Home
Condition Monitoring - Southwest Seal and Supply
Contents
1. 1 87 NPT Testpoin 1 _ MEME 5 meter M12 8 pin plug and Deutsch 12 pin connector kit 016 RS232 to USB converter ACC6NNO17 12 long M12 8 way RS232 amp External Flow Device 019 M12 12 way cable 024 Cable Kit consists two 5 meter cables to enable all output options Communications cable and Relay Power Supply cable icountPDZ ATEX Approved Online Particle Detector For use explosive and hazardous areas The icountPD Particle Detector from Parker represents the most up to date technology in solid particle contamination analysis This compact permanently mounted laser based ATEX approved particle detector module is designed for use in Zone ll areas and is housed in a robust Stainless Steel IP69K approved enclsoure that provides a cost effective solution to fluid management and contamination control i inf ZONE TWO 1 AREAS Parker 2 22 oroma Gene Part Humber fee rt Number P24 44 10 1842 Fax 44 0 19427 E mail TOHM kum ae Oy Ni np Wen rio not separ e not remove Product Features e Independent monitoring of system contamination trends e Assembled in an
2. Bis e Flashing digit s code s that are above the set point limit The display for 504406 and NAS1638 are identical The ISO display is shown below E p diiit LE LIII P calibrated Measured ISO codes Moisture sensor reading Moisture sensor output settings The moisture sensor is an option that can be included when specifying the icountPD The moisture sensor reports on the saturation levels of the fluid passing through the icountPD sensing cell The output is a linear scale reporting within the range of 5 saturation to 100 saturation 9 15 5 4 8 25 8 9 05 125 50 12 1 50 2 50 75 16 2 25 3 75 100 20 3 00 5 00 icountPD Auxiliary Flow Device This simple to use flow control device fits on the downstream outlet side of the icountPD and is fitted with a differential pressure valve that adjusts the system flow to a range inside the icountPD specifications The flow control device will operate correctly between 150 psi 10 3 bar and 2900 psi 200 bar and the return back to an P N ACC6NNO19 open system of 0 psi 0 bar DP 2900 psi 200 bar T Meter Hose ACCeNNOOT X 2 Meter Hose Length X 5 Meter Hose Length ACCeNNoos _ accennoos x V4 BSPTestpom ACCenNoo7_ accennoos X Ve BSP Test point X
3. 6 000 PSI 420 bar rated maximum pressure Supported by the offline UBS and online SPS accessories icountLCM20 Features amp Benefits 2 minutes MTD 4 6 14 214 38 and 70 microns c 2 5 15 25 50 and 100 microns ISO 7 22 NAS 0 12 Memory access gives test search facility Test time Particle counts International codes Data retrieval Max working pressure 6000 psi 420 bar 106 GPM when used with system 20 Sensors Higher with single point sampler Max flow rate Working conditions LCM will operate with the system working normally Computer compatibility Interface via RS232 connection 9600 baud rate e Special diagnostics are incorporated into the icountLCM microprocessor control to ensure effective testing e Routine contamination monitoring of oil systems with icountLCM saves time and saves money e Contamination monitoring is now possible during applicaton operation icountLCM saves on production downtime Typical Applications e Construction machinery e Industrial plant e Hydraulic equipment amp system manufacturers e Research amp testing institutes e Offshore amp power generation e Marine e Military equipment applications Data entry allows individual equipment test log details to be recorded Data retrieval of test results from memory via hand set display Automatic test cycle logging of up to 300 tests can be selecte
4. Ambient temp 41 F to 104 F 5 C to 40 C 2 minute test completion time Memory store 300 test memory Battery operated 6 x 1 5 D cells Phosphate Ester group compatibility Mineral oil amp petroleum based fluid compatibility Up to 420 bar 6000 psi Integral 16 column printer RS232 to USB computer interface Astra board case weight Unit weight Ib 1 ParSmart software and cable link pack 15 14 6 17 6 Weather protector cover CE certified Auto logging Note In compliance with international standards all Parker portable particle counters can meet the ISO Medium test dust standards The icountL CM s in addition to the complete range of Condition Monitoring products are capable of achieving certification to ISO 4406 1999 and with traceability to ISO 11171 for SRM 2806 via ISO 11943 8 14 Va o dimensions inch mm Accessory Kit for icountLCM Classic Limit socket fuse ParSmart amp Power lead printer ribbon bar code pen amp weather cover Instruction manual amp bar code software Batteries amp printer reel Re chargeable battery pack icountLCM20 Portable Particle Counter Why On Site Fluid Contamination Monitoring e Certification of fluid cleanliness levels e Early warning instrument to he
5. D Cell batteries or rechargeable battery pack ACM20Z Rechargeable battery pack 12vDC input Printer facility Integral 16 column printer for hard copy data not available on icountACM20Z Certification Complies with all relevant EC declarations of conformity icount ACM20 Case Mounted Pump e Integrated Pump assembly incorporated onto the 20 unit e Powered directly from ACM20 unit LED power indication with no additional power supplies required e Direct sampling from fuel sample bottles or tank via 3 metre inlet suction tube e Incoporated double speed flush and test sequence e Managed flow rate correct volume sample as per IP 564 test method icountACM20 is fully compliant with the El Energy Institute test method Applications The Parker icountACM20 Portable Particle Counter has been developed from existing technology for monitoring contamination in Aviation Turbine and other hydrocarbon fuels in accordance with the Energy Institute El Method IP 564 In addition the ACM can also be used to monitor various fuels from existing sampling points in locations from refineries pipelines distribution terminals airport fuel supply systems all the way through to the point of uplift into aircraft Hot works permit required for online sampling ATEX Zone II unit available Fuel Testing Laboratories DEFSTAN 91 91 Issue 6 In order to better understand dispersed contamination in jet fuel particl
6. NAS classes based on maximum contamination limits particles per 100ml 00 125 22 1 0 0 250 44 8 2 0 1 500 89 16 1 2 1 000 178 32 6 1 3 2 000 356 63 11 2 4 4 000 712 126 22 4 5 8 000 1 425 253 45 8 6 16 000 2 850 506 90 16 7 32 000 5 700 1 012 180 32 8 64 000 11 400 2 025 360 64 9 128 000 22 800 4 050 20 128 10 256 000 45 600 8 100 1 440 256 11 512 000 91 000 16 200 2 980 512 12 1 024 000 182 400 32 400 5 760 1 024 SAE ASA059 rev E Table Note that this standard is technically identical to ISO 11218 MTD gt 4um c gt 6um c gt gt 14um c 21um c gt 38 gt 70 ACFTD gt 2um gt 5um gt 15um gt 25um gt 50um gt 100um Siecode FF 000 195 76 14 3 1 0 00 390 152 27 5 1 0 0 780 304 54 10 2 0 1 1 560 609 109 20 4 1 2 3 120 1 220 217 39 7 1 3 6 250 2 430 432 76 13 2 4 12 500 4 860 864 152 26 4 5 25 000 9 730 1 730 306 53 8 6 50 000 19 500 3 460 612 106 18 7 100 000 38 900 6 920 1 220 212 32 8 200 000 77 900 13 900 2 450 424 64 9 400 000 156 000 27 700 4 900 848 128 10 800 000 311 000 55 400 9 800 1 700 256 11 160 000 623 000 111 000 19 600 3 390 512 12 320 000 1 250 000 222 000 39 200 6 780 1 024 MTD ISO11171 Calibration or optical microscope count particle size based on projected area equivalent diameter ACFTD 504402 Calibration or optical microscope count particle size based on longest dimension GOST 17216 2001 Table The GOST standard is developed by the Technic
7. a lightweight compact and easy to use online sampling unit that connects icountLCM20 to a single pressure test point in a fluid system Suitable for use with mineral and biodegradable oils petroleum based and phosphate ester fluids the SPS offers fingertip operated control even at high pressures 6 000 PSI 420 bar rated maximum pressure S phosphate ester fluids Product Features Lightweight compact and easy to use online sampling unit e Connects icountLCM20 to a single pressure test point in a fluid system e Suitable for use with mineral and biodegradable oils petroleum based and phosphate ester fluids 6 000 PSI 420 bar rated maximum pressure Single Point Sampler Features amp Benefits The Single Point Sampler provides a means to connect an icountLCM20 to a single pressure test point and balance the differential pressure across the system to provide a controlled flow of oil into the icountLCM20 and away into a waste oil receptacle e Lightweight compact and easy to use design e Fingertip operated control valve even at high pressures e 6 000 PSI 420 bar rated e Facilitates testing from large diameter pipework e Capability to test up to 500cSt viscosity oils pressure permitting e Pressure compensated flow control mechanism e Possible to control the valve with the same level of accuracy whether the device is operating at high or low pressure e Capable of allowing a
8. RH non condensing 60 sec in slow moving air at 25 C 6 000 PSI 420 Bar 22 ft lbs Fluorocarbon EPDM Perfluoroelastomer Stainless Steel 303 M12x1 8 Way IP67 Connector IP68 when mated with molded cable 33 ft 10 m with Voltage Output 330 ft 100 m with current output SEE ORDERING INFORMATION 4 17 4 21 106 107mm 2 24 67mm 512 13mm M12 8 Way Connector 394 10mm Pin 2 Thread detail dice pattern M12 x 1 0 pitch 945 24mm Pin 1 A F Hexagon Pin Details 1 65 42mm dimensions in inch mm Pin Designations 1 White Alarm Switch 2 Brown Analogue 3 Green Alarm Limit 4 Yellow Analogue 5 Grey Receive 6 Pink Send Common 8 Red Supply Output Alarm Switch Constant 5Vdc when in normal operation owitch to OVdc when in alarm condition Hed LED illuminates when Sensor is in an alarm condition Output Temperature Deg Celsius User Select Output 0 3Vdc 0 5 1 6Vdc 4 20m4A Output Alarm Limit 0 6V Output that directly corresponds to the alarm set point Output Saturation User Select Output 0 3Vdc 0 5 1 6Vdc and 4 20m4 Input 85232 Communication Output RS232 Communication Input Common Ground from power supply Input Supply Voltage 8 to 30Vdc Green LED illuminates when power is properly applied 5300 Intrinsically Safe Specifications Pressure Outputs MAOP 6 0
9. and Instrumentation The Filtration Group consists of ten technical sales and service locations Finite Filter Hydraulic Filter Division North America Hydraulic Filter Division Europe two locations Process Filter Racor Parker Hannifin Brazil and Parker Hannifin Korea Customer Support Information Technical Support You Can Count On Parker s technical resources assure you of the right filtration technologies advanced designs consistent manufacturing and a network of helpful specialized professionals trained to support your team We listen to you then we design the right filtration solution Parker holds over 150 patents on innovative filtration products including filtration membranes differential pressure Indicators cartridge bypass valves and spin in elements Parker Filtration makes the technological investments needed to assure the highest quality products Examples are modern clean rooms sophisticated testing equipment CAD CAM engineering and CNC integrated equipment that is helping us design tomorrow s filtration products today Quality Is Top Priority Parker Filtration has had a total quality management system in place for years as well as a Director of Corporate Quality for all of Parker This structure helps us continually meet our customers expectations for the highest technical standards reliable supply and responsive service From the Group President on down Quality at Parker means more than making a
10. specifications furnished by Buyer to manufacture Product or d Buyer s failure to comply with these terms and conditions Seller shall not indemnify Buyer under any circumstance except as otherwise provided 13 Cancellations and Changes Orders shall not be subject to cancellation or change by Buyer for any reason except with Seller s written consent and upon terms that will indemnify defend and hold Seller harmless against all direct incidental and consequential loss or damage Seller may change product features specifications designs and availability with notice to Buyer 14 Limitation on Assignment Buyer may not assign its rights or obligations under this agreement without the prior written consent of Seller 15 Entire Agreement This agreement contains the entire agreement between the Buyer and Seller and constitutes the final complete and exclusive expression of the terms of the agreement All prior or contemporaneous written or oral agreements or negotiations with respect to the subject matter are herein merged Offer of Sale The items described in this document and other documents and descriptions provided by Parker Hannifin Corporation its subsidiaries and its authorized distributors Seller are hereby offered for sale at prices to be established by Seller This offer and its acceptance by any customer Buyer shall be governed by all of the following Terms and Conditions Buyer s order for any item described i
11. standard product selection Note 2 Alternate displayed part number selection will require you to contact Parker Filtration for availability ACC6NE015 B84702 Printer roll x 5 ACC6NE014 P 843702 Printer ribbon eaa __ AeessmyKterLEM Cass Note 1 Part numbers featured with bold highlighted codes will ensure a standard product selection Note 2 Alternate displayed part number selection will require you to contact Parker Filtration for availability ICOUNtACM 20 auni Aviation Fuel Contamination Monitoring DEFSTAN 91 91 Issue 6 Jet A 1Fuel Specification adopts particle counting The first fully functional particle counter approved for use on aviation fuel After 5 years of development work carried out by Parker UK and partner the ACM20 has passed all technical barriers and is now approved for aviation fuel quality per DEFSTAN 91 91 Issue 6 Parker has consistently provided technically superior products to all fluid conditioning applications Product Features icountACM20 monitors e Case mounted pump aviation fuel contamination enables monitoring to DEFSTAN 91 91 Issue 6 possibilities Jet A 1 fuel specification For example Fuel storage e Energy Institute Test vehicle tanks and fuel Method IP 564 storage drums 2 minute test procedure Latest averaging software Laser optical scanning as standard analysis e ParSmart Downloader Multi standard ISO cleanlin
