Home
User`s manual of Plastic Sewer Manholes and Inspection Chambers
Contents
1. Base element is a bottom unit of each manhole inspection chamber The inner diameter is 315 425 600 or 1000 mm Several standard types of the base elements are manufactured The diameters DN of connections and outlet are the same The main connection the 1 connection and up to two side connections the 20d and 3 connections can be connected into the base element With respect to outlet the axe angle may be 90 to 270 clockwise A linear manhole has the axe angle of 1st connection of 180 Counter direction of the inlet junctions is inadmissible Level difference of the outlet bottom grade line and that of the individual inlets bottoms marked delta h is for plastic base elements insignificant or 0 mm Outlet is a sewer piping through which the waste water flows out of the manhole outlet pipe is mouthed into the base element The piping profiles range from DN 110 to DN 450 The piping materials are smooth PVC ULTRA RIB 1 ULTRA RIB 2 ULTRA RIB 1 DIN a ULTRA RIB 2 DIN The 1st connection main is a sewer piping through which wastewater flows into the manhole inspection chamber mouthed into the base element Selection of material and DN are similar as with the outlet With respect to outlet the axe angle connection may be 90 to 270 clockwise A linear manhole inspection chamber has the primary inlet angle of 180 Counter direction of the connection junctions is inadmissible The 2nd connection is further secon
2. Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual In a table located in the bottom part of the screen there are synoptically displayed the particular print outputs table of manholes inspection chambers table of base elements table of drop manholes and in situ table of cover table of atypical base elements The data in the tables are not active and they cannot be corrected directly in the tables All the corrections must be carried out in the editing dialog The corrections are projected into tables immediately 6 9 Editing dialog ae 0 x id Data manhole inspection chamber data 53 seg Identit Base elemelev Ground elev Difference Height Optimal height 2 53 152 00 158 00 6 00 6 00 6 00 m ite Manholes DM 1000 flexible connection G E individual ii g Manhole super elevation over the ground assembly gg 70 Vehicular and pedestrian roads h 0 An open ground A 15 h 0 00 M anhole inspection chamber bedding Floor reinforced concrete slab sand bedding l Base element DN 200 or Order code l Without cover Order code AF720000 w MFS2021 0 Lol cast iron cover C250 Atypical Cover bedding Pipe material and pipe type concretering Senne PVE smooth l without connect Finish of cover Suroundings i Main connection Ange 1 150 o t w CS m Identification of the
3. 2 Requirements for hardware and software installation The PLASTIC SEWER MANHOLES AND INSPECTION CHAMBERS 2005 program of the WINPLAN SW package is designed for the MS Windows 98 and higher PC operation systems The program has no special demands on hardware The graphic card should enable operation of Windows with at least 800 x 600 resolution at 16 colours The installation to hard disc from the attached CD is run automatically by the SETUP EXE installation program which is easily started by a double click of the left mouse button on program name in the File manager or in the Explorer The Install Shield Wizard will lead you through the installation You would be asked to select and prove the program location and the program folder The Wizard offers a standard setting which is satisfactory in a majority of cases 3 Initial description of the program The PLASTIC SEWER MANHOLES AND INSPECTION CHAMBERS 2005 program is intended for design of plastic sewer manholes and inspection chambers produced by the Wavin company Downloading of relevant data from the Sewer System longitudinal profile program of the WINPLAN SW system data files is possible The main purpose of the program is to create the model drawings of a selected type of sewer manholes and inspection chambers manhole and inspection chamber assembly schemes created by the program table of manhole and inspection chamber elements table of dropo manhole elements and
4. in situ connections table of base elements and covers These tables comprise the detailed data for the parts elements ordering and for detailed design of the projects Further the program enables to create an order of the shaft elements including covers The full version enables also loading of relevant data from the files of longitudinal profile within the WINPLAN system User s interface of the program is divided into 4 parts The main roll down menu with the program title with quick access keys buttons and manufacturer selection Left hand panel where all the manholes are synoptically shown in all open data files Table in bottom part of a screen with detailed data of each manhole table of manholes table of base elements Editing dialog with data of the currently designed manhole and its schematic sketch The program enables working with more files simultaneously Each file has an own editing window with data and schematic sketch of the currently designed manhole Switching among them is possible no WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual either via the View main menu by selection of relevant window or by clicking of the left mouse button at any manhole of the required file in the left hand panel or by clicking of the right mouse button at file name The user also may select the editing windows arrangement into tiles or cascade in the View menu an
5. 1 EU CO O e E E E a eons eaee anette oeee 11 6 Description of menus buttons and dialog windows COMMANGCG c seccccceseceeseececeeeeeeceecesseeeesaueeeesaeeeeas 12 6 1 A EEPE E EE A E EI EE E A I A E ET AE AA AN lanieeee 13 6 2 BE E I EEA AE NE E E E EE AA E E E E E A EAE E E ete cgi A TEE 17 6 3 TOS NONI e E A A EE AEE A A AEE A 20 6 4 VACW AO senei a e E E E E E E nd A oges EER E AEO EE ease T EE AE EER 27 6 5 FOD geste r E EE E E E EE EAE EE AERE AEE EE oe hac nce E EE ANETE EAA E 29 6 6 Manufacturer of manholes and inspection chambers 1 sccccccccccceesseececsanussecessanuseeesessansnsaeseessanuaanesessaauaaanseessaaaaaanss 30 6 7 Left hand side list of manholes inspection chambers files ccccccccccsssssseseeseseeeeecesecseaaaauaeeesseeeecessssseasaaaaaeeeeseeseesenaas 30 6 8 EE a E EAEN EAO EE E E N TAE A A E ET T nena ne S IAE E E E A ET E E ES 31 6 9 OTA AO PEIRE E AA EP E E I A IAE A AE E 32 7 Description and general rules of sewer manholes assembly cccccsseeeecseeeeeseeeeeceeeeeeeeeeeeeaeeeeseeeeeeseeeeeens 34 ANS mo WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual at eea WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual 1 Foreword Dear friends the PLASTIC SEWER MANHOLES AND INSPECTION CHAMBERS 2005 v 2 0 program which comes to your hands is the new version of program which complements popular and ab
