Home

USER INSTRUCTIONS

image

Contents

1. attery Rechargeable reathing Tube 90 Deg Swivel reathing Tube 75 Deg Swivel reathing Tube Assy Responder 30 Lg reathing Tube Assy Responder 36 Lg reathing Tube Assy Loose Fitting Head Cover reathing Tube Assy White Loose Fitting Head Cover elt Assembly 60 Long elt Assy Decon 70 Lg X 2 W Drinking Bottle wValve utyl Hood M95 amp Promask Drinking Valve Kit Promask 2000 romask 2000 Head Harness NR hin Strap Butyl Hood hin Strap Loose Fitting Hood wiCape emote Cable Assembly reathing Tube Cover Tychem SL Airflow Indicator ABCFHIJLMNOPSLL ii ABCHJLMNOPSLL sacar IMA OV PH SD CS CN cE j P100 AM C D CL FM HC HF B4A 5036 HS MA OV PH SD CS CN sl HE AM CD CL FM HC HF H if a MA OV SD ABCFHIJLMNOPLL 23C 2458 P100 AM C D CL FM HC HF HS MA OV PH SD CS CN ABCHJLMNOPSLL 84A 5175 a F ee ee a S S M BE ee A E x B il ABCFHIJLMNOPSLL a ABCFHIJLMNOPLL HE AM CD CL FM HC HF H HE AM CD CL FM HC HF H HE AM CD CL FM HC HF H 1 Protection x x EEE ee ee eee ee ee ee E eee x x Bs ee es eee ee ee ee ee ee ee ee ee ee ee re ee ee E ee E ee re ee eee HE High Efficiency Particulate Air Filter For Powered Air purifying Respirators P100 Particulate Filter 99 97 filter efficiency level effective against all particulate aerosols AM Ammonia CD Chlorine Dioxide CL Chlorine FM Formaldehyde HC Hydrogen Chloride H
2. F Hydrogen Fluoride HS Hydrogen Sulfide MA Methylamine OV Organic Vapor PH Phosphine SD Sulfur Dioxide CS Chlorobenzylidene Malononitrile CN Chloroacetophenone 2 Cautions and Limitations A Not for use in atmospheres containing less than 19 5 oxygen B Not for use in atmospheres immediately dangerous to life or health C Do not exceed maximum use concentrations established by regulatory standards F Do not use respirator if airflow is less than 115 lpm 4CFM for tight fitting facepieces or 170 lpm 6CFM for hoods and or helmet H Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridges and canisters are replaced before breakthrough occurs l Contains electrical parts that may cause an ignition in flammable or explosive atmospheres J Failure to properly use and maintain this product could result in injury or death L Follow the manufacturer s User s Instructions for changing cartridges canisters and or filters M AIl approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to User s Instructions and or maintenance manuals for information on use and maintenance of these respirators P NIOSH does not evaluate respirators for use as surgical masks S Special or criti
3. Fluoride Hydrogen Sulfide and Sulfur Dioxide Formaldehyde Me thylamine and as a P100 Filter for an air purifying respirator APR The C420 PAPR System Promask 2000 facepiece M95 facepiece APRs and M96 cartridge have been tested at can ister levels for Tear Gas CS amp CN and Phosphine and can therefore be used as a gas mask for Tear Gas and Phosphine only Disposal These cartridges MUST be disposed of in strict accor dance with local state and or federal regulations A WARNING Failure to comply and follow the Disposal Storage Use Pre use or Duration instructions as outlined in these instructions may cause serious bodily injury or DEATH to oneself or others IMMEDIATE RESPONSE TECHNOLOGIES Manufacturer of TVI amp SafetyTech Products Immediate Response Technologies Inc P N C 85095 001 Rev 9 7100 Holladay Tyler Road Glenn Dale MD 20769 800 598 9711 This manual could contain technical inaccuracies or typographical errors Updates are made periodi cally to the information herein If you have comments please forward them to Immediate Response Technologies Inc Thank you N SERVICE anh Sy Sy IMMEDIATE RESPONSE TECHNOLOGIES INC atonal institute for 7100 HOLLADAY TYLER ROAD E A GLENN DALE MD 20769 D 800 598 9711 Immediate Response Technologies IRT M96 CARTRIDGE This Cartridge is approved only in the following configurations RESPIRATOR COMPONENTS CAUTIONS AND LIMI
