Home

Trainer 201 specifications

image

Contents

1. leere 11 Priming the fluid pump 00 eee 12 Remote control unit 0 0 eee eee 12 D ctlng ar es ose a ar Seb ated sage Sates 13 Operation 22m nennen nennen nennen nn 14 Starting the Trainer 201 oooccccoccccco 14 Operating with the remote control 2222er 15 Basic service oooocooooccoo te nenn nn 16 Fluid system 2 eed em Ber eed Ql ee 16 FUG ARON soror E ende eres 16 Cleaning i e aaa a ea e a nn 16 Replacing a fuse ooooccoccccco nanana 17 Troubleshooting aa 18 Trainer 201 specifications o oo ooccooooooo 19 Introduction The Trainer 201 from MSS Professional is a versatile smoke and fog generator for professional use It can produce a variety of effects from an optically translucent haze to a dense white out that very effectively simulates dense smoke for realistic firefighter training The powerful output makes the Trainer 201 highly suitable for distributing smoke via ducting The Trainer 201 has been designed to cope with the rigors of training with a tough outer casing and rugged water resistant design A total fluid capacity of 2 5 liters 5 3 US pints 4 4 Imp pints ensures good autonomy between refills To allow safe and reliable operation a direct ceramic thermal cutout system shuts down the machine in the event of overheating The Trainer 201 is controlled using a multifunction cable remote control unit that is
2. Reinstall and tighten the fuseholder before reapplying power Basic service 17 Troubleshooting 18 Problem No fog output when the machine is fired using the FOG ON or TIMER functions Probable cause s Machine is not ready Suggested remedy Allow time to warm up Fluid is below minimum level Add fluid Standby switch is OFF Set Standby to ON Timer on period RUN is set to level 0 Set RUN to at least level 1 Machine is not ready after 7 minutes heating time Standby switch is OFF Set Standby to ON Electrical malfunction Refer to MSS Professional Fog disperses too quickly Density level too low Increase OUTPUT setting on multifunction remote POWER LED on remote does not light when power is applied and smoke cannot be produced Remote control not correctly connected Power not correctly connected Check connection Check connection Main fuse blown Replace Electrical malfunction Trainer 201 user manual Refer to MSS Professional Trainer 201 specifications Physical Dimensions LXW xH 500 x 225 x 165 mm 20 x 9 x 6 6 in Shipping dimensions L x W x H 670x 310 x 300 mm 26 4 x 12 2 x 11 9 in Weight without fluid esses Weight with fluid llle RR 13 5 kg 29 8 Ib Performance Maximum smoke output 500 cubic meters 17 600 cubic ft per minute Maximum operating time at full outpu
3. bottom of the container 5 When using the machine for the first time or after fluid containers have been changed prime the pump see below Installation 11 12 Priming the fluid pump When using the machine for the first time or after fluid containers have been changed the fluid pump must be primed To prime the pump 1 Apply power and allow the machine to warm up 2 When the READY LED on the machine lights turn the OUTPUT knob on the remote control fully clockwise to set the machine to maximum output 3 Use the FOG button to fire the machine for approximately 10 seconds or until smoke is produced at the output nozzle If smoke is not produced within 20 seconds there may be a problem with the fluid system Refer to Troubleshooting on page 18 for fault finding procedures Remote control unit The Trainer 201 is supplied with a cable remote control unit connected and secured with two thumbscrews in its on board docking station The remote is connected to the Trainer 201 via a hard wired 6m 19 5 ft cable and 3 pin XLR connector A longer cable can be fitted upto a maximum cable length of 25 m 82 ft Standard microphone cable can be used The pin configuration of the remote connection is Pin 1 Ground Pin 2 16 V output from machine e Pin 3 0 10 V input to machine Trainer 201 user manual Power the Trainer 201 off before disconnecting or connecting the remote control unit The optional smok
4. is installed can safely hold the weight of the machine Suspending the machine directly over people s heads is not recommended Use smoke ducting instead Do not point smoke output directly at a person s face or at face height Smoke machines can cause condensation If smoke concentration is high for extended periods floors and surfaces may become slippery Wipe dry as necessary to avoid any danger of slipping Trainer 201 user manual Smoke fluid contains food grade glycols in solution but may present health risks if swallowed Do not drink it Store it securely If eye contact occurs rinse with water If fluid is swallowed give water and obtain medical advice Preventing breathing problems A smoke machine can operate safely only with the exact type of smoke fluid it was designed for Use the machine only with Martin Security Smoke Trainer Fluid or you may cause the release of toxic gases presenting a severe health hazard You will also probably damage the machine Disposing of this product MSS Professional products are supplied in compliance with Directive 2002 96 EC of the European Parliament and of the Council of the European Union on WEEE Waste Electrical and Electronic Equipment as amended by Directive 2003 108 EC where applicable Help preserve the environment Ensure that this product is recycled at the end of its life Your supplier can give details of local arrangements for the disposal of MSS Profession