12. 150 4406 19 Fiush Humbera Samples 1 Volume Sampie 10 ml Print P esults Don t Print Default Test Start Test Once the automatic oil sample test has been completed what next Solid contaminants in fluid power systems vary in size shape form and quantity The most harmful contaminants are normally between 6 microns and 14 microns The ISO code is the preferred method of reporting quantity of contaminants The ISO code number corresponds to contamination Analyzing the Test Results levels relating to three sizes The first scale number represents the number of particles that are equal to and greater than 4um c per ml of fluid the second number for particles that are equal to and greater than 6 um c per ml of fluid and the third number for particles that are equal to and greater than 14 um c per ml of fluid For example An ISO code 20 18 14 indicates that there are between 5 000 10 000 particles that are equal to and greater than 4um c between 1 300 2 500 particles that are equal to and greater than 6um c and between 80 160 particles that are equal to and greater than 14um c Principle of Operation Dimensions Weight Mechanical Composition Plastics Composition Environmental Operating Temperature Tested Operating RH Range Storage Temperature Storage RH Range Channel Sizes Analysis Range Contamination Stan
13. 2011 Parker Hannifin Corporation All Rights Reserved Content icountLCM20 Contamination 1 icountACM20 Lab Unit and 2024 7 Universal Bottle 13 52 Bottle 17 Single 29 System 20 Sensors and 26 icountPD and 31 COUMTO S A 41 Moisture Sensor 52 Oilcheck 2122 98 Guide to Contamination 61 Offer 69 Introduction Parker Hannifin is comprised of eight global groups Aerospace Climate amp Industrial Controls Fluid Connectors Seal Hydraulics Filtration Automation
14. Optional equipment needed High pressure is defined for this unit as more than 2 5 bar with a maximum of 350 bar We recommend that the IOS is positioned in a safe stable area as close as possible to the system output and only the hose fittings provided are used For pressure systems more than 2 5 bar one high pressure hose assemblies ACC6NNO034 and a Pressure Reducing Valve PRV 27 are required 350 bar pe Attach OUTLET 2 4mm hose To remove the PRV press down on the removal tool at the same time as lifting PRV off icountOS Features Proven Laser Detecton Technology The IOS uses light obscuration light blockage technology A light source is projected through a moving column of oil or fuel Contaminants in the fluid interrupt the light beam casting images on a photo diode cell where the resulting change in light intensity produces a directly proportional change in electrical output High Onboard Test Data Storage Capacity Class leading onboard memory provides storage capacity for up to 250 000 sets of test results Data is displayed instantly stored or downloaded to a PC or laptop for analysis via a standard IP68 RJ 45 patch cord connection a 2m cable is supplied as standard File types text CSV or 46 Quick Connection Connecting the IOS is quick and reliable The fluid connectors are on the front panel with two secure push fittings 236 diameter 6mm inlet and 157 dia
15. conditioning and industrial growth through premier customers worldwide customer service The Aerospace Group The Climate amp Industrial Con is a leader in the development f trols Group industrial and commercial sealing devices and related products by providing superior quality and total customer satisfaction markets rigid and flexible connectors and associated products used pneumatic and fluid systems esigns produces and esigns manufactures and markets a full spectrum markets quality filtration of hydraulic compnents and clarification products and systems to builders providing customers with and users of industrial the best value quality and mobile machinery technical support and and equipment global availability The Hydraulics Group The Filtration Group d E d The Automation Group The Instrumentation Group is is a leading supplier of a global leader in the design pneu matic and electro manufacture and distribution mechanical components of high quality critical flow and systems to automation components for worldwide customers worldwide processinstrumentation ultra high purity medical and analytical applications Worldwide Manufacturing Locations Parker Hannifin Corporation Filtration Group Global Headquarters 6035 Parkland Boulevard Cleveland OH 44124 4141 T 216 896 3000 F 216 896 4021 www parker com North America Compressed Air Tr
16. flow rate in excess of 10ml min when operating at any viscosity within the product specification Connection Instructions Single point icountLCM20 sampler icountLCM20 Only Carry out flow test as shown in the manual If test is showing below Dt 38 5 F 3 6 C then carry out test as normal If however test is above Dt 38 5 F 3 6 C then increase oil flow by turning valve A anticlockwise and then carry out flow test Do this until Dt is below 38 5 F 3 6 C and carry out test as normal once achieved WARNING Ensure that SPS valve is closed and icountLCM20 is connected to the SPS BEFORE connection to system ouitable for fluid temperatures from 5 C to 80 C 41 F to 176 F High quality polished finish stainless steel aircraft grade aluminium Capable of working with an icountLCM20 connected into a system via the standard metre extension hose kit Suitable for use with mineral and biodegradable oils petroleum based and phosphate ester fluids Phosphate ester version utilizes the 9 8 BSF HSP style fitting Designed so that it meets the lowest possible level of magnetic permeability oupplied with accessories kit It will maintain the set flow rate between upper and lower limits within a 100 bar inline pressure change Clear product identification to ensure that it is connected correctly i e downstream of the icountLCM20 Ensure valve is closed A Connect P2 on icount
17. have re configured the icountLCM specification in a way that has reduced our manufacturing costs These savings have been passed onto icountL Classic customers certificate How we done this nS 2 Parker listened to our existing customers and then the engineers and maintenance operatives to find out the features that make the icountLCM a unique predictive maintenance instrument Then we removed peripheral items such as the CD user guide MN aluminium case and all the accessories so a to house kit customer receives the icountLCM with a CD user guide professionally and securely boxed One thing that has not altered is the icountLCM accuracy and icountLCM reliability Our in house software engineers have re configured the EPROM removing Data programming User ID Automatic Testing Data retrieval Alarm level settings the barcode pen and Graph printing functions to reduce costs still further without in any way reducing the efficiency of the icountLCM The icountLCM Classic remains an instrument to be proud of Empty battery pack Ordering Information icountLCM and Classic icountLCM LCM2020 2 Hydraulic mineral icountLCM20 ACFTD calibrated 6 Skydrol 2 icountLCM20 MTD calibrated icountL CM20 classic ACFTD calibrated icount LCM20 classic MTD calibrated Note 1 Part numbers featured with bold highlighted codes will ensure a
18. product the right way Quality permeates our whole organization so that every employee thinks about what he or she does and what Is expected by our customers wt d E EE uu gt So 9001 ACCREDITED Always Available Customer Service Parker Filtration distributors provide local stock and technical design help including 24 hour emergency service They are further supported by our ever ready manufacturing teams So if you need more technical literature or applications Support please call us toll free at 1 800 253 1258 or at our 24 hour corporate help line at 1 800 C PARKER Parker Hannifin Corporation Hydraulic Filter Division 16810 Fulton County Road 2 Metamora OH 43540 Toll Free 800 253 1258 Phone 419 644 4311 Fax 419 644 6205 http www parker com hydraulicfilter icountLCM20 Fluid Condition Monitoring Portable Particle Counter A portable particle counter designed to be used in the field icountLCM20 is a proven answer to fluid system contamination monitoring Multi standard ISO and NAS cleanliness reporting data entry data graphing and integral printing are all standard on this world proven contamination monitor Product Features icountLCM20 is a proven answer to fluid system contamination monitoring 2 minute test procedure Multi standard ISO NAS and AS4059 cleanliness reporting Data entry data graphing and integral printer
19. psi 2 5Bar An optional inlet reduction valve is also available for high pressure applications Pressure Reducing Valve PRV A pressure compensated PRV device Parker Hannifin part number 27 has been developed to enable testing where flow pressures in the hose exceeds 35 psi 2 5 bar up to a maximum of 5000 psi 350 bar Hesults are viewed in the OLED digital display window High Pressure Connection Manual Connection Press the Pressure Reducing Valve firmly into the INLET port Low Pressure Connection Connect INLET 236 6mm hose Working pressure range to 35 psi 2 5 bar Working pressure with PRV 35 psi 2 5 to 5000 psi 350 bar Working viscosity 1 to 300 cSt icountOS Web Interface The IOS is a unique product in that it has tts own web page generator which means that the stored data can be downloaded or viewed on any PC or laptop Home Page Key Product description Key features Register the product at www parker com unlock Utilizing a computer s Internet Explorer utility simply plug in the supplied network cable open Explorer and enter the 05 unique IP MAC address icountO S Parker icount Oil Sampler utility application Parkers Condaion Manitonng looks beyond the customary solutions to approach in preventing system and componenl breaker comluned wath extending the thet of components in hyde are 6
20. systems Together with our customers we break new grounds to realize solutions for next generation systems Char pinces and intemal shudus based on dedazated markel beams priinachng to demanding makis customers and pariners maximum Economic and Ecological values The Parker Filtration Condition Monitoring IOS utility application is new tool developed by Hydraulic Filter Deasian Europe designed as an on line wel to setup change amd eontra ceram eustamer intertici options of the product The bool the sed up of counting nesull reporting slami s selechon data down load etc Some of the Key Features GMb Intemal Memory SO and MAS Code Reporting Instant Result Reporting Degital Display Weight Portable Product On Line Capability Fluid Direct LAN Connechon Capability PLEASE REGISTER THIS PRODUCT WITH YOUR LOCAL PARKER REPRESENTATIVE Data Log Page Key NA otart and Stop data logging Save data in one of three date formats XT format CSV Comma Separated Variables XML eXtended Markup Language Clear data logging memory List of the five last samples taken Memory usage icountOS Data Log Enables the icountOS data logging process Disables the icountOS data logging process Download and save all log data from the icountOS File format is Text Download and save log data from the icountOS File f
21. when it s on the truck it s yours Unless otherwise stated Seller may exercise its judgment in choosing the carrier and means of delivery No deferment of shipment at Buyers request beyond the respective dates indicated will be made except on terms that will indemnify defend and hold Seller harmless against all loss and additional expense Buyer shall be responsible for any additional shipping charges incurred by Seller due to Buyer s changes in shipping product specifications or in accordance with Section 13 herein 4 Warranty Seller warrants that the Products sold hereunder shall be free from defects in material or workmanship for a period of twelve months from the date of delivery to Buyer or 2 000 hours of normal use whichever occurs first The prices charged for Seller s products are based upon the exclusive limited warranty stated above and upon the following disclaimer DISCLAIMER OF WARRANTY THIS WARRANTY COMPRISES THE SOLE AND ENTIRE WARRANTY PERTAINING TO PRODUCTS PROVIDED HEREUNDER SELLER DISCLAIMS ALL OTHER WARRANTIES EXPRESS AND IMPLIED INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE 5 Claims Commencement of Actions Buyer shall promptly inspect all Products upon delivery No claims for shortages will be allowed unless reported to the Seller within 10 days of delivery No other claims against Seller will be allowed unless asserted in writing within 60 days after delivery or in the case of an
22. zero indication is given suitable for use with all mineral oils water and oil water Pressure Section emulsions The monitor has 3 dayglo dial gauges and Dial readings in both bar and psi up to 6 000 PSI 420 features a protective hinged cover bar Temperature section The temperature dial gives readings between 14 F to 230 F 10 C and 110 C Display Details Flow Section The flow scale has double scales for size 1 and 2 sensors only Calibrated up to 26 GPM 100 l min and Weight 100 GPM 380 l min The flow dial has excess flow 3 Ibs 1 4kg indication A viscosity chart is provided for mineral oil applications where monitoring is required at variable viscosities cSt Hose retainers System E pressure T gt E O S c 9 System ne Purge temperature 7 79 198mm ks Ordering Information dimensions in inch mm Standard products table STM 211110 STM G211 110 Oil Dual scale PSi bar Dual 8 6611110 STM 611 110 GPM DualscalePSl bar DualscaleF C _ Accessories ACCGNJOO0 P653607 ACC6NJ002 P653106 Metal sensor protective cap TED UMTER aerospace climate control filtration fluid amp gas handling hydraulics pneumatics process control sealing amp shielding icountPD Online Particle Detector ENGINEERING
