Home

ACM-4201 - SOTRONIK

image

Contents

1. ACM 4201 Megapixel IP Cube Camera Hardware User s Manual DC 12V PoE Ver 2010 6 7 D4 ACTI ACM 4201 Hardware User s Manual Table of Contents 0 Precautions 3 1 Introduction 4 Package Contents sansnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnne 4 Features and Benefits cccececsccscececececcccscucucececeececneueaeaeeeceeueueaeereees 5 Safety SUN CUION S roaraa 6 PTV SICA deS pU Oaa E EA 8 BASIC CONNEC CON S rerni 11 Product Specification saree sieseadectpnccanatesaneeet vecanetenawensaeseatebpnantnaes 12 2 Accessing Camera 13 If you have DHCP server router in your network cee 13 If you do NOT have DHCP server router in your network 13 2 VVAYAYAYA rol LU Xe aa ACTI Connecting Vision vA ACM 4201 Hardware User s Manual 0 Precautions Read these instructions You should read all the safety and operating instructions before using this product Heed all warnings You must adhere to all the warnings on the product and in the instruction manual Failure to follow the safety instruction given may directly endanger people cause damage to the system or to other equipment Servicing Do not attempt to service this video device yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel Trademarks All names used in this manual are prob
2. s Ethernet port to Network switch via RJ45 connectors Connect a PC to the Ethernet switch via RJ45 connectors Please refer our PoE Guide for more details on Power over Ethernet related concepts 11 www acti com pq ACTI Connecting Vision ACM 4201 Hardware User s Manual Product Specification esess i itsS ACM 4201 es Micron Progressive Scan CMOS Effective Pixels 1280 H x 1024 V lenanadon Lens 4 2mm F1 8 Viewing Angle 75 Horizontal Sy nc System Internal Motion Detection Yes 3 Windows Electronic shutter 1 5 1 15 000 sec 1 30 1 1 000 sec 60Hz F h M s G 1 25 1 1 000 sec 50Hz 1 120 sec 60Hz Flickerl PE 1 100 sec 50Hz LC es GC Automatic User defined hite Balance AUTO INDOOR1 INDOOR2 OUTDOOR1 OUTDOOR2 HOLD CURRENT MANUAL S N Ratio S N BALA Better than 44 dB O D lt O D r iit gt SXGA 1280 x 1024 HD 720 1280 x 720 Picture Resolution VGA 640 x 480 QVGA 320 x 240 Video QQVGA 160 x 112 Compression SXGA at 8 fos HD720 at 10 fps Image Frame Rate VGA at 30 fps QVGA at 30 fps QQVGA at 30 fps 8kHz Mono PCM Audio Input Sensitivity 36 3dB OdB 1V Pa Built in Microphone S N Ratio more than 58dB Directivity Omni directional Compression 8kHz Mono PCM R Compression Mono TEMS ML Audio Line Output Unbalanced 1 4Vp p 1Vrms 3 5mm Phone Jack Digital Input 1 TTL terminal block Digital
3. It can compress and transmit real time images with outstanding image quality 8 FPS SXGA 1280x1024 through a standard TCP IP network This camera is your best choice to build an intelligent IP surveillance system MPEG 4 MJPEG Dual Codec Compression This device supports two compression formats MPEG 4 and MJPEG It brings superior image quality at 8 frames per second up to a resolution of SXGA 1280 x 1024 pixels and offers up to 10 frames per second in HD720 1280x720 In VGA 640 x 480 QVGA QQVGA the device reaches 30 frames per second Built in Hardware Motion Detection No more external motion sensors are required You may assign up to 3 video motion detection areas By tuning the object size and sensitivity it will reliably detect objects passing though Is view Hardware motion detection also offers better sensitivity and faster response time than software motion detection Powerful Bundled Surveillance Software To extend the capabilities of the IP Box Camera series a powerful surveillance program is included in the package for free Users can easily use an existing PC as a digital video recorder Scheduled recording and manual recording keep every important video recorded in the local hard disk Reliable and accurate motion detection with instant warning enables immediate response in every condition Quick and simple search and playback function lets you easily find the images and video you want Software Development
