Home

User Manaul For Ambery Professional 2

image

Contents

1. Corporate Website Support Contact Support ambery com PRODUCT INTRODUCTION usina 2 APPLICATION S caia bed 2 1 2 POWER CONTROL AND MONITORING DIAGRAM ooooccccccnnnnccononoonncnnnnncnonnnonnnnnnnnnoronnnnnnnnnnnnnnnnnns 3 9 PRODUCT FEATURES sie 4 14 GONTROGANDINDICATORS ed de 5 160 PEC A MON Sado ne canon 6 126 PACKAGE CONTENTS iodo 6 1 7 INSTALLATION AND SETUP tt A a Bean 7 1 7 1 HARDWARE INTAULA TIO Nissan E E 7 1 7 2 SETUP PROCEDURE iaa EA 8 o WEBPAGE OPERATION cana 9 2 SYSTEM SETUP aaa aaa 9 2 LNE TWORK SETUP iio 10 223 TIME SYNCHRONIZATION ada 11 21 POWER MONITOR nacido 13 2 4 1 POWer Switeh SetU pcrea ocean ieee Ad les A herder a asec eck 13 2 4 2 POWer Switch Operations ado 14 s ADVANCEMENT SETUP inicia ica 14 OP TPOWER MONTOR ceina aio ie 14 3 11 POWE Opera a th bat eaves dadaed tase danidselan deena Adeee rads 15 3 1 2 Power Configuration Setup ccccccsssccccccssssececceeseeeecseeeseeeeesseseeeesseeaseeeesssaseeess 15 3 19 Working SCHOQUIC sia dea hee cece 15 A A 16 JL SYSTEM OETUP oe aaa calar Urano a 16 O21 INGCTWOIK SCD ais anida ici 17 372 2 EMail SEV SOU A ee 17 3 2 3 Message Server SOUND tati 18 SA e O PR O OU Oo E 19 3 20 Oher Setup iaa 20 3 3 USER ACCESS ACCOUNT MANAGEMENT 00 csseccecccceseeeecccceseeeeesecssaeeeesecssneeeeseceseeessees 20 3391 Add An Ser AGCOUMM dad LSE cao ela als ck oi 20 3 0 2 Delete An USEF ACCOUN eraren T A ANa 21 3 4 TIME SYNCRONIZATION visado debia 2
2. The system date of the remote power switch Equipment Time The system time of the remote power switch sync with PC If you choose this item the equipment time of the remote power switch will be the same as the computer system PC Date The current computer system date PC Time The current computer system Time sync with NTP Server If you choose this item the equipment time and Time Server will be identical NTP Server Address This switch provides several Time Servers for choice If there is no time server info you want in the list you may also add a new Time Server info by yourself and then set up the time Press New button when the window below appears input the NTP server address and then press OK 22 3 5 Event Log In this section you may check the log of all the power operations and warning events in the recent 7 days You can find out what power action occurred on what outlet and at what time by access remotely or locally from the web panel At the same time if the power switch can not operated normally it will produce warning case 2 Operated Event O Warning Event 006 0321 09 43 56 006 0321 09 40 53 2006 0321 09 40 53 006 0521 09 40 54 006 0521 09 40 54 2006 05 21 09 40 55 2006 0321 09 40 55 2006 0321 09 40 57 2006 03 21 09 40 55 2006 0521 09 40 59 2006 03 21 09 40 59 00605321 09 49 00 006 0521 09 49 01 software Reboot Port 1 First Cutlet Power On Port 2 Second
3. be kept the same as before Both the user id and password for the web access session will be back to admin for ID and admin again for the password gt The network IP address of this switch will be 192 168 1 10 gt The rest of the system setup data will remain unchanged Reset Indicating Light Reset Button 24
4. 1 Add An User Account Account Set up the user id of each user account here Password Set up the password of each user account here Cell phone This is an optional setup if SMS messenger server is available Enter contact phone number here when the alert SMS text message needs to be transmitted via the designated SMS server Mail Address Enter contact email address here when the alert message needs to be transmitted by email service Administrator or system manager of this power switch can also assign the access levels 20 for each user account For example manager can assign user A to access either all 2 power outlets on the switch or just a particular one outlet is allowed for access 3 3 2 Delete An Use Account Mal Address Choose and mark to delete User s Data Ep Press Delete button to proceed the action of deleting User s Data After deleting the data you must press Save button to store the changes in setup Hj 3 4 Time Synchronization Equipment Time Equipment Date yyy y mim dd 2006 03 20 Equipment Time hh mm ss 15 45 07 System Time PC Date yyyy mim dd 0086 03 40 PE Time hh mm ss 15 45 07 i ee path E ITE En Til H F L LIP Lr ca OWA with MIF oe rye NTP Serer Address time stdtinme gov bu Time Zone GwT 00 _ Manual Setup Date lyyyy mm dd 2006 03 20 Time hh mm 855 15 45 00 New Cava Equipment Date
