Pyronix Octagon User Guide
Contents
1. OCTAGON USER INSTRUCTIONS E OCTAGON SUPPLY TAMPER Ea M v 0 Da ae 0 amp 9 9 9 0O00 PYRONIX LIMITED MAY 1997 Ww his product is approved for use in the C C Residential Commercial and Light Industrial Environment FOR UK AND EXPORT USE RDOC 289 A ISSUE 7 Pyronix Limited Pyronix House Braithwell Way Hellaby Rotherham S66 8QY ENGLAND Tel 44 0 1709 700100 Fax 44 0 1709 533429 Technical help line UK only 0900 8037 800 This is a premium rate line where calls are charged at 50p per minute email uk sales Q pyronix com export sales Q pyronix com marketing pyronix com technical support pyronix com website www pyronix com CONTENTS 8 INTRODUCTION ACCESS LEVELS FEATURES FUNCTIONAL DESCRIPTION Operating Modes 4 2 Entry Exit Mode ZONES Engineer Programmable Zones 24 Hour Zones CONTROLS AND FUNCTIONS USING THE OCTAGON AFTER PROGRAMMING Cleaner functions Full Setting The Panel Part Setting The Panel Unsetting The Panel Activating The Personal Attack PA Alarm Turning Chime On And Off Limited User Functions User 2 Cleaner functions Deactivating Cleaner Zon
2. If the zone does not clear and the warning tone continues the faulty zone can be omitted If this is not done the system Will not set To omit a zone enter any user code 4 00 X Q0 followed by A CA for part set A A for part set B RDOC289D 7 7 dii A C for part set C as required During the exit period enter E D The display will clear and a rapid tone will be produced Now enter the numbers of any zones which need to be omitted Zone 9 will omit the remote RKP zone Note All remote keypad zones wil be omitted by entering number 9 The control panel will acknowledge these by displaying the zone number s selected Now enter to allow the exit period to continue 7 2 4 Changing Limited User Code In day mode enter E 5 followed by the existing Limited user code 3 00 X Q0 The keypad will bleep to acknowledge that this code is correct Then enter the new Limited user code twice After each input the keypad will give an acknowledgement bleep If a code is not entered correctly the keypad will give an error tone and return to day mode 7 3 Master User Functions USER 1 The master user has access to all the Limited user and cleaner functions as well as those listed below 7 3 1 Changing Cleaner Code In day mode enter 4 followed by the Master user code ao X X 00 The keypad will bleep to acknowledge that the code is correct Then enter the new Cleaner code twice After each input the keypad will
3. bleep If the code is not entered correctly the keypad will emit an error tone and return to day mode 7 3 2 Changing Limited User Code ae In day mode enter 5 followed by the Master user code Then enter the new Limited user code twice 7 3 3 Changing Master User code In day mode enter A 6 followed by the Master user code Then enter the new Master user code twice 7 4 System Test Mode This function performs a number of system tests which are listed below In day mode enter E 7 S P dd The unset display will now flash a Now enter user code ao 4 00 00 EN Lie All display LEDs on the keypad will all turn on and the number display will show a flashing TA E TE Now press 7 The strobe output will be activated press T The strobe output will turn off and the bell output will switch on press T The bell output will turn off and any extension speakers fitted will sound press 7 The extension speakers will turn off and the panel will return to day mode 7 4 1 Walk Test To verify the operation of all detectors in the alarm system a user walk test feature has been included To perform a walk test enter 8 x 8 V The unset display will now flash p Li 7 Now enter the Master user code X 00 00 Q0 If any zones are active a high tone will be generated from the keypad and the zone numbers will be displayed on the Keypad If all zones are inactive then a low tone will be heard Enter