6. by a humus cover and grass sowing As a rule in a road the cover vicinity is identical with composition of the road or also the granite pavement is used Manhole height Inspection chamber height Under manhole height the difference between the cover and outlet piping internal bottom levels is understood It is equal to sum of construction heights of all used elements while the base element height is taken from the outlet bottom level only At location of a manhole inspection chamber in a road it is necessary to seat the cover onto the telescopic extender or bearing ring cone to be able to rectify the cover elevation precisely Height of fill is a minimum super elevation of the manhole inspection chamber cover above the surrounding ground Height of 500 mm is designed as a standard The program enables to submit any real height from 0 mm Manhole inspection chamber identification is name of a manhole inspection chamber which may be submitted arbitrarily acc to need of particular sewer designs Outputs The outputs comprise the model drawings table of manholes table of base elements table of manhole inspection chamber sets table of covers table of drop manholes and in situ order of shaft elements incl covers sets of manholes inspection chambers Optionally it is possible to print everything or the selected parts of outputs only Model manhole inspection chamber drawing is an enclosure of a sewer design documentation w
7. corresponding editing dialog All changes of the manhole inspection chamber data are immediately projected into all tables The current manhole may be changed anytime by mouse pointing and clicking to its identification in the left hand panel or by pressing of the Previous manhole inspection chamber or Next manhole inspection chamber quick access keys With the current shaft the program enables to return in submitting to arbitrary preceding step Undo and Redo buttons Once the current manhole is replaced with another all sequence preceding submitting steps is deleted The user may possibly change the set of elements of automatically assembled manhole inspection chamber after ticking the Individual assembly box in the editing dialog The user may arbitrarily change sequence and assembly of elements of manhole inspection chamber in dialog individual manhole inspection chamber assembly The program checks the link between individual components only Similarly the height of manhole shaft of small diameter may be modified by pressing the corresponding button Before leaving the dialog the program asks whether it may change the manhole height of the current manhole to a value calculated based on the individual assembly The user will inspect the composition of automatically assembled drop manholes checks and adjusts them He will carry out a comprehensive check of the all manholes inspection chambers He will inspect th
8. mouse in the left hand panel by drag and drop function Then the program asks for a new identification and sequence of the manhole If no manhole was inserted the dialog editing fields are inaccessible Submitting proceeds by submitting of the outlet elevation internal pipe bottom of base element and ground elevation terrain and the manhole terrain ground super elevation when relevant The elevations may be relative negative measured from terrain It is also possible to submit the elevation differences only and the program will calculate the ground level automatically Simultaneously with submitting the program calculates height of the manhole sum of the used elements heights ideal height of a manhole difference of elevations submitted plus the ground super elevation when relevant If the editing is correct a manhole schematic sketch appears also after each modification At an incorrect editing the schematic sketch disappears at the same time an error message appears in the status line of the editing window e g manhole is too high After editing of level conditions the user selects the piping material Based on the selected material the list of existing outlet DN is updated The program offers the existing combinations only Then the user selects the type of base element The program offers all manufacturer s options for the combination of DN and material There are two ways of selection of the base element type selection in
9. the Type of the base element dialog or by ticking of particular connections together with settings of corresponding connection angles The program checks the input data again and it offers the manufactured aS PON WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual base element types only In case the required combination of piping material DN and angle correspond to any manufactured type a schematic sketch of base element appears If such combination do not exist the schematic sketch is crossed out with red lines Once the base element type is edited correctly the user selects a manhole cover in the Cover Selection dialog opened by pressing of relevant button The manhole inspection chamber may be left without any cover then it is necessary to tick Without cover option otherwise the program reports an error Wrong cover The program enables editing of up to three drop connections into one drop manhole After ticking the Drop manhole box with relevant connection the Entry and correction of drop manhole dialog window is called by pressing of Drop manhole button In the dialog the drop manhole DN and the piping bottom height from the outlet bottom of base element are determined The program checks whether the drop manhole does not mouth into a base element or into a joint of two shaft elements The program enables editing of up to three in situ connections through the
10. 0 mm for shafts of DN 600 The lowest shaft of DN 1000 is 125 mm high at WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual 6 Description of menus buttons and dialog windows commands f Plastic sewer manholes and inspection chambers Data1 manhole inspection chamber data 52 ee 5 8 x Fie Edt Tools view Help l amp x mE Deh ES Wavin Ekoplastik s 1 0 7 VA a Gl Ea Plastic sewer manholes and inspectio Seq Identif Base elem elev Ground elev Difference Height Optimal height 4 00 E a ie 1 52 0 00 4 00 4 00 4 00 m Type Inspection chambers DN 315 7 g v j Change height 2 Manhole super elevation over the ground en a0 zo Vehicular and pedestrian roads h 0 Shaft height 3740 mm C An open ground A 15 h 0 00 Manhole inspection chamber bedding sand bedding l Base element DN no 1 Order code Without cover Order code IF1 13700 C iFa 0100 Laf concrete cover 7t 315 Cover bedding Pipe material and pipe type corcide cane PvE smooth 7 Without connect _ Finish of cover surroundings Main connection Angle pf180 o Le eee eee In situ fittings Identification of the element Number Right connection Angle v dh mm DN mm base elem 315 110 type straight 1 I Drop manhole socke
