Home
Integra32 User Manual
Contents
1. PTZ Camera Pre Event Time Post Event Time fo I tin One way the interface can be used is to associate the reader with a specific DVR DVRs are set up in the Database Screen under DVR First select a DVR for the pull down list under DVR Name Next configure the Camera Information Select a camera number indicate whether it s a PTZ camera or not and if it is enter a preset number if applicable Then set the History Information Set the Pre Event Time and the Post Event Time These times set playback start time how much time before the event time and the playback end time how long to continue the playback after the event 16 This selection is only available if the optional license for the DVR Software has been purchased and installed RBH Access Technologies Inc Integra32 User s Guide 65 Chapter 5 Programming time This configuration is used by the History Reports DVR tab to playback video associated with a logged event The second way is by using ASCII messages M Send ASCII Message to DVR First select the camera number you want to display from DVR Then enter the DVR s IP address and Port Number associated with the camera you selected as you could be using more than one DVR this configuration is used by the History Reports DVR tab to playback video associated with a logged event Integra32 User s Guide RBH Access Technologies Inc 66 Advanced x General Modes Time
2. RBH Access Technologies Inc Integra32 User s Guide 145 Chapter 12 Program Groups Click Next after the appropriate file has been selected Integra32 Firmware Upgrade Wizard Select panels to upgrade PR Network 1 Panel 1 Metwork 1 2 Panel 2 Network 1 Da Panel 3 Network 1 4 Panel 4 Metwork 1 1 Panel 5 Network 2 2 Panel 6 Network 2 Da Panel 7 Metwork 2 4 Panel 8 Network 2 Ji Panel 9 Network 3 lt Back Mext gt Close Next select which panel s should be downloaded to Then click Next You don t have to select all the panels at this time After upgrading you can come back to this screen Integra32 User s Guide RBH Access Technologies Inc 146 Chapter 12 Program Groups Clicking Start will begin the download Integra32 Firmware Upgrade Wizard Upgrade status Upgrade started to panel 1 Panel 1 1 Panel 1 Firmware upgrade completed to panel 1 Panel 1 Upgrade started to panel 4 Panel 4 Back ext Close A progress bar and messages will keep informed during the proceedings There will be a completed message after each panel download You can go back to select other panels or close 1f you are finished downloading Integra32 Security System There are two ways to start the Integra32 system You can either double click the icon that was created when the system was installed or you can click on
3. Chapter 10 Links Global Links Global Links x ACCESS Points Input Points i Output Points Panels Device Select an event Output 1 1 Output On a Duration Schedule coca Global Links like Global APB require the interaction of the PC These links cannot be executed 1f the PC is not online As with local links you choose which event on what device will cause the link to be executed Then you can choose up to eight things to have happen These links can be executed on any panel in the system Details on programming links can be found in Chapter 5 under Access Points Inputs and Outputs Integra32 User s Guide RBH Access Technologies Inc 122 Chapter 11 Tools Chapter 11 Tools Backup The Integra32 Backup Configuration Wizard is used to backup your data files You can run the Backup immediately or configure the auto backup to run at a later time Your Operating System most likely will also have its own backup utility It doesn t matter what method you use as long as you backup your files regularly It s not a matter of if a hard drive fails but when Unknown Integra32 AxiomLite Backup Configuration Wizard x This wizard will help you to backup Integra data files f Run backup now C Configure auto backup Cancel 4 Back Next gt Firnteh Run Backup Now Run Backup Now option is used to run an immediate backup Follow the wizard for this
4. tft sil le Bi E E Semi permanent Access Inputs Outputs Panels Areas Cardhalders 2 ES ai O a a da Q Output4 Y Tumon Dif E Output Turm off ari G Output E Ort E A T Output 11 E On Output 12 E Play Ot G Output 15 Ort 4 The following commands for output points are available by right clicking the selected Output Points Commands Turn On Turn on an output Turn Off Turn off an output Live Select Live to display live video from the CCTV camera associated with the selected output point Play Play will bring up a DVR history selection screen so that video connected to an event for the chosen output point can be played back 2 This selection is only available if the optional license for the DVR Software has been purchased and installed 13 This selection is only available if the optional license for the DVR Software has been purchased and installed Integra32 User s Guide 17 RBH Access Technologies Inc Chapter 3 Monitor Screen Panels Commands Clicking the Panels button on the Command Toolbar depicts the status of panels on the Device Status Screen 5 e Description DownLoad Reset Clear log Schedule Inguiry ACCESS Inputs Outputs Panels pa Z e e Dn Panel Version Online 2 BE Pane ul Set date time Online E He Panel 4 Get date time Online A AA a E Cardholders All Files E E Areas Cardholders Floors a IRC
5. Chapter 8 Reports 10 x x amp amp Fite 00 y 14 4 J gt o e Preview 24 Apr 2009 Date 5 Way 2009 y ar ni fe e Integra32 Cardhol Date Message Location 24 Apr 2009 74S 00arn lode charnged Urdock pending first Reader 1 Panel 1 person by schedule 10 41 44am Access granted Card Reader 13 Panel 7 10 45 26am Access granted Card Feader 13 Fanel 7 10 47 26am Access granted Card Reader 13 Fanel 7 10 4 03am Access granted Card Reader 13 Panel 7 104 Sear Access granted Card Reader 13 Panel 7 10 49 07arm Access granted Card Reader 13 Panel 7 10 54 23am Access granted Card Reader 13 Panel 7 10 32 42am Access granted Card Feader 13 Panel 7 10 55 22am Access granted Card Reader 13 Panel 7 10 55 4Darn Access granted Card Reader 13 Panel 7 10 55 54amn Access granted Card Reader 13 Panel 7 10 44 Wee base cated awe Drrndar 177 rr ld 7 From this report the user has the option of Printing Exporting the file Refreshing the preview of the report or changing the current view of the report Integra32 User s Guide RBH Access Technologies Inc 108 Chapter 8 Reports DVR Clicking the DVR button from the toolbar of the History Report window the user can preview the Send Camera Commands window to select the History Event Command he she wants to send to the DVR Send DYR Commands 10 x e O x Ooo A CTE Mode changed Unlock pending firs Reader 1 Panel 1 xl Gi Mar 2006 10 41 44 emf Access ented Cad Fea
6. Dealernfoz 2 Automatic Road Suite 106 Dealerlntos Brampton Ontario Diealerlntod supportic rbh access com RBH Access Technologies Inc Integra32 User s Guide 7 Chapter 2 Getting to know Integra32 Toolbar Buttons E gt E ras a El a En Log Out Status Alarm AP Activity Lards Visitors DWF Help E E Log In Log Out Login Logout Press this button to log in or log out of Integra32 system Status Status Press this button to change the Command Screen to display the status of access points inputs outputs and panels Mie FOs A lie Alarms Press this button to change the Command Screen to display alarm messages time and date of alarm and operator ID This change will take place automatically when an Alarm Event occurs B AF Activity AP Activity Press this button to toggle on and off the Access Point Activity screen pop up Ea mai Cadhollas Press this button to launch Integra32 s cardholder window to program new cards or edit existing cards ia Visitors i Visitors Press this button to launch the Integra32 s visitor window to administer visitors in the system EH DWA DVR Press this button to launch the DVR module to monitor the CCTV system live This selection is only available if the optional license for the Visitor Management System has been purchased and installed This selection is only available if the optional license for the DVR Interface has
7. Fields and Options The cardholder window contains following fields and options File Exit Select this option to leave the Cardholder screen New To add a new cardholder click on the New button then the cardholder s information can be entered Edit To make changes to an existing cardholder click Edit then make the necessary changes Save To save changes made to a cardholder click Save Cancel Cancel will exit the edit mode without saving any changes to cardholder Delete Cardholders that are no longer required can be removed from the database with the Delete button All cards with this cardholder are deleted with it Search To search for a cardholder click Search There are many fields to search by select one and enter your perimeters then click Search Multi Cards Multi Cards will open a utility to add multiple cards in a sequence to the cardholder utility as well as to the panels F Print F Print will open the Touchstar finger print registry screen Last Name Enter the cardholder s surname First Name Enter the cardholder s given name Initials Up to six characters can be entered Cardnumber Enter a number here to be used as a search parameter This selection is only available if the optional license for the Finger Print Reader has been purchased and installed RBH Access Technologies Inc Integra32 User s Guide 85 Chapter 6 Cardholders Multi Cards x Start Cardnumber Activation Date
8. Select the time and day s to run the backup JF 021500 Sure e Mon Tue e Wed e Thu fw Fi p Sa Overwrite backed up file after following number of day s Cancel Back Het gt Finish Click Finish to allow the system to run the auto backup at the specified day and time Integra32 User s Guide RBH Access Technologies Inc 124 Chapter 11 Tools Restore To restore backed up files you must log into Integra32 Data Restore Integra32 Data Restore 18 located under Programs gt Integra32 Security System which is accessed by clicking Start You will be required to login before getting to the Data Restore Screen Select source folder C sPrograrn Files oR ntegras2 0 efaultyB ackup BR P20100 El Select the file s to restore AxuserlT mdb Asswstl 7 mdb Cancel 4 Back Hest gt Pints The Data Restore Screen allows you to select which files are to be restored You can even select which image files are to be restored Integra32 User s Guide 125 RBH Access Technologies Inc Chapter 11 Tools Void Cards From Void Cards the operator can manually void deactivate cards that have not been used for a preset number of days The number of days is set under Options System Options Void Card Utility Oj x 8 Print 4 Inactive Y Select All Card Number Department iq Print will produce a hard copy of the cardholders listed at the time Print is se
9. 63 60 62 14 26 24 25 114 24 10 24 114 67 2i 33 23 114 124 123 115 130 62 132 42 5 133 84 90 91 94 91 99 22 99 26 19 Command Bar Command Type Conventions in this guide Copyright D Data Restore Database Maintenance Database Reports Database Screen Deactivation Date Deduct Usage Disable Forced Entry Disarm Keypad Door Held Open Download DVR Toolbar Button E Elevators eMail Configuration Event Log Screen Exit Extended Unlock Time F F Print Facility Code Mode File Finger Print Firmware Upgrade First Person Delay Floor Groups Floors Font G Getting to Know Integra32 Global Antipassback Global Links Glossary Group Cards H Handicap Help Help Toolbar Button High Security High Security Privilege History Reports Holidays 145 145 110 91 60 60 23 62 19 20 79 120 11 62 92 85 88 15 61 127 145 61 81 22 117 67 122 150 114 92 61 92 105 30 RBH Access Technologies Inc How to Execute a Command I Ignore Antipassback Import Utility Inhibit ID Input Points Commands Input Properties Inputs Alarms CCTV Details Links Integra32 Database Integra32 Server Client Network Setup Integra32 Database Maintenance Integra32 Registration Integra32 Security System Integra32 Site Configuration Interlock Introducing Integra32 IRC2000 Properties K Keypad Commands L License amp Warranty
10. Any alarms received when the buffer is full are logged to history but do not get sent to the Alarms Screen Alarm Details The user can see the details of an alarm event in Alarm Details Window by double clicking the alarm event in the Alarms Screen Date This box shows the date and time that the alarm occurred Integra32 User s Guide RBH Access Technologies Inc 24 Chapter 4 Alarm Screen Age The age of an alarm is the number of seconds since the alarm happened Status Status shows whether the alarm has been acknowledged Alarm Alarm provides a description of the alarm Instructions This box will display instruction messages assigned to the alarm Action Messages The operators can enter their own message into this box indicating what action was taken because of this alarm Alarm Details xX worl e Date Age Status Alarm Instructora 4 F Acton Messages RBH Access Technologies Inc Integra32 User s Guide 25 Chapter 4 Alarm Screen Acknowledge Acknowledge the highlighted alarm with this selection Y Acknowledge All Acknowledge all of the alarms in the Alarm Window with this selection Unacknowledge Unacknowledge the highlighted alarm with this selection Clear Clear the highlighted acknowledged alarm with this selection Clear All Clear all of the acknowledged alarms in the Alarm Window with this selection Live Select Live to display live video from the
11. Enter here a description or name for each PIN code Integra32 User s Guide RBH Access Technologies Inc 90 Chapter 5 Programming Links Panel Properties q x 1 Print Lancel Apply Event Select from a pull down list the triggering event Device ID Choose the appropriate device to execute the selected command from a pull down for the selected event Card Enter the card number if applicable that will trigger the selected command when it is associated with the chosen device and selected event e g execute the command when card 1234 is granted access at reader 1 Command Select the command to be executed on the chosen keypad from a pull down list Arm Keypad Disarm Keypad or Arm Perimeter Keypad Choose which keypad the command is to be executed on Pin Code Select a valid PIN code The command will be executed as though this PIN code had been entered RBH Access Technologies Inc Integra32 User s Guide 91 Chapter 5 Programming Summit The PC100 when made for the Summit application will interface the Electronics Line Gold alarm panel to the IRC2000 access control system The PC100 comes with three channels of communication all if which are programmed for a baud rate of 9600 eight data bits and no parity The PC100 passes data to and from the host to the IRC network and listens for log messages In the event where the host is disconnected the PC100 sends request for status fro
12. It 1s recommended that the user be familiar with the Risco Group panel and has the ability to program PIN codes and parameters into the panel The PC100 interface has been designed to connect the Integra32 network to the Risco Group alarm panel through the option or keypad bus It will emulate a keypad when a link has been provided and report status to the Integra network when included in the list of keypads In order for the alarm panel to poll the emulated keypad the keypad assignment for the alarm panel should be programmed Keypad addresses 1 10 connect to the keypad bus and addresses 11 15 is connected to the option bus The PC100 can monitor all keypads on the bus that are listed under panel properties Keypads A Link to an Event will use an emulated keypad to enter a password followed by a command If the password 1s not programmed into the alarm panel no operation will take place Whenever a command is executed the green Health LED will turn on The green Health LED will turn off when the alarm panel finishes its poll to the keypad Integra32 User s Guide RBH Access Technologies Inc 54 Chapter 5 Programming General Panel Properties x General Keypads PIN Code Links Address Description J2 PE OO 32 Panel type Pct 00 Risco Group coo Ao Address The address is selected at the time creation and cannot be edited later Description To change the d
13. Link Execute Privilege Links Local Antipassback Log In amp Out Ctrl L Login Logout Toolbar Button M Magnetic Encoder Setup Menu Options Messages Monitor Screen Multi Cards N Networks Advanced Comms Direct Connect Ethernet Connect Modem Connect General O Options Out Reader Output Points Commands RBH Access Technologies Inc 13 91 133 61 16 70 74 71 70 73 21d 145 148 147 148 15 41 23 151 91 92 67 116 34 12 85 86 35 40 36 36 39 37 35 68 17 Output Properties Outputs CCTV Details Links P Panels Alarms Code Reader Links Dial Out Reader Options Site Codes Panels Commands PC Decision Required PC100 Permanent Command Preview Reports Print Area Report on Input Program Groups Programming Properties Notes Tab Q Query Finger Print Reader R rbh ini Receipt Registration Repeat Ignore Time Reports Reset Area Restore Backup RTE Bypass DC Run Backup Now S Schedules Semi Permanent Command Set Area Set Date Time Site Configuration Status Screen System Messages System Options System Status System Status Toolbar Button T Time Zone Difference Time Zones Timed Antipassback Index 75 76 75 78 41 44 44 45 42 43 18 61 48 13 106 114 144 2 95 129 99 148 63 6 105 21 125 61 123 31 13 21 19 148 10 118 113 12 40 31 Integra32 User s Guide 153 In
14. Personal Identification Number Request to exit RTE TAPI Telephony Application Programming Interface TAPI is a Microsoft Windows set of functions that allows programming of telephone line based devices in a device independent manner giving personal telephony to users TCPAP Transfer Control Protocol Internet Protocol TCP IP is the protocol that networks use to communicate with each other on the Internet Time Group A Time Group e g Business Hours is a pre defined time slot day combination that may be assigned to schedules thereby governing how the Integra32 system operates from day to day Any field apparatus that receives commands from an Integra32 system and executes the action specified in the command Examples include door locks and lights Integra32 User s Guide RBH Access Technologies Inc 150 License amp Warranty License amp Warranty Notice 1 01 This Software is licensed not sold It is licensed to sublicenses including end users without either express or implied warranties of any kind on an as is basis RBH Access Technologies Inc makes no express or implied warranties to sublicenses including end users with regard to this software including merchantability fitness for any purpose or non infringement of patents copyrights or any other proprietary rights of others RBH Access Technologies Inc shall not have any liability or responsibility to sublicenses including end users for d
15. This settings will be used to send email to person being visited Sender Name Senders Email address SMTP Server Send Email as the visitor is checked in The Sender Name is used to let the cardholder know where the visitor is or entering from A site may have more than one entrance that visitors can come in by and the cardholder being visited may need to know where the visitor is M Check the box Send Email as the visitor is checked in to have an email sent automatically to the being visited cardholder The being visited cardholder s Profile Tab must have an email address entered for this feature to work This selection is only available if the optional license for the Visitor Management System has been purchased and installed Integra32 User s Guide RBH Access Technologies Inc 120 Chapter 9 Options User Fields Visitor Management Configuration xx Enter the Description of user fields this description will be then seen on visitor screen Text Field 1 User Text Number Field 1 User MumberT Text Field 2 UserText2 OO Number Field 2 User Number Text Field 3 UserTet3 Date Field 1 User DateT O Text Field 4 User Text 4 Text Field 5 UserTet5 Ok Cancel Define the name of the fields for entering data under the User Fields tabs of Visitor Use this to customize the visitor data saved in your system RBH Access Technologies Inc Integra32 User s Guide 121 Chapter 10 Links
