1. THANK YOU FOR COMPLETING THIS FORM Information will be held confidential WARRANTY REGISTRATION IMPORTANT We urge you to fill out your warranty registration card within fourteen 14 days of date of purchase You can also register your warranty on the internet at www ghpgroupinc com Complete the entire serial number Retain this portion of the card for your records GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 G P Tel 877 447 4768 group maa WWW ghpgroupinc com SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207
2. INDOOR OUTDOOR PRODUCTS KEROSENE PORTABLE FORCED AIR HEATERS USER S MANUAL AND OPERATING INSTRUCTIONS cm ANSI A10 10 1998 COMPLIES WITH UL733 AND CAN CSA B140 0 03 AND CSA B140 8 1967 MODEL KFASOH KFA75H KFA125H KFA210H Before the first use of this heater please read this USER S MANUAL very carefully This USER S MANUAL has been designed to instruct you as to the proper manner in which to assemble maintain store and most importantly how to operate the heater in a safe and efficient manner Please keep this manual for future reference CONSUMER Retain this manual for future reference Questions problems missing parts Before returning to your retailer call our customer service department at 877 447 4768 8 30 a m 4 30 pm CST Monday Friday or email us at customerservice ghpgroupinc com NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING A DANGER IMPROPER USE OF THIS HEATER CAN RESULT IN SERIOUS INJURY OR DEATH FROM BURNS FIRE EXPLOSION ELECTRICAL SHOCK AND OR CARBON MONOXIDE POISONING A WARNINGS 1 RISK OF INDOOR AIR POLLUTION e Use this heater only in well ventilated areas Provide at least a three square foot 2 800 sq cm opening of fresh outside air for each 100 000 BTU hr of heater rating e People with breathing problems should consult a physician before using the heater e Carbon monoxide poiso
3. NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 2 ASSEMBLY For KFA50H 75H Models only Tools Required e Medium Phillips Screwdriver 1 Assembling Handle amp Cord Wrap 1 Lift front guard for arrow direction and make sure that guard s wedged portion fits into the slit hole on the upper housing 2 Align the holes in the upper housing with ttwo mounting holes on the handle as shown in Figure 6 3 Secure handel with Screws with provided 4 Insert card wrap into the rectangle holes on the supportor and align the hole on the cord wrap with the mounting hole on the side cover as shown in Figure 6 KFA75H Model only 5 Secure cord wrap with Screws with provided For KFA125H 210H Models only Tools Required e Medium Phillips Screwdriver 3 4 inch socket or adjustable wrench 1 Assembling Handle amp Wheel and Cord Wrap 1 Slide threaded axle through the rear section of the wheel support frane 2 Slide one axle bushing on to each side of the axle Slide one wheel on to each side of the axle Attach one cap nut on to each side of the threaded axle and tighten well 3 Place heater on wheel support frame Align the holes on fuel tank flange with holes on wheel support frame 4 Position the Handles on top of fuel tank flange Insert screws through handles fuel tank flange and wheel support frames as shown in Figure 8 and attach nut finger tight after each screw is inserted 5 Align the hole on the handles with the mounting ho
4. NOTICE The major electrical components of this heater are protected by a safety fuse mounted to the PCB board If your heater fails to start check this fuse first and replace as necessary You should also check your power source to insure that proper voltage and frequency are being supplied to the heater TO STOP HEATER 1 Turn switch to OFF and unplug power cord TO RESTART HEATER 1 Wait 10 seconds after stopping heater 2 Repeat steps under to start heater EXTRA ELECTRIC OUTLET amp PIGGYBACK POWER CORD A WARNING SHOCK HAZARD KAZE e Always cover electric outlet when not in use BS 4 si e Don t plug and use a appliance more than 120V 60Hz 5A DOW current in this outlet LOUVER KFA210H Model Only A CAUTION RISK OF BURN Louver is Extremely Hot in operation and after shut off Never touch or control angle while operating or still Hot Louver s angle can be controlled by turning handle in direction of arrow as shown in Figure 10 Control range Up 28 Down 20 8 LONG TERM STORAGE OF YOUR HEATER FUEL TANK DRAIN 1 Drain fuel tank through fuel cap opening For KFA50H 75H Models Only 2 Remove fuel drain bolt from rear bottom side of fuel tank using 3 4 socket or adjustable wrench and drain For KFA125H 210H Models Only See Figure 11 3 Using a small amount of kerosene swirl and rinse the inside of the tank NEVER mix water with the kerosene as it will cause rust inside the tank Pour the kerose
5. S MANUAL ITEM PAGE PRECAUTIONS SAFETY GUIDE ne 1 Te INIRODUCTION secs RE reer eed ce EE EE eine 2 PRATURES aa oo GA AAAA AA O A E REAL EE an 9 3 UNPACKING AND ASSEMBLY mmens tri 4 4 KEROSENE l K OR NO I FUEL On 6 5 OVERVIEW OF HEATER DESIGN sa ot a tienda 7 6 FUELING YOUR HEATER memnnnennnnnznizninzttinir tnin itineranti 8 7 el ENN e IEN 8 8 LONG TERM STORAGE OF YOUR HEATER cocci 9 9 MAINTENANCE seess 10 10 REPLACING FUSE EE 14 11 TROUBLE SHOOTING GUIDE A O O A A AE 15 12 WIRING DIAGRAM www 16 13 SPECIFICATIONS wasi oo GO a EA Aaa OO aa 17 14 EXPLODED PARTS DRAWING ue ooo O ORO i O AA 18 amp 21 15 PARTS LIST wew a i i a divine A OW idee A taa 19 206 22 23 1 INTRODUCTION Please read this USER S MANUAL carefully It will show you how to assemble maintain and operate the heater safely and efficiently to obtain full benefits from its many built in features Is FEATURES Front Guard Hot Air Outlet SE SE Upper Shell Lower Shell Fan Guard Cord Wrap 75H Model Only Fuel Tank Side Cover Pressure Gauge 75H Model Only Fuel Gauge Fuel Cap Lamp Thermostot Knob 75H Model Only LED Power Reset Switch 75H Model Only Power Cord Piggy Back 75H Model Only Figure 1 KFA50H KFA75H MODELS 2 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING Front Handle Hot Air Outlet Shell Lower Power Cord P
