1. Adjust the LCD contrast using a small screwdriver Remove the top of the control box and make sure the cable connection between the LCD to the circuit board is securely connected Reset the device Motors do not vibrate at all or do not vibrate in the correct pattern Make sure the device is in the proper mode Reset the device Make sure all cable selections are secure Check the battery level Contact a service technician or doctor qualified to calibrate the device and have the system recalibrated Data cannot be retrieved from the device Make sure the device is in upload mode Make sure the correct IP address is entered in the browser window Make sure a crossover cable is being used to connect the device to the PC If troubleshooting does not solve your problem contact the manufacturer for additional troubleshooting options service or replacement
2. Secure the control box to the calf of the leg using the straps on the back of the box The motor cable should be at the top of the calf Wrap the motor feedback strap around your thigh fastening the attached clip so that it is tight but not so tight that it becomes uncomfortable Connect the plug of the motor strap to the motor strap cable of the control box Then fasten the clinometer strap to the prosthetic just below the knee making sure the clinometer is on the side of the leg Connect the clinometer to the control box using the appropriate plug Finally put on the shoe containing the sensors and connect it to the sensor cable of the control box General Informative Medical Prosthetic User Manual Use Instructions The General Informative Medical Prosthetic has three different modes direct map training and upload The current mode and battery level are displayed on the LCD located on the front of the control box The current mode is displayed on the top line and the battery level is indicated by the number of symbols on the bottom line More symbols indicate a stronger charge and no symbols indicate a dead battery On startup the device is in direct map mode Turning the control knob scrolls the bottom line of the display through the modes and pressing the knob sets the mode shown as the current mode In direct map mode the device vibrates a certain pattern of motors in the feedback strap in response to pressures detected by th
3. General Informative Medical Prosthetic User Manual Introduction Thank you for choosing the General Informative Medical Prosthetic G I M P This system is designed as an accessory to a typical prosthetic leg and will assist you in the use of your medical prosthetic by providing sensor feedback of the pressures being placed on the bottom of the prosthetic foot For users who are still learning to walk with their prosthetics the system also provides a training mode to help them learn to walk properly The G I M P system will help users maintain balance by monitoring four thin pressure sensors placed in the sole of a typical shoe and a clinometer attached to the calf which measures the angle of the lower leg The main control unit worn on the calf then maps the pressures detected to the user through a cloth strap containing ten vibration motors worn around the thigh Depending on where pressure on the foot 1s detected the motors will vibrate at the front back left and or right side of the strap The control circuitry can be contained in a box strapped to the prosthetic calf or ideally it can be placed in the core of the prosthetic to reduce excess bulk added to the prosthetic The system will also help those new to using a lower limb prosthetic device learn to walk correctly with their prosthetic The system has a training mode designed to teach the user how to walk by vibrating the motor strap in a particular order to indicate to the user whic
4. e sensors in the sole of the shoe For example pressure on the heel of the foot will activate motors at the back of the strap while pressures on the toe will activate motors at the front of the strap In training mode the device vibrates the motors in a sequence to prompt the user to perform the next action needed in the process of taking a step The actions indicated by the motor combinations are indicated in the following table Training Mode Motor Patterns all motors on lift leg back motors on apply pressure to heel of foot side motors on apply pressure to ball of foot front motors on apply pressure to toes Once the sensors detect the correct action the motors for the completed step are turned off and the motors for the nest step of the sequence are activated In upload mode the device can be connected to a computer using a standard network crossover cable and statistics about the device usage can be viewed by a standard web browser Entering the IP address 192 190 2 5 in the address bar of the browser will trigger the device to display the usage data currently stored in the device to the browser window Troubleshooting Problem Solutions Problem Solutions Problem Solutions Problem Solutions General Informative Medical Prosthetic User Manual Device will not power on Check the battery level Make sure the battery connection is secure and retry Device powers on but the screen is blank
5. h way they need to move or apply pressure to the prosthetic In addition the system 1s capable of recording data about the device usage for review by a doctor or therapist General Informative Medical Prosthetic User Manual Left Side View L Sa Power Contrast Control Switch Adjustment Knob Right Side View F E F i h Display Vibration Motor Feedback Strap oe General Informative Medical Prosthetic User Manual Setup Instructions Installing the battery Loosen the screw in the control knob and remove it Then remove the retaining nut from the control knob shaft Remove the six screws securing the top of the case and lay the top to the side being careful not to pull out the cable attached to the LCD screen Remove the retaining nut from the power switch and remove it from its hole in the case Gently pull up on the circuit board on the side opposite the control knobs until it is free from the case and lay it to the side as well Place a 7 2 volt RC battery in the battery straps located in the bottom of the case and connect it to the battery cable of the circuit board Replace the circuit board in the case by placing the control knob shaft through the appropriate hole in the case and then gently pressing the opposite side of the board into place Replace the power switch refasten the top of the case and reattach the retaining nut and control knob to the control knob shaft Wearing the device

Download Pdf Manuals

image

Related Search

Related Contents

見る - JVCケンウッド  "user manual"  Offspring Technologies GoldX Web Camera  Notice Gmaxx - King Detection  Remote control operation procedure  取扱説明書(PDF/4.15MB)  FDA Approves Updates to Lilly`s Humalog® (insulin lispro injection  Samsung MS23J5133AM Manual de Usuario  ColorBlaze TRX Product Guide  Qubit® dsDNA BR Assay Kits - UTA  