1. Connect When initially going Online with the PAC a popup window will notify you of a project difference between the PAC and the PC Select No Use PC Project Project Differences The project in the PC workspace is not the same as the one in the PAC Do you want to copy the project from the PAC Yes Copy Project From PAC Productivityso Hardware User Manual 4th Edition Rev B i l 17 Chapter 1 Getting Started File Pra Productivity Suite Programming Edit Setup PAC Took Step 6 Open Read Hardware Configuration Before we create a project we must configure the hardware so we ll have the input and output tags With the PAC in STOP Mode select Hardware Configuration under Application Tools and the following screen opens EE a PAC GS Drives EtherNet IP a ss TUL F Hardware Config Security Accounts bn Set PAC Time Date Write Program if Tag Database Ja U0 Ow Local Base Group Base 1 P3 550 Double click the module ta open the module configuration page or if manually adding a module to the system drag the desired module to an open slot and the module s configuration page will open automatically F Discrete Output P3 08TD1S P3 08TD2S P3 167D2 PS 08TAS l1 m 18 f Productivity v Hardware User Manual 4th Edition Rev B Chapter 1 Getting Started This screen shows the user tag names for all eight I O
2. 66040 ncaean sg neve ee ae avew vireo ares 1 27 Step 10 Place PAC in RUN Mode cc ce eee ee ee ee ee ee 1 28 Step 11 Test the Project Using the Monitor Mode 1 29 Chapter 1 Getting Started se MM Introduction Purpose of this Manual Thank you for purchasing the AutomationDirect Productivity3000 Programmable Automation Controller PAC family of products This hardware user manual provides information that will help you install set up program troubleshoot and maintain your Productivity3000 PAC system The manual includes information that is critical to the safety of the personnel who will install and use the controller and to the machinery processes and equipment controlled by the PAC The manual also includes important information about power and signal wiring mounting of the PAC and configuring the PAC system About Getting Started If you are familiar with Programmable Controllers in general then following the simple steps in this first chapter may be all you require to start being productive using a Productivity3000 PAC system After you have completed the steps your Productivity3000 controller will be running the ladder logic project that you programmed Online Help Files and Other Documentation The Productivity3000 programming software Productivity Suite is available as a download from our website See http www aboutplcs com The Productivity Suite software includes s
3. i 4 1 0 Overview Hf NC Edge Contact NCI 1 3A Rung Comments Ft Compare Contact CN 7 Tag Cross a oils Monitor amp Debug a Data View aut Out Coil a Data Logger SET Set Coil PID Tuning oe m A HS Module Testing kst Reset Coil re aL Bit Histogram oR OR Out 3 4 me Word Histogram rus Flasher Ey PAC Error History i a PAC Event History Instructions en Debounce Cail i Control PAC List ime Timed Coil bess rec Toggle Coil el Online d a Choose PAC 7 END Program End 7 Transfer to PAC Nor No Operation Hup Run T D Stop Application Functions Eg Debug ALm Alarm AUG Average CHG Change of Value ran Find Min Max Values Task Management LALM Learn Alarm p 4 HO 6 gt Litt Limit Value W Tasks RMP Ramp Run First Scan Only a ald es gt i Run Every Scan Management GEN Ramp Generator E SCL Scale Linear SCLN Scale Mon Linear Online Help It is essential that you use the Productivity Suite online Help to familiarize yourself with the software Keep it open on your desktop and refer to it frequently as you build your system Click on the toolbar Help button to open the Help file l1 m 12 f Productivitys00 Hardware User Manual 4th Edition Rev B Chapter 1 Getting Started Step 3 Install Hardware The Productivity3000 PAC system components snap together to form a
