1. GARDTEC 872 LCD User Instructions amp LED User Instructions GARDTEC 872 Contents User Information Using LCD Keypads I trod cti N 2512150 Mr ner Nell User Code Types Duress Cod Lunner e Setting The Systemi siisii anes Setting amp Unsetting via a Keyswitch assesseer Unsetting The System rsnrrnnrnvvnnnvvvnnrnnrrerrrvvnrevsvnerenen Part Setting The System Area Settings Mi dant nana REMOVING Zones rss etaient Testing The System Viewing The Event Log Changing The Chime Status Programming User Codes W W Wu Wu u uw dsseseeeerer renen renen nn kreere Programming Time amp Date cscceeeeeeceeeeeeeteeeeees User Initiating Remote Access Resetting After An Alarm c ecceeeeeeeeeeeeeeeeeeaees Using LED Keypads Setting The System mrrrronnrvnnnnnrnnrnrnnnnnannnrrnnnnnnrnnnen Unsetting The System rsnrrnnrnvrnnnvvvnnrnnrrerrnvrnnevsrnnrenen Part Setting The System Area Setting ua tahini ei REMOVING ZONES seiniin at etes aksen tes Testing The System Viewing The Event Log Changing The Chime Status Programming User Codes mrsvvrnnnnvvnnnnnrrvvrnvrnvsvrrnnrsnnn User Initiating Remote Access Resetting After An Alarm 0 c cccceeeeeeereeeeeeeeeeaees LED Display Glossary System Afttributes t brka ke LDER Service Recorder
2. At the end of the exit time either the exit tone will stop or a single beep will be emitted dependant on system settings Part Setting System using Area 1 2 or 3 codes With the display showing Un Enter an Area code 1 2 3 4 5 6 7 The exit tone will sound and the display will show EZ Press NO then 1 2 or 3 for Part 1 2 or 3 The bars on the display will change to The two bottom bars if Part 1 has been selected E The top and bottom bars if Part 2 has been selected E The bottom bar only if Part 3 has been selected E The exit tone may or may not be heard dependant on the system settings Exit the premises or retire to an unprotected part of the system At the end of the exit time either the exit tone will stop or a single beep will be emitted dependant on system settings Page 22 GARDTEC 872 User Manual Area Setting using Master or Global Main codes 1 With the display showing Lin Enter a Master or global Main code 2 The display will show GE flashing Press YES to start setting the system the exit tone will sound 3 To turn Area 1 Off press YES 1 and or To turn Area 2 Off press YES 2 and or To turn Area 3 Off press YES 3 and or To turn Area 4 Off press YES 4 and or To turn Area 5 Off press YES 5 and or To turn Area 6 Off press YES 6 and or To turn Area 7 Off press YES 7 and or To turn the Cleaner Area Off press YES 0 4 Exit the premises or retire to an unp
3. GARDTEC 872 lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Do you want to Set STUART Do you want to Change Chime GARDTEC 872 4 Press YES the display will show for example Or Press NO to change the status of the Chime then press YES the display will show Press 0 to escape the display will show Page 13 User Manual Chime is Off ok Chime is On ok Do you want to Change Chime lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 User Manual GARDTEC 872 Programming User Codes Master code only The charts on pages 2 amp 35 should be completed by the engineer user for future reference of what codes have been allocated on your system Under no circumstances should the actual user code be written down If your installation company has given you keyswitches for the operation of your system the last five user codes may have been reserved for use by these keyswitches If your engineer has indicated see pages 2 amp 35 that some of the user numbers on your system have been reserved you should not use them whilst programming user codes If you do so your system may be adversely affected 1 With the display showing lt lt lt l
4. have finished viewing the Log press 0 twice to return to the Unset condition A complete list of possible LED displays is given in the section LED Display Glossary Page 25 User Manual GARDTEC 872 Changing The Chime Status Master code only The Chime zones will have previously been programmed by your installation company A Master level code may change the status of the chime between On and Off To do so proceed as follows 1 With the display showing Lin enter a Master code The display will show 5 E flashing Press NO four times the display will show Ch Press YES the display will show For an Press NO to change the Chime status When you have finished press 0 twice to return to the Unset condition Programming User Codes User Codes may only be programmed via an LCD keypad Page 26 GARDTEC 875 User Manual Programming Date amp Time Date amp Time may only be programmed via an LCD keypad User Initiating Remote Access Users should only initiate Remote Access when instructed to do so by the installation company 1 With the display showing Li mi enter a master level code then press NO seven times the display will flash r 2 Press YES the display will show Lu Wait then di Dialling then Ln Connected 3 When the installation company has finished the display will return to in In the event of an error the display will show Er you should try again Page 27 User Manual GARDTEC 872 Reset