16. gr u MA E User 1 w on Access Points Input Points Output Points Panels Areas Keypads J E Main Keypad a ee Partition 2 pa Partition 3 Arm Keypad a Partition 4 Disarm Keypad tj ae LL Partition 5 Status Commands a Select the name of the PIN code that the command is to be issued by Arm Keypad Arm the selected keypad with the selected PIN code Disarm Keypad Disarm the selected keypad with the selected PIN code Status Partition2 x rm Disarm User 1 General O Armed O Perimeter D Status O Supervisory O Power O Bell Silenced O Fire O Trouble LED keypad status will be displayed in this window Arm amp disarm commands can also be issued from here Integra32 User s Guide 23 RBH Access Technologies Inc Chapter 4 Alarm Screen Chapter 4 Alarms Screen The Alarms Screen displays alarm events and pops up automatically when the Alarms option is turned on in the toolbar of the main screen Date Ss Alarmmessage Operator 3 May 2006 08 38 36 Access point Forced entry alarm Acknowledge Unacknowledge Clear Right clicking the alarm event on the Alarms Screen gives the option to acknowledge the Alarm Right clicking on an Acknowledged Alarm gives the options to either clear or unacknowledge the alarm Once an alarm is acknowledged only the operator that acknowledged that alarm can clear it A maximum of one hundred and fifty alarms can be held in the alarm buffer
17. Integra32 Security System in program groups Both methods will start Integra32 system RBH Access Technologies Inc Integra32 User s Guide 147 Chapter 12 Program Groups Integra32 Integra32 Integra32 User s Guide 148 Site Configuration TT j x Site Mame asc Manufacturing Corp Add Site Remove Site y Type in the name of the site and either click Add Site or Remove Site Sites added will be selectable on the server pull down list while logging on Each site will have its own database and maintains its own backup you must be logged on to the site at the appropriate time for the auto backup for that site to run Registration The software must be registered in order to enable the Badging software the Card Import Utility the Finger Print Reader the DVR software and or the Visitor Management System None of these features will be accessible or even visible if the license hasn t been registered Only the feature ordered will be included on a license RBH Access Technologies Inc Chapter 12 Program Groups Integra32 Registration C Program Filesirbh Integras2 Default SALES DEMO AU a To register the software input the following three pieces of information 1 Browse for and enter the path to the folder holding the license file license bin 2 Browse for and entry the path to the site folder to be registered Each site is registered separately if you hav
18. Mumber OVA IP Address Port Number IN This tab 1s only available 1f the CCTV module has been installed The information in this tab is only used to interface with a DVR There are two ways that this interface can be accomplished The first is by using ASCII messages M Send ASCII Message to DVR First select the camera number you want to display from DVR Then enter the DVR s IP address and Port Number associated with the camera you selected as you could be using more than one DVR this configuration is used by the History Reports DVR tab to playback video associated with a logged event This selection is only available if the optional license for the DVR Software has been purchased and installed Integra32 User s Guide RBH Access Technologies Inc 76 Chapter 5 Programming General Details LLTW Links OWA Name None Camera Information History Information Camera Number W FTZ Camera Pre Event Time Post Event Time fo Miri The second way the interface can be used 1s to associate with a specific DVR DVR are set up in the Database Screen under DVR First select a DVR for the pull down list under DVR Name Next configure the Camera Information Select a camera number indicate whether it s a PTZ camera or not and if it is enter a preset number if applicable Then set the History Information Set the Pre Event Time and the Post Event T
19. Operator Commands and it provides viewing of the status of the items that have been selected e g Access Points Input Points and Output Points a ae MA E a Access Inputs Outputs Panels reas Visitors a m TR Status Cardholders E P Reader 1 Locked Normal f 7 E A Reader 2 Locked Normal ee i Helen a Reader 3 Locked Normal sembpermanent E lA Reader 4 Locked Normal Show Report 3 a E Reader 5 Locked Normal Senn a A Reader 6 Locked Normal ieee Reader Y Locked Normal Reader E Locked Normal Status for items shown is in real time Items are updated as events change keeping the operator up to date Alarms Screen This screen appears in the same pane in place of the Status Screen From here alarms are acknowledged and cleared Dates Alarmmessage Operator 3 May 2006 08 38 36 Access point Forced entry alarm Instruction messages can be obtained from the Details of the alarm and actions taken can be noted there as well Integra32 User s Guide RBH Access Technologies Inc 10 Chapter 2 Getting to know Integra32 Event Log Screen This screen displays all system activity such as cardholder activity input activity output activity and panel activity All system messages are also displayed here 3 May 2006 08 32 39 Audit message Operator logged on 3 May 2006 08 39 06 Audit message Record changed Access Point Reader 1 3 May 2006 08 39 22 Audit message Record changed
20. Output PEF Access Points 4 32 Alam monitoring E E El Language The language the system will operate in for this operator is selected in the Language tab Operator Properties x General Database Monitor Language Select default language English ki 2 Portuguese Canadian French Spanish Chinese RBH Access Technologies Inc Integra32 User s Guide 29 Chapter 5 Programming Holidays Up to forty holidays can be assigned ae 4 Holidays Goo Fa Add Holiday ven Good Friday Can re Refresh vavaa Civi ds Civic 1 2 Delete Labour Day e Labo PE Properties ven Thanksgiving Day ven Than Christmas Break i hu Christmas Break You can edit create the name of a holiday and the date s of a holiday in the Holiday Properties You can Select a Date the holiday starts on and an End Date for the holiday Any date designated as a holiday will replace the regular day of the week for the day specified E g Good Friday 2 April 2010 as far as schedules are concerned this day will not be a Friday it will be H1 Start and end times can also be specified for the holidays In the example shown below the holiday starts on 24 December 2010 at noon Up until noon the day is Friday at noon the day becomes H1 The holiday remains until 10 00pm on 26 December 2010 when the day of the week changes from H1 to Sunday xl Haliday Description Christmas Break Start Date 12 24 2010 a 12 00 00 Pl E
21. PT N IE AA ASA AA ne PE re ee en en ene ee ae 102 RACE a PT ee rey A SA AAA PE rene en een AE 103 PRO TO a AS AAA PE eee en Ten Pon eee eae 104 REPORTS a e en aeRO ee 105 PIS RORY REPORT ae E aida 105 TDN Cet cts sa A nn tine dal sal cacti verte dr cn ao osos da Seen EET 106 REPOSAN Rd 106 Presta han loan T EEPE EA E EENE AERA tacts 106 TA 109 DATABASE REFOR Sidi aaa ida 110 A tiara E EE O eres casera tha na ecco aed eel AE 110 VISITOR REPORT Std ido iii 112 OPTION Sosa di 113 SNS TEM OPTIONS a a A NS cd 113 E T A MAA E NE A E E A E NA AN 113 DATO AR US 115 TOW ictal e EAE AEE EE EEE EEE EE acts TE E E EA EE liy SYSTEM MESSAGES airiai e a a a a a a a a a ea a a ga beeen aa ea 118 ACCESSPOINT ACTIVITY A A aa 119 MOTELES 1 A A A A A A A AA AS 119 A O tate hae E EA aeide aS taste etn tdlt ssa seta atassrease 119 N IVECO N ENG URANO TO 120 eMail CON OUNO OTE cost see kiosk ella es ado ol he y lla e aks aka aida Sd 120 CTS CVT AS aioe lca elas tesa aaa adios 121 A suas sceecaseseescsus seuecusacecuovesdsescanccnvecusedeacsesedesssuacteescatecssdonesseossueiseeretecastes 122 OTOBALLIN St daa 122 TOOLS a cti 123 BACKUP aa A A A iaa 123 RUANO Wa EE E O E E O EE EA TOE 123 COMMUTE TOFU CD EET E ia E E 124 RESTORE is 125 VOD CARDS pee meet a a E T a E TT AE T AA A 126 FINGER PRIN Tanon a O 127 QUERY FINGER PRINTAREADER des dt de e ede 129 BADGE TEMPLATE DE SONES 130 CARD CUSTOM P O teas tacsacssieladiation soap ieplastesea oleae Bed Aid Aiea 1
22. Programming Modes x General Modes Time outs Links Alarms CCT Advanced Options M Auto relock High security Deduct usage Facility code mode Digable forced entry e Report ATE First person delay Report door not open ATE Bypass OC e Report unknown format PC Decision Required Inhibit 1D Unlock schedule foo Hever Card PIN schedule foo Hever Auto Relock After a grant access the door locks again at the end of the unlock time With auto relock checked 1f the door closes before the unlock time expires then the door will lock when the door closes and won t wait until the timer expires Deduct Usage Readers selected to deduct usage will reduce the usage count of cards granted access 1f the cards usage count is less than 255 Card with a usage count of zero will not be granted access Usage count works per panel if the system is run offline Systems that are run online will have the usage count of a cardholder updated in all panels when any reader reduces that cardholder s count 2 This feature doesn t work in conjunction with PC Decision Required PC Decision Required will override Deduct Usage Disable Forced Entry If Forced Entry is disabled then opening the door without an access granted will not cause a Forced Entry alarm but instead will start the access granted sequence This is generally used on a door with a mechanical egress and no request to exit device I
23. Technologies Inc Integra32 User s Guide 129 Chapter 11 Tools Badge Template Designer ES Badge Template Designer i la EA File Help Di Bi e t je 1 5 2 0 2 5 3 0 3 5 1 Horizontal Card 2 Vertical Card 3 Horizontal ID 4 Vertical ID 5 Customized bo co Please select New or Open a template to edit The Badge Template Designer can create standard or customized badge sizes Select one of the five options available from the Create a new template button of the toolbar Templates can be saved and re opened 34 This selection is only available if the optional license for the Badging Software has been purchased and installed Integra32 User s Guide RBH Access Technologies Inc 130 Chapter 11 Tools leia File Help 0 4 as A 0 0 0 5 OO 05 1 0 15 2 0 25 3 0 aL Testi Front Side x Faste Insert Text Field Insert Photo Field Insert Signature Field Insert Finger Print Field Insert BarCode Field Insert Shape Field Save Template Save Template As lt LastName gt lt FirstName gt Properties Editing template Right clicking on the badge will bring up a menu list From here you can add a text photo fingerprint signature or barcode field Text fields can be static type in your own information or it can get data from a field in the database e g name or card number Photo fields can also be static so that you
24. Visited Checked In Checked Out I J ofo b bl 2 This selection is only available if the optional license for the Visitor Management System has been purchased and installed RBH Access Technologies Inc Integra32 User s Guide 97 Chapter 7 Visitor Manager The Last Name and First Name fields are mandatory fields and must have data before you can save the visitor while the NationalID field is optional All three of these fields are quick search fields Type data into the quick search field and hit Enter The quick search field will call up the record with matching data or will produce a list of record to choose from Card Number 1s also a quick search field and is ideal for calling up a record when a visitor is checking out ll Add Click Add to enter a new visitor Edit Click Edit to modify an existing visitor mi Save Click Save to save changes made be adding a new visitor or modifying an existing one Pa Delete Click Delete to permanently remove a visitor from the database Ki Cancel Click Cancel to exit edit mode and not save any changes made 4 Search Click Search to call up a search screen to look for a specific visitor Integra32 User s Guide RBH Access Technologies Inc 98 Chapter 7 Visitor Manager a Search al Es Search Field Lastname kd Look for Pence Employer Date of Birth Select the search field enter the search criteria
25. a rput Arm Neal z pput Disarm Armed Normal Input Armed Normal En Live nput Armed Normal nput En Play Armed Normal 4 H The following commands for Input points are available by right clicking the selected Input points Commands Arm Input Arm the input When an input is armed an alarm is generated if the input is violated In the case of a door opening an armed door generates an alarm 7 Disarm Input Disarm an input While an input is disarmed no alarm is generated when the input is violated In the case of a door opening the door while disarmed does not generate an alarm The system however will still generate and log a door opened event and report 1t to the Log Screen Live Select Live to display live video from the CCTV camera associated with the selected input point Play Play will bring up a DVR history selection screen so that video connected to an event for the chosen input point can be played back 10 This selection is only available if the optional license for the DVR Software has been purchased and installed l This selection is only available if the optional license for the DVR Software has been purchased and installed Integra32 User s Guide RBH Access Technologies Inc 16 Chapter 3 Monitor Screen Output Points Commands Clicking the Output Points button on the Command Toolbar depicts the status of output points on the Device Status Screen
26. been purchased and installed Integra32 User s Guide RBH Access Technologies Inc 8 Chapter 2 Getting to know Integra32 Help Help Press this button to get online help Database Screen The system is configured for a particular installation from this screen Setup and programming of hardware devices IRC 2000 and programming of all records such as access levels schedules and holidays are done here with the exception of cardholders Configure El Integradz System He Users Holidays H D Schedules 2 Areas a Messages E Networks Elsa Network 1 mE Panels 8 Panel 1 ER Access Points Epa Inputs Outputs 8 Output 1 Output 2 foe I a tout E 9 Output 6 Output 7 3 E Output ce Panel 2 ce Panel 3 H H Panel 4 Er Access Levels dida al M aster rbh Up to sixteen networks can be configured and up to thirty two panels can be configured for each Integra32 system These panels can be distributed across the sixteen networks as you like with no more than sixteen panels on any one network A maximum of thirty schedules each with up to eight periods can be added to the existing schedules Never and Always The system is capable of handling up to forty holidays and one hundred messages RBH Access Technologies Inc Integra32 User s Guide 9 Chapter 2 Getting to know Integra32 Device Status Screen This screen gives the operator control of the system through
27. can insert your own picture or logo or picture field where you can display the cardholder s image that is stored in the database or acquire the picture of the cardholder if a camera is installed on your computer Fingerprint fields can be added to the badge Signature fields can be added to the badge Barcode fields can be added to the badge A shape field can also be added to enhance your badge In the properties of the badge you can set the background colour of the badge you can also add a background picture o You can right click on a field to modify its properties or to delete it To use these options you may need optional hardware devices 3 To use these options you may need optional hardware devices 7 To use the Barcode field you need to install barcode fonts in your control panel which are available in the fonts Resources folder of your Integra CD RBH Access Technologies Inc Integra32 User s Guide 131 Chapter 11 Tools Card Custom Fields Integra32 AxiomLite Cardholders i x Z Wd e Edit Save Cancel Last name First name Initials Lardnumber A ee eee More Fields User Number User Numbers User Text 1 User Text 2 AA User Text 3 User Datel User Text 4 K User Text 5 E User Textb E Double click on a header while in the Edit Mode to change the name of the user field This change will be shown in the More Fields tab of every ca
28. e g Cardholder window RBH Access Technologies Inc Integra32 User s Guide 3 Chapter 2 Getting to know Integra32 Menu Options File File Options Links Tools Reporte Help amp Log Out ES Exit Use this menu to log in log out or to exit the Integra32 application om Log In amp Out Ctrl L An operator must be logged in to operate the system This ensures that all actions performed on the PC can be attributed to a particular operator Connect to Server i Login Name ibh v3 8 6 Password pen Server To log in enter your full login Name and password The default login name is rbh and default password is password Both Login Name and Password are not case sensitive An operator should log out when leaving the computer unattended or when finished his her shift Logging out protects the system against unauthorized access Exit Exit will shutdown the Integra32 System Client software Integra32 User s Guide RBH Access Technologies Inc 4 Chapter 2 Getting to know Integra32 Options File Options Links Tools Reports Help System Options E System Messages EH AP Activity Y M Configuration Use this menu option to customize user preferences through System Options or customize the System Messages that are displayed on the Status Screen and in the History Reports The Access Point Activity window is also enabled here Details of the Access Point Activity wind
29. in second minutes maximum 127 minutes The input must be tripped for this amount of time to cause an alarm If the input 1s cleared before the time expires then there won t be an alarm For General Purpose inputs additional programming is required under the Details tab General Details o a A CETV Links Alarms Circuit type Abort Delay INC 1 Resistor ls fse 7 Options Forced arm alarm e Report while armed e Report while disarmed Disarm during time group oz After Hours Integra32 User s Guide RBH Access Technologies Inc 70 Chapter 5 Programming Reporting or Non reporting Are messages from this input to be displayed on the Log Screen and logged Forced Arm Alarm or Not Forced Arm Alarm Forced Arm Alarm will force an input into alarm if it is armed while it is abnormal Disarm during Time Group Disarm the input during a schedule cctv AAA General Details CLT Links Alarms Camera Number AA oao OWA IP Address Port Humber IES ae This tab 1s only available 1f the CCTV module has been installed The information in this tab is only used to interface with a DVR There are two ways that this interface can be accomplished The first is by using ASCII messages M Send ASCII Message to DVR First select the camera number you want to display from DVR Then enter the DVR s IP address and Port Number associated w