5. supplied with the machine The remote can be conveniently fastened in an onboard docking station Details of the full range of MSS Professional training products are available on the MSS Professional website at http www training smoke com The Trainer 201 features Multifunction cable remote control supplied with instant or timer controlled output and onboard docking station Variable smoke output level up to 500 cubic meters 17 600 cubic ft per minute 1kW heat exchanger giving high output from a compact vaporizing system DTP direct ceramic overheat protection 2 5 liters 5 3 US pints 4 4 Imp pints onboard fluid capacity High power piston pump Pump ramping for continuous output Heavy duty construction Water resistant design Optional 4 inch smoke ducting adaptor kit 8 Trainer 201 user manual Installation DANGER Do not try to install the Trainer 201 until you have read and observed all the precautions listed in Safety information on page Unpack and check the machine The Trainer 201 is supplied with Multifunction remote control with 6 m 19 5 ft cable 2 5 liters 5 3 US pints 4 4 Imp pints smoke fluid container Power cable a suitable power plug must be supplied by the user Machine location The Trainer 201 must be placed securely on a level stable surface that can safely support its weight Installing the machine above people s heads is not recommended If smoke outpu
6. switch on the remote control to ON 3 The remote control becomes functional when the READY LED on the back of the Trainer 201 lights after approximately 7 minutes warm up time If you are starting the machine for the first time or after the fluid has been changed the pump may need to be primed Do this by setting OUTPUT to maximum and firing the machine for 10 seconds or until smoke is produced 14 Trainer 201 user manual Operating with the remote control The Trainer 201 can be controlled using the multifunction cable remote as described below STAND BY TIMER 4e E ne ar une 10 is POWER 3 OUTPUT DELAY Wu 1 E QN A 5 N na P 21 2g EE 28 S Y o A ON When the machine has reached operating temperature press and hold this button to produce instant smoke output B STAND BY Puts the machine into standby mode Switch to ON for warm up and operation C TIMER x8 When using the timer increases timer values by a factor of 8 so that for example a 5 second run time becomes 40 seconds and a 10 second delay time becomes 1 minute 20 seconds D TIMER ENGAGE Engages the timer to produce smoke according to the OUTPUT DELAY and RUN settings E OUTPUT Turn clockwise to increase smoke output Turn fully counter clockwise for zero output F POWER This LED lights when th
7. this manual but still believe that the machine is malfunctioning please contact MSS Professional on 44 1604 839 000 or 45 87 400 000 Preventing electric shocks Always ground earth the machine electrically The machine may only be connected to AC power via the power cable supplied with the machine or a replacement supplied and installed by MSS Professional Use only a source of AC power that complies with local building and electrical codes and that has both overload and ground fault protection Before connecting the machine to power check that the voltage range indicated on the machine s serial label matches your local AC power voltage If your AC power voltage is outside the range indicated do not use the machine Contact MSS Professional for assistance Before using the machine check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected devices Safety information If the machine or any cables connected to it are in any way damaged defective wet or show signs of overheating stop using the machine and contact MSS Professional for assistance Disconnect the machine from AC power before refilling or changing the fluid container before servicing and when not in use This machine is water resistant but not totally waterproof Do not immerse in water or any other liquid Do not expose to high pressure water jets Do not spill fluid ov
8. al products Safety information 5 Product overview B C D M STAND BY M TIMER T ON x8 ON MULTI FUNCTION CONTROLLER 5 5 254 aS 4 6 MIU stas es SN QW N W 7 2 tn G E G POWER 7 3 CYOLE 4 SS a i OUTPUT O DELAY e FH F G Za wy n 0 a Ne WU 11 Y uan eo N ND o E H Machine Remote control unit 1 Output nozzle A Instant smoke output 2 Carrying handle B Stand by set to ON to operate 3 Air vents C Timer value multiplier 4 Fluid container D Timer engage 5 Multifunction remote control E Smoke output level 6 READY LED F Power indicator 7 Power on off switch G Delay sets intervals between 8 Power cable entry output 9 Main fuseholder H Timer operation indicator Output sets output periods 6 Trainer 201 user manual Contents Safety information 0000 c een 3 Product overview 2222er 6 Introduction 2 22 2en een 8 ESAS ata Sn en 8 Installation 2204 ee ete a en Rx s 9 npacklng er mue nu pM erede tee iil ko 9 Machine location oooooccoocccooccc EE a a aa 9 AG POWER a 9 Fluid system 2 nen 10 Fluid type ooi re RUN 10 Fluid capacity oy care e ena een nennen 11 Continuous output and pump ramping 11 Filling with smoke fluid