4. panel the tamper LED flashes and the tamper tone is emitted there is no battery low battery or there is a power failure If option 48 49 is set to O default M S S lt 5 Sy ww Le ES S e Forthe following conditions the activation indicated will cause a continuous tone to be heard Enter any user code once to display the system status Enter the user code a second time to return to Day Mode all tamper circuits must be closed before the system can return to Day Mode RDOC289G Issue 7 13 14 16 14 18 19 20 2 Tamper alarm call Engineer Intruder alarm The LED display shows the number of the zone activated Enter any user code to reset the panel OCTAGON SUPPLY TAMPER s SUPPLY 0 TAMPER SUPPLY 04 TAMPER OCTAGON SUPPLY 0 TAMPER wrm Fire Alarm Enter any user code to reset the panel The LED display shows the number of the zone activated Engineer code is required to reset the panel The LED display shows the number of the zone activated SUPPLY 0 TAMPER SUPPLY 0 TAMPER 11 USER QUICK REFERENCE GUIDE RDOC289H Issue 7
5. AM PER SUPPLY TAM PER SUPPLY PER OCTAGON 0 SUPPLY or LI 10 Td 12 13 14 sequence A number indicates a zone activation OCTAGON O SUPPLY TAMPER OCTAGON SUPPLY TAMPER n 9 mna y O e g zone 6 Followed by number shows an Engineer walk test activation SUPPLY 04 TAMPER e g zone 8 SUPPLY 0 TAMPER e g zone 7 SUPPLY TAMPER SUPPLY TAMPER C followed by a number shows a user omitted zone e g zone 4 was omitted here during the setting RDOC289F Issue 7 11 8 RKP LED FUNCTIONS Supply LED Tamper LED Tamper LED flashing minutes Line Fail LED 8 1 RKP Il LED Functions All of the above functions including the following Fire LED P A LED Intruder LED Engineer LED required to reset the Chime LED 9 CLEANING Indicates a mains and or battery supply Indicates a tamper fault Indicates a keypad lockout for 3 5 Indicates a communicator line fault Indicates a fire alarm Indicates a personal attack alarm Indicates a zone activation When illuminated the engineer code is panel Indicates that the chime function is on DO NOT use strong detergents to clean this control panel To remove any dirt orgrime wipe with a clean damp cloth ONLY 10 TROUBLESHOOTING The following guide shows the most
6. Engineer code gives total access to the system programming during day mode 2 ACCESS LEVELS Master User user 1 enables Limited User user 2 enables 1 Chime programming 1 Panel setting and unsetting with a unique pass code 2 Alteration of all access codes except engineers 2 Changing user code 2 3 Test mode 3 Omitting zones 4 All user code 2 facilities 4 Setting and unsetting of the door chime facility Cleaner level enables Engineer level enables 1 Panel setting and unsetting with a unique pass code 1 Changing engineers code 2 All system programming 3 Panel setting and unsetting providing the panel is in day mode 3 FEATURES 2 User Level Codes cleaner code and engineers code all programmable Fast set facility 8 Programmable alarm zones 8 Zone Tampers 4 Full set Part set configurations Personal Attack alarm zone 16 key backlit keypad 3 LEDs and LED display on RKP for immediate indication of panel status Walk Test facility System Test Function Extension speaker volume control with alarm override Separate Bell and Strobe outputs Zone omit facility on exit Part sets programmable as silent time or instant Digital Communicator outputs Optional communicator delay activation polarity Customer engineer reset Two individual keyswitch inputs Soak zones Fire zones and 24hour zones Non omitable zones Up to four remote keypads Additional zone on each keypad Duress code 100 event memo
7. alk test the alarm zones tamper zones and personal attack zone activations will be recorded in the event log Event log The Octagon panel incorporates a memory log of the last 100 events and is accessible in master user mode It will record panelsetting personal attack alarms and will show which tamper and alarm zones have been triggered Soak zones user omitted zones and zones activated by the engineer walk test will also be displayed The event log may be cleared by the User if he is permitted to do so by the engineer All zone activations after an alarm event are recorded in the log Keyswitch inputs Two Keyswitch inputs are available and these may be usedforfull setting and part setting the system 7 USING THE OCTAGON AFTER PROGRAMMING 7 1 Cleaner Functions 7 1 1 Full Setting The Panel To full set the system enter the cleaner code ao X X X The full set symbol F will be displayed until the panel sets 7 1 2 Part Setting the Panel To part set the system enter the cleaner code X X 00 00 followed by CA for part set A A for part set B A C for part set C MOR L will be displayed until the panel sets A part set symbol 7 1 3 Unsetting The Panel To unset the system enter the cleaner code The keypad display will show LI which indicates that the system is not completely unset Any cleaner zones which are activated at this time will create a full alarm 7 1 4 Activating Personal At