11. 160 to DN 400 Sewer manhole Manhole DN 1000 consists of the base element to which the particular sewer pipes are connected via corresponding gaskets the shaft the eccentric cone transition piece or reducer slab and the manhole cover lit Inspection chamber Inspection chamber DN 315 425 600 consists of the base element the shaft pipe and the cover Shaft elements Are the plastic rings cylinders of construction height 875 750 625 500 375 250 or 125 which forms the shaft Inner diameter of the manhole is 1000 mm Shaft Corrugated pipe DN 315 425 or 600 forms shaft Eccentric cone transition piece forms a transition between the manhole of inner diameter of 1000 and the cover Reducer slab forms a transition between the manhole of inner diameter of 1000 and the cover It is used in cases where a small construction height of a manhole is required It comprises a structural reinforcement now Ea WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual Cover is composed of two parts frame and lid It forms a top termination of each manhole it enables entrance at inspections The covers are supplied acc to required class of bearing capacity road field and garden ones The cover is seated directly onto the shaft shaft pipe or the telescopic adapter or bearing concrete ring cone The bearing ring cone enables to rectify the required elevation of a cover precisely
12. Release Hydroprojekt CZ a s WINPLAN sofware package for designing and drawing of water supply and wastewater systems HYDROPROJEKT Plastic Sewer Manholes and Inspection chambers WINPLAN software package for designing and drawing of water supply and wastewater systems User s manual of Plastic Sewer Manholes and Inspection Chambers 2005 v 2 0 1995 2005 Hydroprojekt CZ a s T borsk 31 140 16 Praha 4 Phone 420 261 102 497 Fax 420 261 215 186 Internet http WWW HYDROPROJEKT CZ WINPLAN E mail winplan hydroprojekt cz Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual Contents SSF Si AOU esse ea E E REE E N A RE E cnet AAE EN nn nee casrecudeaete 1 PSUC Se WEN IANO OS e E E E 1 and Inspection Chambers 2005 v 2 0 ccccsssscccccseseececceeeeeeeeceeeeeceecaeaeceeseeaeceeeseueeeesaeaeeeeesaaeceessaaaeeeessaeeeessaaagss 1 1 FOON e E E E E E A E E E A A E S 4 2 Requirements for hardware and software installation cccccccccsseeeeeseeeeeeeeeeecseseeeseeeeeeaeeeeseaeeeeeeeeeesaneeesaees 6 3 initial description of the program cccccccseececceeseecceeecceseeccauseeceueeesseeeeseeeessueeessuseeesaueeessugeeessueeesseneeessgees 6 4 Inputs and outputs of the PFOQFAM cccccccceeeeceeceeeeeececaeeeeeeeseeeeeeeeeeeeeceeeeseeeeeesaeaeeeeessaueeeeeseaeeeessaaeeeeeesaageeees 8 WI Wire POGAI koras eae eee ete ae nee tga sence aE S POETE Ep aa Eiin 9 5
13. alog for selection of schedules and tables for printing mf WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual By ticking in relevant boxes of dialog window it is possible to select which of the pages will be printed or browsed Model drawings and size tables may be browsed and printed always Other if the program does not detect any error in data only The outputs appear on the screen in the same format in which they will be printed It is possible to print any page both independently and all together from the browsing dialog Preview and printing of the order The order of the manhole inspection chamber elements incl covers appears on the screen in the same format in which it will be printed It is possible to print any page both independently and all together from the browsing dialog Send by E mail f It enables to send the current data as an attachment of a message After selection of this command the window for writing of a message with attached file of current data appears Exit A It terminates the program run in a legal way with an inquiry concerning saving of the modifications carried out in the data file 6 2 Edit Menu ltems of the Edit menu serve for recalling of particular dialog windows in which it is possible to submit the data of a current manhole or information on the designer or they enable a check of the submitted data Edit Tools View Help Unda Chr
14. ata file WITHOUT NAME SPL The user is informed on the necessity to save changes of the current file data al La It will clear down the data of the current data file the user is informed on the necessity to save changes of the data With help of a standard dialog window a selection of the required data file is enabled zk Lay The current data file is closed and removed from the left hand panel the user is informed on the necessity to save changes of the data Page 13 WINP LAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual Save Save as Import into the new file HYDROPROJEKT It saves the current data file to disc If the command is selected with a new data file the Save under name command is switched automatically lt saves to disc the current data file under the user name with help of a standard dialog window This command is used at first saving of a file or at creation of mutations of the existing files The program enables importing of data from the LONGITUDINAL PROFILE OF SEWER program of the WINPLAN system The new file containing loaded data is created The program will load the selected SEW or SXML data file with help of a dialog The program will report the amount of manholes loaded In further dialog it will list the manholes inspection chambers those that must be adjusted or deleted are marked with an asterisk It is always necessary
15. bly will be sequenced from the lowest or from the highest one Data files will be opened with new program start Further the program language and printouts language will be set here Page 26 WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual 6 4 View Menu view b Help ma Cascade BB Tile windows horizontally E Tile windows vertically m Left panel m Tables e Edit control panel Control panel 1 Dataz manholesinspection chamber data 52 Fig 20 View menu Cascade T After selection the opened dialog windows will be arranged in a form of a cascade The windows horizontally a After selection the opened dialog windows will be arranged in a form of horizontal windows The windows vertically After selection the opened dialog windows will be arranged in a form of vertical windows Left panel O The command enables to switch ON OFF the display of the opened data files with manholes in left hand side of the working area Tables E The command enables to switch ON OFF the display of tables in bottom part of the working area Arrange toolbars 4 The command enables to arrange the quick access button bars in upper part of the working area Toolbars The command enables to switch ON OFF the display of particular button bars aS _ WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual Sta
16. d then move by pointing to the desired working editing window by the mouse at WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual 4 Inputs and outputs of the program Program inputs Besides the standard opening of the SPL file the program enables loading of both the SEW file of the SEWER LONGITUDINAL PROFILE release 4 0 and SXML file of the SEWER LONGITUDINAL PROFILE release 5 0 programs Program outputs A Output to data file SPL DXF B Output to printer HYDROPROJEKT data file of the PLASTIC SEWER MANHOLES AND INSPECTION CHAMBERS program maximum number of manholes in one file is not limited drawing data file of the CAD programs a package type file which cannot be opened directly see export to DXF in A4 landscape format print of the model drawings print of the manholes and inspection chambers shaft elements table print of the base elements table print of manholes assemblies print of drop manholes table and in situ print of covers table in A4 portrait format order of shaft elements incl base elements covers Page 8 WI NP LA N Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual 5 Working with the program Working with the PLASTIC SEWER MANHOLES AND INSPECTION CHAMBERS program at design of manholes is described in this chapter Working in particular dia