6. A N A 170 000 Fuel Consumption HIGH 0 38 1 44 0 57 2 16 0 95 3 60 1 60 6 06 Gal Hr r Hr LOW N A N A N A 1 30 4 92 Fuel Tank Capacity Gal 1 5 0 18 9 5 0 18 9 10 0 37 9 13 0 49 2 Pump Pressure PSI kgt HIGH 3 8 0 27 3 8 0 27 5 5 0 39 8 5 0 60 LOW N A N A N A 6 5 0 46 Volt Hz 120Vac 60Hz 120Vac 60Hz 120Vac 60Hz 120Vac 60Hz Amps 1 6 1 6 2 5 3 7 Phase 1 1 1 1 A 21279 Sp nass Weight Lbs 26 9 12 2 26 9 12 2 54 5 24 7 63 3 28 7 17 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 14 EXPLODED PARTS DRAWING KFA50H 75H 125H Models Only NOTE SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS BURNER HEAD ASSEMBLY 18 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 15 PARTS LIST KFA50H 75H 125H Models Only PART NO AR PORE KFASOH KFA75H KFAI2SH 1 Quantity 1 Fuel Tank Assmebly 2151 0026 00 2151 0027 00 2151 0028 00 l 2 Fuel Drain Bolt 4329 0072 00 1 3 Fuel Gauge 2156 0047 00 2156 0049 00 2156 0050 00 1 4 Fuel Filter Assmbly 2155 0005 00 2155 0005 00 2155 0001 00 1 5 Fuel Cap 2151 0003 00 2151 0003 00 2151 0003 00 1 6 Cord Bushing 3712 0013 00 3712 0013 00 3712 0013 00 1 7 Power Cord 3980 003 1 00 3980 0177 00 3980 0177 00 1 8 Thermistor 38C0 0054 00 38C0 0054 00 38C0 0054 00 1 9 Button Support 3713 0048 00 2 1
7. TO THE STORE Please follow the simple instruction below to inspect and change the fuse PROCEDURE FOR REPLACING FUSE A WARNING SHOCK HAZARD To prevent personal injury unplug the power cord before replacing fuse 1 Unplug heater 2 Remove side cover screws using medium phillips screw driver 3 Disconnect switch wires from power switch 4 Remove fuse from fuse holder See Figure 22 5 Replace fuse with enclosed fuse A WARNING FIRE HAZARD To avoid fire Do not substitute with a higher or lower current rating 6 Replace switch wires to power switch Fuse Holder 7 Replace side cover NOTE Specified fuse rating AC 125 8A KFA50H Model Figure 22 Replacing Fuse 14 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 11 TROUBLE SHOOTING GUIDE TROUBLE Heater ignites but MAIN PCB assembly shuts heater off after a short period of time Indicator Lamp is flickering and room temp display indicates E1 POSSIBLE CAUSE Wrong pump pressure Dirty Air Output Air Intake or Lint Filter Dirty Fuel Filter Dirt in Nozzle Dirty Photocell Lens Photocell Assembly not Properly installed Not seeing the flame Bad electrical connection between photocell and MAIN PCB assembly Defective Photocell CORRECTIVE ACTION 1 See Pump Pressure Adjustment Page 13 2 See Air Output Air intake and Lint Filters page 10 See Fuel Filter Page 13 See Nozzl
8. electronic ignitor sends voltage to a specially designed spark plug The spark plug ignites the fuel and air mixture described above The Air System The heavy duty motor turns a fan that forces air into and around the combustion chamber Here the air is heated and then forced out the front of the heater The Safety System A Temperature Limit Control This heater is equipped with a Temperature Limit Control designed to turn off the heater should the internal temperature rise to an unsafe level If this device activates and turns your heater off it may require service Internal Shut Off Temp Reset Temperature MODELS Plus Minus 10 Degrees Plus Minus 10 Degrees KFAS0H 75H 176 F 80 C 122 F 50 C KFA125H 230 F 110 C 194 F 90 C KFA210H 194 F 90 C 140 F 60 C Once the temperature falls below the reset temperature you will be able to start your heater B Electrical System Protection This heaters electrical system is protected by a fuse mounted to the PCB assembly that protects it and other electrical components from damage If your heater fails to operate check this fuse first and replace as needed FUSE TYPE All Models 125 volt 8 amps C Flame Out Sensor Utilizes a photocell to monitor the flame in burn chamber during normal operation It will cause the heater to shut off should the burner flame extinguish NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 6 FUELING YOUR HEATER NEVER FILL THE HEATER FU
9. em Era POWER MP BLACK GRAN zma BLACK PUMP CD peb Rea v i GREENT CAPACITOR THERMOSTAT TEMP CONTROL CN2 AC2 EM Ka GN1 AG1 BLK CN5 CN6 R BLACK BLUE PHOTO ROOM w CELL BLACK RAO BLUE S TSWE CAPACITOR UNT ars COLOR POWER CONTROL BLACK SWITCH YELLOW 57 5 BLACK ZM RED 15UF 230VAC BLACK 20uF 350VAC BLACK WHITE AG120V 60Hz HITE GREEN EARTH C WIRING DIAGRAM KFA210H Model CONTROL PCB LACK BLACK SPARK PLUG e obt gt POWER LAMP BAI LED ORANGE BLACK CN3 reo dam GREEN CAPACITOR 20uF 350VAC THERNOSTAT TEMP CONTROL EN2 AE2 MHT EARTH N1 AC1 BIKEES CN5 een BLUE x PBP vox NNO me EE LIMIT Fr POWER CONTROL TBA 4 25VAC SWITCH YELLOW 5 e BLACK aw KA Fi z i BLACK TD GREEN WHITE WHITE LI e ELECTRIC iz JEW i OUTLET on EARTH 16 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 13 SPECIFICATIONS 16 5 419mm KFA125H KFA210H 38 4 976 mq 44 6 1 132esn 21 5 547 ma 23 1 587 m 35 5 902 px 36 6 929 rx KFA125H KFA210H Models MODEL KFA50H KFA75H KFA125H KFA210H HIGH 50 000 15 000 125 000 210 000 BTU Ht LOW N A N
