1. Low Resistance Continuity Measurements WARNING Do not run this test unless the voltage on the device under test is zero If the Live Circuit status LED lights when a test is initiated immediately abort the test and check that the circuit under test is not powered 1 Set the Function select switch to the Resistance Q position 2 Connect the red test lead to the LINE input and the black lead to the EARTH input 3 Perform a zero adjustment using the zero adjust screw on the display as described above 4 Connect the test lead tips to the circuit under test and read the resistance on the green display scale The maximum resistance is 50Q The main application for low resistance tests is the identification of low Q circuits such as motor runs and start windings which may differ by only a few ohms With a mid scale reading of 2Q this test mode can also be used to check relay contact resistance AC Voltage Measurements Set the Function select switch to the red ACV 600V position Connect the red test lead to the LINE input and the black test lead to EARTH Connect the test lead tips to the circuit under test PON gt Read the voltage value on the red display scale 6 Model 380353 V1 4 02 05 www burntec com Maintenance Battery Replacement If the red Power Test status LED no longer lights when a test is initiated the eight 1 5 V AA batteries must be replaced Ensure that the meter is not in the test mode and that t
2. C RH 80 max 2 Model 380353 V1 4 02 05 Specifications www burntec com General specifications Display and zero adjust Taut band multi scale analog display with status indicators Live circuit indicator LED lights when live circuit is sensed Withstand voltage Meets IEC 1010 safety requirements for Cat III 600V Power source Eight 8 1 5 AA cells Power consumption Megohmmeter 190mA Continuity 120 mA approx Fuse protection 250V 1A for Insulation Resistance and Continuity Tests Operating conditions 32 to 104 F 0 to 40 C lt 80 RH Dimensions 6 7 x 6 5 x 3 6 170 x 165 x 92mm Weight 2 1 Ibs 970g Standards CE Low Resistance Range Accuracy Overload Protect 0 to 50Q 5 of reading 250V Open Circuit V approx 600mV Short circuit A approx 240mA AC Voltage Range Accuracy Line Frequency 600VAC 5 of full scale 40Hz to 1kHz Insulation Resistance Megohmmeter Voltage 10 Range Accuracy 250VDC 0 to 50MQ 500VDC 0 to 100MQ 5 of reading 1000VDC 0 to 400MQ Short circuit current 2mA Overload Protection 250V Model 380353 V1 4 02 05 Meter Description www burntec com Analog Display 2 Live Circuit status LED Pointer zero adjustment screw 4 Power Test status LED 5 TEST pushbutton with Lock function
3. 1 890 7440 Tech support Ext 200 Email support extech com Repair Returns Ext 210 Email repair extech com Website www extech com Copyright 2005 Extech Instruments Corporation All rights reserved including the right of reproduction in whole or in part in any form 7 Model 380353 V1 4 02 05
4. 6 Function select switch 7 Battery Fuse compartment on rear 8 Test lead EARTH input jack 9 Test lead LINE input jack 10 Test lead storage compartment Analog Scale Description 1 Black Megohmmeter Scale Multiply reading by 0 5 for 250V range 1 500V 2 1000V 2 Red AC Voltage Measurement Scale 0 to 600V 3 Green Low Resistance Scale 0 to 50Q MQ 1 100 20 1 ZI 05 0 200 ACY 400 i oS e 800 2 1 3 a 5 E meee Model 380353 V1 4 02 05 Operation www burntec com CAUTIONS A Observe all safety precautions when the FUNCTION switch is set to either the 100MQ 500V or the 400MQ 1000V position A Connect the meter test leads to the circuit under test before operating the TEST switch A Do not touch the clip ends of the test leads when the TEST switch is pressed Some electrical equipment especially cables may retain an electrical charge when disconnected from the line It is good practice to discharge such equipment with A grounding straps or other suitable devices before touching or making connections The meter automatically discharges the test circuits when the spring loaded TEST switch is released IMPORTANT NOTE Remove all power to the circuit under test when making resistance measurements If A any voltage is present in the test circuit the red on the meter scale plate will light Immediately disconnect test leads an
5. d turn off power to test circuit Function switch The FUNCTION switch is a five position rotary switch and is used to select the desired range or function Test switch The TEST switch is normally OFF It is a spring loaded momentary action for safety The test voltage generated by the meter is automatically discharged when the TEST switch is released Connecting Test Leads For all functions connect the red test lead to the LINE terminal and the black lead to the EARTH terminal Test Lead Check Set the rotary switch to the low resistance position Q Connect the leads to the meter and short the clip ends of the test leads and read the green resistance scale on the display Depress the TEST switch and the resistance should read between 0 and 0 5 Q The display should read maximum range with the leads open not shorted If any readings are obtained other than the readings just described the test leads should be considered faulty and must be replaced before using the meter Failure to do so could result in damage to equipment and electrical shock Live Circuit Status LED If the Live Circuit status LED is lit voltage is present on the device under test DO NOT proceed to test with voltage present Shock to the user and damage to the meter or device under test can result if testing is done with voltage present Proceed with testing only when the voltage is removed from the device under test Power Test Status LED When the meter is actively t
