Home

er Datasheet

image

Contents

1. 2 years on design and manufacturing defects All specifications are subject to change Contact Sixnet to learn more EtherTRAK 2 Ethernet I O Module Specifications ORDER GUIDE PART NUMBER CICIEL DESCRIPTION E2 or EB MIX24880 D 32 channel combination I O with 1 isolated input counter E2 or EB MIX24882 D 24 8 8 2 34 channel combination O with 2 analog outputs E2 MIX20884 D 20 8 8 4 32 channel combination I O with 4 analog outputs and 4 isolated input counters E2 or EB 32D 24 D BZ 32 discrete inputs 10 30 VDC including 16 multifunction counters E2 or EB 16D 24 D 16 16 individually isolated discrete inputs 10 30 VDC with counters E2 16DIAC D 16 16 individually isolated discrete inputs 120 VAC nominal 10 30 VDC with counters E2 or EB 32D024 D 32 32 discrete outputs 10 30 VDC 0 5 Amp each 8 Amps total E2 or EB 16D024 D 16 16 individually isolated discrete ouputs 10 30VDC 1 Amp outputs 16 Amps total E2 16DORLY 16 16 individually isolated discrete outputs 1O 30VDC VAC relay 1 Amp outputs 16 Amps total E2 or EB 32AI20M D 32 32 analog inputs 4 20 mA with 16 bit accuracy E2 or EB 32Al10V D 32 32 analog inputs 0 10VDC E2 or EB 16AI20M D
2. 16 16 analog inputs 4 20 mA E2 or EB 8AO20M D 8 8 analog outputs 4 20 mA E2 or EB 16AI 8AO D 16 8 24 channel combination 16 analog inputs 4 20 mA and 8 analog outputs 4 20 mA E2 or EB 16ISOTC D 16TC 16 individually isolated analog inputs thermocouple and 250 mV with J K E R T C N S E2 or EB 16ISO20M D 16 16 individually isolated analgo inputs 4 20 mA E2 or EB 1IORTD D 1ORTD 10 analog inputs 100 Ohm platinum RTD rang is 200 to 850 C MECHANICAL DRAWING 3 49 88 77 5 25 133 231 0 25 ei j p o O24 6 22 iy i i MOUNTING OOA f N N HOLE UNDER Tapas eae oo g MODULE S S amo sili Gl 5 275 t69 781 gt 8 al ESen N N o u Sl S esh m gt S Sl se RIGH o E 5 49 139 57 Geel O18 Pet C_ 5 00 127 131 SIDE o 2 549 1139 57 z 8 ST ibe ii VIEW H J E 2 EIR S Sh se j Siis DIN RAIL DIN RAIL 8 8 ct I 1 4 nal Sl Bl 8 8 alo O 8 8 BE a Bl i b S18 see i E Lea E 006 11 593 gt R0 08 R216 IE ia DIN RAIL MOUNTING CLIP 110 27 94 3 14 130 68 3 00 76 33 Americas As the global experts in communication monitoring and control for a iT sales redlion net industrial automation and networking Red Lion has been delivering re rn i S innovative solutions for over forty years Our award winning Asia Pacific technology enables companies worldwide to gain real time data asia redlion net visibility that drives productiv
3. baud Protocols master and slave Sixnet and Modbus RTU ASCII Diagnostic LEDs transmit TD and receive RD Analog Output Channels Analog output range 4 20 mA D A resolution 16 bits less than 1 uA Full scale accuracy 0 02 at 20 C Span and offset temperature 50 ppm per C Load resistance 24 V 0 750 Ohms e Current limiting short circuit protection Refer to user manual for additional specifications Analog Input Channels Input range 4 20mA O 10VDC RTD thermocouple and 250mV A D resolution 16 bits 0 003 10 bits ImS fast option Input impedance resistance 100 ohms or 200 Kohms Fuses self resetting short circuit protection 4 20 mA inputs DMRR differential mode 66 db at 50 60 Hz Update time from 880 mS to 1 mS depending configuration Temperature accuracy typical uncalibrated 0 5 C RTD type 100 Ohm platinum RTD alpha 0 00385 or 0 00392 RTD connections 2 or 3 wire RTD input range 200 to 850 C Refer to user manual for additional specifications Discrete Input Channels Voltage range 10 30 VDC or 60 140 VAC Input isolation 150 volts 16 channel modules only Input resistance 10 Kohms Slow response software configurable 25 mS 20 Hz maximum counting rate Fastest response software configurable 1 mS 400 Hz maximum counting rate Special fast counting rate up to 50 KHz on channels 1 and 2 Count up pulse timing and pulse rat