10. in transit Freight charges on warranty parts or heaters to and from the factory shall be the responsibility of the owner E En R This warranty does not imply or assume any responsibility for consequential damages that may result from the use misuse or the lack of routine maintenance of this heating appliance A cleaning fee and the cost of parts may be charged for appliance failures resulting from lack of maintenance This warranty does not cover claims which do not involve defective workmanship or materials FAILURE TO PERFORM GENERAL MAINTENANCE INCLUDING CLEANING WILL VOID THIS WARRANTY THIS LIMITED WARRANTY IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE THE REMEDY PROVIDED IN THIS WARRANTY IS EXCLUSIVE AND IS GRANTED IN LIEU OF ALL OTHER REMEDIES IN NO EVENT WILL GHP GROUP INC BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you CLAIMS HANDLED AS FOLLOWS 1 Contact your retailer and explain the problem 2 Ifthe retailer is unable to resolve the problem contact our Customer Service Dept detailing the heater model the problem and pr
11. through face of nozzle ONE this will remove any dirt in nozzle W Reinstall nozzle into nozzle adaptor until nozzle seats Tighten 1 3 turn more using 5 8 socket wrench Nozzle Face 40 45 inch pounds Nozzle Adaptor Reinstall nozzle adaptor to burner bracket Reinstall spark plug to nozzle adaptor Attach ignitor wire to spark plug Attach fuel and air line hoses to nozzle adaptor Reinstall fan blade and upper shell Spark Plug ozzle Adaptor Nozzle Adaptor Combustion Chamber Screw Ignitor Wire Spark Plug Nozzle Adaptor Bracket Burner Air Line ZL EN Nozzle Adaptor Figure 16 Nozzle Replacement 11 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING F SPARK PLUG CLEAN AND REGAP EVERY 600 HOURS OPERATION OR REPLACE AS NEEDED For KFA50H 75H 125H Models Only Remove upper shell See page 10 Remove fan See page 10 Remove ignitor wire from spark plug gt Ignitor Wire Remove spark plug from nozzle adaptor using medium Nozzle Adaptor phillips screwdriver Spark Plug Clean and regap spark plug electrodes to 3 5mm gap 0 138 Reinstall spark plug to nozzle adaptor Attach ignitor wire to spark plug Reinstall fan and upper shell For KFA210H Model Only Remove upper shell See page 10 6 Remove fan See page 10 LAT J jk Remove ignitor wire from nozzle adaptor A J Remove spark plug from nozzle adaptor using medium Nozzle Adaptor Ly
12. using medium Phillips screwdriver Lift upper shell off Remove fan guard Wash or replace air intake filter Reinstall fan guard and upper shell C AIR OUTPUT FILTER LINT FILTER REPLACE EVERY 500 HOURS OF OPERATION OR ONCE A YEAR Remove upper shell and fan guard See Air Intake Filter Turn Air pressure gauge counter clock wise and remove Remove end filter cover screws using medium Phillips screwdriver Remove end filter cover Replace air output and lint filter Reinstall end filter cover and air pressure gauge Lint Filter Reinstall fan guard and upper shell Pressure Gauge D FAN BLADES Figure 13 Air Output Filter Access CLEAN EVERY SEASON OR AS NEEDED Remove upper shell See Air Intake Filter Use M6 Allen wrench to loosen set screw Motor Shaft which holds fan blade to motor shaft Slip fan blade off motor shaft Clean fan blade using a soft cloth moistened with kerosene or solvent Dry fan blade thoroughly Reinstall fan blade on motor shaft Place fan blade hub flush with end of motor shaft Place set screw on flat of shaft Tighten set screw firmly 40 50 inch pounds 4 5 5 6 N m Reinstall upper shell Set Screw Figure 14 Fan Assembly 10 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING E NOZZLE REMOVE DIRT IN NOZZLE AS NEEDED SEE PAGE 16 Combustion Chamber For KFA50H 75H 125H Models Only TM Screw Remove upper shell See page 10
13. 0 Display P C B Assembly 215A 0013 00 l 11 Shell Lower 3111 0343 03 3111 0343 03 3111 0344 03 1 12 Flange Screw 4319 0015 00 4319 0015 00 4319 0015 00 4 13 Clip Nut 3131 0182 00 3131 0182 00 3131 0182 00 8 14 Bushing Grommet S 3231 0120 00 3231 0120 00 3231 0120 00 1 15 Bushing Grommet L 3231 0121 00 3231 0121 00 3231 0121 00 1 16 Air Line 3341 0021 00 3341 0021 00 3341 0002 00 1 17 Temperature Limit Assembly 2153 0022 00 2153 0022 00 2153 0023 00 l 18 Flange Screw 4319 0015 00 4319 0015 00 4319 0015 00 1 19 Chamber Assembly 2152 0115 00 2152 0116 00 2152 0117 00 1 20 Bracket Photocell 3131 0159 00 3131 0159 00 3131 0159 00 1 21 Screw BH1 4311 0068 00 4311 0068 00 4311 0068 00 1 22 Photocell Assembly SP KFA1007 SP KFA1007 SP KFA1007 1 23 Burner Head Assembly 2152 0120 00 2152 0121 00 2152 0122 00 1 23 1 Burner Head 3531 0026 00 3531 0026 00 3531 0025 00 1 23 2 Nozzle SP KFA1026 SP KFA1027 SP KFA1003 1 23 3 Washer Nozzle Seal 4349 0016 00 4349 0016 00 4349 0016 00 2 23 4 Spring Nozzle Seal 3431 0010 00 3431 0010 00 3431 0010 00 1 23 5 O Ring 3311 0002 00 3311 0002 00 3311 0002 00 1 23 6 Nozzle Adaptor 3231 0178 00 3231 0178 00 3231 0179 00 1 23 7 Spark Plug SP KFA1008 SP KFA1008 SP KFA1009 1 23 8 Bolt Flange 4329 0079 00 4329 0079 00 4329 0079 00 1 24 Flange Screw 4319 0015 00 4319 0015 00 4319 0015 00 3 25 Fuel Line 3341 0024 00 3341 0024 00 3341 0025 00 1 26 Motor and Pump Assemblv 2154 0078 00 2154 0078 00 2154 0079 00