5. 7 days 1 7 Installation and Setup 1 7 1 Hardware Installations 1 Connect the power cord to the power inlet on IP P2 model first 2 Plug the power equipment into the output receptacles 3 Connect the Ethernet cable to the Ethernet port 4 Turn the push button on the power switch to the ON position Ethernet HUB 1 7 2 Setup Procedure There are two ways to configure this remote power management unit 1 Open a web browser and input the default IP address 192 168 1 10 if your LAN has the same subnet format as912 168 1 X Then login the web control panel page with the default login name admin and password admin and start to input the information as needed 2 If your LAN has different subnet format please use the utility program from the supplied disc for the initial searching the IP address of the remote power switch Default settings of our remote power manager are IP address 192 168 1 10 Subnet mask 255 255 255 0 Gateway address 192 168 1 1 Account name admin lower case Password admin lower case Things to be noted 1 The local PC and the remote power switch must be in the same LAN environment before configuring the power switch 2 The Windows firewall must be turned off first before running the IP Search Utility program 3 Click Windows Firewall from the control panel in Windows 4 Select Off and then confirms by clicking the OK button in the Windows Firewall setup 5 Launc
6. if needed 3 2 3 Message Server Setup When there is a warning setup the warning message data in the Message Server SMS Server Message Server Setup server Address 192 160 1 4 Port 2500 Equipment Mame Remote Power Management Syster Account admin Password Send SMS SMS Test nave if Server Address Enter the SMS message server s IP address here so the SMS text message can be transmitted to the SMS server when the warning event is triggered by the preset value Port Enter the connection port address for your SMS message server The preset value is 2500 Equipment Name When the receiver gets the text message sent by the SMS server this portion will display the source of the SMS alert event Account Enter the user id of your SMS server if available Password Enter the password of your SMS server if available Send SMS Check here if SMS service needs to be activated for operation setup 3 2 4 SNMP Setup Gy SNMP MIB System System Name Data Center Sysiem Contact Administrator syetem Location Office TRAP Notification Recener IF Address 192 168 1 213 Recewver Por Cormmunity Enabled 1162 public oo lo olo lolas t Sae System Name Display System Name on the program of SNMP Client system Contact Display System Contact Person on the program of SNMP Client system Location Display System Site on the program of SNMP Client Receiver IP
7. 2 3 5 EVENT RECOR Dorii aa A Ads 22 ATTACHMENT A HOW TO RESET THE POWER SWITCH ccccccccssssssseeseeeeessneesseees 23 a oe 1 Product Introduction Congratulations on your purchase of our Smart Remote Power Manager Series product Our IP P2 model is a web based SNMP power control device integrated with versatile functions including power control power operation scheduling remote web administration power event alerts and so on into one single unit which helps system administrators or IT personnel to monitor and control their connected equipment and take preventive measures when needed System administrator can remotely control the AC powered devices connected to this web power switch such as servers routers modems DVRs security systems and telephone equipments By building centralized power control system for power equipments such as UPS power generator fan lighting signage network routers hubs switches DSL Cable modems ATM s servers gateways web cams video cameras firewalls and security surveillance system this remote power switch helps reduce greatly on enterprises IT cost as well as saves MIS personnel s traveling time Other benefits from employing this intelligent power distribution system including e Improves administrative efficiencies with multi outlet power control e Reduces system down time so business operation will not be interrupted e Restores IT assets without dispatching service person
8. Address When something happens to Trap and it is IP site which will be sent to Trap Receiver Port When something happens to Trap and intends to send to Trap server it is the Connect Port for Trap server The inner setup value is 162 Community When something happens to Trap and intends to transmit to Trap server the group will be sent to Trap server Enabled While mark the using option if something happens to Trap Trap Case Information will be sent to the appointed Trap server 19 3 2 5 Other Setups The phone ring setup is designed for phone control mode This system will execute IVR process after several rings If there are no other phone devices attend to the incoming call this power switch will take the call then When this intelligent remote power switch is daisy chained with other phone devices like fax machine or answering machine you can set the lower priority on this power switch by assigning more rings needed so to let users or other phone devices to attend the phone call first e Other Reboot power switch M Reboot Device Save Reboot Power Switch Check this box here if the reboot of the power switch is needed Reboot Device Reboot the switch 3 3 User Access Account Management Click the Account tab from the menu of the web control panel and then proceed to set up the authorizied users accounts and other account access management You may set up to 2 accesss accounts in total 3 3