4. k Select Rung Insert Delete Erase with Cursor Q Find Replace Ctrl F ie eet To Output Ctri W LE mjn BA Paan Ctrl Up ithe Word Histogram tri Doy j x FAC Error History m nino gf PAC Event History 7 i Ctrl Left 4 mn L Ctrl Right Task Management HOOS at Tasks t Scan Ge SIFIFLE TIMER Preset Value Ti SP Curen Value T1 OUR VAL Gane Ti DH NOTE There is also a wire Erase With Cursor tool in the Edit drop down menu that is used to erase any lines that were created using the Wire tools l1 22 f Productivitys00 Hardware User Manual 4th Edition Rev B Chapter 1 Getting Started Next we ll draw a wire to the left Under the Edit drop down menu select Wire then select Left SIFIPLE TIMER Preset Value T1 SPF Cured Value T1CURVAL Gane Ti_OM Next we ll add another normally open contact Place the box cursor on the first position on Rung 1 1 From the Instruction List click amp drag a Contact NO into this box A NO Contact NO dialog box pops up 1 Enter T1_ Manual into the text box 2 Select OK SIFIPLE TIMER Preseli Value Ti 5P Cuman Value T1_OUIRMAL fone Ti_ON NO Contact NO Ti_Manual Show Instruction Comment Monitor Cancel Help The Define Tags dialog box opens Select OK Define Tags The following tags need to be defined String Rows Columns Initial Value Length Bescripten TagName DataType Retentive Input Ti_Man
5. will also install on your computer The evaluation version allows full functionality but is limited to 30 minute sessions Separate database software is required but is not included See our website for more information on DataWorx P3K Choose Yes or No and select Next Productivityso Hardware User Manual 4th Edition Rev B Ii 9 Chapter 1 Getting Started Data or P3K runs on a network PC and acts as a translator between the Productivity PAC and SQL databases enabling seamless database queries and manipulation through use of the PAC s DX ladder instruction Ifyou select Yes DataVVorx P3K will install in evaluation mode from the CD allowing full functionality but limited to 30 minute release Motes sessions Separate database software is required butis not included Install Corniplats Do you want to install DataVWorx P3K C Yes No Previous 8 The next screen to appear contains the Release Notes for this version of the Productivity Suite software Productivity Suite Release Notes Version 1 4 1 1 Lj Apr 19 2011 IMPORTANT NOTICE Using this version of Productivity Suite to save or download a project created with previous versions will alter the project and its functionality as described below Making backup copies of projects is recommended Install Completa Bug Fixed 1 Opening a project would usually result in loss of tags in WX and RX instructions preven
6. 0 Done T1_DN Boolean Preset Value T1_SP Integer 32 Bit l1 20 l Productivity v Hardware User Manual 4th Edition Rev B Chapter 1 Getting Started Place the Box Cursor on the first position on Rung 1 as shown below From the Instruction List scroll to Contact and click amp drag a Contact NO into this box A NO Contact NO dialog box pops up 1 Enter T1_ Start into the text box 2 Select OK SIFIFLE TIMER Preseli Value TSP Cur Value Ti CURYVAL Cane 7104 Ti_Start Show Instruction Comment Monitor Cancel Help The Define Tags dialog box opens Select OK Define Tags The following tags need to be defined ae SEE EEEN ae String aera Description TagName DataType Retentive Lergh Rows Columns Initial Value Input Ti_Start Boolean Cancel Help Productivityso Hardware User Manual 4th Edition Rev B i 1 21 Chapter 1 Getting Started With the cursor in the position to the right of contact T1_Start we are going to begin drawing a branch circuit Under the Edit drop down menu select Wire then select Down Notice that a wire has been added Productivity Suite Programming Software Version 1 6 0 10 No Name ot File Setup PAC Tools Window Help IO g Undo Ctrl Z Rh BS Ctrl V Ctrl X a Copy Ctrl C o DE a i hit Paste Ctrl V Appli i 1 2 a 4 z 6 Tag Database Rung Comments Ctrl