14. 0077 00 1 24 1 Motor 3970 0213 00 1 24 2 Capacitor 3820 0258 00 1 24 3 Supportor Motor 3121 0482 00 1 24 4 Nut Hex 4331 0022 00 2 24 5 Holder Capacitor 3231 0180 00 1 24 6 Pump Body 3541 0050 00 1 24 7 Bolt BH Special 4321 0198 00 2 24 8 Rotor See SP KFA 1022 1 24 9 Blade See SP KFA1022 4 24 10 Insert See SP KFA 1022 1 24 11 End Pump Cover 353 l 0027 00 l 22 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 15 PARTS LIST KFA210H Model Only PARTNO KEV NO DESCRIPTION KFA210H Quantity 24 12 Elbow 3231 0181 00 1 24 13 Lint Filter See SP KFA 1005 1 24 14 Bolt Flange 4329 0016 00 6 24 15 Output Filter See SP KFA 1005 1 24 16 End Filter Cover 3221 0076 00 1 24 17 Ball See SP KFA1010 2 24 18 Spring See SP KFA1010 2 24 19 Adjusting Screw See SP KFA1010 2 24 20 Bolt Flange 4329 0016 00 4 24 21 Intake Filter See SP KFA 1005 1 25 Fan Assemblv 2154 0007 00 1 26 Bolt Headless Hex Socket 4323 0004 00 1 27 Pressure Gauge 3740 0049 00 1 28 BTU Control Switch 2154 0070 00 1 29 Main P C B Assembly 215A 0047 00 1 30 Screw TH2S 4312 0046 00 2 31 Ignitor 39E0 0014 00 1 32 Side Cover Right 3121 0499 01 1 33 Power Switch 39A0 0191 00 1 34 Window Displav 323 1 0113 00 1 35 Flange Screw 4319 0015 00 4 36 Side Cover Left 3121 0329 00 1 37 Electirc Outlet Assembly 39D0 0263 00 1 38 Cover Outlet 323 1 0
15. 1 26 1 Motor 3970 0210 00 3970 0210 00 3970 0211 00 1 26 2 Capacitor 3820 0257 00 3820 0257 00 3820 0258 00 1 26 3 Motor Support 3121 0481 00 3121 0481 00 3121 0482 00 1 26 4 Nut Hex 4331 0022 00 4331 0022 00 4331 0022 00 2 26 5 Holder Capacitor 3231 0182 00 1 26 6 Pump Body 3541 0022 00 3541 0022 00 3541 0022 00 1 26 7 Bolt BH Special 4321 0198 00 4321 0198 00 4321 0198 00 2 19 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 15 PARTS LIST KFA50H 75H 125H Models Only PART NO FOR TECHNICAL ASSISTANCE SEE YOUR LOCAL RETAILER OR CONTACT US AT Phone 1 877 447 4768 20 KEY NO DESCRIPTION KFASOH KFA75H KFA125H Quantity 26 8 Rotor See SP KFA1000 See SP KFA1000 See SP KFA1000 1 26 9 Blade See SP KFA1000 See SP KFA1000 See SP KFA1000 4 26 10 Insert See SP KFA1000 See SP KFA1000 See SP KFA1000 1 26 11 End Pump Cover 3531 0027 00 3531 0027 00 3531 0027 00 1 26 12 Elbow 3231 0181 00 3231 0181 00 3231 0181 00 1 26 13 Lint Filter See SP KFA1005 See SP KFA1005 See SP KFA1005 l 26 14 Bolt Flange 4329 0016 00 4329 0016 00 4329 0016 00 6 26 15 Output Filter See SP KFA1005 See SP KFA1005 See SP KFA1005 1 26 16 End Filter Cover 3221 0029 00 3221 0029 00 3221 0029 00 1 26 17 Ball See SP KFA1006 See SP KFA1006 See SP KFA1006 1 26 18 Spring
16. 1 14 00 1 39 Screw Top Table 4319 0042 00 1 40 Flange Screw 4319 0015 00 4 41 Shell Upper 3111 0352 01 1 42 Fan Guard 3561 0078 00 1 43 Bushing Fan Guard 3351 0010 00 3 H Flange Screw 4319 0015 00 8 KEY NO DESCRIPTION KFA210H Quantity 1 Rotor kit SP KFA1022 1 2 Filter kit SP KFA1005 1 3 Plug Pump adjuster kit SP KFA1010 2 FOR TECHNICAL ASSISTANCE SEE YOUR LOCAL RETAILER OR CONTACT US AT Phone 1 877 447 4768 23 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 15 PARTS LIST WHEELS AND HANDLE 1 KFASOH KFA75H MODELS DESCRIPTION Handle 3231 0073 00 3231 0073 00 Cord Wrap 3221 0041 00 Hardware Kit HW KFA1001 2 KFA125H KFA210H MODELS HW KFA1001 KEY NO DESCRIPTION a Quantity KFA125H KFA210H 1 Front Handle 3551 0023 00 3551 0022 00 1 2 Rear Handle 3551 0080 00 3551 0081 00 1 3 Wheel Support Frame 3551 0082 00 3551 0084 00 1 4 Wheel 3720 0018 00 3720 0018 00 2 5 Threaded Axle 3551 0088 00 3551 0089 00 1 6 Cord Wrap 3221 0042 00 322 1 0042 00 2 7 Hardware Kit HW KFA1016 HW KFA1016 1 7 1 Screw INCLUDED IN HARDWARE KIT INCLUDED IN HARDWARE KIT 8 7 2 Flange Screw INCLUDED IN HARDWARE KIT INCLUDED IN HARDWARE KIT 4 7 3 Cap Nut S INCLUDED IN HARDWARE KIT INCLUDED IN HARDWARE KIT 4 1 4 Nut INCLUDED IN HARDWARE KIT INCLUDED IN HARDWARE KIT 8 1 5 Bushing INCLUDED IN HARDWARE KIT INCLUD
17. ED IN HARDWARE KIT 2 1 6 Cap Nut L INCLUDED IN HARDWARE KIT INCLUDED IN HARDWARE KIT 2 8 Louver 2156 0043 00 1 Warranty LIMITED WARRANTY This limited warranty is extended to the original retail purchaser of this Forced Air Convection Radiant Heater and warrants against any defect in materials and workmanship for a period of one 1 year from the date of retail sale GHP Group Inc at it s option will either provide replacement parts or replace or repair the unit when properly returned to the retailer where purchased or one of our service centers as directed by GHP Group Inc within one 1 year of retail purchase Shipping costs labour costs etc are the responsibility of the purchaser DUTIES OF THE OWNER This heating appliance must be operated in accordance with the written instructions furnished with this heater This warranty shall not excuse the owner from properly maintaining this heater in accordance with the written instructions furnished with this heater A bill of sale canceled check or payment record must be kept to verify purchase date and establish warranty period Original carton should be kept in case of warranty return of unit WHAT IS NOT COVERED 1 Damage resulting from use of improper fuel Damage caused by misuse or use contrary to the owners manual and safety guidelines Damage caused by a lack of normal maintenance Fuses Use of non standard parts or accessories Damage caused
