1. Do not use phenolic based products for cleaning Dry the mattress on a SUNLESS capitalised area after cleaning During cleaning procedures suitable protective clothing should be worn Ensure that the mains power supply to the pump has been disconnected prior to cleaning Follow the national requirements for the correct disposal of the pump unit 1 To store the mattress lay the mattress out flat and upside down 2 Roll from the head end towards the foot end A NOTE 7 Maintenance Do not fold crease or stack the mattresses Avoid direct sunlight The entire timer assembly should be replaced every 3 years of service If a fault occurs please refer to troubleshooting or contact Park House Healthcare Elite User Manual 8 Troubleshooting The pump is showing no indication it is working Check if the plug is connected to the mains Check that the hoses are all connected Check if there is any leakage in the mattress system Check that the CPR tag is still in place The low pressure light is constantly on Disconnect hoses from pump and check if air is coming out G Check that all hoses are connected securely Check that the CPR is in place The pump is on but not Check that there are no obvious leaks in the mattress inflating the mattress system Check that the pressure is in the suggested range for the weight of the patient Check that there are no kinks in the tu
2. Park House Healthcare ELITE PA5550 Mattress Replacement System User Manual CONTENTS On Introduction 1 1 General Information 1 2 Intended Use Product Description Installation 3 1 Unpacking 3 2 Setting Up Operation 4 1 Transport Mode 4 2 CPR Requirement 4 3 Support Setting Procedure Cleaning 5 1 Pump Unit 5 2 Mattress Storage Maintenance Troubleshooting Technical Description Guarantees and Warranty 10 1 Pump Unit 10 2 Mattress 10 3 Guarantee 10 4 Warranty 10 5 Claims relating to Guarantee and Warranty O O NN IMPORTANT SAFEGUARDS READ ALL INSTRUCTIONS BEFORE USING DANGER To reduce risk of electrocution Always unplug this product immediately after using Do not use while bathing Do not place or store product where it can fall or be pulled into a tub or sink Do not place in or drop into water or other liquid Do not reach for a product that has fallen into water Unplug immediately MeO Na WARNING To reduce risk of burns electrocution fire or injury to persons This product should never be left unattended when plugged in Close supervision is necessary when this product is used on or near children Use this product only for its intended use as described in this manual Do not use attachments not recommended by the manufacturer 4 Never operate this product if it has a damaged cord or plug if it is not working properly if it has been dropped
3. declination and provide the customer with an estimate on either the repair or replacement cost Park House Healthcare reserves the right to alter or amend this document without prior notice Elite User Manual Notes New Corporate Headquarters opened in October 2006 The Company Founded in 1984 Park House Healthcare Ltd is recognised as one of the leading manufacturers of specialist pressure relieving and pressure reducing equipment in the U K Park House Healthcare Ltd has an extensive product portfolio and the facility to customise products to suit customer needs whilst offering solutions in pressure care postural management and moving and handling Employing over 100 full time staff at our 60 000 sq ft state of the art Corporate Headquarters in West Yorkshire Park House Healthcare are proud to offer in house manufacturing a full product audit and decontamination service and a network of distribution centres as part of our continued commitment to Customer Care 24 hour care 365 days a year dedicated internal personnel manage specific regions and divisions ensuring one on one personal customer service at all times With distributors in over 25 countries Park House Healthcare are a truly international company and we place important emphasis on providing high levels of customer care to ensure we exceed customer expectations at all times Additional support nationwid
4. I Equipment E bt BI SAVE THIS MANUAL FOR REFERENCE 1 Introduction This manual should be used for initial setup of the system and for reference purposes 1 1 General Information The Elite is an alternating mattress replacement system suitable for the treatment and prevention of pressure ulcers 1 2 Intended Use This product is intended to reduce the incidence of pressure ulcers whilst optimising patient comfort A NOTE Equipment not suitable for use in the presence of a flammable anaesthetic mixture with air oxygen or nitrous oxide 2 Product Description The Elite Mattress Replacement System provides a cost effective solution for both the prevention and treatment of pressure ulcers suitable for patients up to Very High Risk Easy to install and operate the Elite is suitable for both hospital and homecare environments The Elite offers a comfortable support surface whose cells gently inflate and deflate in accordance with established alternating procedures With an underlayer of fully encased visco elastic foam for added support the Elite mattress combines alternating therapy with optimum user comfort 3 Installation 3 1 Unpacking The pump unit and mattress are packaged in separate boxes to secure the contents inside When unpacking the boxes to remove the pump unit and mattress check for any damage which may have occurred during shipping Please report any damages to Park House Healthcare and remove