7. 1 2 1 l A ____________ aur 3 Productivityso Hardware User Manual 4th Edition Rev B f 1 2 5 Chapter 1 Getting Started Step 8 Save Project Save the project by opening the File drop down menu and selecting Save Project Productivity Suite Programming Softwa File Edit Setup PAC Tools Wind J New Project f Gl Open Project Close Project Save Project As Import Export Compile Project Transfer Project Page Setup Print Ctrl P Project Properties Bit Histogran l1 26 f Productivitys00 Hardware User Manual 4th Edition Rev B Chapter 1 Getting Started Next we will transfer the project to the PAC Transfer Project is accessed by selecting Transfer Project from the File Menu of the Main Menu Step 9 Write Project to PAC 1 Select To PAC from the Transfer Project menu Productivity Suite Programming Software Version 1 6 0 10 No Name OI File Edit Setup PAC Tools Window Help sec Bes A ate Offline 2 Online 2 Choose P New Project Open Project Close Project T Gol ew Task CHS 9 ale rum Save Project As l amp 3 4 z 6 fi T 5 Import Export Compile Project Fa amp From PAC Transfer Project to PAC ba To USE Drive PAC project is different From USB Drive Exit Bit Histogram Word Histogram rror W The project will then be Tran
8. E USB or Ethernet cable is also required for communications between PC and PAC Productivitys0 Hardware User Manual 4th Edition Rev B i l 5 Chapter 1 Getting Started Step 1 Install Programming Software 1 Download the latest version of the Productivity Suite Programming Software from www productivitypac com Or if the Installation CD is available insert the Productivity Suite Programming Software CD into the PC s CD drive The splash screen should appear after a short time 2 Click on the splash screen s Install button and follow the dialog boxes 3 If the CD does not auto run click your PC s Start menu bottom left corner of screen and select Run or for Windows 7 users type run in the search field to locate this application e Type the following in the Open text field D install exe where D is the drive letter of the CD drive being used or browse to the location of the install exe file that was downloaded and select this file e Select OK and follow the dialog boxes shown through the next pages NOTE See the Productivity Suite Installation and Productivity Suite Startup topics for additional details if needed Carefully read the software license agreement If you agree to the terms and conditions of this agreement select the I accept the terms of this License Agreement and then the Next button w Productivity Suite Programming Software y Installation and
9. GETTING STARTED In This Chapter INCOGUCHION ssrserresrr e Shae 5945 Ge Ree HAGE arneo yy Oo peewee ede lt 1 2 Purpose of this Manual 2224554 0400cdnr teh eoonpn ane aeeitnreus Pay eee aed 1 2 ADOUL GENG Saed 2 4 ban cece ea wae bee ee E E R E es 1 2 Online Help Files and Other Documentation 0 2 aeaaeae 1 2 Technical SUPPOTT sesiapa saa aes oo PAE EAS E E E EE D a a a a 1 2 CONVENTIONS Used 63 a6 5 5 6 2 4 4 4444 e S a a aa aa eee 1 3 Key Topics for Each Chapter acccadecccagaqaet2242 eaaeneese sess od ne5 es 1 3 BEIOre VOU Doiie 5 540494 4004 se0e 5 ae aemns eae net E oer eee 1 4 Productivity Suite System Requirements 2 eee eee eee eee eee 1 5 Step 1 Install Programming Software 0 ce eee eee eee ee eee 1 6 Step 2 Launch Programming Software 0 cece eee ee eee eee 1 11 Onine FEID tnt oaeey ee eee bee oe a Ge eee ea ee owe eee aed bea eee ee 1 12 Steps Install Hardware s 2 2ascatde dene ee tasei es Son a we ee St 1 13 Step 4 Apply Power to PAC 2 4 6 06 064 8 c8ncuicedduees oes es SSeeeue see euee 1 16 Step 5 Establish PC to PAC Communications 0 eee eens 1 17 Step 6 Open Read Hardware Configuration 0 eee eens 1 18 Step 7 Create a Project 22 4 22cch060000 00 ae ee P SOO loose ee ee pee ea sada t 1 20 Step 8 Save Project 22s eeeeds bos ae hak eee eee eases nate eee es 1 26 Step 9 Write Project to PAC cc 6d