17. d sewer piping through which wastewater flows into the manhole inspection chamber mouthed into the base element Selection of material and DN are similar as with the outlet With respect to outlet the axe angle connection may be 90 to 270 clockwise A linear manhole inspection chamber has the primary inlet angle of 180 Counter direction of the connection junctions is inadmissible When the piping connection are designed it is necessary to focus on that no collision among the particular piping occurs and the base element manufacturing be feasible The 3rd connection is further third sewer piping through which a wastewater flows into the manhole connection pipe is mouthed into the base element Other applies similarly as for the 2nd connection aS _ WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual Delta h is the level difference between the outlet pipe internal bottom and connection bottom grade lines it is provided in mm For plastic manholes and inspection chambers it is insignificant or equals to 0 mm Benching is a step on surface inside the base element around the wastewater channel Channel is a trough in the base element through which the wastewater is led from inlets to outlet Identification of the manhole is a name of manhole which may be submitted arbitrarily acc to need of the particular sewer design documentation Reduction element solution in the a
18. e drawings and tables print the drawings tables orders The procedure of individual assembly The program enables as well using of other options of data editing apart from the traditional way 1 The individual assembly of manhole inspection chamber DN 1000 This option is used for editing of automatically assembled manholes inspection chambers If the arrow is pointing at the particular element the element can be replaced or deleted If the arrow is pointing to the gap between two elements the another chosen element can be added now hei WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual 2 Placing and ordering of an atypical base element production for manholes DN 600 and DN 1000 using the corresponding option in the dialog together with submitting of such connection angles which do not comply with the standard production catalogue 3 Individual specification of the manhole shaft height When the option Change height of the shaft is ticked the shaft height may be modified by switching the arrows in dialog However the height must be the multiple of lengths given by possible cutting interval of pipe The interrelation between the manhole inspection chamber actual height and the ideal height could be influenced with this approach 5 1 Limiting conditions The program enables designing of plastic sewer manholes and inspection chambers with internal diameter of DN 315 and DN 425 f
19. e elements Fig 25 table of base elements 3 Table of drop manholes and in situ e gt E E a en inspect ch gound pase p manh base base edge base base edge base base situ aessa base situ aessa base ir TE 15800 15800 15200 800 110 110 O D ESD a O SAA DO SE NE DOS OEN DON IONA DNG SED EEE AE ASD I O OE OE GA aT o CC o o O T S T TO T S T S S T S S S S OE E O O O O O S O S S S S S S S S S S S S S S O Table of manholes inspection chambers Table of base elements Table of drop manholes and in situ Table of atypical base elements Fig 26 table of drop manholes and in situ 4 Table of covers xi ch oad of the cover of the cover cover surroundings of he Sover number cast iron cover B125 into the telescopic adapter structure of vehicular road RF71000 ana cast iron cover C250 on top of the concrete ring RF72000 Table of manholes inspection chambers Table of base elements Table of drop manholes and in situ Table of covers Table of atypical base elements Fig 27 table of covers 5 Table of atypical base elements xi e gt bN ad EH e e eT inspect ch angle angle angle base Table of manholes inspection chambers Table of base elements Table of drop manholes and in situ Table of atypical base elements Fig 28 table of atypical base elements mm _ WINPLAN
20. element E Drop manhole socket angle is 7 5 a Tri situs fittings Right connection Angle dh mm BM mm base elem TEGRA W 1000 200 30 Number EEN sealat 1000 O o s Eo shaft elem TEGRA 1000 L625 1 a Li Orop mankole socket angle is 7 5 F Left connection Angle l Drop manhole socket angle is 7 5 O O 1 O 4 1 concrete ring 600 1 High profile manhole Structural engineering assessment needed Manhole inspection chamber data is correct Fig 29 dialog for editing of the manhole inspection chambers data In the submission dialog the user completes the data of current manhole inspection chamber If there is no manhole in the file all editing fields are non active and it is necessary to insert the manhole inspection chamber by the New manhole inspection chamber button The program processes the data immediately and always tries to design a manhole inspection chamber according to them If the data are correct and complete in the dialog a schematic drawing of the assembled manhole inspection chamber and the list of used elements appear In opposite case an error message appears in the status line of the dialog The changes are also shown immediately in the tables ae a WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual HYDROPROJEKT It is possible to recall further dialogs from this dialog Selection of base e
21. eplace the shaft elements always after switching to individual assembly dialog or to change H The automatic assembly does not monitor correctness of the connection pipe junction into the shaft element Manholes inspection chambers overall check up Le Main connection drop manhole leads into the base element Manholefinspection chamber no 1 52 Change input Fig 18 dialog for manholes overall check up Information on shortcomings and errors is provided here At wrongly insufficiently completed data the program will not print relevant outputs tables The correction of data is necessary or defect manholes must be deleted The errors may be represented by the manhole data drop manhole or in case no cover is selected If you want to design a manhole without cover it must be identified as such Renumbering of manholes 12 The program will re number the submitted manholes starting from 1 ate e WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 Options HYDROPROJEKT Assembling of shatt elements Program language English bi Changes will occur the nest time wou restart the program Language of printouts English Data files at the left hand panel open data files with program restart conci Fig 19 dialog for setting of the program options The user will determine in the dialog whether User s manual Shaft elements at automatic assem