23. 0 6 3 2007 icountPDZ Stainless Steel case construction icountPDZ Stainless Steel hydraulic block icountPD and icountPDH Viton seals icountPDZ fluorocarbon seals icountPD 7 2 x 6 1 x 3 4 182mm x 155mm x 86mm icountPDR 4 52 x 7 01 x 4 53 114 7mm c 178 8mm x 115mm icountPDZ 10 2 x 4 49 x 4 33 260mm x 114mm x 110mm icountPD 2 9 Ibs 1 3 kg icountPDZ 5 73 Ibs 2 6 kg See table on page 39 99 icountPD Dimensions Installation Details Communications Cable 1 9 49 cx Supply and Limit Relay Cable 0 6 16 ISO MTD x bo 6 c 2 4 CTRS 60 CTRS 0 8 21 2 0 52 6 1 155 dimensions in inch mm 4 3 110 7 2 182 2 mounting locations to suit M5 socket head cap screw Screw pack supplied with icountPD icountPD flange thickness 0 4 10mm Maximum Torque 5Nm Limit Relay Wiring Instructions NORMALLY OPEN NORMALLY CLOSED COMMON icountPD Variable mA Output Settings The following table can be used to equate the analog output for channels A B and C independently Example ISO code 12 is equal to 10mA mA 160 mA NAS 0040 0 MT 00
24. 00 PSI 420 bar 4 20mA current loop Operating temperature Calibration accuracy Minimum 40 F 40 C dependent on seal material 5 RH Maximum 185 85 C Compensated thermal stability Flow through sensor cell 1 RH 50 F to 176 F Installed in active flowstream Materials Fluid compatibility Stainless steel 303 Mineral oils petroleum based and Phosphate ester Sensor size weight Skydrol option available 4 21in x 01 97 0 66 Ib 107mm x e50mm 0 3Kg Viscosity range IP ratings Unlimited IP68 with specified molded cable Thread form connections See ordering information Developed in association with Triteq Ltd 4 17 4 21 106 107 mm 21 97 50mm 945 24mm 2 24 57mm 512 13mm 394 10mm IB 1157 Thread detail dice pattern 945 24mm M12 x 1 0 pitch A F Hexagon dimensions in inch mm 2 Moisture Sensor Connection Diagram H 1G S 1 Supply 4 20 mA Brown Ga ia T4 2 Signal 4 20 OUT White Sira 2255 3 is yi E Not Use Blac IECEx SIR 07 0089 opum Eos The MS300 has been certified as Intrinsically Safe Electrical Apparatus and offers fast reliable and accurate in line detection of moisture in fluids for use in hazardous areas ATEX Certification allows the MS300 into areas of a potentially explosive atmosphere that have previously not been allowed without permits it is intended for use in Zone 0 hazar
25. 059 NAS1638 particle count distributions Other calibration standards are included e On board compressor and shop air capable e Design concept allowing for portability DC and rechargeable battery pack options built in e Sample tube self cleaning sleeve minimizing cross contamination e 500 test sample memory e Data download via USB jump drive or USB to USB included e Internal printer Home Screen icount 10 ml Test Botte ID Bot 31 mi 40 m eil rmn ml 3r ml Number of Samples 100 ml crandard Flush yalumemersample 10ml Print Besulte Don t Print k 0 pe sat be ame fault ii au Sample Volume Test Parameters Bottle ID Bottle 007 Enter Battle ID Bottle 007 E 9 Sample ID Input Test Parameters Battle ID Bottle O07 Standlar cl 150 4406 1909 Flush mil 10 ml 15 20 ml per Sample 25 ml Pritt Mes 50 mi 100 ml Test Number of Samples Default me E LT E d B ha f I Flush Volume 19 Test Parameters Bottie ID Standard Flush Volume Mumber of Samples koume par Sample Results ber Test Number of Sample Runs ico 85 Test Parameters nettle ID Bottle 007 Standard
26. 20 0 2245 1 T 0 18 0 2050 2 NE T 1 16 0 3 EX 2 2 14 0 ec 4 a 3 8 12 0 5 4 10 0 6 5 E 6 60 8 7 2 40 85 9 M 8 2 0 EE TI 10 0004 9 1 2 3 4 5 6 7 8 I CODE 19 14 15 16 17 18 19 20 21 13 881 12 Eo 14 ii 16 2222 ERROR 20 A 17 Sata 18 18 19 9 ion 20 4 20mA output settings Si 21 ISO Setting 2 mA current ISO Code 2 4 10 it eg 10mA ISO 12 2 4 6 ERGO ii or 4 165 ISO Code mA current 4 2 2 eg ISO 12 10mA 4 2 00 1 2 3 4 5 6 7 8 9 10 11 12 13 NAS Setting NAS CODE mA current NAS Code 5 DES eg 15mA NAS 10 5 190 or OVERRANGE NAS Code mA current 5 20 0 ERROR eg NAS 10 15 5 Variable Voltage Output Settings The variable voltage output option has the capability of two different voltage ranges a 0 5 range as standard and a user selectable 0 3Vdc range The full list of commands on how to change the voltage output is available from Parker The following tables can be used to relate the analog output to an ISO or NAS code Table relating ISO codes to voltage output 0 5Vdc 0 3Vdc 0 2 0 7 lt 0 15 0 3 0 4 0 5 0 6 Or 0 8 0 1 0 For example 0 5 range ISO cod
27. Hose Sample Hose Inlet and Outlet Transfer Pump Housing Hose Tidy Clips Input Power Socket note that you will have to remove the plastic dust cap to access the 12Vdc power socket A fast blow 1 25A fuse and the RS232 connection are located behind the removable cover plate The RS232 interface is provided to download all test data stored in the instrument See the ParSmart Downloader software for more information icountACM20Z ATEX Approved Portable Particle Counter For use In explosive and hazardous areas icountACM20Z is designed to be used to monitor various fuels from existing sampling points in hazardous locations such as refineries pipelines distribution terminals airport fuel supply systems all the way through to the point of uplift into aircraft Product Features e Assembled in an approved and certified stainless steel enclosure to comply with ATEX Directive 94 9 EC e Can be used in explosive and hazardous areas including offshore and mining applications ATEX Zone Certified to CE Ex 1 3 G Ex nR nL T6 A Class product defined for the Aviation market ATEX approved Handset and keypad Suitable for use with mineral oil and petroleum based fluid as per ACM20 20 particle counters icountACM20Z Specifications Construction Unit Stainless Steel Carrying case ABS Hand held display ABS Keypad polyester membrane Mechanical components Br
28. LCM20 to P2 on Single Point Sampler SPS Connect drain line on SPS D Connect P1 of icountLCM20 to the system The SPS is ready to operate Open valve A slowly until the oil flows continuously from the drainline D into a reservoir or recepticale H Switch on monitor and begin testing Single Point Sampler Specifications Fluid Compatibility Mineral oil and petroleum based fluids Phosphate ester fluid For other fluids consult factory Seals Fluorocarbon or Perfluoroelastomer 4 84 123mm Maximum Working Pressure 6 000 PSI 420 bar Weight 500 grams max Not including hoses SWP 6 000 psi Unit Size i 1 77in dia x 4 8in long 45mm dia x 123mm long m System Connection 3 15 80mm Mineral petroleum fluids M16 G1 4 BSP with cap Phosphate ester 9 8 BSF HSP Operating Temperature Range 41 F to 176 F 5 C to 80 C Storage Temperature Range 15 F to 176 F 26 C to 80 C Construction Body Aluminium BS 1470 pressurized end stainless steel Finish Anodized blue Mineral fluid Anodized red Phosphate ester fluid dimensions in inch mm Ordering Information Standard products table SPS2021 Single point sampler mineral fuia _ sPs2061 SPS206 Single point sampler phosphate ester fluids Note 1 Part numbers in bold are standard product selection with all accessories System20 Inline Sensors amp Monito
29. S232 0 5 iPDR only RS232 CAN bus J1939 10 Deutsch DT Series iPD iPDR only 2 Yes 30 M12 8 pin plug connector iPD iPDZ only 40 M12 12 pin plug connector iPDR only Notes 1 When 3 is selected Box 2 1 must be selected in Box 7 Aviation Fuel option can also be used for diesel fluids For iPD and iPDR units when 5 is selected in Box 6 10 must be selected in Box 8 Contact Parker for additional communication options RS485 GPRS LAN WiFi Sat etc The required connecting cables are available as a kit The kit consists of two 5 meter cables Communications cable and Relay Power Supply cable to enable all output options See Accessory table on page 37 for applicable part number Notes aerospace climate control filtration fluid amp gas handling hydraulics pneumatics process control sealing amp shielding icount Oil Sampler 05 Portable Condition Monitoring for Hydraulic Oil and Fuel Systems ENGINEERING YOUR SUCCESS 41 Accurate Condition Monitoring made Quick Simple and Cost Effective The icountOS IOS is an innovative solution to the challenge of measuring the quality of hydraulic oils and hydrocarbon fuels in many different applications from renewable energy marine and offshore to manufacturing mobile agriculture military and aerospace Compact ligh
30. V Display Cut out size Power ouput a Alternative Indicator Weight Fixing Panel cutout mm 93x45 0 5 93x45 0 5 Push fit panel thickness 0 9mm to 3 2mm Dimensions mm 48x96x93 48x96x93 Sealing Designed to IP50 standard Front face may be silicon sealed after LED configuration Scale Supplied O to 10096 in horizontal Other scales in volume consult Parker Hannifin Scaling factors 1096 to 10096 range Fully adjustable Lamp intensity 4mcd each PBG8341A Front viewing Polarized Weight 29gms DDU1001 DDU1002 Product accessories part numbers DDU1001 P 9732PVC 10 Digital display unit 22 55 Vdc DDU1002 9732 05 Digital display unit 110 240 PBG8341A PBG 8341 1A Bar Graph Indicator 11 to 30 PAM8342 PAM 8342 Bar Graph alarm module 97200 5 meter M12 8 pin molded cable IP68 973200 M12 5 pin rewireable connector IP65 2 5970410 10 meter extension box ACCGNEOO08 S970400 UK 12 volt power supply S970400 European 12 volt power supply ACC6NE010 S970400 US 12 volt power supply 5 meter M12 5 pin molded cable 68 Moisture sensor output setting The Moisture sensor reports on the saturation levels of the fluid passing through the sensing cell The output a linear scale reporting within the range of 5 saturation to 100 satu
31. YOUR SUCCESS 31 icountPD The icountPD from Parker represents the most up to date technology in solid particle detection The design dynamics attention to detail and small size of the permanently mounted on line particle detector brings a truly innovative product to all industry The laser based leading edge technology is a cost effective market solution to fluid management and contamination control Typical Applications Mobile Equipment e Earth Moving Machinery e Harvesting e Forestry e Agriculture Industrial Equipment e Production Plants e Fluid Transfers e Pulp amp Paper e Refineries 3 Versions Available Standard icountPD is designed for test stand flushing skids filter carts and other industrial applications icountPDR is designed for mobile equipment or any outside use other than hazardous environment icountPDZ is intended for applications that require a Zone ll safety such as off shore platforms or any other hazardous environment For Zone applications the standard icountPD can be used within a NEMA7 enclosure icountPDR Power Generation e Wind Turbines e Gearboxes e Lubrication Systems Maintenance e Test Rigs e Flushing Stands Features and benefits of the icountPD include Independent monitoring of system contamination trends Early warning LED or digital display indicators for Low Medium and High contamination levels Moisture RH LED indic
32. aerospace climate control filtration fluid amp gas handling hydraulics pneumatics process control sealing amp shielding Condition Monitoring Products amp Custom Solutions ENGINEERING YOUR SUCCESS The Parker Hannifin Filtration Group assures B Consistent quality B Technical innovation B Premier customer service Parker s technical resources provide the right filtration technologies that conform to your requirements That s why thousands of manufacturers and equipment users around the world rely on Parker Filtration products and people Worldwide Sales and Service Parker operates sales and service centers in major industrial areas worldwide Call 1 800 C PARKER for more information and for a synopsis of our Filtration Technology Textbook Hydraulic Lubrication amp Coolant Filtration High performance filtration systems for production machinery in industrial mobile and military marine Compressed Air amp Gas Filtration Complete line of compressed air gas filtration products coalescing particulate and adsorption filters in many applications in many industries Process amp Chemical Fluid Filtration Liquid filtration systems for bever age chemical and food processing cosmetic paint water treatment photo processing and micro chip fabrication Fuel Conditioning amp Filtration Parker air fuel and oil filtration systems provide q
33. al Committee of Standardization TK 184 Ensuring Industrial Cleanliness introduced by the Government of Russia Adopted by the Inter governmental Committee of Standardization Metrology and Certification Protocol No 19 dated 24 May 2001 00 8 4 1 0 0 0 16 8 2 0 0 5 1 32 16 3 0 0 5 2 63 32 4 1 0 3 125 63 8 2 0 3 4 250 125 12 3 0 amp 5 500 250 25 4 1 2 6 1 000 500 50 6 2 7 2 000 1 000 100 12 4 3 8 4 000 2 000 200 25 6 9 9 8 000 4 000 400 50 12 5 10 16 000 8 000 800 100 25 11 31 500 16 000 1 600 200 50 5 12 63 000 31 500 3 150 400 100 13 63 000 6 300 800 200 14 3 125 000 12 500 1 600 400 15 25 000 3 150 800 16 50 000 6 300 1 600 17 E 125 000 3 150 NAV AIR 10 1A 17 Table The Navy Standard for Hydraulic Fluids used for aircraft hydraulic systems is defined in the Aviation Hydraulics Manual 1989 Table 2 1 Navy Standard for Particulate Cleanliness NAVY STANDARD FOR HYDRAULIC FLUIDS USED FOR AIRCRAFT HYDRAULIC SYSTEMS Particle Contamination Level by Class 1 2 3 4 5 6 Number of particles per 100ml 4 600 9 700 24 000 32 000 87 000 128 000 ESSO EIOS 12000 210 380 780 lO e So 0100 28 56 110 225 430 1000 3 5 11 gr 41 92 Particle size in um 5 10 10 25 25 50 50 100 gt 100 0 2 00 670 93 16 ISO NAS SAE Code Comparison Table The comparisons relate to particle count data only To conform to any particular standard referenc