9. Outlet Power On Port 3 Third Cutlet Power Of Port 4 Fourth Cutlet Power Off Port 5 Fifth Cutlet Power Off Port 6 Sixth Cutlet Power Off Port 6 Sixth Cutlet Power On Port 5 Fifth Cutlet Power On Port 4 Fourth Cutlet Power On Port 3 Third Cutlet Power On Port 2 Second Outlet ower Off Port 2 Second Outlet Power On Click to choose Operated Event or Warning Event and choose date from date bar then press OK button It will show the event information The Download button means that users can save the event log information in cvs format into the hard drive Delete button means to delete the highlighted event information 93 Attachment A How to reset this remote power switch to the initial default value Answer In case that user forgot the password for the web network access to the power switch user can always reset the power switch back to manufacturer s default setting Locate the RESET button first There is a small tiny hole next to the LAN LED indicating light That s where you can reset the power switch You may insert any pointed object like a paper clip into this hole to push gently and hold for at least 3 seconds then release the push Then the remote power switch shall carry out the reboot for system reset Note After the reset this power switch will clear the previous user id and password entry in the memory However the rest of the user access information and other data entry will
10. en the connected power equipment is a network IP addressable equipment you can set up this power switch to ping IP network devices so to confirm the continued operation of the equipment TT PING Interval Time NS ct Times Equipment Network Address Enter the IP address of the network equipment PING Interval Time Set the time Interval to execute the PING function on the network equipment Detect Times If a device fails to respond to a ping continuously and exceeds the preset trial times the switch will send the warning message or email to the qualified personnel Reboot Users can set the power switch to reboot the web device if it fails to respond to a ping continuously and exceeds the preset trial times Re detect Time Users can set the power switch to re detect the connected web equipment here with preset time period in minutes 3 2 System Setup In this section you may learn to set up web network email server and message services 3 2 1 Network Setup IP network information data entry 16 Ym Network 0 Network Setup vay 19216811 Domain Name Server Setup 1168 95 1 1 SHIA ao al 1 L r 1 Lj 4 f Web Server Setup IP Address Assign the Network IP address for the power switch Subnet Mask Set up the subnet mask info of this equipment Gateway Set up the gateway port of this equipment DNS Server 1 Enter your DNS server1 address if any DNS Server 2 Enter your DNS server2 addre
11. eously to cause sudden overloading and effect equipment working 2 Easy web setup for scheduling power operations precisely performed on specific outlet daily weekly monthly and yearly The Auto Ping feature will monitor and auto detect any failed network equipment and perform a timed reboot or other power control function like turning on an indicator or siren IP filter mask function helps manage user privileges and prevent unauthorized access to the control menu through the network Instant email SMS text messages and trap notification will be generated when power events occurred according to the preset values Protected with circuit breaker to avoid power overload and protect connected devices 1 4 Control and Indicators a Main Power Switch amp Breaker Power Switch Indicating Light Protector Reset Indicating Light Power Input Power Indicating Light Yay Power Switch Socket RJ45 Network Connect Port 1 5 Specifications Power Socket NEMA 15R Max Main Output Current 12 Amp Power Input 85 264VAC 47 63Hz Power Frequency 50 60 HZ Operating Temp 0 60C Shape Size 153 x 123 x 44 mm W x D x H Machine Net Weight 0 75 KG Consumption Efficiency 4 5 W 1 6 Package Contents Remote Power Monitor 1 CD Rom with User s Manual 1 Power Cord 1 If any of the above accessories are missed or can t be used please contact with the location you purchased from for replacement in
12. h the IP Search Utility program from the supplied cd disc 6 Click on the Refresh button to search for all of the IP P2 model remote power switch in your local area network t IP Serach Utility IP Address We Refresh D IP IPE dit Gateway GWEdit Configure NetMask NetMaskEdit MAC MACE dit 7 Click on IP P2 to configure the internal local IP address the gateway and the subnet and then click on the Configure button twice You will see the IP address the Gateway and the NetMask Subnet for the selected power switch connected in the list change 8 Once the setup is done completely exit the IP Search Utility program and turn the Windows Firewall back on 2 Web Operation In this Chapter you can learn how to set up this intelligent power controller and configure the network setup system time power basic data and how to operate power switch via network quickly 2 1 System Setup e Open up a web browser on your local computer and then enter hitps 192 168 1 10 to get into the web session of this power manager unit J Remote Power Management System File Edit View Favorites Tools Help Q O ae iddress https 192 168 1 10 e After the login screen appears please enter admin in both user name password columns Connect to 192 168 1 10 fx jser name f A Password _ Remember my password After login you will proceed to see the complete web administration