22. ese of the company distributing the program The overall structure of the WINPLAN software system is obvious best from the following block diagram The rectangles represent the particular modules of the system programs the arrows then represent their links at cooperation and sharing the data aS ENP WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual HYDRONet MAPPING SCHEMATIC LONGITUDINAL PROFILE ODULA DIGITAL TERRAIN MODEL ROUTE SEWER SYSTEM LONGITUDINAL PROFILE WATER SUPPLY YSTEM LONGITUDINAL SEWER MANHOLES AND INSPECTION CHAMBERS WATER SYSTEM ASSEMBLY SCHEME LAYOUT All information on software sale and user support are provided by the Hydroinformatics Team of Hydroprojekt CZ a s Taborska 31 140 16 Praha 4 The basic data on programs may be found on the following web site www hydroprojekt cz Winplan To send inquiries and requests for information the winplan hydroprojekt cz e mail address may be used Telephonic information may be obtained at phone number 420 261 102 497 or facsimile number 420 261 215 186 The software system elaborators team would be grateful for any of your suggestions inquiries and comments which might help to the system improvement or extension We wish you a pleasant and efficient work with our tools at WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual
23. estinspection chambers Options Fig 12 Tools menu mf WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual Base element selection Base element type selection DN 1000 fexibl 4 Ll Fig 13 Dialog of the base element type selection The selection is done by marking of corresponding base element type The program offers the manufactured types only Dialog is recalled from the Editing dialog by Lal button Cover selection Cover selection for manholes DN 1000 x cast iron cover 415 on top of the concrete ring 0 cast iron cower B125 on top of the concrete ring 0 cast iron cover C250 on top of the concrete ring a0 castion gid B125 ontop of the concrete ing 80 cast iron gid C250 on top of the concrete ing 80 cast iron grid D400 CBE Canos Fig 14 dialog of the covers selection mS _ WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual Individual assembly HYDROPROJEKT Individual manhole inspection chamber assembly Manholeinspection chamber assembly Elements Highlighting of relevant line carries out selection of the cover Dialog is recalled from the Editing dialog by button x Shaft elements Cone H 125 mm i cone DM 1000 H 250 mm H 375 mm H 500 mm H 625 mm H 50 mm H 875 mm H 1000 mm Floor remforced concrete slab C floor s
24. for all manholes to check and adjust the piping material to a material which is in the offer it corresponds to the catalogue of manufacturer selected before the data importing It is necessary to correct all the reported errors to enable the program work with the data The most frequently reported error is a too low manhole inspection chamber or wrongly determined axe angle of connection Too big delta h is not monitored during the data loading It must be corrected consequently or the particular manhole with big delta h must be designed as a drop manhole If in the longitudinal profile no different elevations of the outlet base element and the 1st connection drop manhole are submitted the delta h is determined automatically as a sum of the manhole inspection chamber radii multiplied by longitudinal gradient in the sections upstream and downstream the manhole inspection chamber This dialog is not part in so called free version which is distributed free of charge With the free version you have to submit all the necessary data from the keyboard or with help of a mouse Page 14 WINP LAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual Import into the active file The program enables importing of data from the SEWER LONGITUDINAL PROFILE program of the WINPLAN system In this case the relevant loaded data are added next the currently edited manhole of the active file The program wil
25. hich provides the basic visual idea on structure of the designed manholes and their dimensions Table of manholes inspection chambers is an enclosure of a sewer design documents which comprehensively provides the basic information on the designed manholes inspection chambers Table of drop manholes and in situ is an enclosure of a sewer design documentation which comprehensively provides the basic information on the designed drop manholes and in situ Table of base elements aS P WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual is an enclosure of a sewer design documentation which comprehensively provides the basic information on base element for the designed manholes inspection chambers Table of manhole assemblies is an enclosure comprising the schematic sketches of all manholes and a list of elements from which a manhole is composed Table of covers is an enclosure of a sewer design which comprehensively provides the basic information on the covers for the designed manhole inspection chamber Order of manhole inspection chambers elements is a list of all manhole inspection chambers components incl base elements and covers in a form of an order complemented with data on the client The enclosure of this order are also tables of manholes inspection chambers drop manholes and in situ base elements as well as covers aS _ WINPLAN
26. l 2 Alt Backspace Enter manholefinspection chamber Cancel manholefinspection chamber Next manholefinspection chamber Previous manholefinspection chamber Lg Project and designer data eal Order product list Customer order data Fig 6 Edit menu at WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual Undo Redo K The command will delete recent modifications made in current manhole inspection chambers data step backward a The command will do again the modification recently cancelled by Undo command in current manhole data step forward Insert the new manhole inspection chamber rm Delete the manhole Next manhole Previous manhole HYDROPROJEKT New manhole inspection chambet x Manholeinspection chamber number and identification EM Cancel Fig 7 dialog for insertion of a new manhole The command will insert the new manhole inspection chamber into the data file In the dialog we submit the sequence and identification I Question x Do you want to delete the manholeinepection chamber no 17 Yes Ho Cancel Fig 8 dialog for deletion of the manhole The command will delete current manhole inspection chamber from the data file Faa The commands enable to list in the sequence of manholes in the opened file and to set the selected manhole as the current one Page 18 WINP LAN Pla
27. l load the selected SEW or SXML data file with help of a dialog The program will report the amount of manholes inspection chambers loaded In further dialog it will list the manholes those that must be adjusted or deleted are marked with an asterisk It is always necessary for all manholes to check and adjust the piping material to a material which is in the offer it corresponds to the catalogue of manufacturer selected before the data importing It is necessary to correct all the reported errors to enable the program work with the data The most frequently reported error is a too low manhole inspection chamber or wrongly determined axe angle of connection Too big delta h is not monitored during the data loading It must be corrected consequently or the particular manhole with big delta h must be designed as a drop manhole If in the longitudinal profile no different elevations of the outlet base element and the 1st connection drop manhole are submitted the delta h is determined automatically as a sum of the manhole radii multiplied by longitudinal gradient in the sections upstream and downstream the manhole This dialog is not part in so called free version which is distributed free of charge With the free version you have to submit all the necessary data from the keyboard or with help of a mouse Export of tables into MS Excel format Tables selection for export to Excel E XI Files placement C Program Files Wi