34. ale display automatically calibrated for all sizes of System 20 Sensor Pressure Section Designed to indicate line pressure differential pressure and rising peak pressure Connected to a System 20 Sensor it will monitor pressure up to 6 000 PSI 420 bar with an accuracy of 1 FSD Hose retainers Ordering Information Standard products table Function keys Display Battery covers Temperature Section Temperature reading between 14 F to 230 F 10 C and 110 C Weight 3 Ibs 1 4kg Data Logging Each test logs the following data Test number time amp date sensor size media tested flow rate pressure amp temperature Data Download The System 20 electronic monitor is capable of downloading saved test data to a compatible PC via an RS232 connection using datum Batteries 6 x AA batteries Re calibration Annual certification by an approved Parker Service Center T Lr l a 39 4 1000mm nominal 00000 dimensions in inch mm EM209000 EM20 9000 System 20 electronic monitor P653607 6 001 85617 Not included with monitor Dongle and cable assembly System20 Analog Monitor Construction When the system is in reverse flow or when the high A sealed assembly requiring no routine maintenance pressure lines to the sensor have been transposed a or adjustment Body moulding in ABS The monitor is below
35. alleged breach of warranty within 30 days after the date within the warranty period on which the defect is or should have been discovered by Buyer Any action based upon breach of this agreement or upon any other claim arising out of this sale other than an action by Seller for any amount due to Seller from Buyer must be commenced within thirteen months from the date of tender of delivery by Seller or for a cause of action based upon an alleged breach of warranty within thirteen months from the date within the warranty period on which the defect is or should have been discovered by Buyer 6 LIMITATION OF LIABILITY UPON NOTIFICATION SELLER WILL AT ITS OPTION REPAIR OR REPLACE A DEFECTIVE PRODUCT OR REFUND THE PURCHASE PRICE IN NO EVENT SHALL SELLER BE LIABLE TO BUYER FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF OR AS THE RESULT OF THE SALE DELIVERY NON DELIVERY SERVICING USE OR LOSS OF USE OF THE PRODUCTS OR ANY PART THEREOF OR FOR ANY CHARGES OR EXPENSES OF ANY NATURE INCURRED WITHOUT SELLER S WRITTEN CONSENT EVEN IF SELLER HAS BEEN NEGLIGENT WHETHER IN CONTRACT TORT OR OTHER LEGAL THEORY IN NO EVENT SHALL SELLER S LIABILITY UNDER ANY CLAIM MADE BY BUYER EXCEED THE PURCHASE PRICE OF THE PRODUCTS 7 Contingencies Seller shall not be liable for any default or delay in performance if caused by circumstances beyond the reasonable control of Seller 8 User Responsibility The user throug
36. amages awarded in an action brought against Buyer based on an allegation that a Product sold pursuant to this Agreement infringes the Intellectual Property Rights of a third party Seller s obligation to defend and indemnify Buyer is contingent on Buyer notifying Seller within ten 10 days after Buyer becomes aware of such allegations of infringement and Seller having sole control over the defense of any allegations or actions including all negotiations for settlement or compromise If a Product is subject to a claim that it infringes the Intellectual Property Rights of a third party Seller may at its sole expense and option procure for Buyer the right to continue using the Product replace or modify the Product so as to make it noninfringing or offer to accept return of the Product and return the purchase price less a reasonable allowance for depreciation Notwithstanding the foregoing Seller shall have no liability for claims of infringement based on information provided by Buyer or directed to Products delivered hereunder for which the designs are specified in whole or part by Buyer or infringements resulting from the modification combination or use in a system of any Product sold hereunder The foregoing provisions of this Section shall constitute Seller s sole and exclusive liability and Buyer s sole and exclusive remedy for infringement of Intellectual Property Rights Parker Hannifin Corporation About Parker Hannifin Corporation P
37. approved and certified Stainless Steel enclosure to comply with ATEX Directive 94 9 EC e Can be used in explosive and hazardous areas e ATEX Zone ll Certified to CE Ex Il SGD Ex nA Gc Ex IIIC Dc SIRA O9ATEX4340X and IECEx SIR 09 0137 30 C lt Ta lt 60 C e Moisture amp 96RH indicator optional T Lo 4 arias 3GD Ex nA WC Ge Ex te MG De SECEx SIR 09 00 30 lt lt 60 A tete Do operating ireal connectors when energised cover in the hazardous area Warning limit relay outputs for low medium and high contamination levels Continuous performance for prolonged analysis Self diagnostic software Full PC PLC integration technology such as RS232 and O 5Volt 4 20mA CAN J1939 Contact Parker for other options Set up and Data logging support software included icountPD Ordering Information _ BOX1 BOX2 BOXS BOX6 BOX7 BOX8 IPD 1 2 2 2 2 1 30 IPD Standard Particle Detector IPDR Particle Detector Robust Construction IPDZ Particle Detector Hazardous Zone 2 1 Mineral Oil Phosphate Ester only Aviation Fuel 4 channel iPD iPDZ only 2 MTD 1 None iPDR iPDZ only LED iPD only Digital only Standard Default Settings for icountPDs Reporting interval Default if Options Fitted 1 iPDR only 2 Yes RS232 4 20mA R
38. arker s Charter Parker Hannifin is a leading global motion control To be a leading worldwide manufacturer of components company dedicated to delivering premier customer and systems for the builders and users of durable goods service A Fortune 500 corporation listed on the More specifically we will design market and manufacture New York Stock Exchange PH our components products controlling motion flow and pressure We will and systems comprise over 1 400 product lines that achieve profitable growth through premier customer service control motion in some 1 000 industrial and aerospace markets Parker is the only manufacturer to offer its Product Information customers a choice of hydraulic pneumatic and North American customers seeking product information the electromechanical motion control solutions Our location of a nearby distributor or repair services will receive Company has the largest distribution network its prompt attention by calling the Parker Product Information field with over 12 000 distributors serving our customers Center at our toll free number around the world 1 800 C PARKER 1 800 272 7537 In the UK a similar service is available by calling 0500 103 203 design manufacture and designs manufactures servicing of control systems markets system control and and components for aerospace fluid handling components and related high technology and systems to refrigeration markets while achieving air
39. arly warning of impending failure Oilcheck Features amp Benefits e comparator between new and used oils Oilcheck gives early warning of impending failure e Cost effective solution to save money and help improve system reliability e Completely portable battery powered e deal for reliability engineers and maintenance personnel e Numerical display to show positive or negative increase in dielectrics Typical Applications e Fleet Maintenance Garages e Construction equipment maintenance e Plant maintenance The Oilcheck from Parker detects and measures the dielectric constant of oil by comparing the measurements obtained from used and unused oils of the same brand Used as a regular service monitoring instrument the Oilcheck will give the user warning of fluid degredation and promote increased system component life Using Oilcheck Following the simple sampling procedure Parker s Oilcheck will ensure effective and highly repeatable results Once a clean oil sample has been placed in the Sensor Well and the TEST button has been pressed the instrument will zero on the sample Once cleaned out with a suitable solvent such as petroleum ether and replaced by a contaminated sample a new reading is obtained on the LCD which can be easily compared against the green amber red efficiency scale Oilcheck specifications Using Olicheck Case construction ABS The Oilchec
40. ass plated steel stainless steel and aluminium Seals Fluorocarbon Hoses Nylon Kevlar braided microbore Fluid compatibility All fuels For other fluids consult Parker Internal rechargeable battery Note ONLY to be charged outside of the hazardous area with the unit switched off Fuse 1 25A fast blow fuse included for overload protection Return to Parker Hannifin if fuse is blown icountACM202032 technology Unique optical scanning system Applications in Fuels e Oil Refinery To count and verify the levels of dispersed contamination in accordance with specification limits Consult Parker e Distribution Terminals Hubs Foruse on receipt and outbound supply Also to provide filtration performance tank cleanliness and product quality checks e Storage Settling times can be reduced by monitoring with the ACM by ensuring that levels of dispersed contamination are below acceptable levels e Airport Fuel Farm Monitoring of fuels into storage through the fuel farm hydrant system and during uplift into wing e Pipeline Commissioning Fastreal time monitoring of pipelines following pigging and cleaning processes e Oil and Gas Platforms Used to monitor the filtration performance system cleanliness and quality of delivered product icountACM20Z ATEX Approved Portable Particle Counter Installation Details 14 6 3 0mm 11 8 300mm dimensions in inch
41. ation domnick hunter Process Durham Road Birtley Co Durham DH3 2SF England T 44 0 191 410 5121 F 44 0 191 410 5312 www domnickhunter com Asia Pacific Australia 9 Carrington Road Castle Hill NSW 2154 Australia T 61 2 9634 777 F 61 2 9899 6184 www parker com australia China 280 YunQiao Road JinQiao Export Processing Zone Shanghai 101206 China T 86 21 5031 2525 F 86 21 5834 3714 www parker com china India Plot EL 26 MIDC TTC Industrial Area Mahape Navi Mumbai 400 709 India T 91 22 5613 7081 82 83 84 85 F 91 22 2768 6618 6841 www parker com india Japan 626 Totsuka cho Totsuka ku Yokohama shi 244 0003 Japan T 81 45 870 1522 F 81 45 864 5305 www parker com japan Korea 1 C Block Industrial Complex of Jangan 615 1 Geumui Ri Jangan Myeon Hwaseong City Gyeonggi Do Korea T 82 31 359 0771 F 82 31 359 0770 www parker com korea Singapore 11 Fourth Chin Bee Road Singapore 619 702 T 65 6887 6300 F 65 6261 4929 www parker com singapore Thailand 1023 3rd Floor TPS Building Pattanakam Road Suanluang Bangkok 10250 Thailand T 66 2717 8140 F 66 2717 8148 www parker com thailand Latin America Parker Comercio Ltda Filtration Division Estrada Municipal Joel de Paula 900 Eugenio de Melo Sao Jose dos Campos CEP 12225 390 SP Brazil T 55 12 4009 3500 F 55 12 4009 3529 www parker com br Pan American Division Miami 7400 NW 19th Street Suite A M
42. ation or light blockage Here a focused light source is projected through a moving column of oil in which the contaminants being measured are contained causing an image of the contaminant to be projected on to a photo diode cell changing light intensity to an electrical output The electrical output of the photo diode cell will vary in accordance with the size of the particles contained in the column of oil the larger the particle the bigger the change in the photo diode electrical output On line APCs must be able to test the oil sample at whatever cleanliness it is delivered to the machine Parker therefore had to develop technology to ensure the on line APC was able to test a sample without the conventional laboratory technique which requires dilution a practice that would have been simply impossible with a portable unit By careful design and window sizing 40 000 particles per ml can be achieved without making the instrument susceptible to counter saturation A focused light source is projected through a moving column of oil Laser Optical Sensing icountLCM Proven Core technology The icountLCM portable particle counter features microprocessor controlled optical scanning for accurate contaminant measurement with a calibration range from ISO 7 to ISO 22 with no counter saturation How does icountLCM work The particles are measured by a photo diode that converts light intensity to a voltage output which i
43. atment domnick hunter Industrial Dukesway Team Valley Trading Estate Gateshead Tyne amp Wear England NE11 OPZ T 44 0 191 402 9000 F 44 0 191 482 6296 www domnickhunter com Hiross Zander Padova Business Unit Strada Zona Industriale 4 35020 S Angelo di Piove Padova Italy T 39 049 9712 111 F 39 049 9701 911 www dh hiross com Hiross Zander Essen Business Unit Zander Aufbereitungstechnik GmbH Im Teelbruch 118 D 45219 Essen Germany T 49 2054 9340 F 49 2054 934164 www zander de Parker Gas Separations Oude Kerkstraat 4 P O Box 258 4870 AG Etten Leur Netherlands T 31 76 508 5300 F 31 76 508 5333 Engine Filtration amp Water Purification Racor Shaw Cross Business Park Churwell Vale Dewsbury WF12 7RD England T 44 0 1924 487000 F 44 0 1924 487038 www parker com rfde Racor Research amp Development Parker Hannifin GmbH amp Co KG Inselstrasse 3 5 70327 Stuttgart Germany T 49 0 711 7071 290 0 F 49 0 711 7071 290 70 www parker com racor Hydraulic Filtration Hydraulic Filter Stieltjesweg 8 6827 BV P O Box 5008 6802 EA Arnhem Holland T 31 26 3760376 F 31 26 3643620 www parker com eurofilt Urjala Operation Salmentie 260 31700 Urjala as Finland T 358 20 753 2500 F 358 20 753 2501 www parker com fi Condition Monitoring Center Brunel Way Thetford Norfolk IP 24 1HP England T 44 1842 763299 F 44 1842 756300 www parker com cmc Process Filtr