8. common displays given by the Octagon remote keypad If an incorrect function code is entered and it is not known what input the control panel is expecting next please wait The control panel will only wait for approximately 1 minute before reverting back to either day mode or Engineer mode If this does not work press A then wait again 1 Panel unset Day Mode RKP LED display layout 2 Full set indication 3 Part set A 4 Part set B 5 Part set C 6 Panel set amp x lt e f ke S e RKP LED display layout OCTAGON SUPPLY TAMPER x O OCTAGON SUPPLY TAMPER O O OCTAGON SUPPLY TAMPER O O 12 10 11 12 13 14 15 Programmable functions returned to factory settings call Engineer OCTAGON amp c amp SUPPLY 6 e S e TAMPER O E O Sy y Sy S wi Mains Failure in Day Mode providing system is battery backed a tone will be emitted A P and the tamper LED will flash for a second when arming the system OCTAGON A SUPPLY TAMPER Q T e OCTAGON s SUPPLY TAMPER O SUPPLY No Battery Low Battery Power Fail When trying to arm the
9. es Omitting Zones Changing Limited User Code Master User User 1 Changing Cleaner Code Changing Limited User Code Changing Master User Code System Test Mode Walk Test Chime Programming Engineer Code Arming Cancelling A Power Failure Duress Code Event Log LED FUNCTIONS 8 1 RKP II LED Functions 9 10 11 CLEANING TROUBLE SHOOTING QUICK REFERENCE GUIDE USER FUNCTIONS RDOC289B Issue 7 I WO WO O O O O O O O 00 0000000000000 410 Oo Oo C1 0101 I FA 1 INTRODUCTION The Octagon is a full featured intruder alarm control panel based around a microprocessor with 8 fully programmable zones and 2 dedicated 24 hour zones Personal Attack alarm and a System Tamper alarm It is operated via a 16 key remote keypad and has an arrangement of 3 LEDs and LED display to show the status of the system All features are fully programmable and there are three levels of access to the system Master User user 1 factory default 1 2 3 4 Limited User user 2 factory default 567 8 if enabled Cleaner Code factroy default 7890 if enabled Engineer factory default 9 9 9 9 The Master User code gives access to all settings and unsetting facilities and also allows the changing of code numbers and testing of the system The Limited User code gives access to the basic functions needed for everyday setting and unsetting the system The Cleaner code can only set and unset the panel in programmed areas The
10. mable for part set modes Non Omitable Zone This is a zone that is programmed by the engineer A zone programmed as a non omittable zone may not be omitted by the user This enables vital areas to be protected at all times Soak Zone A Soak zone is a zone which will not cause an alarm if triggered However the activation will be saved in the log Fire Zone If activated this will cause a pulsed bell and sounder activation in day or set modes The fire LED will illuminate on RKP Il 24 Hour Zone Will cause an instant alarm when the panel is in day or set modes Cleaner Zone Ifthe panel is disarmed using the cleaner code these zones will remain active and cause an alarm if violated Push to set A push to set zone will force the entry exit timer to terminate to prevent the user from having to wait for the entry exit period to finish RDOC289C Issue 7 5 5 2 24 Hour Zones Personal Attack Triggering of the Personal Attack P A zone will always cause a full alarm activation regardless of whether or not the panel is set If silent P A is programmed only the communicator will be activated The P A LED will illuminate on RKP II when the P A is activated Tamper If a tamper fault is present in day mode a high tone will be heard When a user code is entered the tamper LED will illuminate and the zone causing the tamper will be shown on the LED display If the tamper was caused by activation of the universal tamper zone then only the ta