13. nel to the field e Monitoring and management of power operation from anywhere in the world 1 1 Applications e Monitoring and management of the computer equipment room e Intelligent power management of data center and networking equipments e Power scheduling of all machinery equipment for the factory building e Home appliance power control and monitoring e Other power equipment management scheduling and monitoring 1 2 Power Control and Monitoring Diagram Server 1 3 Product Features 2 Professional IP addressable power distribution unit with built in web server with 2 power outlets Control power equipment remotely via the Internet without the presence of service personnel Amazing power distribution unit equipped with an intelligent current meter True RMS to indicate the total power consumption of a power strip 2 Manual power on off button to override the existing power status and gain immediate control from local access 2 Each AC power outlet can be independently switched on off power cycled for immediate reboots or reboot with timed delays power cycle sequence with assigned priority and power event scheduling Easy LED displays for power status total current and control mode indication 2 Featured with AC RMS current meter built in to display the total current load of the switch from the devices connected Supports Power Start sequence setting to prevent all of switches from starting simultan
14. nually open or close any particular outputlet s power from the web control panel at your networked computer terminal 2 Move your mouse over to each power outlet button icon and left click on the mouse button twice to manually open or close any particular outputlet s power from the web control panel at your networked computer terminal If you want to reboot the individual outlet or the equipment connected to the outlet check the Reboot box and then left click on the mouse button twice to manually reboot any particular outputlet s power 3 Advanced Setup This chapter is mainly to explain the advanced operation in the web control panel You may learn about all the advanced features and functions of Power Monitor System Setup Account Management Time Synchronization and Even Log 3 1 Power Monitor The first main category from the top menu bar of the web control panel is Monitor In the section users can proceed to set up the basic configuration avalanched power operation scheduling and network device scan and detection All these tasks are done through any internet browser 14 3 1 1 Power Operation All 2 power outlets can be managed independently from the web control panel for power operation setups including power on power off or rebooting the power equipment Reboot First Outlet ON Button Icon Illustration O ON OFF OFF NotAuthorized No Power 3 1 2 Power Configuration Setup Desc
15. ote IP power unit plus the new HTTP port number you just assigned e g https 192 168 1 10 8080 in this case 4 After finishing all entry of network info please make sure to store all setup data into the unit by pressing the Save button on the web panel 2 3 Time Synchronization The time zone that our IP P2 model adopts is 24 hour basis so you must set up the timer schedule on this basis to the switch can perform accordingly When accessing this unit for the first time you can have three time sync options to choose from By clicking the Time Sync button form the web control panel you can choose which way to sync with for the system time of your remote power controller 1 Equipment Time Equipment Date yyyy men dd 2006 03 20 Equipment Time hh mm ss 15 45 07 System Time E ss e eee Be mea irre NE Wi th PL PC Date yyyy mm da 2006 03 20 PC Time hh mm ss 15 45 07 Time Zone GMT d Manual Setu p Date iyyyy mm ddi 2006 03 20 Time hh mm ss 15 45 00 Saye There are total of three system time synchronizers from the selection list e Sync with A Local PC Clock select this method if you want to set up the equipment system time to be the same as your PC s date and time displayed in the web panel page e Sync with NTP Server select this time method if you want the system time of this power switch to be the same as Greenwich Mean Time GMT O Manual Setup You may al