30. occur when the message appears in the log screen e Then select an Alarm Schedule Causes an alarm when e Then you can select if required an instruction message for the alarm Message creation is described earlier M Show Video If camera assigned on DVR tab Check this box to have the DVR show the camera configured on the DVR tab for this input on configured Alarm M Show Video on Event Check this box to have the DVR show the camera configured on the DVR tab for this input on configured event Integra32 User s Guide RBH Access Technologies Inc 14 Chapter 5 Programming Outputs ae le Outputs General The Description and Type of the output can be changed programmed in the General tab e The output type can be General Purpose Lock for Reader A Lock for Reader B Handicap for Reader A Handicap for Reader B Alarm Shunt A Alarm Shunt B Modem Power Details On State Energized z Output State On during time group 02 After Hours M Report to PC Choose Energized De energized On State and select a schedule for Output State On During Time Group from the Details tab Also select the option of Report to PC if it is needed Output State On During Time Group and Report to PC are programmable for general purpose outputs only RBH Access Technologies Inc Integra32 User s Guide 19 Chapter 5 Programming CCTV General Details CLTY Links Camera
31. option can unlock or lock access points with a double grant access Two consecutive grant accesses by the same card can toggle the lock unlock mode of an access point High Security Privilege 4 Cards with this option will be granted access on doors in high security mode As well high security mode on a door can be toggled with four consecutive grant accesses Link Execute Privilege 3 5 Cards with this option can execute Global Links with either three or five consecutive Access Granteds Three consecutive Access Granteds can be programmed with a different link then five consecutive Access Granteds Extended Unlock Time Cards with this option will use the Extended Unlock Time instead of the regular Unlock Time Disabled Cards with this option will activate the Handicap Output associated with the access point The Handicap Output follows the activation of the Lock Output by a short delay and is used to trigger a door operator to open the door Ignore Auto Void Cards with this option will ignore Auto void if selected any in system settings Cards Up to twenty cards can be added per cardholder New cards can be added for an existing cardholder with the Add button All the cards assigned to a cardholder can be seen on the left hand window of the Cardholder Screen when a cardholder is selected The card number and description of the card are put into this window Click the Add button to add a card to the cardholder Enter the ca
32. outs Links Alarms CCT Advanced Entering rea W Standard AFE Enabled Mone E siting rea None Exit Reader Installed e AP Activity Access Requested Access Granted Access Denied Chapter 5 Programming Lancel Standard APB Enabled The check box is used to turn on antipassback Soft antipassback will still grant access even though APB has been violated hard APB will not Global Local Antipassback NIZ For Global Antipassback to work the Integra32TM system must be online and PC Decision Required must be turned on in the Modes tab of the Reader Properties window for all of the appropriate readers otherwise the panel will default to Local Antipassback within an IRC 2000 Global Antipassback allows a cardholder s area to be reset cleared meaning they are not logged into any area With Local Antipassback the cardholder is either In or Out never neither always one or the other Local Antipassback may be used with or without the Exit Reader Interface If the Exit Reader Interface is not used when Local Antipassback is configured then either the A side or the B side reader port not both needs to have its TAM terminal grounded The side with the grounded TAM terminal will be the Out reader and the side without will be the In reader 17 Antipassback tracked across multiple IRC 2000s is called Global Antipassback S Antipassba
33. panel type is chosen when the new panel is added and cannot be edited later Enable If the enable check box is not checked then the panel will not be shown in the status screen All Access Point Inputs and Outputs under that panel will also be disabled Disabled items are still in the database but are not considered to be part of the system Keypads Panel Properties Pririt Cancel Apply Address This is the address of the keypad in the Bosch system 1 15 Only five of the possible fifteen keypads can be selected for use with the PC100 Name Enter here a description or name of the keypad to be shown in the Integra32 system Emulated Check this box if the Integra32 system will be emulating this keypad and leave it unchecked to monitor an existing keypad Signals from an emulated keypad will be the same as signals from an existing keypad therefore to the Bosch system there is no difference between an emulated keypad and an existing keypad RBH Access Technologies Inc Integra32 User s Guide 49 Chapter 5 Programming Pin Codes Panel Properties Select either 4 Digit Pin Codes or 6 Digit Pin Codes Pin Codes Enter the four or six digits of each PIN code These PIN codes must match PIN codes programmed into the Bosch system in order for commands from the emulated keypads to affect the Bosch system Only five of the possible two hundred PIN codes may be entered here Pin Code Name
34. schedule or delete a schedule you will be asked if the changes are to be downloaded and the panel initialized now or will it be done later Confirm Change x Schedule file must be downloaded to all panels and all panels must P be initialized Download now Integra32 User s Guide RBH Access Technologies Inc 32 Areas Chapter 5 Programming al Areas e Main Office M Add Area Refresh o 70 lif Sales 7 Delete Warehouse oP Warehi BRE Properties lif Computer Room eli Computer Room In the Area Properties window the name of the area is entered Access points from which a cardholder can enter or exit the area define the actual area A Clear Area time can also be entered here As well an input and an output both general purpose can be chosen To print out a report of all the cardholders in the area simply put the input into alarm The output will be turned on when there are no cardholders in the area 1t must be turned off manually operator command rea Properties x Description de IN ew Area Clear rea Input Output RBH Access Technologies Inc Integra32 User s Guide 33 Chapter 5 Programming Messages a a Messages a Call det Add Message e Call Police Low Remeh 2 Low Temperature TER Poa E Aa Smoke Detector oc Smoke E Fas Delete gt Flood Alarm Flood Al E Properties Panel Trouble af Panel Tr
35. the operator can enter data concerning anything that the visitor brought with them to the site To print a receipt for these assets click on the Receipt button If there is any information entered under a visitor s asset then a reminder will pop up when the visitor checks out After the visitor has checked out this asset data is deleted Integra32 User s Guide RBH Access Technologies Inc 102 Chapter 7 Visitor Manager Track E Integra32 AxiomLite Security System Yisitor a E A z Ss a a Add Edit Save Delete Gantel Search CheckIn Check Out Receipt Track E mail Lastname Firstname MationallC Card Number jo Photo General Track visiting Lastname 2 Firstname PASTE Th Employee Card fo Last Ghecked In Last Visited Checked In Checked Out I J ofo b Dl The Track tab will display the access points that the visitor has been granted access to since their check in time Simply click on the track button to display the information Only visitor that are checked in can be tracked If the visitor has checked out you can get information on where they have been from the Visitor Reports RBH Access Technologies Inc Integra32 User s Guide 103 Chapter 7 Visitor Manager Photo Integra32 AxiomLite Security System Visitor x El A 4 PA al a L a Si meel Search CheckIn Check Out Receipt Track E mail A En Add Edit Save Delete Lastna
36. 2000 or URC2000 Description Online E Panel 2 Online lt lt Version PC100 Summit or Risco Group Integra32 User s Guide 18 Description Panel 1 Online BR Panel 2 Online Download P Keypads Links Pincodes All Files PC100 Bosch RBH Access Technologies Inc Chapter 3 Monitor Screen Commands IRC2000 amp URC2000 The following commands for panels are available by right clicking the selected IRC2000 and or URC2000 panel s Version The Version queries all or selected IRC 2000 and or URC2000 for the firmware version they are running The version number will be displayed on the Log Screen Set Date Time Click on the Set Date Time to launch the Set Panel Date Time Screen e The Get Local button is used to retrieve the current date and time settings from the PC s internal clock e The Set button is used to upload the selected Date Time settings to the selected IRC 2000 and URC2000 controllers e The Close button is used to close the Set Panel Date Time Window Get Date Time This command queries the controller for its current date and time and displays it on the Log Screen Download The Download function allows the operator to manually repopulate the IRC 2000 and or URC2000 memory from the database on the server Select any of the listed files to download or select the All Files option to download all files Download messages are posted to the lo
37. 32 CARD IMPOR a a we 133 COMI onre MPOT UU rrira A es 133 COMPLETE TNE COREA TON a AAN TETEE ad CG a RE OO E O EEN seit 139 PRUE THOT A A A A A AA aid 142 View LOE IU AL AS EA NE AA A el tee A id 143 PROGRAM GROUPS id ii 144 INTEGRA32 ANTAS A totototo tototo tototo Lo nor LIEDES LIEDES EIE ESEI E EIEI ES EIES EI EIEI EI E EIE EIEEEI ESE E EIE E Eann 144 Intega32 User s Guide RBH Access Technologies Inc Table of Contents Integra32 Data AI AN 145 Integra32 Database Maintenance cccccccccscscsscssessssseevsvsvsvscueussvsvseseuecsvsvsesensvsvavsesesevsvavasiesevsvavasueusvsvavasacuseseans 145 Integra32 Firmware Upgrade RN 145 Integra32 Security SS SII A A A pal are irite iaie 147 Ime oras Sue COn OUTOU sata aoe rare osea ste 148 MES RECSA Ore hte acer e osea e 148 CCTOSSAR Vina A E AA ANA A LES 150 LICENSE WARRANTY A dio 151 INI A NA 152 READER COMMENTS usina ANA AAA al 155 RBH Access Technologies Inc Intega32 User s Guide About This Guide About This Guide This guide documents how to install and use the Integra32 Security Management System as developed by RBH Access Technologies Inc The Integra32 system represents the latest in access control technology specifically designed for the smaller application Its intuitive graphical interface allows users to take advantage of the power of the Integra32 with a minimal amount of training Read this guide if you are An operator who monitors security and access
38. 4 May 006 End Cardnumber Expiry Date 1 Jan 038 Access Level No ACCESS le Multi Cards utility can add multiple cards in a sequence in the cardholder window as well as download them to the panel on the basis of the Access Level assigned to them e Putin the Start and End card number e Assign the Expiry date if any e Assign the Access Level from the drop down menu of the Access Levels configured in your system Integra32 User s Guide RBH Access Technologies Inc 86 Chapter 6 Cardholders Multi Cards x Start Cardnumber Actyation Date 39099 29 Mar 2005 E End Cardnumber Expiry Date 29500 1 Jan 2038 Access Level No Access 01 Master U2 Accounting 03 Sales O4 Warehouse 05 Shipping O6 Manager e Click on Start button to add the cards Multi Cards xj Start Cardnumber Actyation Date 39099 29 Mar 2005 E End Cardnumber Expiry Date 29500 1 Jan 2038 Access Level 04 Warehouse Card Number 39105 4dded Card Number 39106 Added Card Number 39107 Added Card Number 39108 Added Card Number 39109 Added Card Number 39110 Added Card Number 39111 Added Card Number 39112 Added Card Humber 39113 Added Card Number 39114 Added Card Number 39115 Added Card Number 39116 Added Card Number 39117 Added RBH Access Technologies Inc Integra32 User s Guide 87 Chapter 6 Cardholders F Print E C Enrollment unit Reade
39. Access Point Reader 6 3 May 2006 08 39 10 Access point Forced entry alarm Reader 1 Panel 1 3 May 2006 08 38 36 Access point Forced entry alarm Reader 6 Panel 3 All the messages shown here are also saved to History and can be retrieved through History Reports RBH Access Technologies Inc Integra32 User s Guide 11 Chapter 3 Monitor Screen Chapter 3 Command Screen From the Command Screen the operator can issue commands as well as view status Commands can be sent to access points inputs outputs and panels Areas can be cleared and cardholders can have their area set or cleared Alarms cab be acknowledged and cleared a D gt i MA E E Sempermanent ACCESS Inputs Outputs Panels reas Cardholders a E St Reader 1 Unlocked Normal E Reader 2 Locked Normal a Reader 3 Locked Normal i gi Reader 4 Locked DHO Warning E E Reader 5 Locked Normal A Reader 6 Locked Normal A Reader 7 Locked Normal A Reader 8 Locked Normal 4 d Device Status Clicking on the Status button on the toolbar of the main screen will change the Alarms Screen to the Device Status Screen From the Device Status Screen the operator can lock and unlock doors arm and disarm inputs and switch on and off outputs The status is displayed in real time but only for those devices that have reporting enabled The operator can turn messages off for certain events and no history will be logged for those events but
40. CCTV camera associated with the selected alarm event 1 This selection is only available if the optional license for the DVR Software has been purchased and installed Integra32 User s Guide RBH Access Technologies Inc 26 Chapter 5 Programming Chapter 5 Programming Click on the sign to expand the tree view of your Integra32 system in the Database Screen Click on the sign to compress it Double clicking the description will either expand or compress the view depending on the sign associated with the text Items that do not have a sign or associated with them will take you to their properties when they are double clicked Integra32 System fe Users DS 4 Holidays 4 0 Schedules EI reas E Messages El 238 Networks A Access Levels L Right clicking on the different selections will bring up small menus From these menus you can add delete or go to properties for the selected item Right clicking the access point the input or the output will not bring up a menu there are no options to select but will expand the tree view instead Integra32 Database Users The Integra32 system comes with user rbh by default with password password Additional Users Operators can be added and configured the in the Database Screen E E Users a AF Bob atesi AE Hans ga i Haze X Delete aa CF rbh E perties E AE supe d RBH Access Technologies Inc Integra32 User s Guid
41. Integra32 Integrated Alarm Monitoring and Access Control USER MANUAL Copyright Notice Copyright 1995 2010 by RBH Access Technologies Inc All rights reserved Worldwide Printed in Canada This publication has been provided pursuant to an agreement containing restrictions on its use No part of this book may be copied or distributed transmitted stored in a retrieval system or translated into any human or computer language in any form or by any means electronic mechanical magnetic manual or otherwise or disclosed to third parties without the express written consent of RBH Access Technologies Inc Brampton Ontario Canada Trademark Integra32 is the trademark of RBH Access Technologies Inc Windows is a trademark of Microsoft Corporation All other product names mentioned herein are the property of their respective owners Use of a term in this book should not be regarded as affecting the validity of any trademark or service mark Disclaimer This book is provided as is without warranty of any kind either express or implied including but not limited to performance merchantability or fitness for any particular purpose Neither RBH Access Technologies Inc nor its dealers or distributors shall be liable to any person or entity with respect to any liability loss or damage caused or alleged to have been caused directly or indirectly by this information Further RBH Access Technologies Inc reserves the rig
42. Name Enter here a description or name for each PIN code RBH Access Technologies Inc Integra32 User s Guide 57 Chapter 5 Programming Links Panel Properties x 1 coo Ao Event Select from a pull down list the triggering event Device ID Choose the appropriate device to execute the selected command from a pull down for the selected event Card Enter the card number if applicable that will trigger the selected command when it is associated with the chosen device and selected event e g execute the command when card 1234 is granted access at reader 1 Command Select the command to be executed on the chosen keypad from a pull down list Arm Keypad Disarm Keypad or Arm Perimeter Keypad Choose which keypad the command is to be executed on Pin Code Select a valid PIN code The command will be executed as though this PIN code had been entered Integra32 User s Guide RBH Access Technologies Inc 98 Chapter 5 Programming Access Points Access Points Description To change the default description simply type over it Input amp Output Configuration This section of the tab tells you which inputs and outputs are assigned to the access point Enable If the enable check box is not checked then the access point will not be shown in the status screen and will not be considered as part of the system RBH Access Technologies Inc Integra32 User s Guide 99 Chapter 5
43. Program FilesirbhiIntegras2 Default Integra32 User s Guide 134 RBH Access Technologies Inc Chapter 11 Tools Then select the appropriate destination fields for the corresponding source fields e g select Surname for Field I and Firstname for Field 2 depending on the data in the text file Import Wizard E List Source Field Text File Destination Field 4xUserLT mdb Field 1 Surname Field 2 Firstname Field 3 CardWNumber Field 4 Field 5 Field 6 Field 7 Firstname Field 3 Initials Street Field 9 Cit Field 10 hd Help Cancel lt Back Mext gt Finish Click Next to continue RBH Access Technologies Inc Integra32 User s Guide 135 Chapter 11 Tools Import from a SQL file Import Wizard l The wizard will help you to enter bulk data in the card holder table Cards can either be imported From an external text File or M5 SOL Server Local machine should hawe SGL Server running or SQL Client installed Import cards From a text file f Imports Cards from SOL Server Help Cancel Back Meck gt Finish Click New to input the connection string Import Wizard i Connection String Test Connection Table Query Integra Folder Help Integra32 User s Guide 136 RBH Access Technologies Inc Chapter 11 Tools Use the pull down to select the server Enter the User Id and password Then select the specific database o
44. Risco Group ME Panels fy Panel 1 mE Panels cel bat SS Panel 1 E Inf Fe Properties ta Pc1o0 a pane Access Levels Delete ane 3 DYR ER E Panel 4 EE Properties IRC2000 or URC2000 General Panel ee xi General Reader Options Site codes Alarms Code Reader Links Address Description Panel Fanel type iRc2000 W Enabled Cancel RBH Access Technologies Inc Integra32 User s Guide 41 Chapter 5 Programming Address The address is selected at the time creation and cannot be edited later Description To change the default description simply type over it Panel Type The panel type is chosen when the new panel is added and cannot be edited later Enable If the enable check box is not checked then the panel will not be shown in the status screen All Access Point Inputs and Outputs under that panel will also be disabled Disabled items are still in the database but are not considered to be part of the system Reader Options ee a xi General Header Options o k Site codes Alarms Code Reader Links Card Formats f Weigand Mag Strip 39 bit Rantech SF FL Card 40 bit Farpoint 50 bit RBH Interlock Card Format This is where the card format is selected only a limited number of formats are supported list provided Interlock With Interlock checked only one of the two doors on the one p