4. Output 1 TTL terminal block Yes External 1 0 Reset Button Factory Default SSS System Status Ethernet Ethernet 10 100 Base T RJ45 Connector TCP UDP IP HTTP HTTPS DHCP PPPoE RTP RTSP FTIP SMTP DNS DDNS NTP ICMP IGMP ARP UPnP peon po Microsoft Internet Explorer 6 0 or above ACTi SDK 10000 Security Password Protection Configured by the administrator 10 C 50 C 14 F 122 F PoE IEEE 802 3af with Class 3 e DC 12V 2 88W PoE 4 32W 88 mm x 85 mm x 39 mm 3 46 x 3 35 x 1 54 150g 0 33 Ib w o bracket Available only for device versions with enhancements 12 www acti com D4 ACTI ACM 4201 Hardware User s Manual 2 Accessing Camera If you have DHCP server router in your network Many network server routers are able to automatically provide IP addresses through DHCP If you are using such a network just plug in your computer and IP Camera into the network and your IP device will acquire network address by itself Find and access the device with our IP Utility program You may download it at http www acti com product detail Software ACTi Utility Suite If you do NOT have DHCP server router in your network 1 Configure your PC to use the same subnet by changing your PC s IP address to the subnet with prefix 192 168 0 XXX The last number should be anything from 1 to 254 except 100 and other occupied IP addresses Subnet mask should be 255 555 25
5. gt Bonjour a ene Bitrate 3M gt gt IP Address Filtering Video Control Port 6001 gt gt Event Video Streaming Pot 6002 Reset gt gt User Account gt gt System Info 16 www acti com
6. in you will see the video from camera To go to the main menu click the Setup button on the top left gt gt Setup 92 Video Display MPEG4 _ Scale Down F Audio Out amp Volume 84 v 2004 01 01 07 55 23 If you are using a single camera this is enough to access the device 14 www acti com ACTI Connecting Vision vA ACM 4201 Hardware User s Manual If you are using multiple devices you need to change the current device to another unused IP address so that when the next device is connected to the network no two devices use the same IP Please perform the following steps 7 Goto Setup gt WAN Setting 8 Choose Static IP Address 9 Change the IP to 192 168 0 101 or any other unused IPs Do NOT use the PC s IP address or 192 168 0 100 If this is not the first device you add to the network please also avoid other devices IPs Camera 1 gt gt Video Display SOO WAN Setting gt gt Host Setting Dynamic IP Address gt gt WAN Setting C UseHostName ACTI IF Address 192 _ 168 0 101 gt gt Video Setting i l Subnet Mask 255 E255 _ 255 0 gt gt Video Adjustment ISP Gateway 192 _ 168 _ 0 _ 254 gt gt OSD Privacy Mask O PPPoE gt gt Camera Setup User Name gt gt SNMP Setting Password gt gt UPnPp gt gt Bonjour Apply 10 Click Apply 11 Please go to Save Reboot and click Apply Internet Explorer
7. will close after a few seconds This is normal 15 www acti com ACTI Connecting Vision vA ACM 4201 Hardware User s Manual gt gt Video Display URH System Save And Reboot G Click apply to save all settings and rebootthis device gt gt WAN Setting gt gt Date Setting Reset gt gt Video Setting gt gt Video Adjustment gt gt OSD Privacy Mask gt gt Camera Setup gt gt SNMP Setting gt gt UPnPp gt gt Bonjour gt gt IP Address Filtering gt gt Event gt gt User Account gt gt System Info gt gt Firmware gt gt Profile gt gt Factory Default gt gt Save Reboot 12 Wait for 30 seconds and open IE again to connect to the new IP In this example 192 168 0 101 For the second device or more you add into the network please type the correct IP 13 Adjust the video stream by going to Video Setting gt Video Display CoO Version V2 0 Video Setting Un Qeti E gt gt Host Setting CameraName Camera 1 gt gt WAN Setting Streaming Method TCP Only gt gt Date Setting B2 Frame Enable Audio In Disabled gt gt Video Setting Analog Video NTSC gt gt Video Adjustment Resolution 1280x1024 po ee Frame Rate Mode Constant gt gt Camera Setup Frame Rate 8 gt gt SNMP Setting Encoder Type MPEG4 gt gt UPnp Video Bitrate Mode Constant Bit Rate Video Maximum Bitrate UNLIMITED gt