10. Use of Productivity Suite Requires Acceptance of the Following License Agreement AUTOMATIONDIRECT COM END USER LICENSE AGREEMENT FOR the Productivity Suite Installing PROGRAMMING SOFTWARE Install Datayore Sorlwyars IMPORTANT Before using this software you should Ral2asa Notas carefully read this agreement The enclosed Productivity Suite Programming computer software programs the Software are the property of Automationdirect com inc or its suppliers Before installing copying downloading accessing or otherwise using this package carefully read this Agreement If you do not accept the terms and conditions of this Agreement you should return the enclosed Software and anv accommanvina items Choose Install Foldar gt O Cnoos2 Shorieuis DBOOOGO Install Completa l1 6 f Productivity v Hardware User Manual 4th Edition Rev B Chapter 1 Getting Started 5 The Choose Install Folder window will open next If this is the first installation of the Productivity Suite Software on your PC the window shown below will open You may accept the default install location or choose a different one using the Browse button The default location is C Program Files AutomationDirect Productivity Suite lt Software Version gt Where Would You Like to Install C Program Files AutomationDirect Productivity Suite 1 4 1 1 Choose Shoricuis T Installing Install DatayYors Somers realease Notes Inst
11. Using Data View the Tag values can be viewed or manipulated for testing the project The Data View window can be accessed by selecting Data View from the Tools Menu of the Main Menu For the Simple Timer Instruction a Monitor button is provided that when selected will load the tags associated with the instruction into Data View Show Instruction Comment Monitor Tags Added a Tag s have been added to data view Don t show this dialog again Productivityso Hardware User Manual 4th Edition Rev B f l 29 Chapter 1 Getting Started mS The tags will be placed in a separate Tab titled New Task STMR as seen below F Ya C gl o w ka e y bI S Displaying 14 00 42 0 Options Autoscale Tagname Mod View As Comment C Offset Booleans T1_CURVAL Decimal Chart Data moa O o S T1 SP Decimal 15 100 20 000 The remaining tagnames in the Ladder Logic can be added to the Data View window by clicking on a blank area in the Tagname column This will display a drop down menu where the tags can be selected Scroll down the list and select the tags to be added spin DHEN S Displaying View As 1 3 0 i Productivitys00 Hardware User Manual 4th Edition Rev B Chapter 1 Getting Started Once all of the tagnames have been added they can now be monitored and manipulated See the Data View help file topic for additional details if nee
12. al 4th Edition Rev B i l 15 Chapter 1 Getting Started Step 4 Apply Power to PAC Ensure proper wiring has been made to the PAC and the correct voltage is available before applying power to the PAC Once this is verified apply power to the PAC The PAC will perform a self evaluation and verification when power is applied See Chapters 2 and 5 of this manual for more power supply and input wiring information yy V GND LOGIC GND 100 240VAC 15 10 24 48VDC 15 20 55 C 50 60 Hz 10 20 60 C l1 es 16 f Productivitys00 Hardware User Manual 4th Edition Rev B Chapter 1 Getting Started nent eee eee Step 5 Establish PC to PAC Communications Select the Choose PAC Icon on the Control PAC Toolbar and the dialog shown below 1 will appear Pra PAC Connections Refresh Done Connectic Device MAC ID User Assigned 3 PAC Add Connection IF Address FAC Source _ Type Part PAC Name Connection p3 550 00 50 c P3550 0 10 10 gt Import Connections Ethernet P3 530 00 50c P3 530 192 168 Auto Disco Available Export Connections Start Blinking CPU Display Stop Blinking CPU Display Change PAC IP Name in the PAC Source column indicates a connection through a non CPU module l Connect Close Help Highlight the PAC listed in the dialog box and select