5. is full setting The system is fully set The system is part 1 setting The system is part 1 set The system is part 2 setting The system is part 2 set The system is part 3 setting The system is part 3 set The system is cleaner setting The system is cleaner set An alarm has occurred press NO to view Fuse blown or battery volts low Control box tamper bell box tamper Expander1 tamper may show 1 to 16 Telephone Line fault or coms fail Power Cut EY Ac SE FE EI nm En En Page 29 User Manual Tamper keypad 4 may show 1 to 4 Reset is required by a higher level code or an error has occurred whilst programming Reset by Anti Code is required flashing Do you want to Set Remove zones Test system Change Chime Program User codes Program date time Log Waiting for numeric input Wait system in use Engineer code reset required flashing Call Engineer User Manual Displays Whilst Viewing Log LE Please be aware not all Log Events can be viewed on an LED keypad We rL recommend the use of an LCD keypad m ud Alarm occurred because of zone 4 was activated om ud Alarm occurred because of tamper on zone 4 ou flashing zone 4 was removed ir Telephone Line restored Pr Power restored d Duress code by user 3 TE Watchdog reset AT Alarm was reset bo bells on Gi User code 1 used may show 1 to 47 Fe Fire activated from alert keys on k
6. reset the system Or Can t Set Use ENGNR Code Call the installation company Or Can t Set Use ENG Anti Code 1234 Call the installation company and quote the number given Or Can t Set Use Anti Code 1234 Call the installation company and quote the number given Or Page 19 User Manual GARDTEC 872 4 To reset the system with an anti Code contact the central station or engineer as instructed by the installation company and quote the source given by the display The central station or engineer will give a return Anti Code this may contain the YES amp NO keys for example 5 YES 2 4 Enter this Anti Code into the keypad The system is now reset Page 20 GARDTEC 872 User Manual Using LED Keypads This section is dedicated to using LED keypads Twin Seven Segment Setting The System 1 2 Note Note With the display showing Un Enter the User Code followed by YES if Master or Main type code has been used The display will show E and the exit tone will sound Exit the premises via the authorised exit route the exit tone will change if any detectors are violated during exit Once the premises are secure listen that the exit tone returns to the continuous tone Wait until the exit tone finishes before leaving Setting the system with an area code will set only the area associated with that code Setti
7. the premises or retire to an unprotected part of the system At the end of the exit time either the exit sounder will stop or a single beep will be emitted dependant on system settings Page 7 User Manual GARDTEC 872 Area Setting using Master or global Main codes Areas will need to have been set up by the installation company lt lt lt lt UN SET gt gt gt gt 1 With the display showing 01 JAN 18 58 01 2 Enter a Master or global Main code the display will show for example Do you want to Set ELIZABETH 3 Press YES to start setting the system the exit tone will sound and the display EXITNow 123C will show All Zones ON 30 4 To turn Area 1 Off press YES 1 and or To turn Area 2 Off press YES 2 and or To turn Area 3 Off press YES 3 and or To turn Area 4 Off press YES 3 and or To turn Area 5 Off press YES 3 and or To turn Area 6 Off press YES 3 and or To turn Area 7 Off press YES 3 and or To turn the Cleaner Area Off press YES 0 As areas are turned off they will be removed from the display 5 Exit the premises or retire to an un protected area as detectors are violated the continuous exit tone will change Note Areas must first be programmed by the installation company before they will appear on the display Area Setting using Area codes Area codes are only effective to their own area with the excepti