9. e ducting adaptor available from MSS Professional allows the Trainer 201 to be connected to standard 100 mm 4 inch flexible smoke ducting The adaptor allows air to mix with the smoke output before it enters the ducting DANGER Do not use any other method than the MSS Professional ducting adapter to connect smoke ducting to the Trainer 201 or you may cause moisture buildup with a risk of electric shocks or damage to the machine that is not covered by the product warranty Good results are obtained with smoke ducting up to 20 m 65 ft total length Avoid sharp bends as far as possible as these encourage condensation Ensure free and unobstructed airflow to the space between the output nozzle and the entry to the smoke ducting Installation 13 Operation DANGER Do not try to operate the Trainer 201 until you have read and observed all the precautions listed in Safety information on page 3 IMPORTANT Do not allow the Trainer 201 to run out of fluid as this may cause serious damage to the product that is not covered by the warranty Starting the Trainer 201 Before operating check that the Trainer 201 is correctly and safely installed that the fluid container is filled with enough fluid see Fluid system on page 10 and that the remote control is connected To start the Trainer 201 from a cold state 1 Connect the Trainer 201 to power and switch on at the power switch on the machine 2 Set the Standby
10. e machine is switched on G DELAY Turn clockwise for longer intervals between smoke output periods when the timer is engaged H CYCLE This LED lights when the timer is engaged and the machine is operating RUN Turn clockwise for longer smoke output periods when the timer is engaged Operation 15 Basic service 16 DANGER Do not try to service the Trainer 201 until you have read and observed all the precautions listed in Safety information on page 3 Any service not described in this section must be carried out by a service technician authorized by MSS Professional Please refer to MSS Professional for assistance with obtaining service Fluid system DANGER Use ONLY Martin Security Smoke Trainer Fluid in the Trainer 201 NEVER operate the machine with any other type of fluid or toxic gas may be produced You will probably also cause damage to the machine that is not covered by the product warranty For general information about the fluid system see Fluid system on page 10 For instructions for filling the Trainer 201 with smoke fluid see Filling with smoke fluid on page 11 Fluid filter The Trainer 201 uses a washable filter on the end of the smoke fluid suction tube Check that the filter is perfectly clean each time you change or refill the smoke fluid container If the filter is dirty or contaminated wash in clean water until perfectly clean or replace with a new item Excessive d
11. er the machine If fluid is spilled clean the machine with a damp cloth If fluid is spilled onto electronic parts contact MSS Professional for advice Do not remove the covers or attempt to repair a faulty machine Refer any service not described in this manual to MSS Professional Do not operate the machine if any parts are damaged defective or missing Preventing burns and fire The smoke expelled from the output nozzle is hot enough to cause burns and very hot droplets of fluid occasionally escape from the nozzle area Keep people and objects at least 1 m 40 inches away from the nozzle Do not touch the smoke output nozzle area during or after use it may stay hot for several hours after the machine has been used Provide a minimum free space of 10 cm 4 inches around the machine and ensure free and unobstructed air flow to and around the machine Keep the machine at least 60 cm 24 inches away from combustible and heat sensitive materials Do not attempt to bypass thermostatic switches fluid sensors or fuses Replace fuses only with ones of the type and rating specified in this manual and on the machine for the local AC power voltage Do not operate the machine if the ambient temperature T4 is below 5 C 41 F or above 40 C 104 F Do not operate the machine if the relative air humidity exceeds 80 Do not recycle dense smoke into the machine Preventing injuries Ensure that the surface on which the machine