8. 5 0 2 The default IP used by this device is 192 168 0 100 Please make sure your PC is NOT using this address and that no two equipments use the same IP address in the network 3 Change your IP address by going to Control Panel gt Manage Network Connections gt Right click on the connection to change gt Option gt TCP IP IPv4 Properties ajx General You can get IP settings assigned automatically f your network supports thes capability Othemise you need to ask your network administrator for Please set the settings as below the appropriate IP settings IP address 192 168 O xxx Subnet mask 255 255 255 0 C Obtain an IP addeess automatically Use the following IP address IP address Subnet mask Default gateway NOTE xxx should be a number from 1 to 254 except 100 which is r Use the following DNS server addresses Prefered ONS server Afermate ONS server used by the IP device Please also make sure that no two equipments use the same IP address in the same network www acti com ACTI Connecting Vision vA ACM 4201 Hardware User s Manual 4 Open Internet Explorer Version 6 0 or above and type in the Default IP 192 168 0 100 5 When you see the login window please input default user and password Default User Admin Password 123456 Account admin Password essees Language English Login 6 After logging
9. EDs Connected devices can be activated by Output buttons on the Live View page or through video management software Connect pins 2 and 4 to your Digital Output device The I O terminal pins are numbered left to right Pin 2 12V Digital This pin provides DC 12V power which can be Voltage 12V DC Output connected to Pin 4 via DO devices to complete a Max 1 2W Power Side DO circuit with a maximum current of 100mA Pin 3 Digital Input Connect to GND to activate or leave floating or Must not be exposed to unconnected to deactivate voltages greater than 30V DC Pin 4 Transistor Uses an open collector NPN transistor switch Max load lt 100mA Output that connects to the internal ground to complete Max voltage 24V DC the circuit with Pin 2 If used with an external to the transistor relay a diode must be connected in parallel with the load for protection against transient voltages Available only for device versions with enhancements 9 www acti com pq ACT Connecting Vision ACM 4201 Hardware User s Manual FUSE 1A nee DC TO DC POWER INPUT EARTH GND i sw lt RELAY lt i jOE i O DEVICE O lt E DC POWER Connect input output devices to the camera as follows 1 Attach the cables for the device securely to the supplied green connector block 2 Once the cables are connected push the connector block into the terminal connector also green on the cam
10. Kit Support This IP Camera can be integrated or controlled by applications from third party software developers Software developers can save considerable efforts by using our Streaming Library or ActiveX control Please contact us for details on integration support Digital Time Code Embedded The Digital Time Code Embedded function records video time in the video stream Therefore each image frame is marked with its original recording time It is very useful when users want to find the video at an exact time or between a certain time intervals www acti com ACTI Connecting Vision vA ACM 4201 Hardware User s Manual Safety Instructions Don t use the power supply with other voltages This device is likely to be damaged or damage other equipments personnel if you use a power supply with different voltage than the one included with this device All warranty of this product will be voided in the situations above Don t open the housing of the product Cleaning Disconnect this video product from the power supply before cleaning Attachments Do not use attachments not recommended by the video product manufacturer as they may cause hazards Water and Moisture Do not use this video product near water for example near a bathtub washbowl kitchen sink or laundry tub in a wet basement or near a swimming pool and the like Don t use accessories not recommended by the manufacturer Only install t
11. ably registered trademarks of respective companies Liability Every reasonable care has been taken during the writing of this manual Please inform your local office if you find any inaccuracies or omissions We cannot be held responsible for any typographical or technical errors and reserve the right to make changes to the product and manuals without prior notice FCC CE Regulation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the users will be required to correct the interference at their own expense VVAYAYAYA rol LU Xe aa ACTI Connecting Vision bis ACM 4201 Hardware User s Manual 1 Introduction Package Contents ACM 4201 Power Adaptor Optional Product CD Camera Stand Warranty Card www acti com ACTI Connecting Vision vA ACM 4201 Hardware User s Manual Features and Benefits This is a cutting edge digital video surveillance camera