5. bing running down the side of the mattress The system does not appear Check that there are no kinks in the tubing running to be alternating down the side of the mattress The pump is operating noisily Make sure the pump is resting against a solid surface If your problem cannot be resolved using the above information please contact Park House Healthcare WE Flite User Manual 9 Technical Description PA5550 Product Code Specification Power Supply refer to rating label on the product AC 230V 50Hz Fuse Rating T1A Dimension L x W x H 30 x 19 x 9 5 cm Weight 2kg Environment Temperature Operation 40 C to 70 C Storage 40 C to 70 C Shipping 40 C to 70 C 10 to 100 non condensing 10 to 100 non condensing 10 to 100 non condensing Humidity Operation Storage Shipping Class II Classification Mattress Specification Dimension L x W x H Weight 200 x 89 x 17 5 cm 3kg 30 80 mmHg 159 kg or 25 stones Pressure Range Maximum Patient Weight Contact the distributor or EU representative for further technical documents A NOTE 1 The specifications also apply to those areas operating with the same power supply 2 The manufacturer reserves the right to modify the specification without notice 3 The earth terminal is functional earth not a prot
6. deflation of the mattress is required disconnect the two hoses from the pump Elite User Manual 4 3 Support Setting Procedure It is important to follow the correct support setting procedure so to ensure the patient recieves adequate support maximum pressure relief and comfort Failure to do this could result in the patient being put at risk 1 Lie the patient on the mattress 2 Reset the pressure dial on the pump according to the patient s weight Ensure the correct pressure setting has been selected Yellow weight settings indicate where to position the dial if the patient is lying down white weight settings indicate where to position the dial if the patient is sitting up NB for pump models without weights indicated on the dial use the weight guide table below 3 Maximum patient weight limit 159kgs 350lbs 25 stones Minimum patient weight limit 31kgs 7Olbs 5 stones For patients weighing 31 kgs to 60 kgs set turn the pressure dial to 60 kgs or below Pressure Range Dial Weight kg Weight Ib Weight st amp Ib Soft 31 50 kg 70 110 Ib 5 st 7 st 12 Ib Tree eta 51 75 kg 112 165 Ib 8 st 11 st 11 Ib ai Sa 76 100 kg 168 220lb 12st 15st10lb Firm 100 159 kg 220 350lb 15 st10 lb 25 st NB The above is a guide only and the dial can be adjusted according to the individuals comfort requirements 5 Cleaning The following guidelines are suggested by Park House Healt
7. e is available through our service centres situation strategically around the country Park House Healthcare Ltd is a respected member of the British Healthcare Trade Association and has BS EN ISO 9001 and EN 46002 accreditation which is the specific quality standard for Medical Devices All products are CE marked in accordance with the European Directive 93 42 EEC ty ce Sj Registered Healthcare ISO Certificate No 8019 Park House Healthcare Ltd CE Certificate No CA001810 Whitehall 26 Business Park Master Indemnity Assurance No IFA 2433 0451 CCI 1 Heathfield Lane Birkenshaw West Yorkshire BD11 2HW UK Due to its policy of continued development and 0845 0600 333 improvement Park House Healthcare Ltd 0845 0600 334 reserves the right to amend any details sales parkhouse he com and specifications without notice 44 0 1274 475000 44 0 1274 475046 Copyright Park House Healthcare Ltd 2012 1 international parkhouse he com www parkhouse he com UM PA5550 15FEB2012 REV3
8. ective earth Elite User Manual D 10 Guarantees and Warranty 10 1 Pump Unit All new pumps have a guarantee for a period of 2 years following the date of dispatch 10 2 Mattress All new mattresses have a guarantee for a period of 2 years following the date of dispatch 10 3 Guarantee Park House Healthcare guarantees to repair or place any equipment issued to its customers which is found to be faulty during the relevant guarantee or warranty period The Company s guarantees are subject to following conditions a That the equipment has been used for the purpose for which it was intended b That the usage has been on a fair wear and tear basis c That the Company s cleaning disinfection guidelines have been followed d That the Company s maintenance guidelines have been followed e That maintenance has been carried out by a Park House approved engineer 10 4 Warranty Extended warranties can be purchased from Park House Healthcare for more information contact Customer Services on 0845 0600 333 10 5 Claims relating to Guarantee and Warranty In the event of a fault being discovered within the warranty period the customer must notify Park House Healthcare at the earliest opportunity If upon inspection Park House Healthcare accepts liability then the equipment shall be repaired or replaced immediately If Park House Healthcare does not accept liability it shall inform the customer of its reasons for