8. eypad 2 Ac Alert activated from alert keys on keypad 2 Pe Panic activated from alert keys on keypad 2 Page 30 GARDTEC 872 A zone on test has failed read Log GARDTEC 872 User Manual System Attributes Zone No Zone Type Descriptor Part Info Example Front Door A1 Pt2 Page 31 User Manual GARDTEC 872 GARDTEC 872 User Manual User Manual GARDTEC 872 171 172 173 174 175 176 177 178 Service Record Date Comments Signature Alarm Reset Type Tamper Reset Type Page 34 GARDTEC 872 User Manual User Chart Please use this chart to indicate what user names have been programmed onto your system and those that are in use Page 35 User Manual GARDTEC 872 User 76 User 77 User 78 User 79 User 80 User 81 User 82 User 83 User 84 User 85 User 86 User 87 User 88 User 89 User 90 User 91 User 92 User 93 User 94 User 95 User 96 User 97 User 98 User 99 Page 36 GARDTEC 872 User Manual ACE User Instructions ACE Advanced Control Equipment allows control of your Gardtec 872 system via Infra Red Remote control Ace is available built in to a range of keypads or as a stand alone unit control is via neat remote keyfob s We strongly advise that User Number 1 is not used for ACE in order that the user retains control of the programming functions Setting the System with ACE 1 Point the keyfob at the ACE receiver and press the button 2 When the exit tone so
9. gt gt gt 2 With the display showing Gi ANa oee Ol 3 Enter a Master Code the display will show for example Do you want to Set STUART 4 Press NO seven times the display will show Do you want to Access Remote 5 Press YES the display will show Until Dialling commences En Then Please WAIT Dialling Until Connection Then Please WAIT Connect 6 When your installation company has finished the display will show lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Note In the event of any errors the display will show I ERROR Try Again Page 18 GARDTEC 872 User Manual Resetting After an Alarm Your installation company will have programmed the reset modes for your system so that it complies to your insurance company and legislation requirements Your installation company will have informed you as to the type of reset that your system is set for Before attempting to reset your system ensure that the system is Un set 1 If the system is programmed for any code reset enter a user followed by YES if Master or Main code is used the exit tone will sound and the display will show for example EXIT Now 123C All Zones ON 15 2 Enter the code again to abort the setting 3 The system is now reset Or If a higher level of code is required one of the following displays will be shown Can t Set Use Master Code Use a Master code to
10. layout shown below for the allocation of characters STU VWX YZ 0 9 User Manual GARDTEC 872 11 Referring to the character map enter the required character pressing the 3 key will display G pressing it again will show H and again will show I once the correct character is displayed press YES and the display will move on to the next position 12 Continue entering characters up to 9 If you require a blank space press YES while the is displayed to show the space this will not be displayed after programming is completed 13 As you press YES for the ninth character or if you have jumped from step 9 the display will change to Do you want to Prog USER CODES 14 If you wish to program other User Codes return to step 4 Or Press 0 to return to lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Page 16 GARDTEC 872 Programming Time amp Date 1 10 11 With the display showing Enter a Master Code the display will show Press NO six times the display will show Press YES the display will show For UK use press Yes The display will show Press No The display will show Enter the last two digits of the year e g 03 ifthe year is 2003 then Yes The display will show Press Yes Display will show Enter the Day and Month e g 11 09 for the 11th September then press Yes The display will show Ente
11. leaving Note Setting the system with an area code will set only the area associated with that code Note Setting an unset system with a cleaner code will set the full system Setting amp Unsetting the System via a Keyswitch One of two types of keyswitch es may have been fitted to your system Normal To set the system with a normal keyswitch insert the key and turn to the ON position then remove the key To unset insert the key and turn to the OFF position Biased To set the system with a biased keyswitch insert the key and turn it then return the key to the original position and remove To unset repeat this operation Page 5 User Manual GARDTEC 872 Unsetting The System 1 Note Note Note Note Enter the premises via the authorised entry route the broken entry tone will sound proceed to the keypad At the keypad enter a valid code the display will show lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 The system is now unset If an Area Code has been entered only the area associated with that code will be unset If a Cleaner Code has been entered only the cleaner area will be unset For DD243 systems ACE keyfobs may have to be used to unset the system chexk with your installation company In the event of the system being set using ACE when the battery is low the display will show ACE Battery Low when the system is unset press Yes to clear the display a