44. ator optional Cost effective solution in prolonging fluid life and reducing machine downtime Visual indicators with power and alarm output warnings Continuous performance for dependable analysis Hydraulic phosphate ester amp fuel fluid compatible construction Self diagnostic software Fully integrated PC PLC integration technology such as RS232 and 0 5 Volt 4 20mA and CANBUS J1939 icountPD icountPDR icountPDZ Diagnostic self check start up time Measurement period Reporting interval through RS232 Digital LED display update time Limit relay output 4 20mA output signal Principle of operation Reporting codes Calibration Calibration recommendation Performance Reproducibility Repeatability Power requirement Maximum current draw Hydraulic connection Flow range through the device Online flow range via System 20 Inline Sensors Required differential pressure across Inline Sensors Viscosity range Temperature icountPD and icountPDR Temperature icountPDZ Working pressure Moisture sensor calibration Operating humidity range Moisture sensor stability Certification Materials Dimensions Weight Default Settings 5 seconds 5 to 180 seconds to 3600 seconds Every second Changes occur 1 ISO code at set limit Hysteresis ON or customer set Hysteresis OFF Continuous Laser diode optical detection of actual particulates ISO 7 21 NAS 0 12 AS 00 12 contact Par
45. cture of the Products even if such apparatus has been specially converted or adapted for such manufacture and notwithstanding any charges paid by Buyer Unless otherwise agreed Seller shall have the right to alter discard or otherwise dispose of any special tooling or other property in its sole discretion at any time 11 Buyer s Obligation Rights of Seller To secure payment of all sums due or otherwise Seller shall retain a security interest in the goods delivered and this agreement shall be deemed a Security Agreement under the Uniform Commercial Code Buyer authorizes Seller as its attorney to execute and file on Buyer s behalf all documents Seller deems necessary to perfect its security interest Seller shall have a security interest in and lien upon any property of Buyer in Seller s possession as security for the payment of any amounts owed to Seller by Buyer 12 Improper use and Indemnity Buyer shall indemnify defend and hold Seller harmless from any claim liability damages lawsuits and costs including attorney fees whether for personal injury property damage patent trademark or copyright infringement or any other claim brought by or incurred by Buyer Buyer s employees or any other person arising out of a improper selection improper application or other misuse of Products purchased by Buyer from Seller 6 any act or omission negligent or otherwise of Buyer c Seller s use of patterns plans drawings or
46. d Efficient Offline Oil Sampling System Flow Rate Samples are best taken from a point in the system where the flow is TURBULENT Reynolds No greater than 4000 The turbulent flow creates a mixing action Where flow is streamline or LAMINAR larger particulate may tend to settle toward the lower pipe surface and not be sampled System Condition Changes Changes in the system operating condition flow temperature pressure or vibration can result in previously sedimented contaminant being retrained into the flowing oil It is also possible that these changes may cause partially contaminated filter elements to shed particulate into the system Samples should therefore be extracted when the system is in a steady state condition and the result less likely to be distorted by contaminant peaks There are a number of proprietary sampling valves available which adhere to good theoretical principles However they do tend to generate a level of precision and cost which is unnecessary for trend monitoring ACCG6NWAOO 1 50 ACCGNWOO2 ACC6NKO01 Sampling points should enable extraction of a sample without changing the system s condition Fine control needle valves are not desirable as they have a tendency to silt up under some operating conditions causing the distribution of contaminants in the fluid to be changed The sampling port should be protected to maintain cleanliness and thoroughly flushed before collecting the sample
47. d on a built in OLED digital display and can also be stored for subsequent upload via the embedded icount s web page interface connecting through an RJ45 cable 350 bar 2 0 bar max max input input pressure pressure to icountOS Optional icountOS 0 3 bak Check Valve 10 bar Check Valve Proven Laser Detection Technology Parker s experience in developing laser light obscuration or blockage and applying that technology in portable particle counting and detection is what makes Parker s range of contamination analyzers so very special Fig 1 In simple terms a controlled column of contaminated fluid enters the laser optical scanner chamber This design maintains contamination distribution within the fluid Fig 2 On reaching the photo diode cell the highly accurate laser light is applied and projected through that oil column The laser diode projects an image of the sample onto a photo diode cell Fig A cast image or shadow created by the contaminant in the oil creates a measurable change in the light intensity icountOS dimensions are in mm inches BOX OPEN 195 7 7 BOX CLOSED 9 8 11 8 Low Pressure Connection Setup We recommend that the IOS is positioned in a safe stable area as close as possible to the system output and only the hose fittings provided are used OUTLET Option 1 Option 2 OUTLET High Pressure Connection Setup
48. d via hand set display Totally portable can be used as easily in the field as in the laboratory Automatic calibration reminder Instant accurate results achieved with a 2 minute test cycle Data entry allows individual equipment footprint record Data graphing selectable via the integral printer Auto 300 test cycle logging via LCD handset input RS232 to USB computer interface Limit level output to control peripheral equipment such as off line filtration via internal relay limit switches Auto testing allows for the conducting of automatic sequencing tests on flushing systems for example Optional bar code swipe wand to allow handset data loading Worldwide service and technical support Re calibration Annual certification by an approved Parker Service Center icountLCM20 Specifications Automatic Particle Counters APC have been widely used for many years in condition monitoring of hydraulic fluids However it is only recently that APCs have become flexible enough to enable the instruments to be taken out of the laboratory and used on line in order to obtain the most credible form of results Unusually the move from fixed laboratory use to portable field use has not been at the expense of accuracy or user flexibility but has actually enabled the instruments to be used over a wider range of applications and situations The most common monitoring technique used in APCs is that of light obscur
49. dards Calibration Standard Fluid Management Possible Test Configurations Pre Test Flush Volume Viscosity Range Fluid Compatibility Sample Bottle Size Memory Storage Output Display Output Display Resolution Display Active Area Data Input Printer Printer Paper Test Certification Power Supply Battery Power Battery Stand By Time Battery Fuse Air Pressure Source icountBS Product Specification Laser based light obscuration H 20 9 x W 7 48 8 27 Door x D 16 1 31 Ib 14kg Stainless steel 316 plated mild steel and aluminum Precision polyurethane RIM moldings and ABS plastic 41 F to 140 F 5 C to 60 C 20 85 Tested at 86 F 80 C no condensation 40 F to 194 F 40 C to 90 C 10 90 Tested at 30 C no condensation MTD 4 gt gt 14 gt 21 gt 38 gt 70u c ACFTD gt 2u gt 5 gt 15 25y 50 100 ISO 7 to 21 NAS 0 to 12 MTD ISO 4406 1999 amp NAS 1638 ACFTD ISO 4406 1987 ISO 4406 1991 NAS 1638 and jAS4059E For further contamination standards consult Parker ISO MTD and ACFTD calibration to traceable ISO Standards Contact Parker for further details Maximum single sample 100ml Minimum single sample 10 User selectable from single test up to 5 tests per run eg 1 x 100ml up to 5 x 50ml per run Minimum 10ml Maximum 100ml 5 to 400 cSt Mineral oils petroleum and hydrocarbon based fluids F
50. dous areas requiring the use of category 1G equipment and has been designed for use with galvanic isolators to the specified values stated below The electrical parameters Ui 28V li 93mA 0 65 Ci 380nF Li O The following instructions apply to MS300 4 20mA Current Loop Moisture Sensor covered by certificate number Sira O7ATEX2255 1 The equipment may be located where flammable gases of Group may be present The equipment is only certified for use in ambient tempera tures in the range 4 F to 104 F 20 C to 40 C and should not be used outside this range 2 The equipment has not been assessed as safety related device as referred to by Directive 94 9 EC Annex clause 1 5 3 Installation of this equipment shall be carried out by suitably trained personnel in accordance with the applicable code of practice 4 Repair of this equipment shall be carried out by the manufacturer or in accordance with the applicable code of practice IEC 60079 19 Moisture Sensor Displays Specifications Bar Graph Indicator PBG83414 Construction Housing nylon 6 6 window acrylic bezel board supports ABS pins phosphor bronze Power supply Power supply 110 240 Vdc 11 30 Accuracy 0 196 typical 0 1 typical Signal input By dipswitch configuration Sample rate Off differential up to 5V Operating temp C A single signal Ref OV up to 5V Storage temp C single signal Ref 1V up to 6
51. e 16 is eaual to output of 3 5Vdc In a 0 3 range ISO code 8 is equal to an output of 1 0Vdc AES 11 2 1 3 0 5 0 3Vdc 2 1 4 1 5 1 6 lex 3 7 1 8 19 2 0 2i 2 2 2 3 24 8 2 4 22 45 Table relating NAS codes to voltage output 0 5Vdc 0 4 gt 4 6 0 3Vdc lt 02 N S 0 3 0 5 0 7 0 9 251 1 3 18 17 165 gt 2 8 Z 2 3 2 5 21 icountPD Display Parameters ISO 4406 NAS 1638 Digital display indication The digital display will show the The order of trigger for both of the actual measured codes the codes and moisture sensor option channel u size and the user 5 defineable limits Visible display of the channel size and user definable limits will alternate e Solid digit s code s that are at or below the set point limit The moisture sensor reading P 96 RH will also be shown if the moisture sensor option is fitted 4 A TIE Channel sizes limits Automatic light sensor LED display indication The LED display uses 3 sets of LED for the indication of ISO 4406 and NAS1638 code figures Individual code lights will trigger based on the customer settings The order of trigger will be e Solid green one ISO code or better below the set point limit e Blinking green ISO code at the set point limit e Solid red one ISO code above the set point limit e Blinking red two ISO codes or more above the set point limit
52. e counting is now included alongside existing laboratory techniques Bottle Sampling Energy Institute El IP 564 Laboratory determination of the level of dispersed contamination in aviation fuel using an Automatic Particle Counter APC Replace Clear amp Bright and Gravimetric With the introduction of the icount 20 all subjectivity surrounding Clear amp Bright and Gravimetric methods can be removed Also for use on petroleum based hydraulic applications Skydrol compatible available ouitable for use with mineral oil and petroleum based fluid as per standard hydraulic particle counter reporting fluid cleanliness to ISO 4406 1999 ICOUNtACM 20 auni Specifications Fuse 1 25 amp fast blow fuse includ Construction ABS structural foam and injection moulded case Hand held display ABS Keypad flurosilicone rubber icountACM20 Technology Mechanical Components Brass plated steel stainless steel and aluminium Repeatability Accuracy Seals Fluorocarbon Coincidence Hoses 40 000 particles per ml Nylon Kevlar braided microbore St steel armoured ends Viscosity Range 1 100 centistokes Flow Rate 25 28ml min dictated by CMP 100ml min with icountACM20 Weight additional flush button 17 6 1 5 Fluid Compatability Hydrocarbon Fuel Mineral Oil For other fluids consult Parker Monitor Carrying Case Astra Board case Carrying Case Weight 7 11 Ibs Ordering Information 5 Standard
53. e should be made to the recommended experimental procedure 13 11 08 2 14 12 09 3 0 15 13 10 4 1 16 14 09 400F 16 14 11 5 2 17 15 09 400 17 15 10 800F 17 15 12 6 3 18 16 10 800 18 16 11 1300F 18 16 13 T 4 19 17 11 1300 2000 19 17 14 8 3 20 18 12 2000 20 18 13 4400F 20 18 15 9 6 21 19 13 4400 6300F 21 19 16 10 22 20 13 6300 22 20 17 11 23 21 14 15 000 23 21 18 12 24 22 15 21 000 25 23 17 100 000 PPM Conversion Table _ Percent contamination vs PPM parts per million Percent PPM 100 1 000 000 10 100 000 1 10 000 0 1 1 000 0 01 100 0 001 10 Volume 1 litre 1 000ml 1 PPM Tul in 1 litre Example 1 400 PPM in 1 litre 400 ul Example 2 A reading of 250 PPM equates to a quantity of absorbed water a 400 litre capacity system of O 1 litre Offer of Sale The items described in this document and other documents and descriptions provided by Parker Hannifin Corporation its subsidiaries and its authorized distributors Seller are hereby offered for sale at prices to be established by Seller This offer and its acceptance by any customer Buyer shall be governed by all of the following Terms and Conditions Buyer s order for any item described in its document when communicated to Seller verbally or in writing shall constitute acceptance of this offer All goods or work described will be referred to as Products 1 Terms and Cond
