Home

Flexible TPN and general infusion pumps for

image

Contents

1. Ambulatory Twin Channel Infusion Pump Infusion Pump land general infusion pumps for inpatient and homecare use cme medical Listen gt Develop gt Deliver You gain maximum flexibility from the BodyGuard 323 Ambulatory Infusion Pump and the BodyGuard 2CH Twin Channel Infusion Pump Both pumps are suitable for TPN and general infusion in hospital at home or on the move Applications Intended use e Total parenteral nutrition e Parenteral e Critical care e Intravenous e Patient transport e Subcutaneous e Emergency medicine e Percutaneous e Fluid replacement e Intra arterial e Lipids Enzyme replacement Modes of operation TPN with optional ramp up down pattern Continuous rate over volume or volume over time Multi Step up to 25 steps at different rates Intermittent Twin Channel only for dose protocols at set intervals Dose Twin Channel only for weight based dosing When you need a system which is accurate and reliable in all applications e The BodyGuard pumping mechanism ensures unparalleled accuracy and linearity of infusion even at the lowest rates to meet the standards of your most demanding specialities Adjustable air in line detection and occlusion pressure settings help to prevent nuisance alarms e The Post Occlusion Bolus Reduction System will safely release pressure from the line following an occlusion without administering a potential post
2. Pump Paused Too Long unattended End Program End Battery Missing Key Restart Pump System Technical Problem Wrong TPN Data Lock Mode Fatal Error BodyGuard 2CH Twin Channel Infusion Pump Piston mechanism ambulatory infusion pump with two independent channels 89mm height x 149mm width x 41mm depth AC mains power 110 240VAC 50 60Hz 0 3A max Battery rechargeable Li polymer 7 4V 1800mAh typical 7 5h infusing E 125ml h both channels infusing simultaneously Total parenteral nutrition TPN continuous 25 step intermittent dose o 1ml h to 100mI h in o 1ml h increments and 100ml h to 1 200ml h in 1ml h increments Low Battery Program Nearly Complete Air Upstream Occlusion Down Occlusion Door Open Pump Paused Too Long unattended End Program End Battery Missing Key Restart Pump System Technical Problem Wrong TPN Data Lock Mode Fatal Error CME Support by your side throughout Technical support Your technical support needs are our priority As an ISO 13485 certified support facility we can offer you high quality technical support and training with services developed by our customers for our customers You and your team will benefit from market leading technical training and support services We will work with you to ensure you receive the best possible service package for your needs TRAINING Your role as biomedical engineer in supporting and maintaining these s
3. occlusion bolus e Adelayed start infusion option means no reminder and no additional clinical intervention is needed once the pump has been set up for general infusion When you need a system which is quick and easy to use allowing you more time for your patient e Configurable modes of operation that can be set to patient speciality are available limiting set up time and possible errors e Intuitive design means both pumps are quick and easy to programme When you need a safety enhanced system which puts you in complete control The built in event log automatically records accurate and reliable data on pump use e The lockable keypad prevents most inadvertent key presses A range of alerts and alarms will draw immediate attention to any pump status requiring intervention When you need a pump which allows your patients to be treated at home e The intuitive user friendly design enables patients to confidently and safely operate the pump themselves e The integral rechargeable battery gives them full mobility and freedom e They have a choice of rucksack colours and sizes to safely easily and discreetly carry their device in style And to feel as comfortable as possible in hospital e The accurate and reliable delivery system gives patients the peace of mind to concentrate on their rehabilitation They have the freedom to ambulate with or without a drip stand Pumps Product code Description SBOM323A BodyGua
4. 100 072XA AC mains lead Administration sets Product code Colour Patient Bag spike Length Free flow Additional features connection Priming vol protection 120 112XSFV Luer lock Straight 280cm 1oml Anti siphon valve 1 2 micron filter amp priming valve amp clamp 120 160XSFM Luer lock Straight 270cm 10m Anti siphon valve 0 2 micron filter amp clamp 120 160XSV Luer lock Straight 280cm 7ml Anti siphon valve Priming valve amp clamp 100 160XSM Luer lock Straight 180cm 5ml Anti siphon valve amp clamp 120 000XBS Luer lock Straight 240cm 16ml Anti siphon valve 150ml burette 15 micron filter in drip amp clamp chamber roller clamp Y site All sets are latex free with anti kink tubing Length and priming volume are approximate Technical specification Description Dimensions Mains and battery power supply Battery life Modes of operation Flow rate Alerts Alarms BodyGuard 323 Ambulatory Infusion Pump Piston mechanism ambulatory infusion pump with a single channel 114mm height x gomm width x 40mm depth AC mains power 110 240VAC 50 60Hz 0 3A max Battery rechargeable Li polymer 7 4V 1300mAh typical 11 3h average infusing 35oml h Total parenteral nutrition TPN continuous multi step 0 1Ml h to 100mI h in o ml h increments and 100mI h to 1 200ml h in 1ml h increments Low Battery Program Nearly Complete Air Upstream Occlusion Down Occlusion Door Open