12. ln eders User Charta ise aser enn nr hd ACE Instructions nine Programming ACE Keyfobs onto your System Page 1 OO OO O1 AR WWW oO 11 12 12 13 14 16 17 18 19 20 21 21 21 22 23 23 24 24 25 26 26 27 28 29 30 31 34 34 35 36 37 38 User Manual User Manual GARDTEC 800 Series User Information Control Panel Model No of Keypads Keypad 1 Location Type Type Type Type Type Type Type ACE Mode if fitted Normal Security High Security Keyswitch 1 Location Reserved User Code User No Keyswitch 2 Location Reserved User Code User No Keyswitch 3 Location Reserved User Code User No Keyswitch 4 Location Reserved User Code User No Keyswitch 5 Location Reserved User Code User No Keyswitch 6 Location Reserved User Code User No Keyswitch 7 Location Reserved User Code User No Keyswitch 8 Location Reserved User Code User No Installation Company Name Installation Company Address Note Please ensure this section is completed by the installation engineer Page 2 GARDTEC 800 Series User Manual Introduction The Gardtec 872 control panel is a multi zone microprocessor controlled unit Two types of display are available for the system keypads a LCD offering a 32 character display with zone descriptors and user names or b Twin seven segment LED displays offering limited control user programming options The LED type displays normally used for setting and unsetti
13. nd change the battery in the keyfob Part Setting The System using Master amp Main type codes Note lt lt lt lt UN SET gt gt gt gt With the display showing 01 JAN 18 58 01 Enter a Master or Main type code the Do you want to display will show for example Set STUART Press 1 2 or 3 for Part 1 2 or 3 the 7 display will show for example BAIT NOM 280 Part 1 15 If a Global code Master or Main has been used all areas that are being set will be Part 1 set Note If an Area Main code has been used only Part 1 set for that associated area will occur Page 6 GARDTEC 872 User Manual 4 The exit tone may or may not be heard dependant on the system settings Exit the premises or retire to an unprotected part of the system At the end of the exit time either the exit sounder will stop or a single beep will be emitted dependant on system settings Part Setting System using Area 1 to 7 codes 1 With the display showing 22 Dev SET RS Sis 01 JAN 18 58 01 Enter an Area Code 1to 7 the exit tone will sound and the display will show for example EXIT Now 1 All Zones ON 15 Press NO then 1 2 3 for the Part Set you require the display will show for example EXIT Now 4 Part 1 20 The exit sounders may or may not go silent this will depend on the system settings Exit
14. ng an unset system with a cleaner code will set the full system Unsetting The System 1 Note Note Note Enter the premises via the authorised entry route the broken entry tone will sound Proceed to the keypad enter a valid user code the display will show Un The system is now Unset If an area code has been entered only the area associated with that code will be Unset If a cleaner code has been entered only the cleaner area will be Unset In the event of the system being set using ACE when the battery is low the display will show b when the system is unset press Yes to clear the display and change the battery in the keyfob Page 21 User Manual GARDTEC 872 Part Setting The System using Master amp Main type codes 1 2 Note Note With the display showing Lin Enter a Master or Main type code The display will show GE flashing Press 1 2 or 3 for Part 1 2 or 3 the display will show the E and The two bottom bars if Part 1 has been selected E The top and bottom bars if Part 2 has been selected E Z The bottom bar only if Part 3 has been selected E If a Global code Master or Main has been used all areas that are being set would be Part Set If an Area Main code has been used only the Part Set associated with that area would be Part Set The exit tone may or may not be heard dependant on the system settings Exit the premises or retire to an unprotected part of the system
15. ng at secondary points Please take time to familiarise yourself with the type of equipment fitted to your premises as it will prove invaluable whilst using this manual User Code Types 99 user codes are available offering 19 code types with varying levels of access to the system User number 1 will always be a Master Level User but the remaining User Codes may be programmed by a Master Code to the required level of access These may be changed at any time via a Master level code The User Code levels available and the functions available for the levels are Master Allows Setting Unsetting Zone Remove if programmed by engineer Test System View Log Chime On Off User Codes Set Time Date Reset After Alarm if programmed by engineer Unsetting Cleaner Full System Setting from unset system Cleaner Area Unsetting from set system Cleaner Part Set from part cleaner set system Area 1 to 7 User Allows Area 1 to 7 Setting Area 1 to 7 Part Setting Area 1 to 7 Unsetting Main User Allows Setting Part Setting Zone Remove if programmed amp Main User 1 to 7 by engineer System Test Unsetting Reset after Alarm if programmed by engineer Main User 1 to 7 are specific to their area Control Used for control of other equipment see installation company for details Set Only Only Allows for the setting of the system Note For information on using Duress on the Gardtec 872 see Using Duress Section Page 3 Use