54. eatment Filtration amp Separation Balston 242 Neck Road Haverhill MA 01835 0723 T 978 858 0505 F 978 858 0625 www parker com balston Filtration amp Separation Finite 500 Glaspie Street PO Box 599 Oxford MI 48371 5132 T 248 628 6400 F 248 628 1850 www parker com finitefilter Purification Dehydration and Filtration Division 4087 Walden Avenue Lancaster NY 14086 T 716 685 4040 F 716 685 1010 www airtek com Sales Office 5900 B Northwoods Parkway Charlotte NC 28269 T 704 921 9303 F 704 921 1960 www domnickhunter com Engine Filtration amp Water Purification Racor 3400 Finch Road PO Box 3208 Modesto CA 95353 T 209 521 7860 F 209 529 3278 www parker com racor Racor 850 North West St PO Box 6030 Holly Springs MS 38635 T 662 252 2656 F 662 274 2118 www parker com racor Racor 302 Parker Drive Beaufort SC 29906 T 843 846 3200 F 843 846 3230 www parker com racor Racor Village Marine Tec 2000 West 135th Street Gardena CA 90249 T 310 516 9911 F 310 538 3048 www villagemarine com Hydraulic Filtration Hydraulic Filter 16810 Fulton County Road 2 Metamora OH 43540 9714 T 419 644 4311 F 419 644 6205 www parker com hydraulicfilter Process Filtration Process Advanced Filtration 2340 Eastman Avenue Oxnard CA 93030 T 805 604 3400 F 805 604 3401 www parker com processfiltration 2011 Parker Hannifin Corporation Catalog 2300 ConMon Europe Compressed Air Tre
55. ess reporting icountACM20 icountACM20Z Features amp Benefits Test Time 2 minutes Repeat Test Time Every 2 minutes Manual testing every 6 minutes automatic Principle of Operation Optical scanning analysis and measurement of actual particles and inference to water presence Primary Output 24u c gt 6u c 214p c 221 225 230p c counts per ml Secondary Diagnostic Output Volume Distribution via graphical display on handset and printout printout not available on icountACM20Z International codes ISO 7 22 in accordance with ISO 4406 1999 Data entry 32 character two line dot matrix LCD Full alpha numeric entry facility on keypad Data retrieval Memory access gives test search facility for up to 300 saved tests Calibration In accordance with Parker Calibration Procedure CM20 N which complies to 15011171 1999 Clause 6 Omitting Annex F Re calibration Every 12 months by a dedicated Parker Service Centre Consult Parker as required under strict El methods Max working pressure 6 000 PSI 420 bar Operating Temperature 41 F to 176 F 5 to 80 C Memory store 300 test capacity Computer compatibility Interface via RS 232 connection 9600 baud rate USB serial cable to RS232 option available Laboratory sampling Utilizes on board rear mounted pump Portability Battery pack and carry case with wheels included Power requirement 20 12vDC input 6 x
56. f moisture in fluids The MS transducer type technology has been especially designed with the preventative maintenance programme environment in mind The industry accepted sensing cell device will monitor and report Relative Humidity RH moisture content in oils The water content measurement technique offers the end user benefits over the current standard form of water content reporting PPM This allows for real time preventative maintenance to be undertaken and corrective actions to be made By knowing that the water contamination is still within the oils absorbing range less than 10096 reclaiming fluid properties before additive damage occurs can initiate calculable cost savings 5200 Moisture Sensor Specifications Saturation Calibration Accuracy Temperature Calibration Accuracy Thermal Stability Stability Linearity Analog Output Hysteresis Switched Output Hysteresis Operating Temperature Range Operating Humidity Range Response Time Maximum Rated Pressure Maximum Torque Seal Material depending on MS Material Connector Details Maximum Cable Length Output Installation Details 21 97 50mm Moisture Sensor Wiring and 945 24mm EP _ 157 4mm t 3 RH 1 C 1 RH over compensated temperature range 10 to 80 C 0 2 RH typical at 50 RH in 1 year 0 5 RH typical 0 5 RH Full Scale 2 RH 40 F to 185 F 40 C to 85 C 5 to 100
57. for analysis Allow sufficient airspace in the bottle to enable 80 fill Bottle Cleanliness It is preferable that bottles have sealing screw caps and both parts are cleaned to a suitable level in accordance with 1503722 Standard Parker bottles are supplied clean to I8015 13 10 NAS Class 4 The bottle should remain capped until time of sample filling and re capped immediately afterwards Sample Mixing Sedimentation of contaminant in a sample will occur the rate of which is dependent upon both fluid and particle characteristics Samples should be analysed without delay once agitated and de gassed Universal Bottle Sampler Ordering Information Standard products table UBS9002 Universal bottle sampler includes aluminium case and accessories UBS9003 Universal bottle sampler UBS9004 Universal bottle sampler for phosphate ester fluids UBS9005 Universal bottle sampler Includes aluminium case and accessories Accessories Note 1 Part numbers featured with bold highlighted codes will ensure a standard product selection Note 2 Alternate displayed part number selection will require you to contact Parker Filtration for availability Typical Applications e Batch sampling e Aircraft rig certification e Oil research e Laboratory testing e Transfer line monitoring aerospace climate control electromechanical filtration fluid amp gas handling hydraulics pneumatics process control sealin
58. g amp shielding icountBS Bottle Sampler he benchtop solution to fluid contamination bottle sampling Darker ENGINEERING YOUR SUCCESS The Complete Solution Industrial Design Combined with State of the Art Technology The icountBS Bottle Sampler from Parker with its innovative industrial design has been developed for customers looking for state of the art technology attention to detail and the compactness of a permanent laboratory particle analysis instrument Combine this with on board laser based leading edge technology to bring to all industries a truly revolutionary Particle Counter The innovative icountBS is a product from the next generation of Parker s fluid particle analysis and monitoring solutions The IBS features an easy to use interactive touch screen environmentally controlled pressurized bottle chamber an internal compressor pump automated door locking mechanism sample tube cleaning sleeve that minimizes cross contamination and an internal printer The icountBS benefits from Parkers Knowledge and experience of providing fluid analysis equipment to the market for over 15 years icountBS Bottle Sampler Features amp Benefits e Customer programmable number of sample runs sample bottle averaging and pre test flush volumes from 10ml min to 100ml max e Input via fluid resistant touch screen display e Repeatable and reproducible performance to 1504406 1999 54
59. h its own analysis and testing is solely responsible for making the final selection of the system and Product and assuring that all performance endurance maintenance safety and warning requirements of the application are met The user must analyze all aspects of the application and follow applicable industry standards and Product information If Seller provides Product or system options the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the Products or systems 9 Loss to Buyer s Property Any designs tools patterns materials drawings confidential information or equipment furnished by Buyer or any other items which become Buyer s property may be considered obsolete and may be destroyed by Seller after two consecutive years have elapsed without Buyer placing an order for the items which are manufactured using such property Seller shall not be responsible for any loss or damage to such property while it is in Seller s possession or control 10 Special Tooling A tooling charge may be imposed for any special tooling including without limitation dies fixtures molds and patterns acquired to manufacture Products Such special tooling shall be and remain Seller s property notwithstanding payment of any charges by Buyer In no event will Buyer acquire any interest in apparatus belonging to Seller which is utilized in the manufa
60. hydraulic oil straight Flow control valves pe from the manufacturer Cylinders Low pressure heavy industrial systems or applications where long life is not critical 19 17 14 General machinery and mobile systems Gear pumps motors Important Medium pressure medium capacity 18 16 13 World Wide Fuel Charter cleanliness standard for Valve and piston Very important diesel fuel delivered from the filling station nozzle pumps motors High quality reliable systems Directional and ressure control valves General machine requirements 17 15 12 Highly sophisticated systems and hydrostatic Proportional valves Critical transmissions 16 14 11 Performance servo and high Pressure long life Industrial servovalves Critical systems e g Aircraft machine tools etc 15 13 09 Silt sensitive control system with very high High performance Super critical reliability servovalves Laboratory or aerospace NOTE The three figures of the ISO code numbers represent ISO level contamination grades for particles of gt 4um c 6um c and gt 14um c respectively NAS 1638 Table The NAS 1638 cleanliness standard was developed for aerospace components in the US and is still widely used for industrial and aerospace fluid power applications The figures are differential counts and the NAS class is usually reported as a single figure representing the maximum allowed particle counts i e worst case for designated particle size ranges 4
61. iami FL 33128 T 305 470 8800 F 305 470 8808 www parker com panam Africa Parker Hannifin Africa Pty Ltd Parker Place 10 Berne Avenue Aeroport Kempton Park 1620 South Africa T 27 11 9610700 F 27 11 3927213 www parker com eu
62. imit setting for Relative Humidity Conti 9 u ration Reporting Standard Set Report Standard Page Key amp 50 12 004106 1991 of 1904406 1575 Depending on the dust used t calibrate the 1035 NAS MAS 1638 1 Select either the ISO4406 1999 ae or NAS1638 standard 2 Confirm the selected standard IcountOS icountOS Specifications Product start up time Measurement period Reporting interval Principle of operation International codes range Calibration Recalibration and Servicing Working pressure Working viscosity Flow range through IOS Fluid connection interface Ambient storage temperature for unit Operating temperature for unit Operating humidity range Fluid operating temperature Oil Fluid operating temperature Fuel Moisture sensor Computer compatibility Power requirement Certification 10 seconds minimum Default 30 seconds run time 15 seconds data logging time Onboard data storage every second Output via RJ45 connection Laser diode optical detection of actual particulates Up to ISO 22 1 ISO code NAS 0 12 Calibration by recognized online methods confirmed by the relevant ISO procedures MTD via a certified primary ISO 11171 automatic particle detector using ISO 11943 principles Particle distribution reporting to ISO 4406 1999 Recommended every 12 months 35 5000 psi 2 5 350 bar Pressures above 35 psi require the use of a Parker Pressure Reducing Val
63. itions Seller s willingness to offer Products or accept an order for Products to or from Buyer is expressly conditioned on Buyer s assent to these Terms and Conditions and to the terms and conditions found on line at www parker com saleterms Seller objects to any contrary or additional term or condition of Buyer s order or any other document issued by Buyer 2 Price Adjustments Payments Prices stated on the reverse side or preceding pages of this document are valid for 30 days After 30 days Seller may change prices to reflect any increase in its costs resulting from state federal or local legislation price increases from its suppliers or any change in the rate charge or classification of any carrier The prices stated on the reverse or preceding pages of this document do not include any sales use or other taxes unless so stated specifically Unless otherwise specified by Seller all prices are F O B Seller s facility and payment is due 30 days from the date of invoice After 30 days Buyer shall pay interest on any unpaid invoices at the rate of 1 5 per month or the maximum allowable rate under applicable law 3 Delivery Dates Title and Risk Shipment All delivery dates are approximate and Seller shall not be responsible for any damages resulting from any delay Regardless of the manner of shipment title to any products and risk of loss or damage shall pass to Buyer upon tender to the carrier at Seller s facility i e
64. k can remove the need for Circuitry costly and time consuming laboratory Microprocessor control analysis of mineral and synthetic oils Battery used in hydraulics gear boxes bearing lubrication systems and engines It 1 x 9V alkaline Supplied detects wear debris and any loss of a 0 0 99 lubricating properties the oil Olicheck Suitable oil types The Oilcheck is able to show chan Green amber red ges Mineral and synthetic based oils aera the oil condition brought about by Repeatability the ingress of water content metallic Better than 5 content and fuel contamination Readout Green amber red grading Numerical value 0 10090 Battery lifetime gt 150 hours or 3 000 tests Dimensions 9 8 x 3 7 x 1 3 250mm x 95mm x 34mm Weight E unction 0 4kg buttons Installation Details 23 14 95mm Visual display Numerical display Sample sensor Re cal button N E eL 69 929 525666 Test 92 222020525520 button a 2709 o o Ds 559 8 oco 07070007070 On Off states 0 020 Hi Lo switch Sa o o Qd 0929 929 9 2 52 64mm 1 26 32mm 1 34 84mm Ordering Information dimensions in inch mm Standard products table OLK605 Oilcheck kit with numerical readout Note Petroleum ether can be used as a between sample cleaner Guide to Contamination Standa
65. ker Icount will also report less than ISO 7 subject to the statistical uncertainty defined 504406 1999 which is shown in the RS232 reporting results as appropriate e g gt 6 By recognized on line methods confirmed by the relevant International Standards Organization procedures 12 months 24 months for icountPDZ t 1 ISO Code dependant on stability of flow Better than 1 ISO Code Regulated 9 to 40Vdc 150mA icountPD M16 x 2 hydraulic test points 5 8 BSF for aggressive version icountPD Z2 Size 066 Connection EO 24 cone end 40 to 140 ml min optimum flow 60ml min Size 0 1 59 to 6 6 gpm optimum flow 3 96 gpm Size 1 6 34 to 26 4 gpm optimum flow 18 5 gpm Size 2 44 9 to 100 gpm optimum flow 66 gpm 5 8 psi 0 4 bar minimum 10 to 500 cSt 1 to 500 cSt Operating environment 4 F to 140 F 20 C to 60 C Storage 40 F to 176 F 40 C to 80 C Operating fluid 32 F to 185 F 0 C to 85 C Operating environment 22 F to 140 F 30 C to 60 C Storage 40 F to 176 F 40 C to 80 C Operating fluid 41 F to 176 F 5 C to 80 C 30 to 6 000 PSI 2 to 420 bar 5 RH over compensated temperature range of 10 C to 80 C 5 RH to 100 RH 0 2 RH typical at 50 RH in one year IP66 rated icountPD IP69K icountPDZ 61000 6 2 2001 PDR EN6100 6 2 2005 icountPDZ EN61000 6 3 2001 icountPD PDR EN6100
