programmed settings Iou b grip chip setup grip chip Om Thumb 3 jaw chuck tripod closed 1 Warning The battery level of grip chip 6 is below 10 OK Note Low battery warning will appear any time the app is running and a chip within range is at or below 10 on battery Please change the battery according to instructions provided You must disconnect from the hand prior to using grip chips Upon successful programming of grip chips you wil
42. rst Over The presence of the signal A before signal B results in the hand opening The presence of the signal 8 before signal A results in the hand closing Both signals must fall below the configured threshold before hand operation changes Single site Alternating The presence of a signal over the defined threshold results in the hand opening The next presence of the signal over the defined threshold results in the hand closing Single site Voluntary Opening The presence of the EMG signal that exceeds the threshold setting results in the hand opening Any signal below the threshold or removal of the signal will result in the hand closing Single site Voluntary Closing The presence of the EMG signal that exceeds the threshold setting results in the hand closing Any signal below the threshold or removal of the signal will result in the hand opening Languages The default language setting is English Select Language to change the settings to the appropriate language Settings Q Ad w Real time graph of signals Language Hand health check System default grip chip setup English Control Strategy Fran ais Dual site Differential Deutsch GENERA nglish Espanol About Connected hand app T amp C s Touch Bionics on the web Find more information About The final option on the Settings menu is the About option Tapping this brings up a screen displaying information abou
43. s successfully captured FEATURES Grip Patterns Other Real time graph of signals Hand health check l 11 Control Strategy Input channel Dual site Differential sain m GENERAL ci ow Language Input channel 2 System default 4 To exit the graph simply turn the Android device back to a vertical position or tap Done Control strategy Control strategy is the method by which the i limb device responds to the input signals This option allows the clinician to switch how the device responds according to 5 options N 24 E o u Settings Control Strategy Q ad Loi Dual site Differential ngth of the ration If FEATURES Grip Patterns Dual site First Over The presence of the signal A before signal B results in the hand opening The presence of the signal B before signal A results in the hand closing Both signals must fall below the configured threshold before hand operation Other changes N Single site Alternating Real time graph of signals The presence of a signal over the defined threshold results in the hand opening The next presence of the signal over the defined threshold results in the hand closing Hand health check ontrol Strategy al site Differential GENERAL Single site Voluntary Opening The presence of the EMG signal that exceeds the threshold setting results in the hand nal below the threshold or ignal will result in the hand
44. t the patient s prosthesis and the application The unique security code will also be found here i Oo m Settings b About Q g o HAND INFORMATION Real time graph of signals Hand health check _ APP INFORMATION grip chip setup Control Strategy Dual site Differential GENERAL Language Terms and conditions English About Connected hand app T amp C s Touch Bionics on the web Find more information fo so Oo Se Tapping Sign out will end the session and require you to sign in again for your next session For easy access we recommend you remain signed in Standard Standard Thumb precision Thumb precision precision pinch precision pinch pinch opened pinch closed opened closed Standard 3jaw Standard 3 jaw Thumb 3 jaw Thumb 3 jaw chuck tripod chuck tripod chuck tripod chuck tripod opened closed opened closed Thumb park Thumb park Lateral grip Index point continuous quick touch ae i limb ultra bionics Connection After signing in you will be brought to the connec tion screen where you will tap the device to which you want to connect Ml N Connect Devices u0001 Tap a device above to connect You may need to turn the hand off and back on for it to appear in the list Do not use the software to access connect to control or manipulate any device or data without the full knowledge consent and authorization of the owner
45. tiate the update Tapping Cancel will dismiss this screen Tapping Apply will bring you to the app update warning screen Ensure you read and comply with all warnings Tap Continue with update to proceed b Fipmuvare update A attention A You have chosen to apply the update at this time please ensure that you Do NOT turn off the power switch on the hand Do NOT turn off the phone Do NOT turn off Bluetooth If the update process is interrupted in any way due to power failure or loss of communications the hand will lock up and must be returned to Touch Bionics for repair This update takes up to 10 minutes to complete Note Ensure that you are able to perform the update without interruption Loss of power or hand communication could result in your device locking which will require service by Touch Bionics Total update time may take up to 10 minutes After tapping Continue with update you will arrive at a final confirmation screen Tap Yes to continue f Saving screenshot Please do NOT turn the device off or move the device during the update Are you sure you want to SPRY the firmware update to this de After tapping Yes the update will begin You will see a variety of screens as the update progresses Update screens may vary depending on device updated Sending 230 of 1310 packets At the conclusion of the update you will be prompted to turn your device o
46. time that the open signal must ained beyond full stall of the digits before the hold open trigger is activated j Trigger Impulse Duration milliseconds Standard precision pinch opened Hold open A Co con 300 milliseconds Double impulse iple impulse e allowed for the d and back below pulse he maximum am 1 0 seconds Choose thet allowed to accomplish multiple imp Once you have selected a group of grip patterns and triggers that you would like to be able to access as a single group of favorites tap on the icon in the top right of the Features screen A screen will appear that allows you to choose a name and icon Note A red symbol designating the assigned trigger top right of the grip pattern s cD VODO O s Q AJ will appear at the Y og Saving screenshot Select Icon New Favorite ma favorite gdo custom 4 a sad Icon qwertyui op asdfghj kil gt zxexecevbrnm After you tap Save this favorite will now be added to your list on the Favorites screen of the biosim app and can be activated in the future with a single tap _ iil Favorites Q ad o Connected to i limb ultra a wor x Home Recreation Initial setup Editing favorites Tap the edit button at the top right and the screen changes to look like the one seen below Here you can tap the red button t
47. ttings icon on the top right of the Favorites page ii CFB id 09 47 Favorites Recreation Initial Setup Q custom Hand health check Selecting hand health check from the Settings menu brings up the option to run a test on your device to ensure that everything is running as it should Tapping Run health check will run through a series of checks and will alert Touch Bionics to contact you if anything requires attention on your patient s i limb device Settings FEATURES Grip Patterns Other Real time graph of signals Hand health check Control Strategy Dual site Differential GENERAL Language System default e Hand health check Checking power to the hand Passed Checking battery life Passed A Checking digit function Passed Note You must be connected to the Internet using Wi Fi or cellular to run a hand health check Real time graph Selecting the Real time graph of signals option from the Settings menu brings up a graph showing the patient s input signals on the screen This visual information can be helpful when trying to activate certain triggers or work on controlling activation and relaxation of signals Turn the Android device horizontally to view the graph Tap the graph to adjust the gain and threshold settings You can save an image of the Real time Graph by tapping the camera on the top right of the scre