18. EL TANK IN THE LIVING SPACE FILL THE TANK OUTDOORS DO NOT OVERFILL YOUR HEATER AND BE SURE HEATER IS LEVELED IMPORTANT NOTICE REGARDING FIRST IGNITION OF HEATER The first time you light the heater it should be done outdoors This allows the oils etc used in manufacturing the heater to burn off outside A WARNING NEVER REFILL HEATER FUEL TANK WHEN HEATER IS OPERATING OR STILL HOT 7 OPERATION A VENTILATION B RISK OF INDOOR AIR POLLUTION USE HEATER ONLY IN WELL VENTILATED AREAS Provide a fresh air opening of at least three square feet 2 800 sq cm for each 100 000 BTU Hr rating Provide extra fresh air if more heaters are being used Example A KFA210H heater requires one of the following e a two car garage door raised six inches 15 24 cm e a single car garage door raised nine inches 22 86 cm e two thirty inch 76 20 cm windows raised fifteen inches 38 1 cm OPERATION TO START HEATER 1 Fill fuel tank with kerosene or No 1 fuel oil 2 Attach fuel cap 3 Plug power cord of heater into three prong grounded extension cord Extension cord must be at least six feet long Extension Cord Wire Size Requirements e 6 to 100 feet 1 8 to 30 5 meters long use 16 AWG conductor e 101 to 200 feet 30 8 to 61 meters long use 14 AWG conductor 4 Turn THERMOSTAT CONTROL Knob to desired setting Setting range 40 F 110 F KFA75H 125H 210H Models Only 5 Push BTU control Switch to desired level High or
19. LOW KFA210H Model only See Figure 8 6 Push Power Switch to ON position Power Indicator Lamp will light and heater will start NOTE Room Temperature display explanations are as follows KFA125H 210H Models only When the room temperature is less 0 F the LED display will show Lo When room temp is between 0 F and 99 F the number shown on the display is the current room temperature When room temperature is greater than 99 F the LED display will show Hi If heater does not start the thermostat setting may be too low turn thermostat Control Knob to higher position to start heater If heater still does not start turn power switch to OFF and then to ON position If heater still does not start see Troubleshootiong Guide on page15 NOTE User can Select to operate the heater on two different BTU levels High or Low The BTU level can be selected before turning the unit on or while it is in operation by pushing the BTU control switch Room Temp Display BTU Control Switch BTU Control Switch Lamp i Pushto HIGH e i Wy unt DK La i H Push to LOW LOW l Thermostat LED Power Thermostat LED Power Lake l Control Knob Switch Control Knob Switch e i i 75H Model Only B A E KFA50H 75H Models KFA125H 210H Models Fan Guard Figure 8 Controls for All Models 8 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING
20. PARTS DRAWING KFA 210H Model Onl NOTE SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS BURNER HEAD ASSEMBLY 21 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 15 PARTS LIST KFA210H Model Only PART NO KEY NO DESCRIPTION KFA210H Quantity 1 Fuel Tank Assmebly 2151 0029 00 1 2 Fuel Drain Bolt 4329 0072 00 1 3 Fuel Gauge 2156 0052 00 1 4 Fuel Filter Assmbly 2155 0001 00 1 5 Fuel Cap 2151 0003 00 1 6 Cord Bushing 3712 0013 00 1 7 Power Cord 3980 0179 00 1 8 Thermistor 38C0 0054 00 1 9 Shell Lower 3111 0351 01 1 10 Flange Screw 4319 0015 00 4 11 Clip Nut 3131 0182 00 8 12 Bushing Grommet S 3231 0120 00 1 13 Bushing Grommet L 3231 0121 00 1 14 Air Line 3341 0002 00 1 15 Temperature Limit Assembly 2153 0024 00 1 16 Flange Screw 4319 0015 00 1 17 Chamber Assemblv 2152 0119 00 1 18 Bracket Photocell 3131 0159 00 1 19 Screw BH1 4311 0068 00 2 20 Photocell Assembly SP KFA1007 1 21 Burner Head Assembly 2152 0124 00 1 21 1 Bracket Burner 3121 0477 00 1 21 2 Nozzle SP KFA1011 1 2l 3 Washer Nozzle Seal 4349 0016 00 1 214 Spring Nozzle Seal 3431 0010 00 1 21 5 O Ring 331 1 0002 00 1 2l 6 Nozzle Adaptor 3231 0180 00 1 2l 7 Spark Plug SP KFA1021 1 2l 8 Bolt Flange 4329 0079 00 l 22 Flange Screw 4319 0015 00 4 23 Fuel Line 3341 0019 00 1 24 Motor and Pump Assembly 2154
21. See SP KFA1006 See SP KFA1006 See SP KFA1006 1 26 19 Adjusting Screw See SP KFA1006 See SP KFA1006 See SP KFA1006 1 26 20 Bolt Flange 4329 0016 00 4329 0016 00 4329 0016 00 4 26 21 Intake Filter See SP KFA 1005 See SP KFA1005 See SP KFA 1005 1 27 Fan Assembly 2154 0009 00 2154 0009 00 2154 0004 00 1 28 Bolt Headless Hex Socket 4323 0004 00 4323 0004 00 4323 0004 00 1 29 Pressure Gauge 3740 0049 00 3740 0049 00 1 30 Main P C B Assemblv 215A 0048 00 215A 0046 00 215A 0047 00 1 31 Screw TH2S 4312 0046 00 4312 0046 00 4312 0046 00 2 32 Ignitor 39E0 0008 00 39E0 0008 00 39E0 0005 00 1 33 Side Cover Right 3121 0496 00 3121 0497 01 3121 0498 01 1 34 Power Switch 39A0 0191 00 39A0 0191 00 39A0 0191 00 1 35 Window Displav 3231 0113 00 l 36 Flange Screw 4319 0015 00 4319 0015 00 4319 0015 00 4 37 Side Cover Left 3121 0190 00 3121 0350 00 3121 0352 00 1 38 Flange Screw 4319 0015 00 4319 0015 00 4319 0015 00 4 39 Shell Upper 3111 0347 03 3111 0347 03 3111 0348 03 1 40 Clip Nut 3131 0182 00 3131 0182 00 2 4 Fan Guard 3221 0050 00 3221 0050 00 3221 0051 00 1 42 Flange Screw 4319 0015 00 4319 0015 00 4319 0015 00 8 43 Front Guard 3561 0066 00 3561 0066 00 1 KEV NO DESCRIPTION KFASOH KFA75H KFA125H Quantity l Rotor kit SP KFA1000 SP KFA1000 SP KFA1000 I 2 Filter kit SP KFA1005 SP KFA1005 SP KFA1005 1 3 Plug Pump adjuster kit SP KFA1006 SP KFA 1006 SP KFA 1006 l NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 14 EXPLODED