4. TATIONS gis a HE AM CD CL FM HC HF H I TTT TT ALTERNATE FACEPIECE HEADCOVERS ALTERNATE BLOWER UNIT ALTERNATE AIRFLOW INDICATOR ALTERNATE POWER SOURCE ALTERNATE BREATHING TUBE ASSY ACCESSORY SPECTACLE FRAME ACCESSORY DRINKING BOTTLE ACCESSORY HYDRATION ACCESSORY HEAD HARNESS ACCESSORY FILTER CAP ACCESSORY CHIN STRAP ACCESSORY REMOTE CABLE ACCESSORY SPEAKING DIAPHRAGM REATHING TUBE COVER ACCESSORY HOOD ALTERNATE BELT ermobak Omega wi3L CBR 4 0 Res amp Type S GMA 5 Full Facepiece Regular 5 Full Facepiece Small 5 Speaking Diaphragm romask 2000 Full Facepiece Regular NR Harness oose Fitting Visor wiDrawstring QC CS Butyl Hood Assembly wilntegral Breathing Tube 5 Full Facepiece wiDrinking Device Regular 5 Full Facepiece wiDrinking Device Small oose Fitting Visor Head Cover Regular oose Fitting Visor Head Cover Regular Blue oose Fitting Visor Head Cover Regular Yellow oose Fitting Visor Head Cover Large Blue oose Fitting Visor Head Cover Large Yellow oose Fitting Hood wiCape Universal Tychem SL RT M96 Cartridge ARTRIDGE FILTER 5 Spectacle Frame 420 Blower Assy S Spd Toggle wiRemote Cable Con romask 2000 Full Facepiece romask 2000 Full Facepiece Small oose Fitting Hood wiCape Universal oose Fitting Visor Head Cover Large 420 Blower Assy Single Speed Toggle FlexAir Blower Assembly wiOnboard Battery Airflow Indicator 4 to6 CFM attery LiSO2 BAS800 U
5. USER INSTRUCTIONS FOR IMMEDIATE RESPONSE TECHNOLOGIES INC M96 CARTRIDGE PART NO S 70020 NSN 4240 01 574 9568 This cartridge shall only be used with NIOSH approved IMMEDIATE RESPONSE TECHNOLOGIES systems The NIOSH approval label see reverse outlines the NIOSH ap proved systems and their components that may be used with the M96 Cartridge Complete maintenance of systems and operating instructions are detailed in your system user manual The restrictions and limitations are outlined on the NIOSH approval label see reverse and must be followed strictly Failure to do so may cause severe bodily injury or death Pre Use Failure to change the cartridges when needed reduces the userG protection comfort and may cause severe bodily in jury or death Make sure 1 that the cartridge is appropriate for your application by checking with your Local Safety Program Administrator 2 verify that the packaging is intact and confirm the fol lowing that the cartridge part number on the wrap around label is S 70020 the word NIOSH is apparent the expira tion date date has not been passed 3 verify that the cartridge housing 1s not damaged Using damaged Cartridges may cause contamination to enter the system and cause serious bodily injury or death 4 verify that the filter seal for the Facepiece cartridge inlet or the rubber gasket for the Powered Air Blower Assembly cartridge port is in place and in good condition and in stall r
6. cal User s Instructions and or specific use limitations apply Refer to User s Instructions before donning LL This respirator contains filter or cartridge components that are not approved for all protections in all configurations Check the specific row on the NIOSH approval label to ensure proper use 01 10 by Immediate Response Technologies Glenn Dale Maryland All rights reserved
7. eplace if necessary 5 carefully thread the cartridge into the Facepiece or Pow ered Air Blower Assembly cartridge inlet until snug Duration The cartridge duration is determined by the atmosphere and contaminant in which it is being used Refer to your user s manual for specific details outlin ing the method of use and your actions However the user 1 must leave the contaminated area immediately if he she notices an increase in resistance or can detect Taste or Smell an odor The person must then follow the systemG user manual instructions for cartridge changeout 2 must change the cartridge if exposed to water Storage This cartridge shall be used as soon as possible after open ing However the M96 Cartridge has an extended storage life if stored unopened out of direct sunlight and in a dry environment Note the expiration date on the cartridge body S Special Use Limitations Apply The IRT M96 Cartridge when used with the C420 and FlexAir PAPR Systems meets NIOSH approval for organic vapors ammonia acid gases Chlorine Chlorine Dioxide Hydrogen Chloride Hydrogen Fluoride Hydrogen Sulfide and Sulfur Dioxide Formaldehyde Methylamine and as an HE Filter for powered air purifying respirator PAPR The M96 Cartridge when used with the Promask 2000 full facepiece and the M95 full facecepiece meets NIOSH ap proval for organic vapors ammonia acid gases Chlorine Chlorine Dioxide Hydrogen Chloride Hydrogen

Download Pdf Manuals