4. AK 2 modules transcend simple I O capabilities to cost effectively streamline systems and improve reliability Control Center IPm IPm Controller Controller Service Ring Room Ring Switch Switch Real Time Ring EtherTRAK 2 EtherTRAK 2 1 O Modules 1 0 Modules wr Engine Room EtherTRAK 2 Ethernet I O Module Specifications INDUSTRIAL AUTOMATION Sixnet s rugged RT Us and O provide a simple yet powerful means to reliably monitor and control remote sites around the clock in the harshest environments Our compact automation systems can start small and grow as needs increase without requiring hardware replacement Virtually unlimited scalability means organizations have fewer restrictions on the number of remote sites or devices that are supported Best of both worlds programming combines Windows ease of use with the future proof security of an embedded Linux OS FEATURES amp BENEFITS High Performance Flexible I O Configuration Maintenance amp Monitoring e Provides high speed functionality e Delivers cross platform configuration e Lowers overall cost per I O point e Offers easy to use software tools Flexible mix of up to 34 I O supports Configuration and monitoring via standard DI DO Al AO temperature RTD and web browser thermocouples On board storage for project High resolution 16 bit analog or high speed documentation 10 bit analog Project based software t
5. Ether TRAK 2 Ethernet I O Modules Sixnet Automation Series red lon Ethernet I O Modules T o 3 a ke L 2 0 es Si PRODUCT HIGHLIGHTS Flexible mix of I O channels support all instrumentation needs Real Time Ring for fast redundancy Dual independent Ethernet ports enable flexible networking Built in security proactively blocks unwanted access Extensive health diagnostics and reporting reduce downtime Standard Modbus protocols provide universal compatibility Rugged design supports extreme temperatures and hazardous locations APPLICATIONS e Oil amp Gas Power amp Energy Transmission Distribution Transportation Mining e Maritime e Water Wastewater industri automation Sixnet s EtherTRAK 2 Ethernet I O modules provide a simple and secure way to reliably monitor remote sites located in harsh environments Offering the lowest cost per I O point and rugged environmental ratings Ether TRAK 2 modules are ideal for both control rooms and extreme locations across industries that include oil amp gas power amp energy transportation mining maritime and water wastewater Our compact DIN rail modules support open standard protocols to provide flexible communication options for existing or newly installed Ethernet networks By seamlessly replacing external devices such as switches data concentrators and protocol converters Ether TR
6. e 16 or 32 bit reporting Refer to user manual for additional specifications Discrete Output Channels Output voltage range 10 30 VDC or 10 30VDC AC Maximum output power up to 1A per channel Short circuit protection self reset fuses trip above 1 5 Amp Input isolation 150 volts 16 channel modules only All channels scan rate 1 mS Refer to user manual for additional specifications Web Interface Secure web access with password protection for multiple users 1simultaneous user 750K memory for user pages more with special order Environmental Operating temperature 40 to 75 C 40 to 85 C storage Humidity 5 to 95 RH non condensing optional conformal coating Flammability UL 94V 0 materials Vibration IEC60068 2 6 Shock IEC60068 2 27 Standards Compliance Electrical safety UL 508 CSA C22 2 142 EN61010 1 CE EMI emissions FCC part 15 ICES O03 Class A EN55022 IEC6100 6 4 CE EMC immunity IEC61000 6 2 EN61000 4 2 3 4 5 6 8 CE Hazardous locations Class 1 Div 2 Groups A B C D ISA12 12 01 CSA C22 2 213 ATEX Zone 2 IEC60079 0 15 e Marine and offshore tested and or verified to meet various standards such as ABS DNV No 2 4 and Lloyds Physical e Mounting DIN rail CEN50022 direct to panel or flat panel Packaging impact resistant Lexan polycarbonate Dimensions module and base 5 5 L x 3 5 W x 5 1 H 14cm x 8 9cm x 13cm Warranty
