DIGITAL MULTIMETER AX-101
Contents
1. relative humidity lt 75 Guaranteed for one year since production data DCV RANGE ACCURACY RESOLUTION 200mV 100uV 2V 0 5 4 1mV 20V 10mV 200V 100mV 600V 1 0 5 1V Input resistance 1M for all range ACV RANGE ACCURACY RESOLUTION 200v 1 2 10 100mV 600v 1V Input resistance 1 Frequency response 40 400Hz WWW AXIOMET EU RANGE ACCURACY RESOLUTION ZMA 1 5 3 TuA 200mA 100uA 2 0 5 TOMA Max input current 10A within 10 seconds Overload protection 0 2A 250V self resume fuse 10A 250V fast melt fuse RESISTANCE 0 RANGE ACCURACY RESOLUTION 200 Q 0 8 5 0 10 2k Q 10 20k Q 0 8 3 100 200k Q 100 Q 20M Q 1 0 15 200M 5 0 1 0 15 10k O Note For the range of 2000 short circuit test probes together to measure the resistance of the test leads and then subtract it from the real measurement result Diode and continuity testing RANGE DISPLAYING TESTING CONDITION Forward voltage drop of diode Forward DCA is approx 1mA the backward voltage is approx 3V eil Buzzer makes a long sound while resistance is less than 70 20 0 Open voltage is approx 3V Overload protection DC 250V or AC peak value Bartery test At 1 5V range overload inside is 150 working current is 100 At 9V range overload inside is 9000 working cur
2. battery as following steps when the icon C displays 1 Open the back cover 2 Replace a new battery with 9V An alkaline battery is recommended because of its good capacity 3 Fix back cover FUSE REPLACEMENT Please use the same size fuse as replacement The specifications are subject to change without notice The content of this manual is regarded as correct error or omits Pls contact with factory We hereby will not be responsible for the accident and damage caused by improper operation The function stated for this User Manual cannot be the reason of special usage MB 0203 01 III WWW AXIOMET EU
3. AXIO MIMET DIGITAL MULTIMETER AX 101 OPERATION MANUAL GENERAL The instrument is a pocket digital multimeter which be used to measurement DCV ACV DCA resistance diode and continuity test The instrument is an excellent ideal tool for labs household and wireless enthusiast SAFETY NOTES 1 Do not input a limited value when measuring ranges 2 Voltage less than 36V DC and 25V AC is a safety voltage When measuring voltage higher than DC 36V AC 25V check the connection and insulation of test leads to avoid electric shock 3 Be sure to keep the test leads off the testing point when converting function and range 4 Don t input the voltage value when measuring resistance SPECIFICATION 1 Displaying Max indication Sampling rate Over range indication Low battery indication Operation environment Store environment Power Measurement Weight Accessories 2 TECHNICAL DATA 22mm data height LCD display 1999 31 2 auto polarity indication approx 3 times sec MSD display 1 23 symbol displays 0 4 0 C relative humidity lt 80 10 50 C relative humidity lt 80 one 9V battery NEDA1604 6F22 or equivalent 140x65x40 mm lengthxwidthxheight approx 180g including a 9V battery operation manual gift box test lead and a 9V battery Accuracy a x reading d Surrounding 23 5 C
4. e under test is over 1 reading shall be stable a few seconds which is a normal status when measuring high resistance 2 When input terminal is in open circuit overload displays 3 When measuring in line resistor be sure that the power is off and all capacitors are released completely 4 Do not input voltage at the range of resistance it is forbidden absolutely Diode and Continuity test 1 Apply the black test lead to COM terminal and the red one to V O terminal the polarity of red lead is 2 Set the knob to Prange connect test leads to the diode under test the red test lead connect to diode positive polarity the reading is the approx value of diode forward volt drop 3 Apply test leads to two points of tested circuit if the inner buzzer sounds the resistance is less than 70 20 Q Battery test Set the range to 1 5V or 9V it can test if the 1 5V or 9V battery has enough working current thus can judge the quality of battery MAINTENANCE Do not try to modify the circuit NOTE 1 Do not input voltage over than DC 600V or AC 600Vrms 2 Do not measure a voltage on range 0 3 Be sure to fit on the battery correctly and close the cabin before taking measurement 4 Remove the test leads off testing points and turns off the meter before replacing battery or fuse BATTERY REPLACEMENT EUG WWW AXIOMET EU NOTE Pay attention to the battery status Please replace the
5. rent is 10mA WWW AXIOMET EU PANEL DESCRIPTION 1 LCD displaying display the value and unit 2 knob switch change the test function and range 3 10A current test jack 4 Voltage resistance current jack less than 200mA current test jack 5 GND DC Voltage Measurement 1 Apply the black test lead to COM terminal and the red one to V O terminal 2 Set the knob to a proper DCV range and connect the leads crossly to the electric circuit under test LCD displays polarity and voltage under test connected by the red test lead Note 1 Firstly users should set the knob to the highest range if users had no idea about the range of voltage under test then select the proper range based on displaying value 2 When LCD displays icon 1 meter is over range thus should set the knob to a higher range 3 Max input voltage is 600V over it might damage the circuit 4 Please avoid touching high voltage circuit when measuring it AC Voltage Measurement 1 Apply the black test lead to terminal and the red one to V O terminal 2 Set the knob to a proper ACV range and connect the leads crossly to the electric circuit Note 1 Firstly users should set the knob to the highest range in the case of no idea about the range of voltage under test and then select the proper range based on displaying value 2 When LCD displays icon 1 meter is over the max Value of range th
6. us should set the knob to a higher range 3 Max input voltage is 600Vrms over it might damage the circuit 4 Please avoid touching high voltage circuit when measuring it DC Current Measurement EUG WWW AXIOMET EU 1 Apply the black test lead to COM jack and red to V O mA jack 200 or the red to 10 jack Max 10A 2 Set the knob to a proper DCA range and connect the leads in series to the electric circuit under test LCD displays polarity and current value under test connected by the red test lead Note 1 First set the knob switch to the top range if you do not know the approximate value of the measured current and then select the appropriate range based on the displayed value 2 If the LCD shows only 1 it means that the measuring range has been exceeded Select a higher range using the knob switch 3 Max input current is 200mA 10 depends the insert position of the red test lead over large current will melt the fuse When measuring if the meter is no reading display please check the relevant fuse Resistance measurement 1 Apply the black test lead to COM jack and the red one to V Q jack 2 Set the knob to a proper resistance range and connect the leads crossly to the resistance under test Note 1 The LCD displays 1 while the resistance is over the selected range The knob should be adjusted to a higher range When resistanc