12. ics Electrical 115 V model AC DOWOL een 110 120 V 60 Hz nominal Power and current 0 0 0 0 0 ccc eee eee ee 1070 W 9 72 A Main fuse 0000 cee eee eee T 15 A slow blow 250 V 230 V model AC POWEL iducu lr en an BE 220 240 V 50 Hz nominal Power and current 0 0 0 0 0 1070 W 4 45A Main fuse exch unen Reps T 6 3 A slow blow 250 V At nominal voltage Your local voltage may fluctuate Allow for 1096 variation Connections Power inlet Hard wired grounding earthed 2 m 6 5 ft cable tail w o plug Cable remote control connection liiis 3 pin XLR Ducting Optional adaptor for 100 mm 4 inch flexible ducting Approvals This product meets the requirements of the following EC Standards and as such complies with the EMC and LVD directives of the European Community European EMC EN 50 081 1 EN 55 014 EN 55 022 B EN 60 555 European safety 0020 2 eae EN 60 335 1 Immunity EN 50 082 1 IEC 801 2 IEC 801 4 Included Items Multifunction remote control with 6 m 19 5 ft cable Accessories 2 5 liter container MSS Professional Trainer Fluid Medium P N 97121223 2 5 liter container MSS Professional Trainer Fluid Heavy P N 97121226 9 5 liter container MSS Professional Trainer Fluid Medium P N 97121224 9 5 liter container MSS Professional Trainer Fluid Heavy P N 97121227 25 liter containe
13. nd maximum continuous output level vary slightly at different input voltages Continuous output and pump ramping The Trainer 201 uses a technique called pump ramping to allow continuous smoke output during the entire operation period When the output level is set to maximum the machine gives maximum output for approximately 1 minute until the heat exchanger has used its energy reserves The pump ramping system then reduces the output level overriding the output level setting for the rest of the operation period This System ensures that output is continuous Filling with smoke fluid Important Keep smoke fluid and all components in the fluid system free of dust dirt fluff and any form of contamination Do not shake or vibrate the fluid container or machine as this will create air bubbles in the fluid Excessive bubbles impair performance and may cause damage to the heat exchangers that is not covered by the product warranty To fill the Trainer 201 with smoke fluid 1 Isolate the Trainer 201 from power 2 Fita full container of Martin Security Smoke Trainer Fluid into the fluid compartment and remove its cap 3 Check that fluid and all components are totally free of dirt fluff and other small particles Impurities will clog the machine and make service or repair necessary 4 Install the Trainer 201 s fluid adaptor cap complete with fluid lines tightly on the fluid container ensuring that the suction tube reaches the
14. nn Trainer m 57 USER MANUAL TRAINER 201 Dimensions All dimensions are in millimeters 2006 2010 MSS Professional A S All rights reserved No part of this manual may be reproduced in any form or by any means without permission in writing from MSS Professional A S Denmark Information subject to change without notice MSS Professional A S and all affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document P N 35000180C Safety information The following symbols are used to identify important safety information A A A A Danger Safety Danger Hazardous Caution Burn Caution Fire hazard Risk of voltage Contact hazard Hot hazard personal injury will cause electric surface Do not shock touch DANGER This product is not for household use Read this manual before operating the machine follow the safety precautions listed below and observe all warnings in this manual and printed on the machine Use the machine only as described in this manual and in accordance with local laws and regulations Refer any service operation not described in this manual to a qualified technician If you have questions about how to operate the machine safely or if you have followed the instructions in
15. r MSS Professional Trainer Fluid Medium P N 97121225 25 liter container MSS Professional Trainer Fluid Heavy P N 97121228 MSS ducting system incl 5 m of 100 mm 4 inch ducting P N 92622024 Ordering information Trainer 201 115 V 60 HZ inha sa borda tr abad P N 92256110 Trairier 201 230 V 50 Hz nn a aaa P N 92256100 Specifications subject to change without notice Supplier MSS Professional A S MSS Professional Ltd Brunbjergvej 6 Rectory Court High Street 8240 Risskov Kislingbury Denmark Northampton Tif 45 72 170 O11 Northamptonshire Fax 45 86 170 055 NN7 4AG www training smoke com England Tel 44 01604 839000 Fax 44 01604 832666
16. s serial label matches your local AC power voltage If your AC power voltage is outside the range indicated do not use the machine Contact MSS Professional for assistance Fluid system DANGER A smoke machine can run safely only on the specific smoke fluid or fluids it is designed for Use ONLY Martin Security Smoke Trainer Fluid in the Trainer 201 NEVER operate the machine with any other type of fluid or toxic gas may be produced You will probably also cause damage to the machine that is not covered by the product warranty Fluid type The type of fluid used affects the density and persistence of the smoke produced Two fluids are compatible with the Trainer 201 e Martin Security Smoke Trainer Fluid Medium gives a medium density smoke with medium persistence and is suitable for general use Martin Security Smoke Trainer Fluid Heavy gives a higher density smoke with higher persistence This fluid is suitable for large areas and where maximum smoke density is required Trainer 201 user manual Important Fluid capacity Check the fluid level regularly Do not allow the Trainer 201 to run out of fluid Attempting to operate the machine with no fluid may cause damage that is not covered by the product warranty The Trainer 201 has an on board container with a capacity of 2 5 liters 5 3 US pints 4 4 Imp pints giving approximately 1 hour 20 minutes of continuous operation at full output Maximum continuous operation time a