28. lab Manholeinspection chamber data Fart base elem TEGRA W 1000 200 30 base element elevation m a 5 152 00 ground elevation m a SL 158 00 elevation of the upper manhol 156 00 total height of elements mm 00i Fig 15 dialog for individual assembly of a manhole inspection chamber The tool is accessible after ticking the Individual assembly box in the manhole submitting dialog only In the dialog which appears it is possible to assemble the current manhole from all available elements of the manufacturer The logical link among elements used is not checked After pressing of the OK button it is checked only whether the elements link to each other if the upper width of the element is similar with the width of the next element below In case the set is not all right the user must adjust it It is possible to change height of the manhole by individual assembly design The user is informed on the change of height and if he she does not agree he she may adjust the set It is possible to recall the dialog directly from the Editing dialog by button located to the right from the individual assembly tick box Page 22 WI NP LA N Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual HYDROPROJEKT In the beginning of using the Individual Assembly dialog the automatic design of the manhole inspection chamber will be displayed In the dialog it is possible to change the assemb
29. lement type Selection of cover Individual assembly only for DN 1000 there is another tool Change height of the shaft for other types of manholes inspection chambers Editing of drop manhole and Overall check up of manholes described in the preceding chapters The submission dialog is described in detail in Chapter 5 Working with the program Page 33 WI NP LA N Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual 7 Description and general rules of sewer manholes assembly Range of application Sewer manholes inspection chambers can be designed for sewers Sewer mains of following pipe material smooth PVC ULTRA RIB 1 ULTRA RIB 2 ULTRA RIB 1 DIN a ULTRA RIB 2 DIN with profiles range from DN 110 to DN 450 The type of manhole designed can be inspection chamber terminal manhole junction manhole bend manhole and with limited range also drop manhole Depth of manholes is up to 5m inspection chambers up to 6 m design of deeper manholes must be complemented with a structural engineering assessment of bearing capacity The system enables to mouth the outlet the 1st 2nd and 3rd connections to base element The program enables designing of plastic sewer manholes inspection chambers of internal diameter of shaft of DN 315 and DN 425 for connections range from DN 110 to DN 450 and sewer plastic manholes inspection chambers of internal shaft diameter DN 600 and DN 1000 for connections range from DN
30. log windows is a topic of following chapters User of the full version will select the manufacturer and executes downloading importing of longitudinal profile data and adjustment of data errors consequently File Menu or he she may submit the particular manholes data in the editing dialog User of a free version must submit all the manholes in the editing dialog The submitting of manholes itself proceeds as follows The user creates a new file by pressing a button or selecting New command in File menu A new editing window appears Then in the quick access keys bar a manufacturer is selected This data is common for all manholes of the given file Then a new manhole may be inserted and its data submitted The New manhole button in the editing dialog inserts the manhole Program asks for sequence and identification of the manhole Each manhole must have an unambiguous sequence number The sequence number determines sequence of the manhole ina file Identification of the manholes is arbitrary and it may be repeated within the framework of one file Identification must not be empty The program checks whether a manhole with identical serial number exists If so the program offers insertion of a manhole with a shift of the following manholes numbering It is possible to change the identification anytime later After insertion of the manhole the sequence may be modified only by the manhole shifting to other position with help of a
31. ly of the manhole with help of buttons acc to individual idea by re writing editing from the catalogue and also by erasing of particular elements of the automatically created manhole with exception of the base element Arrow in the manhole assembly always indicates the upper part of the element The Move up and Move down buttons serve for moving of selected element up or down The element is selected when the sign 4 points towards it The a and v buttons serve for shift of the cursor indicating to elements upwards and downwards The Replace button replaces the active element indicated by 4 cursor with the element selected in the right hand part of the dialog catalogue The Delete button will erase the element indicated by 4 cursor The Insert button will insert the element selected in the right hand part of the dialog The OK button will confirm changes and close the dialog the Cancel button will revoke the changes and close the dialog Page 23 WI NP LA N Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual Entry and correction of drop manhole a HYDROPROJEKT E Individual L set DM 1 Pevere te H SEQUENCE ON 200 i The drop manhole by main conn DN1 110 H mm 0 Phe dop manhole by ight canm DNi 170 z H mm 0 M he dopmeanhae byler cann DN1 110 H mm 0 Cancel Fig 16 dialog fo
32. nPlanSachty2005 Table of manholesinspection chambers Table of manholeinspection chambers base elements Table of covers JOrder of manholeinspection chamber elements Select all Cancel all Fig 3 HYDROPROJEKT dialog for export of manhole inspection chamber into Excel Page 15 WINP LAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual The command enables export of selected tables into MS Excel format Printer setup Nastaveni tisku aaa Fig 4 dialog for printer setup Dialog enables selection of a printer and setting of printing options orientation of paper etc The program automatically sets the orientation of print for printing of tables and for printing of orders We do not recommend changing this setting Preview and print of tables E Print settings and preview of tables Sewer inspecton chamber 315 with plastic cover with grab handles Sewer inspecton chamber 315 with concrete cower Sewer inspection chamber 375 with cast iron grid D400 Sewer inspecton chamber 315 with cast ron cover St and telescopic pipe Sewer inspecton chamber 315 with cast ron cover perforated cast iron cover Sewer inspecton chamber 315 with cast ron cover with frame 10t and concre Sewer inspecton chamber 315 with plastic grid cupola and telescopic pipe Sewer inspecton chamber 315 with plastic cover and with frame m Lf Fig 5 di