45. Use this option to turn on off the Facility Code mode when the system checks only the Facility Code portion of the card code All cards with valid Facility Codes will be granted access This feature is typically used when the system is being configured for the first time and the cardholder information is not entered in the database Interlock With this feature enabled a door will not be unlocked if the other door is opened The open door must be closed before the other door will grant access View Mode Select this option to view all the modes available and their status Live Select Live to display live video from the CCTV camera associated with the selected access point Play Play will bring up a DVR history selection screen so that video connected to an event for the chosen access point can be played back This selection is only available if the optional license for the DVR Software has been purchased and installed This selection is only available if the optional license for the DVR Software has been purchased and installed RBH Access Technologies Inc Integra32 User s Guide 15 Chapter 3 Monitor Screen Input Points Commands Clicking the Input Points button on the Command Toolbar depicts the status of input points on the Device Status Screen 5 C HE iW o BA E E Sempermanent 7 Access Inputs Outputs Panels Areas Cardholders i E ae nput 3 am Normal Ma AM A II AA e e Nae ee Amed Homa a Pe ee ec eens
46. a Panel 2 aa Panel 3 HY Access Points e Inputs Y eS E de Elevator roperties 2 Delete H pared E JO add Elevator fay Panel 5 The URC2000 Elevator Control can control up to two elevator cabs and thirty two floors You can split the thirty two floors between the two doors any way you like Add Elevator al ES Description New Elevator Reader Available ltemz Selected ltemz Access Points used for elevator control will have all the standard functionality of regular Access Points except for Antipassback and Interlock and unlocking these Access Point will only affect the outputs assigned to the URC2000 controller and not the floor outputs RBH Access Technologies Inc Integra32 User s Guide 79 Chapter 5 Programming Add Elevator O xi Elevators Description Cab A Reader Reader 5 a Available lkems Description 1t Floor Cab B 2nd Floor Cab E 31d Floor Cab E 4th Floor Cab B Sth Floor Cab B bth Floor Cab B th Floor Cab B oth Floor Cab E Sth Floor Cab E 10th Floor Cab E 11th Floor Cab E 12th Floor Cab B Selected Items Description Tst Floor Cab end Floor Cab 4 ad Floor Cab A 4th Floor Cab 4 Bth Floor Cab A bth Floor Cab 4 th Floor Cab A oth Floor Cab A Sth Floor Cab A 10th Floor Cab A 11th Floor Cab 4 12th Floor Cab A OR Cancel Change the Description select a reader and for that reader determine which outputs floo
47. abate eden aata dt 21 VISITORS A A ad 22 EPS ae ae 22 KEYPAD COMMANDS o ao 23 COMAS a ida a ios its tia Roa 23 ACARMS SCREEN aeea a A E allcsuiceis 24 ACKNOWLEDGE UNACKNOWLEDGE CLEAR cccccscccescccecccueccecceuceeueceeeceeucseuesueceeecseusseeseeeceusesuseseeeceuncseeceeseusess 24 PETAR ELE AS scada 24 PROGRAVMIMITA Goa A cda 27 INTEGRAS 2 DATABASE aare asec cea waa b eh eka pa ab aie Rhea ALAS ca eae RE eas 27 UTS OVS hte se sitar dada tots Baste A RT 27 ONO IN EE T E T N A O OE 30 SCHEGUIOS AAA A AA A SA AR tee tented a dabty techs TIAS 31 FG AI A E E AATE EAEE ER T NEEE O O EA EAT 33 MESAP A E EEE O a O E 34 NEO o aaa a aaa 35 Pane osrin aaa RS a 4 ACCESS T SA dd a hak ied o ol ae cat O a 59 UTA A ae A E II 70 OPUS a A A dd 73 E A AA 79 FOON GOUDSE ARA A A cai l AC AYN gh LE E T E E TE E EE E EEE E A TA 82 CARDHOLDER Sacra aid 84 PIEEDS AND OPTIONS a asas 85 IVETE COTS ca a A alee sete tena aa A A E A A ee SO RBH Access Technologies Inc Intega32 User s Guide Table of Contents E AAA EN Re OTE A OPT ROE OATS EM ON ACERS PATENT PEER RON nae TE BES PETE ROAD ON AEN A nee 5S EC DA alec eevee ee sede ale oer peed ias 89 GARDAOLDERS TAD oaie E EE R nee eo 90 RR RATON 90 LIO A ET E A den A ETT T AE TETA A 93 POT OD eked aac dsd prota dan talca dond ce cava 94 Noves TOD datos darse os deal a dores 95 Morella Tao dra al drenan dopo leen 96 VISITOR MANAGER lt a a cdas 97 ENERO A AS ROS 100 CTED Ss AA SA AA SAS 101 ASS SS
48. ader 6 Set Mode High Security E Reader 7 Reset Mode P AFE Enabled E E Reader 8 View Mades Facility Code ie Interlock A Play The following commands for Access points are available by right clicking the selected Access points Commands Y Grant Access Unlock the access point for the duration of the access point Unlock Time This command has the same effect on an access point as presenting a valid card Lock Lock an access point or access point group on a permanent semi permanent or timed basis Unlock Unlock an access point or access point group on a permanent semi permanent or timed basis Set Mode The access point has several operating modes that are normally controlled by the scheduler The operator can override the scheduler and manually control these modes Integra32 User s Guide RBH Access Technologies Inc 14 Chapter 3 Monitor Screen Reset Mode Reset Mode button is used to turn off the option turned on in Set mode High Security In High Security mode only cards with high security privileges may gain access at this access point APB Enabled Antipassback is an access control feature that prevents cardholders misuse by putting certain restrictions on the use of their cards When the Antipassback feature is enabled cardholders must present their card for entry to and exit from all areas Antipassback prevents a cardholder from using his her card twice at the same access point Facility Code
49. amages of any kind including special indirect or consequential damages arising out of or resulting from any program services or materials made available hereunder or the or the modification thereof Notice 1 02 RBH Access Technologies Inc makes no claim or warranty with respect to the fitness of any product or software for a specific application and assumes no responsibility for installation This warranty is in lieu of all other warranties expressed or implied No representative or agent of RBH Access Technologies Inc may make any other claims to the fitness of any product for any application RBH Access Technologies Inc Integra32 User s Guide 151 Index Index A About This Guide Access Levels Access Point Activity Access Points Advanced Alarms CCTV Links Modes Time Outs Access Points Commands Acknowledge Acknowledge Unacknowledge Clear Action Messages Activate Card When Visitor Checks In Alarm Details Alarm Screen Alarm sounds Alarms Toolbar Button Antipassback AP Activity Toolbar Button Area and Cardholder Commands Areas Arm Keypad Auto void cards Auto Backup Auto Relock B Backup Badge Options Badge Template Designer C Card PIN Schedule Card Custom Fields Card Format Card Import Utility Cardholders Cards More Fields Tab Options Photo Tab Profile Tab Type Cardholders Toolbar Button Check In Check Out Clear Clear Log Integra32 User s Guide 152 82 69 119 67 64
50. and click search The results of the search will be posted in the lower half of the screen Check In Click Check In to have the visitor check in to the system Check Out Click Check Out to have the visitor check out of the system Track Click Track to display the access points that the visitor has been granted access to while checked in Receipt Click Receipt to print a receipt for a visitor s assets EMail Click on E Mail to send an email to the cardholder being visited For this to work the senders email information must be configured in VM Configuration under eMail Configuration and the being visited cardholder s Profile Tab must have an email address RBH Access Technologies Inc Integra32 User s Guide 99 Chapter 7 Visitor Manager General E Integra32 AxiomLite Security System Yisitor o iol xj 8 k rs gt ar a a E B Add Edit Save Delete Cancel Search EheckIn Gheck Out Receipt Track E mail Lastname Firstname NationallD Card Number jo Personal Information Reason to Visit Address Date of Birth City P Phone state Ena Country Employer Postal Code Time allotted fo Hours Notes visiting Lastname Firstname Hc SULT Employee Card jo Last Checked In Last Visited Checked In Checked Out Doro b bl Personal Information data is optional and specific to the visitor and not to the card Select who is being visited by clicking on the browse butto
51. anel may be opened at a time If one door is open then access will not be granted at the other door until the first door is closed Integra32 User s Guide RBH Access Technologies Inc 42 Chapter 5 Programming Site Codes Under the Site Codes tab the facility code to be used by the IRC 2000 is entered Each IRC 2000 panel will support up to five facility site codes Leading zeros are not required when entering a site codes even though the display does show them Panel 1 ay i 04000 Pad os Y P M RBH Access Technologies Inc Integra32 User s Guide 43 Chapter 5 Programming Alarms Under the Alarms tab the schedules are set for when Panel Online and Panel Offline cause an alarm An instruction message can be assigned to these alarms as well from this tab Instruction messages are created elsewhere General Reader Options Site codes Alarms Code Reader Links Baire Alarm schedule 00 Hever Instructions y Code Reader Links Code reader links can be linked to one or multiple inputs outputs and access points on a local basis A single access code with a card read is capable of invoking different links dependent on which access point it is presented at This linking is done at the controller level without the Host PC online A combination card reader and keypad is needed to utilize this function The programmed link is executed for the appropriate key code after a grant acces
52. anted 00 Never Access Denied 00 Never Forced Entry fon Never Door Held Open i Door Not Oper Restore Input Abnormal Input Restore Input Alarm Input Trouble Cancel To reset the password connect the panel directly to the Integra32 system and execute a full download to the panel Integra32 User s Guide RBH Access Technologies Inc 38 Chapter 5 Programming Ethernet Connect The controller network RC 2000 is connected to the PC through a standard Ethernet network Network Properties TCPAPNewok SSO p 132 168 1 128 For an Ethernet connection to work TCP must be installed on your computer Enter the specific address and proper port value for the Ethernet interface assigned to the network Enter a port value of which must match programming of Interface RBH Access Technologies Inc Integra32 User s Guide 39 Chapter 5 Programming Advanced Time Zone Difference If a network is located in an area within a different time zone you can set the difference here Set the number of hours either ahead or behind of the time where the server is located Network Properties Integra32 User s Guide RBH Access Technologies Inc 40 Chapter 5 Programming Panels Up to thirty two panels in total can be connected to the Integra32 system Add Panel Add PC100 F Bosch Add Panel IREZ2000 Refresh DSC Access Les Add PCO P UACZ000 So Sumt one Refresh URC2000 Elevator
53. art 24 Apr 2006 12 00 00 M T izi Bepon End 24 Apr 2006 11 59 59 PM Select readers default All I Readers E If Access Denied Cardholders Department iW Access Granted fal E E i Cardholder Action C Enty reader 2 IY Access Requested Exit reader e Select the Start and End Date and Time for the time period you want to preview the report for If the report is to cover only specific hours each day then check Daily Report so that the Start and End Time will be applied each day e Click the Select Readers button to select the readers you want on this report to preview or print All readers will be shown by default e Click the Cardholders button to select cardholders for your report All cardholders are selected by default e The user can customize the report by clicking in the checkboxes for Access Denied Access Granted Cardholder Action and Access Requested These selections will determine which messages are to be reported on e Click the Preview button to preview the customized cardholder s report Radio buttons Select one of Entry Reader Exit Reader or Both Readers are exit readers if they are connected to the Out Reader side of an Exit Reader Module or if their TAM terminal is grounded IRC2000 4 5 boards Otherwise they are entry readers this includes all readers on IRC2000 3 2 boards Entry reader Exit reader Both RBH Access Technologies Inc Integra32 User s Guide 107
54. cess Point Activity By checking this box you enable the automatic displaying of the Access Point Activity window when the selected event s occur at the access point Often this is used with a CCTV system for video verification of access Multiple readers may be select to be displayed with this window Only the last event is displayed though all previous displays are deleted AAA olas Grant access A Reader Number E Grant Access Grant access will grant access at the reader currently shown in the Reader box of the Access Point Activity window Note The above window is automatically displayed only if Access Point Activity is turned on either from the Options menu or on the main screen toolbar File Options Links Tools Reporte Help System Options cH Ez o EH Lo System Messages 2 AP Activity Cards Visitors DVR Help Y M Configuration RBH Access Technologies Inc Integra32 User s Guide 69 Chapter 5 Programming Inputs E Inputs General From General tab the user can change the description of the input The Type of input is also chosen here e The input type can be General Purpose RTE for Reader A RTE for Reader B Door Contact for Reader A Door Contact for Reader B Details Select the Circuit type and Abort Delay under the Details tab e Inputs can be Normally Open or Normally Closed One resister Two resister or No resister e Abort Delay is set
55. cess points with a keypad Type There are currently only two card types to choose from normal and visitor Normal cards are for your regular permanent cardholders while visitor cards are for a group of continually changing cardholders These cardholders are people who only need a card for a short period of time they use the card while they are on site and then hand it back in when they leave Options Choose from the six options available 1f required Unlock Privilege High Security Privilege Link Execute Privilege Extended Unlock Time and Handicap Ignore Auto Void Ignore Antipassback Cards that are given this option will bypass antipassback checks when presented to a reader This option can not be independently selected but is given to a cardholder that has been given Unlock or High Security Privilege Date is displayed in the format selected under Windows Control Panel Regional Settings Properties Date If a two digit year was chosen then it will be displayed in that form here 2 Date is displayed in the format selected under Windows Control Panel Regional Settings Properties Date If a two digit year was chosen then it will be displayed in that form here 2 This selection is only available if the optional license for the Visitor Management System has been purchased and installed RBH Access Technologies Inc Integra32 User s Guide 91 Chapter 6 Cardholders Unlock Privilege 2 Cards with this
56. ck tracked on one side of a panel RC 2000 is called Local Antipassback RBH Access Technologies Inc Integra32 User s Guide 67 Chapter 5 Programming Entering Area amp Exiting Area An Entering Area must be selected for APB to work Selecting only an Entering Area will setup Reader APB In Reader APB the Entering Area is compared to the cardholder s current location If they match there is an APB violation By adding an Exiting Area you setup Area APB Area APB not only check that the area the cardholder is entering isn t the area they are in but also verifies that the area they are exiting is the area they currently are in providing a higher level of APB APB Access Points work well with Exit Reader Interfaces The In reader uses the configuration of Entering Area and Exiting Area as programmed while the Out reader uses the inverse The Out reader gets its Entering Area from the data programmed into Exiting Area and vice versa Out Reader Install NIZ Selection of this option will configure the system to allow separate Global links for the In reader as for the Out reader The Exit Reader Interface module is used to connect two readers to a single reader port providing both In and Out readers To use the Exit Reader Interface module the IRC2000 must be running firmware 100 or higher Integra32 User s Guide RBH Access Technologies Inc 68 Chapter 5 Programming Ac
57. cture of the cardholder in the Photo tab or you can acquire a cardholder s image The picture is then saved in the Integra32 Images folder You can select or print one of the already saved templates for the cardholder in this tab if the badging option is part of the software 5 Integra32 AxiomLite Cardholders pi a ao A g Edit Cancel Delete Search Multi Cards F Print Receipt Last name First name Initials Cardnumber Dough i onathan D Cards Profile Photo Notes More Fields z FOES El Card Expiry Date 01 Jan 2038 Picture File 2 _ Signature File 1 NE Fi Signature File 2 Use the Card Front EX and Card Back buttons to view both sides of the badge Integra32 User s Guide RBH Access Technologies Inc 94 Chapter 6 Cardholders Notes Tab Any other relevant information concerning a cardholder can be saved under the Notes tab Integra32 AxiomLite Cardholders E o xXx Ala L Mew Edit Cancel Delete Search Multi Cards F Print Receipt Last name First name Initials Cardnumber Dough Jonathan D Notes entered here can be displayed in Access Point Activity window when it is expanded to show More RBH Access Technologies Inc Integra32 User s Guide 95 Chapter 6 Cardholders More Fields Tab Any additional information required for cardholders can be saved in More Fields tab The user can rename the fields under this tab by ri
58. d drd Sth amp 10th F 00 Never 2nd 4th amp 12th Floor 00 Never 2nd 31d 6th Sth amp 1 04 Mon Fri 38 00arn 5 00 pri nd 4th th amp oth F 00 Never 2nd drd Sth amp 10th F 00 Hever 2nd 4th amp 12th Floor 00 Never 2nd 31d 6th Sth 1100 Newer U2 Mon Fri 30arn 5 30 pri U3 After Hours 04 Mon Fri 8 00am 5 00prm i The schedule of any Floor Group can be changed to any schedule as long as no more than four schedules are changed from Never If multiple Floor Groups that are given schedules have floors in common than the cardholder will have access to those floors 1f any schedule allows it RBH Access Technologies Inc Integra32 User s Guide 83 Chapter 6 Cardholders Chapter 6 Cardholders Cardholders are entered edited by clicking the Cards button from the toolbar of the Main Integra32 AxiomLite Cardholders f x File New Last name x dc UE ig Delete Search Multi Cards F Print Receipt Initials Cardnumber Dough Jonathan Il D 30292 Access level Activation date 16 04 2009 A Deactivation date Usage Count mo a 2 status FIN Code Type i Ignore Antipassback Ignore Auta amd i Unlock Privilege 2 F High Security Privilege 4 Link Execute Privilege 345 Extended unlock time Disabled El Add Edit Remove Copy Integra32 User s Guide 84 RBH Access Technologies Inc Chapter 6 Cardholders