22. a A Ignitor Wire Remove fan blade See page 10 AI NM GRE Remove fuel and air line hoses from nozzle adaptor Remove ignitor wire from spark plug Remove spark plug from nozzle adaptor using medium phillips screwdriver Bumer Head Turn nozzle adaptor 1 9 turn 40 to counter clock wise and pull toward motor to remove See Figure 15 Place plastic hex body into vise and lightlry tighten Carefully remove nozzle from nozzle adaptor using 5 8 socket wrench Blow compressed air through face of nozzle this will remove any dirt in nozzle Reinstall nozzle into nozzle adaptor until nozzle seats Tighten 1 3 turn more using 5 8 socket wrench 40 45 inch pounds Reinstall nozzle adaptor to burner head Reinstall spark plug to nozzle adaptor Attach ignitor wire to spark plug Attach fuel and air line hoses to nozzle adaptor Reinstall fan blade and upper shell For KFA210H Model Only Remove upper shell See page 10 Remove fan See page 10 Remove fuel and air line hoses from nozzle adaptor Remove ignitor wire from spark plug Remove spark plug from nozzle adaptor using medium phillips screwdriver Turn nozzle adaptor 1 8 turn 45 to counter clock wise and pull toward motor to remove See Figure 16 Fuel Line Place plastic hex body into vise and lightly tighten Carefully remove nozzle from nozzle adaptor using 5 8 SR socket wrench roy Blow compressed air
23. comodate any added contaminants that may be added to the heated space KEROSENE SHOULD ONLY BE STORED INA BLUE CONTAINER THAT IS CLEARLY MARKED KEROSENE NEVER STORE KEROSENE IN A RED CONTAINER Red containers are associated with gasoline NEVER store kerosene in the living space Kerosene should be stored in a well ventilated place outside the living area NEVER use any fuel other than 1 K kerosene 1 diesel and 1 oil are acceptable substitutes NEVER use fuel such as gasoline benzene alcohol white gas camp stove fuel paint thinners or other oil compounds in this heater These are volatile fuels that can cause an explosion or uncontrolled flames NEVER store kerosene in direct sunlight or near a source of heat NEVER use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 5 OVERVIEW OF HEATERS DESIGN Fuel System This heater is equipped with an electric i air pump that forces air through the air m line connected to the fuel intake and then min through a nozzle in the burner head d e 5 When the air passes in front of the fuel R Va intake it causes fuel to rise from the tank i and into the burner nozzle This fuel and l Ge air mixture is then sprayed into the combustion chamber in a fine mist Sure Fire Ignition The
24. dicates E3 Room Temp sensor disconnected Sensor Failure Thermostat switch failure Reconnect sensor See Wiring diagram Page 16 Replace sensor See Wiring diagram Page 16 Replace switch See Wiring diagram Page 16 Heater will not turn on Indicator Lamp is off Temperature limit safety device is overheated No electrical power Blown fuse 4 Bad electrical connection between temperature limit safety device and PCB board 15 Turn power switch to OFF and allow to cool about 10 min Check to insure heater cord and extension cord are plugged in Check power supply Replace safety fuse in PCB board Check electrical connections See Wiring Diagram Page 16 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 12 WIRING DIAGRAM A WIRING DIAGRAM KFASOH Model DISPLAY PCB CONTROL PCB ent CN2 BLACK PHOTO CELL 3 BLACK POWER SWITCH LIMIT POWER CONTROL CN3 CN7 BLACK 7 AA BLACK SPARK PLUG RED i g 3 7 BLACK ORANGE a BLACK RED ware CAPACITOR 15uF 230VAC PUMP MOTOI GREEN PW W HE PW BLK EE EARTH FUSE BA 125VAC o a Caw AC120V 60Hz B WIRING DIAGRAM KFA75H 125H Models CONTROL PCB Z BLACH SPARK PLUG e
25. e Page 11 Clean Photocell Lens Page 12 Make sure photocell boot is properly seated in bracket Page 12 Check electrical components See wiring diagram Page 16 Replace Photocell Page 12 Heater will not ignite but motor runs for a short period of time Indicator Lamp is flickering and room temp display indicates E1 No fuel in tank 2 Wrong pump pressure Carbon deposits on spark plug and or improper gap Dirty fuel filter Dirt in Nozzle Water in fuel tank Bad electrical connection between ignitor and MAIN PCB assembly Ignition wire is not attached to spark plug Fill tank with kerosene See Pump Pressure Adjustment Page 13 See Spark Plug Page 12 See Fuel Filter Page 13 See Nozzle Page 11 Flush fuel tank with clean kerosene Page 9 Check electrical components See wiring diagram Page 16 Attach ignition wire to spark plug See Spark Plug Page 12 Fan does not turn when heater is plugged in and power switch was in the ON Position Indicator Lamp is on or flickering Thermostat setting is too low Bad electrical connection between motor and MAIN PCB assembly Turn thermostat control knob to a higher setting Check electrical connections See Wiring Diagram Page 16 Indicator Lamp is flickering and room temp display indicates E2 Indicator Lamp is flickering and room temp display in