13. all Complete If the installer detects a previous version of Productivity Suite on your PC then the following window will be displayed in place of the one above A Productivity Suite Programming Software Install Option Install New Insta IO Choose New Folder C Program Files AutomationDirect Productivity Suite 1 4 1 1 Choose Shortcuts Installing Install DaiaWors Sofware Restore Default Browse release Motes Replace Existing Instan Install Cornolais 1 4 0 29 C Program Files AutomationDirect Productivity Suite 1 4 0 29 Change Folder Name C Program Files AutomationDirect Productivity Suite 1 4 1 1 Restore Default Note The existing instance will be uninstalled There are two options available with this Choose Install Folder window a Install a New Instance This option will install a new instance of the Productivity Suite software in the specified folder b Replace the Existing Instance This option allows you to uninstall the previous version of the software and install the new version in its place If this option is chosen the following window appears Click Uninstall to continue Productivityso Hardware User Manual 4th Edition Rev B f l 7 Chapter 1 Getting Started SST SW Uninstall Productivity Suite Programming Software About to uninstall Uninstalling s j J i Productivity Suite Programming Software Uninstall Cornplate This will remove features instal
14. configured PAC in 1 minutes See Chapter 5 Installation and Wiring for more detailed hardware installation information but these are the basic steps 1 Install power supply in the base and engage locking tabs F SSS w SSSESS ANY i N a Locking Tabs 2 Install CPU in the base and engage locking tab 7i SAS Kee Productivityso Hardware User Manual 4th Edition Rev B f l 13 Chapter 1 Getting Started 3 Install I O Modules and engage locking tabs Oe at a oe a oe oa VIVIAN E 4 i 4 Connect appropriate wiring to power supply and I O a P3 01AC and P3 08TAS in this example a a 3 eet r a T I r t ec bebe De pe pees bl F E an Peco i Ej EERENS edd dda In this case The power supply and load are being connected to an AC current source Power Supply l1 ns 14 f Productivity v Hardware User Manual 4th Edition Rev B Chapter 1 Getting Started 5 Connect USB cable P3 550 only Use a standard USB cable with Type A and Type B connectors as shown below If using the P3 530 connect a standard Ethernet cable from the PC to the PAC CPU i Bl Iil lt p aa ee A es r _ G Productivityso Hardware User Manu
15. ded NOTE Force must be enabled for a Tag in the Tag Database before Force can be used in Data View Tags to show in the Editor Show All Discrete Inputs Analog Inputs Integers V SystemData V Bool 7 Discrete Outputs W Analog Outputs W Floats Strings K 2E ver Editor Name Type Ser sce E Gee wen one oe FOOBable L Peak Scan Integ Program M Inted Refresh C Boole Refresh N Boole Requeste String Switch in Boole Switch in 5 Boole T1_CURVAL Integ E Ti_DN Anail ao A Ti SP e T1_Start Boolean gut 18 OZ A e BB DD DY g displaying 14 12 12 0 l Data View 1 New Task STMR Modbus View As Comment Ti_DN a Productivityso Hardware User Manual 4th Edition Rev B f l 3 1 Chapter 1 Getting Started TS Notes 1 3 2 f Productivity v Hardware User Manual 4th Edition Rev B