59. der 13 Panel HarpnderKam 25 Mar 2005104828 an Access artedCad Reader 13 Panel Mesa Denaro ____ 25 Mar 2005 1047 26 en Access rrtedCad Reader 13 Panel Mesa Dema ____ 25 Mar 2005104603 an Access artedCad Reader 13 Panel Mesa Denaro ____ 25 Mar 2005 104858 am Access artet Cad Reader 13 Parel 7 Harper Kam 25 Mar 2005 104807 en Access ertedCard Reader 13 Panel Mesa Denaro ____ 25 Mar 2005105229 en Access ertedCad Reader 13 Panel ChatesSone ___ 29 Mar 2006 105232 aml Access ertedCad Reader 13 Penel7 Metsa Demers 29 Mar 2005 105522 an Access ertedCad Reader 13 Penel7 Steve Tan _ 25 Mar 2006 105540 aml Access ertedCad Reader 13 Penel7 Metsa Demas __ 25Mar2005 105554 aml Access ertedCad Reader 13 Penel7 Chafes Score __ a2 10562 on accessgaredCad Read 12 Parl7 Meraner TO ee EE ee ed ee D J 171 Fi 7 Double click the line that has a Camera sign with the event that is to be played back 27 This selection is only available if the optional license for the DVR Software has been purchased and installed RBH Access Technologies Inc Integra32 User s Guide 109 Chapter 8 Reports Database Reports Select Database Reports from the Reports menu to launch the following window where the user has the option of selecting from many database reports available Create Database Report xj Select the report from following list Access Levels Report Access P
60. dex Timed Command Toolbar Buttons Tools Track Visitor U Unacknowledge Unlock Privilege Unlock Schedule URC2000 Properties URC2000 with ELV Usage Count User Fields Visitors Integra32 User s Guide 154 13 5 123 103 104 26 92 62 41 46 91 121 User Options Users V Version Visitor Assets Visitor Manager Visitor Reports Visitor Tracking Visitors Status Visitors Toolbar Button VM Configuration Void Cards 114 2 19 20 102 97 112 103 104 22 120 126 RBH Access Technologies Inc Reader Comments Reader Comments RBH Access Technologies Inc Integra32 User s Guide 155
61. e 27 Chapter 5 Programming General Name user ID and password can be changed entered in the General tab of the Operator Properties Window Operator Properties y x General Database Monitor Language Ed Mame Tester User ID test Password E A Database The access to database can be defined changed in the Database tab Access to each module of the database can be chosen as No Access Read Only or Read amp Write For some items Read Only access may not be relevant If Read Only access is selected for these items their access will actually be Read amp Write Operator Properties x General Database Monitor Language Networks Read and Write Panels Read and Write Access Points Read and write Inputa Read and Write a Head Une Operators Read and Write Schedules Read and Write Holidays Read and Write Cards Read and write Integra32 User s Guide RBH Access Technologies Inc 28 Chapter 5 Programming Monitor Access to commands used in the Device Status Screen and the Alarms Screen can be defined changed in the Monitor tab Check commands that the user is to have access to and uncheck commands that he she is not to have access to Operator Properties x General Database Monitor Language Get version Ae Set datetime pti Get date time bts Ol Full download ef Clear log ee Schedule Inquiry 4 Inputs PGE
62. e multiple sites 3 Enter you company or site name Then click Register RBH Access Technologies Inc Integra32 User s Guide 149 Glossary Glossary Many of the words or terms in this guide have more common definitions than used in industry In this guide we ve used them specifically in the context of security access control For this reason the following glossary of terms defines these terms as used in this guide Access Point A point of entry or exit for an area whose access is controlled and monitored by Integra32 E g a door parking gates Antipassback An Access Control feature designed to prevent improper usage APB of a valid card Ethernet A widely used LAN developed by Xerox Digital and Intel Ethernet networks connect up to 1 024 nodes at 10 megabits per second over twisted pair coax and optical fiber Holiday Any days in which the regular weekly Integra32 time group schedules are not appropriate Statutory holidays and summer shut down periods are two examples In Integra32 Holidays may be assigned special irregular time group schedules that override the regular time group schedule for that day Input Any field apparatus that provides information to an Integra32 system with respect to conditions or status of a monitored component Examples include door contacts thermometers etc Operator Any individual authorized to log on to the Integra32 system for purposes of data entry or monitoring
63. e the default description simply type over it Panel Type The panel type is chosen when the new panel is added and cannot be edited later Enable If the enable check box is not checked then the panel will not be shown in the status screen All Access Point Inputs and Outputs under that panel will also be disabled Disabled items are still in the database but are not considered to be part of the system Inputs The inputs of a Summit panel can be affected by the events from Integra32 access panels They can follow the access panel s inputs by mimicking them going into alarm when the access panel s input goes into alarm Alternatively they can arm disarm the Summit panel when access is granted at a reader the Summit panel s input must be set as an arm disarm input On the other hand they can follow an output on the access panel as if the output was wired to the input Panel Properties 7 x Print Lancel Apply RBH Access Technologies Inc Integra32 User s Guide 93 Chapter 5 Programming Zone There are 32 zones Description The zone name or description can be edited here Panel Designate which panel the input will be affected by Command Choose the function for the input from the pull down list Does it follow an input or an output or is it used to arm or disarm the Summit panel Output If the input follows an output designates which output from the pull down list Risco Group
64. efault description simply type over it Panel Type The panel type is chosen when the new panel is added and cannot be edited later Enable If the enable check box is not checked then the panel will not be shown in the status screen All Access Point Inputs and Outputs under that panel will also be disabled Disabled items are still in the database but are not considered to be part of the system RBH Access Technologies Inc Integra32 User s Guide 99 Chapter 5 Programming Keypads Panel Properties Address This is the address of the keypad in the Risco Group system 7 Name Enter here a description or name of the keypad to be shown in the Integra32 system Emulated Check this box if the Integra32 system will be emulating this keypad and leave it unchecked to monitor an existing keypad Signals from an emulated keypad will be the same as signals from an existing keypad therefore to the Risco Group system there is no difference between an emulated keypad and an existing keypad Integra32 User s Guide RBH Access Technologies Inc 96 Chapter 5 Programming PIN Code Panel Properties 4 Digit Pin Codes Pin Codes Enter the four digits of each PIN code These PIN codes must match PIN codes programmed into the Risco Group system in order for commands from the emulated keypads to affect the Risco Group system Only five of the possible two hundred PIN codes may be entered here Pin Code
65. equested in the Advanced tab of the Access point s properties window Now whenever a valid card is read at the access point the Access Point Activity window will open displaying the cardholder s picture name and card number the date time of the event and at which reader the event happened If PC Decision is not used in the Modes tab then the Access Point Activity window will show all access granted and or access denied events that occur at selected access points Grant Access Grant access will grant access at the reader currently shown in the Reader box of the Access Point Activity window The More button will add a section to the bottom of the window that will display the contents of the cardholder s notes tab Information about the cardholder that needs to be readily available can be display this way The Less button will remove this extension The Hide button will remove the Access Point Activity window from view without turning it off You can also minimize this window The difference between hiding and minimizing is that a hidden window won t show up on the task bar RBH Access Technologies Inc Integra32 User s Guide 119 Chapter 9 Options VM Configuration eMail Configuration To send emails to cardholders announcing their visitors you need to configure the sender s email information on the screen depicted below w isitors Management Configration x User Fields Enter the Email Configuration
66. ess levels that are required should be programmed The only default access level is Master which always provide access to all doors and all floors General Change the Description of the Access Level in the General tab Access Level Access Level Properties x Reader Reader 1 Reader 2 Reader 3 Reader 4 Reader 5 Reader b Reader Y Reader E Integra32 User s Guide 82 Schedule U2 Mon Fri 30arn 5 30 pri U2 Mon Fri 30arn 5 Oper 02 Mon Fri 30am 5 30pm OU Mever O1 Always Oe Mon Fri 4Uam 5 40pm 03 After Hours 04 Mon Fri 8 D0am 5 bpm 04 Mon Fri 8 O0am 5 O pr 04 Mon Fri 8 00am 5 00pm RBH Access Technologies Inc Chapter 5 Programming Program the Schedule corresponding to the Reader e g front door amp rear door in Access Level tab Assign one schedule to each access point Use the Never schedule if no access is be allowed at the access point Any access points added after the creation of the Access Level will be given the schedule Never Access levels can easily be edited anytime after they are created if changes are required Elevator readers require a schedule but the actual schedule selected is irrelevant The actual Cardholder s access is determined by the Schedules on the Floor Groups Access Level Properties i xX General Access Level Elevators Access Level Elevator Elevator Floor Groups Schedule nd 4th th amp 8th F 00 Never 2n
67. est to exit device will report that event if this feature is checked Report Door Not Open The fact that a door was not opened after access was granted at that door can be reported if this feature is checked Report Unknown Format An Unknown Format message indicates that the data received does not correspond to any of the card formats useable by the IRC 2000 This message can be turned off if it is not required Inhibit ID The cardholder name and card number will be blocked for access granted messages if this feature is checked Access granted RTE message will be shown in place of Access granted by card This feature is not applicable for Card PIN schedule RBH Access Technologies Inc Integra32 User s Guide 61 Chapter 5 Programming Unlock Schedule Select a schedule when unlocking and locking of this access point is required Card PIN Schedule Select a schedule when both Card and PIN are required When this schedule is off only a Card is needed for access to be granted Time Outs Timers can be set from 0 127 seconds or minutes Setting a timer to zero will disable it x Unlock ine 5 Sec Extended unlock time 10 H Cor DHO santaj 5 sec DHO alarm SSfsec 7 Timed anti passback Poo Hsec y Repeat Ignore time Poo Hllsec y Unlock Time This is the time the Door Unlock output is turned on for Extended Unlock Time For the Cards given the Extended Unlock Time privilege t
68. file If the panel is offline at the time of the download any files that fail to download will be logged on the Log Screen When the panel comes back on line the download will be executed then again logging the files that are downloaded Commands PC100 Bosch The following commands for panels are available by right clicking the selected PC100 Bosch panel Version The Version queries the selected PC100 for the firmware version it is running The version number will be displayed on the Log Screen Download The Download function allows the operator to manually repopulate the PC100 memory from the database on the server Select any of the listed files to download or select the All Files option to download all files Download messages are posted to the log as files are sent verifying the number of records sent in each file L If the panel is offline at the time of the download the files that failed to download will be logged on the Log Screen When the panel comes back on line the download will be executed then again logging the files that are downloaded Integra32 User s Guide RBH Access Technologies Inc 20 Area and Cardholder Commands Chapter 3 Monitor Screen Clicking either the Areas or the Cardholders button will bring up a selection window From the Areas selection window you can choose the area or areas you wish to view The Cardholders selection window allows you to choose from the list of cardholders The displa
69. five seconds and Input 7 will be disarmed when there is a forced entry at Reader 1 but only during the specified schedule associated with each point Alarms x General Modes Time outs Links Alarms COTY Advanced Access Granted Alarm schedule Access Denied Door Held Open o Always x Instructions Show Video If camera assigned on DWA tab Show Wideo on Event Cancel e First select an event from list on the left The alarm will occur when the message appears in the log screen Then select an Alarm Schedule Causes an alarm when e Then you can select if required an instruction message for the alarm Message creation is described earlier Integra32 User s Guide RBH Access Technologies Inc 64 Chapter 5 Programming M Show Video If camera assigned on DVR tab Check this box to have the DVR show the camera configured on the CCTV tab for this access point on the configured Alarm M Show Video on Events Check this box to have the DVR show the camera configured on the CCTV tab for this access point on the configured message Alarm is not required cctTv L This tab is only available if the CCTV module has been installed The information in this tab is only used to interface with a DVR There are two ways that this interface can be accomplished FT Send ASCII Messages to DWA DVA Name None Camera Information History Information Camera Number o
70. g File to see any errors created by card import Run Import utility Config Import utility View Log File View Log File will call up Mimport log a Notepad file This file will show when the import started and ended as well as any errors that occurred E Mimport log Notepad 10 x File Edit Format Help 31 Aug 009 09 17 Integra Import started 31 Aug 009 9 17 01 AM 31 Aug 009 09 17 Integra Import Completed 31 Aug 009 9 17 02 AM RBH Access Technologies Inc Integra32 User s Guide 143 Chapter 12 Program Groups Chapter 12 Program Groups Integra32 Security System Insure that the Integra32 system is not running before making a selection here in the Program Groups All selections here made will bring up the login window as shown in Chapter 2 on page 4 Administrator P Internet Internet Explorer E mail Outlook Express H Integra32 Service Calls AS 25 Windows Catalog Y Windows Update fam Accessories fan Games Axiom Security fam Startup Internet Explorer Paint y MSN CA Outlook Express i Remote Assistance Windows Media Player Integra32 Data 9 Windows Messenger S Windows Movie Maker lan Axiom Security System 7 PL 2303 USB Serial Driver fin Integras2 Security System Notepad Calculator S a Y 3 E All Programs Start Integra32 User s Guide 144 i My Documents 2 My Recent Documents gt Set Program Acces
71. g as files are sent verifying the number of records sent in each file Card records are sent individually and will indicate the card number and whether it was added or deleted Edited cards are displayed as added If the panel is offline at the time of the download the files that failed to download will be logged on the Log Screen When the panel comes back on line the download will be executed then again logging the files that are downloaded Clear Log The Clear Log option clears the event log of all or selected controllers The database portion of memory is untouched The results will be displayed on the Log Screen Schedule Inquiry This query is used to find out the current state of the time schedules It will list on the Log Screen which schedules are on and which is off RBH Access Technologies Inc Integra32 User s Guide 19 Chapter 3 Monitor Screen Commands PC 100 Summit or Risco Group The following commands for panels are available by right clicking the selected PC100 Summit or Risco Group panel Version The Version queries the selected PC100 for the firmware version it is running The version number will be displayed on the Log Screen Download The Download function allows the operator to manually repopulate the PC100 memory from the database on the server Click on Inputs to download the data Download messages are posted to the log as files are sent verifying the number of records sent for the
72. ght clicking on the label to be renamed There are two numeric fields six text fields and two date fields for the user These fields can be used in searches and can be displayed on badges 5 Integra32 AxiomLite Cardholders x File El z A di i ig New Edit Cancel Delete Search Multi Cards F Print Receipt Last name First name Initials Cardnumber D ough Il onathan r D User Number 1 User Number 2 fo lo User Text 1 User Text 2 User Text 3 User Date 1 User Text 4 User Text 5 User Date 2 7 1604 2009 User Text 6 SK Integra32 User s Guide RBH Access Technologies Inc 96 Chapter 7 Visitor Manager Chapter 7 Visitor Manager To add a visitor into the system the card they are to use must first be entered into the cardholder screen and configured to Type visitor The Profile Photo and More Fields tabs are actually redundant to visitor cards The Cards tab of course 1s required while the Notes tab is optional ps Integra32 AxiomLite Security System Yisitor ioj xj B x MA fF g L Ba 4 Add Edit Save Delete Cancel Search CheckIn Check Out Receipt Track E mail Lastname Firstname NationallD Card Humber jo Personal Information Reason to Visit Address Date of Birth City fF Phone state ES County Employer Postal Code Time allotted jo Hours Notes visiting Lastname 2 Firstname Nc Employee Card fo Last Ghecked In Last
73. he Door Unlock output will turn on for this length of time instead of the regular Unlock Time DHO Warning If a door is still open when the Lock Time expires the Door Held Open Warning timer will start When the Door Held Open Warning time expires the Access Point will go into Door Held Open Warning posting DHO Warning message and pulsing the reader s buzzer Integra32 User s Guide RBH Access Technologies Inc 62 Chapter 5 Programming DHO Alarm If a door is still open when the Door Held Open Warning time expires the Door Held Open Alarm timer will start When the Door Held Open Alarm time expires the Access Point will go into Door Held Open Alarm posting DHO Alarm message and turning on the reader s buzzer continuously Since the DHO Alarm timer starts when the DHO Warning timer expires if the DHO Warning time is set to zero then the DHO Alarm timer won t be started Timed Antipassback Set the amount of time for Timed Antipassback here Timed Antipassback will reset at the end of the programmed time allowing the cardholder to be granted access into an area they are already logged into If a cardholder tries to re enter an area before the timer expires they will cause an antipassback violation Repeat Ignore Time Set the amount of time after a card is read until that card can be use again at that door After the card is read that card will be ignored for the set amount of time Other cards can be used and each wil