6. esting the Power Test status LED will blink When this status LED is flashing DO NOT touch the test leads or any exposed parts in the testing area Hazardous voltages exist that can cause shock If the Power Test LED fails to light the batteries must be replaced Refer to the Maintenance section near the end of this manual Mechanical zero adjust The pointer should indicate zero on the green 50Q scale when the FUNCTION switch is in the Q position when the test leads are shorted together and when the TEST switch is depressed If the pointer does not indicate zero adjust the white plastic mechanical zero screw located on the lens cover 5 Model 380353 V1 4 02 05 Megohm Measurements www burntec com 1 Disconnect all power from the circuit to be tested 2 Set the FUNCTION switch to the desired test range 3 Connect the alligator clips to the circuit to be tested CAUTION If the LIVE CIRCUIT indicator lights up at this point DO NOT operate the test button Remove the alligator clips and disconnect all power from the circuit 4 Press and hold the PRESS TO TEST button to make the measurement Turn the button turn to the right to lock the test on 5 Read the value on the MQ scale and apply the range multiplier to determine the Megohm resistance reading 6 Release the PRESS TO TEST button and allow the device to discharge before removing the alligator clips Range Reading Multiplier 250V 0 5 500V 1 1000V
7. he test leads aren t connected Remove the Phillips head screw on the rear battery compartment cover Remove the battery compartment cover Replace the eight AA batteries ensuring proper polarity or oO NS Affix the rear cover and secure the rear screw Fuse Replacements To test for an open fuse first assure that the batteries are not defective and then proceed as follows Connect the test leads to the meter and short the clip ends of the test leads Set the function switch to the ohms position and press the TEST button If the fuse is open blown the pointer will indicate an open circuit max resistance oN To locate the fuse open the rear battery fuse compartment via the Phillips head screw located at the center of the meter case 5 Replace the fuse 250V 1A fast blow located in the battery fuse compartment just above and to the right of the batteries Secure the battery fuse cover Cleaning Periodically wipe the case with a dry cloth Do not use solvents or abrasives Do not allow water to seep into the meter case Calibration and Repair Services Extech offers complete repair and calibration services for all of the products we sell For periodic calibration NIST certification on most products or repair of any Extech product call customer service for details on services available Extech recommends that calibration be performed on an annual basis to ensure calibration integrity DN Support Hotline 78
8. inclusive and no other warranty whether written or oral is expressed or implied Introduction Congratulations on your purchase of Extech s High Voltage Megohmmeter This meter is geared toward high voltage insulation testing applications such as appliance testing In addition to Megohmmeter Insulation Resistance measurements low resistance and AC Voltage can be measured This professional meter with proper care will provide years of safe reliable service Safety 1 Circuits under test must be de energized and isolated before connections are made except for voltage measurements 2 Circuit connections must not be touched during a test Use extreme caution when working near bare conductors and bus bars Accidental contact with conductor could result in electrical shock 3 Use caution when working near voltages above 60VDC or 30VACrms 4 After insulation tests capacitors must be discharged 5 Test leads including alligator clips must be in good working order clean and without broken or cracked insulation 6 When servicing use only specified replacement parts International Safety Symbols Caution refer to this manual before using this meter Dangerous Voltages Meter is protected throughout by double or reinforced insulation Rated Environmental Conditions e Indoor use only e Installation Category III e Pollution degree 2 e Altitude up to 2000 meters e Ambient conditions Temperature 32 to 104 F 0 to 40
9. www burntec com User s Manual EXT INSTRUMENTS High Voltage Megohmmeter Analog Insulation Tester plus AC Voltage and Continuity Tests Model 380353 EXTECH 380353 HIGH VOLTAGE MEGOHMMETER www burntec com Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment a six month limited warranty applies on sensors and cables If it should become necessary to return the instrument for service during or beyond the warranty period contact the Customer Service Department at 781 890 7440 ext 210 for authorization or visit our website at www extech com click on Contact Extech and go to Service Department to request an RA number A Return Authorization RA number must be issued before any product is returned to Extech The sender is responsible for shipping charges freight insurance and proper packaging to prevent damage in transit This warranty does not apply to defects resulting from action of the user such as misuse improper wiring operation outside of specification improper maintenance or repair or unauthorized modification Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct indirect incidental or consequential damages Extech s total liability is limited to repair or replacement of the product The warranty set forth above is