16. earchable online help topics covering all aspects of the software instruction set module setup and communications In addition each base power supply CPU and I O module includes an installation insert Technical Support We strive to make our manuals the best in the industry We rely on your feedback to let us know if we are reaching our goal If you cannot find the solution to your particular application or if for any reason you need technical assistance please call us at 770 844 4200 Our technical support group will work with you to answer your questions They are available Monday through Friday from 9 00 A M to 6 00 P M Eastern Time We also encourage you to visit our web site where you can find technical and non technical information about our products and our company http www automationdirect com l 2 f Productivitys00 Hardware User Manual 4th Edition Rev B Chapter 1 Getting Started Conventions Used When you see the note pad icon in the left hand margin the paragraph to its immediate right will be a special note Notes represent information that may make your work quicker or more efficient The word NOTE in boldface will mark the beginning of the text When you see the exclamation point icon in the left hand margin the paragraph to its immediate right will be a warning This information could prevent injury loss of property or even death in extreme cases Any warning in thi
17. led by InstallAnywhere It will not remove files and folders created after the installation M Uninstall Productivity Suite Programming Software Please wait while InstallAnywhere s uninstaller removes the following features Files Uninstall Cornplats Shortcuts LaunchAnywhere Folders Registry Cancel 6 Once you have selected the install folder and whether or not to delete any previous instances the Choose Shortcuts window below will appear If a Shortcut Icon is desired for the software select the location where the icon will be created The default location is On the Desktop Once all selections have been made click Install to begin the installation A status window will appear displaying the status of the installation l1 8 f Productivitys00 Hardware User Manual 4th Edition Rev B Chapter 1 Getting Started R Productivity Suite Programming Software Where would you like to create product icons E In the Start Menu Installing 7 On the Desktop Install Datayore Soryyeirs release Motes C In the Quick Lauch Bar Install Completa Icon Name Productivity Suite 1 4 1 1 Restore Default Install DaiaW ort Soityars ralease Notes Install Cornplats 7 Do you want to install DataWorx P3K Software DataWorx P3K runs on a network PC and acts as a translator between the Productivity3000 and SQL databases If you select Yes an evaluation version of DataWorx P3K
18. ormation on Ethernet communication set up procedures AC Power Cord Screwdriver Wire Strippers Hookup Wire DN SS1 DN WS Hookup Wire A e Not available from Automationdirect com l1 f Productivitys00 Hardware User Manual 4th Edition Rev B Chapter 1 Getting Started Productivity Suite System Requirements Productivity Suite Windows based programming software works with Windows XP Home a or Professional Vista Home Basic Premium 32 or 64 bit or Windows 7 Home Professional Ultimate 32 or 64 bit The Productivity Suite Programming Software includes a software installation guide and CD ROM Please check the following requirements when choosing your PC configuration e Windows XP Personal Computer with a 333 MHz or higher processor CPU clock speed recommended Intel Pentium Celeron family or AMD K6 Athlon Duron family or compatible processor recommended e Vista or Windows 7 Personal Computer with a 800 MHz or higher processor CPU clock speed recommended Intel Pentium Celeron family or AMD KG Athlon Duron family or compatible processor recommended e SVGA 1024x768 pixels resolution 1280x1024 pixels resolution recommended e 300MB free hard disk space e RAM Windows XP 128MB free RAM 512MB recommended Vista or Windows 7 512MB free RAM 1GB recommended e CD ROM or DVD drive for installing software from the CD e USB or Ethernet Port for project transfer to PAC iS NOT