16. on of the cleaner area This may be turned off by an area code only if all areas are in the unset condition Use is the same as Setting the system shown on page 5 but only the relevant area will be set Page 8 GARDTEC 872 User Manual Removing Individual Zones Master amp Main codes only If programmed by the installation company individual zones may be removed this may only be done by a Master or Main level of code It should be noted that if an Area Main code is being used only zones associated with that area may be removed 1 2 Note lt lt lt lt UN SET gt gt gt gt With the display showing RE co Enter a Master or Main level code the display will show Do you want to Set STUART Press NO the display will show Do you want to REMOVE Zones Press YES the display will show Enter Zone No then YES or NO Enter the zone number you wish to remove followed by YES pressing NO will un remove a zone the display will show Enter Zone No then YES or NO Repeat step 5 until you have removed all the required zones Set STUART Press 0 to escape the display will show De You want tos Press YES the continuous exit tone will sound Exit the premises via the authorised exit route the exit tone will change as detectors are violated When the premises are secure lis
17. r Manual GARDTEC 872 Duress Codes Duress Codes may be programmed onto your GardTec 872 system When used a Duress code will appear to operate the security system in the normal way but will also send a PA personal attack signal to central station if programmed One of two types of Duress codes may be programmed onto your system a Add 1 to the first digit of any User Code e g the normal User Code is 5678 so the Duress code for this User would be 6678 If programmed to this type of Duress by the engineer the 1 digit increment will apply to all User Codes on the system b User 7 Duress Any code that is programmed as User number 7 will be the Duress code for that system Your installation company will advise you on the type of Duress codes that are programmed on your system and the correct use of those codes Page 4 GARDTEC 872 User Manual Setting The System 1 With the display showing lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 2 Enter the User code followed by YES if Master or Main type code has been used EXIT Now 123C The display will show for example All Zones ON 15 and a continuous exit tone will sound 3 Exit the premises via the authorised exit route the exit tone will change if any detectors are violated during exit 4 Once the premises are secure listen that the exit tone returns to the continuous tone 5 Wait until the exit tone finishes before
18. r the current Time using the 24Hr format e g 20 30 for 8 30pm then press Yes The display will show Press 0 the display will show Page 17 User Manual lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Do you want to Set STUART Do you want to Set DATE TIME Summer Adjust is On ok Year is 2000 ok Enter Year 20 Then YES Year is 2003 ok Enter Day Month Then YES Enter Hours Mins Then YES Do you want to Set Time Date lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 User Manual GARDTEC 872 User Initiating Remote Access Optional Access Remote allows your installation company to examine your system and re program system settings as you need the changes without the need for an engineer to visit your premises If your system has remote communications fitted your installation company may have programmed the system so that you initialise the Access Remote call usually on lines with incoming calls barred To initiate the Remote Call follow the instructions below 1 Negotiate with your installation company when you should initiate the Remote Call A 3 i f lt lt lt lt UN SET gt
19. rotected part of the system At the end of the exit time the exit tone will stop provided the system was clear Note Areas must first be programmed by the installation company Area Setting using Area codes Area codes are only effective to their own area with the exception of the cleaner area which may be turned off by an area code only if all areas are in the unset condition Removing Zones Master amp Main codes only If programmed by the installation company individual zones may be removed this may only be done by a Master or Main level of code It should be noted that if an Area Main code is being used only zones associated with that area may be removed 1 With the display showing Lin Enter a Master or Main level code 2 The display will show 5 E flashing press NO 3 The Display will show I E flashing press YES 4 The display will show I 5 Enter the zone number you wish to remove followed by YES Page 23 User Manual GARDTEC 872 Note The display will show I If you wish to remove other zones return to step 5 Or To escape press 0 the display will show GE flashing Press YES to start setting the system Exit the premises or retire to an unprotected part of the system At the end of the exit time the exit tone will stop provided the system was clear Zone remove is only effective for the one set Testing The System Master amp Main codes only 1 With the display showing Lin En