26. iggy Back Room Temp Display LED Power Reset Switch Fuel Gauge A Puer Gap SS 4 Side Cover LISS SSS GAA Pressure Gauge Lamp Aa ON N 772 AN Fan Guard Thermostat Knob ZZ V 10 Flat Free Wheel Fuel Drain Bolt Figure 2 KFA125H MODEL Electric Outlet Louver R Handl Kl Hot Air Outlet kie Shell Lower ja L A Cord Wrap Fuel Gauge Fuel Cap BTU Control Switch Side Cover Pressure Gauge Fan Guard Power Cord Piggv Back Thermostat Knob Room Temp Displav LED Power Reset Switch 10 Flat Free Wheel Fuel Drain Bolt Figure 3 KFA210H MODEL 3 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 3 UNPACKING AND ASSEMBLY 1 REMOVE THE HEATER AND ALL PACKING MATERIALS FROM THE BOX Fig 4 and 5 NOTE Save the shipping carton and packing materials for future storage KFA125H KFA210H Wheel Support Frame d Yes Yes Wheel Yes Yes Threaded Axle Yes Yes Front Handle Yes Yes Rear Handle Handle Cord Wrap Hardware kit HW KFA1001 Hardware kit HW KFA1016 Figure 4 KFA50H KFA75H MODELS salgaj ees Cord Wraps Hardware Kit KFA75H Model Fonty HW KFA1001 Figure 5 KFA125H KFA210H MODELS Screws Flange Screws MINI 7 Nuts Cap Nuts S Bushings Cap Nuts L 888 38 888989 B Q OD Hardware Kit HW KFA1016 Front Handle Rear Handle Wheel Support Frame LAW Louver KFA210H Model Only b f mae Axle 10 Flat Free Cord Wraps
27. ith clean fuel and replace in tank Attach fuel line to fuel filter neck Replace switch wires to power switch Reinstall side cover I PUMP PRESSURE ADJUSTMENT Flat blade NOTE If the pump pressure needs to be adjusted Screw driver make sure the heater is running on the HIGH BTU setting End Filter Cover Push the BTU CONTROL Switch to HIGH Pressure Gauge Plug See Operation page 8 KFA210H Model only Pressure Gauge Remove Pressure Gauge Plug from End Filter Cover Install accessory Pressure Gauge KFA50H Model only Start heater See Operation page 8 Allow motor to reach full speed Adjust pressure Using a flat blade screwdriver Turn relief valve to clockwise to increase pressure Turn relief valve to counter clockwise to decreasepressure Stop heater See Operation page 8 Pump Pressure MODEL High BTU level Low BTU od KFA75H 125H Models Only KFA50H 3 8 psi N A Pressure Gauge KFA75H 3 8 psi N A KFA125H 5 5 psi N A KFA210H 8 5 psi 6 5 psi BTU Control Switch NOTE USE ONLY ORIGINAL EQUIPMENT REPLACEMENT PARTS Use of alternate or third party components will void any warranty and may cause unsafe KFA210H Model Only operating condition Relief Valve Figure 21 Adjusting Pump Pressure 13 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 10 REPLACING FUSE NOTICE This heater is fuse protected If your heater fails to ignite DO NOT RETURN YOUR HEATER
28. le on the Cord Wrap Insert Screws through Cord Wrap handles and attach nut finger tight after each screw is inserted 6 After all screws are inserted tighten nuts firmly Figure 6 Assembling Handle amp Cord Wrap 2 Assembling Louver KFA210H Model only 1 Remove two screw in each side fore end of upper shell 2 Fit Bracket Right amp Left to each side flange of upper shell and align the each hole on the brackets with the hole on the flanges See Figure 7 Page 6 3 Secure each hole with a screw that removed NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING Rear Handle Lamm Cord Wrap X Z Flange Screw Fuel Tank Flange Air Inlet Wheel Support Frame Nut Wheel Wheel Bushing Cap Nut L Figure 7 Assembling Handle Wheel and Cord wrap Louver A CAUTION DO NOT OPERATE heater without support frame assembled to tank NOTE Heater should be inspected before each use and at least annually by a qualitied service person 4 KEROSENE 1 K For optimal performance of this heater it is strongly suggested that l K kerosene be used l K kerosene has been refined to virtually eliminate contaminants such as sulpher Which can cause a rotten egg odor during the operation of the heater However 1 diesel fuel oil may also be used if 1 K kerosene is not available Be advised that these fuels do not burn as clean as l K kerosene and care should be taken to provide more fresh air ventilation to ac
29. ls away from heater Bulk fuel storage should be a minimum of 25 ft from heaters torches portable generators or other sources of ignition All fuel storage should be in accordance with federal state or local authorities having jurisdiction 3 RISK OF ELECTRIC SHOCK e Use only the electrical power voltage and frequency specified on the model plate of the heater e Use only a three prong grounded outlet and extension cord e ALWAYS install the heater so that it is not directly exposed to water spray rain dripping water or wind e ALWAYS unplug the heater when not in use PROPOSITION 65 WARNING Fuels used in gas wood burning or oil fired appliances and the products of combustion of such fuels contain chemicals known to the State of California to cause cancer birth defects and other reproductive harm MASSACHUSETTS RESIDENTS Massachusetts state law prohibits the use of this heater in any building which is used in whole or in part for human habitation Use of this heating device in Massachusetts requires local fire dept permit M E L C 148 Section 10A CANADIAN RESIDENTS Use of this heater shall be in accordance with authorities having jurisdiction and CSA Standard B139 NEW YORK CITY RESIDENTS For use only at construction sites in accordance with applicable NYC codes under NYCFD certificate of approval 5034 and 5037 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING CONTENTS OF USER