19. points Select OK User Tagname DO 0 1 2 1 DO 0 1 2 2 DO 0 1 2 3 DO 0 1 2 4 DO 0 1 2 5 DO 0 1 2 6 DO O 1 2 7 DOH 1 2 8 Status Bit Item User Tagname MSTO L2 1 MST 1 2 2 MS1 0 1 2 3 MST 0 1 2 4 MST 0 1 2 5 MST 0 1 2 6 MST 0 1 2 7 MST 0 1 2 8 Productivityso Hardware User Manual 4th Edition Rev B i 19 Chapter 1 Getting Started IS Step 7 Create a Project Were going to start entering a simple example ladder logic program in the order that follows Rung 1 Place the box cursor on the END position on Rung 1 as shown below From the Instructions List scroll down to Counters Timers and click amp drag a Simple Timer STMR into this box A Simple Timer STMR dialog box pops up 1 Enter 300 0 01 sec timebase into the Preset Value text box for a 3 second preset 2 Enter T1 CURVAL into the Current Value test box 3 Enter T1_DN into the Done text box 4 Select OK P SIMPLE TIMER L P Preset Value Simple Timer STMR Preset Value T1 SP a Current Value T1_CURVAL 0 01 sec Done T1_DN Belay Setting Time Up On Delay timer e ap Done Off Delay timer Show Instruction Comment Monitor Cancel Help The Define Tags dialog box opens Select OK Define Tags The following tags need to be defined String Rows Columns Initial Value Length Description Tag Name Data Type Retentive Current Value T1_CURVAL Integer 32 Bit
20. s 1024 X 786 pixels Click on the New Project in the Start Project dialog box to open a programming window Productivity Suite Programming Software Version 1 6 0 10 No Name Ze a File Edit Setup PAC Tools Window Help EEPE 2 BE Somn w Application Tools Instructions ue Setup Contacts gt i Hardware Config a Security Accounts La Set PAC Time Dat 3 Write Program b Tag Database H Ed I O Overview H a Rung Comments lg Tag Cross Referes AE NO Contact NO dt NC Contact NC 44 NO Edge Contact NO aft NC Edge Contact NCI L 53 Compare Contact CM _ i Coils J Monitor amp Debug Dead Proj E Data View Lj New Project 4 Open Project f iii Aa w SEN pv g Data Logger SET Set Coil bee PID Tunin a HS ea ty a Hed Bit Histogram Iw aia j as Word Histogram rs Flasher PAC Error History Ming PAC Eugi nen Debounce Coil Productivityso Hardware User Manual 4th Edition Rev B f l 11 Chapter 1 Getting Started The Programming Window is divided into menus and toolbars that work together to make project development as simple as possible Tv TENT ee ees Be Sars an Er Hardware Config Jee o Bei fase gt G Bit Pe Pi Security Accounts 4 3 6 mt ao Le Set PAC Time Date 4 H NC Contact NC gt i a diner Application ft NO Edge Contact NO Tag Database Togs l
21. s manual should be regarded as critical information that should be read in its entirety The word WARNING in boldface will mark the beginning of the text Key Topics for Each Chapter The beginning of each chapter will list the key topics that can be found in that chapter Getting Started HAPTER In This Chapter Introduction Purpose of this Manual About Getting Started Supplemental Manuals and Other Help Technical Support Conventions Used Productivitys0 Hardware User Manual 4th Edition Rev B f 1 3 Chapter 1 Getting Started mS Before you begin It is recommended that the following items be available to make this short step by step introduction to the Productivity3000 PAC go smoothly Example Productivity3000 System P3 03B Base 7 i 2 a i P3 FILL Module N P3 08TAS Output Module P3 16SIM Module f et D P3 01AC or P3 01D0 7 Power Supply Pitti EESTE or a i a P3 550 CPU Module P3 530 CPU Module is also available zZ u USB A to USB B Programming Cable PC Running Productivity Suite Vista or Windows 7 Programming Software sy P3 550 only P3 PGMSW rel 41 Sagi J PPh a ebaee i a SP i 4 diem Not available from If using the P3 530 CPU then Automationdirect com Download software from use an Ethernet cable for our webste at programming Refer to the help www productivitypac com file for inf