74. he user be familiar with the DS7400X1 panel and has the ability to program PIN codes and parameters into the panel The PC100 interface has been designed to connect the Integra32 network to the DS7400X1 alarm panel through the option or keypad bus It will emulate a keypad when a link has been provided and report status to the Integra network when included in the list of keypads In order for the alarm panel to poll the emulated keypad the keypad assignment for the alarm panel should be programmed Keypad addresses 1 10 connect to the keypad bus and addresses 11 15 is connected to the option bus The PC100 can monitor all keypads on the bus that are listed under panel properties Keypads A Link to an Event will use an emulated keypad to enter a password followed by a command If the password is not programmed into the alarm panel no operation will take place Whenever a command is executed the green Health LED will turn on The green Health LED will turn off when the alarm panel finishes its poll to the keypad General Panel Properties x General Keypads PIN Code Links Address Description Je PE OO 32 Panel type PC100 Bosch coo Ao Integra32 User s Guide RBH Access Technologies Inc 48 Chapter 5 Programming Address The address is selected at the time creation and cannot be edited later Description To change the default description simply type over it Panel Type The
75. her RS232 or a USB 485 module Network Properties x General Comms Advanced Fort Type Direct Network Foll Retries g Network Time Out fi 000 Milli Secs recommended minimun 500 Properties Comm Port com Baud 36000 z Integra32 User s Guide RBH Access Technologies Inc 36 Chapter 5 Programming Modem Connect The controller network JRC 2000 is located remotely and is connected to the PC via dial up modems Network Properties 7 X General Comms Advanced Port Type Modern Network id Poll Retries g Network Time Out fi 000 Milli Secs recommended minimun 500 PC Modem Moder E 1 Sportster Yi 33 6 FAX 9600 Phone Schedule Hang up atter 5 a Mini Panel Modem Phone Password Init String EOF SO 1V 0807 amp D 08H ORF 1 amp 5 7 HO Select a modem and configure it in the Control Panel to a maximum baud rate equal to that set at the panel e g 9600 Enter the phone number for the network to be called by the PC and the call back phone number for the panel to call Auto hang up time can be set in minutes the number of minutes with no activity Integra32 User s Guide 37 RBH Access Technologies Inc Chapter 5 Programming The call back criteria are set under the Dial out tab of each panel Which events will cause the panel to call up the PC can only be set in the panels of a modem network x Schedule Access Gr
76. hours or minutes or everyday at x Cardhlumber Y ler E Everyday at 12 00 00 AM RBH Access Technologies Inc Integra32 User s Guide 139 Chapter 11 Tools Check the appropriate box to have the import utility start automatically with the Operating System To have all actions taken by the import utility logged check the second box INEN Integra32 User s Guide RBH Access Technologies Inc 140 Chapter 11 Tools Note the icon E in the windows systray indicating that the utility is active Import Wizard Click Finish to complete the setup The utility can them run on a schedule or opened to be run manually RBH Access Technologies Inc Integra32 User s Guide 141 Chapter 11 Tools Run Import Utility Run Import Utility will run the utility immediately Card Import Utility Integra32 Card Import Utility Click to Run the configured Card import now Run Import utility 44 Config Import utility View Log File The status bar will display the progress and indicate when the import is complete oix Integra32 Card Import Utility Click to Run the configured Card import now pb Run Import utility 44 Config Import utility View Log File Import Completed Integra32 User s Guide RBH Access Technologies Inc 142 Chapter 11 Tools View Log File Card Import Utility Integra32 Card Import Utility Click to see the lo
77. ht to revise this publication and to make changes to the content hereof from time to time without the obligation of RBH Access Technologies Inc to notify any person or organization of such revision or changes RBH ACCESS TECHNOLOGIES INC 2 Automatic Road Suite 108 Brampton Ontario CANADA L6S 6K8 Printing Date May 25 2010 Integra32 Revision 4 2 Intega32 User s Guide RBH Access Technologies Inc Table of Contents Table of Contents INTRODUCING INTEGRA V a lis 2 INTEGRA32 SERVER CLIENT NETWORK SETUP ui 2 GETTING TO KNOW INTEGRAS ario 3 COMMAND AIR acs ss NA 3 MPSS tao IA E A E EAE ET 4 EA AAA In A E A A A EE S DATABASE SCRE Bl anne aioe ee on Oe RPP oa 9 DENICESTATUS SERE Nar n 10 ALARM o CREEN aos 10 EVENTLOS IEREEN a aa GS Ou o Roe Seda 11 COMMAND SCREEN a aa 12 A A IN OS 12 HOWTO RE XECUTE A COMMAN Dato das 13 COMMAND aia 13 ES lO COMMANDS seeren a L E e E AN E Ne ta E A A 14 COTS 2 a a A a E e cere ees 14 INPUT OTN TS C OMMAN DS nia a a 16 Coa aan 16 OUTPUT PONTS COMMAND S 2 ai SAA ee NA 17 OTTO ate Sea NESE E N E AE EAE E I E EAE I te aan 17 PARERS E OMMAN DS sd A AA E A 18 Commands IRE2000 URCZ00U 0 sad 19 Commands P C100 Summit or Risco OTURA A A AAA 20 Commands PCIOOBOS CA A id 20 AREA AND CARDHOLDER COMMANDS cscccsecccecccscccececucccusccececucseusceecsuucseueseeseeuceeuesuueseeuceeussueseeeceensseseseseseuness 21 COMMONS 22300 ASAS E Saat eb eae ath ssi AA beep te tu At ate SoS ead a
78. ime These times set playback start time how much time before the event time and the playback end time how long to continue the playback after the event time This configuration is used by the History Reports DVR tab to playback video associated with a logged event L The Links tab is only available for programming for general purpose outputs RBH Access Technologies Inc Integra32 User s Guide 17 Chapter 5 Programming Links utp tt Select an event Output Off Command Device Duration Schedule a 3 y E Lancel e First select an event Either Output On or Output Off e Then select up to eight commands to be executed with that event The command selection list includes arming or disarming an input turning on or off an output locking or unlocking an access point setting High Security mode on or off for an access point and turning Disable Forced Entry on or off e After you have selected a command an appropriate device needs to be selected input output or access point e Choose the duration of the command 0 127 seconds or 0 126 minutes Not all commands can be timed High Security on and off and Disable Forced Entry on and off cannot be timed A schedule can also be selected for each command the command will only be executed when the schedule is on Integra32 User s Guide RBH Access Technologies Inc 78 Chapter 5 Programming Elevators aa Panel 1 a
79. is produced For some reports there is a main report and sub report If you select Show Subreport which is selected by default the ZD field cannot be unselected It is required to link the main and sub report The fields selected in this list are for the main report only Up to ten fields can be selected If you select more than ten fields the first ten will be shown e Click the Next button to select the sort order for the report Use the Move All Forward and Back arrows to select sort fields Then choose Ascending or Descending for that field Click the Next button to go to next screen e Click on Preview Report to see the report or click on Begin Again to view a new report or click on Finish to end The user can follow similar steps to preview or print other kinds of Database Reports as well RBH Access Technologies Inc Integra32 User s Guide 111 Chapter 8 Reports Visitor Reports Select Visitor Reports from the Reports menu to launch the following window where the user has the option of selecting from many available visitor report formats x a A E Preview Print Font DVR 5 48 visitor Report Date Criteria fe visitors Log fl visitors activity Eom 24 Apr 2010 12 00 00 AM fe visitors Currently Checked In fe Visitors Report By Department S visitors Report By Employer To 24 Apr 070 11 59 59 PM F visitors Report By Employee fe visitors Report By Reason Fe visitors Report By Cardnu
80. ith the camera you selected as you could be using more than one DVR this configuration is used by the History Reports DVR tab to playback video associated with a logged event This selection is only available if the optional license for the DVR Software has been purchased and installed RBH Access Technologies Inc Integra32 User s Guide 1 Chapter 5 Programming AAA o ales Alarms Send ASCII Messages to DWA DWR Name Mone Camera Information History Information Camera Humber D FTZ Camera Fre Event Time Fost Event Time The second way the interface can be used is to associate with a specific DVR DVR are set up in the Database Screen under DVR First select a DVR for the pull down list under DVR Name Next configure the Camera Information Select a camera number indicate whether it s a PTZ camera or not and if it is enter a preset number if applicable Then set the History Information Set the Pre Event Time and the Post Event Time These times set playback start time how much time before the event time and the playback end time how long to continue the playback after the event time This configuration is used by the History Reports DVR tab to playback video associated with a logged event L Links and Alarms tabs are available only for general purpose inputs Integra32 User s Guide RBH Access Technologies Inc 72 Chapter 5 Programmi
81. itor Reports History Reports Ctrl H Reports are explained later in Chapter 7 Database Reports Reports are explained later in Chapter 7 This selection is only available if the optional license for the Visitor Management System has been purchased and installed Integra32 User s Guide RBH Access Technologies Inc 6 Chapter 2 Getting to know Integra32 Help File Options Links Tools Reports Help Contents ce About Use this menu option to display information regarding your Integra32 software version the licensing of the software as well as dealer information x 5 About Integra32 AxiomLite Security System Integrase AxiomLite Security System version 3 6 6 R 4 2 Copyright 1995 2010 RBH Access Technologies Inc Canada Company RBH Access Technologies Inc email info mrbh access com WIAA rDh access com This Product is licensed ko Finger Print Enrollment Dealer Information RBH Access Technologies Inc 2 Automatic Road Suite 108 Erampton Ontario L65 666 Create a text file in the site folder e g default named rbh ini as shown below to display dealer information in the About screen Up to nine lines of information Dealerlnfo can be included i rbh ini Notepad O x File Edit Format Help Dealer Replace RBH Access Technologies Inc with your company name Dealerhame RBH Access Technologies Inc Dealerlntol 905 90 1515
82. l be subject to the ignore time individually Links x select an event Forced Entry Command Device Duration Schedule ee eee g U B ee eee B D O O B T O O SS u gp oC alar te A O o g a B 4 E q F Cancel e First select an event The selectable events are Access Granted Access Denied Door Locked Door unlocked Door Held Open Door Not Open Forced Entry Restore High Security On High Security Off 3 Links and 5 Links 3 Links and 5 Links indicate either three or five consecutive Access Granteds to execute the link and Access Granted RTE RBH Access Technologies Inc Integra32 User s Guide 63 Chapter 5 Programming e Then select up to eight commands to be executed with that event The command selection list includes arming or disarming an input turning on or off an output locking or unlocking an access point setting High Security mode on or off for an access point and turning Disable Forced Entry on or off e After you have selected a command an appropriate device needs to be selected input output or access point e Choose the duration of the command 0 127 seconds or 0 126 minutes Not all commands can be timed High Security on and off and Disable Forced Entry on and off cannot be timed e A schedule can also be selected for each command the command will only be executed when the schedule is on The example above has the Output 3 being turned on for
83. lected Void will immediately deactivate all selected cards Select All will put a check mark in the select field for all of the listed cards Integra32 User s Guide RBH Access Technologies Inc 126 Chapter 11 Tools Finger Print ioixi je Add Ep edit Delete E Configure 1 FRBHBIO 002 Finger Print Reader Finger Print opens a screen from which to manage the RBHBIO 002 and their finger print data 2 This selection is only available if the optional license for the Finger Print Reader has been purchased and installed RBH Access Technologies Inc Integra32 User s Guide 127 Chapter 11 Tools Reader Configuration ox File Device Connect A Read Settings Se Write Settings Get Time E Set Time 4 Get Local Time Device Address Time fi _ Apr 39 E 2010 Apr 16 13 38 27 Device Info f Serial f TCP IP IP Address fi 20 100 75 172 Fort 4370 Integra32 User s Guide RBH Access Technologies Inc 128 Chapter 11 Tools Finger Print Reader Query Finger Print Reader Query Finger Print Reader d ES Disconnect User Existance of Finger Prints Delete User Total of users Device D IP Address Port fi fi 25 100 75 172 4370 Query Response Device 1 Connected Use this selection to query RBHBIO 002 readers This selection is only available if the optional license for the Finger Print Reader has been purchased and installed RBH Access
84. lication Integra32 s 32 bit software architecture together with a Microsoft Windows operating system ensures that security management needs are met easily and economically with a minimal amount of training The IRC 2000 Intelligent Field Panels utilize flash firmware for easy upgrades This panel uses fully distributed intelligence for off line operations In addition to supporting two card readers each IRC 2000 Intelligent Field Panel also has eight fully supervised alarm inputs along with eight outputs The IRC2000 s memory has been increased to now hold 5 000 card and can be further extended to hold 8 000 cards An alternate panel the URC2000 can be used along with or instead of the original IRC2000 This panel also uses fully distributed intelligence for off line operations In addition to supporting two card readers each URC 2000 panel has four fully supervised alarm inputs and four outputs as well as a 3 000 card acpacity Communication is handle through an RS485 port Integra32 Server Client Network Setup Please see technical document TB63 for a step by step guide to installing Integra32 NIZ In order for a remote client to connect to the server the server must first be running This should not be a problem since the Integra32 server now runs as a service and should be running at all times Integra32 User s Guide RBH Access Technologies Inc 2 Chapter 2 Getting to know Integra32 Chapter 2 Getting to Know I
85. m each panel in the network This prevents log messages from being lost It takes about 5 seconds for the PC100 to time out and take over the network When the PC100 has control of the network it will request time and date and keep updating the latest time every 32 polls When the host comes back on lines all log messages are ignored that are time stamped with a date and time earlier than last recorded This prevents old messages from triggering false alarms while allowing the host to update its log file All log messages are passed through the event filter transforming all 128 different log messages into a few events All activity is synchronized to the Summit LSCP bus If the bus is disconnected all activity on the PC100 will halt The PC100 acts like a zone expander to the Summit panel allowing up to 32 zones Each zone is mapped to an element in the IRC network The state of each element in the IRC network will cause a zone to appear open or closed The PC100 acts like an IRC panel at address 32 to the host The host can poll the PC100 to see if it is online request status write to memory and update flash memory General Panel Properties x General Inputs Address Description J2 PE OO 32 Fanel type PC100 Summit coo Asc Integra32 User s Guide RBH Access Technologies Inc 52 Chapter 5 Programming Address The address is selected at the time creation and cannot be edited later Description To chang
86. mber Fal visitors Report By Visitor fe visitors Report By Reader Choose a report format and select the Start and End Date and Time for the time period you want to preview the report for 2 This selection is only available if the optional license for the Visitor Management System has been purchased and installed Integra32 User s Guide RBH Access Technologies Inc 112 Chapter 9 Options Chapter 9 Options System Options General e Options x Sustem options im Number of days to keep Event History E 365 d Yod cards after jo ER DA IMC LABEL User options oy Keyboard timout min T rir lv Alarm sounds M Print Area Report on Input Alarm on All Printers Activate Card When Visitor Checks in Group Cards System Options Number of days to keep Event History The System Options window allows the user to customize number of days to keep Event History and Keyboard time out in minutes The default number of days to keep Event History is 365 days Each history file keeps the history information of one calendar day If 365 days of history is being kept then only 365 files will be kept When a new history file is created the oldest file will be deleted so that only 365 files are maintained RBH Access Technologies Inc Integra32 User s Guide 113 Chapter 9 Options Auto void cards after At 1 00 am cards that have not been used within the specified number
87. me Firstname NationallD Card Humber jo General More Fields Assets Track Photo Photo Picture Files _ E Signature I J ofo gt bl The Photo tab shows all the templates from the badging template module Only the fields valid for the visitor management will be shown on the badging templates in this module Integra32 User s Guide RBH Access Technologies Inc 104 Chapter 8 Reports Chapter 8 Reports The Integra32 report creation facilities allow you to customize an almost unlimited number of reports and can be used as an extremely valuable management tool From Reports menu you can choose to launch History Report or Database Report Window History Reports Select History Reports from the Reports menu to launch the following window where the user has the option of selecting from many history reports available History Report File Reports Help E th aH Reports y Preview DVR Date Time 1200 a eee Start 1 May 2006 12 00 00 AM T apep End 31 May 2006 y msasarm Click Preview Print to output a report for all selected events and messages for start to end datetime RBH Access Technologies Inc Integra32 User s Guide 105 Chapter 8 Reports File Print From the file menu the user can Print Select History Path or Exit from the History Report window The Print command will produce a printed report showing the data selected for the chose