17. t Approx 1 hour 20 minutes Operating time Continuous automatic output level adjustment Warm up time ooooocccoccc e Approx 7 minutes Control Multifunction cable remote 0 10 V analog Instant smoke stand by timer X8 and timer engage push buttons LED power and timer cycle indicators Independent output level timer delay and timer runtime controls Timers 2 144 sec delay 2 144 sec runtime Installation 11 kg 24 2 Ib Minimum clearance in front of output nozzle 1 m 40 inches Minimum free space around machine 10 cm 4 inches Minimum distance to combustible materials 60 cm 24 inches Orientation isses eee RR RR re hn Maximum 30 from horizontal Minimum ambient temperature 0 0000 eee eee eae Maximum ambient temperature 0 0002000 eae Heat exchanger 40 C 104 F Header M e ce tet Le EO BM MAMA Y E 1 kW at 240 V Thermal protection 00 Direct ceramic thermal trip device Temperature control 2 222 22er Electronic thermocouple Fluid system Approved fluid Martin Security Smoke Trainer Fluid Medium or Heavy On board fluid capacity 2 5 liters 5 3 US pints 4 4 Imp pints Fluid consumption at max continuous output 75 ml per minute Fluid Bump e aaa A Eris Piston high pressure Pump Startup 2 22 22m onen rennen nn Soft start electron
18. t above ground level is required the easiest solution is to use flexible smoke ducting Ensure that there is a minimum free space of 10 cm 4 inches around the machine unobstructed air flow around the machine minimum 1 m 40 inches free space in front of the nozzle and a minimum distance of 60 cm 24 inches to combustible materials wood paper etc AC power The Trainer 201 is available in two models The 115 V model accepts 110 120 V 60 Hz nominal AC power The 230 V model accepts 220 240 V 50 Hz nominal AC power Both models are supplied with a 2 meter 6 5 ft power cable Before using the machine a grounding type earthed power plug that fits the local power outlets must be obtained locally and installed on the power cable Installation 10 DANGER Make sure the power plug is correctly rated 115 V models must be fitted with a plug rated 15 amp minimum 230 V models must be fitted with a plug rated 6 3 amp minimum When installing the plug follow the plug manufacturer s instructions and connect pins as follows yellow and green wire to ground earth blue wire to neutral and brown wire to live The table below shows some common pin identification schemes Wire Pin Marking Screw color brown live zi yellow or brass blue neutral N silver yellow green ground earth an green Before connecting the Trainer 201 to power check that the voltage range indicated on the machine
19. ust smoke fluid and dirt buildup will degrade performance and cause overheating and damage to the machine that is not covered by the product warranty To maintain adequate cooling dust must be cleaned from the outer casing and air vents periodically Isolate the machine from power and allow to cool completely before cleaning The nozzle area can remain hot for several hours after use Remove dust from the air vents on the side of the outer casing with a soft brush cotton swab vacuum or compressed air Clean the outer casing with a damp cloth only Trainer 201 user manual Ensure that the nozzle area ia completely cool then wipe up any smoke fluid residue from the nozzle and surrounding area with a damp cloth Replacing a fuse DANGER Disconnect the machine from AC power before removing or installing a fuse Never attempt to bypass a fuse or replace a fuse with one of a different type and or rating If a new fuse blows shortly after it is installed stop using the machine and contact MSS Professional for assistance If the main on off switch and the power LED on the remote do not light when power is applied the main fuse may have blown To replace the fuse 1 Isolate the machine from power and allow to cool 2 Use a flat headed screwdriver to open the main fuseholder next to the power cable entry 3 Replace the main fuse with one of the same type and rating only see Electrical on page 20 for fuse details 4

Download Pdf Manuals

image

Related Search

Related Contents

DeepSee Model Design Guide - InterSystems Documentation  Intel R1208JP4OC server barebone  IL VAPORE NEGLI OSPEDALI  Tracker Para Carro - Sava Internacional SAS  DT 3D/DT  MANUAL DO USUÁRIO - Plantec Distribuidora  Microlife MT 500 Navigation Manual  McGrey PK-6110USB Professional-Keyboard Bedienungsanleitung  Piano di cottura in vetroceramica Toptronic 2 zone Istruzioni per l`uso  Nobo Self Adhesive Gridding Tape  