22. sferred to the PAC from the PC During the transfer a status window will open displaying the process Transfer Project To PAC Compile Transfer Done Status In Progress Productivityso Hardware User Manual 4th Edition Rev B i 1 27 Chapter 1 Getting Started Step 10 Place PAC in RUN Mode Next verify the Run Stop switch on the PAC CPU is placed to the Run position and then place the PAC in RUN mode on the Control PAC Toolbar so the ladder logic program executes Pra Productivity Surte Programming Software Version 1 6 0 10 No Nang File Edit Setup PAC Tools Window Help OOUOS oa nalg D Offiine 2 Online 2 Choose PAC I es 1 New Task 3 8 5 Hla Be m NOTE Ifthe Run Stop switch on the PAC is in the Stop position the Run button on the Control PAC Toolbar will be disabled m Debug 28 f Productivitys00 Hardware User Manual 4th Edition Rev B Chapter 1 Getting Started Step 11 Test the Project Using Monitor Mode In this next step use the Monitor Mode and Data View to test the ladder logic program Select 1 Monitor Mode from the top of the Ladder Logic screen to display the status of Boolean and Integer Tags New Task Ee Ea bile am E j z gt o Run Every Scan T Ee j 1 2 3 4 5 6 7 a q 10 E Ti_Stat SIMPLE TIMER 1 E Tire Up Preset Value T1_SP Current Value Ti_CURVAL On Delay Done T1_DN T1_htanual 1 1 FF
23. ting compile and transfer to PAC Tags would need to be re entered to repair project 2172 Previous bas Congratulations Productivity Suite 1 4 1 1 has been successfully installed to C Program Files AutomationDirect iProductivity Suite 1 4 1 1 Press Done to install USB driver and close the installer 9 The Installation is now complete Select Done l 1 0 Productivitys0 Hardware User Manual 4th Edition Rev B Chapter 1 Getting Started i SSE Step 2 Launch Programming Software After installing the Productivity Suite Programming Software P3 PGMSW launch the software by double clicking the desktop Productivity Suite Icon Or from the PC s start menu slide the mouse pointer through the menus start gt All Programs gt AutomationDirect gt Productivity Suite x x x x gt Productivity Suite to the Productivity Suite Programming Software selection and use the left mouse button to click on it ult Accessories do AutomationDirect Computer Productivity Suite 1 6 0 10 L Control Panel pauserm Pra Productivity Suite Devices and Printers readme Uninstall Productivity Suite ul AutomationDirect Tools d Games Help and Support Default Programs 4 Back The Productivity Suite Programming Software will start up and display the Main Window as shown here NOTE The recommended minimum screen size for the Productivity Suite Software i
24. ual Boolean Cancel Help Productivityso Hardware User Manual 4th Edition Rev B i 1 23 Chapter 1 Getting Started ss Rung 2 Next we ll add another normally open contact at the start of rung 2 Click amp drag a Contact NO into this box A NO Contact NO dialog box pops up 1 In the text box scroll down and select T1_DN 2 Select OK Ti_San SIMPLE TIMER Prei Value Ti 5P Curen Value Ti CURYAL Dane Ti_DH Ti_Wanual 4h NO Contact NQ a EMD Refresh Critical Error Log mo J Refresh Non Critical Error Log Switch in Run Bit jo Switch in Stop Bit Help EMD T1_Manual Tl SP Next we ll add an Out coil at the end of the rung Place the cursor at the end of the rung and from the Instructions list drag amp drop an Out Coil OUT An Out Coil OUT dialog box pops up 1 In the text box scroll down and select DO 0 1 2 1 2 Select OK SIFIPLE TIFIEP Preseli Value Ti SP Cume Value T1 OURVAL Dor T1048 T1_Manual Out Coil OUT 2 4 f Productivitys00 Hardware User Manual 4th Edition Rev B Chapter 1 Getting Started The ladder program now looks like this When either of the T1 contacts are energized the timer starts When it times out contact T1_DN energizes and turns on the rung 2 output Ti_Stan SIMPLE TIMER Prese Value Ti SP Cuman Value T1_CURVAL Dane TiD Ti_MHanal OO 0

Download Pdf Manuals

image

Related Search

Related Contents

Final Report to the NCPTT - RIT MAGIC Center  呼吸代謝測定装置 Vmaxスペクトラシリーズ    VS15 BP USER MANUAL  取扱説明書 - アピックスインターナショナル  SEIKI SC371TS User's Manual  OpenTSTOOL User Manual - Third Institute of Physics  MANAGER`S CHAIR FAUTEUIL DE DIRECTION  Notice Pocket  Felicidades por comprar el teléfono avanzado y compacto LG  