33. or piping ranges from DN 110 to DN 450 and sewer manholes with internal diameter of DN 600 and DN 1000 for piping ranges from DN 160 to DN 400 Maximum depth of a manhole without professional structural engineering assessment for DN 315 425 and 600 corresponds to maximum shaft length of 6 m or similarly 5 m for DN 1000 The program enables to design even deeper manholes up to 15 m The minimum manhole heights corresponds to the minimum structural height of particular manhole inspection chamber type Maximum amount of the piping mouthed into a manhole base element is one outlet the 1st connection main and secondary connections Nos 2 and 3 Minimum amount of the piping mouthed into a manhole base element is outlet only at a terminal manhole inspection chamber option Delta H for plastic base elements is insignificant or 0 mm Axe angles of the connections against the outlet acc to manhole clock must be within 90 to 270 range The counter direction junction is not admissible Arrangement of all connections with respect to selected profiles of piping must be such to prevent overlapping of the individual piping including relevant inserts and to ensure sufficient gaps among inserts enabling the manhole base element manufacturing Program checks the spatial arrangement of connections acc to selected material The shaft heights are limited with the cutting interval of shaft pipe 55 mm for shafts of DN 315 75 mm for shafts of DN 425 10
34. r entry and correction of a drop manhole data The item is only available in case of ticking at least one drop manhole box next to connections in the manhole submitting dialog In the dialog which will appear it is possible to submit DN of a drop manhole connection and height measured from the outlet bottom The program checks whether the drop manhole connection is not in the base element or in two elements joint The dialog may be recalled directly from the Editing dialog by a button gi If the delta h determined or counted from the longitudinal profile is bigger than difference of the base element height and a sum of outlet DN and the minimum mouthing of insert below the base element edge 150 mm it is necessary to mark this manhole in the editing dialog in relevant connection as a drop manhole tick the drop manhole box and to solve it as a drop manhole Then the delta h becomes the H height of the drop manhole and the program does not report a wrong data of big delta h Here DN of connection is DN1 DN2 and dh is selected The automatically assembled drop manhole will be displayed Page 24 WI NP LA N Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual The manhole will be displayed even when the basic data are submitted wrongly it is necessary to carry out a check from the editing dialog By the Check button it is necessary to check correctness of the outlet junction to shafts and or to r
35. so the quick access buttons Among the buttons there is a roll down menu for selection of a manufacturer common for the whole file The editing dialog with data of the currently designed manhole inspection chamber and its schematic drawing Is in the centre of working area If there is no manhole inspection chamber in the file all the editing fields are inactive The left hand panel displays the open data files with all inserted manholes inspection chambers The particular print outputs tables are scheduled and displayed in a table in bottom part of the screen a _ WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual 6 1 File Menu ltems of the File menu serve for working with the manholes data files for setting of an empty data file for insertion of new data for loading importing of longitudinal profile data for printing of results for selection of a current printer for print preview and for the program termination New Open Close HYDROPROJEKT Tools View Help Edit 4 New Ctrl h t Open Ctrl C Ce Close Ey save Ctrl 5 ll Save Os import Ito there L j b iis Into the active File Printer Settings 29 Preview and print of tables Preview and print of the order f Send by E mail 1 C Program Filesi Datal spl nA End Fig 2 File menu L It will clear down the data of the current data file and assign a name to a new d
36. spection Chambers 2005 Release 2 0 User s manual In the panel it is possible to copy by the mouse any manhole to any file with help of the drag and drop function We press the left hand button of the mouse on the manhole inspection chambers name and with the button kept depressed we shift the manhole to a new position After releasing of the button the program will enable us to submit a new name and sequence of manhole inspection chambers In the dialog we may also select whether we want to shift the manhole inspection chambers erase it in the original file or to copy it 6 8 Table 1 Table of manholes inspection chambers x t Manholes elevation m a en a ea shaft elements pc ei ch ground top manh inspec ch i IA 875 750 625 500 375 250 slab i 00 144 89 La 00 489 rmadh 0 0m base elem TEGRA 600 160 straight 4500 a 00 158 00 152 00 600 roadh 0 0m base elem TEGRA 10007200 30 200 OOO ee ee ee Table of base elements Table of drop manholes and in situ Table of atypical base elements Fig 24 table of manholes inspection chambers Lies ch ine gle angle angle base of conn elem ia cae 600 160 straig fa PYC ah 140 00 mn sand bedding 253 __t tere elem TEGRAY 1000 200 30 200 PVC smooth 152 00 150 sand bedding Table of manholes inspection chambers Table of base elements Table of drop manholes and in situ Table of atypical bas
37. stic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual Project and designer data E Project and designer data a x Froject Facility Ae Designer Fig 9 dialog for inserting of project and designer data Common data for identification card of drawings and tables Order product list m The product list for order i 2 x Delete this line The product list was not modified by user Note Index RF 11000 MFg2021 MF110000 sealant 1000 o y OB RPO3O00 MF62500 MFIO0000 shaft elem TEGRA 1000 L 10000 oo y A F261000 AF900000 telescopic adapter E00 o o OT MFIO6400 adaptative cone TEGAA 1000 RF6O000 Supplier wavin Ekoplastik s r o depo Jihlava All used products Preview and print of the order Customer data co Fig 10 dialog containing a product list for order A dialog will appear in which all the products and elements used in the current file are listed The user may modify the list erase lines change amount of pieces ate a WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual Customer order data Customer data Fig 11 dialog containing customer data for order Common data for order will be completed 6 3 Tools Menu Base element selection Cover selection Individual assembly Entry of drop manhole Manholes overall check up Renumbering of manhol