5. al co uk D V N INVESTORS V V 4 IN PEOPLE MKG3232CHGEN13
6. ining as your organisation moves forward BodyComm BodyComm is an easy to use configuration software programme which enables efficient and flexible management of all infusion protocols stored in your BodyGuard 323 Ambulatory Infusion Pump Use BodyComm to e Download save and print a record of the last 512 sequential stored events including alarms from your pump event log for display in text and graphic format Data captured for each event Date amp time e Flow rate e Volume infused e Volume to be infused Protocol data naum e one ae Pe O ERE F eS j z 2 4 i y 25255 z Hre ia a e Battery or AC power nunni e State of operation pump operating alarming etc e Event number e Pump serial number Our complete range of specialist infusion devices Ambulatory Syringe Pump Ambulatory Syringe Pump Pain Management Syringe Pump BODY BODY Geb G29 q BODY Gc Ambulatory Infusion Pump Twin Channel Infusion Pump BODY cas BODY BODY 695 GUARDES GUARD GUARD Epidural Infus n Management Infusion Pump Regional Analgesia Infusion Pump For more information please contact us using the details below Head Office Southern Office Kincraig Business Park Milton Park Innovation Centre Kincraig Road 99 Milton Park Blackpool FY2 oPJ Abingdon OX14 4RY Fax 01253 896648 Fax 08704416093 Central Switchboard email info cmemedical co uk 01253 894646 www cmemedic
7. ophisticated devices is a very important one That is why we offer a range of technical training courses and materials which are designed to give you the knowledge and skills to expertly support your chosen devices EQUIPMENT REPAIR AND SERVICING Our team of highly skilled engineers will support you by ensuring competitive turnaround times Prompt spare parts order fulfilment is guaranteed by our significant stock holding capability SERVICE CONTRACTS When entering into a service contract with CME Medical a partnership is formed to ensure your requirements are identified and addressed from the outset Clinical support You and your team need the confidence to competently and safely operate your chosen infusion devices That is why we have developed a range of education programmes which are based on current and well established principles of learning and training strategies and which follow national standards for medical device training Your competency based training can be delivered either face to face or via e learning We can offer both at the point of purchase and periodically as required Your dedicated Clinical Support Specialist will work with you to develop a training plan which is tailored to your local needs fit for purpose and which will help you to achieve your training objectives Emphasis will be placed on intensive training for your advanced users allowing you to take control of your own cascade tra
8. rd 323 Ambulatory Infusion Pump Includes pump internal standard life Li polymer battery 1 800mAh charger base no LED display user manual AC mains lead and DC charging cable 100 510PXSDC BodyGuard 323 Ambulatory Infusion Pump only SBOM121D BodyGuard 2CH Twin Channel Infusion Pump Includes pump internal standard life Li polymer battery pole mountable LED charger unit user manual and AC mains lead 100 901PTM BodyGuard 2CH Twin Channel Infusion Pump only BodyGuard 323 Accessories Product code Description 150 000X Carry pouch reusable washable 100m 150 001X Carry pouch reusable washable 250ml 160 002XB 2 litre rucksack black 160 002XG 2 litre rucksack grey 160 002XP 2 litre rucksack pink 160 001X 3 litre rucksack navy blue 130 050X2 Battery adapter 2x9V 196 000X DC charging cable 150 331X Desktop charger 150 314X Charger base LED display amp DC charging cable 150 314XM Charger base no LED display 130 O50XA Standard life Li polymer battery 18800mAh 130 051X Extended life Li polymer battery 3600mAh 100 072XA AC mains lead SBOMBODYCA BodyComm kit for BodyGuard All carry pouches accommodate pump lockbox and fluid bag BodyGuard 2CH Accessories Product code Description 160 002XB 2 litre rucksack black 160 002XG 2 litre rucksack grey 160 002XP 2 litre rucksack pink 160 001X 3 litre rucksack navy blue 150 3131 Charger base LED display

Download Pdf Manuals

image

Related Search

Related Contents

Operating Instructions - Global Energy Associates Ltd  aAa - A-Audio Luxury Headphones  bedienungsanleitung office 45 - tk    Rangemaster Baltimore Compact  EPSON LP-8200CPD 取扱説明書  scarica il manuale - K  Massive Wall light 17090/30/10  Tripp Lite Cat6 Gigabit Snagless Molded Patch Cable (RJ45 M/M) - Yellow, 3-ft.  

Copyright © All rights reserved.
Failed to retrieve file