30. ne out making sure that you remove it all IMPORTANT Do not store kerosene over summer months for use during next heating season Using old fuel could damage heater 4 Reinstall fuel cap Properly dispose of old and dirty fuel For KFA50H 75H Models Only 5 Reinstall Fuel Drain Bolt to Fuel tank and tighten firmly using 3 4 socket or adjustable wrench For KFA125H 210H Models Only See Figure 11 IMPORTANT Before reinstalling the fuel drain bolt make sure the seal is on the bolt If the seal is not used the bolt cannot be installed correctly and the fuel tank will leak Figure 10 Louver Angle Control Fuel Drain Bolt Figure 11 Drain Bolt 6 Store heater in dry well ventilated area Make sure storage place is free of dust and corrosive fumes 7 Store the heater in the original box with the original packing material and keep the USER S MANUAL with the heater 9 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING 9 MAINTENANCE A WARNING NEVER SERVICE HEATER WHILE IT IS PLUGGED IN OR WHILE HOT USE ORIGINAL EQUIPMENT REPLACEMENT PARTS Use of third party or other alternate components will void warranty and may cause unsafe operating conditions A FUEL TANK Screw Upper Shell FLUSH EVERY 200 HOURS OF OPERATION OR i l AS NEEDED SEE STORAGE PAGE 9 L Air Intake Filter B AIR INTAKE FILTER WASH AND DRY WITH SOAP AND WATER EVERY 500 HOURS OF OPERATION OR AS NEEDED Remove screws along each side of heater
31. ning Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness and or nausea If you have these signs the heater may not be working properly Get fresh air at once Have the heater serviced Some people are more affected by carbon monoxide than others These include pregnant women persons with heart or lung disease or anemia those under the influence of alcohol or those at high altitudes e Never use this heater in living or sleeping areas 2 RISK OF BURNS FIRE EXPLOSION e NEVER use any fuel other than l K kerosene 1 disel fuel oil in this heater e NEVER use fuel such as gasoline benzene paint thinners or other oil compounds in this heater RISK OF FIRE OR EXPLOSION e NEVER use this heater where flammable vapors may be present e NEVER refill the heaters fuel tank while heater is operating or is still hot A C Al I ION Hot while in operation Do not touch Keep children clothing and combustibles away from heater Minimum Clearances Outlet 8 feet 250cm Sides top and rear 4 feet 125cm NEVER block air inlet rear or air outlet front of heater NEVER use duct work in front or behind of heater NEVER move handle service a hot operating or plugged in heater NEVER transport heater with fuel in it s tank When used with an optional thermostat or if equipped with a thermostat heater may start at any time ALWAYS locate heater on a stable and level surface ALWAYS keep children and anima
32. oof of date of purchase 3 Arepresentative will contact you DO NOT RETURN THE HEATER TO GHP GROUP INC unless instructed by our Representative This warranty gives you specific legal rights and you may also have other rights which vary from state to state TO REGISTER THE WARRANTY ON YOUR HEATER PLEASE FILL OUT THIS CARD COMPLETELY AND MAIL WITHIN 14 DAYS FROM DATE OF PURCHASE OR REGISTER ON LINE AT www ghpgroupinc com NAME PHONE EMAIL ADDRESS CITY STATE ZIP MODEL SERIAL DATE PURCHASED DEALER PURCHASED FROM TYPE OF STORE CITY amp STATE WHERE PURCHASED PRICE PAID Please Take a Minute To Give Us Your Answers To The Following Questions All Responses Are Used Solely For Market Research And Are Held In Strict Confidence Who primarily decided this purchase O Male C Female I 18 24 O 25 39 140 59 C 60 and over Purpose of Purchase Do you own any other portable heaters DI Yes LI No If yes type brand How do you intend to use your new heater LI Construction Site LI Farm Warehouse Commercial LI Garage Outbuilding LI Other How did you become aware of this heater LI In Store Display Newspaper Ad Magazine Ad LI Friend Relative O TV Commercial O Store Salesperson O Other What made you select this heater DI Style DI Size Portability Price DI Package O Brand Other Do you CO own O rent Would you recommend this heater to a friend O Yes O No Please give us your comments
33. phillips screwdriver e Clean and regap spark plug electrodes to 3 5mm gap 0 1387 Relnstall spark plug to nozzle adaptor Attach ignitor wire to spark plug Reinstall fan and upper shell AssiN CLEAN PHOTOCELL ANNUALLY OR AS NEEDED Remove upper shell See page 10 Remove fan See page 10 Remove photocell from it s mounting Clean photocell lens with cotton swab TO REPLACE Remove side cover screws using medium phillips screwdriver Disconnect switch wires from power switch and remove side cover A Photocell Disconnect wires from circuit board and remove Une photocell Ba Bracket Install new photocell and connect wires to circuit ef Photocell board Lens Screw Switch ires Replace switch wires to power switch and side cover net Photos Replace fan and upper shell ai Incorrect ik Correct Figure 19 Photocell Replacement 12 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING H FUEL FILTER i Fuel Filter CLEAN OR REPLACE TWICE A HEATING Fuel line SEASON OR AS NEED Remove side cover screws using medium phillips screwdriver Disconnect switch wires from power switch and remove side cover Pull fuel line off fuel filter neck Turn fuel filter 90 to counter clockwise and pull to remove KFA50H 75H Models only Turn fuel filter 90 to clockwise and pull to remove KFA125H 210H Models only Wash fuel filter w