38. t angle is 1 5 0 corrugated pipe 315 l 3740 mm 1 O concrete cone 315 1 Left connection Angle z LO sealant 1 I Drop manhole socket angle is 1 5 concrete cover 7t 315 1 Manhole inspection chamber data is correct 1 Table of manholes inspection chambers xi e gt Manholes elevation m a SL placement type DN shaft elements pc inspect ch ground top base m manh inspec ch base mm 750 625 500 375 250 52 4 00 4 00 0 00 400 roadh 0 0m base elem 315 110 type straight 110 400 400 O00 400 toadh 0 0m base elem TEGRA 600 160 straigh 160 Le a Table of manholes inspection chambers Table of base elements Table of drop manholes and in situ Table of covers Table of atypical base elements Fig 1 user s interface of the Plastic Sewer Manholes and inspection chambers 2005 program Controlling of the program proceeds in the basic user s interface of the application i e in the MANHOLES INSPECTIONS CHAMBERS DATA window The current SPL file name appears on the left hand side of the window name in the main title In the main menu there are standard commands for working with data File menu commands for editing of data Edit menu and Tools menu commands for working with windows View menu and commands for calling of help Help menu A majority of commands has al
39. tus line The command enables to switch ON OFF the display of the status line aS WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual 6 5 Help Menu A A A A A A Program operation Program operation About the program Plastic manholes and inspection chambers Catalogue of plastic inspection chambers DN 315 and DN 425 Catalogue of plastic inspection chambers ON 600 and manholes OM 1000 Plastic manholessinspection chamber assembly Inspection chambers wAvI MOR Manholes Tegra 1000 flexible connections Flexible IN SITU connection Fig 21 Help menu ltems of the Help menu enable recalling of the program help or sewer manholes help or recalling of the application information Help in the program is solved in a standard way typical for MS Windows Current help appears also on the bar located in the left hand bottom corner of the screen The manufacturers catalogues in pdf format Adobe Acrobat 6 0 can be accessed from this dialog D The command comprises help of the program operation About the program Plastic Sewer Manholes and Inspection Chambers HYDROPROJEKT i The dialog window comprises information on the program version and its author In the information on the application the versions of all important files and or information on hardlock key for the purchased version By the mouse click in left hand part of the dialog we can get directl
40. undantly used program for concrete manholes PRECAST SEWER MANHOLES Besides current production catalogues of the manufacturer Wavin this new version offers anew also a language version of the program Simultaneously with this program inclusion of next manufacturer of plastic manholes is prepared and the PLASTIC SEWER GULLIES program is being developed as well All these programs continue to be the components of the WINPLAN system software package for designing and drawing of water supply and wastewater systems particularly pipe lines on PCs in Microsoft Windows The particular programs of this package may be used independently they have autonomous inputs and outputs If you are the owner of the program free version only which is distributed to designers and project planners as a service of companies like Wavin and Bocr under preparation within the promotion of their products you do not need the hardware key hardlock for the program running However you do not have the possibility to load automatically the data from a longitudinal profile of sewer processed in the WINPLAN system This function is a feature of the full version only which is sold and distributed by Hydroprojekt CZ With the free version you have to enter all the necessary data via keyboard or with help of a mouse Concerning the program outputs all the versions are equivalent In the free versions of course the products of one company only are listed th
41. utomatic design is solved preferably with help of the eccentric cone only if the manhole structural height is too low a cover slab is used In the program it is possible to switch to design with a cover slab even with the high manholes Footstep For manholes of DN 1000 the footsteps are mounted into shaft elements and eccentric cone during the manufacturing in factory The step height is 250 mm Automatic design means that the program will design structure of the manhole based on inserted elevations of the ground and outlet bottom Further auxiliary data are the outlet DN location of manhole height of fill and type of cover The manholes elements are design in such way to achieve the required cover elevation as precisely as possible As a rule at location in a free ground the cover grade line is above the submitted level ground level fill height as it results from the individual components structure Individual design enables editing of the automatically assembled structure of a manhole DN 1000 from individual elements above the base elements Bedding of a manhole The concrete or sand sub layer are the options for the manhole bedding Finish of manhole cover surroundings no ma WINPLAN Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual depends on location of a manhole In a free ground it is possible to design a protection of the cover by a granite pavement into concrete by a precast ring or
42. y to www hydroprojekt cz winplan page with the latest information on the system Page 29 WI NP LA N Plastic Sewer Manholes and Inspection Chambers 2005 Release 2 0 User s manual 6 6 Manufacturer of manholes and inspection chambers wavin Ekoplastik s r o Fig 22 selection of the manholes inspection chambers manufacturer Here in the beginning of work the manufacturer of manholes inspection chambers valid for the whole data file is to be selected In one data file it is not possible to design a combination of various manufacturers The selected manufacturer applies always to all manholes inspection chambers in a file The so called free version has one manufacturer only provided in the selection 6 7 Left hand side list of manholes inspection chambers files HYDROPROJEKT d Plastic sewer manholes and inspection chambers Data2 Fig 23 list of opened files The left hand side panel displays the opened data files with all inserted manholes inspection chambers It enables a quick access to particular manhole either by clicking of the left mouse button or via contextual menu after clicking of the right mouse button The contextual menu enables a quick deleting and correction of the manholes inspection chambers The contextual menu with the data name item enables opening of the new data saving or closing of these data or their sending by e mail Page 30 WI NP LA N Plastic Sewer Manholes and In
Download Pdf Manuals
Related Search
Related Contents
View Online Samsung Духова шафа Dual Cook Керівництво користувача Manual de instalación - CI Energia Solar ESWindows AiSEGの機能 を使ってみましょう AiSEGの機能 を使ってみましょう Model 850 Actuator Installation Instructions and Service Manual TAFCO WINDOWS NU2-117V-I Instructions / Assembly Sony DSC-RX10 Instruction Manual カタログ - チノー Copyright © All rights reserved.
Failed to retrieve file