9. hcare Ltd as being suitable infection control procedures Further information is available upon request 5 1 Pump Unit It is important to follow the cleaning procedures for single patient use General cleaning may be affected by using a cloth dampened with a mild detergent and water solution This approach may be followed either by wiping with a sodium hypochlorite solution to a dilution of 1000 ppm or by using an alcoholic wipe Wipe the pump unit with a damp cloth and a mild detergent and keep it away from dust If another detergent is used choose one that will have no chemical effects on the surface of the plastic case of the pump unit A CAUTION Do not immerse or soak pump unit Do not use hyper carbonate or phenol based cleaning solutions Do not use any abrasive compounds or cleaning pads WS Flite User Manual 5 2 Mattress During general use the mattress and tube set may be cleaned by using a mild detergent solution Where appropriate mattress covers may be completely removed for laundering or sterilisation Whenever there is staining or body fluids on the mattress including the cells and tubing then a sodium hypochlorite solution to a dilution of 1000 ppm should be used following thorough cleansing with soap and water All mattress covers may be laundered as follows Pre Wash 80 C 15 minutes Main Wash 80 C 15 minutes Followed by cold rinses and extraction A CAUTION A CAUTION A CAUTION A CAUTION 6 Storage
10. or damaged or dropping in water return the product to a service centre for examination and repair oN 5 Keep the cord away from heated surfaces 6 Never block the air opening of this product or place it on a soft surface such as a bed or couch where their openings may be blocked Keep the air opening free of lint hair and other similar particles Ds Never drop or insert any object into any opening or hose 8 Connect this product to a properly grounded outlet only See grounding instructions NOTE CAUTION AND WARNING STATEMENTS NOTE Indicates some tips CAUTION Indicates correct operating or maintenance procedures in order to prevent damage to or destruction of the equipment or other property WARNING Calls attention to a potential danger that requires correct procedures or practices in order to prevent personal injury SYMBOLS BF symbol indicates this product is according to the degree or protecting against electric shock for type BF equipment Attention should read the instructions Grounding terminal for 230V system Disposal of Electrical amp Electronic Equipment WEEE This product should be handed over to an applicable collection point for the recycling of electrical and electronic equipment For more detailed information about recycling of this product please contact your local city office household waste disposal service or the retail store where you purchased this product Class I
11. the system from use Elite User Manual 3 2 Setting Up 1 Place the pump at the foot end of the bed 2 Remove the existing mattress and place the Elite system directly onto the bed frame with the cell or vapour cover uppermost The inflation tubes should be at the foot end of the bed A NOTE i The Elite pump must only be used with the Elite mattress or seat 3 Connect the tubes leading from the mattress to the outlet ports Inflation tubes should be at the foot end of the bed on the pump 4 Refer to the comfort control setting and adjust the dial according to the patient s weight see the patient weight guide section 4 3 5 Connect the pump to the mains power supply and switch on at the pump At this stage both the mains power and low pressure indicators will illuminate 6 Cover the support surface with a loosely fitting sheet 7 When the low pressure indicator has extinguished patient may be placed on the support surface and further bedding can be added 8 Test the low pressure alarm by pushing the button on the side of the pump and disconnecting the hoses 4 Operation A NOTE Always read the operating instructions before use 4 1 Transport Mode If required disconnect the hoses from the pump and join together The system will then equalise and retain mattress pressure once the pump has been shut off 4 2 CPR Requirement In the event of an emergency pull the CPR tag to deflate the mattress If rapid
Download Pdf Manuals
Related Search
Related Contents
Samsung NX3000 Hướng dẫn sử dụng "service manual" Wayne-Dalton 347610 Garage Door Opener User Manual TW - Wiener lab. KEY CUTTING MACHINE Operating manual IP Door Phone IP39-4x User`s Manual KN 6400-JLMS PSI Graphic Transport Framework User Manual Guia del Usuario Operación Access Copyright © All rights reserved.
Failed to retrieve file