Home
SGR-3/1 - blaubergventilatoren.de
Contents
1. SENSOR SPEED SWITCH SGR 3 1 OPERATION MANUAL BLAUBERG Ventilatoren SGR 3 1 www blaubergventilatoren de BLAUBERG Ventilatoren GmbH is happy to offer your attention the sensor mechanical damages speed switch SGR 3 1 Store the delivered speed switch in the manufacturer s original packing box in a dry ventilated premise INTRODUCTION The storage environment must not be subjected to any aggressive and or chemical evaporations admixtures foreign objects that may provoke corrosion and damage connection tightness Store the speed switch in an environment with minimized risk of The present operation manual contains technical description technical data sheets operation and mounting guidelines safety precautions and warnings for safe and correct operation of the speed switch mechanical damages temperature and humidity fluctuations Read carefully the operation manual especially the safety requirements Store the delivered speed switch at the ambient temperature from 5 C before mounting and start up of the device up to 40 C Keep the operation manual available as long as you use the device MANUFACTURER S WARRANTY GENERAL The speed switch complies with the requirements according to the EU norms and directives to the relevant EU Low Voltage Equipment Directives EU Directives on Electromagnetic Compatibility We hereby declare that the following product complies with the essential protection requirements of Elect
2. ght g 50 60 Hz V load A section mm mee Ea Ense PA Astin 0 1 SGR 3 1 110 24 1 0 35 le ae nn IP30 138 up to 45 up to 80 operations BLAUBERG Ventilatoren Model Voltage Max current Cable cross www blaubergventilatoren de Fig 1 Overall dimensions MOUNTING WARNING Make sure that the speed switch is not damaged Do not use a damaged switch Do not install the switch on an uneven surface While tightening the screws avoid overtightening not to damage the device CONNECTION TO POWER MAINS WARNING Cut off power supply to the speed switch prior to any operations with the speed switch All mounting and servicing operations are allowed for duly qualified electricians with valid electrical work permit for electric operations after careful study of the present user s manual For connection of the speed switch to ventilation units follow the wiring diagram fig 3 CONTROL Touch a respective speed button to activate the required speed of the connected ventilation equipment fig 4 Touch a respective speed button to change the selected speed Touch a current speed button to turn the ventilation equipment off The respective speed button has blue highlighting Fig 2 SGR 3 1 Speed switch mounting Mounting sequence of the sensor speed switch fig 2 1 Carefully undo the latches of the switch front panel with a screwdriver 2 Remove the fro
3. nt panel 3 Route the cable to the installation place of the speed switch 4 Fix the back panel to the wall through the fixing holes 5 Install the speed switch front panel on the latches 1 speed 110 240 V 50 60 Hz OUT OUT OUT OUT IN L4 L3 L2 L1 L Input Voltage 110 240 V Output current 1A M1 ventilation equipment Wiring diagram Fig 4 Speed switch control BLAUBERG Ventilatoren ACCEPTANCE CERTIFICATE The sensor speed switch SGR 3 1 ms is recognizes as serviceable The speed switch complies with the requirements according to the EU norms and directives to the relevant EU Low Voltage Equipment Directives EU Directives on Electromagnetic Compatibility We hereby declare that the following product complies with the essential protection requirements of Electromagnetic Council Directive 2004 108 EC 89 336 EEC and Low Voltage Directive 2006 95 EC 73 23 EEC and CE marking Directive 93 68 EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility This certificate is issued following test carried out on samples of the product referred to above Approval mark Manufacturing date WARRANTY CARD PGR SELLER SALES DATE REPRESENTATIVE IN EU BLAUBERG Ventilatoren GmbH Aidenbachstr 52a D 81379 Munich Germany BLAUBERG Ventilatoren www blaubergventilatoren de SGR 3 1 v 1 1 09 2013 EN
4. romagnetic Council Directive 2004 108 EC 89 336 EEC and Low Voltage Directive 2006 95 EC 73 23 EEC and SAFETY RULES CE marking Directive 93 68 EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility The manufacturer hereby warrants normal operation of the speed switch over the period of 1 year from the retail sale date provided observance of the installation and operation regulations In case of failure due to manufacturing fault during the warranty period the consumer has the right for the speed switch repair or exchange The replacement is offered by the Seller If case of no confirmation of the sale date the warranty period shall be calculated from the manufacturing date The manufacturer shall not be liable for any damage resulting from any speed switch misuse of or gross mechanical interference with the speed switch The manufacturer is not responsible for the damages resulted due to the use of third party equipment or to third party equipment Transportation is allowed by any vehicle provided the speed switch is transported in the original package and is protected against weather and The sensor speed switch SGR 3 1 is designed for switching on off and speed switching of multi speed ventilation units and domestic fans The speed switch is equipped with a sensor panel with three buttons for speed selection The speed switch complies with the requirements according to the EU norms and direc
5. tives to the relevant EU Low Voltage Equipment Directives EU Directives on Electromagnetic Compatibility Cut off power supply to the speed switch prior to any operations All mounting and maintenance operations must be carried out by duly qualified electricians with a valid electrical work permit for electric operations after careful study of the present user s manual Misuse of the speed switch or any unauthorized modification are not allowed Follow the manual guidelines to ensure trouble free operation and long service life of the soeed switch IN WARNING en The speed switch is not allowed for use by children and persons with reduced physical mental or sensory capacities without proper practical Do not dispose in domestic waste The product contains in part material that can be recycled and in part substances that should not end up as domestic waste Dispose of the product once it has reached the end ofits working life according to theregulations valid in your country experience or expertise unless they are controlled or instructed on the product operation by the person s responsible for their safety Supervise the children and do not let them play with the product DELIVERY SET Y Sensor speed switch SGR 3 1 Y Operation manual Y Packing box v Fasteners TECHNICAL DATA Table 1 Technical data Parameters Operating Operating Ingress temperature humidity Service life Protection Wei