20. t UN SET gt gt gt gt 01 JAN 18 58 01 2 Enter a Master Code the display will show Do you want to Set STUART 3 Press NO five times the display will show DOVRE Prog USER CODES 4 Press YES the display will show Enter User No 1 99 Then YES 5 Enter the user number 1 to 99 that you wish to program followed by YES the Now Enter cois i display will show Then YES At this point the display may ask if this code is for ACE Keyfob dependant on the system settings Press Yes or No as required if this question is asked Page 14 GARDTEC 872 User Manual 6 Enter the code you require codes may be 4 5 or 6 digits followed by YES Entering 000000 will delete an existing code Note If the code already exists or is a duress of another code an error will be shown choose another code and return to step 6 7 The display will show Code Type not if user 1 is being programmed Master ok 8 Press No until the level of code you require is displayed then press Yes The display will show for example User 02 Name USER 02 9 If you wish to accept the name shown press YES and jump to step 13 Or If you wish to change the name shown press NO the display will show User 1 Name gt 10 You may now enter up to nine characters for the user name using the
21. ten that the exit tone returns to the continuous tone Wait until the exit tone finishes before leaving Zone remove is only effective for the one set Page 9 User Manual GARDTEC 872 Testing The System Master amp Main codes only 1 With the display showing Sis SS UN SET 225 01 JAN 18 58 01 2 Enter a Master or Main level code the display will show Bo YOU MERI Set STUART 3 Press NO the display will show palvouwanttor REMOVE Zones 4 Press NO the display will show Do you want to TEST the System 5 Press YES the display will show Test ALL Areas 6 Press YES to test the full system or NO until the area you wish to test is shown 7 Press YES the display will show 1 Status 4 Strobe for 3 seconds 6 Sounder 9 Bell Then for example lt All Zones OK gt TESTING 8 Pressing 1 will enter zone Status mode All zones will show on the display and will be deleted as each zone is triggered Press 0 to escape Pressing 6 will silence the internal sounder Pressing 4 will toggle the Strobe On Off Pressing 9 will toggle the Bell On Off Page 10 GARDTEC 872 9 10 Whilst in Test mode any zones violated will sound the internal sounder if it has not been silenced and show on the display When you have finished testing the system press 0 twice the display will sho
22. ter a Master or Main level code the display will show SE flashing Press NO twice the display will show FE flashing Press YES the display will show HR press YES if you wish to test all areas or press NO until the area you wish to test is displayed then press YES The display will show FRA if all zones are clear Whilst in test mode Pressing 6 will silence the internal sounders Pressing 4 will toggle the strobe On Off Pressing 9 will toggle the Bells On Off When you have finished testing the system press 0 twice to return to the Unset condition Page 24 GARDTEC 872 User Manual Viewing The Event Log Master code only To get the full capability from the Log we recommend using an LCD keypad 1 Note With the display showing Lin enter a Master code The display will show GE flashing press NO three times The display will show La flashing Press YES the display may show for example L this is the most recent event If you have a printer connected pressing 1 will toggle the printer On Off Whilst viewing the Log Pressing NO will move back to the previous event Pressing YES will move forwards to the next event Pressing 7 will take you back to the first event of the previous day Pressing 9 will take you forwards to the first event of the next day Pressing 3 will display the Date Time in the format Day of month two digits Month two digits Hour two digits Seconds two digits When you