12. dicator LED light will light up after the Camera has successfully completed the boot process 2 Microphone Input Sensitivity 36dB 3dB OdB 1V Pa at 1KHz S N Ratio More than 58dB Directivity Omni directional 3 Motion Sensor PIR Motion Sensor detects movement by looking at changes in the Infrared IR spectrum Available only for device versions with enhancements 8 www acti com ACTI Connecting Vision vA ACM 4201 Hardware User s Manual 4 Audio Output The IP device supports audio output with earphone jack 5 Ethernet Port The IP device connects to the Ethernet via a standard RJ45 connector Supporting NWAY this IP device can auto detect the speed of local network segment 10Base T 100Base TX Ethernet 6 DV 12V Power Input Connect the power adaptor here if your power input is DC12V 7 Digital Input Output Used in applications like motion detection event triggering time lapse recording alarm notifications etc the I O terminal connector provides the interface to e1 Digital Input An alarm input for connecting devices that can toggle between an open and closed circuit for example PIRs door window contacts glass break detectors etc The device will detect the change in digital input and transmit the signal to video surveillance servers Connect pins 1 and 3 to your Digital Input device 1 transistor output For connecting external devices such as relays and L
13. era 8 Reset Button Step 1 Switch off IP device by disconnecting the power cable Step 2 Press and continue to hold the Reset Button with a sharp tipped object like a pen Step 3 Reconnect the power cable while continuing to hold the reset button The Power LED light will flash on for 3 second first turn off for about 15 seconds flash on for another second and turn off again By this time the reset to default operation is already completed This will take around 20 seconds from power up You may then release the reset button This length of time fluctuates slightly with the environment The Power LED light will come back on and stay on after a few more seconds The unit will start up with factory default settings automatically Restore to Default Power On Complete About 20 Seconds 10 www acti com ACTI Connecting Vision vA ACM 4201 Hardware User s Manual Basic Connections Follow the procedures below to connect the IP device to the respective apparatuses _ If you have a PoE Power over Ethernet supported switch or injector PoE Enabled version only 1 Connect your IP Camera to the Switch Injector by CAT5 or CAT6 cables with RJ45 connector 2 Connect your Switch Injector to PC with another CAT5 CAT6 network cable If your switch does not support PoE and you are powering the camera with power adaptor 1 Connect the power adaptor to IP Camera 2 Connect IP device
14. his device and the power supply in a dry place protected from weather Servicing Do not attempt to service this video product yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel Damage Requiring service Disconnect this video product from the power supply immediately and refer servicing to qualified service personnel under the following conditions 1 When the power supply cord or plug is damaged NO If liquid has been spilled or objects have fallen into the video product ee If the video product has been directly exposed to rain or water Bay If the video product does not operate normally by following the operating Instructions in this manual Adjust only those controls that are covered by the instruction manual as an www acti com 6 ACTI Connecting Vision vA ACM 4201 Hardware User s Manual improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the video product to its normal operation Safety Check Upon completion of any service or repairs to this video product ask the service technician to perform safety checks to determine if the video product Is in proper operating condition www acti com ACTI Connecting Vision vA ACM 4201 Hardware User s Manual Physical description 1 Action LED In