66. lp prevent catastrophic failure in critical systems e Immediate results with laboratory accuracy e o comply with customer cleanliness requirements and specifications e New equipment warranty compliance e New oil cleanliness testing Data Download Management Dedicated software provides the link between an EUR S icountLCM20 and your computer management system 16 column printer for hard copy data A feature of the icountLCM is the on board printout data graphing option developed to support predictive maintenance procedures icountLCM Test ON LINE TEST icountLCM Test TEST NUMBER 022 ON LINE TEST TEST NUMBER 022 ve 15 52 DMY Date 04 03 10 NAS CLASS 7 20 15 09 Count 100ml Count 100 4 789157 6 14u 31250 gt 4 820721 NAS CLASS 31564 14 21 C 250 214 314 NAS CLASS 3 gt 21 64 21 38 c 50 14 NAS CLASS 3 gt 70u 0 38 70u 14 NAS CLASS 4 NOTES Sou NAS CLASS 0 NOTES ISO 4406 1999 Correlation to NAS 1638 icountLCM20 Portable Particle Counter Introducing the new icountLCM Classic There is a new addition to the proven range the Classic icountLCM20 icountL CM Classic Only available from Parker the Classic retains all the technology that made the icountl CM one of the most accurate reliable and popular portable particle counters available Our design engineers
67. meter 4mm outlet drain Parker can supply dedicated hoses and fittings for use with most hydraulic and hydrocarbon fluids Tough Storm Case The robust waterproof 54 when open case and fully sealed impact resistant brushed stainless steel front panel provide excellent protection in the most demanding of applications The combined unit weighs under 12 1 Ib 5 5kg making it an ideal first use diagnostic service tool Fast Contamination Detection The IOS provides fast detection of the presence of contaminants with the results being shown on the front panel mounted high visibility OLED digital display This provides easy identification of fluid condition showing measured codes the sizes per channel in microns the user definable limits and moisture sensor readings as a 96 of relative humidity Complies with the Latest Standards The IOS is designed in accordance with the latest global standards including CEmarking e EMC EN61000 6 3 2001 e EC Declaration of Conformity EN61000 6 2 2001 e Machinery Directive e EN 61010 1 2001 Long Life Remote Operation The IOS uses a long life regulated 12 Vdc power supply with an M12 4 pin connector plus a rechargeable NiMH detector battery unit for use onsite or in remote locations Fluid and Pressure Control The IOS automatically adjusts flow rates to an optimum level of 60ml min Total flow range is between 40 and 140ml min with maximum online operating pressure being 36
68. mm Online Commission Kit a icountACM20 Zone Il Particle Counter b Battery Charger c Process Cable d User Manual e Downloader Software f Throttle Kit g Millipore Adaptor Assembly h Aluminium Case Bottle Assembly Universal Bottle Sampler simple and efficient offline oil sampling Ideal for batch oil sampling The UBS provides the dynamic link to portable particle counters The UBS off line sampler has microprocessor technology to recognize and adjust to the connecting monitor including the icountLCM20 Product Features e Simple operation e Efficient testing procedure e Clean and contamination free sampling e Available for both mineral based and aggressive fluids e Further advances the LCM20 s flexibility into laboratory bottle sampling environments e Can accept various different sized bottles e Minimal working parts e Internal auto setting fuse for overload protection e Simple maintenance procedures Universal Bottle Sampler Specifications T viscosity range 2tozoest X Operating temp 21 to 176F 90103800 Test time 2miss 4miss x viery approved operation CDegssngchamer CSampewbepak xo CimeracecabetoLOMgo X Installation Details 5 79 7 05 179mm 6 5 165mm 3 94 100mm CTRS dimensions in inch mm Universal Bottle Sampler simple an
69. n its document when communicated to Seller verbally or in writing shall constitute acceptance of this offer All goods or work described will be referred to as Products 16 Waiver and Severability Failure to enforce any provision of this agreement 20 Taxes Unless otherwise indicated all prices and charges are exclusive will not waive that provision nor will any such failure prejudice Seller s right of excise sales use property occupational or like taxes which may be to enforce that provision in the future Invalidation of any provision of this imposed by any taxing authority upon the manufacture sale or delivery of agreement by legislation or other rule of law shall not invalidate any other Products provision herein The remaining provisions of this agreement will remain in full force and effect 21 Equal Opportunity Clause For the performance of government contracts and where dollar value of the Products exceed 10 000 the equal 17 Termination This agreement may be terminated by Seller for any employment opportunity clauses in Executive Order 11246 VEVRAA and 41 reason and at any time by giving Buyer thirty 30 days written notice of C F R 88 60 1 4 60 741 5 a and 60 250 4 are hereby incorporated termination In addition Seller may by written notice immediately terminate this agreement for the following a Buyer commits a breach of any provision of this agreement b the appointment of a trustee receiver o
70. nd water oil emulsions Analog Monitor STM e Utilizes 3 Day Glo dial gauges with a protective hinged cover e Calibrated up to 100 gpm with dual scale PSI bar amp F C USGPM also available Electronic Monitor EM20 e Gives a full digital display e Automatically calibrated for all 3 sizes of sensor e Indicates line differential and rising peak pressure e Easily scrolled from metric to US e 300 test memory e Capable of downloading saved data to download software Industrial STI family Typical Applications e Drilling equipment e Mining e Grinding and conveying e Industrial hydraulics e Mobile applications 2 sizes of System20 Inline Mobile Sensors are available Hydraulic system users need to ensure that lost production is kept to the absolute minimum To ensure this predictive maintenance utilizing routine condition monitoring of hydraulic systems is essential System20 Specifications Sensors Construction Industrial STI Body 303 SS Internal components SS and Brass Mobile STS Body 303 SS Internal components Cast Aluminium and SS Flow Capacities All suitable for use with oil water and oil water emulsion Size 0 0 5 7 GPM 6 25 l min Size 1 5 26 GPM 20 100 l min Size 2 21 100 GPM 80 380 l min Max Working Pressure 6 000 PSI 420 bar Capability Reverse flow STI only Pressure Drop Dimensions inches mm At max rated flow A
71. nnels Fluid Type 3 Contact Parker Hannifin USA Accessory Part Numbers Hose Kit Bag ACC6NNO29UK RJ45 LAN Connector Cable ACC6NE028 includes one power pack ACC6NNO29EUR RJ45 patch cable and low ACC6NNO029US pressure hose BS Carry Strap ACCGNNO30 The Carry Strap option Pressure Reducing Valve PRV ACC6ONNO27 MUST be selected at Standard with the time of placing the IOS 1220 IOS order Low Pressure Hoses ACC6NNO31 Power Pack UK 2m cable ACC6NE023 4mm and 6mm Power Pack EUR 2m cable ACC6NE024 ee High Pressure Hose Assembly Standard with IOS 1220 Power Pack US 2m cable ACC6NE025 Verification Fluid SER MISC 067 icountMS Range Moisture Sensors Fast reliable and accurate inline detection of moisture in fluids MS moisture sensors provide fast reliable and accurate inline detection of moisture in fluids Technology developed for preventative maintenance programmes MS200 is the Programmable sensor monitoring and reporting relative humidity RH moisture content in oils MS300 Intrinsically safe sensor ATEX certified for use in hazardous Zone 0 environments Product Features e MS moisture sensors provide fast reliable and accurate inline detection of moisture in fluids Technology developed for preventative maintenance programs e MS200 Programmable sensor monitoring and reporting relative humidity RH moisture c
72. olely responsible for making the final selection of the system and components and assuring that all performance endurance maintenance safety and warning requirements of the applications are met The user must analyze all aspects of the application follow applicable industry standards and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems The operation of the products described here in is subject to the operating and safety procedures details of which are available upon request Sales conditions The items described in this document are available for sale by Parker Hannifin Corporation its subsidiaries or its authorized distributors Any sale contract entered into by Parker will be overned by the provisions stated in Parker s standard terms and conditions of sale copy available upon request icountOS How To Order 10S1220EUR Mineral Online No options 051210 MTD Offline No options IOS Mineral 2 1 Offline No options 3 Aviation fuel 2 Online EUR 4 cha
73. ontent in oils 6 000 PSI 420 bar MAOP e 5300 Intrinsically safe sensor ATEX certificated for use in hazardous Zone 0 environments 6 000 PSI 420 bar MAOP Temperature Outputs on all versions icountMS Range Features and Benefits e Continuous online moisture indication for e A purpose designed tee adaptor allows for hydraulic and lubricating systems easy installation into an existing fluid system e Reporting of 96 relative humidity of water e The MS200 can also be specified with a content giving the user information on how bench top wand offering the end user greater close to the fluids real saturation point flexibility e Reliable data the rate of water absorption e oensing cell technology using a laser trimmed thermoset polymer for capacitive sensing that is capable of absorbing water molecules due to its micro porous structure e Uses a thermistor for temperature compensation correction Offering total confidence in reporting the 96 RH relative humidity over the sensors temperature range Typical Applications e Ground support vehicles e Earth moving applications e Pulp and paper plants e Agricultural e Marine hydraulics e Hazardous Areas Zone e Power transmission amp e Simulators distribution e Forestry e Industrial hydraulics In Line Moisture Measurement of Hydraulic amp Lubricating Fluids Parkers Moisture Sensor Range offers fast reliable and accurate in line detection o
74. or all other fluids consult factory No specific bottle required Maximum size 2 95 Dia x 5 90 H Maximum volume 250ml 500 tests capacity warning after 450 tests Backlight 256 color STN transmissive 320 x 3 RGB H x 240 W dots 115 H x 86 W mm Via icon driven resistive touch screen Thermal dot line printing 50mm 57mm x 25mm Calibration amp Certificate of Conformity DC output 12V 6 60Amps 80 watts max AC input 100 to 240V 1 2Amps 50 60 Hz 2 hours recommended to be fully charged every 3 months 1 month then 1 hour of operation 6 3 Amps anti surge 50 psi 3 5 bar internal mini compressor or 101 psi 7 bar shop air 21 icountBS Bottle Sampler Ordering Information IBS3100US IBS3000FUS fuel version IBS3000MUS minilab version 250ml Sample Bottle 2 pk ACCeNWOO 2 pks Sample Bottle Pack 50 ACC6NWOO02 Vapour Waste Bottle ACC6NWO003 Waste Bottle Folder ACCG6NWOO04 Printer Paper Reel x1 ACCG6NWOO5 Transport Case P893865 i 1m Waste Tube Clear ACCG6NWOO9 s 1m Vapour Hose Blue ACCG6NWO 10 USB Memory Stick ACC6NWO01 1 icountBS CD Manual ACC6NW012 893318 These items included with IBS unit within a transportation case Single Point Sampler Online Sampling The effective link to ensure accurate mineral based fluids contamination monitoring The SPS Single Point Sampler is
75. ormat is CSV Download and save all log data from the icountOS File format is XML Clear all logged data from the icountOS Recent Samples Data loggeng is Enabled and sampling the IOS every 10 seconds Date Time 105 Result RH 13 03 2011 22 08 11 150 15 14 13 13 03 2011 22 12 33 NAS 10 13 03 2011 22 1243 8 13 03 2011 22 34 18 150 13 12 12 13 03 2011 22 34 28 150 17 16 14 Logged 9 records Used Space 480 bytes Free Space 8 388 128 bytes icountOS Web Interface Unit Status 6 Unit ID Unit Status Page Key Alam Staus Last Result 4 4 Relative Hurnidity SH 50 1 The Unit Status page is a list of ea Um current values for various 2 parameters for the connected IOS m u n it Iurrilwer OMOMO0 Software Version 1 5 2 Software Build 1 5 2 001 135 Last Callibrated 01 01 06 Callibration Due Date 01 01 06 Power Status Running on Power Supply icountOS Limits 19 18 15 Limit 50 icountOS Configuration Key 4 Limit 6p Limit Limit 1 Alarm limit settings for Relative Humidity Limit D 4um channel channel Measurement Period seconds 14 channel Data Logging Interval seconds Unit ID Measurement period Data logging interval Unit name Unit location Unit Location Save Settings Set Date and Time Set Reporting Standard QUI ds aN Configuration Page Alarm l