16. ription The description column allows for users to name each power output after the connected power equipment or others for the convenience of the system administrator manager to distinguish all power equipments connected from one to another Start Delay Time This column allows users to have each power device connected start up at different moments instead of all starting up at the same time Each power outlet can be programmed to wait for the specified time period in seconds or minutes before startup Shutdown Delay Time Just like the above the start delay time this column allows users to have each power device connected shut down at different moments instead of all shutting down at the same time bart shutdown Delay Time Delay Time 3 1 3 Power Operation Scheduling You may program this remote power switch with timer schedule for action of Lisenption 15 switching the power equipment ON or OFF or reboot in this section EN Schedule Recurrence You can set the recurrence frequency of the power action for each outlet The recurrence can be yearly monthly weekly or daily Time Set up the action time for each power outlet The time entry is on the bottom of the schedule table Action Select which power action to take place ON OFF or Reboot Delete If you want to delete this schedule double click on the X to confirm the removal of the unwanted schedule entry 3 1 4 Network Detection PING Wh
17. screen as the screen shot shown below Ma 2 tee esa ee ue gt smem Oboe 8 mat a 20 C oe Smart Remote Power Manager PP ED VE a ai O 2 2 Network Setup Click on System tab from the menu bar of the web screen and then click on Network next for configuring the IP address and network info of this device Network MSi Network oia JE Aires 1921601 N A serej Domain Name career Setup Web Server ne a 9 7 SPor 1235 OO OOOO O E 10 O Network Setup Please fill in the preferred IP address sub network shade and the gateway info of your local area network If you don t have relevant data on hand please check back with your network system administrator or ISP provider first 2 Domain Name Server Setup Please fill in the DNS server information here provided by the administrator or your ISP service provider If you do not know the DNS server information on your network you may find out yourself by inputting C gt nslookup in DOS prompt i s ns lookup Default Server dns hinet net Address 168 95 1 1 gt amp Web Server Setup When you log into this remote power control unit through a web browser e g Internet Explorer you may change HTTPS communication port to be other value like 8080 if you do not want to use the default port number 443 And then you may re login again to the remote power manager by re entering the IP address of the rem
18. so set up the system time of this power switch manually by entering the date and time you want this unit to be configured in the columns of Date and Time When you finish the date time setup for the above step always remember to press the Save button on the web control panel to save all the setting data in the system LAD 2 4 Power Control Monitor Configuration You can set up each individual power outlet on the switch accordinly with advanced features by clicking on the Monitor tab from the Web control panel as illustrated in the following paragraph 2 4 1 Power Switch Setup Y Configuration tart mhutdower Im Time fresno Il Time Description O Click the Set button located on the top corner of each power outlet icon to set up set up the startup shut down point with or without delay period When the Set button is in orange color the outlet is highlighted and ready for configuration 2 The description colum under the Configuration section allows user to assign a nickname for the purpose of the individual outlet or the kind of the power equipment to be connected to O When finishing the setup for the above outlet please make sure to press Save button to save the configuration that were just done 13 2 4 2 Power Switch Operation _ Reboot 2nd Outlet Reboot 1st Outlet i O Move your mouse over to this section and left click on the mouse button twice to ma
19. ss if any Http Port Assign a HTTP port address here for browsers to be connected to this equipment via HTTP protocol API Port Provide the Application Program to be connected with the appointed connect port to this equipment This product provides API for the user to develop program connected with this equipment to get the power electric current temperature status and control power please refer to the explanation 6 3 You must setup the network vent connecting the program with this equipment 3 2 2 Email Server Setup When there is a triggered warning from the setup of this power switch this device will send out an alert message to the preset email accounts 17 Mail Server Email Server Setup SMTP Server Address SMTP Port 25 Sender Mad Address lll pn Mail Subject Remote Power Switch Alarm SMTP Auth a SMTP Account SMTP Password Mail Test Save SMTP Server Address Enter your SMTP server address here SMTP Port Enter your SMTP port number here The preset value is 25 Sender Mail Address This section displays where the alert email is sent from Mail Subject Enter the topic of the email when the receiver gets the email SMTP Auth If the setup mail server needs to identify the user please mark this item and setup the account and password SMTP Account Enter the user id here for SMTP account if needed SMTP Password Enter the password here for SMTP account

Download Pdf Manuals

image

Related Search

Related Contents

Manual do Usuário  Wash FX User Manual Rev. 1  istruzioni per l`uso - Expert-CM  Achtung - Viessmann  E8a Emulator User`s Manual    SERVICE MANUAL  Samsung GT-E2222 User Manual    

Copyright © All rights reserved.