7. ity Product brands include Red Lion Europe N Tron and Sixnet With headquarters in York Pennsylvania the Middle East company has offices across the Americas Asia Pacific and Europe dli t Africa For more information please visit www redlion net Red Lion is a KURORT europe redlion net Spectris company Connect Monitor Control 1 717 767 6511 ADLDO181 122313 2013 Red Lion Controls
8. ools Fast I O polling of up to 1mS User based history tracks changes Advanced counter functions with 32 bit Per channel calibration reporting Configuration archiving Time proportioned outputs simplify high Module hot swap capabilities speed pulse rate functions Rugged Compact Design Built In Security e Supports harsh environments Prevents unwanted intrusion s Delivers proven reliability e Guards against unauthorized users Industrial 40 to 75 C operating range User assigned permissions UL CSA CUL FCC and CE rated Firewall protection Hazardous locations rated for Class Div 2 Zone 2 areas Flexible Redundant Networking Vibration resistant IEC60068 2 6 e Simplifies connectivity by replacing Ethernet Self resetting fuses protect I O switches noa e Ensures reliability without additional cost Watchdog Monitoring amp Reporting Real Time Ring switch mode for fast e Provides health reports of various module redundancy functions Switch elimination mode enables daisy s Reduces maintenance downtime chaining CPU health Dual independent Ethernet ports Dual power status Ethernet RS 485 and USB connections Communication activity Optional Power over Ethernet PoE PoE status Embedded data concentrator Port link status NETWORKING OPTIONS Break in Cable Active Data Path Real Time Ring Switch Mode Create redundant Ethernet reliability without additional cost Backup Data Path S
9. witch Elimination Mode Daisy chain modules without external switches to save money and simplify connectivity Two Networks Mode Each Ethernet port has a unique MAC and IP address for connection to two independent physical networks EtherTRAK 2 Ethernet I O Module Specifications SPECIFICATIONS General I O Performance Power supply voltage 10 30 VDC Input current requirement 100 mA 24 VDC typical with no loads PoE power EB modules only 10 watts at 60 C for user loads De rate up to 5 watts at 75 C O 512 discrete inputs and outputs plus 256 analog input and output registers Unique station addresses 16 000 Sixnet or 247 Modbus Ethernet Performance Ethernet ports 10 100Base Ix auto detecting Connection RJ45 auto crossover Isolation 1500 volts RMS 1 minute 60 Hz Message response time lt 1 mS per message Diagnostic LEDs solid indicates link blinking indicates activity Protocol support TCP IP ARP UDP ICMP DHCP HTTP Modbus UDP TCP slave mode Modbus UDP master mode Sixnet UDR UDP TCP slave mode Sixnet UDR UDP master mode Real Time Ring 5ms per hop recovery time Independent networks 1 or 2 with unique MAC and IP addres Serial Ports RS 485 port screw terminals 485 485 GND 2 wire half duplex not isolated RS 485 networking up to 32 full load stations RS 485 distance up to 0 5 miles baud rate dependent Baud rates from 300 to 57 600

Download Pdf Manuals

image

Related Search

Related Contents

User Manual - Snooper Services  Avaya 3100 Mobile Communicator Fundamentals User's Manual  Lunettes à vision nocturne Manuel d`utilisation  Essai d`élaboration d`une - Bibliothèques de l`Université de Lorraine  Manual Warrior Feed 304  IPM-02 - Austin Hughes  2012NB  Acer 1640 Personal Computer User Manual  Pastorino - Grandi Occasioni 2015  Preflight for Illustrator Manuel d`utilisation  