11. mper LED will illuminate If a user code is not entered before the bell time expires the internal speaker and bell will turn off and the system will rearm Tamper If the panel has been set and a tamper fault occurs the system will go into full alarm condition When a user code is entered the tamper LED will illuminate and the zone violated will be displayed After the bell time has expired any further tamper faults will also cause alarm activation The strobe will remain on until the panel is unset A tamper alarm will also occur if the correct user code is not entered after three attempts Tamper Keypad If the code is not entered successfully after the third attempt the keypad will not accept anymore entries for 3 5 mins and a tamper will be generated The tamper LED will flash on the RKPII when the keypad is locked out EXPORT ONLY Tamper LED HesetThe tamper LED will remain on after a zone tamper or system tamper This can only be reset by entering engineer mode 6 CONTROLS AND FUNCTIONS Auto Rearm After an alarm the panel will automatically reset itself when the bell timer has expired Any zones which are still not clear after the bell time has expired will be omitted automatically Walk test The walk test function verifies that all the intruder detectors on the alarm system are functioning correctly When the walk test mode is enabled any activated zone will cause a chime and the LED display will indicate the relevant zone In engineer w
12. ry Push to set input Final door exit option 4 FUNCTIONAL DESCRIPTION 4 1 Operating modes Day Mode This is the state of the panel when unset not armed Personal Attack and Tamper inputs however remain active 24 hours a day These are referred to as 24 hour zones Day mode is identified by the U unset on the LED display oet Modes When the panel is set armed an activation of any Access Immediate or 24 hour zone will cause an alarm condition When an alarm is generated the internal and external sounders will operate for the length of time programmed The strobe will also be activated and will continue to operate after the bell time has expired until the panel is reset Fullset Partset At the time of setting the control panel any one of four set modes can be selected i e Full set Whole sys tem armed nobody on premises Part set A All Part sets may be Part set B configured as fast set Part set C timed exit or night set 4 2 Entry Exit modes Entry When the panelis set and an entry zone is triggered the entry timer will begin to count down During this period an entry tone single repeated bleep will be produced by the internal sounder The tone will change to a dual repeated bleep when half the entry time has been reached two ply Any zones which are programmed as Access zones will be ignored If the user code is entered before the end of the count down period the panel will return to day mode If the timer is allo
13. tack PA Alarm To activate the PA alarm enter z or X 7 1 5 Turning Chime ON and OFF With the panel in day mode enter 3 D l As this feature is turned on a two tone chime will be given by the remote keypads and any extension speakers if fitted the chime LED will illuminate on the RKP Il With chime enabled any zones programmed to chime by the Master user will cause the same two tone chime to be given by the remote keypads and speakers The chime zone number will also be displayed on the RKP A chime caused by a RKP remote zone will be displayed as To turn off the chime facility enter D 7 2 LIMITED USER FUNCTIONS user 2 7 2 1 Cleaner Functions The limited user has access to all the cleaner functions as well as those listed below The Octagon control panel has to be in day mode for these additional features to be accessed 7 2 2 Deactivating Cleaner Zones If the control panel has been reset using the cleaner code the cleaner zones will still be active If the limited user code is entered the display will change from LI and all cleaner zones will be deactivated The Cleaner cannot reset the panel if there has been an alarm activation 7 2 3 Omitting Zones If one or more immediate zones are triggered whilst in exit mode a warning tone will be produced and the zone number will be displayed If the zone clears the warning tone will change to an exit tone and the full set part set indicator will be displayed