76. ound the world In the construction and mining In the defence industry IOS The IOS is the primary diagnostic sector IOS is ideally suited to provides essential condition instrument to help automotive service and fluid monitoring of monitoring support for mission manufacturers develop predictive essential equipment and services critical front line battle tanks and monitoring programs military vehicles Ease of on site use light weight Accuracy and speed of use make In the aviation sector the ability to and portability are key IOS features the IOS ideal for wind turbine meet strict quality controls makes for monitoring fuel quality in military engineers for both rountine the IOS the ideal choice for ground bulk fuel installations in theatre maintenance and emergency handling support companies repairs flushing and commissioning ensuring clean and dry fuel deliverance 43 icountOS How Works The IOS quality condition monitor for hydraulic oils and hydrocarbon fuels uses advanced technology to produce extremely repeatable results At the heart of the system is a sophisticated laser detector using a light obscuration flow cell providing continuous measurement of fluid flow passing through a sample tube Measurements are taken every second as standard although measurement intervals and test period can be defined by the user with results being reported immediately and updated in real time Data is displaye
77. p is 16 psi 1 1 bar mineral oil fluid at 30 cSt 140 E SSU TIT Ee m Size 1 G12 dedi seem Repeatability 1 FSD Accuracy Flow 2 5 full scale deflection Ordering Information Weight size 0 1 2 Ibs 0 5kg Standard products table Size 1 8 4 lbs 3 5kg Size 2 9 Ibs 4 4kg Aggressive Fluid Applications 5110144100 STL 0344 00 57 Mineral SAE6 EPDM internal external seals STH144100 5 1 1344 100 1 5 26 Mineral SAE 12 2 20 09 Mineral 67 sree meme Note 1 Part numbers featured with bold highlighted codes will ensure standard product selection Note 2 Alternate displayed part number selection will require you to contact Parker Filtration for availability Note 3 Mobile Sensors are also available Contact Parker Note 4 Accuracy 5 5 gt 25 gpm Applies to STI1144100 STI1148100 only System20 Electronic Monitor Specification Construction A sealed assembly requiring no routine maintenance or adjustment Body molding in ABS Key pad molded in silicon rubber The monitor is suitable for use with all mineral oils water and oil water emulsions Display Details Flow section The analog flow scale has reverse flow and overflow indication and provides a percentage reading of the digital full sc
78. products table icount ACM20 icountACM20 U icountACM20 EURO K US icountACM20 N N N N icountACM20 with lab kit UK DEFSTAN 9191 N icountACM20 with lab kit US DEFSTAN 9191 N icountACM20 with lab kit DEFSTAN 9191 N icountACM20 Z2 online kit amp UK battery charger N icountACM20 Z2 online kit amp US battery charger N icountACM20 Z2 online kit amp Euro battery charger icountACM20 Z2 online amp lab kit UK battery charger icountACM20 Z2 online amp lab kit US battery charger icountACM20 Z2 online amp lab kit Euro battery charger B84794 1 meter process cable B84816 Parsmart downloader software P843855 icountACM20 transit Case B84746 Vapour waste bottle assembly B84745 Throttle kit B84645 Millipore adaptor kit B84609 Re chargeable battery pack B84817 UK power supply B84830 US power supply B84831 Euro power supply UK Offline kit B84832 Euro Offline kit US Offline kit A A A A A A A A A A N 500ml verification fluid B84702 Printer reel x5 P843702 Printer ribbon x1 B84647 UK battery charger B84652 US battery charger B84653 Euro battery charger B84650 2m process cable assembly P843066 Carry case overload protection Spare supplied Patented flow cell light obscuration As per or better than ISO 11171 icountACM20 rear view Transfer Pump Flush Button Transfer Pump On Off Switch ed for Link
79. r custodian for all or any part of Buyer s property c the filing of a petition for relief in bankruptcy of the other Party on its own behalf or by a third party d an assignment for the benefit of creditors or e the dissolution or liquidation of the Buyer 18 Governing Law This agreement and the sale and delivery of all Products hereunder shall be deemed to have taken place in and shall be governed and construed in accordance with the laws of the State of Ohio as applicable to contracts executed and wholly performed therein and without regard to conflicts of laws principles Buyer irrevocably agrees and consents to the exclusive jurisdiction and venue of the courts of Cuyahoga County Ohio with respect to any dispute controversy or claim arising out of or relating to this agreement Disputes between the parties shall not be settled by arbitration unless after a dispute has arisen both parties expressly agree in writing to arbitrate the dispute 19 Indemnity for Infringement of Intellectual Property Rights Seller shall have no liability for infringement of any patents trademarks copyrights trade dress trade secrets or similar rights except as provided in this Section Seller will defend and indemnify Buyer against allegations of infringement of U S patents U S trademarks copyrights trade dress and trade secrets Intellectual Property Rights Seller will defend at its expense and will pay the cost of any settlement or d
80. ration Ordering Information MS200 Product Configurator n weews o No G 1 4 BSP Bonded Seal G 1 4 BSP Integral Seal L NPT Taper D E 2 Programmable 2 Mineral or 1 rs agressive o2 9 5 2 ros 4 20 ma 9 16 18 UNF 2A Integral Seal Hand Held Unit 7 3 8 BSP Female Swivel Equal T Adaptor MS300 Product Configurator BSP Bonded _ 1 swa 3 Programmabie 2 Mineral 4 20mA 4 BSP E Aggressive H 1 4 Taper 1 4 NPT Taper 9 16 18 UNF 2A Integral Seal G 3 8 BSP Female Swivel Equal Tee Oilcheck Hand held Oil Condition Monitor Portable and battery powered for go anywhere monitoring Hand held condition monitor provides a visual comparison between new and used oils Parker s Oilcheck is completely portable and battery powered with a numerical display that indicates positive or negative increase in dielectrics Oilcheck gives an early warning of impending failure and the simplistic hand held design makes it easy to use TE LJ olicheck p d Product Features e Oilcheck hand held condition monitor provides a visual comparison between new and used oils e Completely portable and battery powered e Numerical display shows positive or negative increase in dielectrics e Gives e
81. rds This guidebook is aimed at engineers technicians and quality control personnel involved in contamination control Its purpose is to make available accepted and widely used cleanliness specification levels for liquid samples The tables in this guide allow users of using automatic portable particle counters to see the relationship between raw particle counts at various sizes and the reporting code numbers of various contamination standards A NOTE ON THE FIGURES USED Note that some of the table entries are defined as cumulative counts e g gt and others are defined as differential counts e g 6 14 Instances of particle sizes given as um refer to ACFTD i e Air Cleaner Fine Test Dust distributions Instances of particle sizes given as um c refer to MTD i e ISO Medium Test Dust distributions All standards are in counts per volume and provide easy methods for converting particle counts into limits that are simple to interpret By noting the requirements of the standard particle counts can be accurately converted to contamination levels ISO Cleanliness Code Hydraulic Fluid Contamination 20 000 40 000 10 000 20 000 5 000 10 000 2 000 5 000 1 300 2 900 640 1 300 320 640 160 320 80 160 40 80 20 40 10 20 2 10 26 5 1 3 29 0 64 1 3 Suggested Acceptable Contamination Codes 23 21 17 Low pressure systems with large clearances Ram pumps 20 18 15 Typical cleanliness of new
82. rs Effective in line system sensors and monitors In line System20 sensors and hand held monitors designed to give accurate and instant fluid system readings of flow pressure and temperature 3 sizes of inline System20 sensor for pressures up to 6 000 PSI 420 bar an analog monitor that utilizes 3 day glow gauges with protective cover EM20 electronic monitor with full digital display and 300 test memory Product Features e 2 types of System20 sensor are available STI industrial with reverse flow capability STS mobile without reverse flow capability e 3 sizes of industrial inline System20 sensor for pressures up to 6 000 PSI 420 bar 2 sizes of Mobile System20 sensor e Analog monitor utilizes 3 day glow gauges with protective cover e EM20 electronic monitor with full digital display and 300 test memory e For use with all mineral oils water and oil water emulsions System20 Features amp Benefits Covering a wide range of flow rates fluid types and applications Parker s System 20 sensors are designed to be used with System 20 electronic or analog monitors icountLCM icountPD and the Specially developed System20 sensors are available for use with phosphate ester fluids EPDM Seals e System20 monitors combined with the inline sensor give the user accurate and instant readings of flow pressure and temperature without the need for costly system downtime e For use with all mineral oils water a
83. s recorded against time As the particle moves across the window the amount of light lost is proportional to the size of the particle This reduction in voltage is measured and recorded This voltage lost relates directly to the area of the particle measured is changed into a positive voltage and then in turn changed into a Capacitance value This value is counted and stored in the icountLCM computer in one of 6 channels according to particle size Readouts are displayed on the hand held LCD in the accepted ISO and NAS standards ready for hard copy printing or RS232 computer download The on board computer allows storage of up to 300 test results icountLCM20 Portable Particle Counter Specification ABS structural foam and injection moulded case ABS handheld display Mechanical composition Brass plated steel stainless steel and aluminium e e Fluorocarbon seals Perfluoroelastomer seals Nylon hoses kevlar braided microbore Stainless steel armoured hose ends 1 2m fluid connection hose Rechargeable battery pack 12Vdc power supply Fast blow fuse Unique optical scanning system Bonded glass optical window enclosed in SS plate Micron channels analysis Six Analysis range ISO 7 to 22 incl NAS 0 to 12 32 character dot matrix LCD Alpha numeric keypad Data retrieval Calibration to ISO standards Viscosity range 2 to 100 cSt 500 cSt with SPS Operating temp 41 F to 176 F 5 C to 80 C
84. tweight and robust the truly portable IOS makes field analysis simple quick and easy Able to sample directly from a hydraulic reservoir barrel vehicle fuel tank or from a high pressure online hydraulic system with the addition of a pressure reducing adaptor the IOS is undoubtedly the most adaptable contamination service tool available today The system is completely self contained with laser detection particle counter battery and pump plus memory with web page generator for data download onto any PC or laptop combined into a single unit The IOS uses Parker s proven laser detection technology which delivers precise repeatable reproduceable results in real time detection of both particulates down to 4 microns and dissolved water Just as importantly the IOS has been developed to offer a wealth of features combined with simplicity and ease of use at a cost that is far lower than competing systems and which fits within most maintenance budgets Powerful and easy to use Lightweight and portable Wherever Whenever you need to 100 sure of Oil and Fuel Quality With its robust carrying case sealed to IP67 and proven laser and diagnostics technologies the IOS is the perfect tool for maintenance and plant engineers to use with all fixed and mobile plant and machinery IOS technology is proven in many different applications under the most demanding conditions and is used by leading companies ar
85. uality protection for engines operating in any environment anywhere in the world Legal Notifications J N WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH PERSONAL INJURY AND PROPERTY DAMAGE This document and other information from Parker Hannifin Corporation its subsidiaries and authorized distributors provide product and or system options for further investigation by users having technical expertise It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog Due to the variety of operating conditions and applications for these products or systems the user through its own analysis and testing is solely responsible for making the final selection of the products and systems and assuring that all performance safety and warning requirements of the application are met The products described herein including without limitation product features specifications designs availability and pricing are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice Offer of Sale The items described in this document are hereby offered for sale by Parker Hannifin Corporation its subsidiaries or its authorized distributors This offer and its acceptance are governed by the provisions stated in the Offer of Sale Copyright
86. ve PRV ACCGNNO27 1 300 cSt 40 140ml minute controlled at G0ml min by IOS s internal pump INLET 236 inch 6mm push fit DRAIN 157 inch 4mm push fit 409 to 80 C 40 to 176 F 309 to 80 C 229 to 176 F 5 RH to 10096 RH 5 C to 80 C 41 F to 176 F 209 to 70 C 4 to 158 F Linear scale within the range 5 RH to 100 RH IP68 rated RJ45 connection that may be connected to a laptop computer s RJ45 LAN port using the 2m cable supplied Regulated power supply supplied with the unit IP54 rating unit open IP67 rating unit closed EC Declaration of Conformity Machinery Directive EMC EN61000 6 3 2001 EMC EN61000 6 2 2001 EMC EN61010 1 2001 CE Certified Offline IOS 1210 EUR UK US 1x IOS Oil Sampler Unit 1x Power Supply 1x RJ45 LAN Cable Low Pressure Hoses Online IOS 1220 EUR UK US 1x IOS Oil Sampler Unit 1x Power Supply 1x RJ45 LAN Cable 1x Low Pressure Hose 1x PRV 1x High Pressure Hose Important Information WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH PERSONAL INJURY AND PROPERTY DAMAGE This document and other information from Parker Hannifin Corporation its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise The user through their own analysis and testing is s