88. med from 6 00 p m to 8 00 a m by the scheduler and a permanent command is issued to arm the door the door will remain armed forever and will not be disarmed by the scheduler A permanent command remains in effect until cleared by a second operator command or fresh files are downloaded to the controller Semi Permanent Semi permanent commands are executed like permanent commands but do not override operation of the scheduler In the above example of the door armed by scheduler between 6 00 p m and 8 00 a m if a semi permanent command is issued at 4 00 p m to arm the door the command is executed The scheduled operation remains unaffected and on the next day at 8 00 a m the door will disarm and revert to the normal arming schedule Timed Timed commands allow an action to be performed for a specified duration For example turn on an output for five minutes The time can be specified from 1 to 127 seconds or minutes RBH Access Technologies Inc Integra32 User s Guide 13 Chapter 3 Monitor Screen Access Points Commands Clicking the Access Points button on the Command Toolbar depicts the status of Access points on the Device Status Screen a D i gt zi ME E EE Semppermanent ACCESS Inputs Outputs Panels Areas Cardholders La A feader Locked Nomal in T Reader 3 wW Grant access ocked Normal E MM Reader 4 Lock Door ocked Mormal Q F Reader 5 a Unlock Door ocked Hormel lA Re
89. metric Readers to your COM port check the box This selection is only available if the optional license for the Badging Software has been purchased and installed RBH Access Technologies Inc Integra32 User s Guide 115 Chapter 9 Options Magnetic Encoder Setup Clicking in the Magnetic Encoder Setup button under the Badge tab of System Options window will launch the following window to setup properties for magnetic encoding Magnetic Encoding Setup x Printer Model None Track 1 Track 2 Track 3 Field Mame Hone Field Length A Cancel Select the printer model in this window The fields to encode can be selected for each track once the printer model is selected Note gt The field length is fixed and cannot be changed gt If None is selected for the printer model the track fields for encoding will not be available gt The printer properties for encoding should be setup for the printer from the control panel Integra32 User s Guide RBH Access Technologies Inc 116 Chapter 9 Options Font You can change the default font for the main client screen by browsing the font list select a font and click OK The default font is MS San Serif 5 Options RBH Access Technologies Inc Integra32 User s Guide 117 Chapter 9 Options System Messages e System Messages l x Message Access Point Mode Changed Input Output Audit message Cardholder Access Reques
90. n and search for the appropriate cardholder Department and Employee Card will be filled in by the system Last Check In is also filled in by the system Integra32 User s Guide RBH Access Technologies Inc 100 Chapter 7 Visitor Manager User Fields Integra32 AxiomLite Security System Visitor oj x lal A z Ph a a E 8 Add Edit Save Delete Cancel Search CheckIn Check Out Receipt Track E mail Lastname Firstname MationallD Card Humber jo More Fields User Text 1 User Number 1 User Text 2 User Number 2 User Text 3 User Text 4 User Date 1 User Text 5 visiting Lastname 2 Firstname Pepauient Emplovee Card fo Last Ghecked In Last Visited Checked In Checked Out I J ofo b bl User Fields are customized fields to hold data pertaining to your visitors The headings for these fields are set in VM Configuration under the User Fields tab RBH Access Technologies Inc Integra32 User s Guide 101 Chapter 7 Visitor Manager Assets E Integra32 AxiomLite Security System Yisitor o est xj E wx o gt A LU B 53 Add Edit Save Delete Cancel Search CheckIn Check Out Receipt Track E mail Lastname Firstname MationallD Card Humber jo Track Photo visiting Lastname 2 Firstname pebauitent E mployee Lard fo Last Ghecked In Last Visited Checked In Checked Out I J ofo b bl Under the Assets tab in edit mode
91. n report Select History Path Reports Preview If your history files are not being saved to the Integra32 folder then the path to their location will be required The user can select the kind of report they want to preview or print from the Reports menu The options available are Main Card Holders Access Points Inputs Outputs Controllers Alarms Operators Time amp Attendance and Card Holder Simple The same options are available from the Reports button of the toolbar The user sets the Start Date End Date Start Time and End Time for any report they have selected to preview or print The report will span from the start time of the start date to the end time of the end date unless the daily report box is checked If the daily report box is checked then the report will still span from the start date to the end date but only include the times between the start time and end time of each day Clicking the Preview button of the toolbar the user can preview or print any of the selected reports for selected time period To understand the History Reports Window in detail let s take the example of one of the selected options Cardholders From Reports menu or Reports button select Cardholders to show the following screen Integra32 User s Guide RBH Access Technologies Inc 106 Chapter 8 Reports e History Report Card Holder x File Reports Help E Le Reports Preview Date Time fizo ee ee St
92. n the server that holds the source data Click OK w Build Connection String Provider SQLOLEDE server SERVER Trusted Connection User Id sa Password password Database DataSource d x OK Cancel You can verify the connection with Test Connection Select the table or query of the database set above and then provide the path to the target folder by either typing or browsing Import Wizard Connection String provider SQLOLEDE iserver TESTINGSERYER database Test Connection Mew Table Query Card_Import le Integra Folder c Program Files rbhiIntegras2 Default RBH Access Technologies Inc Integra32 User s Guide 137 Chapter 11 Tools Then select the appropriate destination fields for the corresponding source fields e g select Surname for lastname Firstname for firstname and AccessLevel for falid depending on the data provided by the table or query Import Wizard List Source Field Text File Destination Field 4xUserLT mdb cardnumber Cardhumber lastname Surname Firstname Firstname Falid AccessLewel expirydate ExpiryDate bal Text5 Texte Cardhumber re Status FIN Help Cancel Back Mext gt Finish Click Next to continue Integra32 User s Guide RBH Access Technologies Inc 138 Chapter 11 Tools Complete the configuration Select a unique key field If required check Schedule Import and select either every x
93. nd Date 12 26 2010 10 00 00 PM a Integra32 User s Guide RBH Access Technologies Inc 30 Chapter 5 Programming Schedules Before cardholders are entered any additional Time Groups that are required should be programmed Up to thirty two schedules can be programmed for Integra32 system gt o am os CO M9 Add Schedule O A 2 Refresh le o D Schedules 3 Mx Delete 0 After Hours D after FE GER z E Mon Fri 8 00am 5 00pm Ey Mon Fri General Change the Description of the Schedule under the General tab of the Schedule Properties Window Time Zones Program the Time Zones for the New Schedule in the Time Zones tab of the Schedule Properties Window Schedule Properties x General Time Zones Start Sun pr J m J 7 Al Period 1 0000 oro Pernod oe Loe oo Meee Y Y AAA fo e w e e Period 6 OD00 0000 Cancel RBH Access Technologies Inc Integra32 User s Guide 31 Chapter 5 Programming e Fight time periods can be programmed Click to check or uncheck a day for the period End time must be later than start time Valid times are from 00 00 to 24 00 even though 24 00 is never actually reached it represents the end of the day Schedules that cross midnight will require two periods One to go up to 24 00 on the first day and a second to start at 00 00 of the next day After you create a new schedule edit an existing
94. ng Links Select an event Input Alarm bd Command Device Duration Schedule 1 Output On Output 3 0WWsec 7 02 tter Hours y 2 Disable forced entry On Y Reade A 7 f0 amays y Alarms Cancel e First select an event Selectable events are Input Abnormal Input alarm Input Normal Input Restore and Input Trouble e Then select up to eight commands to be executed with that event The command selection list includes arming or disarming an input turning on or off an output locking or unlocking an access point setting High Security mode on or off for an access point and turning Disable Forced Entry on or off e After you have selected a command an appropriate device needs to be selected input output or access point e Choose the duration of the command 0 127 seconds or 0 126 minutes Not all commands can be timed High Security on and off and Disable Forced Entry on and off cannot be timed e A schedule can also be selected for each command the command will only be executed when the schedule is on RBH Access Technologies Inc Integra32 User s Guide 73 Chapter 5 Programming Alarms General Detaile CCTY Links Alarms Input Abnormal Alarm schedule Input Normal foo Hever Input Restore Input Trouble Show Video lf camera assigned on DWA tab Show Video on Event e First select an event from the list on the left The alarm will
95. ntegra32 User s Guide RBH Access Technologies Inc 60 Chapter 5 Programming First Person Delay Access points with lock unlock schedules will lock and unlock according to the schedule If First Person Delay is selected the door will remain locked until the first card is granted access after the start of the schedule RTE Bypass DC This feature is used with the doors having mechanical egress The Request to Exit device will bypass the door contact but will not unlock the door The door can be opened without causing an alarm since the contact is bypassed PC Decision Required Selecting PC Decision Required takes the decision to grant access away from the panel If the panel would normally grant access it wouldn t Instead it simply sends a message to the PC Access Requested An operator at the PC can then decide to grant access or not Other software functions can also use this feature e g global Antipassback 24 This feature doesn t work in conjunction with Deduct Usage PC Decision Required will override Deduct Usage High Security Only cards with High Security privilege will be granted access at access points in High Security mode Facility Code Mode Access points in Facility Code Mode will grant access based upon the card s facility code and not on the card s card number Cards not entered into the system that have the correct facility code will be granted access Report RTE Access granted by a requ
96. ntegra32_ Integra32 lets you manage and monitor all your security access needs using a standard PC There are four separate parts to the Integra32 s main screen Integra32 AxiomLite Security System Ioj x File Options Links Tools Reporte Help Log Out Shabus Alarm AP Activity Cards Wisihors DF Help Configure tal ae o HE 23 o Reader Input Outputs Panels Areas a El Integra System E E Users 2 2 tbh Holidays Fl Schedules eel Mever al E T Jm T i S a Log message Messages 2 010 A4pr 15 13 38 11 System Downloaded file Command sched Networks 010 4pr 15 13 38 12 System Downloaded file Links Panel 2 2010 4pr 15 13 38 13 System Full download ended Panel 2 E Network 1 lf Panels Fl A Access Levels ng Master 010 4pr 15 13 38 17 Audit message Record deleted Schedule Event log El tbh Site Default 201 0 4pr 15 1335 4 Command Bar Menus and buttons to access other features of the system are available on the Command Bar Integra32 has the following menu options File Options Links Tools Reporte Help Each of these items has a drop down menu with further options that launch the functions contained in the drop down menu e g Log Out of the Integra32 system In addition Integra32 provides Toolbar buttons as an optional means of launching either the same function contained in drop down menu or to launch new windows
97. oe Panic Alarm T Panic Alarm Messages Instruction that operators need to follow under certain circumstances can be created and saved here x General Message Description E Low Temperature General Under the General tab of the Message Properties Window message descriptions can be edited Message The message is entered under the Message tab Integra32 User s Guide RBH Access Technologies Inc 34 Networks General Chapter 5 Programming Up to sixteen networks can be connected on the Integra32 system The description of each Network can be changed in the Description box under the General tab of the Network Properties Window for each network Under the Comms tab properties of the port are configured Choose one of the four options available for Port Type works E a Net Network 3 Under the General tab of the Networks Properties Window network descriptions can be edited Network Properties Y NO gt e TU Network 1 RBH Access Technologies Inc Integra32 User s Guide 35 Chapter 5 Programming Comms Poll Retries Poll Retries is the number of times the Integra Server will poll a panel before declaring the panel offline and moving on to poll the next panel Network Time Out Network Time Out is the amount of time the Integra Server will wait for a response before polling again Direct Connect The controller network JRC 2000 is connected directly to the PC serial port via eit
98. of days will be automatically deactivated No cards will be deactivated if the number of days is set to zero DVR The DVR box allows the choose one of the two options available for video display IMC HISTORY or IMC LABEL IMC LABEL displays the camera label on the played back history from the DVR User Options If a user has entered a keyboard time out Integra32 will automatically log out if there is no mouse or keyboard activity for the duration of keyboard time out period Va To prevent auto log out click and uncheck the keyboard time out option Alarm sounds Click in the check box to turn on the alarm sounds which are heard through the computer speaker Click again in the check box to turn it off Print Area Report on Input Alarm on All Printers Click in the check box to turn on the feature click again in the check box to turn it off With this box checked all prints listed on the server will print an area report when the input goes into alarm If the box is not checked the report is printed only on the default printer of the server An input must be selected in the area properties before any report can be printed Activate Card When Visitor Checks In With this box checked a visitor s card will be activated when the visitor is checked in and deactivated when the visitor is checked out Group Cards This selection tells the system that cards under a single cardholder are to be grouped so that if one
99. of these cards is used to enter an area all of the cards in the group will not be allowed to be used to go into the same area Any one of the cards may be used to go into another area For this feature to work PC Decision Required and Hard Antipassback must be on 2 This selection is only available if the optional license for the DVR Software has been purchased and installed Integra32 User s Guide RBH Access Technologies Inc 114 Chapter 9 Options Badge General Badge Font Ficture device type C General ir IP Picture device Petes eee ooo Signature device Device 1 Fingerprint device None Save File 4s J PG E Printer Hame Dell Laser Printer 1170 Duplex Badge Printing Use Dazzle30 settings for photo capture Biometric reader connected to local comport Magnetic Encoder Setup Use this tab to define properties of the Badging utilities Designate where the cardholder s image signature and fingerprint will be acquired For devices to be listed here they must first be installed in the operating system according to the requirements of Badges They must also be Twain devices IP cameras can be selected as well Designate as well the format to save the image as and what printer to use for printing badges M Also click in the check box for double sided printing of badges M Check Use Dazzle 90 if you are using a Dazzle 90 for photo capture M If you are connecting Bio
100. oints Report Areas Report Card Holders by Department Cardholder Reader Report Cardholders Report Elevator Elevator Floor Groups Global Links Report Holidays Report Input Points Report Network Controllers Report Operators Report Output Points Report Reader Cardholder Report Time Groups Report Cancel 4 Back Hest gt Elmnteh Options The options available for Database Report are Access Levels Report Access Points Report Areas Report Card Holders by Department Cardholder Reader Report Cardholders Report Elevator Elevator Floor Group Global Links Report Holidays Report Input Points Report Network Controllers Report Operators Report Output Points Report Reader Cardholder Report Time groups Report Integra32 User s Guide RBH Access Technologies Inc 110 Chapter 8 Reports e Select one of the reports available e g Access Points Report Click the Next button to select the options available in for the chosen report e Select the items to include in the report or click in the check box for Select All if you want to include all the items available in your report e Click the Next button to select from the available fields to include in the report or check the Select All box to include all fields By default four fields are selected If up to five fields are selected a simple report will be produced For more than five fields a detailed report
101. onds Door Held Open warning will be fixed at twenty seconds and Door Held Open alarm will be fixed at thirty seconds Address Description A Panel 5 Panel type UBRC2000 with ELC MW Enabled Cancel Outputs Up to four eight output relay boards may be used with each URC2000 Elevator Control These outputs may be split between the two readers of the panel or all outputs may be used with just one reader Use the scroll buttons to select the number of relay boards that are connected Integra32 User s Guide RBH Access Technologies Inc 46 Chapter 5 Programming Pam AAA Number of ELC boards Wm Floor description o OA Output 24 Output 25 Output E Output 27 Output 8 Output 3 Output 30 Output 31 Output 32 Rename the outputs for your convenience AAA General Reader Options Site codes Alarms Code Reader Links Outputs Number of ELC boards a Floor description 2 Cab A 12th Floor Cab A 13th Floor Cab A 14th Floor j Cab A 15th Floor Cab A 16th Floor Cab A 17th Floor Cab B 2nd Floor Cab B 3rd Floor Cab E 4th Floor 20 Cab B 5th Floor hd Cancel RBH Access Technologies Inc Integra32 User s Guide 47 Chapter 5 Programming PC100 IRC2000 panels connected along with the PC100 must be running firmware version 76 or higher for the PC100 and the IRC2000 panels to function together correctly Bosch It is recommended that t
102. option From the Backup Configuration Screen the destination folder into which the backup files will be saved is selected The default destination setting is Mntegra32 Default Backup Checking Data Files will backup the data files particularly AxlogxLT mdb AxsystLT mdb amp AxuserLT mdb While checking History Files will backup all of the currently held history files Cardholder Image Files when checked will backup the cardholder pictures The Log Screen will display these files as they are backed up RBH Access Technologies Inc Integra32 User s Guide 123 Chapter 11 Tools Integra32 AxiomLite Backup Configuration Wizard x Select destination tolder Ic Program Files rbh sl ntegra 32 0 efaultyB ackup s El Select the file s to backup Data Files History File Wf ardholder Image Files Cancel Back Het gt Finish Configure Auto Backup The auto backup can be configured to happen at a specified time on specified days of the week For example the backup can be performed at 11 30 a m every Monday or at 10 15 p m every Tuesday and Thursday These backed up files are saved by date the file is designed bkpY Y Y YMMDD where YYYYMMDD is the backup date and you can set how long they are to be kept If for example you set the backup for every Monday and Friday to be kept for 31 days Backups older than 31 days will be over written Integra32 AxiomLite Backup Configuration Wizard X