14. the panel has previously been reset by the Master User Code V To arm panel enter A cy The unset display will now flash Now enter the Engineer code ao 00 X 00 The panel will now arm Enter X A oO or x To par set the panel 7 5 Cancelling A Power Failure In day mode if the mains supply is interrupted the tamper LED and P will flash and a tone will be generated by the remote keypad To cancel this tamper alarm enter any user code 7 6 Duress Code If the last two digits of a user code are reversed when arming or disarming the panel the digital communicator personal attack output is activated The correct code must be entered to reset the PA communicator output e g Master code 20304 Duress code 1 3 a RDOC289E Issue 7 9 7 7 N The Master User may view the event log To view the event log enter 3 2 The unset display will now flash Pd Event Log Now enter the Master User code ao ao 00 00 the last zone activation will be displayed on the RKP Key 10 H to scroll backwards 0 to scroll forwards to clear log if enabled by engineer to exit to day mode 1 Indicates that the next event caused the alarm activation when the panel was in day mode RKP Il LED display layout RKP display layout SUPPLY TAM PER SUPPLY T
15. to end walk test Note Unlike the Engineer walk test the Master user walk test will not enter zone activations into the event log 7 4 2 Chime Programming In order to increase system flexibility the chime programming may be performed by the Master User Fourchime options are available on the Octagon control panel and these are Day mode Part set A Part set B Part set C In day mode any of the eight standard zones may be programmed to chime In addition to this when the system is part set any omitted zones can also be programmed to chime This allows the chime to operate at any time except when the control panel is full set Chime is programmed as follows In day mode enter 3600 l ES i The keypad display will change to cy flashing to indicate that chime programming has been selected ie TUS Now enter the Master User code ao 00 00 00 the keypad will bleep to acknowledge that the code is correct Next enter for Day mode CA for Part set A for Part set B for Par set C The keypad will bleep to acknowledge a key press Now enter the numbers of the zones you wish to chime Pressing 0 will clear all chime zones and should be used if reprogramming is necessary When all zone numbers have been entered press x to return to day mode Programming of another mode to chime will require the above sequence to be repeated 7 4 3 Engineer Code Arming The engineer may arm and reset the panel from day mode if
16. wed to elapse before the user code is entered the panel will go into an alarm state In this case the system needs to be Unset then reset Exit With the panel in day mode if a user code is entered the exit timer will begin If all the Immediate zones are clear then the exit tone will be heard Leave the protected area by the predetermined exit route As you trigger access and entry exit zones the tone will change to a high tone When all the zones are clear the exit tone will continue again untilthe end of the time out period and the panel will arm If the exit time is reached before all access and entry exit zones are clear a warbling tone will be heard The panel will arm when the entry exit zone is clear 5 ZONES 5 1 Engineer Programming Zones Entry Exit This is a zone which allows limited time access to the premises in order to set or unset the system Access This is a zone which on setting the panel allows access to the Entry Exit zone However if the panel is set and an Access zone is triggered before an Entry Exit zone then an alarm will be generated immediately Immediate This is a zone which will create an immediate alarm when the panel is set Omitted If a zone is programmed as an Omitted zone by the Engineer then it is ignored by the panel Zone 9 omits the RKP remote zone ltalso allows the user to continue to use the alarm system even if a fault has been discovered on one or more zones Omitted zones are only program
Download Pdf Manuals
Related Search
Related Contents
じつは派遣より悲惨!? “ブラック化”する外食・小売 Philips Wall light 33067/17/86 取扱説明書・お料理ノート1(5.2MB) Presentación de PowerPoint OM, Partner, P51-450 SM, 96111001406, 2009 Whirlpool RM988PXS User's Manual Bauer Bedienungsanleitung_TX_Plus_D Gestor de electrodomésticos inalámbrico Modelo: ESM600 Lenovo ThinkPad E430c Copyright © All rights reserved.