23. ting After An Alarm Your installation company will have programmed the reset modes for your system so that it complies to your insurance company and legislation requirements Your installation company will have informed you as to the type of reset that your system is set for Before attempting to reset your system ensure that the system is Un set 1 If the system is programmed for any code reset enter a user followed by YES if Master or Main code is used the exit tone will sound and the display will show for example EZ 2 Enter the code again to abort the setting 3 The system is now reset Or If the display shows E r when you attempt to reset it refer to the programmed reset mode and take the appropriate action as follows Reset Type Action Master Code Use a Master code to set and abort setting Engineer Code Call the installation company Engineer Anti Code Call the installation company Anti Code When you try to set the system make a note of the four digit number given on the display call the installation company or central station for an Anti Code and proceed as shown from step 4 4 To reset the system with an Anti Code enter the number given by the central station or installation company into the keypad this may contain the YES amp NO keys 5 The system is now reset Page 28 GARDTEC 872 LED Display Glossary Displays During Normal Use CI 2 mi vag mm ve Pe System Unset The system
24. unds exit the premises in the usual way Part Setting the System with ACE 1 Point the keyfob at the ACE receiver and press the button 2 When you hear the exit tone press the keyfob button again within 3 seconds for Part Set 1 or Press 1 2 or 3 on the receiver keypad for the Part Set you require Unsetting the System with ACE 1 Enter the premises via an authorised entry point 2 Point the keyfob at the receiver and press the button Page 37 User Manual GARDTEC 872 Programming ACE Keyfobs onto your System Two modes are available for ACE these are Normal amp High Security Please check the User Information Chart on page 2 noting the mode of your ACE control Normal Security In this mode up to fourteen keyfobs may be programmed onto a single user number 1 Follow the procedure for programming user codes to the point when the user code is entered 2 Point the keyfob at the ACE unit and press the button on the fob 3 Repeat this procedure for any other fobs you wish to be programmed using the same user number each time e g User 1 or User 2 etc each time 4 If more than one ACE receiver is fitted fobs need to be programmed onto all ACE receivers yet again the same user number should be used Note When programming the fob onto more than one receiver on the same system the button on the fob MUST be held down continuously between programming onto the first and subsequent ACE receivers High Securit
25. w Viewing The Event Log Master code only 1 With the display showing Enter a Master Code the display will show for example Press NO three times the display will show Press YES the display will show for 3 seconds Then for example Page 11 User Manual lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Do you want to Set STUART Do you want to View the LOG While Viewing 1 Printer On Off Read Log 01 JAN 18 58 01 User Manual 5 This is the most recent event in the log Whilst viewing the Log Pressing NO will move back to the previous event Pressing YES will move forward to the next event Pressing 7 will take you to back to the last event of the previous day Pressing 9 will take you forward to the first event of the next day When you have finished viewing the Log press 0 twice the display will show Changing The Chime Status Master code only The Chime zones will have previously been programmed by the installation company A Master level code may change the status of the Chime between On and Off To do so proceed as follows 1 With the display showing Enter a Master Code the display will show for example Press NO four times the display will show Page 12
26. y In this mode each keyfob will occupy a User number The number of keyfobs that may be used is limited by the maximum number of user codes available on the system up to a maximum of fourteen 1 Follow the procedure for programming user codes to the point when the user code is entered 2 Point the keyfob at the ACE unit and press the button on the fob 3 Repeat this procedure for any other fobs you wish to be programmed using a different user number each time e g User 1 or User 2 etc each time 4 If more than one ACE receiver is fitted fobs need to be programmed onto all ACE receivers retaining the same user number for each individual fob Note When programming the fob onto more than one receiver on the same system the button on the fob MUST be held down continuously between programming onto the first and other ACE receivers Note In all cases when the ACE is used only Master amp Main user levels will allow part setting via the keyfob Other code levels will only allow part setting in conjunction with the keypad Page 38 GardTec Ltd Internet http www gardtec ltd uk e mail sales gardtec ltd uk en gt Aa EE x D D 24 UKAS QUALITY British Security Industry Association MA AGEMENT 001 PR5407 Rev1 0