103. ow option will be discussed in Chapter 8 Visitor Management configuration is accessed by selecting VM Configuration Links File Options Links Tools Reporte Help ad Global Links This is where Global Links are setup details of this are shown in Chapter 9 Tools Fil Options Links Tools Reports Help E Backup Es Yoid Cards Finger Print i Query Finger Print Reader 3 Badge Template Designer Card Custom Fields E Card Import The Tools menu gives the options for Backup Void Cards Finger Print Query Finger Print Reader Badge Template Designer Card Custom Fields and Card Import which are covered in more detail in Chapter 10 This selection is only available if the optional license for the Visitor Management System has been purchased and installed This selection is only available if the optional license for the Finger Print Reader has been purchased and installed This selection is only available if the optional license for the Badging Software has been purchased and installed This selection is only available if the optional license for the Card Import Utility has been purchased and installed RBH Access Technologies Inc Integra32 User s Guide 9 Chapter 2 Getting to know Integra32 Reports File Options Links Tools Reports Help E History Report mA Database Reports E Visitors Reports Use this menu option to customize and generate History Reports Database Reports and Vis
104. r side A or B on which code reader link has to be executed Then as with local links you choose which event on what device will cause the link to be executed You can choose up to four things to have happen with one code Dial Out This tab is visible only if the Network to which the panel is connected is Modem Network For more information see page 38 RBH Access Technologies Inc Integra32 User s Guide 45 Chapter 5 Programming URC2000 with ELV The first five tabs General Reader Options Site Codes Alarms amp Code Reader Links are almost the same as above for the regular URC 2000 URC 2000 Elevator panels have a sixth tab Outputs These outputs on the ELC 08 boards are the only outputs that can be used for elevator control Reader ports on an elevator board can be used for either elevator control or access control When an access point is used for elevator control change all of its default inputs and outputs to general purpose the elevator reader won t need them If you use the access point for access control it won t have all of the features that access points on other panels have Access points on an elevator control will not have Deduct Usage Disable Forced Entry Unlock Schedule First Person Delay RTE Bypass DC Report RTE Antipassback or an Alarm Shunt output Timed commands will act as semi permanent commands Extended Unlock time will be fixed at thirty sec
105. r unit Device name Use the RBHBIO 002 reader software to enroll register finger print data 2 This selection is only available if the optional license for the Finger Print Reader has been purchased and installed Integra32 User s Guide RBH Access Technologies Inc 08 Chapter 6 Cardholders Receipt Receipt will create a printable document for the cardholder to sign indicating that the cardholder has taken possession of the card Receipt 1604 2009 303 42BM Card Name Card Number Department User Number 1 User Number 2 User Text 1 User Text 2 Access Level I have received the above card and accept that I have to report it immediately if it is lost The card is personal and never to be handed to anybody else Signatura Card Name Jon Date 1604 2009 RBH Access Technologies Inc Integra32 User s Guide 09 Chapter 6 Cardholders Cardholders Tabs Cards 4 Since cardholders can have multiple cards card features will only be shown for selected highlighted card number only When adding or editing cards ensure that the proper card number is selected highlighted i Integra32 AxiomLite Cardholders x File E fl KD A rh Ta i Mew Save Cancel Delete Search Mult Cards F Print Receipt Last name First name Initials Cardnumber Dough Jonathan D 30292 Access level Activation date 16 04 2005 Deactivation date Usage Count mm0 d 2 Stat
106. rd number in Value Name is optional and is used to distinguish a cardholder s different cards from one another Click OK to enter the card number Value 1234 Mame PO Cancel Copy will enter a new card with a different Value and an activation date of the current date All other parameters will be the same as the selected highlighted card Use the Edit button to edit the description of any card assigned to the cardholder and use the Remove button to delete a card assigned to the cardholder Integra32 User s Guide RBH Access Technologies Inc 92 Chapter 6 Cardholders Profile Tab The profile information like address phone number and email address of a cardholder can be entered in the Profile tab All of this data is optional and does not affect the functioning of the Access Control System Integra32 AxiomLite Cardholders x File E z x de E la Mew Edit Cancel Delete Search Multi Cards F Print Receipt Last name First name Initials Cardnumber Dough Jonathan D Cards Profile Photo Notes More Fields Street fi 3 Some Ad City Anytown Province fo ntara Country Canada Postal LED he Phone F05 555 1 234 Ext E mail jiondough sympatico ca Department ha Department can be selected form the pull down list instead of being typed in RBH Access Technologies Inc Integra32 User s Guide 93 Chapter 6 Cardholders Photo Tab You can select an already saved pi
107. rdholder Rename Control i x Enter New Name Cancel User Mumberl Integra32 User s Guide RBH Access Technologies Inc 132 Chapter 11 Tools Card Import Configure Import Utility The ntegra32 Card Import Utility is used to import cards and cardholder data from a text file into your Integra32 database Card Import utility Oo xj Integra32 Card Import Utility Click to Configure the card import Run Import utility dd Config Import utility 44 View Log File Select Config Import Utility to setup the import parameters 38 This selection is only available if the optional license for the Card Import Utility has been purchased and installed RBH Access Technologies Inc Integra32 User s Guide 133 Chapter 11 Tools Import from a text file Import Wizard A The wizard will help you bo enter bulk data in the card holder table Cards can either be imported From an external text File or MS SOL Server Local machine should have SOL Server running or SQL Client installed C Imports Cards from SQL Server Cancel Back Mex gt Finish E Enter the source and destination paths as well as the delimiting character Click Next Import Wizard g Enter the path to the text file to import into the Cardholders database of Integra32 system Import From C Documents and Settings AdministratoriMy Docu Delimited By Integra32 Database Folder C
108. rs are to be controlled on this elevator You can create up to two elevators per controller by using both the A side and B side readers Integra32 User s Guide RBH Access Technologies Inc 80 Chapter 5 Programming Floor Groups A M caba p E Elevator Floor Groups SE aie E Properties LE add Elevator Floor Group Add Floor Groups as required Change the description and select which floors are to be member of the group Each group can be given an Unlock Schedule so that its floors can have free access during that time L Only fifteen Floor Groups can be created for each elevator im Elevator Floor Groups Elevator Floor Groups Description Cab A end 4th th amp 8th Floors Elevator Cab A Unlock Schedule o Always Available lkems Selected lkems Description Description Tat Floor Cab 4 nd Floor Cab 4 ard Floor Cab 4 4th Floor Cab 4 Bth Floor Cab 4 Ah Floor Cab 4 bth Floor Cab 4 oth Floor Cab 4 Sth Floor Cab 4 10th Floor Cab 4 11th Floor Cab 4 T2th Floor Cab 4 Cancel RBH Access Technologies Inc Integra32 User s Guide 81 Chapter 5 Programming Access Levels Access Levels a ER a peme n i Maste BA Add Access Level Refresh Assigning schedules to access points and floor groups creates access levels They are created so that cardholders can be easily given access rights Before cardholders are entered any additional acc
109. s and Defaults b fn Integras2 Server 4 Integra32 Add Remove Site 4 4 Integra32 Registration ma tae a Integra32 Security System Ga Integra32 Data Restore a Integra32 Database Maintenance i Integra32 Firmware Upgrade 4 4 Restart d Start 4 Stop RBH Access Technologies Inc Chapter 12 Program Groups Integra32 Data Restore Data Restore 1s described at the end of Chapter 10 Integra32 Database Maintenance Running the Database Maintenance will compact and repair the Integra32 databases The Repair will correct most corruptions in the databases Those that can t be repaired will produce an error message Integra32 Firmware Upgrade Before Upgrading 1 Before starting the firmware upgrade be sure to know where the upgrade file rbh 1s located 2 Although upgrading will not affect the panel s memory it is recommended that you download all files to the panel after upgrading to ensure that any new features are properly installed Upgrading After logging in the Upgrade Wizard will come up Browse and select the upgrade file rbh The upgrade file s path will be shown in the box next to the browse button Integra32 Firmware Upgrade Wizard The wizard will guide You through upgrading the firmware of IRC 2000 panels Select the firmware Upgrade file This must be a valid IRC 2000 Firmware upgrade file c TemplIRCt 13DU RBH nie
110. s has been executed at the specified access point In the example below Code Reader Link 1 High Security Mode off for both Reader 1 amp Reader 2 will be executed after a grant access and a key code entry of 1234 on the side A reader of Panel 1 Code reader links are used primarily in HVAC control lighting control and intrusion alarm control systems where it is necessary to control inputs outputs and other access points from a single card read With code reader links the same cardholder can perform different functions at each access point In addition every cardholder can perform a unique function at every access point Further links can have several entries allowing execution of multiple commands at each access point when a card is presented This window contains the following fields and options Integra32 User s Guide RBH Access Technologies Inc 44 Chapter 5 Programming General Reader Options Site codes Alarms Code Reader Links ID Code Description i E 1234 Code Reader Link 1 Reader Side 4 Reader Side E Command Device Duration Schedule Cancel ID The number of the code reader link may be system generated by pressing up and down button or user defined A maximum of 16 code reader links can be generated Code Put in the code number These codes can be in the range of 1 32767 Description The user specified description of link Choose one of the two radio buttons Reade
111. ted A i Door held open warning Door held open alarm Door not open alarm crea o e 8 la SIAL IS JA JA ISA JA A JS JA MKKKKKK KKK KK KKK KKK K Forced entry alarm i Enable printing DWA messages on this machine Defaults Cancel i The user can customize how the system handles messages E g If the user doesn t want a particular message to appear on screen like the Access Requested message it can easily be turned off with a simple click Simply change between Yes and No to stop the display of selected messages on the screen or from being sent to history The user can also send messages to a printer selectable by message Messages can also be sent to ASCII ports ora DVR DVR configuration will be required for this to function correctly Check the box if the DVR or printer are on the local machine Integra32 User s Guide RBH Access Technologies Inc 118 Chapter 9 Options Access Point Activity More Less Hide AP activity olas Grant access Reader Reader 14 Number 38093 Date 30M ar 006 11 40 53 Event Access Granted Mame Melisa Demara She usually wear contact lenses although occationally she mear Glasses The Access Point Activity feature can be used with a CCTV system for video verification To do this enable PC Decision in the Modes tab of the Access Point s Properties window and check Access Point Activity Access R
112. the status of devices will not be affected The first six buttons will bring up Access Points Inputs Outputs Panels Areas and Cardholders respectively The seventh button is used to update verify the status of the items shown Integra32 User s Guide RBH Access Technologies Inc 12 Chapter 3 Monitor Screen How to Execute a Command All operator commands are executed in the same manner 1 Click on the appropriate button on the Device Status Screen toolbar to load the desired devices 2 From the list of items Input Output or Access Point etc select the item s you want to control Clicking on the first item then holding down the Shift key and clicking on the last item in the range can choose a group of items Select non sequential item groups by holding down the Ctrl key and clicking on each desired item 3 Set the command type to permanent semi permanent or timed 4 Right click on the Item s highlighted and then choose a command from the list provided The command is then immediately sent to the appropriate IRC 2000 controller s for execution Command Type From the drop down menu select one of the three options available for command type Permanent Permanent commands are used to perform actions and to manually override system operation When the status of an input output or access point is changed by a permanent command the scheduler no longer controls the device For example if a door is normally ar
113. tors button on the Command Toolbar will display the visiting cardholders and who they are visiting 2 a e C i a BR oa Semi permanent ce Access Input Outputs Panels Areas Visitors z Cardnumber Checkedin Bakewell Joan 725 ee Check Out Device Status Check Out Click Check Out to check out the selected visitor Floors Clicking the Floors button on the Command Toolbar depicts the status of floor outputs on the Device Status Screen g gt E O a amp fg Outputs Panels Areas Cardholders Floors Cab 4 Sth Floor H Cabas Cab A 6th Floor H Cabas Cab A 7th Floor Cab 4 8th Floor Ca A Floor 0 O Unlock bE nd Floor W CabB A Lock Device Status bE 3rd Floor ab E 4th Floor d Unlock Unlock will release the floor button in the cab so that allow anyone may access the floor Lock Lock will energize the floor output and disconnect the floor button in the cab A card with the appropriate access level can release the floor temporarily This selection is only available if the optional license for the Visitor Management System has been purchased and installed Integra32 User s Guide RBH Access Technologies Inc 22 Chapter 3 Monitor Screen Keypad Commands If you have installed a PC100 for Bosch you will have a Keypads icon on the Status button bar Click on this icon to bring up the list of Bosch keypads gt gt
114. us PIN Code Type i Ignore Antipassback Ignore Auto Void i Unlock Privilege 2 High Security Privilege 4 T Link Execute Privilege 3 5 Extended unlock time Disabled El Add Edit Remove Copy Access Level Select previously defined access levels from the pop up window Access levels determine when and where an access code is valid Integra32 User s Guide RBH Access Technologies Inc Chapter 6 Cardholders Activation Date MM DD YYYY This field is automatically populated with the current date and time when a new cardholder is added to the system Deactivation Date MM DD YYYY To deactivate a cardholder enter the current date or a date in the future on which that cardholder is to be deactivated The cardholder will be deactivated automatically on the specified date This field defaults to 1 January 2038 Status Card status is shown here generally active or inactive depending on the activation and deactivation dates This status can be changed to stolen destroyed expired lost or suspended Usage Count Valid range is 1 255 Enter the maximum number of times the card can be used It reduces the count by one every time the card is used at specific readers to gain access When the count reaches zero the card can no longer be used To specify that a card is valid for unlimited number of uses enter 255 Pin Code The PIN Personal Identification Number is the code required at ac
115. using Integra32 A system administrator who updates Integra32 s database The system technician that installs and configures the Integra32 onsite Before reading this guide This guide assumes that you Are familiar and comfortable with a personal computer Know how to use a mouse Are familiar with the Windows operating environment Conventions in this guide Menu options window titles fields and buttons are indicated by italic typeface For example choose Access Point Activity from the Option menu or click Cancel to cancel your changes Keyboard actions and function keys are denoted by bold typeface For example press F1 to display online help Keyboard control sequences i e using two or more keyboard keys in combination are denoted by keys in bold typeface separated by a plus sign For example press Ctrl Alt Delete to reboot the system Cross references are displayed in blue and will jump you to the associated or mentioned part of the manual Click on the cross reference when the curser changes to move to that place in the manual RBH Access Technologies Inc Integra32 User s Guide 1 Chapter 1 Introducing Integra32 Chapter 1 Introducing Integra32 The Integra32 system integrates Access Control Photo Badging Digital Video Recording and Alarm Monitoring into an elegant building management and security system specifically designed for the smaller app
116. y will show a list of cardholders based on your selections You will see the area the cardholder is logged into and the date time they were logged into that area H 2 3 May 2006 11 09 3 May 2006 11 08 a May 2006 11 12 3 May 2006 11 08 3 May 2006 11 13 3 May 2006 11 12 3 May 2006 11 13 1 y or o B 5 Access Inputs Outputs Panels Areas Cardholders Floors ue Humber Lastname Firstname Department Date E 43 Taylor Steve Shipping Shipping E oP 2361 Sc Set fh res Manufacturing Main Office gt 2368 Co AES istina Accounting Main Office E 2od4 Sa dd i Accounting Warehouse A 2395 Go E Print Shipping Shipping 6561 Karm Harpinder Manufacturing Warehouse 14376 Johnston Andrea Manutacturing Warehouse The following commands for areas are available by right clicking the selected cardholder Commands Set Area Set Area is used to change the area that a cardholder is logged into This may be necessary 1f a cardholder get into an area without reading into that area Reset The Reset command will clear the area the cardholder is in The cardholder will not be logged into any area therefore the next card read cannot violate antipassback Print The Print command will produce a printed report showing the data provided in the status pane It will show all of the cardholders displayed and the areas they are in RBH Access Technologies Inc Integra32 User s Guide 21 Chapter 3 Monitor Screen i 14 Visitors Clicking the Visi
Download Pdf Manuals
Related Search
Related Contents
Vialta Beamer TV User's Manual Ford 2006 Freestar Automobile User Manual Triarch 29645 User's Manual Nr.: 11031 BG-CH 18 Li Betriebsanleitung Ch-09 Data Utilities - Natural Broadcast Systems Development of Computer Interface and Data Analysis an2263: PC Master Software: Creation of Advanced Control Pages Actioncam S-50 WiFi Copyright © All rights reserved.